You are on page 1of 15

Weighing Indicator

K3HB-V CSM_K3HB-V_DS_E_11_6

An Ideal Indicator for OK/NG Judgements in Automated and


Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
• Easy recognition of judgement results using color display that can be switched
between red and green. *
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimination
applications.
• Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC
power takeoff also available.)
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or 97 mm
for DeviceNet models.
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66). For the most recent information on models that have been certified for
• Capable of high-speed sampling at 50 times per second (20 ms) safety standards, refer to your OMRON website.
• Easy-to-set two-point scaling allows conversion and display of any user-set values.
* Visual confirmation of judgement results is not supported on models that do not have an Refer to Safety Precautions for All Digital Panel
output or models that do not support DeviceNet. Meters.
You can change the display color by setting it, but you cannot switch it based on the judgement results.

Model Number Structure


„Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units Base Units with Optional Boards
K3HB-V@ K3HB-V@-@@@
1 5 1 2 3 4 5
1. Input Sensor Code 2. Sensor Power Supply/Output Type Code
None:
None
LC: Load cell input (DC low-voltage input) CPB:Relay output (PASS: SPDT) + Sensor power supply
5. Supply Voltage (10 VDC +/−5%, 100 mA) (See note 1.)
L1B: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power
100-240 VAC: 100 to 240 VAC supply (10 VDC +/−5%, 100 mA) (See note 2.)
L2B: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor
24 VAC/VDC: 24 VAC/VDC power supply (10 VDC +/−5%, 100 mA) (See note 2.)
B: Sensor power supply (10 VDC +/−5%, 100 mA)
FLK1B: Communications (RS-232C) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
FLK3B: Communications (RS-485) + Sensor power supply
(10 VDC +/−5%, 100 mA) (See note 2.)
CPE: Relay output (PASS: SPDT) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note1.)
L1E: Linear current output (DC0(4) −20 mA) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
L2E: Linear voltage output (DC0(1) −5 V, 0−10 V)+ Sensor power
supply (5 VDC +/−5%, 100 mA) (See note 2.)
E: Sensor power supply (5 VDC +/−5%, 100 mA)
FLK1E: Communications (RS-232C) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
FLK3E: Communications RS-485) + Sensor power supply
(5 VDC +/−5%, 100 mA) (See note 2.)
Note: 1. CPA can be combined with relay outputs only.
2. Only one of the following can be used by each Digital Indicator: RS-
232C/RS-485 communications, a linear output, or DeviceNet
communications.
Optional Boards
Sensor Power Supply/Output Boards 3. Relay/Transistor Output Type Code
None: None
K33-@ C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
2 T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
Relay/Transistor Output Boards T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
K34-@ DRT: DeviceNet (See note 2.)
* A Special BCD Output Cable (sold separately) is required.
3
4. Event Input Type Code
Event Input Boards None: None
1: 5 inputs (M3 terminal blocks), NPN open collector
K35-@ 2 *: 8 inputs (10-pin MIL connector), NPN open collector
4 3: 5 inputs (M3 terminal blocks), PNP open collector
4 *: 8 inputs (10-pin MIL connector), PNP open collector
* There is no bank selection for "None" and "DeviceNet" types of "Transistor
Output Type Code".
Note: The following combinations are not possible.
• Communications (FLK@B/E) + DeviceNet (DRT)
• Communications (FLK@B/E) + BCD output (BCD)
• Linear current/voltage (L@B/E) + DeviceNet (DRT)

1
K3HB-V
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs, with 8-pin connector)
K32-BCD: Special BCD Output Cable

Watertight Cover Rubber Packing


Model Model
Y92A-49N K32-P1
Note: Rubber packing is provided with the Controller.

