You are on page 1of 3
BRAKE POWER CERTIFICATE FOR PREMIUM RAKE : brake systems [conv.tescortsemes) as | Keo | 25 e011 ‘TOTAL KBD BMBS % | «167% a8 fen (uence ISSUED BY (ExamPoint/Division/RW) amar / 8°C No. castes waz amr"? fear ap ere area THs BPC is valid for 12 daysie. upto NKi (New Katni Yard)iJBPWCR 50000624202 01-02-2024 (Twin Pipe Rake ) 28012 ate, ca enc AL aga a8 ¢ Rare er aA aA, DFR ce Te g_RO DIE) [After this date NO FRESH LOADING IS PERMITTED. (5 days grace period after this date is allowed for rakes loaded upto above date) ‘wont /Rake id —-_DYDY010223120807 fete /oate 20-01-2024 YeowrAH/Rake Name PM48112 ‘easitsnfea snégirois ip“ DYD¥010223120807 ‘opt aac Train No. NIBOX 513 2. sate / Loco No. 41515 3s angi zeen/ Load & Stock 60 4. gern ets / Total No. of Bk. Cys 119 5.cprlaadofirsz/ No.of Operating Cyls 113 6. acpuraans /Brake Power % 94.96 Teagan grater zaet / Engine on Train (Time) 20:00:00 Beary targa erat / Al Pressure ready at 20:30:00 Ai ressure on Departure BRACE RGA | PRE RSGI SPe e rates) aan /Inlocomotive 50 0 dota /in Brake Van 47 57 4 tlamtteteparage / LIST OF WAGONS IN ORDER SNo. | Wagon(owner/Number/Type) | S.No. | Wagan{Owner/Number/Type) __|'S\No. | Wagon(Owner/Number/Type) 7 | SER ROTISTAISE SONAL Ta | SER BBORREOTER BONA a | Bea SEAT BONA Z| SER ZEOGE2IGTE BORNAL [5_ | NRZAOSETT ESS BORN ERR ZT TSTORZ BORN 3 NAR DET TOSTTASA BOREL Je [BER 2S07GBS100 BORNR i [BER FROTOTATOOE BORNASIT-1OP 7] SER TROTTED BORN TI | WOR ABTESTOTS BORN | SER TE ATRESAE BORNTSNT 5 | ECR TATORZTTOS BORROW ZE__ | NOR T2TOOTSGEBS BONS ‘B__ [WOR T2T07SO8GS BORN 3 [BWR ORTSTOETIES BORNAL 7e__ | EGR 2501920607 BORNAC BE | NOR BETH STRAAT BORN 7 [ECR RETTTORATIE BON IO| EGR TETOOS TOTO BORNASIT | Co ATOSTETS BON 3 | SER 22007355071 BORNAL Ti | SEGA 22177 7a008 BOXNAL = R ZEAE BONA I | ECOR DET AOSESSTE BORN 2 WR DADSDOTETTS BORN TO™ 35 RR TONES TSS BORN 7a | SW TTSOESDEOT BORN _ | SEGA T2TAGMOISS BOXNR-10P | 58 SR ZETASTOSTT BORN Ti NOR 22730065176 SORNAL 3a | SER 1007GOS0507 BORNR 7 FR TOaDIOEEBE BORNASITT TL EGR OTST SATE BORN TE | NOR TEAS SOUZE BONN | EGR TE TOUS BORNE 73 | EGR THOO034708 BONEN 3e__ [SEGA B2TATATHTAS BORNE a [ECOR BEITSTIIGS BORN Ta | SEOR EASES BORN Ti | BER TOOTSRSRISE DORRIT BO [ROR aT STOTOaRT OVE 75 __ | ECR 2ETOTTSa7 BORNE TE | ECoR ZETaISIRHGT BORNAL 75 __ | SEGR 2210657855 BOXNAL Bo | EoR DeFaTRTOEH BORA 17 | WOR TaTOOESTOS BORNE | ECR DETAR BORN TE | SER OTORERTIS BORN Ti | SEGA 22aT2EOOTS BORNE Te | WOR RETRO BORN TE ECR DA TOSTTT BORAT __ [NR REORDOTI TOS BORN @__ | Ear TAT O0TGEED BORNW | SER T007OTSZAGT BORN za wR Tan GOERS BONN Z| SER PROSTATE BOL TS ECR TAT OT TERE BORN | SER Pa2ITGTES BORNAL 7 | SER ZBORTSTTTET BORNAL RAVI SHANKAR RAKESH KR UTTAM SHUKLA Fragen Instructions Bo watant aaa GUARDS AND LOCO PILOTS are ware A vest are a rear