You are on page 1of 27
CCSI S=—\—— FACTORY ACCEPTANCE TEST REPORT O7/FATR/APL/06-02-2024 Today, Tuesday February 06, 2024 at PT. Communication Cable Systems Indonesia Tbk factory in Cilegon, a factory acceptance test has been conducted to optical fibre cables of PT. Communication Cable Systems Indonesia Tbk ordered by PT KA Properti Manajemen With PO Number 007/PO- APL/1/2024 dated 26 January 2024 Project Name “KAI Ciawi - Banjar” The inspected cables were ‘% Duct 12 Fiber Single Mode G652.D No | LengthNo | DrumNo | WO.No Test Item 1 | LN 149404 | 015-5935 9105 Attenuation Test PASS Duct 48 Fiber Single Mode G652.D No| LengthNo | DrumNo | WO.No Test Item Result Tensile, Crush, Repeated Bending, 1 | LN 149407 | D16-5916 9105 | Impact, Torsion, Kink, Design, Water | PASS Penetration Test Cable lena! Duct 12 Fiber Single Mode G652.D, 9,212 m in 3 drums for WO 9105 “ Duct 48 Fiber Single Mode G652.D 67,237 m in 17 drums for WO 9105 Inspection has been done following to a sampling method and in according to the procedure and specifications of related contract and had been witnessed by PT KA Properti Manajemen representatives. Inspection test results are in the attachment. * All parties have agreed to declare that all the cables were “PASSED” to the tests and were ready for Aris Page 1 of CCSI Cilegon, 06 February 2024 PT. COMMUNICATION CABLE SYSTEMS INDONESIA Tbk Witnessed by — Goa Sign 1 Dimes Pr Anogeran Power (estari Oh 2 Gey SV\eivane RY. AY Aad - 2 Ghye Or. RA VES 4 Arto Supstyo.R PT EAPAN AG 5. MSep Sole oe Sr. atm RD 6 Naroho Presety o> | PT: fap - Agebn 7. 8. . - 10. Page 2 of aocsl Subject Factory Acceptance Test (FAT) Customer PT. KA Properti Manajemen Project Name: ‘KAI Ciawi-Banjar Venue COSI Tbk Factory Cilegon Date February 6, 2023 Company | Title Phone No. E-Mail Address Signature 1] Ceceg Gg wm. EA bat Penn 1 Kate QT FARA PT.APL PT. APL mh \erem br cosy BE OBIZRE 2156 6r OSussros Ty O 6 13G205 [203 of Io 1% OPP SIP HIN, CCSI Attenuation test Cable Name Duct 12 Fiber Single Mode G652.D Wo. Number WO 9105 Customer PT. KAProperti Manajemen Drum No| DiS- $445 Project Name [KAI Ciawi-Banjar Length No| (44404 | Test according to 1Ec-60793-1-40 Test Apparatus EXFOFTB....230, Tost Specification 0.35 dBikm at 1310 nm 0.20 dBikm at 1550 nm Measuring Wavelength = 1310 nm & 1550.nm No. of measured fibers. 6 fibers/Tube Test Result ‘Attenuation (dB/km) [o7) Bue (08) Orange (08) Green Length Number ayy Optical Length 4.134 inet This cable has passed the test : yes / Remarks QC-Inspector, PT. CCS indonesia Tbk ip (AM Fa Date : 06 -o2- ow, Page 1 of 1 FIBER_001.trc (1550 nm) OTDR report FIBER_003.tre (1550 nm) « | | “ | | x % rs | | 000 en aod abo abo ita ead som || | = FIBER_007.tre (1310 nm) ar sa) | | | 350 4 | | i | c {| 1 "a | | | . 