You are on page 1of 16

HUNTERSVILLE, NORTH CAROLINA USA

— EFFECTIVE SEPTEMBER 1, 2004 —

Green
EPA

Lights
A L L Y
USE OF THIS LOGO DOES NOT
IMPLY EPA ENDORSEMENT

JUNE 2007• E-mail: nsi@nsiindustries.com • Fax: 800.841.5566 • Phone toll free: 1.800.321.5847
www.nsiindustries.com

A DIVISION OF NSi INDUSTRIES, LLC


TORK PHOTOCONTROLS: OVER 80 YEARS OF
EXPERIENCE PACKED INTO EVERY SINGLE BOX.
EXCELLENCE THAT THE FIELD HAS COME TO EXPECT FROM TORK, SINCE 1922.
ONE SIMPLE GOAL: EXTRAORDINARY PRODUCTS COMBINED WITH EXTRAOR-
DINARY SERVICE, MAKING YOUR LIFE IN THE FIELD EASIER, EVERY DAY.
TORK Photoelectric Controls are designed and manufactured with components which adhere to the high-
est industry standards. Trained personnel and in-process quality control procedures ensure that every unit
meets our strictest quality standards.

CHOICE OF TOUGH ENCLOSURES CHOICE OF MOUNTING


PHOTOCELLS ORIENTATION
Models are available in fixed position
Cadmium
or 180˚ swivel.
sulphide, epoxy
sealed cells are
available in 1⁄2”
and 1”
All conduit and flush mounted models utilize
either die-cast zinc or genuine Lexan® materials.
All turn-lock models utilize high impact UV stabi-
lized polypropylene materials.

DEPENDABLE AMBIENT LIGHT TURN-LOCKS MEET ANSI C136.10


READINGS All models meet the current Color-Coded Dome
Built-in time delay prevents false switching due to ANSI requirements for lock- Grey 105-130VAC
light from vehicles, lightning, etc. Instant response ing-type prongs and color Maroon 208-277VAC
is available in turn-lock models. coded voltage designations.
Blue 105-285VAC
Locking prongs are solid
brass. Yellow 480VAC

TABLE OF CONTENTS
2100 Series Zinc Die Cast Conduit Mounting . . . . . . . 1
2000 Series Lexan® Fixed Conduit Mounting . . . . . . . . 2
2001 Series Lexan® Swivel Conduit Mounting . . . . . . . 3
2020 Series Lexan® Pencil Swivel Conduit Mounting . . 4 2100 2000
3000 Series Lexan® Flush Mounting . . . . . . . . . . . . . . 5
5000S Series Turn-Lock Mounting Standard Surge 3000
Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5000M Series Turn-Lock Mounting MOV Surge 2020 2005A/7A/8A 2001
Arrestor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2005A/2007A/2008A Series Turn-Lock Mounting . . . 7 5000M
5737TZ Tork Phototimer Plus . . . . . . . . . . . . . . . . . . . . 8
5737TM Tork Phototimer . . . . . . . . . . . . . . . . . . . . . . 9 5000S 5200 5737
5717T Tork Phototimer . . . . . . . . . . . . . . . . . . . . . . . . 9 RECEPTACLES/
ACCESSORIES
5200 Series Utility Grade Electronic Photocontrols . . . 10
6000 Watt Contactors with Photocontrol . . . . . . . . . . 11
5500 Shorting Cap . . . . . . . . . . . . . . . . . . . . . . . . . 12
CONTACTORS 5500
Receptacles and Turn-Lock Accessories . . . . . . . . . . . 12
Alphanumeric Index and Terms of Sale . . . . . . . . . . . 13 Lexan® is a registered trademark of the General Electric Co.
2100 SERIES
SPECIFICATION GRADE
1⁄2” CONDUIT MOUNTING

IN DIE CAST ZINC


APPLICATIONS
• Parking Lot Lighting Control
• Building Perimeter Lighting Control
• Outdoor Sign Lights

FEATURES
• Heavy Duty die cast zinc housing and base.
• Gasketed for maximum weather protection
• Delay of up to two minutes prevents false
switching due to light from vehicles or
lightning, etc.
SPECIFICATIONS MOUNTING
• Turn ON/Turn OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, BRACKET
without the slide in position.ON/OFF adjustment is easily made
by moving a light level selector. No tools required. 2"
DIMENSIONS
1-7/8" 3-1/4"
2" 1-7/8"
1-7/8" 3-1/4"
• Cell: Cadmium sulphide, epoxy coated, 1” diameter. 2" 3-1/4"
• Contacts: Remain closed between dusk and dawn. (The unit fails
in the ON position). 3" 3" 4-1/2"
4-1/2"
3"
• Lead Wires: Three color coded, minimum 6” wire 4-1/2"

leads, #16AWG, rated for 105˚C.


• Power Consumption: Averages under 1 watt. 3/4" B-BRACKET FOR
• Temperature Range: -40˚ to +140˚F (-40˚ to +60˚C) 3/4"
3/4" B-BRACKET
WALL MOUNTING OFFOR
ALL
1/2" CONDUIT B-BRACKET FOR
FITTING
1/2" CONDUIT WALL
1/2” MOUNTING
MOUNTING OF
CONDUIT
WALL
MODELS
OF ALL
ALL
1/2" CONDUIT PART #73866 MODELS
FITTING
FITTING 1/2” CONDUIT
1/2” CONDUIT MODELS
PART
PART#73866
#73866

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST

2101 60012 120 SPST 2000W 1800VA


2104 60013 208-277 SPST 2000W 1800VA
2105* 60030 120 SPST 3000W 3000VA
2107 60031 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2105 HAS A POLYCARBONATE ENCLOSURE, 1⁄2 ” CELL, 1 YEAR WARRANTY. NOT UL OR CSA.

