You are on page 1of 84

6.

General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0403
Plain Bracket
End Switch for the cassette
The Part Number on the Label includes Hardware
Bezel Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0403 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01

1. Assembly FL-0403 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600 Bill; Plain Bracket; Cassette switch;
Housing FLH-0110

www.igrotechnics.ru
12pin JAE
A division of Bezel FLB-5011 Bezel, Handled Bill width 66 mm
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0403_D 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 NC VALIDATING HEAD AS SHOWN.

4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE: -0 to +50 degrees Celsius


TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0405
FEATURES: Fixed Width Validator Head
Plain Bracket
End Switch for the cassette The Part Number on the Label includes Hardware
Standard CashCode Bezel Part Number and Software Part Number.
Example
FL-0405 AA0000
ENCLOSURE: FL Bill Validator
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01
1. Assembly FL-0405 contents

Unit Unit Part No.: Unit Description


Validating Bill width 68 to 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1801U Set of Basic Sense-A-Click
-A- FLS-1801
FLS-1801L sensor packs;
Click
600 Bill; Plain Bracket; Cassette switch;
Housing FLH-0110
12pin JAE

www.igrotechnics.ru
CashCode Standard Bezel,
Bezel FLB-2331
CashCode Company Inc.
Handled Bill width 70 mm
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2004, CashCode Co. Inc PT# UG-FL-0405_B 06/04


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW#2 ON State OFF State Default Setting
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 9 600 bps 19 200 bps ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 green on red COM port CRC Error
1 2 3 4 5 6 2 green on red Internal CRC Error
3. Interface Connector Pin-out
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5 green on red Improper type of CCMS
6 green on red Download Error
Terminal Circuit
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0407
FEATURES: Fixed Width Validator Head
UDN Customized Plain Bracket
End Switch for the cassette The Part Number on the Label includes Hardware
Bezel Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0407 AA0000
User's Guide Software Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE Hardware Part Number

1. Assembly FL-0407contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01 Unit Unit Part No.: Unit Description
600, UDN Customized Plain Bracket no lock,
Housing FLH-0112
cassette switch, JAE
Power
FLP-9028 24V DC, RS-232, Coated PCB, Platform B
Interface
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCBs
Sense FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs; Coated PCB
Click
Bezel, Handled Bill width 66 mm,

www.igrotechnics.ru
Bezel FLB-9065
Coated PCB
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0407_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 GND 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
VALIDATING HEAD AS SHOWN.
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0408
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
Part Number and Software Part Number.
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette Example
FL-0408 AA0000
Two switches for the cassette and cassette Lock switch
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0408 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, Opto Isolated, Coated PCB,
FLP-9027
Interface Platform A
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs; Coated PCB
Click
600 Optional bracket for the cassette Lock;
Housing FLH-0820 Two Switches for the cassette and cassette
lock Switch; JAE connector;

www.igrotechnics.ru CashCode Company Inc.


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2006, CashCode Co. Inc PT# UG- FL-0408_A 05/06


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 9 600 bps 19 200 bps ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
5 green on red Improper type of CCMS
3. Interface Connector Pin-out 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE);
7 8 9 10 11 12
Contact DR-SC20-1-7000 (JAE).

Terminal Circuit
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0410
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


The Part Number on the Label includes Hardware
UDN Customized Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock Example
Standard CashCode Bezel FL-0410 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator Hardware Part Number
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH 1. Assembly FL-0410 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01 Unit Unit Part No.: Unit Description
600 Bill; UDN Customized Lock Bracket,
Housing FLH-0812
Cassette switch; 12pin JAE
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-0510
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
CashCode Standard Bezel,
Bezel FLB-2331
Handled Bill width 70 mm

www.igrotechnics.ru
CashCode Company Inc.
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2004, CashCode Co. Inc PT# UG-FL-0410_A 09/04


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW#2 ON State OFF State Default Setting
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 Reserved Reserved ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 green on red COM port CRC Error
1 2 3 4 5 6 2 green on red Internal CRC Error
3. Interface Connector Pinout
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
Contact DR-SC20-1-7000 (JAE). 5 green on red Improper type of CCMS
7 8 9 10 11 12
6 green on red Download Error
Terminal Circuit
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE: -0 to +50 degrees Celsius


TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0428
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Digital Display CashCode Bezel FL-0428 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0428 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head, Mega128,
FLV-0310
Head non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense FLS-1705U Set of Basic Sense-A-Click
-A- FLS-1705
FLS-1705L sensor packs;
Click
1000, lock bracket, cassette and lock switches,
Housing FLH-3510
JAE

www.igrotechnics.ru
CashCode Bezel with Digital Display,
Bezel FLB-3111
Handled Bill width 66 mm
CashCode Company Inc.
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2006, CashCode Co. Inc PT# UG-FL-0428_A 06/06


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE);
7 8 9 10 11 12
Contact DR-SC20-1-7000 (JAE). 5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 NC VALIDATING HEAD AS SHOWN.
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
(8102003)

Lock Washer M3, Internal Tooth, Zinc (1 pcs.)


(8203002)
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0430
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette
Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Bezel FL-0430 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0430 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
600, lock bracket, cassette and lock switches,
Housing FLH-0810
JAE
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-0510
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Bezel FLB-5831 Bezel, Handled Bill width 70 mm

www.igrotechnics.ru
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0430_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 GND PRECAUTIONS.
2 Reset-RS 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 Reserved VALIDATING HEAD AS SHOWN.

4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved

Screw M3x6, Phillips, Pan Head, Zinc (3 pcs.)


