You are on page 1of 37
me roo III SECTIONAL VALVE Applications ‘The vaive is available with manual and hydraulic remote controls. ‘Working sections have auxiliary valves and a broad range of interchangeable spools. Suitable for applications including Wheel loaders, Truck cranes, Sea platform cranes, Drilling machines, Presses. SECTIONAL VALVE J D25 QUICK REFERENCE GUIDE GENERAL SPECIFICATION D9 DSM DVSIO D4 D6 Dis Di2 DVS20 D20 D25 p40 Working sections number rR or 2 ot Fe rR ar |B) 0 cacurr Paraie : s . © © © = © & . Series :. » . » » . ‘Tandem a. =. 2 . Parallel creut stroke (mm) 6 5 6 6 7 7 98 95 95 32 15 Series circuit stroke (mm) 6 5 6 6 5 7 65 65 | 85 Flat spool extra stoke (mm) 5 5 5 55 6 7 7 7 7 (95 10 ‘Spools pitch (mmm) Bt 383540 GSS wD RATED FLOW Max recommended flow rate (Vmin) 35 55 45 80100150 180250250 | 380") 700 Max recommended flow rate (GPM) so 15 12 oa? 100385 [RATED PRESSURE Max working pressure (bar) 350 350 350 350 350-350-350 250350 BBOl) 350 Max working pressure (PSI) sooo S000 5000 som saeo 5000 5000 4000 S000 $000 $000, OPTION CHART 9 DSM pvsI0 D4 D6 Dis B12 DVS20 D20 025 p40 Direct acting pressure rele valve oe ee Pilot operated pressure reli valve . = Care « . 2 stage pilot operated relief valve : afs ff - - a. Externally pllted valve 7 sw © \e ws . a. ‘Solenoid dump valve (12 Vee) ey Solenoid dump velve (26 Vde) . -« » be «#6 « Main antcavitation check valve : oe e « e+ me ‘lamping valve 1 2 #8 ‘SPOOL ACTUATION Manual control 7 a e-)e eo ew ew eh lh without lever o «lw eo o « « «Mme 90° joystick control Hydraulle control “0 «6 e« .o « « © «Mm Direct electric control (12-24 Vide) . . ‘SPOOL RETURN ACTION Spring return : . = © 2 © se os © . Detent in Ain 8-in AB . Detent in 4 position | . Arrangement for dual contr woe «6 6 © . Hydraulic load limit oo = <2 Pneumatic control ON - OFF a Proportional pneumatic control _ = = 5 = = © S Electrica load limit ce i letrohydauiic control ON-OFF (12-24 Ve) <= = Electrohydraulc control PROP. (12-24 Vc) i. - < . w © lectropneumatic control (12-24 Vdc) 2 . AUXILIARY VALVES Antishock valve 7. « « + + « © « me Anticavitation valve . 7°. « « « +» « «© © Me Combined valve soe oe es ee . a. Pilot combined valve . es eee D25 [f SECTIONAL VALVE GENERAL INDEX 4) General specifications ‘Standard working conditions Fluid options 51) Order example ‘Standard thread Thread codes Tie-rod kit classification Painting 7) Dimensions 8 Typical curves Pressure drop (P - 7) Pressure drop (P - A/8) Pressure drop (A/B - T) rect relief valve curve Pilot Combined valve curve ‘Anticavitation check valve curve 10) Inlet Section ‘Order example Inlet side classification Valve identification Valve arrangement Inlet position and available thread type 43) Working section Order example ‘Spool identification ‘Spool actuation cissiication for manual control ‘Spool actuation classification for hydraulic control ‘Spool return action classification - Spring load values Work section identification ‘Auxiliary valves identification 20) Intermediate inlet section Order example Intermediate inlet section classification Vaive identification on intermediate inlet section Valve arrangement on intermediate inlet section Inlet position and available thread type 23) Intermediate outlet section Order example Intermediate outlet section classification Inlet position and available thread type (for BF intermediate) Inlet position and available thread type (for 8G intermediate) 25) Outlet section (version 1 outlet) Order example 25) Outlet section (HPCO version outlet) ‘Order example - HPCO version outlet ‘Outlet with single tank classification ‘Outlet