You are on page 1of 39
© Dunedin City Council - Building Control Section 45 ond Section 216, Bung Act 2004 Use this form for + Additional information required for applications + As Built plans Tick one | Building Consent Number. Additional Information (BC not Issued) ‘Additional Information (BC Issued, Minor Amendment) v | Zou 6/7. As Built Plans PROJECT DETAILS (person submitting the amendment to complete) Project Location Original consent use Otago Settles Wuseow | Description of TS, did: ay 2 baildong amendment ee 2Oih wen colrec Value of additional work | 5 (, | (if applicable) Mailing address | (for documentation) Applicant Fax Contact Name Phone FOR COUNCIL USE Received date Koy = Mart Uap Doiz Receiving Officer y Additional fees required YES 7 IO ‘Amended PIM required = Checked by Date Time taken Cost BCO to fill in these columns (in minutes) | (minutes x ey Rate) Buildi Plumbing and Drainage Planning. a Roading mi ‘Water Health zr Inspections ‘Administration BRANZ DBH Plan/s approved for issue Invoice sent to applicant Plans sent/handed to applicant Total additional feos NOTE: PLANS ARE NOT TO BE GIVEN TO THE CUSTOMER UNTIL FEES ARE PAID Page 1 oft DCCBCA-F3-02-¥2.0, Page 1 of 2 Cam Allum From: Damyn [Darryn@bakergarden.co.nz] 2 4 Sent: Wednesday, 16 May 2012 12:38 p.m. 017-1697, 6% To: Cam Allum Ce: Nick@bakergarden.co.nz Subject: OTAGO SETTLERS MUSEUM STAGE 4: ABA2011-1617: ALCOTEX FR substitute for ALUCOBOND. Attachments: OSM4-Symonite markups.pdf. Symonite typical details 2012 full set pdf Hi Cam, As per Baker Garden Architect Letter dated 24th April 2012 and subsequent telephone discussion between yourself and Nick Baker (Principal) we now provide you with the following additional information. Please find attached the Standard SYMONITE ALUMINIUM COMPOSITE CLADDING Manual which relates to the ALUCOMAT and ALCOTEX FR (Symonite typical details 2012 full set). Thave had it confirmed by SYMONITE that the details are the same for both products. We are using the ALCOTEX FR. 1 also attach a Markup of A54.10 and A64.05 highlighting the changes in details and what SYMONITE details are to be applied (OSM4-Symonite markups.pdf. In summary: Detail 01/A54,10: each 1350mm wide panel is to have 2-8mm drainage holes fitted with ‘grommets, 50mm from panel ends. Detail 01/A64.05: the front section (from Grid G13) on the SYMONITE details appears to require a underflashing as per SYMONITE detail sheet 5.3, Detail 05/A64.05: vertical junction is to be formed up using SYMONITE detail sheet 1.0 - detail 2. Detail 06/A64.05: precast junction is to be formed up using SYMONITE detail sheet 8.0. Detail 07/A64.05:Gable end junction is to be formed up using SYMONITE detail sheet 4.1 - details 1 & 2. Other than that the fixing methods to the Structure are the same with fixing at 600crs through a angle rivet fixed to the ALCOTEX FR typically shown on SYMONITE detail sheet 1.0, 2.0 and 4.1, rather than a fold and lapped fold of Alucobond. ‘Once you have reviewed this email and the previous correspondence noted above, can you please confirm whether you can process this change as a Amendment to Building Consent ABA 2011- 1617. We look forward to your response in the next day or two if possible please as unfortunately this, item has now become somewhat urgent. Cheers 17/05/2012 Page 2 of 2 Darryn Greer BAKER GARDEN ARCHITECTS 5th Floor, Consultancy house 007 Bond St P.0.Box 203 M: 0274 800 146 Dunedin W: ww bakergarden co.nz ‘The information inthis transmission may be confidential and must not be used other than by the sender and intonded recipient. Pease phone our office collect if you recanve this transiission by mistake, {nthe imerest of minimising the wastage of paper plsase consider the environment before printing this email 2077-1647, 17/05/2012 BAKER GARDEN 2071. 