(8201000)
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0432
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Bezel Example
FL-0432 AA0000
ENCLOSURE: FL Bill Validator Software Part Number
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0432 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-0510
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Bezel with AGT customization,
Bezel FLB-5032
Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0432_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 GND PRECAUTIONS.
2 Reset-RS 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 Reserved VALIDATING HEAD AS SHOWN.

4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0433
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette
The Part Number on the Label includes Hardware
Two switches for the cassette and cassette Lock switch Part Number and Software Part Number.
Bezel Variant D
Example
FL-0433 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0433 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600 Optional bracket for the cassette Lock;
Housing FLH-0820 Two Switches for the cassette and cassette
lock Switch; JAE connector;

www.igrotechnics.ru
Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0433_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
only. See Software Description document for exact switches and jumpers settings. 1 red on black Cassette is out of position
OFF State Wrong Sense-A-Click type or communication with
SW. #1 ON State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON
3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 9 600 bps 19 200 bps ON
13 red on black Transport Motor overload
To work with a “Host
SW 2.4 Service OFF 1 green on red COM port CRC Error
Machine Controller”
2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6
3. Interface Connector Pinout 5 green on red Improper type of CCMS
6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Terminal Circuit 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0434
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette
The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Bezel Variant D
Example
FL-0434 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0434 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;

www.igrotechnics.ru
JAE connector;
Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0434_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0435
FEATURES: Fixed Width Validator Head
Plain Bracket
The Part Number on the Label includes Hardware
End Switch for the cassette Part Number and Software Part Number.
Bezel Variant D
Example
FL-0435 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0435 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600 Bill; Plain Bracket; Cassette switch;
Housing FLH-0110
12pin JAE

www.igrotechnics.ru
Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0435_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0436
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
UDN Customized Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Bezel FL-0436 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0436 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
600 Bill; UDN Customized Lock Bracket;
Housing FLH-0812
Cassette switch; 12pin JAE
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-0510
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Bezel FLB-5031 Bezel, Handled Bill width 70 mm

www.igrotechnics.ru
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0436_E 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 GND PRECAUTIONS.
2 Reset-RS 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 Reserved VALIDATING HEAD AS SHOWN.

4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0437
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
UDN Customized Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Bezel FL-0437 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0437 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
600 Bill; UDN Customized Lock Bracket,
Housing FLH-0812
Cassette switch; 12pin JAE
Power
FLP-9069 24V DC, CCS-VFM, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-0510
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Bezel FLB-5031 Bezel, Handled Bill width 70 mm

www.igrotechnics.ru
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0437_C 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 GND PRECAUTIONS.
2 Reserved 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 Reserved VALIDATING HEAD AS SHOWN.

4 Signal Ground
5 LED Power
6 DATA
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 ACCEPT
11 INTERRUPT
12 SEND
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0439
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette
End Switch for the cassette and cassette Lock The Part Number on the Label includes Hardware
Part Number and Software Part Number.
Bezel Variant D
Example
FL-0439 AA0000
ENCLOSURE: FL Bill Validator
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0439 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;

www.igrotechnics.ru
Bezel Variant D, Handled Bill width 66
Bezel FLB-9074
mm, Coated PCB
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0439_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
only. See Software Description document for exact switches and jumpers settings. 1 red on black Cassette is out of position
OFF State Wrong Sense-A-Click type or communication with
SW. #1 ON State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON
3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON
13 red on black Transport Motor overload
To work with a “Host
SW 2.4 Service OFF 1 green on red COM port CRC Error
Machine Controller”
2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout
6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Terminal Circuit 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0443
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Bezel Variant D
FL-0443 AA0000

ENCLOSURE: FL Bill Validator Software Part Number


User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0443 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01 Unit Unit Part No.: Unit Description
600 Bill; Lock Bracket; Cassette switch;
Housing FLH-0810
12pin JAE
Power
FLP-9028 24V DC, RS-232, Coated PCB, Platform B
Interface
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCBs
Sense FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs; Coated PCB
Click
Bezel Variant D, Handled Bill width 66 mm,

www.igrotechnics.ru
Bezel FLB-9074
Coated PCB
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0443_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0445
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


The Part Number on the Label includes Hardware
Plain Bracket Part Number and Software Part Number.
End Switch for the cassette Example
Runway Lights CashCode Bezel FL-0445 AA0000
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
1. Assembly FL-0445 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
Housing FLH-3110 1000, no lock, cassette switch, JAE
CashCode Runway Lights Bezel,
Bezel FLB-9059
Handled Bill width 66 mm, Coated PCB

www.igrotechnics.ru CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2006 CashCode A Crane Co. Company PT# UG-FL-0445_A 11/06


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 NC VALIDATING HEAD AS SHOWN.

4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
(8102003)

Lock Washer M3, Internal Tooth, Zinc (1 pcs.)


