CALIBRATION CERTIFICATE [Namo and Address of Customer [Page Number Tort ULR Number [0250723000007 62F IMangal Electrical Industries Pvt. Ltd, [Certificate Number [2502/0151/08 [Job Request Number & Date [202315109 & 31/01/2023, Piot No. E-40 to E-46 & E-46A, [Date of Receipt foavoar2023 [Shree Khatu Shyam Ji Industrial Area, [Calibration Dato joavozr2023 Reengus, Sikar, Rajasthan - 332 404 [Recommended due on ary (as per customer request) (Certificate Issue Date josrozr2023 Description & Identification of UUC Name [Measuring Tape Condition on Receipt oK Maker [Calibration Model Freemans cr | SENG Performed At oat [Calibration Gaanve Range 0.5000 mm iD. No. |MEIPLIMT-01 arena, Dimension ce Tmm [Location _[— Environment Condition Calibration Procedure Number [Temperature / Humidity [20 = °C /50 + 10%RH ES/SOPINI2T based on OIML R-36-1 and NABL-120-1(A) Dols of Standard Master Equipment Used: Nomencature See. Range | Cerificate No. | Vali [ Callvated By Wessurbg Beale 8 Tape] ase o-tooomm | 22000041361 | zarcarzoze | NABL Cer No, Co-2105 MECHANICAL CALIBRATION - DIMENSION CALIBRATION RESULTS Woninal Value on USTs] Avg Value on Standard in tror Expanded Uncaranty mm rom mm a 200 200065 D088 00 400.188 “0158 oo 600265 “0295 ooo soot 031 1000 1000.54 “054 121 pm mete 2o0 200724 “07% sooo soon a82 “0392 «oa oons21 “0921 5000 500.058 1054 "Rorrarks= 1. The reported expanded uncertainty is at coverage factor k=2 which corresponds fo @ coverage probability of approximately 99% fora normal astnbution 2 Certificates shal nt be roproduced except infu, 3. Results relaie only to the tems calibrated. 4 Readings are taken without adjustment and readin without The written epproval of Excellent Services 198 are average of 3 sets of readings. 5. All standard equipments used for callration are traceable to National Standards. 6 UG: Unt Under Caloation. Engineer-Calibration Vee ingh (Format No: QR/M/05, Rev. 00), CALIBRATION CERTIFICATE a a RASS oT CUSTOM Page Nor Ta ee name aS TOTOROTTERF tanga lotic industios Pt Lic Gerfeate Hana 0001510 ob Request nurtor& Date —|p0euo1s 108 OTROS Plot No. E-40 to E-46 & E-46A, |Date of Receipt }os/02/2023 Shree Kat Shyam J indus Area, Garaton Dao osarozs Foongu, Sar ojstan 32 40a Recomm Sa nT as pr customer request) Gate ame Da SaaS Description & Identification of UUC Sanionon tame [gta Frequency Meter ect ox aie airaton ake lerown arn. _[oEs-2oaneora0ans earn ta ange 70-1000 #2 Do eatraton Frequenay ne THE [osaton Tram Coan Gaibraon Provedare Wambo? eprare Ray Zs £0 TSETEU AH | ESSOPETIT based on15 12a o}.2010 NRSC ADEA DatalsofStandard/Mestr Equipment Used Tomei Sr Nurbor | — Carats Number [Vaal —— Galbated By Tih Product Calter aeere01 | Fuereiososoce-coot [oeean25 | WABL Cot. No. C5 ELECTHOTECHNICAL CAUBRATION CALIBRATION RESULTS Galbraon Points 00, 0, 00H ‘Average Value on Stanardin | Average Vale ov UUGT® | —Emarin Sepandad Uncen Hz Hz Hz + (%) 100, 99 a 0.58 500 40 1 oa 080 os 2 008 — 1 Tm wpe pun! wets set orp fact ed wth cempach cvtign peROY of ppm 2. Catior sal ro tepid ecptn tet Th mite pele Eclat Sanne 2 hosts ton too fons ented {Renna ant ener od doe a wget Sst fra 4 Alone pat dr caiireten eae hare! Suna EnginorCatraton Autionzed 6 Ratah@&h Kr. Singh Sarva) Brijesh Kuma\Singh ae ‘UR |= (Technical Manager) (Format No.: QR/ET/O1 Rev. 00) CALIBRATION CERTIFICATE is aR Ce age Robe Tar OLR Norber cc aSeTOOOOTTEAE hang lets ndusie Pvt. ceriteate ora snr eb Requot Nona Dio —osanTernTEOTETERD Plt Ns. E4010 £488 £404, at of Rese ea sre Kt Shyam inti clbston Dt osca Rena, Sar, Rajan 252408 Recorinended a3 (as per customer request) panielanas cet sve Dao [S523 Descipon &lencaion of UC Name Digital Ampere Meter AC Condition on Receipt OK Mako! —[Soeider eee ake (RRS ESCTT Sno, anezaasea Calan Poorest tab ange [o-sooa es: 64) ano, [= Calibrator Parenter Curent ce OA [maior == Enaronont Condon Gallatin Procedre Numer Tampa TH 52°C S5~TORA | —ESISOPETEY tsa on Tapa 9) 2070 and NGL Ont of Standard/ ster Equipment Used aT SeMambor | Coniesto ta.“ ] Vay aE Mae Pewuacatvar | __sooraor | FHOVET00082327" | cgaanzs | WABL Cet No. cOaTEG LECTROTECRIGAL Ca HRATION cAUpRATION RESULTS rg agai on Sanaa Ear SSRI TRAY Temal Value | Roqured | Wessured value | Conveid hs = | vate) (hoa) ‘009 1 ‘eos — sons “082 O18 2000 3 som | amar 087 ons eone 8 cor | anza 123 os amore: 1. The reported expanded uncertainty is at coverage factor k=2 which corresponds to @ coverage probability of approximately 95% fora normal cstrbution 2. Cattiicates shal not be reproduced excoptin ful, without The writen approval of Excelent Serves. 3. Results relate ony tothe tems caltrate. 4. Readings are takon without adjustment and readings are avorage ofS sets of readings. 5. All standard equipmonts used for calibration are traceable to National Standards. 6. Affced the Excolont Calibration Sticker’Seal onthe Instrument 7. WUC: Unit Under Calitration. Engineer-Calibration cs (Format No.: QR/ET/O1 Rev. 0) CALIBRATION CERTIFICATE Name and Address of Customer Page Number ror [ULR Number [eczss72s000001765F IMangal Electrical Industries Pvt. Ltd. [Cerificate Number 230210181112 [dob Requost Number & Date [2028/0151/12 & 31/01/2003 Plot No, E-40 to E-48 & E-48A, Date of Receipt [osvoa/e023 [Shree Khatu Shyam Ji Industral Area, [Calibration Date fosroare0as R = jue on feengus, Sikar, Rajasthan - 332 404 Recommended due iaaeceeda (as per customer request) [Cerificate Issue Date [osroara025 Description & Identification of UUC Name Digital Ampere Meter AC Condition on Receipt 0K Maker |Schneider Electrie7 Meet eee erie. (Sr.No. [aetezatais2 Calibration Performed At Lab Range }0-600A (FSD: 6A) id. No. a Calibration Parameter ‘Current Lc. 041A [Location |- Environment Condition Calibration Procedure Number [Temperature 7Humicity 254°C /38- 76V0RH ES/SOPIETIOI based on 1S:1248(part-0):2019 and NABL 120-4 Detalls of Standard / Master Equipment Used Nomenclature Sr Number Cerificate No. Validity Calibrated By Mult Product Calibrator 3967801 FUGIET/08062022- |” gayoeaoza NABL Gert. No. CC-2739 ‘ELECTRO-TECHNIGAL CALIBRATION CALIBRATION RESULTS vue “Avg. value on Standard Error Expanded Uncertainty NominalValue| Required | Measured Value | — Converted (A) Value (A) (A) (Ato A) ” zm) 700.0 1 1.0048 100.48 “0.48 015 300.0 3 3.0091 300.91 091 018 600.0 6 sore 601.18 1.18 018 Romarks:- 1. The reported expanded uncertainty is at coverage actor ke2 which corresponds toa coverage probably of aporoximatoly 9556 fora normal distribution 2. Cotcaes shall not be reproduced excep in ul, without The wrlten approval of Excelent Services. 