Tensile, Fatigue, and Creep Properties of Aluminum Heat
Exchanger Tube Alloys for Temperatures from 293 K to 573 K
(20 °C to 300 °C)
SÖREN KAHL, HANS-ERIK EKSTRÖM, and JESUS MENDOZA
Since automotive heat exchangers are operated at varying temperatures and under varying
pressures, both static and dynamic mechanical properties should be known at different tem-
peratures. Tubes are the most critical part of the most heat exchangers made from aluminum
brazing sheet. We present tensile test, stress amplitude-fatigue life, and creep–rupture data of six
AA3XXX series tube alloys after simulated brazing for temperatures ranging from 293 K to
573 K (20 °C to 300 °C). While correlations between several mechanical properties are strong,
ranking of alloys according to one property cannot be safely deduced from the known ranking
according to another property. The relative reduction in creep strength with increasing tem-
perature is very similar for all six alloys, but the general trends are also strong with respect to
tensile and fatigue properties; an exception is one alloy that exhibits strong Mg-Si precipitation
activity during fatigue testing at elevated temperatures. Interrupted fatigue tests indicated that
the crack growth time is negligible compared to the crack initiation time. Fatigue lifetimes are
reduced by creep processes for temperatures above approximately 423 K (150 °C). When
mechanical properties were measured at several temperatures, interpolation to other tempera-
tures within the same temperature range was possible in most cases, using simple and well-
established equations.
DOI: 10.1007/s11661-013-2003-5
Ó The Author(s) 2013. This article is published with open access at Springerlink.com
200
(°C)
50
90
Rp0.2
(MPa)
60
30
Rm
150
(MPa)
50
Fatigue
50
10 5 cyc
(MPa)
20
Fatigue
40
10 6 cyc
(MPa)
20
Creep
50
10 2 h
(MPa)
20
Creep
40
10 3 h
(MPa)
20
50 200 50 150 20 40 20 40
Fig. 1—Relations between results from different mechanical tests. If two quantities were measured for the same alloy at the same temperature,
this resulted in one point in each of the two respective plots. Fatigue strength is given in terms of stress amplitude for the indicated number of
cycles, creep strength in terms of creep rupture stress for the indicated number of hours.
Table II. Pearson Correlation Coefficients for the Data Shown in Fig. 1
stress amplitude for failure after 105 and 106 cycles, and In most cases, where two quantities appear to be
creep rupture stress at 102 and 103 hours to rupture. correlated, the correlations seem to be close to linear.
Each relation between two quantities is shown by two Therefore, we supplemented the graphical information
diagrams, where the axes are exchanged. If two quan- provided by Figure 1 with Pearson correlation coeffi-
tities were measured for the same alloy at the same test cients, which are given in Table II.
temperature, this contributed one data point in each of The following quantities have correlation coefficients
the two diagrams. Not all mechanical tests were carried between 0.9 and 1.0 and are thus strongly correlated:
out on all alloys at the same test temperatures; therefore, Tensile strength to fatigue strength after 105 cycles, and
the numbers of data points differ between diagrams. to creep strength after both 102 and 103 hours; fatigue
Line 1
Line 2
0.10
Ra
0.05
diu
s :6
9m
m
0.00
Specimen width
0 2 4 6 8 10
Distance from specimen edge (mm)
(a) (b)
Fig. 2—Transverse curvature of an Alloy-D tensile test specimen after fracture. (a) View of the fracture surface. (b) Height profile along two
lines at 70 mm distance from the fracture surface; the solid line represents a circular arc that was fitted to the data.
30
Elongation (%)
80
20
60
40
10
20
0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Testing temperature (°C) Testing temperature (°C)
(a) (b)
Fig. 3—Tensile test properties of 0.40-mm-thick braze-simulated, braze-clad AA3003 heat exchanger tube alloy at different temperatures.
