BWMS(PURIMAR) A/S TROUBLESHOOTING DOCUMENT
[Rectifier] – [Troubleshooting] – [BAM-RT-09]
PIC #1.
[Cause / Action]
2.2.1 (In case of new type) Fuse out due to OVER LOAD
(In case of old version)1. Fuse out due to OVERLOAD
(In case of old version)2. Input Line Fault – Cable connection or Protection
Board fault
REC-100B
1-2) Or, click on [Start] button of the rectifier on the HMI screen.
1-3) If the SHDN occurs again after the fuse was replaced, contact S&SYS.
3/4 Version. 0
BWMS(PURIMAR) A/S TROUBLESHOOTING DOCUMENT
[Rectifier] – [Troubleshooting] – [BAM-RT-09]
2-4) If the cable connection is normal, the protection board might be problematic. Therefore,
please check and replace the protection board.
2-5) If the rectifier is still abnormal even after the p.board was replaced, please contact
S&SYS.