DM52XX Series Meter
DM52XX Series Meter
4kV
Voltage
3kV
2kV
1kV
0.6kV
.05 .5 5 50 .5k 5k 1min
Time (mS) Time (Sec)
Features
1 2 3 4 5 6 0 0 0
Decimal Point
n True RMS n Full Scale kW 0.4 4.1 41 401 4,001 40,001
to to to to to to
n Low PT, CT burden 3 V Pri LL x A Pri 4.0 40 400 4000 40,000 4,00,000
n Accuracy class 1.0 IEC 61036 & Class 0.5 n Multiplying Factor: 0.01 0.1 1 10 100 1000
(Represented by
n Simultaneous sampling of Volts & Amps
decimal point)
n Accurate on distorted waveforms
n Resolution : 0.01 0.1 1 10 100 1000
n Sealed dust-proof construction - Counter : kWh/ Count 0.01 0.1 1 10 100 1000
n Quick and easy installation INTEG LED kWh/ Blink 10 or 8 10 or 8 10 or 8 10 or 8 10 or 8 10 or 8
n Reverse LED for trouble shooting - Pulse Output kWh/ Pulse 0.01 0.1 1 10 100 1000
n 3 phase 4 wire (& Single phase) - DM 5240 n Overflow Hours : 2,500 - 25,000 (at Full Load)
n 3 Phase 3 wire - DM 5230 n Pulse Width : 500 mS 50 mS
n Industrial quality n Contact Rating : 24V DC, 100 mA Max
n Fieldsettable standard full scale n Ambient : Temperature 0 - 500C
n Pulse output feature Humidity < 95% Non - Condensing
n Tamper proof cover option n Weight : 450 gms approx.
n Dimension : Bezel: 96 x 96 mm
n Depth : 80 mm behind Bezel
n Panel Cut-out : (92+0.5 in index) x (92+0.5 in index) mm
n Mounting : Flush Mounting.
Know your DM 52
Multiplying Factor (MF) What do the POWER & INTEG LEDs on the front panel do ?
The meter is calibrated for particular CT, PT ratio as mentioned on the POWER LED indicates presence of Auxiliary Power which is essential for
terminal block. When the meter is used with CT, PT of the same ratio, MF the meter operation.
is either 0.01 or 0.1 or 1.0 or 10.0 or 100.0. A decimal point has been placed
on the 9 digit ( 6 moving and 3 dummy digits) depending on the MF. INTEG LED indicates that integration of Energy is in progress. The LED
While noting the energy readings, the 9 digit energy readings need to be Blink Rate is either 10 or 8 times that of the Counter update. Hence its
taken including the decimal point. resolution is 10 or 8 times that of the Counter and can be conveniently
Example1 - PT : --/415V, CT: --/5A for this meter MF = 0.01. Hence the used for meter calibration.
decimal point placement as shown (After 4th digit). Meter constant to be calculated as shown below
1 2 3 4 5 6 0 0 0
Decimal Point No of INTG LED blinks per one count update
The above display shows 1234.56000kWh x PT ratio x CT ratio
Multiplication Factor
Example2 - PT : 11kV/110V, CT: 250/5A for this meter Note: PT ratio, CT ratio mentioned on the terminal block.
MF = 100.0. Hence the decimal point placement as shown Overflow Hours?
(After 8th digit). As the Counter accumulates kWh, it will eventually reach 999999 and then
1 2 3 4 5 6 0 0 0
Decimal Point
overflow to 000000. The duration it takes to overflow is approximately
The above display shows 12345600.0kWh equal to (999999 x MF) / average kW.
TAMPER PROOF COVER OPTION
A Tamper Proof cover enables sealing of terminal block at the rear of the
meter. This prevents tampering of connections.
Optically Isolated, Solid-state NO Contact gives digital pulse output to drive Remote Counter, PLC, DCS Station etc. for off line monitoring of Energy Data, on
line control for Energy/Power/Process optimisation, correlating Energy Input to product output etc. Applications of pulse output feature are as shown below.
V1
1
A1
9
V2
2
S2
10
S1 S1
8
V3 V1
1
3
A2 A1 S1
8
9
V1
11
V2 A1
2
VN
4
S2 S2
PT
9
10
V2
2
S1 S1
S2
V3 + Pulse -
12
3
5
Remote
A2
10
A3 S1
11
V3
Feeder1
3
Sl.No.
VN A2
P
4
13
6
S2
PT
CT
S2
11
8
Totallizer V1
1
VN
4
S1 S2
PT
12
5
14
7
9
A3
+ Pulse -
Feeder1
S1
V2
2
L
12
5
Sl.No.
13
A3
6
S1
CT
S2
8
10
S1
V1
1
Sl.No.
V3
3
13
A1
6
S2
CT
14
7
11
C
+ Pulse - V2
2
S2
VN
Presettable
4
S2
14
7
PT
+ Pulse -
10
S1
S1
V3
3
12
5
A2
Counter
A3
11
S1
8
Sl.No.
VN
4
S2
13
V1
6
PT
1
S2
CT
A1
12
5
V2
14
2
7
12v -
S2 A3
+ Pulse -
Control
Sl.No.
10
S1
13
6
V3 S2
CT
3
Feeder2 Output To
14
7
VN
4
S2
+ Pulse -
PT
S1
DC
PLC/DCS for online control of Energy Contactor
12
5
A3
Sl.No.
13
6
S2
CT
+ Pulse -
If the DCS/PLC has a self excited 12V a cost effective centralised system
or 24V Digital Input, external 24V DC to centrally monitor energy data The Presettable Counter is
Supply is not needed. Remote Totaliser can be configured and generate a variety of reports programmed with the amount of
The kWh pulses may also be used to to record Data shift- wise, day wise covering load-wise, shift- wise, day- Energy to be dispensed. When it
derive average kW information at etc., while DM 52 records total wise or batch-wise analysis of energy counts down to zero, it de- energises
the PLC. consumption. consumption. the load.