RUBBLE OR B Concrete drain

ROCKFILL TRENCH fall 1:25


TO OUTFALL length 5m 1800
100 100
230 300 741 300 230 300 800 800 300

300
5 5

100
RUBBLE OR ROCKFILL TRENCH

300
RUBBLE OR ROCKFILL TRENCH
6 FOR DETAILS SEE 4 TAP CWP TO OUTFALL

100
3 3
4

100

FALL 1:40
150

100
CONNECTION TO

800
MAINLINE FALL 1:40

1600

150

200
200
CONNECTION TO MAIN LINE

250
250
1 10%

100
A A
3 5% 150 150
FALL 1:40 FALL 1:40 2

550
9
SECTION A-A
Scale 1:25

100

100 150 100


RUBBLE OR
300

ROCKFILL TRENCH
TO OUTFALL
2400

300
B
PLAN 4 TAP CWP
2400
Scale 1:25
5 PLAN 2 TAP CWP
6
LIST OF MATERIALS Scale 1:25
PIPES AND PIPE FITTINGS 100
5000 4
4 TAP CWP 2 TAP CWP

50
1 25MM DIA GS PIPE 25M 1 25MM DIA GS PIPE 15M REVISIONS
2 50-25 MM HEX BUSH 1 No. 2 50-25 MM HEX BUSH 1NO 30-7-86 rubble trench
3 50MM DIAGS ELBOW 3 No.s 3 50MM DIAGS ELBOW 1 NO
4 50MM DIA GS PIPE 3.5m 4 50MM DIA GS PIPE 1M 5%
REFERENCES
5 19MM DIA BRASS BIB COCK 4NOs 5 19MM DIA BRASS BIB COCK 2 Nos SECTION B-B B 1574A Type Rural community W/points ( in metric)
300
50-19 MM REDUCING 50-19 MM REDUCING Scale 1:25 C 1708 TYPE HUMAN w/POINT- rural areas
6 SOCKET 4 Nos 6 SOCKET 2 Nos
B 1574 Type Rural community W/points ( in feet)
8 50MM DIA GS CROSS 2NOS 7 50MM DIA EQUAL TEEE 1NO
9 50MM DIA GS CAP 1 NO.
25MM DIA GATE VALVE AT 25MM DIA GATE VALVE AT MINISTRY OF WATER &
THE CONNECTION TO THE THE CONNECTION TO THE 7
10 MAIN OR STORAGE TANK 1NO 10 MAIN OR STORAGE TANK 1NO
5
IRRIGATION- MAJI HOUSE
ALL GS PIPES CLASS B 6

495
BUILDING MATERIALS 4 100 COMMUNAL WATER POINT
ROCK OR RUBBLE FILL 1.5M3 100 800 800

CONCRETE CLASS D 1M3 50

100
200 DRAFT BY STIG HEDLUND APRIL 1974 SHEET 1 OF 1

TRACED BY SAUL E. EGALA AUG 1974 SCALE: AS SHOWN


250

SECTION C-C DIGITIZED


NOTE: RUBBLE AND ROCKFILL HALL BE PLACED ON 50MM SAND/GRAVEL LAYER H.K. NJERI JAN 2010 DRG. NO.
1 2
3 Scale 1:25
CHECKED ENG. B.I M.W.I
ALL VOIDS BETWEEN ROCKS SHALL BE FILLED BY SAND 300 KASABULI JAN 2010
APPROVED D.W.S JUNE 2010 018-TYPE-006A