Specifications
„Ratings
Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC
Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC
Power consumption 100 to 240 V: 18 VA max. (max. load)
(See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load)
Current consumption DeviceNet power supply: 50 mA max. (24 VDC)
Input DC voltage
A/D conversion method Delta-Sigma method
External power supply 10 VDC ±5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA (models with external
power supply only)
Event inputs Timing input NPN open collector or no-voltage contact signal
(See note 2.) ON residual voltage: 3 V max.
ON current at 0 Ω: 17 mA max.
Max. applied voltage: 30 VDC max.
OFF leakage current: 1.5 mA max.
Startup compensation NPN open collector or no-voltage contact signal
timer input ON residual voltage: 2 V max.
Hold input ON current at 0 Ω: 4 mA max.
Max. applied voltage: 30 VDC max.
Reset input OFF leakage current: 0.1 mA max.
Forced-zero input
Bank input
Output ratings (depends Relay output 250 VAC, 30 VDC, 5 A (resistive load)
on the model) Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations
Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 μA max.
Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC:
Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS
Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC:
Load: 5 kΩ max, Resolution: Approx. 10,000, Output error: ±0.5% FS
(1 V or less: ±0.15 V; no output for 0 V or less)
Display method Negative LCD (backlit LED) display
7-segment digital display (Character height: PV: 14.2 mm (green/red); SV: 4.9 mm (green)
Main functions Scaling function, measurement operation selection, averaging, previous average value comparison, forced-
zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display
color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset
Ambient operating temperature −10 to 55°C (with no icing or condensation)
Ambient operating humidity 25% to 85%
Storage temperature −25 to 65°C (with no icing or condensation)
Altitude 2,000 m max.
Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include
a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note
3.)

Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required
when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended.
2. PNP input types are also available.
3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables.

2
K3HB-V
„Characteristics
Display range −19,999 to 99,999
Sampling period 20 ms (50 times/second)
Comparative output response time 100 ms max.
Linear output response time 150 ms max.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 2,300 VAC for 1 min between external terminals and case
Noise immunity 100 to 240 VAC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
24 VAC/VDC models:
±1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 μs/100 ns)
Vibration resistance Frequency: 10 to 55 Hz; Acceleration: 50 m/s2, 10 sweeps of 5 min each in X, Y, and Z directions
Shock resistance 150 m/s2 (100 m/s2 for relay outputs) 3 times each in 3 axes, 6 directions
Weight Approx. 300 g (Base Unit only)
Degree of Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection Rear case IP20
Terminals IP00 + finger protection (VDE0106/100)
Memory protection EEPROM (non-volatile memory)
Number of rewrites: 100,000
Applicable standards UL61010-1, CSA C22.2 No. 61010-1-04
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326-1
EMC EMI: EN61326-1 Industrial electromagnetic environment
Electromagnetic radiation interference
CISPR 11 Group 1, Class A
Terminal interference voltage
CISPR 11 Group 1, Class A
EMS: EN61326-1 Industrial electromagnetic environment
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0°/180°, 100% (rated voltage)

3
K3HB-V
„Input Ranges (Measurement Range and Accuracy)
Input type Range Set value Measurement range Input impedance Accuracy Allowable
instantaneous
overload (30 s)
K3HB-VLC A a lc 0.00 to 199.99 mV 1 MΩ min. ±0.1% rdg ±1 digit max. ±200 V
Load Cell, mV B b lc 0.000 to 19.999 mV ±0.1% rdg ±5 digits max.
C c lc ±100.00 mV ±0.1% rdg ±3 digits max.
D d lc ±199.99 mV ±0.1% rdg ±1 digit max.

Note: 1. The accuracy is for an ambient temperature of 23±5°C. For all ranges,10% or less of max. input ±0.1% FS.
2. The letters “rdg” mean “reading.”

Input type a lc b lc c lc d lc
Connected E2 E6 E3 E6 E4 E6 E5 E6
terminals
(mV) 199.99 199.99
200.000
150.000
100.00
100.000
19.999
50.000
0.00
0.00 0.000
−50.00
−100.00
−100.00
−150.00
−200.00
−199.99
Maximum -19.99 to 219.99 mV -1.999 to 21.999 mV -110.00 to 110.00 mV -199.99 to 219.99 mV
measurement range

The area shown in dark shading indicates the factory setting.

