You are on page 1of 6
ARC Brasov SO saree = LABORATOR DE METROLOGIE LS Svar Certificat de etalonare nr. 8084 beet rr eerie Calibration certificate Marca de etalonare _[6084-11.23] Calibration mark RENAR LE 031 05.2023 (Obiect MULTIMETRU object Acost cortitcat de etalonare Jdocumenteazé trasabiltatea rezuitatelr prezentate la Sisterul Producator PEATE international de Uniti (S). Manufacturer Trasabiltatea masuranior este roakzata $i menfinuta prin etalonari Jperiodice, in conformitate cu SR Tip Pea eceney JEN ISO/GEI 17026:2018. Type Inceritudinea standard do masurare a fost determinata in 5 conformitate cu EA 4-02.Esto 8928 Serie 10028 ecomandat ca utitzatorul s& Serial number lasigure reetelonarea a intervale Je timp rezonabile (Client GIGATEGH SYSTEMS SRL Nr [Customer B-dul 1 Mai Nr.5 CRAIOVA ieee ois documents tho traceabitty results Comanda nr. 2038/08.11.2028 to tho intemational System of Units ae (S).The measurement traceabiy aoe is achioved and maintained by eriodically calbretion, Numéar de pagini é leccoraingto SR EN ISO/CE! are 17025:2018. The standard Nama caved certainty of moasurement has been determined according to EA Data etalonarit 09.17.2023, 4-02. itis recommended to the Eapapereorin user to assure the recalibration at reasonable time intervals. oid Ace cecal de ealonare na post froprodu dectin fotalate, Coricatul de ealonere fr semnatr samp nest vali Note: This cabratoncerfiate may nthe reproduced other than infu. Caliaon catteste without signatures and seals nt va Executant etalonare Person performing the calibration ‘Stampila Data Seal sero Data of issue ge) | at Se) Fomular cod F04PP05 £8. 0.0 Sef laborator Head laboratory 09.11.2023 —_-Rotaru Dragos ee \aboratar de metoiogie, Sr Friant N17 Brasov 500482 Tet 0268-47257, 0268-307926; Fax 0268-41979 Danie! Tohaneanu wn arr, nal: mevologie@are 0 LABORATOR DE METROLOGIE Certificat de etalonare nr. 8084 Pag. 2/6 Pages 20f Descriere obiect JObject description Valoare nominala/ interval de masurare: MULTIMETRU 1000 Vee; 1000 Vea f= 50 Hz; 10 Acc; 10 Aca f=50 Hz; 2000 MQ: Exactitate/clasa/referential Conform documentatiei tehnice Starea obiectului E [Alte informatit z Metoda de etalonare Comparare directa conform procedurii PE-O1 Etaionarea mulimetrelor {Calibration metod digitale Etalonul utilizat / nr. CE | Measurement standard Calibrator tip MEATEST M-142IR, serie 641631, CE 1313/27.01.2023 amie] de ARC BRASOV Locul etalonarii Place used for calibration Laborator de metrologie ARC Brasov Conditii de masurare Thainte de etaionare aparatul a fost menfinul in laborator timp de 24 ore Pentru a intra in echilibru termic. \Conditii de mediu Measurement condition Temperatura 2°C£2C ‘Conditii de referinté iene [Reference environmental conditions Umiditate relativa < 75% tensiune Temperatura (2382)°C rezistenta Umiditate relativa <60% rezistenta Temperatura (22,740,2)°C ...(22,780,2)'0 tensiune Environmental conditions Umiditate relativa (35,242,5)% ... (34,842,5)% tensiune Temperatura (22,740,2)°C.... (22,640,2)°C rezistenta Umiditate relativa (34,842,5)% ...(35,842,5)% rezistenta Reglarea obiectului ‘Aparatul nu a sufenit ajustan. instrument adjustment Informatii suplimentare Es Additional informations Rezultatele etalonarii : [Calibration results Formula cod FOUPP-05 Ed. re. 0 Executant etalonare Person performing the calibration Ta ee Dani LABORATOR DE METROLOGIE Pag. 3/6 Certificat de etalonare nr. 8084 Pages 30f6 Rezultatele etalonarii Calibration results Tensiune ce Domeniu | Valoare medie | Valoare de | Incertitudine de indicat refering | Froare masurare Range | Mean indicated |Reference Value} Error Uncertainty value [ev [nv] Tv] Tv] 739) 