MICROPROCESSOR
PROTECTION RELAYS
THE “ M ” LINE

Digital relays for protection,


monitoring and control

SHORT FORM CATALOGUE


LINE

Digital relays
for protection,
monitoring
M Microelettrica Scientifica manufactures a
comprehensive line of protective relays for Electric
Power Production, Transmission & Distribution and for
the Industrial market.

The M relays offer that unique combination of performance,


functionality, innovation and reliability. A complete line of
microprocessor based relays for protection of high voltage and medium
voltage, transmission and distribution systems
including three phase overcurrent and earth fault, directional
overcurrent and earth fault,differential, over/under voltage, frequency,
and control powerfrequency/ load-shedding, motor protection, transformer
protection, capacitors protection, generator protection,
synchronising and load-sharing, synchro-check and D.C.
systems protection.
In addition to the flexibility of settings and
curves associated with modern protective
relays, all M relays also offer:

- Exceptionally simple and intuitive five button user


interface.

- Front panel or computer based programming and setting


changes for easy local or remote setting, with or without
a PC.

- Intense display visible in even brightly illuminated


environments.

- Auto-ranging power supplies and selectable 1-5 A inputs


take the guesswork out of stocking.

- Modbus protocol ensures communication compatibility


with RS485 or fiber optic interface.

- Compact, space saving design.

- Modular, draw-out design in a variety of case styles,


including 19” Rack panel.

- Conformance to all IEC255 and IEC1000


IEEEC37 Standards, CE Directive, UL-CSA approved.

- Programmable output relays, blocking inputs, and


blocking over-rides.

- Comprehensive self diagnostic - not just memory


checksums - periodically test the entire relay.

- Real time and recorded measurements.


C US LISTED - Event records and oscyllography.
19CN
IND.CONT.EQ. - Certified quality system ISO 9001 - ISO14001
M
LINE

Current Relays
A complete range of multifunction
three-phase + ground relays with
IM30-BY
46, 50/51, 50N/51N, 51BF, 68
• Three independent phase element
• Three Phase-Fault levels
• Two Negative Sequence levels
• Three Earth Fault levels
• Selectable double setting program
• Time tagged event recording
• Breaker Failure protection
cat. N38

• Blocking Output and Blocking Input for


pilot wire selectivity coordination
• Modbus Communication Protocol
• UL / CSA listed
IM30-SR
50/51,50N/51N,51BF,64S.E.F.,68,79
• Two Phase-Fault levels
• Two Earth-Fault levels
• Two Sensitive Earth Fault levels
• Selectable double setting program
• Four-shot programmable autoreclosing
cat. N28

