You are on page 1of 18
VEVOR TOUGH TOOLS, HALF PRICE Technical Support and E+Warranty Certificate www.vevor.com/support Pipe Water Leak Detector MODEL:T8-A10W ‘We contnus to be commitied to provide you tools with competiive price, "Save Hal, "Half Price" or any other similar expressions used by us only represerts an ‘estimate of savings you might benefit from buying certain tools with us compared to the major top brangs and doses not nacessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are ‘actuslly saving haf in comparison with the top major brands, Catalog |. Need help? contact us! -------------+++2+2s+eeereceeeseesee 1 IL. Product introduction «++ttttteseeser essen eeeaes 2 INL, Product features:+ersesssenreerssenreersecseseeearseeereareaey 3 IV, Technical parameter and components «t+teereseeeeare 3 V.Operation interface and key operation instructions «+5 VI. Product installation instructionse++++++ssesseerseenreerenry 8 VIL. Analysis and elimination of common failures --++++++42 VII. APP download and network configurations::++1110+ 13 IX. Transportation and Storage -++reeereeeeeeeeeeeeeeee eee 15 VEVOR’ Pipe Water TOUGH TOOLS, HALF PRICE Leak Detector MODEL:T8-A10W NEED HELP? CONTACT US! Have product questions? Need technical support? Please feel free to contact us: Technical Support and E-Warranty Certificate www.vevor.com/support This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product, Warning-To reduce the risk of injury, user must read instructions manual carefully, This device complies with Part 15 of the FCC Rules. Operation is 6| @ ‘subject to the following two conditions:(1)This device may not cause harmtul interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. This product is subject to the provision of European Directive aid 2012/19/EC. The symbol showing a wheelie bin crossed through a indicates thal the product requires separate refuse collection in the European Union. This applies to the product and all accessories marked with this symbol. Products marked as such may not be discarded with normal domestic waste, but must be taken to a collection point for recycling electrical and electronic devices PRODUCT INTRODUCTION T8-A10W series is a new Al intelligent water leakage protection system based on the principle of ultrasonic time difference for flow monitoring and multi-mode water leakage protection scheme, which can accurately judge the household water situation to ensure the safety of household water.The water leakage protector can be equipped with built-in WIFI module. Users can remotely control the device and know the household water consumption situation through the APP, which is convenient for users to manage abnormal household water consumption and realtime control of the device. This product is suitable for families, hotels, apartments and other places, installed in the front end of the water pipe (after the water meter), the product needs to be connected to the power or battery before use. The medium of this product is ellowed through water, not allowed through used in other media except water supply system, such as alcohol, oil, etc. PRODUCT FEATURE The principle of ultrasonic time difference method is adopted, the measuring parts have no moving parts, the prossure loss is small, the monitoring accuracy is high, and the service life is long. According to the different household water wading equipment, there are six modes, including user mode and professional mode, to meet the different water ‘consumption conditions of users and reduce the probability of false alarm and missing alarm. Dual circuit design, standard power adapter, built-in rechargeable bthium battery, to avoid the loss of water caused by power failure or power supply failure. High range ratio, working water monitoring range: 2.0L-4000 L/H, can real-time monitoring household leakage, leakage pipe explosion and other abnormal conditions, to ensure the safety of houschald water, Built-in large capacity storage Al chip, the mode setting has a memory function, TECHNICAL PARAMETER AND COMPONENTS Product name: Pipe Water Leak Detector Product type: T8-A10W. configuration Al water leakage protector+APP(WIFI)-Standard Applicable — water temperture:1-50'C Applicable water pressure:0.1-0.75MPa, Product size:174x78x109mm External power input:100-240V SO/60HZ__output:6V/1A Battery: Rechargeable lithium battery 3.7V Measuring range : 2.0-4000L/H(This product is not measuring equipment, the data and information provided are for reference only) Component drawing: Al intelligent water leakage protector Protectnprotect key Scroll key Valve control key Water outlet \ Power adaptor (Please strictly follow the outgoing label to connect the power supply and battery. Reverse connection or wrong connection may damage the equipment.) Mode usage: (Please set the appropriate mode according to the actual situation after installation) Mode applicable | Factory Applicable Scene scenarios default Is recommended for Mode 1 a family of two or a single apartment Suitable for Is recommended for centralized General families of 3-4 water supply Mode 2 