PLANO LLAVE

POLIGONO TERRACERIA (UTM-WGS84 - ZONA 17N)

N PUNTOS COORD. (Y) NORTE COORD. (X) ESTE

PC-1 992894.60 363720.10

W E PC-2
PC-2 992902.10 363712.02

PC-3 992894.77 363705.22

E 363400

E 363450

E 363500

E 363550

E 363600

E 363650

E 363750

E 363800
S PC-4 992877.31 363687.28

5
14
N 992900 N 992900 N 992900 N 992900 N 992900 N 992900 N 992900 N 992900

0
00
PC-3 PC-5 992864.85 363675.71

0+
PC-6 992832.93 363661.34

PC-7 992832.18 363661.26

0
PC-1

02

105
140

0+
PC-8 992822.65 363659.11
PC-4

115
PC-9 992768.68 363640.27

110
120
0
PC-10 992764.23 363624.50

04
0+

100
PC-51

:1
PC-11 992783.31 363599.72

:1
5V

.5 V
PC-50
PC-5

.
H: 1
PC-12 992780.29 363576.79
E 363400

E 363450

E 363500

E 363550

E 363600

E 363800
H: 1
145

:1

0
06
.5 V
PC-13 992726.08 363535.34

0+
H: 1
N 992850 N 992850 N 992850 N 992850 N 992850 N 992850
SONDEO 12
N=992854.370 PC-14 992714.79 363522.58
E=363641.980 SONDEO 13
Z=141.010 PC-6 N=992833.010 PC-15 992672.98 363451.21
SIMBOLOGÍA

1 50
E=363717.290

0+080
Z=123.787 PC-16 992661.35 363440.36
PC-49

V: 1
PC-48 PC-17 992660.39 363439.88

H: 1.5
PC-7
SONDEO 14 PC-18 992631.23 363412.65 CORTE
N=992826.030
PC-8
E=363696.230 PC-19 992623.05 363399.81

00
Z=129.911

0+1
TANQUE DE
ALMACENAMIENTO PC-20 992616.33 363398.20 RELLENO

:1
E 363400

E 363450

E 363500

E 363800
PC-21 992577.05 363421.22

.5 V
SONDEO 15

V: 1
H: 1
N=992806.960 PC-22 992655.83 363553.70 PUNTOS DEL POLÍGONO DE TERRACERÍA

.5
N 992800 N 992800 N 992800 E=363681.290 N 992800

H: 1

20
Z=134.401

0+1
SONDEO 16 PC-23 992652.09 363566.19
N=992786.496
E=363526.917 PC-45 PC-46 UBICACIÓN DE SONDEOS
PC-24 992650.92 363570.13
Z=158.091

PC-47 PC-25 992648.85 363577.95


POLÍGONO TERRACERÍA

40
PC-26 992648.46 363579.44

0+1
1
V:
PC-11

V:
PC-12 125
.5

5
1 PC-44 PC-27 992648.06 363581.98 LIMITE DE MOVIMIENTO DE TIERRA

1.
H:

1
H:

V:
5
PC-28 992648.64 363584.59

1.

0
PC-9

12
H:
LIMITE DEL POLÍGONO DE LA COMARCA

1
V:
PC-29 992649.93 363586.82

60
1.
PC-43
PC-10

1
H:

0+1
E 363450

E 363750

E 363800
V:

5
PC-30 992650.60 363588.25

10
5

0
1.

11
H:

0
10
N 992750 N 992750 N 992750 PC-31 992652.67 363593.10

95
PC-42
PC-32 992653.87 363595.87
FILTROS

:1
18
O
PLANOS DE REFERENCIA

V

0+
PC-33 992655.21 363598.57

H: 2
SONDEO 18
N=992739.770 DE
V :1
E=363607.260 R DE PC-34 992659.82 363607.80
1.5 PC-41
H: BO
155

Z=134.599
PC-35 992664.23 363614.44

0
20
0+
1
PC-36 992665.29 363620.09

V:
1 PC-13
V:

5
1.5
160

1.
SEDIMENTADORES
H:

H:
PC-37 992667.42 363624.32
: 1
1. 5V SONDEO 19 PC-38 992667.85 363626.39

0
H: PC-14

22
N=992713.219

0+

E 363650

E 363800
1 E=363572.572
V: Z=141.685
PC-39 992691.03 363617.34
1.5 00 ENTREGA INICIAL 02-08-22 H.B. J.R. O.C.
N 992700 H: N 992700 N 992700 N 992700 N 992700
SONDEO 20 PC-40 992700.81 363614.78
V :1 PC-40 REV DESCRIPCIÓN FECHA DIBUJADO COMPROBADO APROBADO
N=992700.574
1.5 FLOCULADORES 0
H:
24
E=363400.585 PC-41 992732.36 363639.07
0+

Z=162.838 REVISIONES
PC-39 PC-42 992747.38 363647.16
1

125
V: 60
1.5 2 PC-43 992761.18 363651.98
H: 0+
SONDEO 21 PC-44 992773.96 363660.67
N=992678.861 PC-38
E=363498.793 280
0+ PC-45 992791.96 363666.97
Z=141.024 ESPESADOR DE
PC-15
LODOS
EDIFICIO DE PC-37 PC-46 992796.20 363682.33
0 CONTRATO : FECHA :
QUÍMICOS 0
0+3 PC-36
SONDEO 22 PC-47 992784.37 363697.81
PC-35