WIRING DIAGRAMS

SPECIFICATION WRITER’S GUIDE


Photocontrol enclosure shall be constructed of die cast zinc, gasketed for weather protection. Cell shall be cadmium sulphide, epoxy coated, one inch diameter. Unit shall
have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40°to +140°F. Unit to
be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105°C. Photocontrol shall have a fixed base for mounting through 7⁄8 inch opening or
1
⁄2 inch K.O. Furnish and install TORK Model 2101, 120VAC, (Model 2104 208-277VAC), (Model 2107, 120/277VAC)

1
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2000
1
SERIES
⁄2” CONDUIT MOUNTING FIXED
POSITION, LEXAN® HOUSING WITH
WEATHERPROOF SEALANT
APPLICATIONS SPECIFICATIONS
• Flood Lamp Control • TURN ON/TURN OFF:
• Patio Lamp Control Turn ON is 1 to 5fc
• Decorative Lighting Control Turn OFF is 3 to 15fc, without the slide in position.
ON/OFF adjustment is easily made by moving a light
FEATURES level selector. No tools required.
• All Lexan® enclosure is impact and vandal resistant • CELL: Cadmium sulphide, epoxy coated, 1⁄2” diameter.
• Translucent Lexan® Dome prolongs cell life by further • CONTACTS: Remain closed between dusk and dawn.
screening out ultraviolet rays. Dome and base are (The unit fails in the ON position).
ultrasonically welded for maximum strength. • LEAD WIRES: Three color coded, minimum 6”
• Delay of up to two minutes prevents wire leads, #16AWG, rated for 105˚C.
false switching due to light from vehicles or lightning, etc. • POWER CONSUMPTION: Averages under 1watt.
• TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C)

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST

2000 60017 120 SPST 2000W 1800VA


2000C 60317 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2000-2 60018 208-277 SPST 2000W 1800VA
2000-7* 62013 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2000-7 HAS A CADMIUM SULPHIDE, 1” EPOXY CELL.

DIMENSIONS WIRING DIAGRAMS


1-5/8"

Move Slide for Earlier


or Later Turn ON
2-3/4"

Black Line Red Lamp



MOUNT
White Neutral
• • nut and
neoprene

AT ANY
3/4" washer
(to be
provided

ANGLE
by the
MOUNTING installer)

BRACKET 1/2" nipple


junction box
8" 3-1/4" Move Slide for Earlier
/8" 3-1/4" or Later Turn ON

4-1/2"
4-1/2"
(Black) Line (Red) Lamp
L1 •240V (White)
L2 • •
For 277VAC:
B-BRACKET FOR
B-BRACKET
WALL MOUNTING OFFOR
ALL
L1 - Line
WALL
1/2” MOUNTING
CONDUIT MODELSOF ALL L2 - Neutral
PART #73866
1/2” CONDUIT MODELS
PART #73866
SPECIFICATION WRITER’S GUIDE
Photocontrol enclosure shall be constructed of Lexan® material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall
be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 1⁄2 inch diameter. Unit shall have a slide for earlier or later turn ON.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40°to +140°F. Unit to be provided
with three color coded, minimum six inch wire leads, #16 AWG, rated for 105°C. Photocontrol shall have a fixed base for mounting through 7⁄8
inch opening or 1⁄2 inch K.O. Furnish and install TORK Model 2000, 120VAC, (Model 2002, 208-277VAC), (Model 2007, 120/277VAC)

2
A DIVISION OF NSi INDUSTRIES, LLC
2001
1
SERIES
⁄2” CONDUIT MOUNTING, 180˚ SWIVEL, LEXAN® HOUSING

APPLICATIONS SPECIFICATIONS
• TURN ON/TURN OFF:
• Flood Lamp Control
Turn ON is 1 to 5fc
• Patio Lamp Control Turn OFF is 3 to 15fc, without the slide in position.
• Decorative Lighting Control ON/OFF adjustment is easily made by moving a light level
selector. No tools required.
FEATURES • CELL: Cadmium sulphide, epoxy coated, 1⁄2” diameter.
• All Lexan® enclosure is impact and vandal resistant • CONTACTS: Remain closed between dusk and dawn. (The unit fails
in the ON position).
• Translucent Lexan® Dome prolongs cell life by further
• LEAD WIRES: Three color coded, minimum 6” wire
screening out ultraviolet rays. Dome and base are
leads, #16AWG, rated for 105˚C.
ultrasonically welded for maximum strength.
• POWER CONSUMPTION: Averages under 1
• Delay of up to two minutes prevents watt.
false switching due to light • TEMPERATURE RANGE: -40˚ to +140˚F (-
from vehicles or lightning, etc. 40˚ to +60˚C)

180˚
SWIVEL

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST

2001 60015 120 SPST 2000W 1800VA


2001C 60315 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2002 60016 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET

DIMENSIONS MOUNTING WIRING DIAGRAMS


BRACKET
1-5/8"
Move Slide for Earlier
2" 1-7/8" 3-1/4" or Later Turn ON
2" 1-7/8" 3-1/4"

Black Line Red Lamp


3" 3" 3-3/4"
4-1/2"
4-1/2"
• White Neutral
• •

3/4" B-BRACKET FOR


3/4" B-BRACKET
WALL MOUNTING OFFOR
ALL
1/2" CONDUIT
FITTING 3/4" WALL
1/2” MOUNTING
CONDUIT MODELSOF ALL
1/2" CONDUIT
1/2”PART #73866 MODELS
CONDUIT
FITTING
PART #73866 Move Slide for Earlier
or Later Turn ON

(Black) Line (Red) Lamp For 277VAC:


L1 •240V (White)
L1 - Line
L2 • • L2 - Neutral

SPECIFICATION WRITER’S GUIDE


Photocontrol enclosure shall be constructed of Lexan® material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall be ultrasonically welded.
Cell shall be cadmium sulphide, epoxy coated, 1⁄2 inch diameter. Unit shall have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON
position. Photocontrol must withstand temperatures of -40°to +140°F. Unit to be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for
105°C. Photocontrol shall have a 180˚ swivel base for mounting through 7⁄8 inch opening or 1⁄2 inch K.O. Furnish and install TORK Model 2001, 120VAC, (Model 2002, 208-
277VAC).