„Load Cell Wiring Example „Scaling Example Using Range A


Indicated on the K3HB-V as 0 to 49N in the load cell specifications
+10 V (10-VDC, 100-mA
B E external power supply) (rated load 49N, recommended applied voltage 10 V, rated output
or 2 mV/V) (See note.)
+5 V (5-VDC, 100-mA
external power supply)
+IN Display value
E2
49 N Scaling values:
E3 inp.a1=000.00
+OUT −OUT dsp.a1=00000
Load cell
E4 + inp.a2=020.00
dsp.a2=49000
B5 E5 −IN
dp decimal point position: 00.000
Input value
20 mV
B6 E6
− Note: “2 mV/V” indicates a load cell output of 2 mV for 1 V applied
voltage for the rated load (when using a load of 1 N). When the
applied voltage is 10 V, the load cell output is 20 mV (2 mV ×
0V
10).
The precision can be increased by entering the A1 and A2 input
values by teaching, and then scaling the results.

4
K3HB-V
Common Specifications
„Event Input Ratings
Input type S-TMR, HOLD, RESET, ZERO, BANK1, BANK2, TIMING
BANK4
Contact ON: 1 kΩ max., OFF: 100 kΩ min. ---
No-contact ON residual voltage: 2 V max. ON residual voltage: 3 V max.
OFF leakage current: 0.1 mA max. OFF leakage current: 1.5 mA max.
Load current: 4 mA max. Load current: 17 mA max.
Maximum applied voltage: 30 VDC max. Maximum applied voltage: 30 VDC max.

„Output Ratings
Contact Output Transistor Output
Item Resistive loads Inductive loads Maximum load voltage 24 VDC
(250 VAC, cosφ=1; (250 VAC, closed
Maximum load current 50 mA
30 VDC, L/R=0 ms) circuit, cosφ=0.4;
30 VDC, L/R=7 ms) Leakage current 100 μA max.
Rated load 5 A at 250 VAC 1 A at 250 VAC
5 A at 30 VDC 1 A at 30 VDC
Rated through 5A
current
Mechanical life 5,000,000 operations
expectancy
Electrical life 100,000 operations
expectancy

Linear Output
Item 0 to 20 mA 4 to 20 mA 0 to 5 V 1 to 5 V 0 to 10 V
Allowable load impedance 500 Ω max. 5 kΩ min.
Resolution Approx. 10,000
Output error ±0.5%FS ±0.5%FS (1 V or less: no output for ±0.15 V; 0 V or less)

Serial Communications Output BCD Output I/O Ratings


Item RS-232C, RS-485 (Input Signal Logic: Negative)
Communications method Half duplex I/O signal name Item Rating
Synchronization method Start-stop synchronization Inputs REQUEST Input signal No-voltage
Baud rate 9,600, 19,200, or 38,400 bps HOLD contact input
MAX Input current for 10 mA
Transmission code ASCII MIN no-voltage input
Data length 7 bits or 8 bits RESET
Signal ON voltage 1.5 V max.
Stop bit length 2 bits or 1 bit level
OFF voltage 3 V min.
Error detection Vertical parity and FCS Outputs DATA Maximum load 24 VDC
Parity check Odd, even POLARITY voltage
OVER Maximum load 10 mA
Note: For details on serial and DeviceNet communications, refer to DATA VALID current
RUN Leakage current 100 μA max.
the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).
HH Maximum load 24 VDC
H voltage
PASS Maximum load 50 mA
L current
LL Leakage current 100 μA max.

Note: For details on serial and DeviceNet communications, refer to


the Digital Indicator K3HB Communications User's Manual
(Cat.No. N129).