E 363650

E 363750

E 363800
N=992661.843
PC-16 E=363527.079 PC-33 PC-34 FIRMA Y SELLO INGENIERO IDÓNEO
Z=132.386
PC-48 992830.70 363733.37
EDIFICIO DE PC-32
N 992650 PC-17 N 992650 N 992650 N 992650
ADMINISTRACIÓN 0 PC-49 992834.88 363732.85
0 PC-31 12
32 PC-22
0+ PC-30
SONDEO 23 0 PC-23 PC-50 992858.60 363701.93
34 PC-29
N=992644.268 0+ 11
5
PC-24 PC-28
E=363472.078 PC-51 992869.64 363698.48
Z=137.413 PC-25
PC-27
0
36 1 PC-26
0+
2 V:
E RÍO
PC-18 H: ED FIRMA DE APROBACIÓN - DIRECTOR NACIONAL DE INGENIERÍA
R D
0 BO
TALLER Y 38 NOTAS:
0+ : 1 115
PC-19 ALMACÉN 2V 1. LAS MEDIDAS ESTÁN EN METROS SALVO SE INDIQUE LO CONTRARIO.
H:
PC-20 2. ANTES DE EJECUTAR LOS TRABAJOS DE ESTABILIZACIÓN SE DEBERÁN
105
155

SONDEO 24 0
40
0+
1

N=992613.944 REALIZAR ESTUDIOS MÁS COMPLETOS DE CARACTERIZACIÓN DEL


V:

E 363600

E 363650

E 363700

E 363750

E 363800
E=363429.968
.5

SUELO, DETECCIÓN DE NIVEL FREÁTICO Y ENSAYOS DE LABORATORIO


:1

Z=142.288
H

42
0 MÁS ESPECÍFICOS COMO HUMEDAD, GRAVEDAD ESPECÍFICA Y CORTE
N 992600 0+ N 992600 N 992600 N 992600 N 992600 N 992600 UBICACIÓN:
DIRECTO PARA CONOCER LAS PROPIEDADES DEL MISMO. PANAMÁ, PROVINCIA DE BOCAS DEL TORO
IA
LOR 3. LAS POSICIONES DE LOS SONDEOS CORRESPONDEN AL DISEÑO DISTRITO DE CHIRIQUÍ GRANDE
44
0
LA G PRELIMINAR Y DEBERÁN SER VERIFICADOS PREVIO A EJECUCIÓN DEL
RÍO
0+ PROYECTO :
ESTUDIO DE SUELO.
45
4
4. SONDEOS HASTA PERFORAR MÍNIMO 1.50 M EN LA ROCA, REALIZAR:
ESTUDIO, DISEÑO, CONSTRUCCIÓN,
0+
13
5 - SPT OPERACIÓN Y MANTENIMIENTO
110

13
0 - HUMEDAD DE LA PLANTA POTABILIZADORA
R ÍO
12
5 DE - DETECCIÓN DE NIVEL FREÁTICO
PC-21
BO RDE DE CHIRIQUÍ GRANDE
- SE RECOMIENDA REALIZAR ENSAYO DE PENETRÓMETRO DE BOLSILLO O
155

ENSAYO DE VELETA EN LOS SUELOS COHESIVOS. Y REDES DE ABASTECIMIENTO,


- EN LOS SONDEOS 12,13,16,19,20,23 Y 24 REALIZAR ENSAYOS DE CORTE PROVINCIA DE BOCAS DEL TORO
160

DIRECTO
15 TÍTULO DE PLANO :
E 363400

E 363450

E 363500

E 363550

E 363600

E 363650

E 363700

E 363750

E 363800
1
- EN LOS SONDEOS 20 Y 21 REALIZAR EXTRACCIÓN DE TESTIGOS DE ROCA,
PLANTA DE TRATAMIENTO DE AGUA POTABLE
REALIZAR ENSAYO DE COMPRESIÓN SIMPLE A LA ROCA Y DETERMINAR LOS
N 992550 N 992550 N 992550 N 992550 N 992550 N 992550 N 992550 N 992550 N 992550 N 992550
TERRACERÍA
CRITERIOS DE ÍNDICE DE FUERZA GEOLÓGICA (GSI), CONSTANTE DE FUERZA
DE MATERIAL EN ROCA PARA LA PEOR CONDICIÓN(MI), COEFICIENTE DE DISEÑO PRELIMINAR

PLANTA GENERAL DE UBICACIÓN DE SONDEOS - TERRACERÍA PLANTA DE TRATAMIENTO DE AGUA POTABLE MASA DE ROCA DAÑADO (D). PLANTA GENERAL DE UBICACIÓN DE SONDEOS
ESC.: 1:750 Escala:
0 7.5 15 22.5 30 37.5 m.
1:750 1:750

CÓDIGO DE PLANO : HOJA: 01

PLCHG-DEPL-A3-GTNB-001 DE: 01

ARCH D ( 36 x 24 )