VEVOR
TOUGH TOOLS, HALF PRICE
Technical Support and E+Warranty Certificate www.vevor.com/support
Pipe Water Leak Detector
MODEL:T8-A10W
‘We contnus to be commitied to provide you tools with competiive price,
"Save Hal, "Half Price" or any other similar expressions used by us only represerts an
‘estimate of savings you might benefit from buying certain tools with us compared to the major
top brangs and doses not nacessarily mean to cover all categories of tools offered by us. You
are kindly reminded to verify carefully when you are placing an order with us if you are
‘actuslly saving haf in comparison with the top major brands,Catalog
|. Need help? contact us! -------------+++2+2s+eeereceeeseesee 1
IL. Product introduction «++ttttteseeser essen eeeaes 2
INL, Product features:+ersesssenreerssenreersecseseeearseeereareaey 3
IV, Technical parameter and components «t+teereseeeeare 3
V.Operation interface and key operation instructions «+5
VI. Product installation instructionse++++++ssesseerseenreerenry 8
VIL. Analysis and elimination of common failures --++++++42
VII. APP download and network configurations::++1110+ 13
IX. Transportation and Storage -++reeereeeeeeeeeeeeeeee eee 15VEVOR’ Pipe Water
TOUGH TOOLS, HALF PRICE Leak Detector
MODEL:T8-A10W
NEED HELP? CONTACT US!
Have product questions? Need technical support? Please feel free to
contact us: Technical Support and E-Warranty Certificate
www.vevor.com/support
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our
user manual. The appearance of the product shall be subject to the
product you received. Please forgive us that we won't inform you again if
there are any technology or software updates on our product,Warning-To reduce the risk of injury, user must read instructions
manual carefully,
This device complies with Part 15 of the FCC Rules. Operation is
6| @
‘subject to the following two conditions:(1)This device may not cause
harmtul interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
This product is subject to the provision of European Directive
aid 2012/19/EC. The symbol showing a wheelie bin crossed through
a
indicates thal the product requires separate refuse collection in the
European Union. This applies to the product and all accessories
marked with this symbol. Products marked as such may not be
discarded with normal domestic waste, but must be taken to a
collection point for recycling electrical and electronic devices
PRODUCT INTRODUCTION
T8-A10W series is a new Al intelligent water leakage protection system based on
the principle of ultrasonic time difference for flow monitoring and multi-mode water
leakage protection scheme, which can accurately judge the household water
situation to ensure the safety of household water.The water leakage protector can
be equipped with built-in WIFI module. Users can remotely control the device and
know the household water consumption situation through the APP, which is
convenient for users to manage abnormal household water consumption and
realtime control of the device.
This product is suitable for families, hotels, apartments and other places, installed
in the front end of the water pipe (after the water meter), the product needs to be
connected to the power or battery before use.
The medium of this product is ellowed through water, not allowed through used in
other media except water supply system, such as alcohol, oil, etc.PRODUCT FEATURE
The principle of ultrasonic time difference method is adopted, the measuring parts
have no moving parts, the prossure loss is small, the monitoring accuracy is high,
and the service life is long.
According to the different household water wading equipment, there are six modes,
including user mode and professional mode, to meet the different water
‘consumption conditions of users and reduce the probability of false alarm and
missing alarm.
Dual circuit design, standard power adapter, built-in rechargeable bthium battery,
to avoid the loss of water caused by power failure or power supply failure.
High range ratio, working water monitoring range: 2.0L-4000 L/H, can real-time
monitoring household leakage, leakage pipe explosion and other abnormal
conditions, to ensure the safety of houschald water,
Built-in large capacity storage Al chip, the mode setting has a memory function,
TECHNICAL PARAMETER AND COMPONENTS
Product name: Pipe Water Leak Detector
Product type: T8-A10W.
configuration
Al water leakage protector+APP(WIFI)-Standard
Applicable — water
temperture:1-50'C
Applicable water pressure:0.1-0.75MPa,
Product size:174x78x109mm
External power input:100-240V SO/60HZ__output:6V/1A
Battery: Rechargeable lithium battery 3.7V
Measuring range : 2.0-4000L/H(This product is not measuring equipment,
the data and information provided are for reference only)Component drawing:
Al intelligent water leakage protector Protectnprotect key
Scroll key
Valve control key
Water outlet
\ Power adaptor
(Please strictly follow the outgoing label to connect the power supply and battery.
Reverse connection or wrong connection may damage the equipment.)