ahaa Be Before starting the train, guard and driver shoulé ensure Sb rae a fg a gah a eae a ae ree eae aT aaa No loco pilot move the loaded train from the loading point unless the destination is clearly mentioned on the Brake Power Certificate. (reece arrien gear, qe rs a a a, ae ah es ero a eT TT aT sits act agar i ia a arf sft After each loading unloading pont, before starting Loco pilot, Guard ‘and station staff shall ensure that BPC is valid. The train should be subjected to GDR check as per Check lst. (i) rand ite ta Tag ca ATT Continuity of air pressure from first to last vehicle of the train. iy) abe dewey ater arta rata fre a ae ot emg fare ff PR oT If BPC is inva, inform the Contol Office and take necessary instruction from CBW controll. (ae etree ete rare rere ato a a Pa ie ate are, a safer rant eons ct ai ot eae aM ‘The incoming Loco Pilot shall hand over the brake power Cetticate to relieving Loco Pit. Ihe i leaving the tain without reli, it shall be deposited wit the nominated authority who wil give it tothe out going Loco Pio. (iy Pete eh ee sc adapta a age age ae gc ve i ee Ts aa eT ‘The outgoing Loco Pilot and Guard wil sts themselves from the listed Wagon Nos.that the brake power cartficate pertains to thei tran, aft eB atta Fe 8 paren aa ae ae Te ae rt 1 24 92 8 fine Ba eer are Ht ea at Peat AT This certificate is valid: 1 Provided the composition ofthe rake is not changed by 4 or more wagons. 12 Provided the rake is not stabled for more than 24 hours in train Examination Yard. CC. ard ote great arc fae ae fatter ate fatter a faaen (aigtare TH) DETAILS OF CONTINUITY AND CHECKS CARRIED QUT BY GUARD AND DRIVER (GDR CHECKS) ait | fae | ar | geaaamateena | afaammdga: | Surana seu air S.No. | DATE | Station | DRIVER'S NAME & SIGN. | GUARD'S NAME & SIGN ane a gee SMIDY. SS NAME & SIGN D0 Bete ratanfiett rer atte ere ar ard ats ere rede Peaear aera tee BRAKE CONTINUITY/REVALIDATION AT LOADING POINTS(OR THEIR NEAREST EXAMINATION POINTS BY TRAIN EXAMINING STAFF aan | fete | Sat | tar aet War aar eae aaTaeT eae S.No. | DATE | Station | RAILWAY | LOCONo. | PRREADY AT | ABNORMALITY SIGN OBSERVED Emre as Fa ae ar a Fae (are abe grea aT wT ATA) PARTICULARS OF WAGONS DETACHEDIATTACHED ENROUTE (To be filed by Guard & Loco Pilot) TF ae aot wea a Pare | maT an aT Pane 1 Pea SNo. Wagons Detached Station & Date | S.No. Wagons Attached Station & Date fr ir bk k he be FL ante arent Praeer LOADINGIUNLOADING DETAILS. eet Pai Sort Raia Station Date Station Date ist [Destination Loading land [Destination Loading ye Destination Loading Gs ore wareat ea rare ENROUTE PROBLEMS NOTICED & ATTENTION GIVEN ‘feare aaa. aa aa] aaret rarer latrat arate feere Bra Date | Loco No. ware Problems & Action taken ‘Sign. of LP/Station Staff lLoco Pilots's Name Ha SariStaion TaNature

You might also like