• Blocking Output and Blocking Input for


pilot wire selectivity coordination
• Breaker Failure protection
• Modbus Communication Protocol
• UL / CSA listed
DM30-S
selectable and programmable time- cat. N27
current curves. All fitted with digital 50N/51N, 64S.E.F., 67, 68, 51BF
input/output for selectivity interlock • Two Directional / Non Directional Phase-
Versatile and suitable for any IM30-C cat. N06 fault levels
37,46N,50/51,50N/51N,51BF,68 • Two Earth-fault levels
application in HV, MV, LV.
• Two Sensitive Earth Fault level
• Two Overload levels • Blocking Output and Blocking Input for
• Two Unbalance levels pilot wire selectivity coordination
• Two Earth-Fault levels • Breaker Failure protection
• Undercurrent detection • Modbus Communication Protocol
• Dynamic Compensation of Capacitors • UL / CSA listed
I> I>> O> O>> Inherent unbalance
I>>> O>>> • Breaker Failure protection
PROG/ BLOCK BR. FUNC. • Time delayed capacitor reenergization DM33 cat. N37
I.R.F. INPUT FAIL. DISAB.
• Blocking Output and Blocking Input for pilot 27,50/51,50N/51N,51BF,59,59Uo,67,
wire selectivity coordination 67N,68,I2t
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
IA 500A • Modbus Communication Protocol
• UL / CSA listed • Three Overcurrent levels
• Three Earth-fault levels
MODE SELECT
+ • Zero sequence overvoltage level
• Two over / under voltage level
MULTIFUNCTION • Blocking Output and Blocking Input for
OVERCURRENT + _ pilot wire selectivity coordination
EARTH FAULT
RELAY TYPE PROG.
IM30-D cat. N05 • Breaker Failure protection
• Breaker Interruption Energy ΣI2t
IM30-AB 50/51,50N/51N,51BF,59Uo,67N,68,I2t
• Time tagged multiple event recording
ENTET/RESET • Three Phase-Fault levels • Modbus Communication Protocol
• Three Directional or not Directional Earth- • UL / CSA listed
Fault levels with Zero Sequence voltage
polarization
• Zero Sequence Overvoltage level Autoreclosing and
• Breaker interruption energy ΣI2t Synchrocheck Relays
• Inrush current bias
IM30-AB cat. N43 • Breaker Failure protection Suitable for any application in
• Blocking Output and Blocking Input for pilot HV, MV, LV systems.
50/51, 50N/51N, 51BF, 68 wire selectivity coordination
• Three Phase-Fault levels • Modbus Communication Protocol
• Three Earth-Fault levels • UL / CSA listed M-ARM513 cat. N32
• Selectable double setting program
• Time tagged event recording 79
• User programmable ouput relays • Single and Three-Phase reclosure
• Blocking Output and Blocking Input for • Up to Four-shot programmable
pilot wire selectivity coordination IM30-DR cat. N41 autoreclosing cycle
• Breaker Failure protection • Self powered digital inputs
• Modbus Communication Protocol 46,50/51,50N/51N,51BF,67N,68,79 • Serial communication with Modbus
• UL / CSA listed • Two Phase-Fault levels Protocol
• Two Earth-Fault levels • Event recording
• Zero Sequence Overvoltage level • Time tagging
IM30-AP cat. N40 • One Negative Sequence current level
• Four-shot programmable Autoreclosing RIA123 cat. R01
50/51, 50N/51N, 51BF, 68
• Reclosure sequence coordination
• Two Phase-Fault levels • Selectable double setting program 79,68
• Two Earth-Fault levels • Blocking Output and Blocking Input for pilot • Three shot programmable autoreclosing
• Selectable Time Current Curves wire selectivity coordination • 7 selectable reclosure programs
• Breaker Failure protection • Breaker Failure protection • Self powered digital inputs
• Blocking Output and Blocking Input for • IRIG-B Time Synchronization • Optional serial interface
pilot wire selectivity coordination • Modbus Communication Protocol • 3 electromechanical output relays
• Modbus Communication Protocol • UL / CSA listed • 3 optoisolated outputs for external counters
• UL / CSA listed • Local test facility