(8203002)
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.
Front Loaded Bill Validator

OPERATING TEMPERATURE: -0 to +50 degrees Celsius


TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0447
Bracket for optional Lock for the cassette
End Switch for the cassette and cassette Lock
The Part Number on the Label includes Hardware
Bezel Variant A Part Number and Software Part Number.
Example
FL-0447 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0447 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;

www.igrotechnics.ru
JAE connector;
A division of
Bezel Variant A,
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3 Bezel FLB-5211
TEL: (905) 303-8874, 1(800)-584-2633 Handled Bill width 66 mm
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0447_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE: -0 to +50 degrees Celsius


TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0448
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Standard CashCode Bezel Example
FL-0448 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
Hardware Part Number
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0448 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1705U Set of Basic Sense-A-Click
-A- FLS-1705
FLS-1705L sensor packs;
Click
1000, lock bracket, cassette and lock
Housing FLH-3510

www.igrotechnics.ru
switches, JAE
CashCode Standard Bezel,
Bezel FLB-2311
Handled Bill width 64...66 mm
CashCode A Crane Co. Company
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2006 CashCode A Crane Co. Company PT# UG-FL-0448_A 12/06


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example
only. See Software Description document for exact switches and jumpers settings. ## of flashes Malfunction
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
2 red on black
Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
6 red on black Failure of optical sensors
7 red on black Failure of magnetic sensors
SW#2 ON State OFF State Default Setting 8 red on black Transporting motor failure (timeout)
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 Reserved Reserved ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 2 3 4 5 6 1 green on red COM port CRC Error
3. Interface Connector Pinout 2 green on red Internal CRC Error
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
7 8 9 10 11 12
Contact DR-SC20-1-7000 (JAE). 5 green on red Improper type of CCMS
6 green on red Download Error
Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0451
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Bracket for optional Lock for the cassette Example
End Switch for the cassette and cassette Lock FL-0451 AA0000
Runway Lights CashCode Bezel Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock; Part # OPT-MKFL-FLH
1. Assembly FL-0451 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;
CashCode Runway Lights Bezel,

www.igrotechnics.ru
Bezel FLB-9059
Handled Bill width 66 mm, Coated PCB

CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2007 CashCode A Crane Co. Company PT# UG-FL-0451_A 01/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 NC VALIDATING HEAD AS SHOWN.

4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
(8102003)

Lock Washer M3, Internal Tooth, Zinc (1 pcs.)


(8203002)
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0452
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Bracket for optional Lock for the cassette Example
End Switch for the cassette and cassette Lock FL-0452 AA0000
Standard CashCode Bezel Software Part Number
Hardware Part Number

ENCLOSURE: FL Bill Validator


User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH 1. Assembly FL-0452 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;
CashCode Standard Bezel,

www.igrotechnics.ru
Bezel FLB-2311
Handled Bill width 66 mm,

CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG-FL-0452_A 01/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12

Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0453
Bracket for optional Lock for the cassette
End Switch for the cassette and cassette Lock
Bezel Variant A The Part Number on the Label includes Hardware
Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0453 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0453 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
1000, lock bracket, cassette and lock
Housing

www.igrotechnics.ru
FLH-3510
switches, JAE
Bezel Variant A,
Bezel FLB-5211
A division of Handled Bill width 66 mm
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0453_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0454
Plain Bracket
End Switch for the cassette
Bezel Variant A The Part Number on the Label includes Hardware
Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0454 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01
1. Assembly FL-0454 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Housing FLH-3110 1000, no lock, cassette switch, JAE

www.igrotechnics.ru
Bezel Variant A,
Bezel FLB-5211
A division of Handled Bill width 66 mm
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0454_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0455
Bracket for optional Lock for the cassette
End Switch for the cassette and cassette Lock
Bezel Variant D The Part Number on the Label includes Hardware
Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0455 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0455 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
1000, lock bracket, cassette and lock
Housing

www.igrotechnics.ru
FLH-3510
switches, JAE
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
Bezel FLB-5217 Bezel Variant D, Handled Bill width 66 mm
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0455_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0457
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Bracket for optional Lock for the cassette Example
Two switches for the cassette and cassette Lock switch FL-0457 AA0000
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0457 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 70 mm, Mega128, non-coated
FLV-0510
Head PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600 Optional bracket for the cassette Lock;
Housing FLH-0820 Two Switches for the cassette and cassette
lock Switch; JAE connector;

www.igrotechnics.ru
CashCode A Crane Co. Company
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG-FL-0457_A 03/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW#2 ON State OFF State Default Setting
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 9 600 bps 19 200 bps ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 green on red COM port CRC Error
1 2 3 4 5 6 2 green on red Internal CRC Error
3. Interface Connector Pinout
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5 green on red Improper type of CCMS
6 green on red Download Error
Terminal Circuit
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
6. General Specifications: FL Bill Validator
CURRENCY AND INTERFACES See Software Description document
User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0458
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Runway Lights CashCode Bezel FL-0458 AA0000
Software Part Number

ENCLOSURE: FL Bill Validator Hardware Part Number


User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1 1. Assembly FL-0458 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01
Validating Bill width 70 mm Validating Head,
FLV-9016
Head Mega128, Coated PCBs
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1707U Set of Basic Sense-A-Click
-A- FLS-1707
FLS-1707L sensor packs, Coated PCB
Click
1000, lock bracket, cassette and lock
Housing FLH-3510
switches, JAE
CashCode Bezel with Runway Lights,
Bezel FLB-9130
Handled Bill width 70 mm, Coated PCB

www.igrotechnics.ru CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2007 CashCode A Crane Co. Company PT# UG- FL-0458_A 03/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings. Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON 4 red on black Mechanical jam in the cassette (stacking motor can not stack the bill)
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 10 red on black Failure of Aligning motor or sensor
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 11red on black Bill pathway latch is not empty (bill is jam)
Banknote jammed in the entry slot of the cassette and credit were not
12 red on black
SW#2 ON State OFF State Default Setting issued
SW 2.1 Four Way One Way ON 13 red on black Transport Motor overload
SW 2.2 Reserved Reserved ON 1 green on red COM port CRC Error
SW 2.3 Reserved Reserved ON 2 green on red Internal CRC Error
3 green on red Improper CCMS format
To work with a “Host
SW 2.4 Service OFF 4 green on red CCMS is absent
Machine Controller”
5 green on red Improper type of CCMS
6 green on red Download Error
5. CashCode Bezel Installation
1 2 3 4 5 6 WARNING
3. Interface Connector Pinout
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Mating Connector: DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Socket DR-12-2SC-FO (JAE); 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
PRECAUTIONS.
3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
VALIDATING HEAD AS SHOWN.
Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
9 RXD (8102003)
10 NC
11 NC Lock Washer M3, Internal Tooth, Zinc (1 pcs.)
(8203002)
12 NC
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
6. General Specifications: FL Bill Validator
CURRENCY AND INTERFACES See Software Description document
User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0459
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Runway Lights CashCode Bezel FL-0459 AA0000
Software Part Number