Lexan® is a registered trademark of the General Electric Co. 3


JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2020
1
SERIES
⁄2” CONDUIT MOUNTING, 180˚ SWIVEL, LEXAN® HOUSING

180˚
APPLICATIONS

SWIVEL
• Flood & Patio Lamp Control
• Decorative Lighting Control

“PENCIL”
• Ideal for applications where it is essential to aim the
photocell in an exact direction to sense natural light
but avoid artificial light.
FEATURES
• All Lexan® enclosure is impact and vandal resistant,
cover and base are ultrasonically welded for
maximum strength.
• Delay of up to two minutes prevents false switching
due to light from vehicles or lightning, etc.
DIMENSIONS MOUNTING
SPECIFICATIONS BRACKET
• TURN ON/TURN OFF: Turn ON is 1 to 5fc 1-1/4"D
Turn OFF is 3 to 15fc
2" 1-7/8" 3-1/4"
• CELL: Cadmium sulphide, epoxy coated, 1⁄2” diameter. 2" 1-7/8" 3-1/4"
• CONTACTS: Normally closed.
(The unit fails in the ON position).
3" 3" 4-1/8"
• LEAD WIRES: Three color coded, minimum 6” wire leads, 4-1/2"
4-1/2"
MAX.
#16AWG, rated for 105˚C.
• POWER CONSUMPTION: Averages under 1 watt.
• TEMPERATURE RANGE: -40˚ to +140˚F 3/4" B-BRACKET FOR
(-40˚ to +60˚C) 3/4"
1/2" CONDUIT 3/4" B-BRACKET
WALL MOUNTING OFFOR
ALL
FITTING
1/2" CONDUIT WALL
1/2” MOUNTING
CONDUIT MODELSOF ALL
PART #73866
1/2” CONDUIT MODELS
1-5/8"D
FITTING
PART #73866

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
120V
2021 60024 120 SPST
MODELS 2000W 1800VA
2022 60025 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
Line (Black) (Red) Lamp
•Neutral (White)
• •
WIRING DIAGRAMS

120V 208-277V
MODELS MODELS

Line (Black) (Red) Lamp Line (Black) (Red) Lamp


•Neutral L1

(White)
• • 240V
Neutral (White)
L2 • •
For 277VAC
208-277V L1 - Line
MODELS L2 - Neutral

SPECIFICATION
Line WRITER’S GUIDE(Red)
(Black) Lamp
L1

Photocontrol enclosure shall be constructed of Lexan® material. Cover and base shall be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 1⁄2 inch diameter.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40°to +140°F. Unit to be provided with three color coded, minimum six
240V
inch wire leads, #16 AWG, rated for 105°C. Photocontrol shall have a fixed base for mounting through 7⁄8 inch opening or 1⁄2 inch K.O. Photocontrol shall have a 180˚ swivel
base for mountingNeutral (White)
through 7⁄8 inch opening or 1⁄2 inch K.O. Furnish and install TORK Model 2021, 120VAC, (Model 2022, 208-277VAC).
L2 • •
For 277VAC
L1 - Line
L2 - Neutral
4 Lexan® is a registered trademark of the General Electric Co.
A DIVISION OF NSi INDUSTRIES, LLC
3000 SERIES
FLUSH MOUNTING, LEXAN® HOUSING
APPLICATIONS SPECIFICATIONS
• Pole Lantern Control • TURN ON/TURN OFF:
• Lawn Light Control Turn ON is 1 to 5fc,
Turn OFF is 3 to 15fc
• Walkway Lighting Control • CELL: Cadmium sulphide, epoxy coated, 1⁄2” diameter.
• CONTACTS: Normally closed. (The unit fails in the ON position).
FEATURES • LEAD WIRES: Three color coded, minimum 6” wire leads,
• Control housing is weather-resistant molded Lexan® #16AWG, rated for 105˚C.
with ultrasonically welded seams. • POWER CONSUMPTION: Averages under 1watt.
• Delay of up to two minutes prevents false switching • TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C)
11
due to momentary flashes of light. • MOUNTING: MODEL 3000: flush mounting through ⁄16” hole in
3 3
post lantern or lighting fixture. ⁄8” NPT, Stem ⁄4” long.
Gasket and nut supplied. MODEL 3010: flush mounting into
standard, raintight junction box. Includes plate and gasket to fit
FS type outdoor junction box.

DIMENSIONS WIRING DIAGRAM

2"

LAMP
3/4"

1"
LINE BLK RED
120 VAC WHITE
5/8"
O.D. NEUT.

3/4"

1-1/2"

WITH
GASKET!
MODEL 3010

FLUSH
MOUNTING FOR
WEATHERPROOF
JUNCTION BOX

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ TUNGSTEN BALLAST

3000 60020 120 1500W 1200VA


3000C 60320 SAME AS ABOVE, IN CLAMSHELL PACKAGE
3002 60019 208-277 1500W 1200VA
3006 CSA ONLY 60026 347 1500W 1200VA
3010 60021 120 1500W 1200VA
3010C 60321 SAME AS ABOVE, IN CLAMSHELL PACKAGE

SPECIFICATION WRITER’S GUIDE


Photocontrol enclosure shall be constructed of Lexan® material with ultrasonically welded seams. Cell shall be cadmium sulphide, epoxy coated, 1⁄2 inch diameter. Contacts
shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40°to +140°F. Unit to be provided with three color coded, minimum six
inch wire leads, #16 AWG, rated for 105°C.
1. Photocontrol shall be capable of flush mounting. Furnish and install TORK Model 3000, 120VAC, (Model 3002, 208-277VAC).
2. Photocontrol shall be provided with a metal plate and gasket for mounting to a weatherproof junction box. Furnish and install TORK Model 3010 (120VAC).