IM30-B00 cat. N49 SCM21 cat. N20


IM30-SA cat. N31
25, 27, 59, 81
50N/51N, 51BF, 68
46,50-51,50N-51N,51BF,64S.E.F.,68
• Dual input• Three Earth-Fault levels • Synchrocheck relay
• Selectable double setting program • Two Phase-fault levels • Voltage, frequency and fase displ. check
• Time tagged event recording • Two Earth-fault levels • Over / Under Voltage
• User programmable output relays • One Negative Sequence current level • Over / Under Frequency
• Blocking Output and Blocking Input for • One Sensitive Earth Fault level • Dead Line / Dead Bus programmable
pilot wire selectivity coordination • Blocking Output and Blocking Input for operation.
• Breaker Failure protection pilot wire selectivity coordination • C/B closing time control
• Modbus Communication Protocol • Breaker Failure protection • Event recording
• UL / CSA listed • Modbus Communication Protocol • Modbus Communication Protocol
• UL / CSA listed • UL / CSA listed
MM30-W cat. N30 MD32-T cat. N16
Motor Protection Relays 12/14,27/59,37,46,47,48,49,50/51, 87, 87N
51LR,55,64,66,68,81 • Three-phase percentage biased differential
Suitable for protection of • Thermal Image with prealarm level relay for two-winding transformers
medium / large induction motors. • Unbalance • Automatic correction of CTs’ mismatch and
• Earth Fault Transformer Vector Group
• Locked Rotor • Two differential current levels
• Over / Under Frequency • One restricted Earth Fault level
• Over / Under Voltage • 2nd and 5th harmonic adjust. restraint levels
• Starting Control • Programmable percentage bias curve
• No-Load Running • Oscillographic recording
MM30 cat. N02 • Control of n° of startings • Modbus Communication Protocol
• Overcurrent • UL / CSA listed
37,46,47,48,49,50/51,51LR,64,66,68
• Low Power Factor
• Thermal Image with prealarm level • Speed control MD33-T cat. N26
• Current Unbalance • RTD input
• Reduced Voltage Starting Control
50/51, 87
• Power and Power Factor measurements
• Earth Fault • Three-phase percentage biased differential
• Blocking Output
• Locked Rotor relay for three-winding transformers
• Modbus Communication Protocol
• Overcurrent • Two differential current levels
• UL / CSA listed
• No-Load Running • One overcurrent level
• Control of n° of startings • 2nd and 5th harmonic adjust. restraint levels
• Blocking Output • Programmable percentage bias curve
• Autosetting Transformer Protection Relays • Oscillographic recording
• Remote Trip Control • Modbus Communication Protocol
• Speed Control input • UL / CSA listed
Selection of different models to
• RTD input
meet the different requirements for
• Modbus Communication Protocol MTR33 cat. N39
• UL / CSA listed HV, MV, LV systems.
27, 37, 50/51, 59, 90
• Automatic voltage regualtion with
proportional control pulse
• Over / Under current lock-out and
IM30-T cat. N07
protection levels
46, 49, 50/51, 50N/51N, 51BF, 68, I2t • Over / Under voltage lock-out and
• Three Phase-Fault levels protection levels
• Three Earth-Fault levels • Line voltage drop compensation (optional)
• Two Thermal image elements with prealarm • Modbus Communication Protocol
• Two Negative Sequence current levels • UL / CSA listed
O> St No I< Is> • One I2t level
• Blocking Output and Blocking Input for
ROTOR I>> START
STALL INHIBIT pilot wire selectivity coordination
• Breaker Failure protection Generator Protection Relays
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
IA 500A • Modbus Communication Protocol
• UL / CSA listed For protection of MV & LV medium /
+
Large synchronous generator.
MODE SELECT

MULTIFUNCTION
MOTOR PROTECTION _ IM30-DT cat. N36
RELAY TYPE
MM30
PROG. 46, 49, 50/51, 51BF, 67N, 68, I2t
• Three-Phase Fault levels
I>->> I2> Ir O>
ENTET/RESET • Three Directional Earth-Fault levels
• Two Thermal image elements with prealarm PROG/ Z< BR. B.I./
• Two unbalance levels I.R.F. FAIL. F.D.