7 7 mS 7 z 3 ? tm Eates a a te Ln ee cae z oe | ,__ FIBER_002.tre (1850 nm) ~ — FIBER _004.tre (1550 nm) 1 “ 9.0 | solr | Sag? | x 4 | | | 3m 4 | : eS: | 2 ‘ | 220% ‘ i | ‘3. | 20 | . ) ) "se °° 35S ~T055 F850 BIND BaHO 30RD OSD ADDO A500 —m 900355 Son 1500 2000 BELO BROOD 4800 pert Ghveewe | | tte et Pe opine 388m Sen OR Shae Segre Glatt Smee ae a FIBER_002.trc (1310 nm) 1 Pw ‘FIBER_004.tre (1310 nm) — a ) | am | 4s « | | 8 . ;|° : : Sfantrgm Liszt ies || Site ia See. UNS aoe | OTDR report a FIBER_005.trc (1550 nm) Wo tie 18002000 2800 3000 SBoD adoO 4500 m | eis, se sn | okt, men = | fitembe ieee et a Sanies sete Stem fara | | r = FIBER_007.trc (1310 nm) | 008 || is ] | | 8 | | ® | 2000) ‘ | | ‘ | | s | co 7 z 7 7 = | 7 Z 3 7 mm | ‘Senn IS (eerie |) Sle TES Soe Rengebss —£330%8hm Soda Fe || Reaetts 0332 tim Seonre | ~ FIBER_008.tre (1850 nm) —— | | ‘ | 4, 1 | z | 7 } | | | 1 | eee |e eee | Siiicum issn Shien | Se. oem time Seeoee | Ree Soe ine SE. Siete Se" Binwe | | ge FIBER 006.tre (1310 nm) ce FIBER_008.tre (1310 nm) |) Soo)” | Ss | | 8 Sf | 4 | « 1 | } | 90 1 | | z 7 T = 2 7 ¥ T 7 | | eens Serrengm Latin ioe Sr oe | Sa" Gye Soe Se Soe Bg ~ FIBER_009.tre (1550 nm) OTDR report FIBER_014.tre (1550 nm) oe | « ] so n.00f | seam : | 3 ; | | x {| | 2 ae | 8 ‘ | jis | ‘09 | |) 9 1 | : Tho Wes 1650 BOD BED SOG BE aH] sO mS ‘so 1000 1800 2000 2800 3000 3600 4000 4500 m Em Ee is ce seas ER" Gee | | oe FIBER_009.tre (1310 nm) — 11.tre (1310 nm) “ | san)” « | A | a | io i | 7 7 B y 7 3 3 7 en senna ieee sein, sp tenis | Rangole 338c0m enon Ream 8358 Sonar ona = FIBER_012.tre (1550 nm) 2o bn ‘ 35 7 ho 1600 1650 BEG abo 3600 —SEbD abo som IBER_010.trc (1310 nm) ] hy | 4 | |) ‘ | | || ie | 1 | (2 4 | | Lz 1 || 2 o im . 7 = 3 a km mgm ae 2c om jee Se“ ce fare, itz. Se fine [CSI Cable Name ‘Customer [Duct 48 Fiber Single Mode Fiber PT. KA Properti = Project Name KAI Ciawi-Banjar Test accoraing to Test Apparatus Test Specification Measuring wavelength No. of measured fibers This cable has passed the test : QC-Inspector, PT. CCS Indonesia Tok, Date: Of = 82 “a4 EC-60794-1-2-3 Crush tester, OTDR EXFO FTB...2£2, Force = 450 kg / 4500 N Time = 10 minutes Relax time = 20 seconds Length = 100 mm Additional loss after test < 0.05 d8/km 1550 nm 8 Fibers, 1 fiber each tube = Before Test (dBikm) [Aer Test (dB/km) at 1850 nm _ at 1550 nm yes /no- _ Reference value contains splicing value Wo. Number Drum No Length No ‘Change (aa/km) at 1850 nm OTDR report Job info sob 1D wo 9105 Reason Contractor Operator A Donny § Customer PT. KA Propert Manajemen Operator 8 Test dete 96/02/2024 (10:10:32 GMT+7:00) File Before Crush D14-5916.tre —— link measurements Span loss 6.17 68 ‘Avg splice loss Span length 38.4732 km Max. spice loss ‘Average loss 0.185 dBi Span ORL 310208 ‘OTOR trace ra 0.00} 2 : < ‘0 5 cel 5 % % % % e % “m = Events table — No Loc. Event ype Loss | Ret at | cum (hen) (8) | 8) | (@a%m | a) 1 0.0000 | Launch Level : 458 2.000 ber Section (93.4732 km) sim o1ss | 6.17 2 334732 | Reflecive Faut “| 300 8177 Testand cable setup Wavelenath 1850 nm (SM-9um) ‘Acq. time 5s Filename Before Crush D14-5916.re Pulse with 27508 Haraware MAX7300-SM1-EA Helix factor 0.00% Serial number isit9t2 Spice loss threshold: 0.10048 Sofware NA Reflectance threshold = -85.0 8 Range 40,0000 km End-oFfbertveshold 1000 d8 1oR 1.468200 RBS, 82.00 OTDR report Job into Job 1D wo 8105 feason Contractor Operator