1.0
1.2
0.8
0.8
0.6
0.6
0.4
AA3003 AA3003
0.4
Alloy-A Alloy-A
Alloy-B Alloy-B
0.2
0.2
Alloy-C Alloy-C
Alloy-D Alloy-D
Alloy-E Alloy-E
0.0
0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Testing temperature (°C) Testing temperature (°C)
(a) (b)
2.5
AA3003
Alloy-A
Alloy-B
2.0
Rm Rp0.2 Rp0.2
Alloy-C
Alloy-D
Alloy-E
1.5
1.0
0.5
0.0
(100 °C) prior to the tensile test at 373 K (100 °C) was The tensile strength decreased strongly with increas-
between 3 and 5 minutes. Static pre-heating for 5 or ing temperature, which means that the strain hardening
10 minutes at 373 K (100 °C) prior to a tensile test at of the material is strongly reduced at elevated temper-
room temperature did not have any influence on the atures. This was true for all investigated heat exchanger
yield strength of AA3003. At the present time, we would tube materials, and it is in fact the behavior that is
not like to speculate on further details of this strength- generally expected for fcc metals.[12] Tensile strength and
ening mechanism. the ratio of Rm Rp0:2 to Rp0.2, which represents the
100
H (MPa)
100 °C
120
180 °C
80
100
True stress (MPa)
Parameter
200 °C
80
60
250 °C
60
40
300 °C
40
20
20
Data
Regression curve
0
0
0.00 0.05 0.10 0.15 0.20 0 50 100 150 200 250 300
True strain Temperature (°C)
(a) (b)
140
20 °C
100 °C
120
150 °C
180 °C
100
True stress (MPa)
200 °C
80
225 °C
60
250 °C
40
300 °C
20
Data
Interpolated curve
0
Table III. Regression Parameters and Their Standard Errors for Fitting of Eq. [6] to Averaged True Stress–True Strain Curves of
AA3003 at Different Temperatures
to the scatter in lifetimes over the range where the power magnitude of the (negative) fit parameter a is expected.
law is valid, and the small number of data points of any By averaging all of the data for the full range of alloys
given alloy. From inspection of Figure 7, an increase in and temperatures, the expected monotonic decrease in
run-out tures where S–N fatigue data are not available. The
temperature dependence of the normalized fatigue
strengths at 105 and 106 cycles to failure can be
40
-5
Fit parameter a
-10
20
-15
-20
-25
4 5 6 7
10 10 10 10 AA3003 Alloy-B Alloy-D
Number of cycles N Alloy-A Alloy-C Alloy-E
Normalized Δσ at 10 cycles
1.2
1.2
1.0
1.0
5
6
0.8
0.8
0.6
0.6
0.4
0.4
AA3003 AA3003
0.2
0.2
Alloy-A Alloy-A
Alloy-B Alloy-B
Alloy-C Alloy-C
0.0
0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Testing temperature (°C) Testing temperature (°C)
(a) (b)
Fig. 8—Fatigue stress amplitude, normalized to the respective value at 373 K (100 °C), at (a) 105 cycles and (b) 106 cycles as a function of tem-
perature. Only alloys without Mg-Si precipitation hardening and with data available at 373 K (100 °C) were included. The dashed lines represent
Eqs. [8] and [9].
Normalized Δσ at 10 cycles
1.0
1.0
5
6
0.8
0.8
0.6
0.6
0.4 AA3003 AA3003
0.4
Alloy-A Alloy-A
Alloy-B Alloy-B
Alloy-C Alloy-C
1.0
run-out
¼ 1:23 T T
DrT¼100 C N¼105 C
ð CÞ6
0.8
½8
0.6
Dr 1:91 104
¼ 1:05 þ T
DrT¼100 C C
N¼106 0.4
ð CÞ2 ð CÞ4
½9 Fit of ln(N ) = a ⋅ ln(Δσ) + ln(b )
0.0
4 5 6 7
10 10 10 10
For the Basquin law, we can now calculate the Number of cycles N
coefficients a and b from Eqs. [8] and [9] for any
temperature where these two equations are assumed to Fig. 11—Stress amplitude-fatigue life data for Alloy-E at different
be valid. From Figure 7, the agreement between the S–N temperatures, normalized to the maximum stress amplitude. Dashed
curves based on Eqs. [8] and [9] with the measured data lines correspond to separate fits of Eq. [7] for each temperature. The
can be assessed. The closeness of agreement is obviously specimens tested at 523 K and 573 K (250 °C and 300 °C) were kept
directly related to the difference between fitted curve and for the indicated time at the testing temperature prior to the test.