5
K3HB-V
DeviceNet Communications
Communications protocol Conforms to DeviceNet
Supported communi- Remote I/O communications Master-Slave connection (polling, bit-strobe, COS, cyclic)
cations Conforms to DeviceNet communications standards.
I/O allocations Allocate any I/O data using the Configurator.
Allocate any data, such as DeviceNet-specific parameters and variable area for Digital
Indicators.
Input area: 2 blocks, 60 words max.
Output area: 1 block, 29 words max.
(The first word in the area is always allocated for the Output Execution Enabled Flags.)
Message communications Explicit message communications
CompoWay/F communications commands can be executed (using explicit message
communications)
Connection methods Combination of multi-drop and T-branch connections (for trunk and drop lines)
Baud rate DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)
Communications media Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)
Communications distance
Baud rate Network length Drop line length Total drop line
(max.) (max.) length (max.)
500 Kbps 100 m (100 m) 6m 39 m
250 Kbps 100 m 6m 78 m
(250 m)
125 Kbps 100 m 6m 156 m
(500 m)
The values in parentheses are for Thick Cable.
Communications power supply 24-VDC DeviceNet power supply
Allowable voltage fluctuation range 11 to 25-VDC DeviceNet power supply
Current consumption 50 mA max. (24 VDC)
Maximum number of nodes 64 (DeviceNet Configurator is counted as one node when connected)
Maximum number of slaves 63
Error control checks CRC errors
DeviceNet power supply Supplied from DeviceNet communications connector

„Internal Block Diagram

Analog input Input


circuit
ADC Keys

EEP-ROM Indications

BCD
• Input circuit Drive Transistor
BCD I/O Drive
• Output circuit
• Transistor
circuit circuit output
output circuit
Micro-
computer
Event input Digital input Waveform Drive
circuit shaping circuit circuit
X Relay output

Linear output Drive Drive DeviceNet


Linear output circuit DeviceNet
circuit circuit circuit

Sensor power Drive Communi-


supply Filter circuit
cations Communications
driver

VO VDD VCOM

VO
Power supply circuit (isolated) DC-DC

Converter (isolated)

Power supply

6
K3HB-V
„Power Supply Derating Curve for Sensor (Reference Value)
With 12 V With 10 V

Max. current (mA) Max. current (mA)


140 140
(1) (1)
120 120

100 100

80 80

60 60

40 40

20 20

0 0
20 10 0 10 20 30 40 50 60 20 10 0 10 20 30 40 50 60

Ambient temperature (qC) Ambient temperature (qC)

Note: 1. The above values are for standard mounting. The derating curve differs depending on the mounting conditions.
2. Do not use the Sensor outside of the derating area (i.e., do not use it in the area labeled (1) in the above graphics). Doing so may occa-
sionally cause deterioration or damage to internal components.

„Component Names and Functions


Max/Min status indicator PV display
Turns ON when the maximum value or minimum value is Displays PVs, maximum values,
displayed in the RUN level. minimum values, parameter
names, and error names.

Level/bank display Position meter


In RUN level, displays the bank if the bank function is Displays the position of the PV with
ON. (Turns OFF if the bank function is OFF.) respect to a desired scale.
In other levels, displays the current level.

Comparative output SV display


status indicators HH Max
Displays SV and monitor values.
H Min
Display the status of comparative outputs. P
L
L
T-ZR CMW TG HH H
LL Zero Hold T LL L

Status indicators SV display status indicators


MAX/MIN LEVEL MODE SHIFT UP
Display Function Display Function
Turns ON when the tare zero function is
executed. Turns OFF if it is not executed or Turns ON when the timing signal turns
T-ZR TG ON. Otherwise OFF.
is cleared.
Turns ON when the forced-zero function is
Zero executed. Turns OFF if it is not executed or Turns ON when parameters for which
is cleared. (Excluding the K3HB-H.) T teaching can be performed are
displayed.
Turns ON/OFF when hold input turns In RUN level, turn ON when the
Hold ON/OFF. HH, H,
comparative set values HH, H, L, and
L, LL LL are displayed.

MAX/MIN Key LEVEL Key MODE Key SHIFT Key UP Key


Used to switch the Used to switch level. Used to switch the Used to change When changing a set value,
display between the parameters displayed. parameter settings. this key is used to change
PV, maximum value, When changing a set the actual value.
and minimum value and value, this key is used When a measurement value
to reset the maximum to move along the is displayed, this key is
and minimum values. digits. used to execute or clear the
forced-zero function or to
execute teaching.

7
K3HB-V
„BCD Output Timing Chart
A REQUEST signal from a Programmable Controller or other external device is required to read BCD data.