5, Results relate only tothe items calibrated. 4. Readings are takon without adjustment and readings are average of 6 sets of readings. 5. Al standard equipments used for callration are traceable Natona Standard 6. Afixed the Excelent Calibration Sticke/Seal onthe Intumant 7. WG: Unit Under Caran. Engineer-Calibration i Authorized Signa Se) ae Rate she Kr. Singh (Blsaieuk 5) Brijesh Kuma Singh (Format No. QR/ET/O1 Re. 00) AN AS Re (Technical Makiager) Coser CALIBRATION CERTIFICATE Rami and rane of Cuatomr Page Naor Ta OLR Nurer oxsSTASOOOOOTERF Mangal Eocesl industries Pt, Li, eriteate Narbar oasis lob Request Nuber& Daa [2021713 ESTOTROES lone. 4010 £48 848A, Bate ef Recent panaroz3 Stee Kat Sys J dual Ae, caibraton Date psarnzs Reena, Ska, Rojan 22404 Recommended don |(as per customer request) josvociades Gest ese Oste [D507 2025 Description & ientiicaion of UC heme [isa Ampere itor AG Candin on Rei ox ata” —Sehraaer ocr key [Rehr EIGCH=T yo, aetozaer7aa Calbraton Peon A a Range [06004 80:64) fa.No. [= Calraton Parner Curent ke OFA locaton [= Enviroment Gondlion Callbraton Procedure Number FemperatrerRumiaiy [2524°C/35-7SRRA_| — ESSOPIETAT based on1S12spa o} 2070 ad NAGL DET Details of Standard | Master Equipment Used Tomenciare Se Wuber —[-—Coresteo. [Vai Caibama ey Mt Product Caterer | __sesreor | FUOIL08082022TGepgmeas | NABL Cot No. COZTEO LECTRO-TECIRIGAL CATERATION CALIBRATION RESULTS WE Tiga on Standard a Expanded Urea Woninal aloo] Roqued | Wansured Valo | Convertod (A) Value (A) A) (Ato A) “a =O ‘000 1 7.088 10088 “088 76 2000 a a.cone 20o8e 08 os e000 8 ote eo1.02 02 os Remarks 1. The reported expanded uncertainty is at coverage feciork=2 which corresponds to a coverage probabilty of epproximetely 95% fora normal dstrbution 2. Conifcates shal not be reproduced except in ful, without The witen approval of Excellent Services. 3. Resuits relate only tothe items calibrated. 4. Readings are taken without adjustment and readings are average of $ sets of readings. 5. All stndard equipments used for caloraton ere traceable to National Standards. 6. Aired the Excellent Calsation Sticker!Seal on the Insiument 7, WUC: Unit Under Calibration Engineer-Calibration PR: ee ee (Format no. QR/ET/03 Res. 00) Brijesh Kumar\singh (Technical Manager) CALIBRATION CERTIFICATE Ra an ars CT age ber Tar OLR Nabe SG 207TEUOOOOTTF tanga lectialindusties Pt Li carta Nonber soars ib Resunt nba Dale —pOOUOTET 4 T STRESS oto, 4010 £488 484, Bate Reset oanarczs Sie Kat Syam J aust a, cabrton Dats osoartzs eens, Shar, Rajostan 382404 Reconmended doe on (as per customer request) renee ceria ue ba ——SOTAOS Grecian & enifteation of WUE fone [Baar Ape Motor AS Condon on Rca ox iaral —Seneidr ooo? scar [SRRRarEOGCT ye Jotezaraso CaliatonPoomodA tab ange [ston 30: 6a) No. [= Caran Parameter caret ce OA [loeton [= Envronment Condon Calbraton Procedure Number ampere Huma fs 4°01 S5- TERA | ESSOPTETI bated on Spo) 2010 and ABLAZE of Standard Master Equipment Used SEED LA TET Sa Vas Peat Caltrar | _seere0r | FURTETINEOE2022— Tsgcsonzs | NABL Gen No. CO-TH0 ELESTROTECHRICAL CAUBEATION cAUpRaTiON RESULTS WE Tigre on Sana a Eepanaed UnSTA oninalVale | Requved | Weasured Val | Convene im a (A) Value (A) 4A) (Ato A) a 1099 1 7008s 10035 “28s 098 x00 3 aoe | nee 06 o1s eo00 8 eo | _oone0 099 ous Remarks:- 1. The reported expanded uncertainty Isat coverage factor k=2 which coiresponds to @ coverage probabil of approximately 95% for a normal distribution. 