1697,_ P.O. Box 203 Dunedin Phone (03) 477-5214 Fax (03) 477-5212 architect@bakergarden.co.nz 24 April 2012 Bob Phease Pro-eo &E Attn: Mr. Neil McLeod. abe. Dear Sir, DUNEDIN CITY COUNCIL New Entrance Foyer for Otago Settlers Museum Building Consent No ABA 2011-1617 The Contractor on this Project Lund South Ltd has requested a change to the Aluminium Composite Panel (ACP) lining to the building soffit and internal ceiling. The original specified product was ALUCOBOND and the proposal is to substitute this product with ALCOTEX / FR. ‘The ALCOTEX / FR is distributed in New Zealand by Symonite New Zealand Ltd who has had their cladding system using ALCOTEX / FR appraised by BRANZ (BRANZ Certificate No. 528(2006) Copy attached). We have reviewed the ALCOTEX / FR technical specifications and the BRANZ appraisal Certificate No, 528 and are satisfied that the product is a suitable substitution. The project Fire Engineers Cosgroves have reviewed the product and are satisfied that ALCOTEX / FR meets the NZBC Fire safety requirements for the project. Copy of Cosgroves Consultant Advice Notice No. F01 is attached. Can you please confirm that the use of ALCOTEX / FR instead of ALUCOBOND is acceptable to the DCC Building Control on this project. Please Contact the undersigned directly if you require any further clarifications. Yours faithfully Baker Garden tects Ltd Nick Baker FN Encl; Cosgroves CA No.FO1 BRANZ Appraisal No. 528(2006) Ce Adrian Thien OCTA Tony Taylor DCC City Property N.R. Baker, 8.Arch., A.N.Z.1.A. A.M. Garden, B.Arch., F.N.Z..A 5th Floor Consultancy House, 7 Bond St, Dunedin D) roves 2n%11.1647, CONSULTANTS ADVICE NOTICE 3 | cosg Date: 43” April 2012 File Ref: 7026F Fire Engineering | #eQ Issued By: Brady Cosgrove Project Name: Otago Settlers Museum — Stage 4 No. of Pages: 1 page This Consultants Advice Notice shall be read in conjunction with the original Contract Documentation, the relevant clauses of which shall apply to all aspects of the work identified below. ADVICE: Type 1. Aleotex Alucobond Altemate Refer the background data for the proposed AlcotewFR product. Based on this information we agree that is it acceptable for the proposed soffit use inthe B Stage 4 works in terms of NZBC Fire Safety requirements. END DISTRIBUTION: x Darryn Greer, Baker Garden x Adrien Thein, Octa X Lloyd Reddington, Chas E George x Brent Cooper, Fire Protection Engineers (0 = no attachments x= with copies of relevant attachments. rawing attachments sent under separate cover ‘A Contract interpretation not involving variation 1B _ Variation for immediate action (Price to be submitted within one calendar month) © _Vatiation price request (Price must be approved before work proceeds BRANZ Appraised ‘Appraisal No.528 [2006] BRANZ Appraisals Technical Assessments of products for building and construction BRANZ APPRAISAL No. 528 (2006) ‘Amended 17 November 2009. ‘Symonite New Zealand Ltd P 0 Box 12 400 Penrose Auckland Tel: 09 570 7077 Fax: 09 574 6910 RAN Lined ‘Private Ban 50908 cy New ‘Tek 64420710 ax o684207 101 ‘woneram.c0.2 ZS 2011-1617, 1 1.1 The Symonite New Zealand Cladding System is an open rainscreen external wall cladding for specific design buildings of timber frame or timber frame infil construction The system incorporates Symonite, Alucomat or Alcotex aluminium composite sheets, ‘manufactured by adhering PVDF coated aluminium to a phenolic resin for the Symonite sheets, to a polyethylene or polyethylene and mineral fibre core for the Alucomat sheets and the Alcotex sheets. 1.2 The aluminium composite pane! sheets come in thicknesses of 4mm and have their edges folded to create a deeper cladding panel. A wide variety of colour options are available for the panels 1.3. The system incorporates a primary and secondary means of weather resistance (first and second line of defence) against water penetration by separating the cladding from the supporting timber framing with a nominal 20 mm cavity. The cavity allows for any ‘occasional ingress of water that may get past the external skin to drain to the exterior of the building, and any remaining moisture to dry by evaporation. 2.1 The Symonite New Zealand Cladding System has been appraised for use as an open rainscreen external cladding system for buildings within the following scope: ‘buildings of importance level I to 5 as described by AS/NZS 1170, except that housing and communal residential buildings that fall within the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 are excluded; and, + constructed with timber framing, or timber framing infill complying with the NZBC; and, + subjected to maximum wind pressures for weathertightness design of 2.5 kPa Ultimate Limit State (ULS); and, + where the cavity 's drained and ventilated at least at every second floor level or 10 m height, whichever isthe lesser. 