with two tanks classification ‘Carry-over connection (HPCO) 29) D25 Spare parts list Gasket kits Installation General conditions and patents ao SECTIONAL VALVE J D25 Eason Description ‘Ambient operating temperature range Kinematic viscosity range ‘Max contamination level Recommended filtration level Internal filter (on electroproportional valves pilot line) ‘Standard working conditions value 40°C / +60°C 10 + 300 «st 9 (NAS 1638) - 20/18/15 (150 4406:1999) bio > 75 (10 16889:2008) 30 um All information and diagrams in this catalogue refer to @ mineral base oil VG46 at 50°C temperature (32 cSt kinematic viscosity) ‘Types of fluid (according to 10 6743/4) and Solutions Mineral Oil HL, HM (or HLP acc. to DIN 51524) Cl in water emulsions HFA Water in oll emulsions HFB Polyalycol-based aqueous solution HFC Fluid options Temperature (°C) = ze Compatible gasket 25 +80 NBR 45 455 NBR +5 +55 NBR. 10 +60 NBR For special applications and different fluids, please call our Technical Department. on D25 | SECTIONAL VALVE ORDER EXAMPLE Dom TPE: 'D25: product type (1: working section number 1) INLET ARRANGEMENT: pag. 10 1R 009 Inlet side and valve type 150 setting (bar) AGo7 Inlet position and available thread type 2) WORK SECTION ARRANGEMENT: pag. 14 woo1a spool type Ho0s spool actuation type RP .GO7 type and thread section 01 PA 100 auxiliary valve (port A) 01 PB 100 auxiliary valve (port B) 3) OUTLET ARRANGEMENT: pag. 28 D outlet type . AGos ‘outlet position and available thread type Ordering row 2 must be repeated for every work section Standard thread ‘The connection ports size is indicated by an ordering code common for all Hydrocontrol products. Following table shows all available connections; for ordering code refer to table on page xx. ports se (150-228) Ut-UNe (0-725) ‘SAE 3000 (150 6362-1) ‘SAE 6000180 6162-6) ThletPort(P) crye-cr2 Go7-cos 38 2UF —UO7—AMA-Y'yRUNC 07-508 TTHALITUNC ——S35-536 Ports(A-8) GIY#-GYI2 GO7-cos 1'98-12U" —UO7_—T/AMA-YRUNCSO7-S08—MA-ITUNC 835-536 Outlet) = GWG yB-RU uo? MA-ri2UNCS0s-s10 S Conryover(WPCO) GTI? «GOB 'YB-12UF © UO7—'/PMA-Y/2UNC SO9-SL0 THAMA-TMUNC $97-898 HHyaauiepict = Cys, G2 ese =a * - PoeumaticPlot G8 err yea SECTIONAL VALVE J D25 Tie-rod kit classification (appendix A”) Tle rod kit allows the correct assembly of sectional valves. Tle rod's lenath depends on the number of sections; each valve is assembled with tie rod kits including a tie rod, two nuts and two washers. 025 requires 4 tle-rod kits. The rod kit Order Cod Lenght (mm) Clamping Torque (Nm) Quantity ast 300109001 276 25/2 300109002 350 25/3 300309003 426 pasa 300109004 498 25/5 300309005 572 25/6 300108006 646 40 ; 25/7 300109007 720 25/8 300109008 794 25/9 300309009 868 25/10 300109010 942 pas/it 300109011 1016 bas/i2 300109012 1090 Painting (On request, all Hydrocontrol valves can be delivered painted (RAL 9005 black primer). Order example of D25/1 painted: bas/ IR.009 150.4 GO7 \WO01A HO06 RP GO7 01 PA 100 01 PB 100 TAGOS Po06/1 N10 “The painting I indicated with the following value: P06 - /1 - N10 L color back section number Painted D25 [f SECTIONAL VALVE (365) 153 136 (aay 1045 26.5 ont (422) 12) 4 | i i | Las Las} ! ~ 2 © ree ARP ws 7 wo pe x (mm) 225299 373-47 «SDL 505 66D 743.7 S——1030 Yom 29 m3 397 a7 SAS GID. 767 OL OIS 891053 ‘Weights (ka) 41,3 568 72,3 87,8 103.4 119 1344 150 655 181 1965 212, SECTIONAL VALVE J D25 od Indicated values have been tested with standard sectional valve and WOO1A spool, Pressure drop (P - T) * a pasiiz 9p ns pas passe \ nn) 700 Setting ranges type pressure (bar) A 0-350 a D25 [j SECTIONAL VALVE ene Indicated values have been tested with standard sectional valve and WOOLA spool. Antishock valve curve Setting ranges *~ pressure (bar) a _ set atfull flow at min. flow wale A 0-70 0-A/ 50-8 solm iaaes A 74-120 SEA TOA mie eee B 121-150 7A 110-8 ale © 151-300 IFA 240-8 ee ee D 301-350 24-A/ 350-8 Sear ee ne el? Combined valve curve Setting ranges pressure (bar) SYPE at full ow at min. flow A 50-130 -20-A/ 100-0 B 131-220 40K / 220-8 © 221-260 22-A/ 350-8 aa eee oll SECTIONAL VALVE J D25 IR 1. 