Single Sampling Data Output Continuous Data Output


20-ms pulse min. (50 ms max.)
REQ.
REQ. MAX.MIN.
MAX.MIN.
DATA All data "High" Data 1 Data 2
DATA All data "High" Data All data "High"
DATA
DATA VALID
VALID
40 ms 40 ms
Approx. Approx. 24 ms 24 ms
30 ms 40 ms 30 ms 64 ms 64 ms
16 ms

The data is set in approximately 30 ms from the rising edge of the Measurement data is output every 64 ms while the REQUEST signal
REQUEST signal and the DATA VALID signal is output. remains ON.
When reading the data from a Programmable Controller, start
Note: If HOLD is executed when switching between data 1 and data
reading the data when the DATA VALID signal turns ON.
2, either data 1 or data 2 is output depending on the timing of
The DATA VALID signal will turn OFF 40 ms later, and the data will
the hold signal. The data will not go LOW.
turn OFF 16 ms after that.

REQ. (1)
K3HB
(1)
Programmable
Controller REQ. (2)

K3HB
REQ. (3)
(2)
DATA (including POL and
OVER) and DATA VALID can
be used in a wired OR. DATA (1) (2) (3)
K3HB RUN, HH, H, PASS, L, and
(3) LL are always output, with or
without a REQUEST signal. DATA
Do not used a wired OR VALID
(See note.) (See note.) (See note.)
connect for these signals.
Note: Leave 20 ms min. between DATA VALID turning OFF and the REQUEST signal.

Programmable Controller Connection Example Display Unit Connection Example


Digital Indicator SYSMAC Programmable Controller Digital Indicator
Connector pin No. (See note.) DC Input Unit Connector pin No. (See note.)
1.COMMON COM 1.COMMON

2.1 IN 2.1

3.2 IN 3.2
10° 10°
4.4 4.4
Internal circuit

IN

5.8 IN 5.8

23.DATA VALID 23.DATA VALID


24.RUN IN 24.RUN

IN To 101

To 102

25.COMMON Transistor Output Unit 25.COMMON


Short-
26.REQUEST OUT 26.REQUEST circuit
+5 V 240 Ω +5 V 240 Ω
Internal circuit

Internal circuit

240 Ω 240 Ω

30.RESET OUT 30.RESET


240 Ω 240 Ω
V
O
D
C
B
A
DP
LE
V
O
D
C
B
A
DP
LE
V
O
D
C
B
A
DP
LE
V
O

31.POLARITY COM 31.POLARITY


240 Ω 240 Ω
(+/− polarity) (0 V) (+/− polarity) 8 8 8 SEC
24 VDC M7E-01D@N2, 01H@N2

* <M7E Digital Display Unit>


+24 V
DC power Note: The BCD output connector pin number is the D-sub connector pin number when
0V supply the BCD Output Cable (sold separately) is connected. This number differs from
the pin number for the Digital Indicator narrow pitch connector (manufactured by
Honda Tsushin Kogyo Co., Ltd.).
*M7E series were discontinued at the end of March, 2020.

Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator:
K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128)
The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp

8
K3HB-V
„Connections
Terminal Arrangement
Note: Insulation is used between signal input, event input, output, and power supply terminals.

A B C D E
A Operating Power Supply 1
2
100 to 240 VAC 3
24 VAC/ VDC
4
5
A1
6
A2

*Check the required power supply type.

B Sensor Power Supply/Output

Sensor power supply + C Relays, Transistors, BCD and DeviceNet


PASS output
B1

PASS B2
Relay Outputs Relay Outputs Transistor Outputs DeviceNet Connector (Included)
<C1> <C2> <T1> <T2> <DRT>
B3
NPN PNP
Sensor power supply

C1 HH C1 HH C1

1 2 3 4 5
N/C B4
10 VDC 100 mA

12 VDC 80 mA
5 VDC 100 mA

+ H C2 H C2 H C2
B5
C3 COM C3 PASS C3
B6
− C4 L C4 L C4
<K33- <K33- <K33- 1: V− (Power supply cable: Black)
CPE> CPB> CPA> L C5 LL C5 LL C5 2: CAN L (Communications cable: Blue)
Sensor power supply + 3: Shield
C6 COM C6 COM C6 4: CAN H (Communications cable: White)
linear output 5: V+ (Power supply cable: Red)
+ Applicable Connector:
0-5/1-5/ 0-5/1-5/ 0-5/1-5/ B1 HR31-5.08P-5SC (01)
N/C N/C N/C (HIROSE ELECTRIC CO., LTD.)
0-10 V 0-10 V 0-10 V * Attach the provided crimp terminals.
− B2 BCD (NPN Open Collector): BCD
+
B3 Applicable Connector (Sold separately)
0-20/ 0-20/ 0-20/
Sensor power supply