data point of the respective alloy—here AA3003—in
Figure 8. At 453 K (180 °C), the normalized fatigue Naturally aged material possesses higher fatigue
strengths at both 105 and 106 cycles to failure are below strength at 453 K (180 °C) than at the lower testing
the fitted curve; therefore, the estimated fatigue strength temperatures for high numbers of cycles. The reason for
(solid line) is a bit too high at this temperature. this behavior is that the material is further strengthened
While Eqs. [8] and [9] can be used to predict S–N by artificial aging during the fatigue test at 453 K
curves for any of the four alloys from Figure 8 at any (180 °C). The combination of temperature and defor-
temperature between 293 K and 573 K (20 °C and mation in AA6XXX series alloys leads to enhanced
300 °C), the agreement with the data points is clearly precipitation kinetics and changed precipitation se-
better for the separately fitted Basquin equations than quence as compared to static heat treatment.[26–28]
for the combined fit. The fatigue strength at 523 K (250 °C) of the material
We mentioned previously that the S–N curves of that had been heat-treated for 28 days at testing
Alloy-E were strongly influenced by Mg-Si precipita- temperature is significantly smaller than the fatigue
tion. Figure 11 shows fatigue curves for this material strength of the material that had been heat-treated for
after several weeks of natural aging and after several only 24 hours; a heat treatment of 28 days at 523 K
weeks of natural aging plus a static heat treatment for (250 °C) causes strong over-aging of the Mg-Si precip-
the indicated time at the testing temperature, prior to itates and a corresponding loss of the strengthening
the fatigue test. effect from these precipitates.
Table IV. Comparison of Tensile Properties and Fatigue Strength for Alloy-A and Alloy-E
Fig. 12—Edges of fatigue test specimens made from Alloy-A, loaded at 373 K (100 °C), showing (a) slip lines, (b) a small crack. Four slip lines
in (a) are marked by dashed lines.
1.0
crack initiation
failure by fracture function FG (represented by the dashed line) from the
measured data of the first test series was set equal to a
sp
0.8
shift of the dashed line by the standard deviation of the
ec
Failure probability F
im
mean value of the logarithmic lifetime, Sln N . The
sp
en
ec
corresponding ‘‘confidence band’’ is shown by the two
im
8
sp
e
0.6
n
dotted lines. (2) The experimental error in deciding
ci
7
m
sp
en
ec
whether a crack had formed or was not set equal to one
6
im
sp
en
false decision on n2nd samples, corresponding to an error
ec
0.4
im
5
sp
of 1=n2nd . (3) The upper bound for Ng was then
en
ec
4
i m
calculated from the probability FG ðln N2nd Þ þ 1=n2nd
en
3
and from the dotted line that corresponds to a mean
0.2
Measured ln(N)
Normal distribution during fatigue testing of flat specimens at room temper-
'Confidence band' ature by Buteri et al.[6] Specimens were braze-simulated
0.8
500
300
400
Force (N)
Force (N)
300
200
200
100
100
1 2 34 1 2 3 4 5 6 789
0
0
0 1 2 3 4 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Cylinder displacement (mm) Cylinder displacement (mm)
(a) (b)
Displacement per cycle (mm)
3.0
Room temperature
180 °C
2.5
2.0
1.5
1.0
0.5
0.0
0 10 20 30 40 50
Cycle number
(c)
Fig. 15—Force–displacement curves for the first fatigue cycles, carried out at the reduced frequency of 0.1 Hz on Alloy-A, (a) at room tempera-
ture, (b) at 453 K (180 °C). Displacement was measured from the position of the hydraulic cylinder of the fatigue test device. Displacements per
cycle are compared for both testing temperatures in (c).
unclad, 280 °C
agreement with the fact that we observed signs of creep
during fatigue testing at 453 K (180 °C). 10 10
2
10
3
10
4
10
5
1.0
Normalized σR at 1000 h
Normalized σR at 100 h
0.8
0.8
0.6
0.6
0.4
0.4
0.2
0.2
0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Testing temperature (°C) Testing temperature (°C)
(a) (b)
Fig. 18—Creep rupture strength, normalized to the respective tensile strength at 293 K (20 °C), as a function of temperature at (a) 100 h and (b)
1000 h to failure.
80
Room temperature
60
6
10
creep resistance.