• One I2t level


• Blocking Output and Blocking Input for
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
IA 100A
pilot wire selectivity coordination
• Breaker Failure protection
• Modbus Communication Protocol MODE SELECT
+
• UL / CSA listed
GENERATOR
PROTECTION _
RELAY TYPE PROG.
IM30-G
MM30-D cat. N42
dA> dB> dC> dO> ENTET/RESET
37,46,47,48,49,50/51,51LR,66,67N,68
PROG/ 2H> 5H> BLOCK
• Thermal Image with prealarm level I.R.F. INPUT
• Directional Earth Fault
• Reduced Voltage Starting Control MICROELETTRICA SCIENTIFICA
MILANO ITALIA
dA50.00n
• Locked Rotor
• Overcurrent
• No-Load Running MODE SELECT
+ IM30-G cat. N10
• Current Unbalance
• Control of n° of startings
32, 40, 46, 50/51, 51BF, 64S, 68
MULTIFUNCTION
• Blocking Output TRANSFORMER _ • Two Overcurrent levels
• Autosetting
DIFFERENTIAL • Two Current Unbalance levels
RELAY TYPE
• Remote Trip Control MD32-T
PROG.
• Stator Earth Fault
• Speed Control input • Reverse Power
• RTD input
ENTET/RESET • Loss of field impedance element
• Modbus Communication Protocol • Blocking Output and Blocking Input for
• UL / CSA listed pilot wire selectivity coordination
• Breaker Failure protection
• Modbus Communication Protocol
• UL / CSA listed
MG30 cat. N29
Bus-Bar and Cable
21,24,27/59,32,37,40,46,49,50/27, Voltage and Frequency Relays
Differential Relays
50V/51V,51BF,60FL,64S,68,81
• Two voltage-controlled overcurrent levels Different technologies for different Three different models to meet any
• Two under-impedance elements applications requirement in HV, MV, LV systems
• Thermal image element with prealarm level
• Two unbalance elements
• Two over/under voltage elements
M-LIB3 cat. K04 UM30-A cat. N03
• Two over/under frequency elements 87B 24, 27d/59d, 47, 59, 59Uo, 78, 81
• Two over excitation levels • Modular expandable prewired multizone • Two V/Hz levels
• Two 95% Stator Earth Fault prot. elements system with check zone • Two Over / Under voltage elements
• One 100% Stator Earth Fault prot. element • Individual modules for: Bus Coupler / • Two Over / Under frequency elements
• One Reverse power protection element Sectionalizer Feeder - income with • Two Zero Sequence voltage levels with
• One inpedance elem.for Loss of Field prot. automatic replica of the position of the bus- Discrimination of faulty phase
• One under-power level bar switches and saturation detectors • Two positive / negative sequence voltage
• PTs' fuse failure protection • Oscillographic recording elements
• Inadvertent C/B closure protection • Zone percentage biased differential • Vector shift Detection on Generator
• Blocking Output and Blocking Input for protection Islanding
pilot wire selectivity coordination • No need for check-zone system CTs • Event recording
• Breaker Failure protection • Modbus protocol • Modbus Communication Protocol
• Modbus Communication Protocol • UL / CSA listed
• UL / CSA listed M-HIB3 cat. K05
87 UFD34 cat. N33
MD32-G cat. N15
• Two Differential levels 27, 59, 81, df/dt, dv/dt
50/51, 68, 87, 87N or 64S • Programmable percentage bias
• Through Overcurrent level • Three-phase Voltage, frequency relay for
• Phase Differential protection
load shedding
• Dual slope programmable percentage • Harmonic restraint
• Four Over / Under Frequency elements
bias curve • Breaker Failure protection
• Two Over / Under Voltage elements
• Earth Fault or Restricted Earth Fault • Oscillographic recordings
• Two df/dt elements
protection • Modbus Communication Protocol
• Harmonic Restraint • One dv/dt element
• UL / CSA listed
• Phase Overcurrent protection • Up to 16 user programmable output relays
• Breaker Failure protection • Event recording
• Modbus Communication Protocol MFP cat. N45 • Modbus Communication Protocol
• UL / CSA listed • UL / CSA listed
50/51, 87/85
• High Sensitivity
• High Speed
UB0/CR cat. J02/89 (Line “A”)
• High Stability with automatic Bias UFD14 cat. N25
64R • Adjustable stability coefficient 81, df/dt
• Rotor Earth Fault protection relay • Adjustable Compensation of Pilot circuit
impedance • Frequency relay for load shedding
• 1 Rotor Earth Fault adjustable level • Four Over / Under Frequency elements
• Continuous Monitoring of Pilot wires
impedance • Two df/dt levels
• Back-up Overcurrent element • One Undervoltage blocking level
Autosynchronizing & Load • Oscillographic Recording • Display of measured Voltage in primary
• Breaker Failure protection RMS volts
Sharing Control Relays • 5kV isolation level of the pilot • Up to 16 user programmable output relays
(15kV with additional transformer) • Event recording
For HV, MV, LV application • Up to 1000Ω pilots resistance • Modbus Communication Protocol
(up to 2500Ω with additional transformer) • UL / CSA listed