Lexan® is a registered trademark of the General Electric Co. 5


JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
5000S SERIES 5000M SERIES
DELAYED RESPONSE DELAYED RESPONSE
TURN-LOCK MOUNTING UTILITY GRADE TURN-LOCK MOUNTING
STANDARD GAP TYPE SURGE ARRESTOR MOV SURGE ARRESTOR
APPLICATIONS
• Street, Highway and other luminaries equipped with locking type receptacles.
5000M where most stringent surge protection is needed.
FEATURES
• Meets stringent utility standards for street and highway lighting
• Complies with ANSI C136.10 and EEI NEMA standards.
• Delayed response prevents false switching due to light from vehicles or
lightning, etc.

SPECIFICATIONS
• MOUNTING: Units and locking-type prongs meet requirements of
ANSI C136.10.
• PHOTOCELL: Cadmium Sulphide, epoxy coated.
• ENCLOSURE: Polypropylene, UV Stabilized, permanent color with • LOCKING PRONGS: Solid brass for maximum corrosion
UV resistant clear acrylic window. Provides high impact, resistance and electrical dependability.
flammability resistance and electrically safe operation. • SURGE ARRESTOR: S SERIES: Open type expulsion design,
• COLOR CODED DOMES: Meet ANSI designations as follows: 2.5KVspark over minimum 5000 follow-through capacity (except
Grey: 105-130VAC Model5007S which has 255 joules MOV.
Maroon: 208-277VAC • SURGE ARRESTOR: M SERIES: 255 joule MOV (metal oxide
Blue: 105-285VAC varistor) exceeds ANSI and NEMA requirements.
Yellow: 480VAC • TURN-ON/TURN-OFF: Turn-ON is 1 to 3 fc. Turn-OFF to
• RELAY: Bi-metal provides positive snap action switching, reducing Turn-ON ratio is 5 max.
bounce and prolonging contact life. • TEMPERATURE RANGE: -40˚ to +140˚F (-40˚ to +60˚C).

DIMENSIONS AND WIRING DIAGRAMS

1 11/16" N L1
2"
Line
(Black) Load (Red)
Receptacle Surface
105 to 285 volt
Neutral Load single phase grounded
(White) supplies and loads
3"

CATALOG UPC VOLTAGE RATING CELL


NO CODE 50-60HZ COLOR TUNGSTEN BALLAST SIZE
5001S 61001 105-130 GREY 1200W 1800VA 1”
5004S 61002 208-277 MAROON 2080-2770W 2080-2770VA 1”
5007S* 61004 105-130/208-285 BLUE 1200/2850W 1800/2850VA 1
⁄2”
not UL
or CSA 5008S 61040 480 YELLOW 1000W 1800VA 1”
5021S 61007 105-130 GREY 1200W 1800VA 1⁄2”

5024S 61008 208-277 MAROON 2080-2770W 2080-2770VA 1


⁄2”
CSA
only 5026S 61044 347 GREEN 1000W 1800VA 1⁄2”

5001M 61012 105-130 GREY 1200W 1800VA 1”


5004M 61013 208-277 MAROON 2080-2770W 2080-2770VA 1”
5007S* 61004 105-130/208-285 BLUE 1200/2850W 1800/2850VA 1⁄2”
not UL
or CSA 5008M 61017 480 YELLOW 1000W 1800VA 1”
5021M 61015 105-130 GREY 1200W 1800VA 1⁄2”
5024M 61016 208-277 MAROON 2080-2770W 2080-2770VA 1⁄2”
CSA
only 5026M 61045 347 GREEN 1000W 1800VA 1
⁄2”
5500 61130 SHORTING CAP
*5007S has MOV surge arrestor

SPECIFICATION WRITER’S GUIDE


5000S SERIES: Furnish and install a time delay photocontrol meets all requirements of ANSI C136.10. Locking type prongs are to be solid brass. Snap action switch to
ensure a minimum contact life of 3600 operations. Cell shall be cadmium sulphide, epoxy coated. Surge arrestor shall be open type expulsion, capable of withstanding
2.5KV spark over with 5000A follow through capacity. Enclosure must be ANSI color coded, high impact, UV stabilized polypropylene and contain a UV stabilized and
absorbing acrylic window. Base must be high impact polycarbonate material with cross linked polyethylene gasket. Unit must provide a load rating of 1000W tungsten,
1800 VA ballast. Furnish and install Tork Model 5_ _ _ S.
5000M SERIES: Furnish and install a time delay photocontrol meets all requirements of ANSI C136.10. Locking type prongs are to be solid brass. Snap action switch to
ensure a minimum contact life of 3600 operations. Cell shall be cadmium sulphide, epoxy coated. Surge protection is to be provided using a 255 joule MOV. Enclosure
must be ANSI color coded, high impact, UV stabilized polypropylene and contain a UV stabilized and absorbing acrylic window. Base must be high impact polycarbonate
material with cross linked polyethylene gasket. Unit must provide a load rating of 1000W tungsten, 1800 VA ballast. Furnish and install Tork Model 5_ _ _M.

6 Lexan® is a registered trademark of the General Electric Co.


A DIVISION OF NSi INDUSTRIES, LLC
2005A/2007A/2008A SERIES
QUICK RESPONSE
TURN-LOCK MOUNTING
APPLICATIONS
• Street, Highway and other luminaries equipped
with locking type receptacles where instant
response is required.
FEATURES
• Meets stringent utility standards for street and
highway lighting
• Complies with ANSI C136.10 and EEI NEMA
standards.

