You are on page 1of 26

AirScale 5G gNB AMIA

RAN Nokia Solution


Installation & Commissioning Overview

GS COO - Global Delivery Readiness


Didier TANGUY
February 2020

1 © Nokia 2015 Nokia Internal Use


System Module
AMIA Hardware
Description
AirScale System Module - AMIA Configuration
for a 2G-3G-4G-5G Product

SRAN 5G

3 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Rear Side AMIA : Fan & Shunt
• Fans with changeable airflow direction (by rotating fans).
Default direction is front-to-back.

• DC-Bridge.

If DC Powering Then the DC-bridge from backplane And required


is

Power Option 1 • Is already connected by default • Only 1 DC Primary


(to feed all the subracks) Power connection

Power Option 2 • Must be removed • 2 independent DC


(to feed only by half subracks) Power connection

Power Option 3 • Is already connected by default • 1 DC Primary Power


(to feed all the subracks with connection +
redundancy) • 1 DC Secondary
Power connection
Power Option #1 Power Option #2 Power Option #3

4 © 2017 Nokia Nokia Internal Use


AirScale System Module Indoor (AMIA)
Front view Rear view

Nokia Product Code:


473098A

The AirScale Subrack (AMIA) main properties:


• IP20 ingress protected
Property Value
• Operating temperature range: from -5°C to +55°C
Height (3U) 128.5 mm (5.1 in) • Can be installed inside a 19-inch wide rack or cabinet
• Can be stacked on top of each other.
Depth 400 mm (15.7 in)

Width (19’’) 447 mm (17.6 in) The AirScale Subrack AMIA includes:
• Subrack frame
Empty (w/o blind covers) 5.1 kg (11.2 lb)
• Backplane for high bandwidth interconnect between
Weight with dummy panels 6.8 kg (15 lb) • AirScale Common and
• AirScale Capacity plug-in units
with all units 23.9 kg (52.7 lb)
• Fans with changeable airflow direction (by rotating fans).
• Default direction is front-to-back.
5 © 2017 Nokia Nokia Internal Use • Blind-units to prevent cooling airflow leakage
System Module
AMIA Installation
AirScale System Module - AMIA Installing and Cabling Manual
Installing AMIA

7 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Installing cable holders

8 © 2017 Nokia Nokia Internal Use


AMIA Installation

SRAN 5G

Nokia Internal Use 9


System Module Hardware and
Physical connectivity

10 © 2017 Nokia <Document ID: change ID in footer or remove> <Change information classification in footer>
gNB-DU in 5G18A:
AirScale System Module Indoor • Maximal configuration: 1x ASIK + 1 ABIL
ASIK, ABIL, AMIA gNB-DU in 5G19:
• Minimal configuration: 1x ASIK + 1 ABIL
ASIK & ABIL high capacity introduction • Maximal configuration: 1x ASIK + 3 ABIL

AirScale SM Indoor Description


consist of
1 AirScale Subrack • Common with 2G/3G/4G/5G
AMIA (473098A) • 8 Slots for plug-in units
• AMIA provides 3 slots per ASIK to host plug-in units.
= • The actual max of used ABIL slots depend on the system release ABIL
1…6 AirScale Capacity • L1 support
ABIL (474020A) • 8x8 100MHz MIMO depending on configurations
AMIA
+ • 2x QSFP+: 8x9.8 Gbps for CPRI fronthaul
1…2 AirScale Common • Local OAM, sync, transport and L2 support
ASIK (474021A) • 2x SFP+: for 10 GE Backhaul interface
• Sync IN and OUT, External Alarms and Controls, LMT
• DC 48 V input
Characteristics Description
Installation options 19 inch, pole and wall, outdoor cabinet

Dimensions 19” 3 U H 128 x W 447 x D 400 [mm] ASIK


Weight 10.1 kg minimum (1 ASIK + 1 ABIL + 1 AMIA)
23.5 kg maximum (2 ASIK + 6 ABIL + 1 AMIA)

Ingress protection IP20 Confidential


11 © 2017 Nokia
Operational temperature range -5 °C to 55 °C
AirScale 5G system module plug-in units front view and external interfaces
ASIK 474021A:
AirScale Common Plug-in Unit version K

ASIK functions:
• L2 non-Real Time processing,
• L3 Transport interfacing (Ethernet)
• Local O&M
• Synchronization
• Power feed
RESET SIN SERVICE
DC EAC SOUT LMP SEI EIF-1 EIF-2