ENCLOSURE: FL Bill Validator Hardware Part Number


User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH 1. Assembly FL-0459 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01
Validating Bill width 70 mm Validating Head,
FLV-9016
Head Mega128, Coated PCBs
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1707U Set of Basic Sense-A-Click
-A- FLS-1707
FLS-1707L sensor packs, Coated PCB
Click
Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;
CashCode Bezel with Runway Lights,

www.igrotechnics.ru
Bezel FLB-9130
Handled Bill width 70 mm, Coated PCB

CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2007 CashCode A Crane Co. Company PT# UG- FL-0459_A 03/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings. Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON 4 red on black Mechanical jam in the cassette (stacking motor can not stack the bill)
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 10 red on black Failure of Aligning motor or sensor
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 11red on black Bill pathway latch is not empty (bill is jam)
Banknote jammed in the entry slot of the cassette and credit were not
12 red on black
SW#2 ON State OFF State Default Setting issued
SW 2.1 Four Way One Way ON 13 red on black Transport Motor overload
SW 2.2 Reserved Reserved ON 1 green on red COM port CRC Error
SW 2.3 Reserved Reserved ON 2 green on red Internal CRC Error
3 green on red Improper CCMS format
To work with a “Host
SW 2.4 Service OFF 4 green on red CCMS is absent
Machine Controller”
5 green on red Improper type of CCMS
6 green on red Download Error
5. CashCode Bezel Installation
1 2 3 4 5 6 WARNING
3. Interface Connector Pinout
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Mating Connector: DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Socket DR-12-2SC-FO (JAE); 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
PRECAUTIONS.
3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
VALIDATING HEAD AS SHOWN.
Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
9 RXD (8102003)
10 NC
11 NC Lock Washer M3, Internal Tooth, Zinc (1 pcs.)
(8203002)
12 NC
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0461
Plain Bracket
End Switch for the cassette The Part Number on the Label includes Hardware
Bezel Variant D Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0461 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01

1. Assembly FL-0461 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Housing FLH-0110 600, no lock, cassette switch, JAE
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633 Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0461_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 9 600 bps 19 200 bps ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pin-out 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0464
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.

Bracket for optional Lock for the cassette Example


FL-0464 AA0000
Two switches for the cassette and cassette Lock switch
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0464 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 66 mm Validating Head,
FLV-0310
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600 Optional bracket for the cassette Lock;
Housing FLH-0820 Two Switches for the cassette and cassette
lock Switch; JAE connector;

www.igrotechnics.ru
CashCode A Crane Co. Company
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG-FL-0464_A 03/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW#2 ON State OFF State Default Setting
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 9 600 bps 19 200 bps ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 green on red COM port CRC Error
1 2 3 4 5 6 2 green on red Internal CRC Error
3. Interface Connector Pinout
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5 green on red Improper type of CCMS
6 green on red Download Error
Terminal Circuit
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0465
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Bracket for optional Lock for the cassette Example
End Switch for the cassette and cassette Lock FL-0465 AA0000
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0465 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;

www.igrotechnics.ru CashCode A Crane Co. Company


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG-FL-0465_A 04/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Sense-A-Click failed.
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 3 red on black Cassette is full
SW 1.4 4-th Bill Enable 4-th Bill Disable ON Mechanical jam in the cassette (stacking motor can not
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 4 red on black
stack the bill)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
7 red on black Failure of magnetic sensors
8 red on black Transporting motor failure (timeout)
SW#2 ON State OFF State Default Setting
SW 2.1 Four Way One Way ON 9 red on black Speed of transporting motor is too fast
SW 2.2 Reserved Reserved ON 10 red on black Failure of Aligning motor or sensor
SW 2.3 Reserved Reserved ON 11red on black Bill pathway latch is not empty (bill is jam)
To work with a “Host Banknote jammed in the entry slot of the cassette and credit
SW 2.4 Service OFF 12 red on black
Machine Controller” were not issued
13 red on black Transport Motor overload
1 green on red COM port CRC Error
1 2 3 4 5 6 2 green on red Internal CRC Error
3. Interface Connector Pinout
Mating Connector: 3 green on red Improper CCMS format
Socket DR-12-2SC-FO (JAE); 4 green on red CCMS is absent
Contact DR-SC20-1-7000 (JAE). 5 green on red Improper type of CCMS
7 8 9 10 11 12
6 green on red Download Error
Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0466
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette
The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Bezel Variant D
Example
FL-0466 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0466 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;

www.igrotechnics.ru
Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0466_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
only. See Software Description document for exact switches and jumpers settings. 1 red on black Cassette is out of position
OFF State Wrong Sense-A-Click type or communication with
SW. #1 ON State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON
3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 9 600 bps 19 200 bps ON
13 red on black Transport Motor overload
To work with a “Host
SW 2.4 Service OFF 1 green on red COM port CRC Error
Machine Controller”
2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6
3. Interface Connector Pinout 5 green on red Improper type of CCMS
6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Terminal Circuit 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0468
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
Bracket for optional Lock for the cassette Part Number and Software Part Number.
End Switch for the cassette and cassette Lock
Example
Bezel Variant D FL-0468 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing 1000 with Lock: Part # OPT-MKFL-FLH1