009 150 2. AGO7 Rif, Code 1 009 019 AGo7 Auo7 ASO? AS35 Prac Order example Inlet side classification valve arrangement: setting (ber) Inlet position and available thread type Description Page ‘Sectional valve with right inet section Sectional valve with left inlet section a Pilot operated pressure relief valve Pilot operated pressure relief valve and Main anticavitation check valve 12 Without valves Upper inlet (thread G 1"1/4) Upper inlet (thread 1°5/8 - 12 UNF) Upper inlet (thread SAE 3000 1"1/4 MA) Upper inlet (thread SAE 6000 1” MA) 13 NOTE: when ordering a relief valve itis necessary to specify factory setting (example 150). oan 10 D25 [j SECTIONAL VALVE Inlet side classifications Sectional valve with right inlet section BAY Valve arrangement ~w description Pilot operated pressure relief valve Relief valve plugged Main anticavitation ‘check valve Sectional valve with right Inlet section type schema layout description 2 stage pilot operated relief valve 5 Externaly piloted valve Plug with pressure-gauge connection a ei er 009 Combination valve 2A Pressure relief valve in port A 3B Relief valve plugged in port B ‘The code identifies: with a number, the type of valve; with a letter its position ‘on the inlet section, (A) = spool action side (®) = spool return action side NOTE: when ordering a main relief valve itis necessary to specify setting fe NOTE: Valve combinations 021, and 038 requir. 038 200*380 VALVE COMBINATION INLET SECTION Wy is KF 068 ete valve combination double range setting (bar) my, 018 029 SECTIONAL VALVE J D25 Valve type on port B So Weg Me 3 4 5 6 009 010 on 019 020 021 022 030 031 032 double setting (see example). Order example for inlet section: oan J 2 Se a o16 027 IR 038 200*280 A GOS D25 [j SECTIONAL VALVE AGo7 AGOs Auo7 ASso7 ASos AS35 AS36 BGO7 BGos Bu07 BSO7 Bos Bs35 BS36 G07 Gos cuo7 cso7 csos cs35 cs36 DGo7 pcos Duo7 Dso7 Dsos Ds35 Inlet combination and thread available niet (P) Upper inlet (thread 61/8) Upper inlet read 6 17172) Upper inet (thread 15/8 = 12 UNF) Upper inlet (thread sae 3000 = 17/6 MA) Upper inet (thread SAE 3000 »1"1/4 UNC) Upper inet (thread SAE 6000 = 1° MA) Upper inet (tread SAE 6000 1° UNC) Upper inlet Pt with pressure-gauge connection G 1/4 (thread 6 1"1/4) Upper inlet Pi with pressure-gauge connection G 1/4 ‘tivese.G 1/2) Upper inlet Pa with pressure-gauge connection G 1/4 (Ceveae 1°58 12 UNF) Upper inlet Pa with pressure-gauge connection G 1/4 (Qhread SAE 3000" 11/4 MA) Upper inotP1 with pressure-gauge connection G 1/4 (thread SAE 3000 = "1/4 UNC) Upper inlet P with pressure-gauge connection G 1/4 (Cheed SAE 6000 = 1" MA) Upper inlot Pa with pressure-gauge connection G 1/4 {(iread SAE 6900 - 1" UNC) contrat sie inet (thread 6 °1/4) Central side inlet ‘hese G 1°72) ‘Centra sce inet (tered 1°58 = 12 UNF) Central side inlet (Whread SAE 3000 1"1/¢ MA) Central side inlet (thread SAE 3000 = 11/4 UNC) Central side inlet (thread SAE 6000 = 1° WA) Central sie inet (erreag SAE 6000 “1° UNC) ‘Central side inlet Pt with pressure-gauge connection G 1/4 (thread G3°1/4) Contra side inlet P2 with pressure-gauge connection G 1/4 ‘ehress G 1/2) Centra side inlet P1 with