LEGEND:

1000 EXISTING MAJOR (10') CONTOUR


SEE C-202 SEE C-203
1020
1020

10
1 1020 2 EXISTING MINOR (2') CONTOUR

20
10
1010
0

10
102
C-207 C-207
20

EXISTING FENCE

1020
X X X
10

10
20 103020 EXISTING CULVERT
101010
10 0
22
10

10 0 ROW BOUNDARY
1020

1020
20

GOTION PROPERTY BOUNDARY


0

102
1010
101

0
EXISTING EASEMENT BOUNDARY

100
0
1020 1020 1020 1020
NORTH W-E RD EXISTING PARCEL BOUNDARY

1014

0
1014

99
1020

OE OE EXISTING OVERHEAD ELECTRIC

EXISTING GRAVEL EXTENT

1020
1020

EXISTING WETLAND
986' 986'
20 30
10
10 990 EXISTING BUILDING
980

1010
990

1020
103
10 0

WEST N-S RD

98
NW BUILDING

815'

815'
20 NE BUILDING

97
EXISTING PAVEMENT SURFACE

MID N-S RD

0
1015.0 1015.0

960
0
1030

1000
10

980 960

EAST N-S RD
20

970

30
960 D D EXISTING DISTRICT WATERSHED BOUND.

10
950

990

950
1 EXISTING SUBWATERSHED BOUNDARY
C-206 PROPOSED BASIN
PROPOSED RETAINING WALL 950.0
10

980
EXISTING STREAM REACH

PHASE 2

PHASE 2
950
30

PROPOSED PUBLIC CEC OVERHEAD PHASE BOUNDARY

0
960

97
WATER SUPPLY SURFACE FLOW DIRECTION
ELECTRIC EASEMENT

950
970

950
1030

950
CEC SUBSTATION
1030

960
1026.8 GOTION PROPERTY BOUNDARY
|

P/L P/L
|
|
140'

PHASE 1

PHASE 1
|

0
|

97
|

12
1000 PROPOSED MAJOR (10') CONTOUR
220TH AVE

10
1034
1024

950
2
4
6
0
8
2
6

960
96 PROPOSED MINOR (2') CONTOUR
103
102

10W28 1002
1030
101
101
101

PARKING
102
101
102
102

MID W-E RD PARKING MID W-E RD


1010 0

96
W W W W W W W W W W W W W W W
0
8

0
1008.0
PROPOSED SPOT ELEVATION
SEE
1100C-204 SEE08 C-205
0
1100220
1020

20
200
102 10
2

|
|
10

|
|

|
|

|
|

|
|

|
|

PROPOSED WETLAND IMPACTS


|
|

PROPOSED PROPOSED NITROGEN


|
335'
|

28
|

|
|

10
|

40'x60' DTE STORAGE & EQUIPMENT AREA


|
|
CADD USER: JACOB M. DAIRE FILE: M:\DESIGN\22541027 GOTION US ENV ASSISTANCE\WORK FILES\DRAWINGS\22541027.07_C-201 PROPOSED OVERALL.DWG PLOT SCALE: 1:1 PLOT DATE: 2/27/2024 3:59 PM

|
|

|
445'

METERING 1017.0
|

PARKING
|

|
|

PROPOSED EASEMENT BOUNDARY


|

STATION
|

|
|

6
|
|

525'
02
|
|

986' 986'
|

1
|

960
|

PROPOSED SUBWATERSHED BOUNDARY


|
|

950
|

|
|

|
|

|
|

4 PROPOSED RETAINING WALL


|
|

2
|

10
|

PROPOSED CULVERT/DRAINTILE
1020
|
|
1030

611'
|

2
0

|
2

PROPOSED BASIN
10

C-206 1014.4 PROPOSED STREAM REACH


PROPOSED RETAINING WALL PROPOSED BASIN
944.0
815'

815'
4
20 94 PROPOSED RETAINING WALL
| | | | | | | | | | |

SW BUILDING SE BUILDING
1030

10
1010
30

1008.0 1008.0
PROPOSED WATER SUPPLY
10

W W
1020
1030
1030

950
96
1020

1000
1020

WASTE 0

950
960
1020
20

WATER
10

TREAT-

960
990
MENT

950
1004.0

950
960

980
06 REFERENCES:
10 PHAS
4
1030 100
6 100 1006 PROPOSED COUNTY E 1

96 970
4 100 1. PROPOSED SITE LAYOUT FROM "MICHIGAN PROJECT
0 100 1002 4 DRAINAGE CHANNEL GENERAL LAYOUT (ADDING TRUCK PARKING AREA)
103

0
10

SOUTH W-E RD
1002 2023.02.06.dwg", RECEIVED BY BARR ON 2-8-2024.
3

1000
0

1000 BUILDING BUILDING 998 PROPOSED 16" WIDE 2. EXISTING TOPOGRAPHY FROM LIDAR/SURVEY COMPLETED
960
30 998 996 GRAVEL ACCESS ROAD BY DLZ IN NOVEMBER 2023.
10
1030

994
996
10

00

994 992
10
20

PARKING PARKING 3. EXISTING SITE BOUNDARIES FROM ALTA SURVEY


10

992
10

990
10

COMPLETED BY EXXEL ENGINEERING, INC. IN AUGUST 2023.