A Donny $ Customer PT. KA Properti Manajemen Operator B Test date (6/02/2024 (10:11:37 GMT+7-00) File After Crush 014-6916.te = Link measurements — Span loss 6.176 48 ‘Avg. splice loss Span tength 33.4719 km Max spice loss : ‘Average loss 0.185 ake Span ORL 30.99.48 OTDR trace « % sooof > 2% . « 15.0 5 5 oa 7% % % w = ™ Events table ~ No Loe Event type toss | Ret. at | cumat (em) 3) | 8) | (@BAm) | (8) 1 0.0000 | Launch Level | = 458 0.000 Fiber Section (83.4719 km) 6178 ores | 8.178 2 | _ssazta_| Reflective Faut - 296 8.178 Test and cable setup Wavelength 1550 nm (SM-9pm) ‘cg. me t2min36s Filename ‘Alter Crush 014-5916.te Pulse wth 275s Hardware MAX.7300-SML-EA Helix factor 0.00 % Serial number asti912 Splice loss tweshold 0.100 68 Sofware NIA Refectance threshold: -55.0dB Range 40,0000 km End-offber threshold: 1.000 d8 ok 1.488200 RBS 82.00 a7 9 Cable Name Duct 48 Fiber Si ‘Wo. Number [WO 9105 Customer PT. KA Properti Manajemen DrumNo. [pi4-Sglb Project Name KAI Clawi-Banjar LengtnNo | ASAT Test according to + IEC-60794-1-2-E4 Tost Apparass Impact tester, OTDR EXFO FTE... 20, Test Specification: Weight = 65 kg Impact Energy = 12 Nm Height = 185 mm Count = 3 times at 5 locations. Time of relax = 10 seconds ‘Additional oss after test < 0.05 dBvkm ‘Measuring wavelength: 1850 nm No. of measured fibers: 8 Fibers, 1 fiber each tube Before Test (dB/km) | After Test (dB/km)] Change (dB/km) at 1550 nm at 1550 nm at 1550 nm This cable has passed the test : yes /96- Remarks: Reference value contains splicing value QC-Inspector, PT. CCS Indonesia Tok Conn, il Hy Date: 06.02. 094 OTDR report Job info =D Tonite a eos peter Donny s aaa 7. KA Proper Menajen toners ame cacctemmstatnm oe bet ingen 14-58 | Link measurements or ae eS : rr ane jem : Reet, Ben oe mae OTDR trace : seul . « « = : ; 4 —__ 43 —_ 33 fe Events table “= | we Ceti tm] nt |e] ou a ta | | cath | Ut +] e000 | as ct cay ome Frbac(3347108m) ose | 2 2 | mere | Semen’ a7 He Testandcable setup eeeo ‘eso nce resetup zi foc See tare Min ne ro reese noe ams Source mona Suave arted (0 isi Software NIA Reflectance threshold -55.0 8 | — Sees Soomenmial : ee | JOR 1.488200 | | Res ‘e200 | OTDR report Job info. 1 Job 1D Wo 9105, Reason ] Contractor Operator A Donny § Customer PT. KA Properti Manajemen Operator 8 Test date (06/02/2024 (10:40:15 GMT+700) File After impact 14-5916.tre Link measurements ‘Span loss 6.174 48 "ANG. splice loss : Span length 33.4719 km, Max. splice loss Average loss (0.184 dBikm Span ORL. 31.12.68 OTDR trace a 0 3 spoof > 2 < « 1 10) ae a t 7% © ® % o mm Events table 1 No. lo. Event type, Loss Refi, Att Cumul, (ern) (a8) (8) | (@BKm) | (a8) 1 0.0000 | Launch Level - 487 0.000 Fiber Section (33.4719 km) 6.174 ote | 6.174 2 33.4719 | Reflecive Faut I 316 6.174 Test and cable setup Wavetenath | 1850 nm (SM-Sum) ‘Acq. time ‘Amin 37s Filename After impact 014-5916.tre Pulse wiath 275 ns Hardware MAX-730C-SM1-EA, Helix factor 0.00% Serial number ss11912 Splice loss threshold 0.100 48 Software Nia. Reflectance threshold 55.0 d8 Range 40,0000 km End-of-fber threshold 1.000 dB JOR 1.488200 