You are on page 1of 7

lind a b | f o r a b e t t e r c l i ma te

LindabNR19
Wall diffuser

© 2020.06 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB.
Lindab's products, systems, product and product group designations are protected by intellectual property rights (IPR).
lind ab | for a bett er cl i m ate

Wall diffuser NR19


Dimensions
A + 25

B + 25
B
Ød1

40
100

20
Description

Ød2
NR19 is a rectangular diffuser with adjustable nozzles suit-
L2
L1 A
40
able for installation in a wall or skirting board. The diffus-
100
er is suitable for the horizontal supply of cooled air. The
nozzles at the front make it possible to vary the dispersal
pattern and thereby create different throws. The diffuser is
used with a WB type plenum box. The plenum boxes are

9
equipped with a damper and measuring device, enabling
individual adjustment.
0 - 50

• Individually adjustable nozzles


• Flexible dispersal pattern
• Regardless of straight ducting before the diffuser WB-1 Back connection
• Telescopic function in the plenum box
A
A xx B
B Size
Size Ød
Ød11 A
A B
B L1
L1 Weight
Weight
mm
mm mm
mm mm
mm mm
mm mm
mm kg
kg
300
300 -- 100
100 80
80 300
300 100
100 240
240 2.50
2,50
Maintenance 400
400 -- 150
150 100
100 400
400 150
150 240
240 3.50
3,50
500
500 -- 150
150 125
125 500
500 150
150 240
240 4.30
4,30
The front can be removed and the damper taken out for 500
500 -- 200
200 160
160 500
500 200
200 240
240 5.50
5,50
cleaning of internal parts or to gain access to the duct. The 500
500 -- 300
300 200
200 500
500 300
300 240
240 7.40
7,40
visible parts of the diffuser can be wiped with a damp cloth.

WB-2 Side connection

Order code A
A xx B
B Size
Size Ød
Ød22 A
A B
B L1
L1 Weight
Weight
mm
mm mm
mm mm
mm mm
mm mm
mm kg
kg
Product NR19 S AxB
300
300 -- 100
100 80
80 300
300 100
100 280
280 2.50
2,50
Type
400
400 -- 150
150 100
100 400
400 150
150 300
300 3.50
3,50
NR19
500
500 -- 150
150 125
125 500
500 150
150 325
325 4.30
4,30
Functional use
500
500 -- 200
200 160
160 500
500 200
200 360
360 5.50
5,50
S ( Supply air )
500
500 -- 300
300 200
200 500
500 300
300 400
400 7.40
7,40
Size (A x B)
300x100 - 500x300

Product WB a AxB
Materials and finish
Type
WB
Diffuser: Galvanised steel
Connection
Nozzles: ABS plastic
1 = Back
Standard finish: Powder-coated
2 = Side Standard colour: RAL 9003 or 9010 white,
Size (A x B) gloss 30
300x100 - 500x300
The diffuser is available in other colours. Please contact
Example: NR19-S-500x200 + WB-2-500x200 Lindab’s sales department for further information.

2 Lindab reserves the right to make changes without prior notice


2020-06-18
lind a b | f o r a b e t t e r c l i ma te

Wall diffuser NR19


Technical data Sound attenuation

Capacity The diffuser’s sound attenuation function from duct to room,


including end reflection - see table below.
Volume flow qv [l/s] and [m3/h], total pressure loss Δpt [Pa],
throw l0.2 and sound level LWA [dB(A)] can be seen in the
diagrams.
WB-1 Back connection

Frequency-related sound effect level AxB Centre frequency Hz


mm 63 125 250 500 1K 2K 4K 8K
The sound effect level in the frequency band is defined as 300 - 100 27 19 14 7 8 9 9 14
LWOK = LWA+ Kok. Kok values are specified in charts beneath the 400 - 150 22 20 7 6 9 8 9 12
diagrams on the following pages. 500 - 150 20 18 7 9 7 7 8 12
500 - 200 18 15 4 9 7 7 8 12
500 - 300 15 12 2 10 6 7 7 9

Quick selection
WB-2 Side connection
WB-1 Back connection
AxB Centre frequency Hz
Minimum pt = 50 Pa pt = 50 Pa mm 63 125 250 500 1K 2K 4K 8K
AxB Pi>5 Pa LWA=30 dB(A) LWA=35 dB(A) 300 - 100 26 17 11 8 9 11 9 12
mm l/s m3/h l/s m3/h l/s m3/h 400 - 150 22 17 5 8 6 8 9 12
300 - 100 12 42 23 83 28 101 500 - 150 18 17 5 8 7 6 8 11
400 - 150 23 81 28 101 42 151 500 - 200 19 13 3 7 7 7 9 10
500 - 150 29 103 38 137 60 216 500 - 300 15 10 3 2 8 7 8 10
500 - 200 36 130 55 198 78 281
500 - 300 51 184 - - 103 371

WB-2 Side connection


WB back and side connection
Minimum pt = 50 Pa pt = 50 Pa
AxB Pi>5 Pa LWA=30 dB(A) LWA=35 dB(A)
mm l/s m3/h l/s m3/h l/s m3/h
300 - 100 12 42 20 72 25 90
400 - 150 23 81 36 130 44 158
500 - 150 29 103 - - 55 198
500 - 200 36 130 - - 74 266
500 - 300 51 184 - - - -

Throw l0.2

The throw is specified at a terminal velocity of 0.2 m/s.

400x150 500x200
l0.2 [m] NR19 300x100 500x150 500x300
10

8
7
6
5

1
l0.2 [ m ]
Balancing
qV [l/s]
10 15 20 30 40 50 60 70 80 100 150 200
qV [m3/h]
40 50 60 70 80 100 150 200 300 400 500 700 Balancing data is contained in a separate brochure.

