You are on page 1of 2

Instalación hidráulica Agua Fría

Tramo Q máx. (Lps) Coef. Sim. Q máx. prob. (Lps) Diámetro (m) Longitud (m) Accesorios Long. Equiv. (m) Long. T (m) hf (mca)
A-B 1.05 0.4082 0.4286 0.0268 3 TSL (1.7), Ve (0.2), TPD (0.4), E (0.3) 2.6 5.6 0.1228
B-C 0.85 0.4082 0.3470 0.0268 2.5 TSB (1.7) 1.7 4.2 0.0603
C-D 0.51 0.5 0.2550 0.0268 13.5 C90 (0.7), TSB (1.7) 2.4 15.9 0.1234
D-E 0.34 0.7071 0.2404 0.0206 0.5 TPD (0.4) 0.4 0.9 0.0231
E - Re 0.17 1 0.1700 0.0206 1.5 2C90 (1.2), TSL (1.4), Ve (0.1) 2.7 4.2 0.0540
E-F 0.17 1 0.1700 0.0206 1 TSL (1.4) 1.4 2.4 0.0309
F - Wc1 0.1 1 0.1000 0.0206 2.5 C90 (0.6) 0.6 3.1 0.0138
F - Lv1 0.07 1 0.0700 0.0206 3.4 2C90 (1.2) 1.2 4.6 0.0100
D-G 0.17 1 0.1700 0.0268 5 TPD (0.5) 0.5 5.5 0.0190
G - Wc2 0.1 1 0.1000 0.0144 2.5 C90 (0.4) 0.4 2.9 0.0773
G - Lv2 0.07 1 0.0700 0.0144 4.4 3C90 (1.2) 1.2 5.6 0.0731
C-H 0.34 1 0.3400 0.0268 1.5 TPD (0.5) 0.5 2 0.0276
H - Ld 0.2 1 0.2000 0.0268 1.95 C90 (0.7) 0.7 2.65 0.0127
H - Fr 0.14 1 0.1400 0.0206 6.4 3C90(1.8) 1.8 8.2 0.0715

La norma establece una serie de presiones minimas para muebles hidráulicos, enunciadas a continuación:
Mueble Presión (mca) Utilizando la fórmula CD = CDT - (H mueble + hf mueble)
Wc 3.5 Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249 2.6164
Lv 3.5 Para Wc1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756 3.6257
Ld 3.5 Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884 3.5295
Re 2.1 Para Wc2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639 3.5972
Fr 3.5 Para Lv2 3.5014
Para Ld 3.2266
Para Fr 3.6178

Por lo tanto los muebles conectados a tuberias de AC cumplen con las presiones mínimas, por ende con la Norma.

3.1766

Instalación hidráulica Agua Caliente


Tramo Q máx. (Lps) Coef. Sim. Q máx. prob. (Lps) Diámetro (m) Longitud (m) Accesorios Long. Equiv. (m) Long. T (m) hf (mca)
A-B 1.05 0.4082 0.4286 0.0268 3 2TSL (3.4), Ve (0.2), E (0.3) 3.9 6.9 0.1513
B - Cal 0.25 0.5774 0.1444 0.0206 0.95 2C90 (1.2) 1.2 2.15 0.0199
Cal - C 0.21 0.5774 0.1213 0.0206 2.45 2C90(1.2), TSL (1.7), TSB (1.7) 4.6 7.05 0.0461
C-D 0.14 0.7071 0.0990 0.0206 13.5 C90 (0.6), TSB (1.7) 2.3 15.8 0.0689
D-E 0.11 1 0.1100 0.0144 0.5 TPD (0.3) 0.3 0.8 0.0258
E - Re 0.08 1 0.0800 0.0144 1.5 2C90 (0.8), TSL (1.3), Ve (0.1) 2.2 3.7 0.0631
E - Lv1 0.03 1 0.0300 0.0144 4.4 2C90 (0.8) 0.8 5.2 0.0125
D - Lv2 0.03 1 0.0300 0.0144 9.4 3C90 (1.2) 1.2 10.6 0.0254
C - Fr 0.07 1 0.0700 0.0144 7.9 3C90 (1.2) 1.2 9.1 0.1188

La norma establece una serie de presiones minimas para muebles hidráulicos, enunciadas a continuación:
Mueble Presión (mca) Utilizando la fórmula CD = CDT - (H mueble + hf mueble)
Wc 3.5 Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249
Lv 3.5 Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756
Ld 3.5 Para Lv2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884
Re 2.1 Para Fr: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639
Fr 3.5
Ya que los muebles conectados a tuberias de AC cumplen con las presiones mínimas, la instalación hidráulica cumple con la Norma.