SPECIFICATIONS
• MOUNTING: Units and locking-type prongs meet requirements of ANSI
C136.10.
• PHOTOCELL: Cadmium Sulphide.
• ENCLOSURE: Polypropylene, UV Stabilized, permanent color with UV resistant clear acrylic window. Provides high
impact, flammability resistance and electrically safe operation.
• COLOR CODED DOMES: Meet ANSI designations as follows:
Grey: 105-130VAC
Blue: 105-285VAC
Yellow: 480VAC
• RELAY: Positive snap action switching, reducing bounce and prolonging contact life.
• LOCKING PRONGS: Solid brass for maximum corrosion resistance and electrical dependability.
• 360 joules MOV exceeds NEMA and ANSI requirements.
• TURN-ON/TURN-OFF: Turn-ON is 1 to 3 fc. Turn-OFF to Turn-ON ratio is 3 average.
• TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).

DIMENSIONS WIRING DIAGRAMS

1 7/8"
2-3/16" N L1
Line
(Black) Load (Red)
Receptacle Surface
105 to 285 volt
Neutral Load single phase grounded
(White) supplies and loads
3-3/16"

CATALOG UPC VOLTAGE RATING


NO CODE 50-60HZ COLOR TUNGSTEN BALLAST

2005A 62012 105-130 GREY 1000W 1800VA


2007A 62013 105-285 BLUE 1000W 1800VA
2008A 62014 400-550 YELLOW 1000W 1800VA

SPECIFICATION WRITER’S GUIDE


Furnish and install an instant response type photocontrol which meets all requirements of ANSI C136.10. Locking type prongs are to be solid brass. Relay is to provide positive
snap action switching to ensure a minimum contact life of 5000 operations. Surge protection is to be provided using a 360 joules metal oxide varsitor. Enclosure must be ANSI
color coded, high impact, UV stabilized polypropylene and contain a UV stabilized and absorbing acrylic window. Base must be high impact ABS with a cross linked polyethyl-
ene gasket. Unit must provide a load rating of 1000W tungsten, 1800 VA ballast. Unit must fail in the ON position. Furnish and install Tork Model 2005A (2007A, 2008A).

7
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
DUSK ON
MIDNIGHT OFF
5737TZ TORK PHOTOTIMER PLUS: EARLY MORNING ON
ON AT DUSK, OFF AT MIDNIGHT, DAWN OFF
ON EARLY MORNING, OFF AT DAWN
AM

FITS ORDINARY TURN-LOCK


ESSOR
PHOTOCONTROL SOCKET, MICROPROC

OFFERING TOTAL FLEXIBILITY OFF TIME On TIME

AND MAXIMUM Midnight


Offset
After
Midnight
-0.5 0 +0.5 5 6H 7

ENERGY SAVINGS! -1 H +1 H 4 8
-1.5 +1.5 3 9
-2H 2H 2H 10H

EASY RETROFIT: NO RE-WIRING!


Midnight Early Morning
Adjustable Adjustable
APPLICATIONS/EXAMPLES OFF Time ON Time

• Office building wants parking lights ON at dusk, and OFF SPECIFICATIONS


at 11pm with ON at 5am for reopening and OFF at dawn. • PLUGS INTO STANDARD TURN-LOCK RECEPTACLE
• ALL UNITS MEET OR EXCEED ANSI C136.10
• Restaurant wants signs to turn ON at dusk but OFF at • TIMER: Microprocessor tracks the dusk and dawn times for 24 hours
midnight when no one around to see the signs; area and automatically sets its internal calendar to turn off at midnight
becomes active again before dawn. during all seasons. Automatically adjusts for Daylight Savings Time.
• Billboard needs to be lit at dusk but OFF at midnight • POTENTIOMETER #1: Allows user to adjust OFF time during the
due to lack of traffic which picks up again at 5am. night. OFF time can be set for up to two hours before (for extra
• Landscape and yard lighting need to be lit at dusk but energy savings) or up to two hours after midnight to customize for
OFF at midnight when no one is around and ON again various longitudes to acheive exact midnight turn OFF; or to stagger
for early morning illumination. a group of lights to go OFF at different times during the night.
• POTENTIOMETER #2: Allows user to set number of hours after
midnight (from 2-10 hours after midnight) that lights should turn
TURNS ON LIKE A PHOTOCONTROL, OFF AND back ON. This is used for areas which become active again
ON LIKE A TIME SWITCH, AND OFF LIKE A before dawn.
PHOTOCONTROL! • LIGHT SENSOR: Silicon photosensor.
• DC RELAY: Provides chatter free operation. Normally closed.
FEATURES:
• VOLTAGE RANGE: 105-305VAC
• Microprocessor tracks the dusk and dawn times as the vary • LOAD RATING: 1000W Tungsten, 1800 VA Ballast.
with the seasons and automatically determines midnight. • SURGE PROTECTION: MOV (metal oxide varistor) 360 joules.
NO PROGRAMMING REQUIRED! • PRONGS: Solid brass for maximum corrosion resistance
• OFF time during the night is user adjustable for specific and electrical conductivity.
needs such as extra energy savings or to customize for • ENCLOSURE: UV Stabilized, ANSI color coded polypropylene
various longitudes. dome.
• Early morning ON time is also user adjustable for • WINDOW: UV Stabilized clear acrylic.
providing predawn lighting • BASE: ABS
• GASKET: Cross-linked polypropylene.
• Built in Daylight Savings Time correction.
• TURN ON/TURN OFF: Turn ON at dusk is 5.0 foot candle +/- 0.5
• Automatically “re-learns” and resets after power outage, OFF/ON ratio is 1.5:1 average.
eliminating costly maintenance. • Time Delay ON/OFF: Instant ON, 3-5 seconds OFF.
• FAIL ON: For safety reasons.
SPECIFICATION WRITER’S GUIDE • TEMPERATURE RANGE: -40˚ to +158˚F (-40˚ to +70˚C).
Furnish and install an electronic, instant response type phototimer which meets
all requirements of ANSIC136.10. Unit must turn ON at dusk and OFF at mid-
night, back ON before dawn, and OFF at sunrise. Unit must automatically cor- DIMENSIONS AND WIRING
rect for daylight savings time. Two potentiometers are to be provided. One 5737TZ, 5737TM AND 5700 SERIES
potentiometer must allow for field adjustment for longitude corrections or for
midnight offset of +/- 2 hours. The other potentiometer must allow user to set 120 or
number of hours after middle of the night that lights turn back on (AM burn). 277V
Locking type prongs are to be solid brass. Relay is to provide positive snap
N L1
action switching to assure a minimum contact life of 5000 operations. Surge 2"
2 3/16" Line
protection is to be provided using a metal oxide varistor of 360 joules. (Black) Load (Red)
Enclosure must be ANSI color coded, high impact, UV stabilized polypropylene Neutral Load
Receptacle Surface
and contain a UV resistant clear acrylic window. Base must be ABS with a (White)
cross linked polyethylene gasket. Unit must provide a load rating of 1000 watt
105-305 VAC
tungsten, 1800 VA ballast. Unit must fail in the ON position. Furnish and install 3 1/8" single phase grounded supplies and loads
TORK Model 5737TZ.
FOR 240V, N=L2, L1=L1