pressure-gauge connection 1/4 (teveag 1°58 = 2 UNF) ‘Central side inlet Px with pressure-gauge connection G 1/4 (Whread SAE 3000 = 111/8 MA) ‘Central side inlet Pt with pressure-gauge connection G 1/4 (Qhread SAE 3000 -1°1/4 UNC) ‘Central side inlet Pt with pressure-gauge connection G 1/4 (Chread SAE 6000-1" MA) ‘Central side inlet Pt with pressure-gauge connection G 1/4 {thread SAE 6000 1” UNC) 13 Jom Rit, SECTIONAL VALVE J D25 woo1a Hoos RP GO7 01 PA 100 01 PB 100 Code ‘woot ‘wooz RP GO7 RP UO7 Rs Go7 Rs u07 01 PA 100 05 PA 01 PB 100 05 PB Mena Order example: spool type spool actuation type section and thread type ‘auxiliaty valve (port A - handle side) ‘auxiliaty valve (port B - cap side) Description 3 positions double-acting 3 positions double-acting A-B to tank Unprotected lever hydraulic actuation Parallel circuit (G 1"1/4) Parallel circult (1”5/8-12 UNF) Series circuit (6 1"1/4) Series circuit (1"5/8-12 UNF) ‘Antishock valve (port A) Prearrangement for auxliary valve (port A) ‘Antishock valve (port 8) rearrangement for auxiliary valve (port B) ) Leave out the spool return action code when choosing HOO6. Page 15 v7 2 Sections designed to house auxiliary valve option require double choice on work ports A and B. ‘Always indicate setting value when using Antishock and Pilot combined valve: 01 PA (100) - 04 PA (100) D25 [j SECTIONAL VALVE Spool identification order example of spool: W001 A 310 WO01 spool schema 3 positions double-acting A spool type standard spool 310 restricted service ports restriction on diameter (0,10 mm in A and B) W001 © —_3 positions double-acting W002 —_3 positions double-acting A and B to tank i 3 positions double-acting A to tank B blocked i 3 positions double-acting A blocked B to tank WO0S 3 positions single - acting on A WOD6 —_3 positions single - acting on B W009 —_ 3 positions doub acting with anticavitation valves W010 3 positions double-acting switch port closed (A - B blocked) W011 3 positions double-acting switch port closed (A B to tank) r W012 —_4 positions double-acting with floet in the 4" position ott 3) W013 3 positions double-acting regenerative WO15 3 positions double-acting series WO16 3 positions double-acting series A and B to tank 15 Jos code 310 K10 Y10 NoTE: clreutt A-BINT AINT BINT CODE woo. woo2 woos woos: woos wo10 wou wo12 wo13 wo1s wo1s SECTIONAL VALVE J D25 ‘spools with restricted service ports restriction on dlameter (mm) section (mm?) __hydraullc schema 0,10 471 Ares. 010 an wats 0,10 an 1 wae spool type avail STANDARD METERED a B woo. woos woo2a woo26 woo3a wo03s woos woos woos woos woosa woos, woos woos, wor wou wo12a wo134 worse wo1sa = W012, W013, spools need a special machining on the valve body. = WO15, W016, spools need RS type body. = Float spool (W012) need special detent kit (F005). = Regenerative spool (W013) need speci return spring kits. = Different spools are available on request. Plaese contact our Sales department for more information. oan 16 D25 [f SECTIONAL VALVE Spool actuation classification for manual control code description dimensions configuration H101 ——_ Unprotected lever Unprotected lever ee rotated 180° ‘Spool actuation classification for Hydraulic control code description dimensions ‘configuration Hydraulic actuation with side ports ‘and cast-iron end caps = P ports = 61/4 UF port = 9/168 UNF Hydraulic pilot control curve ‘The diagram shows the spool stroke as a function of the pressure operating coa-Sce tron es oan el v7 Jom SECTIONAL VALVE J D25 ‘Spool return action classification - Springs load values ‘Spool return kits have three different sprong types; following the codes