N/C N/C N/C HDR-E50MAG1


4-20 mA 4-20 mA 4-20 mA
− B4 (HONDA TSUSHIN KOGYO CO., LTD.)
10 VDC 100 mA

10 VDC 100 mA
5 VDC 100 mA

12 VDC 80 mA
12 VDC 80 mA
5 VDC 100 mA

+ Special Cable (Sold separately)


B5
K32-BCD (OMRON)
− B6 (HDR-E50MAG1 with 0.3-m cable)

<K33- <K33- <K33- <K33- <K33- <K33-


L2E> L1E> L2B> L1B> L2A> L1A> The BCD COMMON is shared.
Sensor power supply The pins indicated in the above diagram
as blank (white) boxes have been removed.
B1 *Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet.

B2
N/C Contact output Transistor Output
B3
(NPN Open Collector)
Sensor power supply

B4
10 VDC 100 mA
5 VDC 100 mA

12 VDC 80 mA

+ 5V
B5

B6 HH HH

<K33-E> <K33-B> <K33-A> H H
Sensor power supply + L L
communications
LL LL
B (+) SD B (+) SD B (+) SD B1 PASS PASS
A (−) RD A (−) RD A (−) RD B2

B (+) SG B (+) SG B (+) SG B3


Sensor power supply

A (−) N/C A (−) N/C A (−) N/C B4


Safety Standards Conformance
10 VDC 100 mA

10 VDC 100 mA

12 VDC 80 mA

12 VDC 80 mA
5 VDC 100 mA

5 VDC 100 mA

+
B5
• Always use a EN/IEC-compliant power supply with reinforced insulation or
B6
− double insulation for the DeviceNet power supply.
RS-485 RS-232C RS-485 RS-232C RS-485 RS-232C
<K33- <K33- <K33- <K33- <K33- <K33-
• The product must be used indoors for the above applicable standards to
FLK3E> FLK1E> FLK3B> FLK1B> FLK3A> FLK1A>
apply.
• The K3HB-XVA@@ complies with UL standards when the applied input
voltage is within the range 0 to 150 VAC.

9
K3HB-V

E Analog Input

Process Indicator Weighing Indicator Temperature Indicator Linear Sensor Indicator


K3HB-X K3HB-V K3HB-H K3HB-S
AC voltage only

E1 N/C A, B E1 N/C E1 E1 Input B

E2 A N/C E2 A E2 Current input E2 Input A


N/C
E3 B C E3 B E3 E3 COM
A
E4 C D E4 C E4 Voltage input E4 Input A
Pt
-
E5 D N/C E5 D E5 E5 Input B
B TC
E6 COM COM E6 COM E6 COM N/C E6
B' +

D Event Input
• Use terminal pin D6 as the common terminal.
Models with Terminal Blocks
<K35-1><K35-3> • Use NPN open collector or no-voltage contacts for event input.
PNP types are also available.
D1 TIMING
12 V 12 V
D2 S-TMR S-TMR: D2
HOLD: D3
D3 HOLD RESET: D4
ZERO: D5 4.7 kΩ TIMING 560 Ω
D4 RESET

D5 ZERO D1
3.9 kΩ 750 Ω
D6 COM

Models with Connectors D6 D6


COM COM
<K35-2><K35-4>
1: TIMING 2: S-TMR
1 2
3: HOLD 4: RESET
5: ZERO 6: COM
7: BANK4 8: BANK2
9: BANK1 9 10 10: COM

• Applicable Connector (Sold separately)


XG4M-1030 (OMRON)
• Special Cable (Sold separately)
K32-DICN (OMRON)
(XG4M-1030 with 3 m cable)