OPTIONAL ACCESSORIES AND DOCUMENTS: 1. Assembly FL-0468 contents


Sensor Box Extractor: Part # OPT-HW-FT01

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-1710 12V DC, Opto Isolated, Platform A
Interface
Sense FLS-1801U Set of Basic Sense-A-Click
-A- FLS-1801
FLS-1801L sensor packs;
Click

1000 Bill; Lock Bracket; Cassette switch;


Housing FLH-3510
12pin JAE

www.igrotechnics.ru
Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm

A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG- FL-0468_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
only. See Software Description document for exact switches and jumpers settings. 1 red on black Cassette is out of position
OFF State Wrong Sense-A-Click type or communication with
SW. #1 ON State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON
3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 9 600 bps 19 200 bps ON
13 red on black Transport Motor overload
To work with a “Host
SW 2.4 Service OFF 1 green on red COM port CRC Error
Machine Controller”
2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6
3. Interface Connector Pinout 5 green on red Improper type of CCMS
6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Terminal Circuit 2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
1 +12 V
2 M.RES
3 +12 V (INTERFACE)
4 GND
5 LED +
6 NC
7 GND
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 LED -
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0469
Plain Bracket
End Switch for the cassette The Part Number on the Label includes Hardware
Part Number and Software Part Number.
Bezel Variant D
Example
ENCLOSURE: FL Bill Validator FL-0469 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01

1. Assembly FL-0469 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Housing FLH-0110 600, no lock, cassette switch, JAE
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633 Bezel FLB-5237 Bezel Variant D, Handled Bill width 70 mm
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0510_B 00411/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example 1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings. Wrong Sense-A-Click type or communication with
OFF State 2 red on black
SW. #1 ON State Default Setting Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
4 red on black
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
12 red on black
SW 2.2 Reserved Reserved ON not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector: 5. CashCode Bezel Installation
Socket DR-12-2SC-FO (JAE); WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V

www.igrotechnics.ru
8 TxD-RS
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0470
FEATURES: Fixed Width Validator Head The Part Number on the Label includes Hardware
Plain Bracket Part Number and Software Part Number.
End Switch for the cassette Example
Bezel Variant D FL-0470 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
Hardware Part Number
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE

1. Assembly FL-0470 contents


OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
600 Bill; Plain Bracket; Cassette switch;
Housing FLH-0110
12pin JAE
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Validating Bill width 66 mm Validating Head, Mega128,
FLV-0310
Head non-coated PCBs
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Bezel FLB-5217 Bezel Variant D, Handled Bill width 66 mm

www.igrotechnics.ru
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0470_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 GND PRECAUTIONS.
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0471
FEATURES: Fixed Width Validator Head
The Part Number on the Label includes Hardware
Plain Bracket Part Number and Software Part Number.
End Switch for the cassette
Example
Bezel Variant A FL-0471 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0471 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
Housing FLH-0110 600, no lock, cassette switch, JAE
Bezel Variant A,

www.igrotechnics.ru
Bezel FLB-5231
Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0471_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0472
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
UDN Customized Bracket for optional Lock for the cassette Example
End Switch for the cassette and cassette Lock FL-0472 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator Hardware Part Number
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0472 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Unit Unit Part No.: Unit Description
Sensor Box Extractor: Part # OPT-HW-FT01
600 Bill; UDN Customized Lock Bracket;
Housing FLH-0812
Cassette switch; 12pin JAE
Power
FLP-9028 24V DC, RS-232, Coated PCB, Platform B
Interface
Validating Bill width 70 mm Validating Head, Mega128,
FLV-9016
Head Coated PCBs
Sense FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs; Coated PCB
Click

www.igrotechnics.ru
CashCode A Crane Co. Company
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG- FL-0472_A 05/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors.
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12

Terminal Circuit
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V
8 TxD-RS

www.igrotechnics.ru
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0476
Plain Bracket
The Part Number on the Label includes Hardware
End Switch for the cassette Part Number and Software Part Number.
Bezel Example
FL- 0354 AA0000
ENCLOSURE: FL Bill Validator Software Part Number
User's Guide Hardware Part Number
Software description
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01
1. Assembly FL-0476 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head, Mega128,
FLV-0310 non-coated PCBs
Head
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Housing FLH-0110 600, no lock, cassette switch, JAE
A division of
Bezel, Handled Bill width 66 mm
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3 Bezel FLB-5611
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0476_C 06/09