2. Cettiicates shall not be reproduced except in ful, without The written approval of Excellent Services. 3. Results relate only tothe items calorated 4. Readings are taken without adjustment and readings are average of 5 sets of readings. 5. All stonderd equipments used for calibration are traceable fo National Standards. 6. Affced the Excellent Calration Sticker’Seal onthe Instrument 7, UG: Unit Under Calbration Engineer-Calibration (Format No. GR/ET/02 Rew. 0) Authorized Stgnat Brijesh Kum (Technical Marlager) CALIBRATION CERTIFICATE [Name and Address of Customer [Page Number [rot [OLR Number [oczss72s000001760F [Mangal Electrical Industries Pvt. Ltd. (Gerificate Number lasozrorsins ob Request Number & Date |2023/0161/16 & S1/01/2020 Plot No. E-40 to E-48 & E-46A, [Date of Receipt losroar2023 [Shree Khatu Shyam Ji Industrial Area, (Calibration Date josroaraozs FReengus, Sikar, Rajasthan - 332 404 Recommended due on fas per customerrequesty _|°%02/2024 (Certificate Issue Date losroara0es Description & Identification of UUC [Condition on Name Digital Volt Meter AC Receipt oK Make! Ty, (Calibration Nake’ |sigmaysop.260|sr.no. Jauvis patemet Al Lab ; = (Calibration jaw Range | 0-80v(FSD: 400) |iD. No ale Voltage Lc OAV [Location == Environment Condition Calibration Procedure Number [Temperature Humidity | 254°C 735- 76%RH ESISOPIETION based on 1S:1248(par-6):2010 and NABL “120-4 Details of Standard / Master Equipment Used: Nomenclature ‘Sr. Number Certificate Number _[ Validity Calibrated By Muli Product Calibrator 3967801 FLIG/ET/08082022-C00T | 9/08/2025 |_NABL Cert. No. CC-2739 ELECTRO-TECHNICAL CALIBRATION CALIBRATION RESULTS WUC “Average on Standard Error Expanded Uncertainty Nominal Value | Required Value | Measured Value | Converted w w £(%) Ww) w) w (Vtow) 10.0 50 50.315 10.08 0.315 -0.08 tz 40.0 200 200.53 40.11 0.53 01 0.23 80.0 400 400.87 80.17 -0.87 0.47 0.46 Remarks:- 1. The reported expanded uncertainty is at coverage factor ke2 which corresponds fo @ coverage probability of approximataly 95% fora normal distribution. 2. Comtfeates shal not be reproduced except in ful, without The writen approval of Excellent Services. 3. Results rolate only to the items calibrated 44. Readings are taken without adjustment and readings are average of sets of readings, 5. All standard equipments. used for caliration are traceable to National Standards. 6, Axed the Excolont Calloation Sticker/Seal onthe Instrument 7. WUC: Unit Under Cainration Engineor-Calibration Authorized: i (Format No: QR/ET/O1 Re. 00) Brijesh Kumar\singh (Technical Marlager) CALIBRATION CERTIFICATE [Name and Address of Customer Page Number iret JOUR Number [eCaseras00000T Ter lMangal Electrical industries Pvt. Lt. Cerifeate Number 2s02016116 [dob Request Number & Date [2020/0151/16 & S1/0T2025, Plot No. €-40 to E45 & E-45A, Date of Receipt loswaroz3 [Shiee Knatu Shyam J industrial Area, (Caibration Date losvoarzozs [Reengus, Skar, Rajasthan - 332 404 Recommended due on (es percustomerrequesty [22/02/2024 (Certiicate Issue Date osa2035 Description & Wentification of UUC [Condition on [Name [Digital insulation Tester Sona oK ake? calioraton Maker |motwane /it-51 sco. Eabraton Lab OaTEIsOOV E Calibration : Range TAI500V& lipo, | MEIPLIDIT-01 [Eatbraton Resistance ce. = Calibration Procedure Number [Temperature Humaiy — [254°C 735-75%RA ESISOPIETIOT based on IS'1248(par-0):2019 and NABL 1294 Details of Standard / Master Equipment Used Nomenclature Sr_Number Certificate Number Valty Calbrated By Standard Megohm Box To0801 ‘CaluiCaL/22-ve/00s —| — 08/06/2028 | NABL Cer. No. CO-Z2T6 Standard Megotm Box 710 corecur7aere22 | 1390272023 _| NABL Cert. No. CC-2287 ELECTRO-TECHNICAL CALIBRATION. SULTS Range Value on Standard “Average Value on UUC Error Expanded Uncertainty +0) 2.069 NO 2.02 Mo “0040 WO 37 @soov 20:21 Ma 20.1 Ma 0221 Ma 37 199,983 ma 199 ma 0.983 Ma 37, 99.98 GO, 8 Ga “0.98 GO 38 @ s000v 487.04 co 498 ca 0.96 Ga 60 1102985 Ta 4102 Ta -0.00885 Ta 60 Romarks:- 1. The reported expanded uncertainty is at coverage factor k=2 which corresponds to a coverage probabiliy of proximately 95% fora narmal aistnbution 2. Cericates shall not be reproduced except in ful, without The writen approval of Excallent Services. 3. Results relate only tothe items calbrated. 44. Readings are taken without adustment and readings are average of 5 sets of readings. 5. All siandard equipments used for callraton are traceable to National Standards, 6, Affxed the Excelent Calibration Sticken/Seal onthe Instrument Enter olor storied (Technical Manager) (Format Na: OR/E1/04 Re. 00) CALIBRATION CERTIFICATE Name and Address of Customer Page Number ra [OLR Number lccaearas00000TTTOF Mangal Electrical Industries Pvt Ltd. Ceniicate number aoaotsin7 Job Request Numbor & Date 20230161717 & STOTRODS Plot No. E-40 to £45 & E-48A, Date of Receipt osvoaz028 Shee Khatu Shyam si Industal Area, Calivation Date osroaa023 Reengus, kar, Rejastnan- 922 404 Recommended due on a (as per customer request) _ [0222 Cerificate Tue Dato [OS7020025 Description & identification of UUC (Condon on Name tal Turn Ratio Meter coed oK Calibration Make! Model stNo. | Performed At ea T78808 Carton Range aoteoes TUM |I0.No, — |MEIPLIOTRM-O1 eeeraen Ratio LC. 0.004 & 0.01 Turn [Location |-—— [Cal. Range. Up to 110 Turn Environment Gondtion Callbration Procedure Number Temperature Homa 252 CT S00RA ESISOPIETT based on 1S:1246(par-0}:20T0 and NABL-T2O Details of Standard / Master Equipment Used Nomensiatre Sr. Number | Cortfeate Number Calibrated By Rats Cairaton Standard C2000L16 ‘cxz2igearei01 | Taoare023 | ~RABL Cert No. CODE ELECTRO-TECHNICAL CALIBRATION CALIBRATION RESULTS Range] — SetValue on Standardin | Average Value on UUG in | Error n | ~ Expanded Unceraialy Tun Tum Ture 4) 0-10.000Tum tt 11.007 0.007 04 @ 72.06 008 oa 0-199, 09Tum “4 4409 0.09 04 110 110.14 014 o4 Remarks:- 1. The reperted expanded uncertainty is at coverage factor k=2 which corresponds to @ coverage probabiliy of approximately 195% for a normal cistibuton 2. Certfcates shall nt be reproduced except in ful, without The writen approval of Excellent Services. 3, Results relate onl to the itome calibrated. 44 Readings are taken without adjustment and readings are average of § sets of readings. 