RBS: -82.00 oc es Cable Name [Duct 48 Fiber Single Mode Fiber G.652.0 Wo. Number [WO 9105 Customer rroperti Mi DrumNo. | Diy - 59, Project Name KAI Clawi-Banjar —_ = Length No 199907 Test according to IEC 60794-1-€1 Test Apparatus Tensile tester, OTOR EXFO FT... 120, ‘Test Specification Tensile load = 0.290 Ton kg / 2900 N Time = 10 minutes: Length : + 40 m Relax time = 40 sec Additional oss after test < 0.05 dB/km Measuring wavelength: 1550 nm No. of measured fibers : 8 Fibers, 1 fiber each tube This cable has passed the test : yes /po~ Remarks: Reference value contains splicing value braking Wed = 65.5 6 ye OTDR report Job info Job ID wo 9105 Reason Contractor Operator A Donny $ Customer PT. KA Properti Manajemen Operator 8 Test date (06/02/2024 (9:59:28 GMT+7:00) File Before Tensile D14-5916.tre Link measurements Span toss 6.183 48 ‘Avg. spice loss. - Span length 33.4732 km Max. splice loss Average loss 0.185 dB/km ‘Span ORL 31.18 48 ~ OTDR trace a 404 Ee sooo” 2. « 20 18 10 so coool . o 5 & % 3 Es ro ~ Events table No, Los. Event type Loss Rett Alt Cumut kn) — (a8) (a8) | (Bm) | (8) 1 0.0000 | Launch Level --- | 458 0.0001 ber Section (99.4732 km) cies | ores | bes 2 33.4732 | Reflective Fault = | 328 6.183, Test and cable setup Wavelength 1850 nm (SM-9m) ‘Acq, time 3s Filename Before Tensile D14-5916 tre Pulse width 275 ns Hardware MAX-730C-SM1-EA Helix factor 0.00% Serial number 4511912 ‘Splice loss threshold: 0.100 dB Software NIA Reflectance threshold -§5.0.dB Range 40.0000 km_ End-offiber threshold 1,000 dB 1oR 1.468200, RBS -82.00 OTDR report - Job info Job 1D WO 8105 Reason Contractor ‘Operator A Donny § Customer PT. KA Properti Manajemen Operator B Test date 6/02/2024 (9:55:51 GMT+7:00) File ‘Alter Tensile 014-5916 tre Link measurements Span loss 6.181 48 ‘Avg. splve loss Span lenath 33.4719 km Max. spice loss ‘Average loss 0.185 dik Span ORL 30.96 4B OTOR trace « a sooo 18 . e % % 5 & & = ro Events table No Loe. Event type Loss | Rett an] Cuma | km) (8) (68) | (@Bkm) | (8) | 1 0.0000 | Launch Level oo 457 0.000 Fiber Section (93.4718 km) e181 018s | 6.181 2 334719 | Reflecive Faut = 292 e181 Test and cable setup Wavelenath 4650 nm (SM-Sum) ‘Acq, time 13min 188 Filename Alter Tensile D14-5916 tre Pulse wieth 275 ns Hardware MAX-730C-SMI-EA, Helix factor 0.00% Seti number asit912 Splice loss threshold = 0.10048 Software NA Reflectance threshold -55.0 48 Range 40,0000 km End-otfber threshold = 1.000 48 oR 4.486200, Res 82.00, Cable Name Duct 48 Fiber Single Mode Fiber G.662.D Wo. Number [wo 9105 Customer PT. KAProperti Manajemen : : Drum No [d= $416 Test according to HEC 60704-1.2.610 Test Apparatus orpr exro Fr....120. Test Speciation Bending rads 10 x Diamater Cable ‘Acceptance Criteria: No Kink on the jacket cable surface ‘Attenuation change 0.05 km Measuring wavelength: 1550 nm No. of measured fibers: 8 Fibers, 1 fiber each tube Test Result Fiber | Before Test (abikm) | Afler Test (dBvkm)] Change (aB/km) Colour at 1550. nm, at 1550 nm, at 1550 nm, This cable has passed the test : yes /no~ Remarks: Reference value contains splicing value QC-Inspector, Witnessed by, PT. CCS Indonesia Tok Crews ( Fal (eDIMES. a) ¢.CGy Sawery (Ateanere reastrg Date: 06.02. 