Lindab reserves the right to make changes without prior notice 3


2020-06-18
lind ab | for a bett er cl i m ate

Wall diffuser NR19


Technical data WB Damper

Air jet dispersal


lb = Distance from the diffuser to the point where there is
maximum dispersal.
bv = Depth of the air jet on a vertical plane.
bh = Width of the air jet on a horizontal plane.

bv

l0,2
bh

l0,2

Normal nozzle setting


l0.2: Diagram value
bv: 0.05 × l0.2
bh: 0.7 × l0.2

Short throw
l0.2: 0.7 × Diagram value
bv: 0.05 × l0.2
bh: 0.85 × l0.2

Long throw
l0.2: 1.4 × Diagram value
bv: 0.05 × l0.2
bh: 0.5 × l0.2

4 Lindab reserves the right to make changes without prior notice


2020-06-18
lind a b | f o r a b e t t e r c l i ma te

Wall diffuser NR19


WB 1 - back connection WB 2 - side connection

∆p t [Pa ] NR-19-S-300-100+WB-1-300x100 ∆p t [ Pa ] NR-19-S-300x100+WB-2-300x100


250 250
200 200
150 50 150
50
45
100 100 45
40
70 70
40
35
50 50
30 35

30 25 30 30

20 20 20 25
15 15
LWA dB(A) 20 LWA d B( A )
10 10
q V [l/ s] q V [ l/ s]
10 15 20 30 40 50 60 70 10 15 20 30 40 50 60 70
q V [m 3/h] q V [ m 3/ h ]
30 40 50 60 70 80 100 150 200 30 40 50 60 70 80 100 150 200

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 13 -3 1 -1 -4 -14 -19 -26 Kok 3 0 4 -1 -6 -16 -21 -28

∆p t [Pa ] NR-19-S-400x150+WB-1-400x150 ∆p t [Pa ] NR-19-S-400x150+WB-2-400x150


250 250
200 200
150 150
50
50
100 45 100
45
70 40 70 40
50 35 50 35

30
30
30 30
25
25
20 20 20
15 20 15
LWA dB(A) LWA dB(A)
10 10
q V [l/ s] q V [l/ s]
10 15 20 30 40 50 60 70 80 90 10 15 20 30 40 50 60 70 80 90
q V [m 3/h] q V [m 3/h]
40 50 60 70 80 100 150 200 300 40 50 60 70 80 100 150 200 300

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 2 0 1 0 -6 -14 -20 -27 Kok 4 2 2 -2 -5 -12 -20 -28

∆p t [Pa ] NR-19-S-500x150+WB-1-500x150 ∆p t [Pa ] NR-19-S-500x150+WB-2-500x150


250 250
200 200
150 150
50
100 100 50
45
70 70 45
40
50 50 40
35
35
30
30 30
30
25
20 20 25
20
15 15
20
LWA dB(A) LWA dB(A)
10 10
q V [l/ s] q V [l/ s]
15 20 30 40 50 60 70 80 90 15 20 30 40 50 60 70 80 90
q V [m 3/h] q V [m 3/h]
50 60 70 80 100 150 200 300 400 50 60 70 80 100 150 200 300 400

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 5 -1 2 0 -7 -14 -21 -29 Kok 5 1 0 -2 -4 -13 -22 -33

Lindab reserves the right to make changes without prior notice 5


2020-06-18
lind ab | for a bett er cl i m ate

Wall diffuser NR19


WB 1 - back connection WB 2 - side connection

∆p t [Pa ] NR-19-S-500x200+WB-1-500x200 ∆p t [Pa ] NR-19-S-500x200+WB-2-500x200


250 250
200 200
150 150

100 50 100
50
70 45 70
45
50 40 50
40
35
30 30 35
30
20 20 30
25
15 15 25
20
LWA dB(A) LWA dB(A)
10 10 20
q V [l/ s] q V [l/ s]
30 40 50 60 70 80 90 100 150 200 30 40 50 60 70 80 90 100 150 200
q V [m 3/h] q V [m 3/h]
100 150 200 300 400 500 700 100 150 200 300 400 500 700

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 4 -1 1 0 -6 -14 -21 -29 Kok 1 2 3 -1 -6 -16 -23 -31

∆p t [Pa ] NR-19-S-500x300+WB-1-500x300 ∆p t [Pa ] NR-19-S-500x300+WB-2-500x300


250 250
200 200

150 150

100 100
50 50
70 70
45 45
50 50
40 40
30 35 30 35

30 20 30
20
15 25 15 25
LWA dB(A) 20 LWA dB(A)
20
10 10
q V [l/ s] q V [l/ s]
30 40 50 60 70 80 90 100 150 200 30 40 50 60 70 80 90 100 150 200
q V [m 3/h] q V [m 3/h]
150 200 300 400 500 700 150 200 300 400 500 700

Hz 63 125 250 500 1K 2K 4K 8K Hz 63 125 250 500 1K 2K 4K 8K


Kok 7 2 2 0 -7 -14 -21 -31 Kok 1 3 0 -1 -4 -16 -26 -37

6 Lindab reserves the right to make changes without prior notice


2020-06-18
Most of us spend the majority of our time indoors. In-
door climate is crucial to how we feel, how productive
we are and if we stay healthy.

We at Lindab have therefore made it our most important


objective to contribute to an indoor climate that improves
people’s lives. We do this by developing energy-efficient
ventilation solutions and durable building products. We
also aim to contribute to a better climate for our planet
by working in a way that is sustainable for both people
and the environment.
Lindab | For a better climate

www.lindab.com For a better climate

You might also like