You are on page 1of 6

WWW.VENTEXINC.

COM
TEL (905) 857-4700
PARTS AND SUB-ASSEMBLIES OF PENTHOUSE PH-IOM-REV1
NOV-2023

END CONNECTION #12-3/4-SELF DRILLING


LH-ROOF CLIP MULLION CORNER

3/8-16 X 2-1/2" 3/8-16X1-1/2"


MID-ROOF ROOF DEFLECTION BEAM HEX HEAD BOLT HEX HEAD BOLT

3/8-16
RH-ROOF SUPPORT STRUCTURE 3/8 WASHER NUT ZINC PLATED

PENT HOUSE

LOUVER-S1 LOUVER-S2 #8-15-3/4"-SELF DRILLING PAGE-1


WWW.VENTEXINC.COM
TEL (905) 857-4700
PENTHOUSE ASSEMBLY INSTRUCTIONS PH-IOM-REV1
NOV-2023

MULLION CORNERS POSSIBLY


ASSEMBLED AT THE FACTORY

1 S1-B
2 S1-AB
S2-B

S1-A

A
BOLT S1 LOUVERS
TOGETHER

S2-A

#8-15-3/4" SELF TAPPING


SCREW

3/8-16X2-1/2" BOLTS

DETAIL A
SCALE 1 : 5

ALL THE REQUIRED HOLES NEEDS


TO BE BOLTED AND SCREW WITH
THE CORRECT SIZE OF BOLTS,NUTS DETAIL B
AND SCREWS SCALE 1 : 3
WWW.VENTEXINC.COM
TEL (905) 857-4700
PENTHOUSE ASSEMBLY INSTRUCTIONS PH-IOM-REV1
NOV-2023

3 S1-AB
S2-A
4 S1-AB
E
S2-AB
H DETAIL F
S2-B SCALE 1 : 7

S2-A
#8-15-3/4" SCREWS
C
S2-AB

S2-B
DETAIL E
SCALE 1 : 12

S2-AB BOLTED TOGETHER


3/8-16 X 2-1/2"
BOLTS
SCREW BOTH THE SECTIONS OF LOUVER
AND SUPPORT STRUCTURES WITH THE
DETAIL G END CONNECTIONS
SCALE 1 : 25

ALL THE REQUIRED HOLES NEEDS DETAIL C THE VERTICAL SUPPORT CHANNEL IS
TO BE BOLTED AND SCREW WITH BOLTED WITH 1/4"-20 BOLTS FROM
THE CORRECT SIZE OF BOLTS,NUTS
SCALE 1 : 10
THE TOP AND THE BOTTOM SECTION OF DETAIL H
AND SCREWS SUPPORT STRUCTURES SCALE 1 : 7
WWW.VENTEXINC.COM
PENTHOUSE ASSEMBLY INSTRUCTIONS TEL (905) 857-4700
PH-IOM-REV1
NOV-2023

5 X 6 S1-AB
S1-AB

S2-AB S2-AB

S2-AB S2-AB

S1-AB
S1-AB

1X1L
3/8-16 BOLTS
S2-AB

#8-15-3/4" SCREWS 1/4"-20 BOLTS

ALL THE REQUIRED HOLES NEED


DETAIL X TO BE BOLTED AND SCREWED WITH
THE CORRECT SIZE OF BOLTS ,NUTS
SCALE 1 : 4
AND SCREWS PAGE-4
WWW.VENTEXINC.COM
PENTHOUSE ASSEMBLY INSTRUCTIONS TEL (905) 857-4700
PH-IOM-REV1
NOV-2023

7 S1-AB
8
S1-AB

S2-AB
S2-AB

Q
S2-AB
S2-AB

S1-AB
S1-AB

3/8-16 X 2-1/2''
BOLT #12-3/4"SELF TAPPING

SCREWED TO THE H/S


AND JAMB OF THE LOUVER
#8-15-3/4" SCREWS

ALL THE REQUIRED HOLES NEED


TO BE BOLTED AND SCREWED WITH
THE CORRECT SIZE OF BOLTS ,NUTS
AND SCREWS PAGE-5
WWW.VENTEXINC.COM
PENTHOUSE ASSEMBLY INSTRUCTIONS TEL (905) 857-4700
PH-IOM-REV-1
NOV-2023

9
SCREW ALL THE
S1-AB ROOF PANEL TO THE HEAD
OF THE LOUVERS 10 S1-AB
S2-AB
S2-AB ROOF GETS
INTERLOCKED
W

R1

R3
S2-AB DETAIL W S2-AB

SCALE 1 : 5 S1-AB
R2
S1-AB

#12-3/4" SELF TAPPING SCREW COMPLETE ASSEMBLY OF PENTHOUSE


ALL THE EXPOSED SCREWS HAVE A
RUBBER GASKET TO PREVENT LEAKAGE

#12-3/4" SELF TAPPING SCREW CAULK ENDS (WEATHER SEAL END JOINTS)

10"-16"
INTERLOCK SPACING

DETAIL T
ROOF FLANGE REQUIRES
SCALE 1 : 2 MINIMUM 2 SCREWS PER PANEL

DETAIL Y VENTEX DO NOT TAKE THE LIABILITY FOR MOUNTING OR


ALL THE REQUIRED HOLES NEED TO BE THE DAMAGE THAT OCCURS DURING THE MOUNTING OR
SCALE 1 : 7
BOLTED AND SCREW WITH THE CORRECT INSTALLATION OF PENTHOUSE
SIZE OF BOLTS,NUTS AND SCREWS PAGE-4