depending on spring loads. Spring type Code A standard spnng) (Soft spring) © (heavy spring) Pena JAH! Preloading 155 116.7 N 188.3 N Endofstroke —373.7N 152N 454.3 N ‘Spool return action Identification example Etisal code Foo1A Foos Fooic iti Spool return action classification description schema dimensions ‘configuration 3 positions FOOAB spring-centred spool Fooic 3 positions FOO2A spring-centred spool detent in Aand 8 3 positions FOO3A spring-centred spool detent in A 3 positions: FOO4A spring-centred spool detent in B 4 positions: spring-centred spool FOOSA detent in 4% position (only for W012 spool) ‘SECTIONAL VALVE ‘Compatibility table RP.GO7 RP Gos RP UO7 RP S07 RP SOs RP S35 RP S36 SECTIONAL VALVE J D25 Work section identification working section type Paralle! ‘drcult section When the spoo! Is operated It intercepts the by-pass gallery by diverting the flow of oll to service port A or B. If two for more spools are actuated at the same time, the oll wll power the service port that has the lower load; by throttling the spools, the flow of oll can be divided between two or more service ports. RS GO7 RSGos RS UO7 RS S07 RSSO8 RS S35 RS S36 AB al I Series i jor = | j co \When the spoo! is operated it intercepts the switch gallery by diverting the flow of oll to service port A or B. The oll that flows back from the actuator Is carried to the switch gallery thus making It avalable to the service ports downstream from the series section. The pressure drop downstream is added to the pressure drop of the section itself. D25 | SECTIONAL VALVE Auxiliary valve identification code 01 PA 02 PA 04 PA code 01 PB 05 PB description Antishock valve (port a) Anticavitation valve (port a) Pilot combined valve (port a) Prearrangement for auxiliary valve (port A) description Antishock valve (port 8) Anticavitation valve (port 8) Pilot combined valve (port B) Prearrangement for auxiliary valve (port 8) schema BY schema BY Auxiliary valve - Setting range ‘Sections designed to house auxiliary valve option require double cholse on work ports A and B. configurs 233% configuration 233% type mooa> type mooaD> ‘setting range (bar) atfull flow type at min. flow 0/70 74/320 321/150 151/300 301 / 350 30/110 111/350 A B c > E 0-8 / 50-A, S1-A/ 70-4, Ti / 110-0 ALLA 240-8 241-4 / 350-8 setting range (bar) at full flow 0/70 71/120 121/150 1s /300 301 / 350 30/110 111/350 Always indicate setting value when using antishock valve and pilot combined valve: 01 PA (120) = setting at full flow (01 PA (120-A) = setting at min. flow setting at min. flow (04 PA (120) a1 [Joe type A B c > E at min, flow 0-8 / 50-8, Si-A/ 70-4, TA / 110-8 LILA / 240-8 241-4 / 350-8 SECTIONAL VALVE J D25 Mines o aed Order example BE Inlet side 009 valve arrangement 150 setting (bar); when ordering a main relief valve it is necessary to specify setting — AGO7__ inlet position and available thread type Rif, Code Description Page ad Intermediate inlet section a Bye Intermediate inlet section with pressure relief valve 009 Pilot operated pressure relief valve 1. 010 Pilot operated pressure relief valve and Main anticavitation check valve 019 Without valves 020 Main anticavitation check valve = 2 4907 Upper inlet (thread G 1"1/4) Auo7 Upper inlet (thread 1°5/8-12 UNF) NOTE: when ordering a relief valve itis necessary to specify factory setting (example 150). * = omit the code for inlet positioning and thread oan J 22 D25 [j SECTIONAL VALVE Intermediate inlet section classifications Intermediate inlet type BE Intermediate Inlet section ‘at | A 3 PL ‘The intermediate inlet section is driven by two pumps (P + Pt). The downstream