4. Diagnostics
2. Typical DIP Switches and Jumpers Setting Count the number of flashes and compare with the diagnostic chart below:
## of flashes Malfunction
To access switches and jumpers on the CPU board pull out Validating Head, open 1 red on black Cassette is out of position
transparent cover at rear side of the Validating Head. The data in the chart is example Wrong Sense-A-Click type or communication with
2 red on black
only. See Software Description document for exact switches and jumpers settings. Sense-A-Click failed.
3 red on black Cassette is full
SW. #1 ON State OFF State Default Setting
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.1 1-st Bill Enable 1-st bill Disable ON 4 red on black
bill)
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
6 red on black Failure of optical sensors
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
10 red on black Failure of Aligning motor or sensor
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
11red on black Bill pathway latch is not empty (bill is jam)
Banknote jammed in the entry slot of the cassette and credit were
SW#2 ON State OFF State Default Setting 12 red on black
not issued
SW 2.1 Four Way One Way ON
13 red on black Transport Motor overload
SW 2.2 Reserved Reserved ON
1 green on red COM port CRC Error
SW 2.3 Reserved Reserved ON
2 green on red Internal CRC Error
To work with a “Host
SW 2.4 Service OFF 3 green on red Improper CCMS format
Machine Controller”
4 green on red CCMS is absent
5 green on red Improper type of CCMS
1 2 3 4 5 6 6 green on red Download Error
3. Interface Connector Pinout 5. CashCode Bezel Installation
Mating Connector: WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Socket DR-12-2SC-FO (JAE); DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
.
Terminal Circuit
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V

www.igrotechnics.ru
8 TxD-RS
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0477
Plain Bracket
End Switch for the cassette The Part Number on the Label includes Hardware
Bezel Part Number and Software Part Number.
Example
ENCLOSURE: FL Bill Validator FL-0477 AA0000
User's Guide Software Part Number
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01

1. Assembly FL-0477 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Housing FLH-0110 600, no lock, cassette switch, JAE
A division of
Bezel, Handled Bill width 70 mm
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
Bezel FLB-5631
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0477_C 06/09


4. Diagnostics
2. Typical DIP Switches and Jumpers Setting Count the number of flashes and compare with the diagnostic chart below:
## of flashes Malfunction
To access switches and jumpers on the CPU board pull out Validating Head, open 1 red on black Cassette is out of position
transparent cover at rear side of the Validating Head. The data in the chart is example Wrong Sense-A-Click type or communication with
2 red on black
only. See Software Description document for exact switches and jumpers settings. Sense-A-Click failed.
3 red on black Cassette is full
SW. #1 ON State OFF State Default Setting
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.1 1-st Bill Enable 1-st bill Disable ON 4 red on black
bill)
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
6 red on black Failure of optical sensors
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
10 red on black Failure of Aligning motor or sensor
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
11red on black Bill pathway latch is not empty (bill is jam)
Banknote jammed in the entry slot of the cassette and credit were
SW#2 ON State OFF State Default Setting 12 red on black
not issued
SW 2.1 Four Way One Way ON
13 red on black Transport Motor overload
SW 2.2 Reserved Reserved ON
1 green on red COM port CRC Error
SW 2.3 Reserved Reserved ON
2 green on red Internal CRC Error
To work with a “Host
SW 2.4 Service OFF 3 green on red Improper CCMS format
Machine Controller”
4 green on red CCMS is absent
5 green on red Improper type of CCMS
1 2 3 4 5 6 6 green on red Download Error
3. Interface Connector Pinout 5. CashCode Bezel Installation
Mating Connector: WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Socket DR-12-2SC-FO (JAE); DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
PRECAUTIONS.
Terminal Circuit
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V

www.igrotechnics.ru
8 TxD-RS
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
24 V DC 0.5 A 1.0 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg

FEATURES: Fixed Width Validator Head


Hardware part # FL-0479
Plain Bracket
End Switch for the cassette
The Part Number on the Label includes Hardware
Part Number and Software Part Number.
ENCLOSURE: FL Bill Validator Example
FL-0479 AA0000
User's Guide
Software description Software Part Number
MK JAE Connector: Part# OPT-MKFL-JAE Hardware Part Number

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01
1. Assembly FL-0479 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head, Mega128,
FLV-0310 non-coated PCBs
Head
Power
FLP-5710 24V DC, RS-232, Platform B
Interface
Sense FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click

www.igrotechnics.ru
Housing FLH-0110 600, no lock, cassette switch, JAE
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

2009 CashCode A Crane Co. Company PT# UG-FL-0479_B 06/09


4. Diagnostics
2. Typical DIP Switches and Jumpers Setting Count the number of flashes and compare with the diagnostic chart below:
## of flashes Malfunction
To access switches and jumpers on the CPU board pull out Validating Head, open 1 red on black Cassette is out of position
transparent cover at rear side of the Validating Head. The data in the chart is example Wrong Sense-A-Click type or communication with
2 red on black
only. See Software Description document for exact switches and jumpers settings. Sense-A-Click failed.
3 red on black Cassette is full
SW. #1 ON State OFF State Default Setting
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.1 1-st Bill Enable 1-st bill Disable ON 4 red on black
bill)
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
6 red on black Failure of optical sensors
SW 1.4 4-th Bill Enable 4-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
9 red on black Speed of transporting motor is too fast
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
10 red on black Failure of Aligning motor or sensor
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
11red on black Bill pathway latch is not empty (bill is jam)
Banknote jammed in the entry slot of the cassette and credit were
SW#2 ON State OFF State Default Setting 12 red on black
not issued
SW 2.1 Four Way One Way ON
13 red on black Transport Motor overload
SW 2.2 Reserved Reserved ON
1 green on red COM port CRC Error
SW 2.3 Reserved Reserved ON
2 green on red Internal CRC Error
To work with a “Host
SW 2.4 Service OFF 3 green on red Improper CCMS format
Machine Controller”
4 green on red CCMS is absent
5 green on red Improper type of CCMS
1 2 3 4 5 6 6 green on red Download Error
3. Interface Connector Pinout
Mating Connector:
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12