2994 Length No A340 OTDR report Job info Job ID Wo 9105 Reason Contractor Operator A Donny § Customer PT. KA Properti Manajemen Operator 8 Test date (06/02/2024 (10:58:19 GMT+7:00) File Before kink D14-5916.re Link measurements Span loss 6.17 dB ‘Avg. splice loss Span length 33.4719 km ‘Max. splice loss Average loss 0.185 dk ‘Span ORL 31.120 OTDR trace «0 2 sooo > 2 ‘ « 15) 7 5 @ © % % o J Events table : = No. Loe. Event type Loss | Refi at. | Cumul (kr) (8) (8) | (Km) | (48) 1 0.0000 | Launch Level = 4857 0.000 Fiber Section (33.4719 km) e177 oss | 6.177 2 33.4719 | Reflective Fault 31.6 a7 Test and cable setup Wavelength 1860 nm (SM-Sum) ‘Acq. time 5s Filename Before kink D14-5916.tre Pulse with 275 ns Hardware MAX-730C-SMI-EA, Helix fact 0.00% Serial number 1511912 Splice loss threshold 0.100 d8 Software Nia Reflectance threshold -55.0 68 Range © 40,0000 km End.oliver threshold 1,000 8 oR’ 4.466200 RBS -82.00 OTDR report Job into ‘Job ID wo 8105, feason Contractor Speratr 4 Donny $ Customer PT. KA Properti Manajemen Operator| Test date (06/02/2024 (10:59:27 GMT+7:00) File After kink 014-916.tre Link measurements Span toss 6.175 a8 ‘Avg. splice loss zs Span length 33.4732 km Max. splice loss 2 Average loss 0.184 dBiken Span ORL 311468 OTDR trace «0 9s. saoof > 2s < 5 t ca 75 % & © ts km — Events table No | Loe Event type | toss | Rett at. | Cumul (xn) (@) | (8) | (eam) | (48) + 1 0.0000 | Launch Level --- | 457 | 000 Fiber Section (33.4732 km) 6175 | osee | 8.175 2 33.4732 | Reflective Faut o- | 319 6.175 Testand cable setup Wavelength 1550 nm (SM-9pm) ‘cg. time 1 min 26 s Filename After kink 014-5916 tre Pulse wrath 27508 Hardware MAX-7300-SMLEA Helix factor 0.00% Serial number isi1912 Splice loss threshold 0.10048 Software NIA Reflectance threshold -55.0 48 Range 40.0000 km End-offiber threshold 1.000 48 oR 4.468200 RBS, 82.00 : a? yg 2CSI Repeated Bending Test Cable Name Duct 48 Fiber Single Mode Fiber G.652.D Wo. Number [WO 9105 Customer PT. KA Properti Manajemen ] Drum No. | DIM- $416 Project Name (KAI Giawi-Banjar lengiNo [_ 145 HT" Test according to lec-60704-1-66 n Test Apparatus Ropeated bending tester, OTDR EXFO FTE... 70. Test Specification: Angle = + 90° Weight = > 5.5 kg Bending Radius = 15 x Cable Diameter Frequency = 30 cpm (60 cycles) Time ; 100 sec Time of relax : 10 sec ‘Additional loss after test < 0.05 dB/km Measuring wavelength: 1550 nm No. of measured fibers: 8 Fibers, 1 fiber each tube Tost Result Before Test (GBiKm) [After Test (dB/km)] Change (Bim) at 1550. nm, at 1550. nm at 1550. nm, This cable has passed the test : yes / 5 ‘Remarks: Reference value contains splicing value QC-Inspector, PT. CCS Indonesia Tok i feet 4y Date: Ob.0f. dod OTDR report Job info Job ID Wo 9105 Reason Contractor Operator A Donny § Customer PT. KA Proper Manajemen Operator B Test date 06/02/2024 (10:25:22 GMT+7:00) File Before r bending D14-5916.rc Link measurements Span loss 6.17408 'AVQ. splice loss Span length 33.4732 