5 All standard equipments used for callration are traceable to National Standards. 6 Affxed the Excellent Calbration Sticker/Sea! onthe Instrument 7. WUC: Unit Under Calibration. Engineer-Calibration (Format to. QR/ET/10 Fe. 00) (Technical Marlager) CALIBRATION CERTIFICATE Name and Address of Customer Page Number rare [ULR Number [oc2ss72s00000T TIF IMangal Electrical Industries Pvt. Ltd. Cerificate Number s020151/18 [Job Request Number & Date _[2029/0161/18 & 317012028 Plot No. £40 to £46 & E-45A, Date of Receipt osrozrz0ze [Shree Khatu Shyam Ji Industrial Area, [Calibration Date osoar0z3 Reengus, Sika, Rajasthan - 332 404 [Recommended due on ebapoae (as per customer request) [Cerificate Issue Date oeroar2025 tion & Mentification of UC Name [Three Phase Power Analyzer Condition on Receipt OK Make? Calibration Performed Maker Yokogawa! W7333E [sco [carD18049e nf Lab fa Calibration] Voltage Gurrent/ Frequency ange: [As Pet, Resatts Hee co Parameter Power / Power Factor CSAs perresurts Cocation [= Environment Condition Gallbration Procedure Number Temporaiwre/Humidty | 25 2 £0735- 76%RH_| ESSOP/ETHS based on 1S:1240 (par-/ 2076 and NABL-T2O-T Details of Standard / Master Equipment Used Nomenclature Sr.No. Certificate Number Valid Calibrated By Three Phase Calibration Soures | EDPVIta09.076 | CalufCAL/a2-0a10s8 | ~Ta/a2/2003 | WABL Cen Ne: CODD "ELECIRO-TECHNICAL CALIBRATION CAUBRATION RESULTS [Ac Wottage @ site Phase Set Value on Standard] Average Value on WUC] Error] Expanded Uncertainty (Vv) (Vy VY) £(%) $3.00 07 DOr 023 R 1 150.00 160.11 On O23 i 300.00 30022 022 023 T 63.00 33.015 DOs 023 Y i 150.00, 150.08, 0.08 0.23, i 300.00 300.18 079 023 1 53.00 e014 Dot 028 8 1 750.00 150.14 0.14 023 i 300.00 SOO A 023 IAC Current @ SoH Phase (A) 4A) 4A) +(%) 7 2.00 Z0008 T0008 023 R i 10.00 10.004 0.004 0.23, iT 20.00 z0.0t2 0012 023 1 2.00 Z00Ts D.00t8 023 y 1 7000 70.007 0.007 025 i 20.00 Boor O01 025 i 200 Z0015, T0015 023 8 i 70.00 70008 0.008 023 i 20.00 20.016 0.016 oy Engineer-Calibration ‘Authorized STypa Ratandphr Kr. Singh (Format Na. QR/E1/03 Rev. 00) (Technical ager) CALIBRATION CERTIFICATE Calibration Date losroz2023 Page Number 2 of 2 pomereoeen lozi0z/2024 |ULR Number 1cc269723000001771F (es per customer request) ‘CALIBRATION RE: Frequency: Frequency ‘Set Value on Standard ‘Avg. Value on UUG Error Expanded Uncertainty (Hz) (Hz) (Hz) £0) 50.00 30.05, 0.03 0.14 Frequency 55.00, 35.04, 0.04 014 60.00 60.05 0.05) 026 Power: Phase Set Value on Standard ‘Avg. Value on UC] Error Expanded Uncertainty Ww (A) | (PF) | (watt) (Watt) (Watt) =(%) T 3.00 | 2.00 | 1.0 | 126.0 126.08 0.08. 0.14 R T 150.00_[_10.00_| 1.0 | 1500.0 1501.73, 173 0.14 TH 300.00_[~20.00_| 1.0 | 6000.0 {007.96 7.96 0.26 T 63.00 | 2.00 [1.0 | 126.0 126.11 011 0.14 Y T 150.00 [10.00 _|_1.0 | 1500.0 1501.85 1.83 0.14 i "300.00 | 20.00 [7.0 | 6000.0 6008.18 8.16 0.26 i 63.00_| 2.00 | 1.0 | 1260 126.12 0.12 0.14 8 W 150.00 | 10.00 _| 4.0 | 16000 7502.62 2.62 0.14 ur 300.00 | 20.00 [1.0 [6000.0 6008.14 9.14 0.26 Power Factor: Phase ‘Set Value on Standard ‘Avg. Value on UUG Error Expanded Uncertainty (PF) (PF) (PF) +(PF) Tag 0.500, 0.5002 0.0002 Oi R tunity 7.0007 7.0003 0.0003. ont lead 0.500) 5004 0.0004 O41 lag 0.500. 0.5000. 0.0000. ont x unity 7,000, 7.0002, (0.0002 ont lead 0.500. 