mode people or hotel users in apartments higherise Is recommended for communities Mode 3 families or villas of 5-6 people Is recommended for | Suitable for Professional el Mode 4 | thour/1m* a family of two ora users who have mode single apartment large water Is recommended for purification 4.5nouri1.5. | families of 34 equipment such Mode 5 m people or hotel as booster apartments pump.central stage, water Is rocommended for purifier, and central water softener Mode 6 | 2hour/2m* | families or villas of 5-6 people If the user needs abnormal water use: for a long time (for example, about 1 hour) or a large amount of water (for example, Removal more than 1 ton), the "Fortification mode” can be adjusted to Mode —_| “dismount mode" to avoid the protection of the prefilter to shut off the water, and then adjust the "Fortification mode" after the end of the abnormal water use. When the water leakage protector recognizes the occurrence of leakage, buzzer buzzes and displays "Leakage Warning’. If the user does not deal with i time, the buzzer buzzes and displays "Leakage" after 3 minutes, and the protection water valve is closed_After the alarm occurs, the screen lights up for 15 seconds every hour while the buzzer sounds. The user can switch the mode to“ Unprotect mode” by long pressing the "Protecl/ Unprotect" key, thus releasing the alarm state. OPERATION INTERFACE AND KEY OPERATION INSTRUCTIONS. Query parameter: When the screen is lit touch the “Query” key can view the parameters of the water leakage protector: Ih the “Unprotect Mode”, check the flowrate, water temperature, total water consumption and fault. Ih ‘Protect mode” 1, 2, and 3, check flowrate, water temperature, total water consumption, minimum warming flowrate, and fault, lh Protect mode” 4, 5, and 6, check flowrate, water temperature, total water consumption, waming time, warning water consumption, minimum warning flowrate, and fault. OpeniClose protection water valve : When the screen is lit, long press the “Open/Close valve" key to open or close the protection water valve.after the valve is triggered. Check the clock: When the screen is It, short press the “Open/Close valve” key to view the current clock. Switch between protected mode and unprotected mode : When the screen is lit . long press the "Protect/Unprotect " key to switch “Protected mode” and “Unprotect mode” . Note: The water leakage alarm will be cleared when the “Protect mode” is switched to the “Unprotected made” . When the protection water valve is closed, the protection water valve will open automatically when the “Unprotect mode” is switched tothe “Protected mode”, Set parameters: When the screen is fit ong press the “Setting” key to enter the parameter setting mode. Then short press the " Setting " key to enter the following function parameter Settings: Inthe “Unprotect Mode” , “Clock Hour” - jock Minute” . In “Protect mode” 1, 2, and 3, ” Protection Mode” -” Minimum Warming Flowrate” - “Clock Hour” - “Clock Minute” . In “Protect mode” 4, 5, and 6, ” Protection Mode” - “Warning Time” — “ Warning Water Consumption” - ” Minimum Warning Flowrate” - “Clock Hour” = “Clock Minute” . Long press " Setting " key or after setting "Clock minutes”, tap "Setting " key to save the setting parameters and exit the parameter setting mode.Tap the "Protect/Unprotect " key or do not perform any operation within 90 seconds. The Settings are not saved and exit the parameter setting mode. Protection Mode Setting: Water leakage protection mode 1 to mode 6 can be set.Tap the "Query” key mode to add 1:Tap “Open/Close valve” key mode minus 1. Warning Time Setting: You can set the continuous water use alarm duration from mode 4 to mode 6 within the range of 4 to 3 hours. If the continuous water use exceeds the duration, -6- leakage warning will be prompted.Tap the "Query * key to increase 0.1 hours to the setting time;Tap the “Open/Close valve” key to reduce the setting time by 0.1 hours. Warning Water Consumption Setting: The warning continuous water consumption of mode 4~ mode 6 can be set within the range of 0.1~5.0 tons. When the continuous water consumption will be prompted, Tap the "Query " key to exceeds this value, the leakage wari Increase water consumption by 0,1 m3;Tap the “Open/Close valve” key to reduce the water consumption by 0.1 m3. Minimum Warning Flowrate Setting: You can set the minimum warning flowrate of mode 1 to mode 6 in the range of 1.0 to 20.0 Lih. Only when the water flowrate is greater than this set value, the leakage protector will accumulate the water duration and water consumption and give a leakage warning according to the set "Warning Time” and "Warning Water Consumption".Tap the "Query" to increase the flowrate by 0.5 L/h;Tap the “OpeniClose valve” key to reduce the flowrate by 0.5 L/h, Clock Hour Setting: You can set the hour of the current clock by tapping the "Query "key to increase the clock by 1 hour-Tap the “Open/Close valve” key to reduce the clock by 1 hour, Clock Minute Setting: You can set the minute of the current clock, Tap the "Query * key to increase the clock by 1 minute.Tap the “Open/Close valve” key to reduce the clock by 1 minute. Water inlet direction switch: Press and hold the two keys on the right("Query"key and’Open/Close valve’key) at the same time for 3 seconds to enter the water inlet direction setting stale, the animation shows the water flow direction;Press and hold the two keys on the left ("Protect/Unprotect" and "Setting"key) at the same time for 3 seconds to change the water flow direction, Press and hold the two keys on the right at the same time again for 3 seconds or do no operation for 15 seconds to exit the setting state. -7- Product water inlet instructions: The insert end is the water inlet Matters needing attention 1. After the machine is powered on, check whether the protection water valve is ‘opened once. If itis closed, open the valve. 2. When the water leakage protector detects that the battery power is low, the battery icon blinks, the buzzer buzzes, and “E0” is displayed when the fault code is queried. The screen lights up for 15 seconds every hour while the buzzer beeps;If no charge is detected after 48 hours, olose the protective water valve and remind the user to charge 3. The operation interval of the Open/Close valve key in the APP is at least 60 seconds. 4, To prevent the protection water valve from being stuck for a long time, the water valve is switched on and off once every 15 days in the early moming. E0 _| Power failure E3 | Overrange failure Et Empty pipe failure E4 _| Water temperature failure E2 | Water backflow failure | ES | Hardwere failure PRODUCT INSTALLATION INSTRUCTIONS 1. Installation method One. Horizontal installation Building water intake pipe IF the pipe is installed horizontally, you are advised to install the pipe in the U shape. In this case, the Al water leakage protector section in the lower part of the tube can remain full. B+ Two. Vertical installation Building water intake pipe When installed vertically, as shown in the figure above, the water flow direction at the Al water leakage protector is water at the lower end and water at the upper end. In this case, when water flows through, bubbles can be avoided from gathering in the Al water leakage protector measuring pipe. The compromised installation mode (horizontal) is limited by the objective conditions of the site. If it is really difficult to implement the recommended horizontal installation conditions, the installation mode should be at least as shown in the following figure, <{- Building water intake pipe In the figure, the pipe segment in front of the Al water leakage protector can be parallel to the body of the water leakage protector (compared to the recommended method, the right Angle bending structure is eliminated), but the pipe at the back end of the Al water leakage protector must be laid out as shown in the figure to avoid the accumulation of bubbles in the pipe, 2. Precautions before installation (1) Before installing the Al water leakage protector, the pipeline must be thoroughly dleaned to avoid debris damage to the Al water leakage protector: (2) Al water leakage protector is a relatively valuable and precise product. It must be picked up and put down carefully. It is forbidden to directly pull the sensor line; sd to be near high temperature heat source (such as electric Itis stricly prohi welding, to prevent battery explosion injury and damage to the product); (3) Awater leakage protector installation position should pay special attention to avoid Al water leakage protector installed at the upper end of the pipeline (there will be bubbles in the pipe section), avoid installation near the elbow (will produce vortex flow, should be far away from the pump and other equipment (will cause pulse flow): (4) The connecting pipes at the upstream and downstream of Al water leakage protector should be consistent with the caliber of the water meter Reduce diameter: (8) The direction marked on the body of Al water leakage protector is the direction of water flow; Shall not be inverted: (6) Itis recommended that the front end of the water leakage protector be equipped with a filter of the corresponding caliber; The corresponding caliber valve is installed before the product and it can be separated from the product for the convenience of future maintenance and repair. 3. Precautions before installation (1) When the product is installed vertically, it must be installed on the straight pipe with the water flowing upward, because the pipe with the water flowing downward will be affected by the gravity of earth, which will cause the phenomenon that the water in the pipeline cannot be filled, which will lead to inaccurate monitoring of Al water leakage protector or even no monitoring (as shown in Figure C). -10- 8. x rea] VW Ud u (Picture C) (2) When the Al water leakage protector is installed at the "U" shaped pipe, please install the Al water leakage protector at the lowest place, because the pipe may gather air at a high place, resulting in inaccurate or non-monitoring of the Al water leakage protector (as shown in Figure D). v x l J 4! J (Picture D) (3) When the Al water leakage