CAT. UPC VOLTAGE RATING LIGHT


NO CODE DESCRIPTION 50-60HZ TUNGSTEN BALLAST SENSOR

5737TZ 62010 PHOTOTIMER PLUS 105-305 1000W 1800VA SILICON PHOTOSENSOR

8
A DIVISION OF NSi INDUSTRIES, LLC
5737TM TORK PHOTOTIMER: ON AT DUSK, OFF AT MIDNIGHT
FITS ORDINARY TURN-LOCK PHOTOCONTROL SOCKET, OFFERING FAR
DUSK GREATER ENERGY SAVINGS! EASY RETROFIT: NO RE-WIRING!
ON
AM

MIDNIGHT
ESSO R APPLICATIONS/EXAMPLES:
MICROPROC

OFF
• Office building wants parking lights ON at dusk, and OFF at 11pm.
OFF TIME
Midnight • Billboard needs to be lit at dusk but OFF at midnight due to lack of traffic.
Offset
-0.5 0 +0.5
-1 H +1 H
-1.5
-2H
+1.5
2H TURNS ON LIKE A PHOTOCONTROL, AND OFF LIKE A TIME SWITCH!
FEATURES: • Microprocessor tracks the dusk and dawn times as they vary with the seasons and
Midnight Adjustable
automatically determines midnight. NO PROGRAMMING REQUIRED!
OFF Time
• OFF time during the night is user adjustable for specific needs such as extra energy savings or
to customize for various longitudes.
• Built in Daylight Savings Time correction.
• Automatically “re-learns” and resets after power outage, eliminating costly maintenance.

CAT. UPC VOLTAGE RATING LIGHT


NO CODE DESCRIPTION 50-60HZ TUNGSTEN BALLAST SENSOR

5737TM 62009 PHOTOTIMER: ON AT DUSK, OFF AT MIDNIGHT 105-130 1000W 1800VA SILICON PHOTOSENSOR

SPECIFICATION WRITER’S GUIDE


Furnish and install an electronic, instant response type phototimer which meets all requirements of ANSIC136.10. Unit must turn ON at dusk and OFF at midnight. Unit must
automatically correct for daylight saving time. Potentiometer must be provided for field adjustment for longitude corrections or midnight offset of +/- 2 hours. Locking type
prongs are to be solid brass. Relay is to provide positive snap action switching to assure a minimum contact life of 5000 operations. Surge protection is to be provided
using a metal oxide varistor of 360 joules. Enclosure must be ANSI color coded, high impact, UV stabilized polypropylene and contain a UV resistant clear acrylic window.
Base must be ABS with a cross linked polyethylene gasket. Unit must provide a load rating of 1000 watt tungsten, 1800 VA ballast. Unit must fail in
the ON position. Furnish and install TORK Model 5737TM.

SPECIFICATIONS AND WIRING FOR 5737TM AND 5700 SERIES ARE SIMILAR TO 5737TZ

5717T SERIES NIGHT ENERGY SAVER: ON AT DUSK, OFF AFTER


FIXED DURATION.

DUSK
FITS ORDINARY TURN-LOCK PHOTOCONTROL SOCKET, OFFERING FAR GREATER

ON
AM
NIGHT ENERGY SAVINGS! EASY RETROFIT: NO RE-WIRING!
APPLICATIONS/EXAMPLES:
FIXED DURATION
OFF
MICROPROC
ESSOR • Office building wants parking lights ON at dusk, but has no need for them all night
• Billboard needs to be lit at dusk but lack of traffic during the night would make lighting a
waste of energy.
TURNS ON LIKE A PHOTOCONTROL, AND OFF LIKE A TIME SWITCH!
FEATURES: • Microprocessor turns light off during the night after a predetermined time. Extra OFF time during the night
provides for additional energy savings.
• Factory preset models in 4, 5, 6, 7, or 8 hours.NO PROGRAMMING REQUIRED!
• Turn ON is 1.0 footcandle +/- 0.5. Turn OFF is after selected hours.

CAT. UPC VOLTAGE RATING LIGHT


NO CODE DESCRIPTION 50-60HZ TUNGSTEN BALLAST SENSOR

5717-T4 62004 PHOTOTIMER: ON AT DUSK, OFF AFTER 4 HOURS 105-305 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5717-T5 62005 PHOTOTIMER: ON AT DUSK, OFF AFTER 5 HOURS 105-305 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5717-T6 62006 PHOTOTIMER: ON AT DUSK, OFF AFTER 6 HOURS 105-305 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5717-T7 62007 PHOTOTIMER: ON AT DUSK, OFF AFTER 7 HOURS 105-305 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5717-T8 62008 PHOTOTIMER: ON AT DUSK, OFF AFTER 8 HOURS 105-305 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL

SPECIFICATION WRITER’S GUIDE


Furnish and install an electronic, instant response type phototimer which meets all requirements of ANSIC136.10. Unit must turn ON at dusk and OFF _ _ hours after
turnON. Locking type prongs are to be solid brass. Relay is to provide positive snap action switching to assure a minimum contact life of 5000 operations. Surge protection
is to be provided using a 255 joules MOV (metal oxide varistor). Enclosure must be ANSI color coded, high impact, UV stabilized polypropylene and contain a UV resistant
clear acrylic window. Base must be phenolic with a cross linked polyethylene gasket. Unit must provide a load rating of 1000 watt tungsten, 1800 VA ballast. Unit must fail
in the ON position. Furnish and install TORK Model 5717-T_.

