Q bank HVACR for IA2

(paper pattern: Q1 theory, Q2 and Q3 numericals)

1. What is effective temperature? Explain various factors affecting effective temperature?

2. Explain working of ammonia water vapor absorption system with neat sketch

3. Explain specific humidity, relative humidity, degree of saturation, dew point temperature, humid
air enthalpy, vapor density, equation to determine partial pressure of water vapor in air

4. Explain RSHF, GSHF, ERSHF, bypass factor

5. Explain the components of cooling load (heat sources)

6. Explain types of pressure losses in duct

7. Explain the three fan laws

8. Classify ducts, compressors, condensers, expansion devices, evaporators

9. Explain ice plant

10. Explain thermostatic expansion valve with a sketch.

11. Explain capillary tube

12. In an ideal vapour absorption system evaporator temperature is 250 K, condenser temperature is
300 K and generator temperature is 370K. Another vapour absorption system has same evaporator
temperature and condenser temperature but generator temperature is 420K Determine the COP
and mention which one will you select

13. Two coils with ADP 10 o C. Both have inlet temperature 37 o C. Outlet temperature of coil-1 is 14 o
C. Outlet temperature of coil-2 is 12 o C. Based on calculation of bypass factor select the one that is
better in performance.

14. An AHU of AC system supplies 1 m3/s air which comprises by weight 20% fresh air at
40oC DBT and 27oC WBT and 80% recirculate air at 25oC DBT and 50% RH. Air leaves
cooling coil at 13oC saturated state. Find total room heat to select the room for which this AC
system will be suitable.

15. Two air streams are mixed to get a resultant stream of DBT 10oC. The stream at 2oC DBT
80% RH flows at the rate of 5m3/s. The other stream to be mixed with it is having 30oC DBT
27oC WBT. Determine the appropriate flow rate for second stream. If this other stream
changes its state to 35oC DBT 30oC WBT, what flow rate will be required

16. An AC system is to be designed. RSH is 31.44 kW RLH is 8.3 kW. 25% fresh air and
75% recirculated air by mass is mixed and passed through conditioner coil of bypass factor
0.2. Find the amount of air required and ADP of coil. Room design condition 24oC, 50% RH
and outside design condition 40oC DBT, 29oC WBT.
17. An AC system is to be designed. RSH is 52.11 kW and RLH is 20.4 kW. Mixing of
recirculated air is done after cooling coil. 60% of total air is recirculated. Coil ADP is 10 oC.
Find the refrigeration load and supply condition. Assume outdoor condition 38oC DBT, 28oC
WBT. Indoor condition 24oC DBT, 60% RH.

18. A sample of moist air has 32oC DBT, 27oC WBT if barometric pressure is 750 mm of Hg. Determine
the following (without using psychrometric chart) specific humidity, relative humidity, enthalpy,
specific volume, DPT.