Port # of interfaces Connector Description Note


DC in 1 DC terminal 48V DC input To connect the DC power supply
EAC 1 HDMI External alarm & control, 6 alarms, 6 alarms/ctrls To connect the External Alarms
SIN 1 HDMI Synchronization input, GNSS interface To connect the External Synchronization (GPS, GNSS..)
SOUT 1 HDMI Synchronization output To connect the Distribution of Synchronisation
LMP 1 RJ45 Local management port, 1G Ethernet. Debug port used to connect a PC directly to the ASIK board and
access to BTS Rescue console (in factory mode), to 5G BTS Element
Manager (after Sw is installed) or to SSH console.
EIF 2 SFP28 Backhaul/Higher Layer Fronthaul interface. Interfaces:
Up to 25GE per port. • Cloud gNB : F1 fronthaul interface between RAC and RAU carrying
Support for Sync.E and IEEE1588. the F1 CP, UP and OAM flows
• Classical gNB : X2 , S1 backhaul and OAM interfaces
Rates: Supports 1 GE, 10 GE and 25 GE rates
• 5G18 : 1 GE, 10 GE
• 5G19 : 1 GE, 10 GE, 25 GE
SEI12 1
© 2017 Nokia QSFP+ System Extension Interface, 4 x 10GE Support 4 x 10G Ethernet and 40G Ethernet
AirScale 5G system module plug-in units front view and external interfaces

ASIK 474021A:
AirScale Common Plug-in Unit version K

ASIK functions:
• L2 non-Real Time processing,
• L3 Transport interfacing (Ethernet)
• Local O&M
• Synchronization
• Power feed
RESET SIN SERVICE
DC EAC SOUT LMP SEI EIF-1 EIF-2

Topic # of interfaces Description Note


RESET 1 Plug-in unit RESET, with several Pressing this button results in a reset of the ASIK.
scenarios Thus the ASIK reboots into the same active software as before resetting the ASIK.
It causes a service outage.
• If pressed > 5 seconds, commissioning data is cleared but the security parameters are kept.
The BTS must be recommissioned
• If pressed < 5 seconds, commissioning data remain intact.
SERVICE 1 Service button, recovery reset Used to erase the commissioning data and to restore the ASIK to the default factory mode
(FDSW Factory Delivered Software).
This may be needed if the software is corrupted.
LEDs 7 Visual indication of status Refer to document 5GRAN Rel 5G19, Operating Documentation, Nokia Airscale System
Module Product description to get the LED status

13 © 2017 Nokia
AirScale 5G system module capacity plug-in unit front view and external interfaces
ABIL 474020A:
AirScale Capacity Plug-in Unit version L

ABIL
S-RFIF1 S-RFIF2 Q-RFIF1 Q-RFIF2
SFP+ / SFP+ / QSFP+ / QSFP+ / S-RF1 Q-RF1
SFP28 SFP28 QSFP28 QSFP28 S-RF2 Q-RF2

# of ABIL
Signal Connector Description
Interfaces
RF-n (QSFP) / 2 QSFP+/28 Low Latency Fronthaul connection to CPRI or Ethernet radios.
Q-RFIFn ABIL shall support CPRI10.1376Gbps and 24.33024Gbps rate + 10GE and 25GE Ethernet protocols.
Optical CPRI10.1 to RF up to 10km (HW capability).
One QSFP connector has four CPRI/Ethernet links.
Remark: Only QSFP+ (4x CPRI 9.8 Gbps per each port)
RF-n (SFP) / 2 SFP+/SFP28 Low Latency Fronthaul connection to Ethernet radios.
S-RFIFn Support for 10GE and 25GE protocols
Remark: eCPRI 10/25 GE per each port available in 5G19
LEDs 5 Visual indication of status

ABIL functions:
• L1 + L2 RT processing in gNB-DU
• RF interfaces to RU. Up to 2x 3rd generation radios
14 © 2017 Nokia
AirScale 5G Modules

ASIK Common Board

ABIL Capacity Board

15 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Installing plug-in units in AMIA

Installing ASIK and ABIL in a minimum configuration

Open the extractors on both sides


16 © 2017 Nokia Nokia Internal Use
AirScale System Module - AMIA Installing and Cabling Manual
Installing Common and Capacity boards in a minimum configuration

Close the extractors on both sides


17 © 2017 Nokia Nokia Internal Use
AirScale System Module - AMIA Installing and Cabling Manual
Installing Common and Capacity boards in a minimum configuration

18 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Installing Common and Capacity boards in target configuration

19 © 2017 Nokia Nokia Internal Use


Remove the filler panels according to the expected config.
AirScale System Module - AMIA Installing and Cabling Manual
Installing Common and Capacity boards in a maximum configuration

20 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Preparing optical interfaces ASIK / ABIL

SFP marked blue and QSFP marked green in the picture

21 © 2017 Nokia Nokia Internal Use


System Module
Power Supply,
Sync GPS & EAC Cabling
AirScale System Module - AMIA Installing and Cabling Manual
Connecting the grounding cable

23 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Connecting the DC power cables in ASIA-ASIK
2. Lift the latch of the DC power cable input.
3. Insert stripped end of the DC power cable into the DC power cable input
4. Close the latch of the DC power input so that the DC power cable is firmly secured.

24 © 2017 Nokia Nokia Internal Use


AirScale System Module - AMIA Installing and Cabling Manual
Connecting synchronization, EAC, and LMP cables to ASIA/ASIK

RJ-45 (LMP interface)


HDMI Sync Out (SOUT interface)
HDMI Sync In (SIN interface) (GPS)
HDMI EAC (EAC interface)
25 © 2017 Nokia Nokia Internal Use
THANK YOU

26 © Nokia 2015 Nokia Internal Use

You might also like