BCD Output Cable


Model Shape Pin arrangement
K32-BCD 1
COMMON 20 4 104
1 2
21 8
100 2 3
22 OVER
Connected device end 4 4
23 DATA VALID
K3HB end (PLC, display device, etc.) 8 5
24 RUN
1 6
25 COMMON
2 7
REQUEST
101 4 8
26
27 MAX REQ.
8 9
28 MIN REQ.
1 10
29 HOLD
2 11
RESET
102 30
4 12
31 POLARITY
8 13
32 HH
1 14
33 H
300 mm 2 15
PASS
38 mm 46.5 mm 103 34
4 16
35 L
8 17
36 LL
1 18
COMMON
104 2 19
37

Note: The BCD Output Cable has a D-sub plug.

Special Cable (for Event Inputs with 8-pin Connector)


Model Appearance Wiring
K32-DICN Pin No. Signal name
1 TIMING
9 10 2 S-TMR
3 HOLD
1 2 4 RESET
3,000 mm 5 ZERO
Cable marking (3 m)
6 COM
7 BANK4
8 BANK2
9 BANK1
10 COM

10
K3HB-V
„Main Functions
Measurement
Timing Hold

Normal Sampling Hold


• Continuously performs measurement and always outputs based on • Holds the measurement at the rising edge of the TIMING signal.
comparative results.
Input Sampling hold value
Input

H comparative set value


Measurement value
Measurement value
Time
Time TIMING ON
input OFF
H output
Peak-to-peak Hold
Peak Hold/Bottom Hold • Measures the difference between the maximum and minimum val-
• Measures the maximum (or minimum) value in a specified period. ues in a specified period.
Input Peak hold value Input Peak-to-peak value

(b2−a2)
(b1−a1)
Measurement value
Measurement value b1 'b2
Bottom hold value a1 'a2

Time Time
TIMING ON TIMING ON
input OFF input OFF

Scaling Previous Average Value Comparison

Scaling converts input signals in any way required before displaying Slight changes can be removed from input signals to detect only
them. The values can be manipulated by shifting, inverting, or +/– extreme changes.
reversing.
Display value Display value

Display value 2 Display value 2


(dsp.a2) (dsp.a2)

Display value 1 Display value 1


(dsp.a1) (dsp.a1)

Input value 1 Input value 2 Input value 2 Input value 1 Input value
(inp.a1) (inp.a2) Input value (inp.a2) (inp.a1)

(Scaling) (Reverse scaling)

Teaching

Settings for scaling can be made using the present measurement


values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making settings while monitoring the
operating status, for calculating amounts by tare reduction (to
measure only the contents), or when the result should be zero but
the display is not zero for some reason.

Standby Sequence

Turns the comparative output OFF until the measurement value


enters the PASS range.
Average Processing

Average processing of input signals with extreme changes or noise


smooths out the display and makes control stable.

11
K3HB-V
„Input Compensation/Display
Forced-zero Display Value Selection

The current display value can be selected from the present value,
Forces the present value to 0. (Convenient for setting reference val- the maximum value, and the minimum value.
ues or deducting tares for weight measurement.)
Step Value
Tare Zero

It is possible to specify (i.e., restrict) the values that the smallest dis-
Shifts the current value measured with a forced zero to 0 again. It is played digit can change by. For example, if the setting is 2, the small-
possible to measure two or more compounds separately and then, est digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,
by releasing the tare zero and forced-zero, measure the combined it will only take the values 0 or 5. If the setting is 10, it will only take
total. the value of 0.
Zero-trimming

Compensates for mild fluctuations in input signals due to factors


such as sensor temperature drift, based on OK (PASS) data at mea-
surement. (This function can be used with sampling hold, peak hold,
or bottom hold.)
Zero-limit

Changes the display value to 0 for input values less than the set
value. It is enabled in normal mode only. (This function can be used,
for example, to stop negative values being displayed or to eliminate
flickering and minor inconsistencies near 0.)

Display

Zero-limit
setting

Input

Interruption Memory

• The minimum and maximum values when the power supply is


turned OFF can be saved if interruption memory is turned ON.
• If interruption memory is ON, the maximum and minimum values
after the last resetting will be displayed.
• If interruption memory is OFF, the maximum and minimum values
will be displayed after the power supply is turned ON (or after the
reset input is performed).