Terminal Circuit
1 GND
2 Reset-RS
3 Reserved
4 Signal Ground
5 Reserved
6 Reserved
7 +24 V

www.igrotechnics.ru
8 TxD-RS
9 RxD-RS
10 Reserved
11 Reserved
12 Reserved
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0489
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Plain Bracket
Example
End Switch for the cassette FL-0489 AA0000
Bezel Variant A
Software Part Number

ENCLOSURE: FL Bill Validator Hardware Part Number


User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0489 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1801U Set of Basic Sense-A-Click
-A- FLS-1801
FLS-1801L sensor packs;
Click
Housing FLH-0110 600, no lock, cassette switch, JAE
Bezel Variant A,

www.igrotechnics.ru
Bezel FLB-5231
Handled Bill width 70 mm
A division of
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0489_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0491
FEATURES: Fixed Width Validator Head The Part Number on the Label includes Hardware
Plain Bracket Part Number and Software Part Number.
End Switch for the cassette Example
Runway Lights CashCode Bezel FL-0491 AA0000
Software Part Number
ENCLOSURE: FL Bill Validator Hardware Part Number
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01 1. Assembly FL-0491 contents

Unit Unit Part No.: Unit Description


Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
Housing FLH-0110 600, no lock, cassette switch, JAE
CashCode Runway Lights Bezel,

www.igrotechnics.ru
Bezel FLB-9059
A division of
Handled Bill width 66 mm, Coated PCB
CashCode A Crane Co. Company
553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

2007 CashCode A Crane Co. Company PT# UG-FL-0491_A 09/07


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12
5. CashCode Bezel Installation
WARNING
1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
Terminal Circuit DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
1 +12 V PRECAUTIONS.
2 M.RES 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
3 NC VALIDATING HEAD AS SHOWN.

4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
Nylon Push Rivet, Richko SR 3055 (2 pcs.)
(8102003)

Lock Washer M3, Internal Tooth, Zinc (1 pcs.)


(8203002)
Screw M3x6, Phillips, Pan Head, Zinc (1 pcs.)
(8201000)
6. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION: A division of
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Use only current limiting CSA or UL recognized CLASS 2 Power Supply. Front Loaded Bill Validator
OPERATING TEMPERATURE: -0 to +50 degrees Celsius
TOTAL WEIGHT: WITHOUT CASSETTE: < 4.2 kg
CASSETTE WEIGHT: 1.8 kg
Hardware part # FL-0493
FEATURES: Fixed Width Validator Head
Bracket for optional Lock for the cassette
The Part Number on the Label includes Hardware
End Switch for the cassette and cassette Lock Part Number and Software Part Number.
Bezel
Example
FL-0493 AA0000
ENCLOSURE: FL Bill Validator
Software Part Number
User's Guide
Software description Hardware Part Number
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock; Part # OPT-MKFL-FLH

OPTIONAL ACCESSORIES AND DOCUMENTS:


Sensor Box Extractor: Part # OPT-HW-FT01
1. Assembly FL-0493 contents

Unit Unit Part No.: Unit Description


Validating Bill width 70 mm Validating Head,
FLV-0510
Head Mega128, non-coated PCBs
Power
FLP-2710 12V DC, RS-232, CC-EBA, Platform A
Interface
Sense
FLS-1704U Set of Basic Sense-A-Click
-A- FLS-1704
FLS-1704L sensor packs;
Click
600, Optional bracket for the cassette Lock;

www.igrotechnics.ru
Housing FLH-0810 Switch for the cassette and cassette lock;
A division of JAE connector;
2720 Steeles Avenue West, Units 2-3, Concord, ON, Canada, L4K 4S3
TEL: (905) 303-8874, 1(800)-584-2633 Bezel FLB-5031 Bezel, Handled Bill width 70 mm
FAX: (905) 303-8875, 1(800)-593-2633
Web Address: www.cashcode.com
Email: support@cashcode.com

© 2009 CashCode A Crane Co. Company PT# UG-FL-0493_B 04/09


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
Count the number of flashes and compare with the diagnostic chart below:
To access switches and jumpers on the CPU board pull out Validating Head, open ## of flashes Malfunction
transparent cover at rear side of the Validating Head. The data in the chart is example
1 red on black Cassette is out of position
only. See Software Description document for exact switches and jumpers settings.
Wrong Sense-A-Click type or communication with
SW. #1 ON State OFF State Default Setting 2 red on black
Sense-A-Click failed.
SW 1.1 1-st Bill Enable 1-st bill Disable ON 3 red on black Cassette is full
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON Mechanical jam in the cassette (stacking motor can not stack the
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON 4 red on black
bill)
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 5 red on black Failure of capacitance sensors
SW 1.5 5-th Bill Enable 5-th Bill Disable ON 6 red on black Failure of optical sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON 7 red on black Failure of magnetic sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON 8 red on black Transporting motor failure (timeout)
SW 1.8 8-th Bill Enable 8-th Bill Disable ON 9 red on black Speed of transporting motor is too fast
10 red on black Failure of Aligning motor or sensor
SW#2 ON State OFF State Default Setting 11red on black Bill pathway latch is not empty (bill is jam)
SW 2.1 Four Way One Way ON Banknote jammed in the entry slot of the cassette and credit were
SW 2.2 Reserved Reserved ON 12 red on black
not issued
SW 2.3 Reserved Reserved ON 13 red on black Transport Motor overload
To work with a “Host 1 green on red COM port CRC Error
SW 2.4 Service OFF
Machine Controller” 2 green on red Internal CRC Error
3 green on red Improper CCMS format
4 green on red CCMS is absent
1 2 3 4 5 6 5 green on red Improper type of CCMS
3. Interface Connector Pinout 6 green on red Download Error
Mating Connector:
Socket DR-12-2SC-FO (JAE); 5. CashCode Bezel Installation
WARNING
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12 1. BEFORE INSTALLING OR REMOVING BEZEL MODULE SWITCH OFF POWER SUPPLY OR
DISCONNECT POWER-INTERFACE CABLE FROM VALIDATOR HOUSING.
2. AVOID TOUCHING ELECTRICAL CONNECTORS AND CABLES WITHOUT ELECTROSTATIC
Terminal Circuit PRECAUTIONS.
1 +12 V 3. GROUND TERMINAL FROM THE BEZEL MUST BE PLACED UNDER THE SCREW AT THE
VALIDATING HEAD AS SHOWN.
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC
5. General Specifications: FL Bill Validator