2.2 All buildings incorporating the Symonite New Zealand Cladding System must be subject to specific engineering and weathertightness design. Building designers are responsible for the incorporation of the Symonite New Zealand Cladding System into their design in accordance with the instructions of Symonite New Zealand Ltd, using the details given in the Technical Literature, and for designing all details not covered by this Appraisal. 2.3 The instalation of the Symonite New Zealand Cladding System is to be carried ‘out by people trained by Symonite New Zealand Ltd specifically forthe task. 2.4 Window and door joinery installations in the Symonite New Zealand Cladding System must be subject to specific weathertightness design. Building designers are responsible for verfying the performance ofthe joinery installation details. (The Appraisal of the Symonite New Zealand Cladding System relies on the joinery being the subject of specific engineering design with regards to wind load and deflection for the design wind pressure.) Readers are advised to check the validity of this Catifate by refering te the Valid Crtifeateslstingon the BRANZ website, or by contacting BRANZ. Guiting Reguiations 3:1 Inthe opinion of BRANZ, the Symonite New Zealand Ciadaing System, if designed, used, Installed and maintained in accordance with the statements and conditions of this Appraisal, wil meet of contribute to meeting the fllowing provisions of the New Zealand Building Code (NZBC): Clause B1 - STRUCTURE: Pertormance 1.3.1, 61.3.2 and 81.3.4. The Symone New Zealand Ciading System meets the requirement or loads ang fom set weight, earthquake, wind, impact and creep [i.e. B1.3.3 (a), (f), (h), (j) and (q)]. See Paragraphs 9.1 ~ 9.4 Clause B2 ~ DURABILITY: Performance 82.3.1 (b) 15 yeas. The Symone New Zealand Gadsing. System meets ths requirement, See Paragraphs 10.1 ~ 10.4 Giause C3 ~ SPREAD OF FIRE: Performance (3.3.5. The Symonite New Zealand Cladding System meets this requirement See Paragraphs 11.1 and 11.2 Clause £2 ~ EXTERNAL MOISTURE: Performance €2.32. The Symonite New Zealand Gladding System meets his requirement. See Paragraphs 12.1 and 12.2 Clause F2 HAZARDOUS BUILDING MATERIALS: Performance £2.31. The Symonite New Zealand Cladding System meets this requirement and wil not present a health hazard to people. 3:2 This san Appraisal an Allemative Solution in terms of New Zealand Bulding Code Compliance [ieciuted Speciation | sizes that may be achieved by panels. Panels are attached to ee i 2011.1617, Accessories 4.8 Accessories used with the Symonite New Zealand Ciadding System that are supplied by Symonite New Zealand Utd include: + Screws for panel fixing Aluminium angie fixing brackets Plastic packers PEF backing ro Sikafiex® AT-Facade Holdfast® Fix All€ 220LM MS Polymer Holdfast® Carbond 940 FC Adhesive Gator UHB pressure sensitive tape. Handling and Storage 5.1 Handling of the aluminium composite panels and the associated accessories must be in accordance with the Symonite New Zealand Cladding System Technical Literature and Symonite New Zealand Ltd's instructions edintted) (Uncrate 6.1 Refer tothe Appraisals Ising on the BRANZ Webalte for details of the current Tecnical Literature forthe Symonite New Zealand Cidding Sytem. The Technical Literature must te read in conjunction wih this Appraisal, All expects of Gesign, use, installation anc maintenance contained within the Teennicl Literature and within the scope ofthis Appraisal must be flowed, Uatteramettion General 7.1. The Symonite New Zealand Cladding System is used (on buildings that have been subject to specific engineering, weathertightness and fire design, 7.2 All aluminium components of the Symonite New Zealand Cladding System must be kept out of contact with ‘treated timber that contains copper (e.g. CCA, copper azole or CQ), Framing Timber Treatment 8.1 Timber wall framing behind the Symonite New Zealand Wall Cladding System must be treated as required by NZS 3602 Timber Framing 8.2 The bullding designer is responsible for the framing design using wind pressures calculated in accordance with ASINZS 1170 considering local