Professional Documents
Culture Documents
Ylp 1 100 30 30 HC
Ylp 1 100 30 30 HC
SPECIFICATION Revision: 02
MODEL YLP-
YLP-1-100-
100-30-30-HC
Page: 1 of 5
1. Optical characteristics
N Characteristic Test condition Symbol Min Typ Max Unit
1 Mode of operation Pulsed
2 Polarization Random
3 Nominal average output power Pnom 29 30 31 W
4 Central emission wavelength Pout = Pnom λ 1055 1064 1070 nm
5 Output power adjustment range 10 100 %
6 Emission bandwidth FWHM ∆λ 5 10 nm
MO ON
Average power at
7 BS OFF or 2 mW
Booster OFF
Emerg. STOP
Average power at MO ON
8 Booster ON and BS ON 150 mW
zero Power settings D0…D7 = 00h
Long-term average power Pout = Pnom
9 2 5 %
instability over 5 hrs
FWHM
10 Pulse duration Pout = Pnom ∆τ 90 100 120 ns
PRR = 30 kHz
Pout = Pnom
11 Laser switching ON time 140 220 µs
0 → 90%
12 Laser switching OFF time 3 µs
13 Pulse repetition rate PRR 30 200 kHz
Pout = Pnom
14 Pulse energy 1 mJ
PRR = 30 kHz
15 Red guide laser power (optional) λ=660nm 0.2 0.5 1 mW
2. Optical output
output (with built-
built-in optical isolator)
N Characteristic Test condition Sym
Symbol Min Typ Max Unit
16 Protection cable metal shielded/ PVC coated
17 Cable diameter 6 7 mm
18 Beam quality M2 1.5 2.0
19 Output fiber cable length 3.0 m
20 Output beam diameter 1/e2 level 6 7.5 9 mm
21 Output beam ellipticity 10 20 %
22 Output beam offset 1 1.5 mm
23 Output beam misalignment 8 12 mrad
24 Output beam divergence adjustment minimum of divergence
3. Control interface
interface,
nterface, type B1
B1
4. Electrical characteristics
characteristics
N Characteristic
Characteristic Test condition Min Typ Max Unit
25 Laser module supply voltage 23 24 25 VDC
26 Current consumption Pout = Pnom 9 A
5. General characteristics
characteristics
N Characteristic Min Typ Max Unit
Module operating temperature range
27 ● 50% emission time 0 +42 °C
● 100% emission time +36
28 Storage temperature -10 +60 °C
29 Cooling method 3 built-in fans
Warm-up time:
30 ● to start of operation 0.1 min
● to full stabilization 10
31 Humidity (non-condensed) 10 95 %
32 Laser module dimensions 215x95x286 mm
6. Delivery options
options
● Red guide laser
● Power supply 100/240 AC
● Alteration of the output beam diameter
● Alteration of the output fiber length
● USB Remote Control, laboratory grade (including PC software)
7. Certification
Test data shipped with each laser:
● Nominal output average power, W
● Pulse repetition rate, kHz
● Operating wavelength, nm
● Pulse duration (at 30 kHz, nominal output power), ns
● Output power instability, %
● Beam diameter (1/e2 level), mm
● Laser ON/OFF delays (nominal output power), µs
● Nominal current consumption, A
3
1