9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
5200 SERIES
UTILITY GRADE ELECTRONIC PHOTOCONTROLS WITH FAIL ON MODE
APPLICATIONS SPECIFICATIONS
• For use where the extreme accuracy and reliability • STANDARD LIGHT SENSORS:
of an electronic photocontrol is required and in the 1. Cadmium Sulphide photocell: responds to the light spectrum near
event of failure, lights should stay ON for safety to that of a human eye. Resists effects of moisture and airborne
reasons. contaminants. (A Hermetically sealed cadmium sulphide photocell is
available – consult our factory!)
FEATURES: 2. Silicon Photosensor: assures drift-free operation, turning on and
off at the same light level consistently throughout the life of the unit.
• Meets or exceeds ANSI C136.10 standards.
• DC RELAY: Positive snap action switching, reducing bounce and
• DC operated relay provides chatter free operation. prolonging contact life.
• High joule capacity MOV • CONTACT LIFE: 5000 operations minimum
• Minimum power dissipation across the light sensor • NOMINAL VOLTAGES: 120V, 208/277V, 120/277V, 50-60Hz.
• Stable turn ON and turn OFF levels regardless in For other voltages contact factory.
changes in the ambient temperature. • LOAD RATING: 1000W Tungsten, 1800 VA Ballast.
• Lower total life cycle costs. • PRONGS: Solid brass for maximum corrosion resistance
• Delayed turn OFF of 3-5 seconds reduces false switching and electrical conductivity.
from vehicles, lighting or other stray light and is • SURGE PROTECTION: MOV (metal oxide varistor) 360 joules.
consistent over the operating temperature range. • ENCLOSURE: UV Stabilized, ANSI color coded, high impact
• Enclosure provides high impact and flammability polypropylene dome.
resistance as well as UV protection. • WINDOW: High impact, UV Stabilized acrylic.
• Fail ON mode. • BASE: High impact ABS
• Rugged and reliable. • GASKET: Cross-linked polypropylene.
• Color coded per ANSI • TURN ON/TURN OFF: Turn ON is 1.5 foot candle +/- 0.2 (other
light levels are available). OFF/ON ratio is 1.5:1 average. For
other ratios, consult our factory.
• Time Delay ON: Instant (others optional).
• Time Delay OFF: 3-5 seconds, standard (others optional).
• FAIL ON: For safety reasons.
• OPERATING TEMPERATURE: -40˚ to +158˚F (-40˚ to +70˚C).
• POWER CONSUMPTION: 1.0 watt average @ 120V
• WARRANTY: 5 years

DIMENSIONS WIRING DIAGRAM


105 to 305 volt single phase
grounded supplies and loads.
N L1 N L1
2" Line
2 3/16" Line
(Black) (Black) Load (Red) Load (Red)

Receptacle Surface Neutral Load 105 to 285 volt


(White)
Neutral Load single phase grounded
(White) supplies and loads
105-305 VAC
3 1/8" single phase grounded supplies and loads

CAT. UPC TURN VOLTAGE RATING LIGHT


NO CODE ON* 50-60HZ TUNGSTEN BALLAST SENSOR

5211 78882 1.5 fc 105-130V 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5217 78884 1.5 fc 105-305V 1000W 1800VA CADMIUM SULFIDE (CDS) PHOTOCELL
5231 78885 1.5 fc 105-130V 1000W 1800VA SILICON PHOTOSENSOR
5237 78886 1.5 fc 105-305V 1000W 1800VA SILICON PHOTOSENSOR
* FOR OTHER OPTIONS, CONSULT FACTORY AT 888-500-4598.

SPECIFICATION WRITER’S GUIDE


Furnish and install an electronic instant response type photocontrol which meets all requirements of ANSI C136.10. Locking type prongs are to be solid brass. Relay is to provide
positive snap action switching to ensure a minimum contact life of 5000 operations. Surge protection is to be provided using a 360 joules metal oxide varsitor. Enclosure must be
ANSI color coded, high impact, UV stabilized polypropylene and contain a UV stabilized and absorbing acrylic window. Base must be high impact ABS with a cross linked poly-
ethylene gasket. Unit must provide a load rating of 1000W tungsten, 1800 VA ballast. Unit must fail in the ON position. Furnish and install Tork Model 52 _ _.

10
A DIVISION OF NSi INDUSTRIES, LLC
5400 SERIES
6000 WATT CONTACTORS WITH TURN-LOCK
PHOTOCONTROL
FOR STREET LIGHTING

APPLICATIONS
• For controlling all lighting loads in excess of the capacity of the
photoelectric control contacts

SPECIFICATIONS
• ENCLOSURE: Outdoor NEMA Type 3R. Beige enamel finish. Two 1⁄2”–3⁄4” combination
KO in bottom.
• RECEPTACLE: 3-prong turn-lock meets the requirements of EEI NEMA. Adjustable
over full 360˚ for proper photoelectric control orientation.
• PHOTOCONTROL: Appropriate model as indicated in the table below – is included.
• POWER CONSUMPTION: Maximum 3 watts during daylight, watts at night.