SPM21 cat. N21


25, 27, 59, 81, 90 dA> dB> dC> dsv dA> dB> dC> dsv dA> dB> dC> dsv

• Automatic Synchronization and PROG/ REMOTE CHANGE BLOCK


I.R.F. TRIP SET INPUT
PROG/ REMOTE CHANGE BLOCK
I.R.F. TRIP SET INPUT
PROG/ REMOTE CHANGE BLOCK
I.R.F. TRIP SET INPUT

Synchrochek MICROELETTRICA SCIENTIFICA


MILANO ITALIA
dA50.00n MICROELETTRICA SCIENTIFICA
MILANO ITALIA
dA50.00n MICROELETTRICA SCIENTIFICA
MILANO ITALIA
dA50.00n
• Fast proportional Voltage and Frequency
+ + +
regulation MODE SELECT MODE SELECT MODE SELECT

• Phase displacement checking with circuit LOW IMPEDANCE


BIASED DIFFERENTIAL _
LOW IMPEDANCE
BIASED DIFFERENTIAL _
LOW IMPEDANCE
BIASED DIFFERENTIAL _
RELAY TYPE RELAY TYPE RELAY TYPE
breaker’s closing time control M-LID3 PROG. M-LID3 PROG. M-LID3 PROG.

• Antimotoring ENTET/RESET ENTET/RESET ENTET/RESET

• Kicker pulse
• Event Recording
• Modbus Communication Protocol
• UL / CSA listed MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA

UNDER VOLTAGE
OVER VOLTAGE
ON

SCM21
O C O C O C O C O C O C

cat. N20
O C O C O C O C O C O C

25, 27, 59, 81


• Synchrocheck relay
• Voltage, frequency and phase displacement DISCREPANCY DISCREPANCY DISCREPANCY DISCREPANCY DISCREPANCY DISCREPANCY

check DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST

• Over / Under Voltage FEEDER INPUT MODULE


M-BF3
FEEDER INPUT MODULE
M-BF3
FEEDER INPUT MODULE
M-BF3
FEEDER INPUT MODULE
M-BF3
FEEDER INPUT MODULE
M-BF3
FEEDER INPUT MODULE
M-BF3
FEEDER INPUT MODULE
M-BF3
ALIM-LIB3

• Over / Under Frequency


• Dead Line / Dead Bus programmable
operation. MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA

• C/B closing time control


• Event recording O C O C O C O C

• Modbus Communication Protocol


• UL / CSA listed
O C O C O C O C

RRS cat. F04/98 (Line “A”)


DISCREPANCY DISCREPANCY DISCREPANCY DISCREPANCY

95 DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST DISCREPANCY TEST

• Generator Load Sharing control relay


FEEDER INPUT MODULE FEEDER INPUT MODULE FEEDER INPUT MODULE FEEDER INPUT MODULE
M-BF3 M-BF3 M-BF3 M-BF3

• Active or Reactive Power Control


Supervision and MX14-5 cat. X07 Rated Current:
PROGRAMMABLE I/O In = 1 or 5A; Ion = 1 or 5A
Control Relays

