Sensor fitting
Manual
IM 12D07K04-01EN-P
3rd edition
2
IM 12D07K04-01EN-P
3
Contents
1. PREFACE........................................................................................................ 4
1.1 Introduction.............................................................................................. 4
1.2 Unpacking and Checking ....................................................................... 4
1.3 Warranty and Service ............................................................................. 4
1.4 Serial number........................................................................................... 5
2. ISC40FF FLOW FITTING............................................................................... 6
2.1 General Specifications............................................................................. 6
2.1.1 Materials................................................................................................ 6
2.1.2 Operating range................................................................................... 6
2.1.3 Shipping details (Without options)..................................................... 6
2.1.4 Process connections............................................................................. 6
2.2 INSTALLATION OF ISC40 SENSOR IN ISC40FF ..................................... 7
2.3 DIMENSIONS............................................................................................ 8
2.4 MODEL CODE ISC40FF FITTING...........................................................10
2.5 SPARE PARTS ISC40FF FITTING.............................................................11
3. ISC40FS FLOW FITTING SUBASSEMBLY................................................... 12
3.1 General Specifications...........................................................................12
3.1.1 Materials..............................................................................................12
3.1.2 Operating range.................................................................................12
3.1.3 Shipping details .................................................................................12
3.1.4 Process connections...........................................................................12
3.2 INSTALLATION OF ISC40 SENSOR IN ISC40FS....................................13
3.3 DIMENSIONS..........................................................................................14
3.4 MODEL CODE ISC40FS FLOW FITTING SUBASSEMBLY......................15
3.5 SPARE PARTS ISC40FS FLOW FITTING SUBASSEMBLY.......................16
4. ISC40FD IMMERSION FITTING................................................................. 17
4.1 General Specifications...........................................................................17
4.1.1 Materials..............................................................................................17
4.1.2 Operating range.................................................................................17
4.1.3 Shipping details .................................................................................17
4.1.4 Process connections...........................................................................17
4.2 INSTALLATION OF ISC40 SENSOR IN ISC40FD...................................18
4.3 DIMENSIONS ISC40FD..........................................................................19
4.4 MODEL CODE ISC40FD .........................................................................21
4.5 SPARE PARTS ISC40FD...........................................................................22
5. CHEMICAL COMPATIBILITY...................................................................... 23
IM 12D07K04-01EN-P
4
1. PREFACE
1.3 Warranty and Service
1.1 Introduction
Yokogawa products and parts are guar-
The ISC40 sensor fitting program for anteed free from defects in workman-
inductive conductivity measurement is ship and material under normal use
designed to meet the most common and service for a period of (typically) 12
installation requirements in terms of months from the date of shipment from
material compatibility, process connec- the manufacturer. Individual sales or-
tions and flow dynamics. The various ganizations can deviate from the typical
installation possibilities are described warranty period, and the conditions of
and illustrated in this manual. sale relating to the original purchase
The following categories of installation order should be consulted. Damage
can be recognised: caused by wear and tear, inadequate
1. Direct mounting of sensors in tank maintenance, corrosion, or by the effects
wall or customer supplied flanges of chemical processes are excluded from
2. Cost effective installation of sensors this warranty coverage. In the event
using process adapters of warranty claim, the defective goods
3. Maintenance friendly installation of should be sent (freight paid) to the
sensors using in-line subassemblies Service Department of the relevant sales
4. Installation in flow chambers for Organization for repair or replacement
measurements in sample streams (at Yokogawa’s discretion).
or bypass loops
5. Installation in immersion fittings The following information must be
for measurement in open tanks or included in the letter accompanying the
channels returned goods:
Within the wide range of process • Model Code and Serial Number.
adapters, subassemblies, flow fittings • Original Purchase Order and Date.
and immersion fittings it is easy to find • Length of time in service and de-
the appropriate installation that fits the scription of the process.
application (a wide choice of materials), • Description of the fault and circum-
the plant installation practice (a wide stances of the failure.
choice of process connections) and the • Process/environmental conditions
maintenance procedures. that may be related to the failure of
the fitting (option)
1.2 Unpacking and Checking • Statement as to whether warranty
or non-warranty service is request-
Upon delivery, unpack the product care-
ed.
fully and inspect it to ensure it was not
• Complete shipping and billing
damaged during shipment. If damage
instructions for return of material,
is found, retain the original packing
plus the name and phone number
materials and then immediately notify
of a contact person that can be
the carrier and the relevant Yokogawa
reached for further information.
sales office. Make sure the Model Code
• Clean Statement
and Serial Number on the fitting are the
Returned goods that have been in
same as on the packing list. Also, check
contact with process fluids must be
any option(s) that were ordered are
decontaminated and disinfected prior
included and correct.
to shipment. Goods should carry a cer-
tificate to this effect, for the health and
safety of our employees. Material Safety
Data sheets must be included for all
components of the process to which the
fitting (options) have been exposed.