On the other hand, the different alloys shown in ue
40
tig
Table I possess significant variations in their popula- fa
6
tions of intermetallic particles because of their different
20
10
compositions. Such particles, based on the alloying
elements silicon, iron, copper, manganese, magnesium, 1000 tensile strength
0
cre
9.25
zirconium, and titanium, are more stable at elevated ep tensile strength
temperatures than Mg-Si precipitates are. Also the solid
solution levels of silicon, copper, manganese, magne- 0 20 40 60 80 100 120 140
sium, and titanium are expected to vary significantly Mean stress (MPa)
between the six different alloys.
Indications exist that manganese atoms in solid Fig. 19—Influence of stress amplitude and mean stress on specimen
solution lead to a stronger increase of creep strength lifetimes at two different temperatures, for different types of mechan-
ical tests. Numbers for fatigue tests indicate cycles to failure and
than manganese atoms in dispersoids or particles.[8] This numbers for creep tests hours to rupture. 106 cycles of fatigue test-
is in agreement with the fact that the strengthening effect ing correspond to 9.25 h test duration. Both axes of the figure have
of manganese-containing dispersoids strongly dimin- the same scale.
ishes as the strain increases.[39] If we then hypothesize
that creep strength is dominated by one strengthening
mechanism in the alloys of this investigation, namely the data points at 573 K (300 °C), i.e., the fatigue
solid solution strengthening, it is plausible that the lifetime for 106 cycles to fracture at 30 Hz testing
temperature dependency of normalized creep strength is frequency and the creep rupture time of 9.25 hours, it
very similar for the different alloys. can be seen that the influence of mean stress is stronger
than the influence of stress amplitude on the specimen
lifetime.
E. Relation Between Fatigue and Creep at High At room temperature, the situation is the opposite;
Temperatures the slope of the dashed line connecting the data points is
It has long been known that cyclic loads at elevated less than one in magnitude, which means that stress
temperatures activate damage mechanisms that have amplitude has a stronger influence on specimen lifetime
aspects of both creep and fatigue. Depending on the than mean stress. Since creep is negligible at room
starting point, such mechanisms can be considered as temperature, the constant stress that leads to specimen
‘‘time-dependent fatigue’’[29] or as ‘‘fatigue-perturbed failure after 9.25 hours coincides with the tensile
creep’’[40] or ‘‘cyclic creep.’’[41,42] For aluminum or strength.
aluminum alloys, it was reported in several cases that At 573 K (300 °C), the lifetime depends on the time at
load cycling between a high and a low tensile stress gives stress as is obvious from the creep test results. This is
shorter lifetimes than static loading at the high also true for the case of nonzero stress amplitudes and
stress.[40,41] It was also shown, though, that both means that a reduction in fatigue testing frequency
acceleration and retardation of strain rates may occur would lead to a reduction in number of cycles to failure.
in cyclic creep of aluminum, depending on stress, stress It should be noted that data points from fatigue tests
amplitude, and testing frequency.[42–44] Testing frequen- with a stress ratio 0.1 < R < 1, other than R = 0.1 used
cies in these cyclic creep investigations did not exceed in our fatigue tests, could deviate from the dashed lines
1 Hz.[40–44] in Figure 19[45]; these lines are only meant to connect the
In Section III–C, two indications were given that two data points at each temperature and to illustrate the
creep mechanisms reduced the fatigue strength at general trend.
elevated temperatures: The temperature dependence of The dominating creep-type damage contribution dur-
the fatigue strength did not follow the extended Basquin ing fatigue testing at high temperatures also becomes
equation suggested by Kohout,[24] and the plastic strain obvious from the fracture surfaces. Figure 20 shows the
during low-frequency fatigue loading of Alloy-A at fracture surfaces of AA3003 specimens after fatigue and
453 K (180 °C) increased from cycle to cycle. creep testing at 573 K (300 °C). Both fracture surfaces
From the data collected during our study, we can also are characterized by very strong reductions in area and
see that the influence of mean stress as compared to the large cavities.
influence of stress amplitude on the specimen lifetime However, we should not expect that creep and fatigue
increases with increasing temperature. loads at high temperatures generate exactly the same
In Figure 19, we have connected by dashed lines the type of fracture and damage: The microstructure never
data points that correspond to same specimen lifetimes reaches a stationary state during the fatigue tests where
at the respective temperatures, room temperature and the applied stress varies sinusoidically with the testing
573 K (300 °C). From the slope of the line that connects frequency of 27 to 30 Hz.