Display Refresh Period

The display refresh period can be lengthened to reduce flickering


and thereby make the display easier to read.
Display Color Selection

Values can be displayed in either red or green. With comparative out-


put models, the display color can also be set to change according to
the status of comparative outputs (e.g., green to red or red to green).

Example) Setting: grn-r


Red
H
110.01
110.00
Comparative set value H
Green

P 100.05
Comparative set value L 110.00

L
99.87
110.00
Red

12
K3HB-V
„Output

Comparative Output Pattern Hysteresis

The output pattern for comparative outputs can be selected. In addi- Prevents comparative output chattering when the measurement
tion to high/low comparison with set values, output based on level value fluctuates slightly near the set value.
changes is also possible. (Use the type of output pattern appropriate
for the application.) Example: Comparative Output Pattern (Standard Output)
Hysteresis
Comparative set value H Hysteresis
Comparative Standard Output Measurement Level Output Measurement
value Comparative value
set value HH set value HH
Comparative Higher Comparative Higher Comparative set value L
set value H set value H
Comparative Comparative
set value L set value L
Comparative Lower Comparative Lower Comparative output H
set value LL set value LL
Output HH ON Output HH ON Comparative output L
Output H OFF Output H OFF
Output PASS
Startup Compensation Timer
Output PASS
Output L Output L
Output LL Output LL
Measurement can be stopped for a set time using external input.
Measurement
Comparative Zone Output value Input
set value HH
Comparative Higher
set value H H comparative set value
Comparative
set value L
Comparative Lower
set value LL
Output HH ON
Output H OFF Time
Output PASS
H output Startup
Output L compensation
Output LL time set time
H input

Output Logic
PASS Output Change

Reverses the output operation of comparative outputs for compara-


tive results. Comparative results other than PASS and error signals can be output
from the PASS output terminal.

„Dimensions
101.2 Terminal cover (included)
91
Character Size for Main Display (mm) Panel Cutout Dimensions
PV display SV display 120 min.

14.2 4.9

100
3.5
(112)
7.6
75 min.
92+0.8
0

12 45+0.6
0
1.3
95*
2
96
Mounting Recommended Panel Thickness
1 to 8 mm.
Mount the product horizontally.
48 44.8

*DeviceNet models: 97 mm
Terminal: M3, Terminal Cover: Accessory

13
K3HB-V
„Wiring Precautions „Mounting Method
• For terminal blocks, use the crimp terminals suitable for M3 screws. 1. Insert the K3HB into the mounting cutout in the panel.
• Tighten the terminal screws to the recommended tightening torque 2. Insert watertight packing around the Unit to make the mounting
of approx. 0.5 N⋅m. watertight.
• To prevent inductive noise, separate the wiring for signal lines from Watertight
that for power lines. packing

Wiring
• Use the crimp terminals suitable for M3 screws shown below.

5.8 mm max.

5.8 mm max.
3. Insert the fixture into the grooves on the left and right sides of the
rear case and push until it reaches the panel and is fixed in place.

Unit Stickers Fixture

• Select the appropriate units from the unit sticker sheets provided
and attach the sticker to the Indicator.

„LCD Field of Vision


The K3HB is designed to have the best visibility at the angles shown
in the following diagram.
Note: When using for meters, such as weighing meters, use the units
specified by regulations on weights and measures.

10°

30°

„Watertight Cover
Y92A-49N

„Rubber Packing
K32-P1
If the rubber packing is lost or damaged, it can
be ordered using the following model number:
K32-P1.

(Depending on the operating environment


deterioration, contraction, or hardening of the
rubber packing may occur and so, in order to
ensure the level of waterproofing specified in
NEMA4, periodic replacement is
recommended.)
Note: Rubber packing is provided with the
Controller.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

In the interest of product improvement, specifications are subject to change without notice.

14
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.

Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.

Limitation on Liability; Etc.


OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.

Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.

Errors and Omissions.


Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

2023.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2023 All Right Reserved.