km Max. splice loss Average loss 0-184 dBikm Span ORL 31.0968 OTDRtrace ® 0 sooo > 2 1s 1008 ° E % % % 5 % & ca Events table No, | Loc. Event type Loss Refi, Att ‘Cumul. Len (eB) (8) | (@8km | 108) 1 0.0000 | Launch Level --- | 458 0.000 Fiber Section (33.4732 km) 6.174 ores | 6.174 2 33.4732 | Retlecive Fault 7 “310 e174 Test and cable setup Wavelenath 41550 nm (SM-9ym) ‘ca. time 5s Filename Before r bending 014-5916 tre Poise width 275s Hardware MAX-730C-SMI-EA, Helix factor 0.00% Serial number 4511912 Splice loss threshold 0.100 48 Software NIA Reflectance threshold -55.0 dB Range 40.0000 km End-ottiber threshold > 7.000 dB TOR 4.486200 RBS 62.00 anv OTDR report Job info Job ID WO 8105 Reason Contractor ‘Operator A Donny S Customer PT. KA Properti Manajemen Operator 8 Test date (06/02/2024 (10:26:28 GMT+7:00) File ‘After bending 014-5916.tre | Link measurements Span loss 6.171 68 ‘Avg, splice loss : Span length 33.4719 km Max. splice loss e Average loss 0.184 dBkm ‘Span ORL 31.09 48 OTOR trace = « 8 sooo > 250 “ < 15) 10 ct 5 0 5 % % w % cy Events table No. Loe. Event type Loss Ref at. | Cumul (em) (48) | (48) | (BKm) | (a) 1 0.0000 | Launch Level : 458 0.000 Fiber Section (33.4719 km) 6.171 o1e4 | B.7t 2 33.4719 | Reflective Fault = 31.0 6.171 Test and cable setup Wavelength 1850 nm (SM-Sum) ‘Acq. time 10 min 50s Filename After r bending D14-5916.te Pulse wiath 275 ns Hardware MAX-730C-SMI-EA, Helix factor 0.00% Serial number ss1t912 Splice loss threshold 0.100 48 Software NIA Reflectance threshold 85.0 48 Range 40,0000 km End-of-fber threshold > 1.000 d8 IOR 1.488200 RBs. -82.00 CCsI Cable Name [Duct 48 Fiber Single Mode Fiber G.652.D Wo. Number (WO9105 | Customer _|PT. KA Properti Manajemen Project Name [KAI Ciawi-Banjar _ Drum No. Diy~ 59/6 Lengtnno [79 7727 Test according to 1EC-60794-1-£7 Test Apparatus Torin tester, OTDR ExFO FT.122 Test Specification Length = 2 m Load = 250N (25 kg) Duration of Test = 30 twist (10 Minutes) ‘Angle = 2x + 180° (clockwise & counter clockwise) Time of relax = 10 seconds ‘Additional loss after test < 0.05 dB/km Measuring wavelength: 1550.nm No. of measured fibers: 8 Fibers, 1 fiber each tube ‘Test Result ‘After Test (dB/km)] Change (dB/km) at 1550 nm at 1550 nm This cable has passed the test : yes /95 Remarks: Reference value contains splicing value a -inspecter, Winessed by, Pr CCS imenasia Tok taut, 5 «Dimes ‘Been (Mrnerca, aaserve Date: 06.02. Zo d4 OTDR report Job info Job 10 wo 9108 Reason Contractor Operator A Donny § Cistomer PT. KA Propet Manalemen Operator 8 Test date 96/02/2024 (10:46:19 GMT 7.00) Fle Belore Tors D14 5916.6 Link measurements Span loss 6.175 48 "ava phe loss Span length 33.4719 km Max. epee los Average loss 0.184 dBm Span ORL 3hsee OTDR trace Py asco] woof 2 < “ ‘0 r a F 7% % % = & % cr = Events table No. Loe. Event ype toss | Ret | at | cumut | (km 8) | 8) _| aim | as) | 1 0.0000. | Launch Level -. | 487 2.000 | Fiber Section (33.4719 km) 6i75 ose | 8175 2 | ssari9_ | Reflectve Fact ve | ea 8175, Test and cable setup Wavelength 1860 nm (SM-G4m) ‘eg ome 53 Filename Belore Tosi 