You are on page 1of 4
SIEMENS Surge monitor 3EXS 030 / 3EX5 050 Operating Instructions (Order-No.: 928 00031 176b bee 3EXS 030 3EXS 050 288 abe age 23% Contents B22 Contents 1 £83 Goneral 2 3&8 AC Versions 2 £6 Installation 3 3822 Maintenance 4 §E£ 4 Disposal arrester and arrester accessories 4 Size Peek ge is bo25 abak ‘Siemens Aktiengeselischaft All rights reserved © Siemens AG + 10/2003 The manufacturer of this surge arrester Siemens AG Power Transmission and Distribution Group High Voltage Division has introduced and applies a quality system in accordance with DIN ISO 9001 / EN 29 001 ‘Quality systems: Model for quality assurance This system was first demonstrated in 1989 to the DQS (German Association for the Cerification of Quality Systems). ‘The electrical testing laboratories and the materials technology laboratories of the manufacturer have been certified since 1992 by the German Accreditation Body in accordance with DIN EN 45 004 I you require further copies of the operating instructions, please order them from the appropriate Siemens office, indicating the tite and order number shown on the title page. Published by: Siemens AG PTOHA D-13623 Bertin ‘Subject to change. OF note | ‘The equipment covered by these instructions should be installed and serviced only by ‘competent personnel familiar with good safety practices. This instruction is written for such personnel and is not intended as a substitute for adequate training an experience in safe procedures. This information is intended for the corret instalation of ths product. Siemens has no control aver the consition ofthe network, which can be greatly affeces by the installation of @ product. Itis the responsibilty ofthe user to chose the appropriate method of installation. Under no circumstance is Siamane lable for any director incract damage caused by the use or misuse ofthis product General This product is a robustly constructed instrument suitable for installation in the earth connection of a surge arrester which must be isolated from earth for the counter to operate correctly To prevent damage the product must not be subjected to rough handling or mechanical shocks either during or after installation, Model 3EXS 030 is suitable for use with single arresters or three phase sets. > Model 3EXS 050 is suitable only for use with a single arrester. The counter is sealed in a weatherproof housing with a serial number on the back of the housing, AC Versions A voltage-free contact is available to allow connection to a remote counter or indicator. The contacts are related 0,5A 240V AC maximum. 2 © Siemens AG + 10/2003 Warning Before any work starts: > switch off and isolate secure against reclosing verify that equipment is dead earth and short circuit the equipment cover or fence off nearby live parts vvvvy Death, severe injury and considerable damage to property and environmental damage may result if the safety instructions are not followed, > Confirm that these safety measures have been carried out. Line tormination M12 nickel plated brass fited wih 2-ickel plated brass locknuts Moulded resin insulator Hormetically sealed glass display panel (Ground termination M12 rickel plated brass fitted with 2-rckel plated brass locknuts M12» 35 galvanised sel set serew with full nut and spring washer ‘Surge Counter leakage current dsplay (only 3EX5 050) 9.1 Surge counter 3EXS 030 / Surge monitor 3EXS 050 ISF note ‘The product should ideally be mounted at eye-level on a horizontal surface such as cross-channel or angle suppor. Operation is not impaired at angles up to 60" total clearance of atleast 30mm must be allowed between the live terminal ofthe surge counter and any earthed abject, | © Siemens AG - 10/2003 3 Connections to the surge counter may be made with either cable or bare conductor with suitable ter- rmination to the M12 line and earth studs, which are nickel plated brass. Care should be taken when tightening the connections to avoid overstressing the terminals and the use of two spanners is rec- ‘ommended. Should bare conductor be used this also be isolated from any earthed structure by 30mm. The max. torque with tightening the nuts/mothers may not are exceeded: > M12: 40Nm Maintenance Under normal operating conditions this product does not require any maintenance, except for periodic cleaning of the glass and the line bushing. The tightness of the connections should be checked at the same time. No electrical tests should be undertaken to the counter without the previous agreement of the manu- facturer. Disposal arrester and arrester accessories Surge arresters and the accessories are an environmentally compatible product. In disposal, priority must be given to reuse of the materials. Environmentally acceptable disposal of the surge arresters and the accessories is possible in line with current legistation The following materials have been used to make up the device: Steel, copper, aluminium, PTFE, cast resin or cast-resin-impregnated fabric, glass-fibre-reinforced plastics, polyurethane, rubbers for seal- ing, ceramics, electronic components and silicon rubber (VMQ), ceramics (porcelain, metal oxide) The device can be recycled as mixed scrap, or, fit is dismantled as far as possible, in a more envi- ronmentally acceptable way as sorted scrap with a mixed-scrap residual portion. The arrester resistors cf metal oxide (MO) should be disposed of as industrial waste similar to domestic garbage (not as building rubbie). In as-supplied-by-Siemens state, the device incorporates no hazardous substances in the sense of the pertinent regulations in Germany. If the device is to be operated outside Germany, the locally applica- ble laws and regulations must be followed. Local customer support offices willbe able to answer any questions conceming disposal. a © Siemens AG + 10/2003

You might also like