20.0 O71 29.9 700.0 04 oe 780.0 780.0 On “78,7 =180,0 os M M M 0,198 0,200 x 0,198 0,200 0,001 0589 0,600 0,007 2 0.998 7,000 0,007 7,388 1.400 0,007 71,738 7,800 0,007 “1796 “1,800 0,004 7,99 2,00 3.98 70,00 a 77.98 18,00 “17.94 18,00 oo) 20.0 29.9 100.0 a 773.9 780,0 “1738 “180.0 04 % 700) xt 99 500 za soe 399) 900) =i 898 2007 2 Tensiune ca f=50 Hz Domeniu | Valoare medie | Valoarede | ;,..,, | _ Ineerlitudine de nominal indicat referinta foal masurare Range | Mean indicated |Reference Value| Error Uncertainty value [nv] [nv] [nv] ey [nv] 199 20.0 “Or Ot 200 700.0 70,0 00 02 780.2 70,0 02 as Executant etalonare Person performing the calibration Daniel Tohaneanu. Formula cod FOUPP-08 Ed. ro LABORATOR DE METROLOGIE Certificat de etalonare nr. 8084 Pag. 4/6 Poges40f6 M M iw 0,200 0,007 0,007 0,600 0,007 0,007 2 7,000 7,000 0,000. 0,001 1,400 1,400 0,000 0,007 7,802 7,800 0,002 0,007 1,99 2,00 0,01 20 3,99 70,00 0.07 78,00 78,00 0.07 19,9 20.0 7 200 100,0 100,0 07 180,2 180,0 Ot 96 700 1 1000 499 ‘500 7 900 ‘900 7 Curent cc Domeniu | Valoare medie Valoare de Ean Incertitudine de nominal indicat referinté masurare Range | Mean indicated |Reference Value| Error Uncertainty value Al imal mA] ima] Tm Sit Soe et Sot 2 0,999 1,000 0,007 0,007 1,798 1,800 0,002 0,007 785. 71,800 0,005 0,007 7.98 2,00 0,07 0,01 20 3.97 70,00 “0.05 0.01 17,95 18,00 0,05 0,07 19,9 20.0 01 200 99,7 700.0 OT 179.5 780,0 Out iI TA) Al Tay 0.99 7,00 0.01 10 4,95 5,00 0,07 8,93 9,00 0,07 Formula od FOUPP-05 £4. ro. 0 Executant etalonare Person performing the calibration ga LABORATOR DE METROLOG! Certificat de etalonare nr. 808 IE 4, Pag. 5/6 Pages of 6 Curent ca f=50 Hz Domeniu | Valoare medic] Valoarede | ¢0,,, | _incertitudine de nominal | indicat referinta masurare Range | Mean indicated |Reference Value| Error Uncertainty value mA] “mA imal [Al imal 0,198 0,200_| 0,002 0,004 2 0,998 7,000 | 0,00 0,007 7,800 7,800 0,000 0,008 798 2,00 0,02 0.07 20 297 70,00 0,03 0.07 17.97 78,00 0,03 0.05) 78.9 20.0 Ot Ot 200 98,7 700.0 O5 on 779.5 780.0 02 08 rT (Al fl Al (al Kd 1,00 005 O,0T 10 4.95 5,00 “0,055 0,02 3.95 9,00 “0.07 0.02 Rezistenta electrica Domeniu | Valoare medio] Valoarede |; 0.7, | _ incertitudine de nominal | indicata referinta masurare Rango | Mean incicated |Reference Value| Error Uncertainty value {9} {0} {9} {2} {a} 01 0,0 01 0.1 ay 700.0 700.07 00) 0.4 a Tia Tha] Tha 3 0,200 0,200 0,000 0,007 7,002 7,000) 0,002 0,001 a 2,00 0,00) 0,07 70,01 O07 0,07 20,0 00. 0,1 fd F007 02 0.1 [aay [1] [Mo] ima] 5 0,200 0,000 0,001 7,000) 0,000 0,007 = 2,00) 0,00 0,07 70,00 0.00 0.07 2000 796 3 z Executant etalonare Formula cod FOUPP.05 E41 0.0 Person performing the calibration ga LABORATOR DE METROLOGIE Pag. 6/6 Certificat de etalonare nr. 8084 Poses 6of6 ncertitudinea de masurare —_ Incertiudinea deciaraté este incerltudines extnea Ob|nula prin ‘multipicarea incertitudinii standard a masurarii cu factorul de acoperire k =| 2 care, pentru o distributie normal, corespunde la un nivel de incredere de aproximativ 95% Measurement uncertainty The uncertainty is the expanded uncertainty obtained by multiplying the standard uncertainty of measurement by the coverage factor k = 2, fora normal distribution, Corespond to.a degree of reliability of aproximately 95%. Conformitatea cu o specificatie: - Compliance with a spectication Not&: Rezultatele etalonairi se refera numai la obiectul elalonat [Note: The calibration result refers only to the object to be calibrated. Executant etalonare Person performing the calibration Danie! Tohaneanu. Incheierea certificatului de etalonare End of calibration certificate Fomular cos FOUPP-05 Edt rx.

You might also like