14-5916: Pale with Tne Herdware Macrae SMTA Hebe factor ooo% Serial number istiet2 Splice oss threshold 010048 Software NA Reflectance threshold “55.0 d8 Range 0.0000 km End-lber threshold 1-000 dB IR 4.488200 RBS “8200 aA\G OTDR report Job info ‘Job 10 wo 9105 Reason Contractor Operator A Donny § Customer PT. KA Properti Manajemen Operator 8 Test date. (06/02/2024 (10:47:25 GNT+7:00) File Aer Torsi D14-5916.re Link measurements ‘Span loss 6.175 0B "AVG. splice loss Span length 33.4719 km ‘Max. splice loss Average loss 0.184 dBm Span ORL. 31.11 dB OTDR trace « “0 2 sano 250 < « . 7% 5 % % % = im = Events table = No. Loc. Event type Loss: Ref Att Cuma (km) (a8) (48) | (dBm) | (08) 1 0.0000 | Launch Level : 457 9.000 | Fiber Section (33.4719 km) 175 oss | 6.175 2 | s3.4719 | Reflective Faut a 314 6.175 Testand cable setup Wavelength 1850 nm (SM-9um) ‘Acq. time. 40 mins Filename After Torsi D14-5916.tre Pulse with 275 ns Hardware MAX-7300-SM1-EA Helix factor 0.00% Serial number ss1t912 ‘Splice loss threshold 0.100 48 Software NIA. Reflectance threshold -85.0 dB Range 40,0000 km End-of-ber threshold: 1.000 48 JOR 4.488200 RBS, 62.00 CCSI Mee Owner Wo. Number , WO 9105 ‘Customer PKA PropertiManajemen Cable Name Duct 48 Fiter Single Mode Fiber 6.652. 7 Project Name KAL |Ciaw-Banjar a a 7 Test according to \EC-60794-1-2-F5B ‘Test Apparatus Water Penetration Tester Test Specification Length = 1m Pressure : 1 m height of water coloumin, No water detected at the end of the sample Testing Duration Sample No. | DrumNo. | Length No Start Finish coe ‘QC Inspector aula 1 Pps] 199907 Joserey| v0.00 | youn lever fare | Rese | Par This cable has passed the test 2 yes kno Remarks: fanjang tamludan : soem (osm) QC-Inspector, Witnessed by, “Dp wi) Tbk fan ( Dna Date: 60-07. Loay CCSI Design Test (oorerle eee eee Tete is eect ‘Wo. Number sWosts Customer PT.KAPropertiManajemen / - Drum No 2 DM $b Project Name: KAI Ciawi-Banjar Length No : M4aut Cable Name : Duct 48 Fiber Single Mode Fiber G652.D - OO Item to be verified [Specification / Requirement Result (Ok/Not OK) Fiber : a) [Fiber Type & Fiber Colour Each Tube _|Single mode G 652.0 & Fiber Colour : Bu, Og, Gn,Bn,Gy, Wh OK / Not Ok Buffer | _ ~ Buffer Tube Diameter & Colour 2.10 mm -/+ 0.10 mm Colour : BU,OG,GN,BN,GY, WH, RD,BK OK / Not Ok Existence of [Property — OK/NetOk (Cable Core (Core Element Central Member STW/PE, Buffer Tube, Swell Yam, Binding Yams and Water Blocking Tape | OK / Not-Ok Nr. Of Element & Sequence ___ |B Elements and Sequence : Bu,OG,GN,BN, GY, WH,RD.BK OK / Not Ok Jacket — Element [Cable Core, Aramide Yams, Ripcord and Alumunium-Tape —_ | OK/ Net oK [Outer Diameter 13.40 mm + 0.1 mm OK/NOFOK BAY mim [Material Name and Wall Thickness _|Black-Polyethylene, Thickness 2.30 mm (nominal) OK/NotOk 2-47 ttn [Cable weight |Approximately 151.32 gim (Tolerance 10 %) OkK/NotoR 145 im Printing Im] PT. KERETA API INDONESIA 2024 CCS INDONESIA KABEL OPTIK/SMD-LT 48/87 | OK / NotOk {mei} QC-Inspector, { ‘Witnessed by, PT. CCS Indonesia Tok on = cae GPA ie) & ys SN) ( Aueimorro, RRASEDXOY

You might also like