30

990 988 960 960


FRONTAGE RD 952 4. WETLAND DELINEATION BASED ON STATE OF MICHIGAN
980 960

0
960 (DEPARTMENT OF ENVIRONMENT, GREAT LAKES AND

97
18 MILE RD ENERGY) WETLAND IDENTIFICATION REPORT DATED OCT.
23, 2023.
990 98 970 PROPOSED 100' WIDE
0
EASEMENT BOUNDARY 5. COORDINATE SYSTEM CORRESPONDS TO NAD83 MICHIGAN

0
96
STATE PLANE, SOUTH ZONE, INTERNATIONAL FOOT.
VERTICAL DATUM OF NAVD88.

NOTES: SITE DEVELOPMENT.

1 PLAN: OVERALL PROPOSED 1. PHASE 1 TO INCLUDE SOUTHERN 2 BUILDINGS (SW AND SE) AND SITE ROADS, 7. SITE ENTRANCE FROM 220TH AVE AND 18 MILE SHALL BE IN ACCORDANCE WITH
- PARKING, STORMWATER PONDS ETC, AS SHOWN ABOVE. MICHIGAN DEPARTMENT OF TRANSPORTATION (MDOT) AND MECOSTA COUNTY
0 200 400 ROAD COMMISSION REQUIREMENTS.
N 2. RELOCATION OF COUNTY DRAIN, INCLUDING ALL COUNTY DRAIN
SCALE IN FEET IMPROVEMENTS THAT MAY BE REQUIRED AS PART OF THIS DEVELOPMENT, ARE 8. ALL STREETS SHALL BE DEVELOPED IN ACCORDANCE WITH THE THE COUNTY
INTENDED TO BE INCLUDED AS PART OF PHASE 1 CONSTRUCTION ACTIVITIES. ROAD COMMISSION DESIGN SPECIFICATIONS. THE ARRANGEMENT OF PUBLIC
OR COMMON WAYS FOR VEHICULAR AND PEDESTRIAN CIRCULATION SHALL
3. CONSUMERS
DISCUSSIONSENERGY ELECTRICAL
WITH CMS SERVICES
ENERGY FOR ARE ON
ELECTRICAL GOING. ARE ON GOING.
SERVICES RESPECT THE PATTERN OF EXISTING OR PLANNED STREETS. STREETS AND
DRIVES SHALL BE OF AN APPROPRIATE WIDTH TO MEET THE VOLUME OF
4. DTE NATURAL WITH
DISCUSSIONS GAS SERVICES ARE ON GOING.
DTE FOR NATURAL GAS SERVICES ARE ON GOING. TRAFFIC THEY ARE PLANNED TO CARRY AND SHALL HAVE A DEDICATED

5. EXISTING EASEMENTS PRESENT ACROSS THE SITE SHALL BE REMOVED OR


RIGHT-OF-WAY EQUAL TO THAT SPECIFIED IN A COUNTY RECOGNIZED SOURCE FOR SITE
OF REFERENCE.
RELOCATED, AS REQUIRED, TO ACCOMMODATE SITE DEVELOPMENT. PLAN REVIEW
9. VARIANCE MAY BE REQUIRED TO SATISFY MECOSTA COUNTY SETBACK ZONING
6. NEW UTILITY EASEMENTS SHALL BE PROVIDED, AS NEEDED, TO ACCOMODATE REQUIREMENTS. NOT FOR CONSTRUCTION
CLIENT 03/01/24------ Scale AS SHOWN BARR PROJECT No.
BID -------
Project Office:

BARR ENGINEERING CO. Date 03/01/2024


EV BATTERY
BATTERY
BATTERY PLANT
MATERIALS DEVELOPMENT
MATERIALS
PLANT PLANT
DEVELOPMENT 22541027.07
CONSTRUCTION -------
PERMIT -------
3033 ORCHARD VISTA DR SE
SUITE 200
Drawn JMD3 GOTION, INC. MECOSTA COUNTY,
BIG RAPIDS, MI
MICHIGAN CLIENT PROJECT No.
Checked OTC
------- GRAND RAPIDS, MI 49546
A JMD3 OTC JJB 03/01/2024SITE PLAN REVIEW Corporate Headquarters: SITE AND GRADING PLAN
RELEASED A B C 0 1 2 3 Minneapolis, Minnesota
Ph: 1-616-512-7000 Designed RSC DWG. No. REV. No.
NO. BY CHK. APP. DATE REVISION DESCRIPTION TO/FOR DATE RELEASED Ph: 1-800-632-2277
Fax: (951) 832-2601
www.barr.com
Approved JJB
OVERALL C-201 A