Electrical characteristics
• 14 Selfpowerd digital Inputs programmable Current Overload:
MU30 cat. Z01 as N/O or N/C 200A x 1sec;
• 5 Output programmable as Normally 10A continuous
MULTIFUNCTION THREE-PHASE Energize or Normaly Deenergize
MEASURING UNIT • Adjustable time delayed operation of output Burden on current inputs:
• Totally programmable AND/OR matrix phase: 0.01VA@1A,
• Programmable multiscale measuring range
• Local / Remote control 0.2VA@5A,
• Class 0.5 accuracy
• Serial communication with Modbus earth: 0.015VA@1A,
• 1 and 5A, 100-125V adjustable input Protocol
• Active Power proportional pulse output • Time tagged event recording
0.4VA@5A
• Active & Reactive Energy with • Local RS232 port Rated Voltage:
programmable integration time
• Max demand Recording
Un = 100-125Vac
• Oscillographic recording of input quantities MC-R cat. X05 Voltage overload:
(Version A) MULTIFUNCTION DATA RECORDING 2 Un continuous
or Load Active + Reactive Energy Profile
(Version LP) & COMMUNICATION MODULE Burden on voltage input:
• 16 Programmable thresholds • Communication Concentrator
0.04VA phase@ Un
• Five Programmable output relays • Memory expansion Averange power supply consumption:
• Event Counters • Serial communication via fiber optic or 8.5VA
• Modbus Communication Protocol RS485
• Time tagging
Output Relays:
• Local RS232 port
• UL / CSA listed Rating 5A,
Vn = 380 Vac
REX-8 cat. X06
A.C. resistive switching
MUCC cat. Z04 EXPANSION MODULE FOR 1100W, 380 Vac
DC MULTIFUNCTION M-LINE RELAYS Make=30A peak ≤ 0.5 sec
MEASUREMENT UNIT • Slave module serial controlled for
expansion of output relays
Break: 0.3A, 110Vdc.
• Oscillographic recording with time tagging L/R = 40msec
• 8 user programmable relays
on four measurements.
• Demand recording
• 1 diagnostic relay Operation ambient temperature:
• DIN Rail mounting (EN50022) -10°C / +55°C
• Real-time measurement of Voltage, Current,
• No operation time delay
Power Storage temperature:
• 8 programmable alarm levels. -25°C / +70°C
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
MICROELETTRICA SCIENTIFICA
MILANO ITALIA
Reference standards:
IEC60255, IEC61000, IEEE C37
R LOCK L Ax/I.R.F.
CE: EN50081-2, EN50082-2
f U P Q PRG
O1 Ax / I.R.F. EN50263, ENV50204
OFF
PROG/ P.F. Q BL. INPUT O2 UL and CSA approval file
R2
I.R.F. P DEM.REC.
O3 E202083
ON

MICROELETTRICA SCIENTIFICA Fn50.00Hz O4 S1 HOST Dielectric test voltage:


MILANO ITALIA
O5
MODE S2 SLAVE
IEC60255-5 2kV, 1 min.
I1
Impulse test voltage:
MODE SELECT
+ I2
IEC60255-5
5kV(mc),2kV(md)-1.2/50µs
I3

I4
MULTIFUNCTION
POWER / VOLTAGE _ I5
RS232 RS232
HF disturbance test (1 MHz burst test):
MANAGEMENT IEC60255-22-1 class 3
I6
RELAY TYPE PROG.
MW33 I7
COMMUNICATION MODULE Electrostatic discharge test:
RELAY MX7-5
ENTET/RESET
MC-R
IEC61000-4-2 level 4
Conducted disturbance immunity test
IEC61000-4-6 level 3
Radiated electromagnetic field
MT4 cat. Z02
immunity test:
4 RTD INPUTS for three wires IEC61000-4-3 level 3
probes type Pt100 Electrical fast transient/burst:
MW33 cat. N17
• Temperature monitoring and control unit IEC61000-4-4 level 4
27, 32, 55, 59, 81 • Four Pt100 inputs with dual level
• Two Frequency levels programmable alarm. Surge immunity test:
• Two Voltage levels • Four output relays. IEC61000-4-5 level 4
• 1 Power factor level • Two 3-Digit local displays Oscillatory waves (ring waves):
• 1 Q/P level • Plug-in terminals
IEC61000-4-12 level 4
• Two Active Power levels • Flush mounting
• Two Reactive Power levels Power frequency magnetic test:
MT8 cat. Z03 IEC61000-4-8 level 5
8 RTD INPUTS for three wires Pulse magnetic field:
MX7-5 cat. X04 probes type Pt100 IEC61000-4-9 level 5
PROGRAMMABLE I/O • Temperature monitoring and control unit Damped oscillatory magnetic field:
• Eight Pt100 inputs with dual level IEC61000-4-10 level 5
• 7 Selfpowerd digital Inputs programmable programmable alarm
as N/O or N/C Voltage interruptions:
• Three output relays
• 5 Output programmable as Normally IEC61000-4-11 200ms
• Two 3-Digit local displays
Energize or Normaly Deenergize
• Serial port RS485 HF induced voltage:
• Adjustable time delayed operation of output
• Modbus Communication Protocol IEC61000-4-1-A.2.6 level 4
• Totally programmable AND/OR matrix
• Plug-in terminals Resistance to vibrations and shocks:
• Local / Remote control
• Flush mounting
• Serial communication with Modbus IEC60255-21-1 and 21-2
Protocol
• Time tagged event recording
RCA cat. J07/93 (Line “A”)
• Local RS232 port • Trip circuit supervision relay.
Serial communication and Man Machine Interface
The M series is supported by an advanced communication
software with very comprehensive functionality and yet
remaining extraordinarily user friendly and versatile.