CURRENCY AND INTERFACES See Software Description document


User’s Guide
ELECTRICAL SPECIFICATION:
Operating Voltage Maximum Operating Current Maximum Current
12 V DC 1.0 A 2.3 A
Front Loaded Bill Validator
Use only current limiting CSA or UL recognized CLASS 2 Power Supply.

OPERATING TEMPERATURE:
TOTAL WEIGHT:
-0 to +50 degrees Celsius
WITHOUT CASSETTE: < 4.2 kg
Hardware part # FL-0496
CASSETTE WEIGHT: 1.8 kg
The Part Number on the Label includes Hardware
FEATURES: Fixed Width Validator Head Part Number and Software Part Number.
Bracket for optional Lock for the cassette Example
FL-0496 AA0000
End Switch for the cassette and cassette Lock
Software Part Number
Hardware Part Number
ENCLOSURE: FL Bill Validator
User's Guide
Software description
MK JAE Connector: Part# OPT-MKFL-JAE
MK (M)FL Housing with Lock: Part # OPT-MKFL-FLH
1. Assembly FL-0496 contents
OPTIONAL ACCESSORIES AND DOCUMENTS:
Sensor Box Extractor: Part # OPT-HW-FT01
Unit Unit Part No.: Unit Description
Validating Bill width 66 mm Validating Head, Mega128,
FLV-9014
Head Coated PCB
Power 12V DC, RS-232, CC-EBA, Platform A,
FLP-2510
Interface Coated PCB
Sense
FLS-1706U Set of Basic Sense-A-Click
-A- FLS-1706
FLS-1706L sensor packs, Coated PCB
Click
600, Optional bracket for the cassette Lock;
Housing FLH-0810 Switch for the cassette and cassette lock;
JAE connector;

www.igrotechnics.ru CashCode Company Inc.


553 Basaltic Rd. Concord, Ontario Canada. L4K 4W8
TEL: (905) 303-8874 (800)-584-2633
FAX: (905) 303-8875 (800)-593-2633

© 2004, CashCode Co. Inc PT# UG-FL-0496_A 08/04


2. Typical DIP Switches and Jumpers Setting 4. Diagnostics
To access switches and jumpers on the CPU board pull out Validating Head, open Count the number of flashes and compare with the diagnostic chart below:
transparent cover at rear side of the Validating Head. The data in the chart is example ## of flashes Malfunction
only. See Software Description document for exact switches and jumpers settings.
SW. #1 ON State OFF State Default Setting 1 red on black Cassette is out of position
SW 1.1 1-st Bill Enable 1-st bill Disable ON Wrong Sense-A-Click type or communication with
2 red on black
Sense-A-Click failed.
SW 1.2 2-nd Bill Enable 2-nd Bill Disable ON
3 red on black Cassette is full
SW 1.3 3-rd Bill Enable 3-rd Bill Disable ON
Mechanical jam in the cassette (stacking motor can not stack the
SW 1.4 4-th Bill Enable 4-th Bill Disable ON 4 red on black
bill)
SW 1.5 5-th Bill Enable 5-th Bill Disable ON
5 red on black Failure of capacitance sensors
SW 1.6 6-th Bill Enable 6-th Bill Disable ON
6 red on black Failure of optical sensors
SW 1.7 7-th Bill Enable 7-th Bill Disable ON
7 red on black Failure of magnetic sensors
SW 1.8 8-th Bill Enable 8-th Bill Disable ON
8 red on black Transporting motor failure (timeout)
9 red on black Speed of transporting motor is too fast
SW#2 ON State OFF State Default Setting
10 red on black Failure of Aligning motor or sensor
SW 2.1 Four Way One Way ON
11red on black Bill pathway latch is not empty (bill is jam)
SW 2.2 Reserved Reserved ON
Banknote jammed in the entry slot of the cassette and credit were
SW 2.3 Reserved Reserved ON 12 red on black
not issued
To work with a “Host
SW 2.4 Service OFF 13 red on black Transport Motor overload
Machine Controller”
1 green on red COM port CRC Error
2 green on red Internal CRC Error
3 green on red Improper CCMS format
1 2 3 4 5 6 4 green on red CCMS is absent
3. Interface Connector Pinout
Mating Connector: 5 green on red Improper type of CCMS
6 green on red Download Error
Socket DR-12-2SC-FO (JAE);
Contact DR-SC20-1-7000 (JAE). 7 8 9 10 11 12

Terminal Circuit
1 +12 V
2 M.RES
3 NC
4 GND
5 NC
6 NC
7 -12 V
8 TXD

www.igrotechnics.ru
9 RXD
10 NC
11 NC
12 NC

You might also like