Mode usage: (Please set the appropriate mode according to the actual situation
after installation)
Mode applicable | Factory
Applicable Scene
scenarios default
Is recommended for
Mode 1 a family of two or a
single apartment Suitable for
Is recommended for centralized
General families of 3-4 water supply
Mode 2
mode people or hotel users in
apartments higherise
Is recommended for communities
Mode 3 families or villas of
5-6 people
Is recommended for | Suitable for
Professional
el Mode 4 | thour/1m* a family of two ora users who have
mode
single apartment large waterIs recommended for purification
4.5nouri1.5. | families of 34 equipment such
Mode 5
m people or hotel as booster
apartments pump.central
stage, water
Is rocommended for
purifier, and
central water
softener
Mode 6 | 2hour/2m* | families or villas of
5-6 people
If the user needs abnormal water use: for a long time (for
example, about 1 hour) or a large amount of water (for example,
Removal more than 1 ton), the "Fortification mode” can be adjusted to
Mode —_| “dismount mode" to avoid the protection of the prefilter to shut off
the water, and then adjust the "Fortification mode" after the end
of the abnormal water use.
When the water leakage protector recognizes the occurrence of leakage,
buzzer buzzes and displays "Leakage Warning’. If the user does not deal with i
time, the buzzer buzzes and displays "Leakage" after 3 minutes, and the
protection water valve is closed_After the alarm occurs, the screen lights up for 15
seconds every hour while the buzzer sounds.
The user can switch the mode to“ Unprotect mode” by long pressing the
"Protecl/ Unprotect" key, thus releasing the alarm state.
OPERATION INTERFACE AND KEY OPERATION INSTRUCTIONS.
Query parameter:
When the screen is lit touch the “Query” key can view the parameters of the water
leakage protector:
Ih the “Unprotect Mode”, check the flowrate, water temperature, total water
consumption and fault.
Ih ‘Protect mode” 1, 2, and 3, check flowrate, water temperature, total water
consumption, minimum warming flowrate, and fault,
lh Protect mode” 4, 5, and 6, check flowrate, water temperature, total water
consumption, waming time, warning water consumption, minimum warning
flowrate, and fault.OpeniClose protection water valve :
When the screen is lit, long press the “Open/Close valve" key to open or close the
protection water valve.after the valve is triggered.
Check the clock:
When the screen is It, short press the “Open/Close valve” key to view the current
clock.
Switch between protected mode and unprotected mode :
When the screen is lit . long press the "Protect/Unprotect " key to switch
“Protected mode” and “Unprotect mode” .
Note:
The water leakage alarm will be cleared when the “Protect mode” is switched to
the “Unprotected made” .
When the protection water valve is closed, the protection water valve will open
automatically when the “Unprotect mode” is switched tothe “Protected mode”,
Set parameters:
When the screen is fit ong press the “Setting” key to enter the parameter
setting mode. Then short press the " Setting " key to enter the following function
parameter Settings:
Inthe “Unprotect Mode” , “Clock Hour” - jock Minute” .
In “Protect mode” 1, 2, and 3, ” Protection Mode” -” Minimum Warming
Flowrate” - “Clock Hour” - “Clock Minute” .
In “Protect mode” 4, 5, and 6, ” Protection Mode” - “Warning Time” —
“ Warning Water Consumption” - ” Minimum Warning Flowrate” - “Clock Hour”
= “Clock Minute” .
Long press " Setting " key or after setting "Clock minutes”, tap "Setting " key to
save the setting parameters and exit the parameter setting mode.Tap the
"Protect/Unprotect " key or do not perform any operation within 90 seconds. The
Settings are not saved and exit the parameter setting mode.
Protection Mode Setting:
Water leakage protection mode 1 to mode 6 can be set.Tap the "Query” key mode
to add 1:Tap “Open/Close valve” key mode minus 1.
Warning Time Setting:
You can set the continuous water use alarm duration from mode 4 to mode 6
within the range of 4 to 3 hours. If the continuous water use exceeds the duration,
-6-leakage warning will be prompted.Tap the "Query * key to increase 0.1 hours to the
setting time;Tap the “Open/Close valve” key to reduce the setting time by 0.1
hours.
Warning Water Consumption Setting:
The warning continuous water consumption of mode 4~ mode 6 can be set
within the range of 0.1~5.0 tons. When the continuous water consumption
will be prompted, Tap the "Query " key to
exceeds this value, the leakage wari
Increase water consumption by 0,1 m3;Tap the “Open/Close valve” key to
reduce the water consumption by 0.1 m3.
