Professional Documents
Culture Documents
QF270
QF270
General Data QF
Peformance Range
H H
[feet] [m]
2624 800
60 Hz, SF 1.15
1968 600
1312 400
656 200
328 100
262 80
197 60 QF 125
QF 100
QF 160
QF 210
QF 270
QF 360
QF 1.5
QF 12
QF 20
QF 25
QF 75
QF 30
QF 50
QF 1
QF 2
QF 5
QF 6
131 40
66 20
33 10
1 2 4 6 8 9 10 20 40 60 80 100 200 400
Q [m³/h]
1 2 3 4 6 8 10 20 40 60 80 100
Q [l/s]
2
Submersible Pump
General Data QF
QF30,QF50,QF75,QF100,QF125,QF160,
Maximum Liquid Temperature:
QF210,QF270,QF360 Curve
Installation
Motor Flow velocity- Vertical Horizontal l Q/H : The curves are inclusive of valve and inlet losses
past motor at the actual speed.
Shakti 0.15 m/s 400c 400c Operation without non-return valve will increase the
4", 6" & 8" actual head at nominal performance by 0.5 to 1.0 m.
l NPSH The curve is inclusive of suction case and shows
Operating pressure: Maximum 810m (81 bar)
required inlet pressure.
l Power Curve: It shows pump power input at the actual
speed for each individual pump size.
l Efficiency Curve : Efficiency shows pump stage
efficiency.
3
Submersible Pumps
General Data QF
Pump Range
Type QF 1 QF 1.5 QF 2 QF 5 QF 6 QF 12 QF 20 QF 25 QF 30 QF 50 QF 75 QF 100 QF 125 QF 160 QF 210 QF 270 QF 360
Motor Range
0.25
0.37
0.55
0.75
18.5
132
147
185
190
170
220
1.1
1.5
3.0
3.7
4.0
5.5
7.5
2.2
9.2
110
13
15
26
30
37
45
63
75
92
22
55
11
MotorOutput[kW]
Single Phase + + + + + + +
Three Phase + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
Rewindable motor + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
4
Submersible Pump
Submersible Pumps QF
QF360
duty point.
QF210
QF270
QF100
QF125
QF160
QF50
QF75
High Pumps Efficiency
QF30
QF25
QF12
QF20
QF6
Often pump efficiency is a neglected factor compared to
QF5
the price however, the observant user will notice that
QF2
QF1.5
price variations are without importance to water supply
QF1
economics compared to the importance of pump and
motor efficiencies.
Example:
When pumping 125 m3/h with a head of 200m for a period
of 10 years $ 60,000 will be saved if a pumps and motors
having a 10% higher efficiency is chosen and the price is
$ 0.10 per kWh.
Applications
We offers a complete range of pumps and motors which
as a standard are made completely of stainless steel
AISI - 304. This provides for good wear resisrance and a
reduced risk of corrosion when pumping ordinary cold
water with a minor content of chloride.
5
Submersible Pump
Submersible Pumps QF
CT 0401 0113003
All bearings are water-Lubricated and have a squared shape
enabling sand particles, If any, to leave the pump together
with the pumped liquid.
CT0401 3247003
Inlet Strainer
The inlet strainer prevents particles over a certain size form
entering the pump.
Non-Return Valve
All pumps are equipped with a reliable non-return valve in
the valve casing preventing back flow in connection with
CT0401 3242003
pump stoppage.
Furthermore , the short closing time of the non-return valve
means that the risk of destructive water hammer is reduced
to a minimum.
The valve casing is designed for optimum hydraulic
properties, to minimize the pressure loss across the valve NRV Flape
and thus contributes to the high efficiency of the pump.
Priming Screw
All QF and QF 30 pumps are fitted with a priming screw.
Consequently, dry running is prevented because the priming CT 0401 0242001
6
Submersible Pump
Submersible Pumps QF
seat retainer 70
3b Upper valve Stainless Steel 304 316
39
seat retainer
2
4 Top chamber Stainless Steel 304 316
6 Upper bearing Stainless Steel NBR 304 316 3b
8 Bearing NBR 1d
3a
8a Washer Cabron/graphite
6
for stop ring HY 22 in PTFE mass
8a
8b 4
8b Stop ring Stainless Steel 316 316
11c
9 chamber Stainless Steel 304 316
11 split cone nut Stainless Steel 304 316 7
11c Nut for stop ring Stainless Steel 316 316
8 9
12 Split cone Stainless Steel 304 316
13 Impeller Stainless Steel 304 316
14 Suction Stainless Steel 304 316
Interconnector 13
72
15 Strainer Stainless Steel 304 316
7
16 Shaft complete Stainless Steel 431 316
8 9
17 Strap Stainless Steel 304 316
18 Cabel guard Stainless Steel 304 316 16
11
7
Submersible Pump
Performance Curve QF270
[ft] [m]
3
500 SP 160 M (QF 270)
150
60 Hz, SF 1.15
-3 ISO 9906 Annex A
140
130 -3-A
400
120
-3-AA
110
100
-2
300
90
-2-A
Head
80
70 -2-AA
200
60
50 -1
40
-1-A
100 30
20
10
0 0
[%] Efficiency [m]
DOC-SPL-0401-QF27060 0270
80 16
Efficiency
60 12
NPSH
40 8
20 4
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
FLOW RATE
65
Submersible Pump
Performance Curve QF270
[ft] [m]
SP 160 M3 (QF 270)
-10 60 Hz, SF 1.15
1500 460
ISO 9906 Annex A
440
1400 -9
420
400
1300
380 -8
1200
360
340
1100 -7
320
1000
300
-6
280
900
Head
260
800
240 -5
220 -5-A
700 -5-AA
200
-4
600 180 -4-A
-4-AA
160
500
140
400 120
100
300
80
200 60
40
DOC-SPL-0401-QF27060 0270
[%] Efficiency
[m]
80 16
Efficiency
60 12
NPSH
40 8
20 4
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
150CU.M/H @ 500FT FLOW RATE
66
Submersible Pump
Technical Data 3
QF270
QF270-3 MTSFC200 55 2313 963 213 219 2313 963 229 232 C 1350 192 241
QF270-4-AA MTSFC200 63 2608 1118 213 219 1490 192 271
A
QF270-7 MOTOR 10" 132 3807 1937 237 237 1870 237 526
QF270-8 MOTOR 10" 147 4162 2092 237 237 2070 237 597
QF270-9 MOTOR 10" 170 4468 2248 237 237 2220 237 643
QF270-10 MOTOR 12" 185 4216 2482 286 286 1734 286 675
67
Submersible Pump
Performance Curve QF270
[hp] [kW]
SP 160 M3 (QF 270)
68 60 Hz, SF 1.15
90 ISO 9906 Annex A
64
-3
60
80
56
-3-A
52
70
48
-3-AA
60 44
40 -2
Power
50
36
-2-A
32
40
28
-2-AA
24
30 -1
20
16
20 -1-A
12
DOC-SPL-0401-QF27060 0270
8
10
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
FLOW RATE
68
Submersible Pump
Performance Curve QF270
[hp] [kW]
SP 160 M3 (QF 270)
210 60 Hz, SF 1.15
280 ISO 9906 Annex A
200
180
-9
240
170
220
160
-8
150
200
140
-7
Power
180
130
120
160
-6
110
140
100
-5
-5-A
90
120
-5-AA
80 -4
100 -4-A
70
-4-AA
DOC-SPL-0401-QF27060 0270
80 60
50
60
40
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
FLOW RATE
69