CAT. UPC INCLUDES PHOTO VOLTAGE CONTACT RATING


NO CODE CONTROL MODEL 50-60HZ PER POLE SWITCH

5403 60009 5021S 105-130 3000 WATTS DPST


5404 60010 5024S 208-240 3000 WATTS DPST
5404-3 60011 5024S 277 3000 WATTS DPST
5420 60014 5021S 105-130 1000 WATTS SPDT

WIRING DIAGRAMS

120 VOLT CIRCUIT 277 VOLT CIRCUIT 208 or 240 VOLT


MODEL MODEL CIRCUIT
5403 WHT BLK RED WHT BLK RED 5404-3 MODEL 5404
WHT BLK RED
WHT BLK RED

LOAD LOAD LOAD LOAD


LOAD
LOAD LOAD
WHT WHT
WHT
WHT
H H
120V 120V H
N N H
277V 208V or 240V
H 120V N H

120V 2-WIRE SYSTEM 120V/240V 3-WIRE SYSTEM 277V/480V 4-WIRE SYSTEM 208V/240V 4-WIRE SYSTEM

CASE Add photoelectric control dimensions


120 VOLT CIRCUIT 2" high x 3" diameter
MODEL WHT
DIMENSIONS
5420 RED
BLK

RED LOAD 1
(184mm)
7-1/4"

N BLUE LOAD 2
WHT 4-1/2"
H 120V 3-13/32"
BLK (114mm) (87mm)

LOAD 1 CLOSES AT DUSK, OPENS AT DAWN


LOAD 2 CLOSES AT DAWN, OPENS AT DUSK

11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
TURN-LOCK PHOTOELECTRIC CONTROL ACCESSORIES
5500
SHORTING CAP
FEATURES:
CAT. UPC
• Provides a convenient and NO CODE DESCRIPTION
economical method of closing
the primary circuit with a NEMA 5500 61130 SHORTING CAP
locking-type receptacle. Durable materials
and gasket provide both long life and materials and gasket
provide both long life and weatherproof protection. For use
with all voltages.

CATALOG NO. 2223 CATALOG NO. 2224


Receptacle, 120-480V, color coded #14 Receptacle, 120-480V, color coded
leads, neoprene gasket, two mounting #14 leads, mounting bracket and one
screws. mounting screw.

CATALOG NO. 2421


CAT. UPC
Receptacle, 120-480V, color coded #12 NO CODE DESCRIPTION
leads, plastic housing, lock nut (with 1⁄2”
NPT), and mounting bracket. 2223 61025 RECEPTACLE WITH NEOPRENE GASKET
2224 61026 RECEPTACLE WITH MOUNTING BRACKET
2421 61021 RECEPTACLE WITH PLASTIC HOUSING
AND MOUNTING BRACKET

TORK PHOTOTIMER PLUS


THE MOST FLEXIBLE PHOTOTIMER FOR MAXIMUM ENERGY
SAVINGS AND ALL ON/OFF
ON/OFF NEEDS!
5737TZ DUSK ON
MIDNIGHT OFF
EARLY MORNING ON
The TORK Phototimer Plus is the most flexible photocontrol ever, operating

DAWN OFF
like a photocontrol AND a time switch! Ideal for retrofit without expensive
rewiring. The unit turns the load ON at sunset and can be preset to turn the load
OFF up to two hours before or two hours after midnight. It can also be set to turn
the load back ON from two to ten hours after midnight and OFF at dawn.

No programming is required, the microprocessor tracks dusk and dawn times and
automatically determines midnight, and corrects for Daylight Savings Time. It even
re-learns and resets itself after a power outage, so that no maintenance is ever
needed. See page 8 for more information on 5737TZ!

12
A DIVISION OF NSi INDUSTRIES, LLC
ALPHANUMERIC INDEX TERMS OF SALE
CATALOG TORK VENDOR NUMBER: 786261
SERIES PAGE
2000 . . . . . . . . . . . . . . . . . .2 1. Prices are F.O.B. our plant.
2. Prices do not include any sales tax.
2001 . . . . . . . . . . . . . . . . . .3
3. Freight charges will be prepaid on all orders $250.00 and over
2005A,2007A,2008A . . . . . .7
shipping within continental USA using standard shipping meth-
2021, 2022 . . . . . . . . . . . . .4 ods and service.
2100 . . . . . . . . . . . . . . . . . .1 4. Minimum order – $100.00.
2223, 2224 . . . . . . . . . . . .12 5. Claims for shortage, erroneous charges or price corrections shall
2421 . . . . . . . . . . . . . . . . .12 be deemed waived unless made in writing, delivered to NSi
3000 . . . . . . . . . . . . . . . . . .5 within 30 days of invoice.
6. Terms of payment – 2% 10th prox. net 25th following.
3010 . . . . . . . . . . . . . . . . . .5
7. Warranties – NSi guarantees all products to be free of defects in
5000M . . . . . . . . . . . . . . . . .6 material and workmanship for a period of 1 year from date of
5000S . . . . . . . . . . . . . . . . .6 sale. Any claims for defective material must be agreed to in
5200 . . . . . . . . . . . . . . . . .10 writing by NSi. Defective material will be replaced on an F.O.B.
5400 . . . . . . . . . . . . . . . . .11 – our factory basis. NSi disclaims the implied warranty of fitness
5500 . . . . . . . . . . . . . . . . .12 for a particular application.
5717T . . . . . . . . . . . . . . . . .9
5737TM . . . . . . . . . . . . . . . .9
OTHER PRODUCTS AVAILABLE
NSi can provide many other products for special applications which
5737TZ . . . . . . . . . . . . . . . .8
are not listed in this catalog. If you require an item which you do
not find listed, please contact us. We would be pleased to provide a
quotation upon receipt of a drawing or a sample.

GUARANTEE
It is our goal to provide extraordinary products and service on a
daily basis. If our products or service do not meet with your satis-
faction, please let us know immediately and we promise to make
every reasonable effort to remedy the situation.

13
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
TORK TECHNICAL INFORMATION: 888.500.4598
REQUEST YOUR COMPLETE SET OF TORK CATALOGS TODAY!

NSI INDUSTRIES, LLC • USA • 800-321-5847 • FAX 800-841-5566 • www.nsiindustries.com

You might also like