elements can be set toa lower pressure than the upstream ones by adjusting the pressure relief valve of the intermediate section in question, Intermediate Inlet section with pressure relief vialve BV 54 ‘The intermediate iniet section and the elements are driven by a single pump (P). The downstream elements can be set to @ lower pressure than the upstream ones by adjusting the pressure relief valve of the intermediate section in question. Valve identification on intermediate inlet section type schema layout description type schema _configurazione _descrizione @ Pilot operated Externaly 2 @ pressure 1G" piloted relief valve valve Plug with Relief valve * 3 Co plugoed al Xe pressure-gauge connection Valve arrangement on intermediate inlet section enn ane ee ey 009 Combination valve 2A Pressure relief valve in port A 3B Relief valve plugged in port B ‘The code identifies: with a number, the type of vaive; with a letter its posi- tion on the inlet section. (A) = spool action side (®) = spool return action side NOTE: when ordering a main relief valve itis necessa~ ry to specify setting 23 Jon SECTIONAL VALVE J D25 Valve type on port B concmaron ©, Ch Vy op 2 INLET SECTION 3 4 Cm, 2 009 010 «016 @ 4 029 «030 Sem 085 oss Valve type on port A Inlet combination and thread available AGO7 Inet (P1) AGos AvO7 ‘ASO7 Upper iniet ASo8 AS35 AS36 IR 009 150 A G07... -- Right inlet section \WO01A 006 RP G07... .- Working section BE 009 150 A Go: {Intermediate inlet section \WOO1A H006 RP G07... + Working section TIA G08... .- Outlet section IR 009 150 A G07... -- Right inlet section \WO01A H006 RP G07. +. Working section BV 009 150 Intermediate inlet section \WOO1A H006 RP G07. Working section TIA G08, Outlet section on ff 24 D25 | SECTIONAL VALVE Ps ee) Grae Order example BF inlet side 1. AGOB__ inlet position and available thread type Rif. Code Type Description Page oF Intermediate outlet section with single tank return BG Intermediate outlet section with two tank returns ‘Gos Upper outlet (thread 6 1"1/2) ‘Auo7 Upper outlet (thread 1°5/8-12 UNF) G08 — for _Front outiet side A (thread G 171/2) as GU07 —_BF_ Front outlet side A (thread 1”5/8-12 UNF) 1 nos Rear outiet side 8 (thread G 1°1/2) Hu07 Rear outiet side B (thread 1°5/8-12 UNF) 3608 for Upper outlet HPCO - front side A and rear side B to T (thread G 4°3/2) 3U07 BG _Upper outlet HPCO-tron side A and rear side 6 to T (thread 1"°5/8-12 UNF) 25 Joe SECTIONAL VALVE J D25 Intermediate outlet section classifications intermediate outlet type Intermediate outlet section with single tank return Intermediate outlet section with two tank returns ‘The section in question allows the flow of oil of the two pumps to be piped in two outlets: HPCO for powering ano- ther directional control valve, T for discharge of the work ports. In order to obtain this, the two T need to be linked. AGos S09 Asio Gsi0 HUu07 Outlet position and available thread type (for BF intemediate) ‘Outlet combination and thread available Upper outlet (7) Front outlet side A(T) Rear outlet side 8 (T) D25 [j SECTIONAL VALVE Outlet position and available thread type (for BG intemediate) Inlet combination and thread available 1608 au Upper outlet HPCO. front side A and 3809 rear side BtoT 3s10 Complete configuration samples for D25/2 with intermediate outlet section (BF) 1R 009 150 A G07... . Right Inlet section ‘WOOLA H006 RP Go: .. Working section BFA GOs {Intermediate outlet section WOOLA H006 RP G07... ‘Working section 11.009 150 A G07... Left inlet section IR.009 150 A G7... Right inlet section WOOLA HO06 RP GO? ..n.en.nes Working section 8G3.Gos Pomn Intermediate outlet