Minimum Warning Flowrate Setting:
You can set the minimum warning flowrate of mode 1 to mode 6 in the range
of 1.0 to 20.0 Lih. Only when the water flowrate is greater than this set value, the
leakage protector will accumulate the water duration and water consumption and
give a leakage warning according to the set "Warning Time” and "Warning Water
Consumption".Tap the "Query" to increase the flowrate by 0.5 L/h;Tap the
“OpeniClose valve” key to reduce the flowrate by 0.5 L/h,
Clock Hour Setting:
You can set the hour of the current clock by tapping the "Query "key to
increase the clock by 1 hour-Tap the “Open/Close valve” key to reduce the clock
by 1 hour,
Clock Minute Setting:
You can set the minute of the current clock, Tap the "Query * key to increase
the clock by 1 minute.Tap the “Open/Close valve” key to reduce the clock by 1
minute.
Water inlet direction switch:
Press and hold the two keys on the right("Query"key and’Open/Close
valve’key) at the same time for 3 seconds to enter the water inlet direction setting
stale, the animation shows the water flow direction;Press and hold the two keys on
the left ("Protect/Unprotect" and "Setting"key) at the same time for 3 seconds to
change the water flow direction, Press and hold the two keys on the right at the
same time again for 3 seconds or do no operation for 15 seconds to exit the setting
state.
-7-Product water inlet instructions:
The insert end is the water inlet
Matters needing attention
1. After the machine is powered on, check whether the protection water valve is
‘opened once. If itis closed, open the valve.
2. When the water leakage protector detects that the battery power is low, the
battery icon blinks, the buzzer buzzes, and “E0” is displayed when the fault code
is queried. The screen lights up for 15 seconds every hour while the buzzer
beeps;If no charge is detected after 48 hours, olose the protective water valve and
remind the user to charge
3. The operation interval of the Open/Close valve key in the APP is at least 60
seconds.
4, To prevent the protection water valve from being stuck for a long time, the water
valve is switched on and off once every 15 days in the early moming.
E0 _| Power failure E3 | Overrange failure
Et Empty pipe failure E4 _| Water temperature failure
E2 | Water backflow failure | ES | Hardwere failure
PRODUCT INSTALLATION INSTRUCTIONS
1. Installation method
One. Horizontal installation
Building water intake pipe
IF the pipe is installed horizontally, you are advised to install the pipe in
the U shape. In this case, the Al water leakage protector section in the
lower part of the tube can remain full.
B+Two. Vertical installation
Building water intake pipe
When installed vertically, as shown in the figure above, the water flow direction at
the Al water leakage protector is water at the lower end and water at the upper end.
In this case, when water flows through, bubbles can be avoided from gathering in
the Al water leakage protector measuring pipe.
The compromised installation mode (horizontal) is limited by the objective
conditions of the site. If it is really difficult to implement the recommended
horizontal installation conditions, the installation mode should be at least as shown
in the following figure,
<{- Building water intake pipe
In the figure, the pipe segment in front of the Al water leakage protector can beparallel to the body of the water leakage protector (compared to the recommended
method, the right Angle bending structure is eliminated), but the pipe at the back
end of the Al water leakage protector must
be laid out as shown in the figure to avoid the accumulation of bubbles in
the pipe,
2. Precautions before installation
(1) Before installing the Al water leakage protector, the pipeline must be thoroughly
dleaned to avoid debris damage to the Al water leakage protector:
(2) Al water leakage protector is a relatively valuable and precise product. It must
be picked up and put down carefully. It is forbidden to directly pull the sensor line;
sd to be near high temperature heat source (such as electric
Itis stricly prohi
welding, to prevent battery explosion injury and damage to the product);
(3) Awater leakage protector installation position should pay special attention to
avoid Al water leakage protector installed at the upper end of the pipeline (there
will be bubbles in the pipe section), avoid installation near the elbow (will produce
vortex flow, should be far away from the pump and other equipment (will cause
pulse flow):
(4) The connecting pipes at the upstream and downstream of Al water leakage
protector should be consistent with the caliber of the water meter
Reduce diameter:
(8) The direction marked on the body of Al water leakage protector is the direction
of water flow; Shall not be inverted:
(6) Itis recommended that the front end of the water leakage protector be
equipped with a filter of the corresponding caliber; The corresponding caliber valve
is installed before the product and it can be separated from the product for the
convenience of future maintenance and repair.
3. Precautions before installation
(1) When the product is installed vertically, it must be installed on the straight pipe
with the water flowing upward, because the pipe with the water flowing downward
will be affected by the gravity of earth, which will cause the phenomenon that the
water in the pipeline cannot be filled, which will lead to inaccurate monitoring of Al
water leakage protector or even no monitoring (as shown in Figure C).
