You are on page 1of 3

TECHNICAL DATA SHEET

APPROVAL REQUEST (TDS)


HCPL/02012021/01 Rev: 0 Page 1 of 1
PROJECT: PROPSED CANCER CARE FOUNDATION,CHANDRAPUR PROJECT No:
Contractor : Harsh Constructions Pvt. Ltd.

SERIAL NO: MAY 0 9 9 REV No: R 0 DATE : - 12 MAY 2021

Item: Arztruftaster ART-IO. Manufacturer: Schrack Seconet Supplier: Not Applicable


Doctor call button ART-IO.

Specification Requirement Details : As per Technical Data Sheet Attached


Location Of Use : Chandrapur Cancer Care Foundation Hospital Project
Technical Details : As attached
Attachments :
Sample Size Brochure Others
YES NO YES NO
Catalogues

For Contractor : Technical Details Specification Attached for an approval.

Comments

Submitted by : Sanjay D Dalvi Date: Signature:


For CBRE
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:


For CLIENT: ( In Case Client Approval is Required )
Accepted Accepted subject to Not Accepted

Comments

Approved by : Date: Signature:

Date 21.05.2021
Arztruftaster ART-IO.
Doctor call button ART-IO.
• 1 Arztruftaster • 2 Buchsen RJ45 • Montagerahmen • Trag-
rahmen mit Platine • Folientastatur • Funktions- und Über-
wachungselektronik.

• 1 doctor call button • 2 RJ45 sockets • Installation frame •


Supporting frame with circuit board • Membrane keypad •
Function and monitoring electronics.

Beschreibung Description
Der Arztruftaster ART-IO dient in den Krankenzim- The doctor call button ART-IO is used in hospital
mern und anderen wichtigen Räumen als Arztruftaster rooms and other key areas as doctor call button for the
für das Pflegepersonal. nursing staff.
Zum Einbau in eine Schalterdose, bestehend aus Trag- For fitting in a switchbox, consisting of a supporting
rahmen mit Platine (darauf die Funktions- und Über- frame with circuit board, with electronics for function-
wachungselektronik), sowie eine Folientastatur mit: ing and monitoring purposes as well as a membrane
keypad with:
• 1 Arztruftaste (blau) inklusive Finde-bzw
Beruhigungslicht • 1 doctor call button (blue) including a finder light/
• 2 Buchsen RJ45 für den Anschluss an den Datenbus reassurance light
• Inklusive Montagerahmen (für 1fach Dose) zur • 2 RJ45 sockets for connecting to the data bus
schraublosen Befestigung. • Including an installation frame for screw-free
attachment to an installation case.
Arztruftaster ART-IO.
Doctor call button ART-IO.

Technische Daten Technical data


Versorgungspannung: 15V bis 30V Supply voltage: 15V up to 30V
Stromverbrauch: ca. 1mA typ. in Ruhe Current consumption: ca. 1mA typ. in idle

Weitere Informationen sind der Technischen Dokumentation zu entnehmen.


ca. 1,5mA typ. pro LED ca. 1,5mA typ. per LED

Further informations can be obtained from the technical documentation.


Systemanschluss: 2 x RJ45, Datenübertragung Connector: 2 x RJ45, data transmission
RS485 nach DIN19244 mit RS485, DIN19244 standard
10,2Kbit/s with 10,2Kbit/s
Schutz: EMV, ESD durch Transzorb- Protection: EMV, ESD by transzorb
dioden diodes
Kurzschlussisolator: max. Nennstrom 500mA Short circuit isolator: max. rated current 500mA
Umgebungstemperatur: 0 bis +40°C Ambient temperature: 0 up to +40°C
Relative Luftfeuchtigkeit: 5 bis 100% Relative humidity: 5 up to 100%
Luftdruck: ≥80 kPa, bis 2000m über Meer Air pressure level: ≥80 kPa, up to 2000m above sea
Schutzart: IP44, VDE0834 Umweltklasse III Protection class: IP44, VDE0834 environmental
EMV: EN50081-1 Störemission für Class III
Wohnbereich EMC: EN50081-1 emission for
EN50082-2 Störfestigkeit für residential use
Industrie EN50082-2 emission for
Produktsicherheit: EN60950 industrial environments
Funkentstörung: EN55022B Product safety: EN60950
Gehäuse Material: Kunststoff ABS Radio suppression: EN55022B
Gehäuse Farbe: weiß RAL 9016 Case material: plastic ABS
Abmessungen: Inkl. Deckplatte Case color: white RAL 9016 Technische Änderungen vorbehalten - subject to technical modifications

83 x 80 x 36 mm (HxBxT) Dimensions: Incl. cover plate


VDE-Zertifikat: VDE0834 83 x 80 x 36 mm (HxWxD)
© Schrack Productions - K-DB-0036DE-EN_ART-IO_V1.0

VDE-certification: VDE0834

SCHRACK SECONET AG
A-1122 Wien, Eibesbrunnergasse 18 • Tel.: +43-1-81157-0 • office@schrack-seconet.com