0.5001 0.0007 Ott Tag 0.500. 0.5001 (0.0001 ott 8 ‘unity 7,000 7.0002 .0002 ott Tead 0.500, 7.5003 0003 ort Remarks 1. The reported expanded uncertenty is at coverage factor k=2 which corresponds o a coverage probability of approximately 9596 for normal distribution 2 Corticates shall nat be reproduced except in full without The writen approval of Excellent Services. 3. Results relate ony tothe items calibrated. 4. Readings are taken without adustmant and readings are average of & sets of readings. 5 All standard equipments used for caliration are traceable to National Standards 6 Affixed the Excellent Calbration Sticker/Soa! onthe Instrument 7. WUC: Unit Under Calibration. Engineer-Calibration ‘Authorized anlar: singh (Format No QR/E1/03 Rew. 0) Brijesh Kumay Singh (Technical Maljager) CALIBRATION CERTIFICATE Namo and Address of Customer [Page Number rer [ULR Number [ocass7a300000T TTF IMangal Electrical Industries Pvt. Ltd, (Cerificate Number 23021016119 jiob Request Number & Date _|2029/0151/19 & S1/012023, Pict No, E-40 to E-46 & E-46A, Date of Receipt fosrozreoz3 [Shree Khatu Shyam Ji Industrial Area, [Calbration Date fosrozr2023 IReengus, Sikar, Rajasthan - 332 404 Recommended due on anemia (as per customer request) [Gerifcate Issue Date loaroara025 Description & Identification of UC [Name __ [Transformer Winding Resistance Tester [Condition on Receipt OK Makes Motweane: Sr.No. |A04299115, [Calibration Performed At Lab Model XWRM-10A : Range: As por Results |I0No. [= [Galbration Parameter Resistance Lc. ‘As perResults [Location [— Environment Condition Calibration Procedure Number [Temperature /Humiaity 25 = 40736- TSGRA_| ESISOPIETIOT based on IS:1248\(part-9) - 2079 and NABL 120-4 Details of Standard / Master Equipment Used Nomenclature Sr. Number Cerificate Number | Validity Calibrated By Slandard Resistance Box 238 72783 (2022-2028) | 14/12/2023 | NABL Gert. No. CO-3385 ELECTRO-TECHNICAL CALIBRATION CALIBRATION RESULTS Current | Range | Value on Standard | Average Value on UUC Error Expanded Uncertainty Rango + (%) Bm 700029 mo TOOT mal “BOOTS ma 0.14 toa | 20m 10.0115 ma 10.001 ma 0.00015 ma 014 200m 100.069 ma 100.06 ma 0.008 ma 0.14 20 1.000402 0 1.0003 9000102 0 012 Zone 70.0015 ma TO.0TT ma 0.00965 ma O14 ta | 200m0 100.069 ma 100.04 ma 0.029 ma. ona 20 4.000402 0 4.0002 -0.000202 0 oz 200 10.00104 a 410.000 0 -0.00104 0.12 Zo0me 700.069 mir 100.05 mah 0.019 ma 0.14 tooma | 20 1000402 a 1.0005 0 0.000088 a 0.12 200 10,00104 a 10.002 0 0.00096 0 0.12 2000 92.9949 0 9999.0 0.0049 0 012 Romarks:- 1. The reported expanded uncertainty is at coverage factor k=2 which corresponds to a coverage probabil of approximately 98% for a normal distribution 2. Ceitiicates shal not be reproduced exceptin ful, without The writen approval of Excellent Services. 3. Results relate only tothe items calibrated. 4. Readings are taken without adjustment and readings are avorage of§ sate of readings. 5. All standard equipments used for calibration are traceable to National Stendards. 6. affixed the Exoslient Caliration Sticker / Seal on the instrument 7. WUC: Unit Under Calioration Engineer-Calibration aie og & (Forme No. OR/ET/03 Rev. 00) Authorized: \ Brijesh Kumar\singh (Technical Marlager)

You might also like