section ‘WOOLA H006 RP G07. Working section 11.009 150 A G07... Left inlet section 27 Joe SECTIONAL VALVE J D25 CMa NO ee) Order example 1, 72 outlet section type 2, AGOB outlet position and available thread type Rif, Code Description Page > ‘Outlet section with single return (T) right-side inlet (P) ™* (Outlet section with single return (T) left-side inlet (P) AGos Upper outlet (thread G 1°1/2) Auo7 Upper outlet (thread 1"5/8-12 UNF) Asoo Upper outlet (thread SAE 3000 - 1"1/2 MA) 20 2 Asi0 Upper outlet (thread SAE 3000 - 1"1/2 UNC) ccos Central outlet (thread G 1”1/2) cuo7 Central outlet (thread 1°5/8-12 UNF) soo Central outlet (thread SAE 3000 - 1"1/2 MA) csi0 Central outlet (thread SAE 3000 - 11/2 UNC) Sa Order example - HPCO version Outlet Eo 1, TM outlet section type 2, M.GO7 outlet position and available thread type: Rif, Code Description Page . ™ ‘Outlet section with two return (T-HPCO) right-side inlet (P) ™ Outlet section with two return (T-HPCO) left-side inlet (P) Mos HPCO upper outlet T (tank) rear outlet side B (thread G 1"1/2) Muo7 HPCO upper outlet T (tank) rear outlet side B (thread 1°5/8-12 UNF) Mso9 HPCO upper outlet T (tank) rear outlet side B (thread SAE 3000 -1°1/2MA) 3g Msi10 HPCO upper outlet T (tank) rear outlet side B (thread SAE 3000 - 1°1/2 UNC) 2 Neos HPCO upper outlet T (tank) front outlet side A (thread G 1"1/2) Nuo7 HPCO upper outlet T (tank) front outlet side A (thread 1°5/8-12 UNF) Noo HPCO upper outlet T (tank) front outlet side A (thread SAE 3000 - 1”1/2 MA) Nsi0 HPCO upper outlet T (tank) front outlet side A (thread SAE 3000 - 1°1/2 UNC) D25 [j SECTIONAL VALVE Outlet with single tank classification outlet identification nD Outlet section with single return (T) kK Outlet section with single return (T) right-side inlet (P) left-side inlet (P) ua no os AGos need ea) Auo7 comead F583 une) ASOS (corona SHPSOB8 E12 may ASO (enrene SAP%08 1/2 unc) Gos ied CE) cuo7 ces FSIS soo conreae SRE SOUR aya may csi0 tens SESS 2 unc) Gos reomesd iS Gu07 oly To cenroad PSS Uh Gsos ue een HBSS Sa ay Gsi0 cee SE SBI ESA, ancy Hos ead BS Huo7 “ues tain cen SSIS Edt Hso9 ie Cereal Bae Sb80 fo way Hs10 conrad SEG Po uncy 29 Joe SECTIONAL VALVE J D25 Outlet with two tanks classification outlet identification = Outlet section with two return (T-HPCO) a Outlet section with two return (T-HPCO) right-side inlet (P) left-side inlet (P) outlet combination and thread available seas a “ery aes ‘rea F172) eau ai weno? “irkte, PMO Trees oman ane Sneene esc ee? pogo core eas 223 eee sat aaa ia "aaa ieee con aR, = 3 22 i i 2 fe ona ET 20m neactenue eeumecs Q.sa7 Sat Gara |@ ean 0pm tet ex eat cae fsecss Q.s38 Tease GEES (2 ENT D25 [j SECTIONAL VALVE CARRY-OVER CONNECTION (HPCO) ‘This option, available on all 025, allows the sectional valve to feed a second valve, by extending the free flow channel. In this configuration, the valve need a separated port for connection to tank. code (HPCO Plug Identification) description aty 413010201 conic plug G 1/2 x 17 2 a1 [Jose SECTIONAL VALVE J D25 Pees Description Ordercode Qty Code Note 30168 ‘Seteng: 300 bar Plot operatad pressure rel valve (*) 313 1 Setng: 200 bar 4383 ‘Seting: 300 bar eet velve puopee 4s0i0s001 1 - Nain Ancavtatin check ae sisososo1 vera plot valve sisososo1 ug with presur-gauge connection 40105002 421208015, woot 3 pons doubleactng spol 42200291 WOOL 421208003, woota for erate acuaton 4421208007 ‘woo2a 3 pasos doubleating A and Bt tak sooo) aziz0902 1 WOO 421205004, ‘woo2a for era euaton 3 postions sngl-ating on A z1z08022 1 WOO 3 pestis sncle-ating on 8 4712050231006 a 421205018 4 postion oubleacting with