-10-8. x rea] VW
Ud u
(Picture C)
(2) When the Al water leakage protector is installed at the "U" shaped pipe,
please install the Al water leakage protector at the lowest place, because the
pipe may gather air at a high place, resulting in inaccurate or non-monitoring of
the Al water leakage protector (as shown in Figure D).
v x
l J 4! J
(Picture D)
(3) When the Al water leakage protector is installed at the bend, it must be
ensured that the distance between the front straight pipe is 25 times of pipe
diameter and the back straight pipe is 23 times of pipe diameter, otherwise it may
cause inaccurate monitoring of the Al water leakage protector (as shown in
Figure E).
=n.Lod bod
(Picture E)
(4) When installing valves or other objects in front of the Al water leakage
protector, it must be ensured that there is a distance of 25 times the diameter
between the Al water leakage protector and the object, otherwise it may cause
inaccurate or non-monitoring of the All water leakage protector; (as shown in
Figure F)
(Picture F)
ANALYSIS AND ELIMINATION OF COMMON FAILURES
Failure type
Feilure reason
Method
Power failure
Battery undervoltage or
Poor connection
Check the connection plug
and replace the battery
‘There is no water in the
Empty pipe Fill the tube section with water and
pipe section or water does
failure remove ait bubbles
hot fill the pipe section
Water The inlet end and outlet
Follow the marked water flow
backflow end of the pipe section are
direction
failure inverted
-12-Overrange The current instantaneous | Reduce the flow rate or replace the
failure trafficis too high meter for the corresponding range
Contact the onufacturer's technical
EE failure Hardware failure
personnel
Contact the enufacturer's
Sensor failure | Ultrasonic sensor failure
technical personnel
1 Check whether the home WIFI is
normal
APP offline WIFI signal loss 2. Power on the device after
unplugging the device.
3. Configure the network again
APP DOWNLOAD AND NETWORK CONFIGURATION
Al Wator Protector APP(hereinattor referred to as APP) is an auxiliary application
of Water Wise Shield, which can help supervise and control Al water protector, and
enjoy more functional experience and all-round security protection brought by Al
water protector,
4, Connect the water leakage protector A to the power adaptor,
2, APP download: Android users: Please use the browser to scan code download:
For Apple usors: soarch "Al Water protector” in APP store or scan the QR code
below with wechat scan function,
-13-3. Tum on WIFI on the phone to ensure that the signal is stable and connected
4, Open the APP, register the APP and log in according to the user's situation;
5, After the screen is lit up, long touch the “Query” key and the “Protect/Unprotect”
key at the same time, When the WIFI icon on the screen jumps, the device is
equipped with network,
Android phone:
1) AP Network Distribution: On the "My Device" interface, click "+", select "AP
network Distribution” to enter the "Add Device" interface, click "Add Device
distribution” to enter the "Bind Device" interface, enter the WIFI password, click
"Configure the device to access the Internet, the prompt box" Please manually
connect the SSID of the module! To access the WLAN Settings screen, select
bsk_softap network from the list, and return to the APP application. After the
network is configured successfully, device information is displayed on the My
Devices screon.
2) SmartLink Network Configuration: On the My Devices screen, tap + and select
‘smartLink Network Configuration. On the Bind Device screen, enter the WIFI
password, and tap Configure the Device to access the Intemet. After the network
configuration is successful, the My Devices screen displays the device
information,
IPhone
1) AP Network allocation: On the "My Devices" screen, tap "+" to enter the "Add
Device” screen, tap "AP Network allocation” to enter the "Bind Device” screen, and
-14-enter the Wi-Fi password. Click "Next", and the prompt "Please connect Wi-Fi to
the device AP SSID:bsk_softap, and then retum to APP" appears. Manually enter
the WLAN Settings, connect the network to "bsk_softap", and return to the APP
application.
‘After the network configuration is successful, device information will be displayed
on the "My Devices" interface,
2) SmartLink Network Configuration: On the My Devices page, tap + to switch to
the Add Device page, tap Smartlink Network Configuration to switch to the Bind
Device page, enter the WieFi password, and tap Next. After the network
configuration is successful, device information is displayed on the My Devices
page. Please go to "Product Description” in the "My page” of the APP to lear
about the operation and functions of the APP.
Remarks
Please make sure that the WiFi of the mobile phone is connected and the signal is
good. It will take 90 seconds to complete the network configuration.
TRANSPORTATION AND STORAGE
1. Handle the instrument carefully during transportation to avoid severe impact.
2. The storage environment temperature (1-50)°C, relative humidity less than
80%, protect against strong electromagnetic field and direct sunlight.
3, The products stored in the code should be at least 30cm away from the ground,
at least 1m away from the four walls, and at least 2m away from the heating
equipment,
4, Keep the warehouse dry, free of corrosive goods, gas and dangerous goods.
-15=VEVOR’
TOUGH TOOLS, HALF PRICE
Technical Support and E-Warranty Certificate
www.vevor.com/support