Serial Communication
and Man Machine Interface
Microelettrica Scientifica has developed and realized MSCom:
a communication program for Windows systems available in
two versions:

Professional (MSCom Pro) : is the full version program.


It allows to:
- Communicate with 250 Microelettrica Scientifica relays with
MODBUS RTU protocol and monitor up to 5 relays at the
same time.
- Save data coming from relays on disk
- Program or modify settings
- Manage the configurations of many relays at the same time
and store information on hard disk
- Print data tables or diagrams
- Periodically poll the relays and send measurement or event
data directly to the hard disk or a printer.
- Access the relays via modem
(PC-Modem.......Modem-relays).

Lite (MSCom Lite) : this version is freeware and support all the
microprocessor relays manufactured by Microelettrica Scientifica.
It can communicate only with one relay at a given time, can’t
communicate via modem, doesn’t have the Polling function
enabled.

MS-TD PRO 32 is the software used by Microelettrica


Scientifica to implement SCADA (Supervision Control and
Data Acquisition) systems based on data and measurement
coming from the Protection, Metering and Control devices
and designed according to customer requirements.
Founded in 1953, Microelettrica Scientifica has
developed a wide range of products, divided
into three main lines:
- Electronic Relays for Transmission,
Distribution and Machinery protec-
tion.
“A Line“ electronic analogic
“M Line” digital microprocessor
“DIN Line” digital compact.
- a.c./d.c. low and med-
ium voltage Contactors
and Disconnetting
Switches:
- “N” Series; Bar
Contactors ranging up
to 6000A 1000V
A.C./D.C.
- “LTH” Series: spe-
cially designed for
traction up to 1250A
1500V D.C.
- “LTHH” Series: spe-
cially designed for
traction up to 1750A
4000V D.C.
- “LTHH”:
Disconnecting
Switches elettromag-
netic, pneumatic or
motor driven ranging
up to 1750A 4000V
D.C.
- Resistors for any volt-
age and power rating,
neutral or forced air
cooled. MMICROPROCESSOR
PROTECTION RELAYS

For industrial application: THE “ M “ LINE


SEP 2002 - SF03 - Rev.0

load, regulation, earthing, Digital relays for protection,


monitoring and control
A
ANALOGIC
PROTECTION RELAYS
THE “ M “ LINE

filter. Electronic analogic

For railway application: brak-


protective relays

DIN MICROPROCESSOR
PROTECTION RELAYS
THE “ DIN “ LINE

ing, filter. ENTER SELECT RESET


PWR/
I.R.F.

TRIP

ON

OFF

N-M
DIN
RS232
A B + 0

RS485
PWR/
I.R.F.

RESET
TRIP

N-DIN
ENTER SELECT RESET M
PWR/
I.R.F.

TRIP

ON

OFF

N-DIN
RS232

Digital relays for low


voltage application

The performances and the characteristics reported in this catalogue are not binding and can modified at any moment without notice