IM 12D07K04-01EN-P
5
Example: N3P400123
Year Year
Year Year
code code Month Month code
IM 12D07K04-01EN-P
6
Note (1): If required the ISC40 sensor type -GG and -TG can be supplied with a Viton
gasket K1500AM (ordered as spare part). This gasket may be used with the older
series of ISC40FF fittings. It should be discarded when the sensor is mounted in com-
bination with the ISC40FF type -PA and -FA.
IM 12D07K04-01EN-P
7
Stainless steel
/FF1 PVDF
/FP1 Polypropylene
Stainless
steel
ISC40FF-FA
ISC40FF-PA
/FF2 PVDF
/FP2 Polypropylene
Stainless
steel
72 L
ISC40FF-FA/FF1 L=90.5-96 [3.56-3.78]
ISC40FF-PA/FP1 L=90.5-96 [3.56-3.78]
ISC40FF-FA/FF2 L=79.5-85 [3.13-3.35]
ISC40FF-PA/FP2 L=79.5-85 [3.13-3.35]
/FF3 PVDF
/FP3 Polypropylene
ISC40FF-FA/FF3 L=90.5-96 [3.56-3.78]
ISC40FF-PA/FP3 L=90.5-96 [3.56-3.78]
ISC40FF-FA/FF4 L=79.5-85 [3.13-3.35]
ISC40FF-PA/FP4 L=79.5-85 [3.13-3.35]
Stainless
72 L
steel
/FF4 PVDF
/FP4 Polypropylene
Figure 3: Flow fitting ISC40FF-P, ISC40FF-F
IM 12D07K04-01EN-P
9
/FS1 SS
ISC40FF-SA
/FS2 SS
/FS3 SS
/FS4 SS
Figure 4: Flow fitting ISC40FF-S
IM 12D07K04-01EN-P
10
IM 12D07K04-01EN-P
11
Note O-ring 53.34 x 5.33 (K1500DD) is used as a FFKM replacement for the Ring DN50.
IM 12D07K04-01EN-P
12
Pressure
Model ISC40FS-FCSA : Max. 10 bar (150 PSI) at 20°C (68°F)
Max. 1 bar (15 PSI) at 130°C (266°F)
Model ISC40FS-PCSA : Max. 6 bar (90 PSI) at 20°C (68°F)
Max. 1 bar (15 PSI) at 100°C (212°F)
Model ISC40FS-SCSA : Max. 10 bar (150 PSI) at operating temperature
Model ISC40FS-SCWN : Max. 10 bar (150 PSI) at operating temperature
Note (2): If required the ISC40 sensor type GG and TG can be supplied with a Viton
gasket K1500AM (ordered as spare part). This gasket may be used with the older
series of ISC40FS fittings. It should be discarded when the sensor is mounted in com-
bination with the ISC40FS type FCSA and PCSA.
IM 12D07K04-01EN-P
13
IM 12D07K04-01EN-P
14
3.3 DIMENSIONS
Dimensions in mm (inches)
IM 12D07K04-01EN-P
15
-F Polyvinylidenefluoride (PVDF)
IM 12D07K04-01EN-P
16
IM 12D07K04-01EN-P
17
Pressure
Model ISC40FD-S : Max. 10 bar (150 PSI) at operating temperature
Model ISC40FD-V : Max. 2 bar (30 PSI) at 20°C (68°F)
Max. 1 bar (15 PSI) at 80°C (176°F)
Note: If required the ISC40 sensor type -GG and -TG can be supplied with a Viton
gasket K1500AM (ordered as spare part). This gasket may be used with the older
series of ISC40FD fittings. It should be discarded when the sensor is mounted in
combination with the ISC40FD type -S and -V.
IM 12D07K04-01EN-P
18
IM 12D07K04-01EN-P
19
[1.97] [2.00]
IM 12D07K04-01EN-P
21
-5 0.5 meter
-6 0.6 m
-7 0.7 m
-8 0.8 m
-9 0.9 m
-10 1.0 m
-11 1.1 m
-12 1.2 m
Length
-13 1.3 m
-14 1.4 m
-15 1.5 m
-16 1.6 m
-17 1.7 m
-18 1.8 m
-19 1.9 m
-20 2.0 m
-NFL No flange
IM 12D07K04-01EN-P
22
IM 12D07K04-01EN-P
23
5. CHEMICAL COMPATIBILITY
Table 6: Chemical compatibility chart
IM 12D07K04-01EN-P
IM 12D07K04-01EN-P