protector is installed at the bend, it must be ensured that the distance between the front straight pipe is 25 times of pipe diameter and the back straight pipe is 23 times of pipe diameter, otherwise it may cause inaccurate monitoring of the Al water leakage protector (as shown in Figure E). =n. Lod bod (Picture E) (4) When installing valves or other objects in front of the Al water leakage protector, it must be ensured that there is a distance of 25 times the diameter between the Al water leakage protector and the object, otherwise it may cause inaccurate or non-monitoring of the All water leakage protector; (as shown in Figure F) (Picture F) ANALYSIS AND ELIMINATION OF COMMON FAILURES Failure type Feilure reason Method Power failure Battery undervoltage or Poor connection Check the connection plug and replace the battery ‘There is no water in the Empty pipe Fill the tube section with water and pipe section or water does failure remove ait bubbles hot fill the pipe section Water The inlet end and outlet Follow the marked water flow backflow end of the pipe section are direction failure inverted -12- Overrange The current instantaneous | Reduce the flow rate or replace the failure trafficis too high meter for the corresponding range Contact the onufacturer's technical EE failure Hardware failure personnel Contact the enufacturer's Sensor failure | Ultrasonic sensor failure technical personnel 1 Check whether the home WIFI is normal APP offline WIFI signal loss 2. Power on the device after unplugging the device. 3. Configure the network again APP DOWNLOAD AND NETWORK CONFIGURATION Al Wator Protector APP(hereinattor referred to as APP) is an auxiliary application of Water Wise Shield, which can help supervise and control Al water protector, and enjoy more functional experience and all-round security protection brought by Al water protector, 4, Connect the water leakage protector A to the power adaptor, 2, APP download: Android users: Please use the browser to scan code download: For Apple usors: soarch "Al Water protector” in APP store or scan the QR code below with wechat scan function, -13- 3. Tum on WIFI on the phone to ensure that the signal is stable and connected 4, Open the APP, register the APP and log in according to the user's situation; 5, After the screen is lit up, long touch the “Query” key and the “Protect/Unprotect” key at the same time, When the WIFI icon on the screen jumps, the device is equipped with network, Android phone: 1) AP Network Distribution: On the "My Device" interface, click "+", select "AP network Distribution” to enter the "Add Device" interface, click "Add Device distribution” to enter the "Bind Device" interface, enter the WIFI password, click "Configure the device to access the Internet, the prompt box" Please manually connect the SSID of the module! To access the WLAN Settings screen, select bsk_softap network from the list, and return to the APP application. After the network is configured successfully, device information is displayed on the My Devices screon. 2) SmartLink Network Configuration: On the My Devices screen, tap + and select ‘smartLink Network Configuration. On the Bind Device screen, enter the WIFI password, and tap Configure the Device to access the Intemet. After the network configuration is successful, the My Devices screen displays the device information, IPhone 1) AP Network allocation: On the "My Devices" screen, tap "+" to enter the "Add Device” screen, tap "AP Network allocation” to enter the "Bind Device” screen, and -14- enter the Wi-Fi password. Click "Next", and the prompt "Please connect Wi-Fi to the device AP SSID:bsk_softap, and then retum to APP" appears. Manually enter the WLAN Settings, connect the network to "bsk_softap", and return to the APP application. ‘After the network configuration is successful, device information will be displayed on the "My Devices" interface, 2) SmartLink Network Configuration: On the My Devices page, tap + to switch to the Add Device page, tap Smartlink Network Configuration to switch to the Bind Device page, enter the WieFi password, and tap Next. After the network configuration is successful, device information is displayed on the My Devices page. Please go to "Product Description” in the "My page” of the APP to lear about the operation and functions of the APP. Remarks Please make sure that the WiFi of the mobile phone is connected and the signal is good. It will take 90 seconds to complete the network configuration. TRANSPORTATION AND STORAGE 1. Handle the instrument carefully during transportation to avoid severe impact. 2. The storage environment temperature (1-50)°C, relative humidity less than 80%, protect against strong electromagnetic field and direct sunlight. 3, The products stored in the code should be at least 30cm away from the ground, at least 1m away from the four walls, and at least 2m away from the heating equipment, 4, Keep the warehouse dry, free of corrosive goods, gas and dangerous goods. -15= VEVOR’ TOUGH TOOLS, HALF PRICE Technical Support and E-Warranty Certificate www.vevor.com/support

You might also like