Hatin the 4 tam} MORAL Euan 320308001, ima Le 320209003, — nly or WO12 spot zaosogo01 2 {or 8S version 320505006 oly for WOE2 spol = fr BSP version Hydrate acuaton wth site pots mesmo 2tC(tiO for UNF version s20so00t7 ony for WOI2 spol fr UNF version oan IJ 2 ae D25 [j SECTIONAL VALVE Descrition 3 postion sing centred soot Detenin Mand etenin A Detetin 8 Dentin 4 poston Check vate onthe work secton Arishack vive on prt A iain vate on port it combine valve on par A Premrangenent for ary vale on part Anshock valve on port ication von pore 8 Pot combine va on por 8 Prearangerent or uly vale on part 8 Pug (6 114) Pug i (1°5/812 UNF) amen ‘1080802 15808 sos 307 260 ama ‘1sos0e0: 5001 ‘30409008, ‘30000022 ‘300009002 3 Joe OLA 02a 4A 04s 058 cor Note nly for WOI2 spot ony for R and secten Seng: 100 bar setting: 200 ba setting: 300 bar Seng: 100 bo setting: 200 bar sting: 200 bar Setting: 100 bar setting: 200 bar setting: 200 bar Setting: 100 bar seting: 200 ber sting: 300 bar SECTIONAL VALVE J D25 eae Inlet section Complete gasket kit Inlet and work section Rit, Order code Description Qty 1 423401017 c Ring 4 a 412020603 ‘O.R. 90SH (2-129) 4 Complete Gasket kit: order code - 350909001 on 34 D25 | SECTIONAL VALVE TS Ch Guidelines = Mount the control valve securely to a flat surface (recommended 3 point fixing); at the time do not use a hammer to positioning by hitting = When handling the control vaive, be careful not hold the pilot cover or return spring cap of the spool or accessory valves such as main relief valves and anti-shock relief valves. ~ Clean piping materials sufficiently before use. = Make sure to prevent the port openings from being entered with dust or foreign matters. = Tighten the port connectors surely with the recommended fastening torques. = Do not direct the jet of a pressure washing unit directly to the vaive, Fittings tightening torque (Nm) thread type port P Port A- 8 PortT BSP (150 - 228) eriy2 e112 oraz with rubber sealing (DIN 3869) 120 320 120 with copper or steel and rubber washer 120 120 120 BSP (150-228) e1i4 ery e114 with rubber sealing (DIN 3869) 120 320 120 With copper or steel and rubber washer 120 120 120 UN-UNF (180 - 725) 21/1612 UNF 11/1612 UNF 1”1/16 12 UNF with OR. 120 120 120 UN-UNF (ISO - 725) 2°5/1612 UNF 15/1612 UNF_——1°5/16 12 UNF with OR. 120 120 120 General clamping torque The following table provides the main tightening torques of the distributor 25: 35 Joe SECTIONAL VALVE J D25 Dimensions - Thread codes The connection ports size Is indicated by an ordering code common for all Hydrocontrol products. Following table shows all available connections. Ponacneke eee) Type MIMS MDH, MOTH Code Mot Moz Moz. Coie tec) Type war 3/8" 42" 3/8" a v4 vue 2 Code Go2 Go3 G04 Gos G06 G07 Gos Goo (OVA kec eee) S/I6" 18 UNF 4" LGUNF 7/8" I4UNF Y'Y/16 12UNF T'S/1612UNF _1°5/8 12 UNF Wes AES SAEB SAEIO. © SAEI2.—SAEI6.——SAE20, Code uo2 vos uo4a vos vos u07 Dimensions - SAE Flange codes Beto) wea" aan ataya aya a2 ttt (ma) (UNC) (MA) (UNC) (MA) (UNC) (MA) (UNC) (MA) (UNC) (MA) _ (UNC) Code S03 S04 S05 $06 S07 S08 S09 S10 Si1 Si2 Si5 S16 1 19 «25 02532 HBC SC HOG 476 476 «524 52,4 587 58,7 699 69.9 778 77,8 106,4 1064 22,3 22,3 262 26,2 30,2 302 357 357 429 429 619 61,9 MIO 3/816 MIO 3/8-16 MIO 76-14 MIZ_ 1/243 121/213. MI65/B-IL Type ooa> Beek yeaa" aa ats 13/2 1"1/2 (ma) (UNC) (MA) (UNC) (MA) (UNC) (MA) (UNC) Code S33 S34 $35 S36 S37 $38 S39 S40 19 8S KB 508 50.8 572 57,2 666 666 73,3 79,3 238 238 278 278 38 348 355 36,5 mio 3/816 MI2 7ibl4 M14 4/243, MIS 5/8-11 Type onoe> www.hydroma.cz www.hydroma.eu www.hidromasistems.p!

You might also like