factors. Structure Impact Resistance 9.1 The system will resist human impact loads likely to be encountered. The surfaces of Symonite and Alucomat sheets are susceptible to impacts from hard and sharp bodies. Care must therefore be taken when installing the system. The likelihood of impact damage to the system during use should be considered at the design stage, and appropriate protection such as the installation of bollards or barriers should be considered for winerable areas, Design Method 9.2 Design of Symonite New Zealand Cladding System Installations is carried out by Chartered Professional Engineers, using technical information supplied by Syrmonite New Zealand Li. Durability Serviceable Life 10.1 When installed and maintained in accordance with the specifications and installation instructions as defined in the Technical Literatur, the Syronite New Zealand Cladding System, incorporating Symorite, Alucomat or Alcotex sheets, has an expected serviceable life of greater than 15 years, see Table 1 Table 1; Expected Serviceable ife of maintained Symonite New Zealand Cladding System in New Zealand. NZS 3604 [Zone ]Zone2 |Zone3 | Sea-Spray Corrosion ‘and Zone Zones 4 PVDF | Greater | Greater | Greater [15 years* 2eoat | than 15 |than15 | than 15 system on Jyears — |years | years ‘AASOO5- Hid PVDF [Greater | Greater [Greater | Greater coat than 15 |than15 |than15 | than 15 system on years |years [years | yearsa# ‘AASOO5- Hid + site specific conasion of the outer aluminium cladng may occur if not rmainainas to @ high level 4 Maintenance wil be requires 10.2 Some dark colours of PVDF coatings may experience some fading after prolonged UV exposure. Maintenance 10.3 Regular maintenance is essential for Symonite New Zealand Cladding System installations to maximise the serviceable life of the system. 10.4 An inspection of Symonite New Zealand Cladding System installations should be undertaken at least annually to determine the condition of the whole building, Items to be checked include, but are not limited to: + Dirt - any accumulation of dirt should be washed from the surface of the panels. + Scratches and dents — these need to be identified and repaired, + Joint sealant ~ identify any failures and repair. Control of External Fire Spread Symonite Panels 11.1 Symonite phenolic resin cored panels havea performance level ‘A’ in accordance with NZBC Acceptable Solution C/AS1 Table 7.5. The Symonite New Zealand Cladding System incorporating Symonite phenolic resin cored panels is suitable for use as an external wall cladding system on buildings in all purpose groups at any distance from the relevant boundary. 2011-1617, Alucomat and Alcotex Panels 11.2. When Alucomat and Alcotex panels are incorporated in the Symonite New Zealand Cladding System, itis considered to meet the performance requirements of NZBC Clause C3.3.5 for se as an external wall cladding when restricted to: ‘+ Single storey buildings 1 metre or more from the relevant boundary forall purpose groups; or, + Buildings with a building height up to 7 metres, 1 metre lor more from the relevant boundary, for all purpose groups ‘other than SC and SD; or, ‘+ Fully sprinklered buildings in accordance with NZS 4541 or NZS 4515 (as applicable) with a building height of up to 25 ‘metres, 1 metre or more from the relevant boundary forall purpose groups other than SC, SD, SA and SR. External Moisture 12.1 The Symonite New Zealand Cladding System has been tested in accordance with the requirements of AS/NZS 4284. This test method is designed to verity the performance of commercial building facades. 12.2 The design of the Symonite New Zealand Cladding System is subject to the following restrictions: + Drainage and compartmentalisation of the cladding system ‘must be atthe first level down from the top of the building, and every second level after that, or every 10 m, whichever is the lesser. + Vertical compartmentalisation with airtightness exceeding 0.1 MNsm? is required of the cladding cavity within 500 mm of every comer, at 2m centres after that, to a ‘maximum of 5 m centres where cladding panels are located further than 2.5 m from any edge of the cladding, or areas where alr flows are interrupted. + A building with wind exposure of less than 1.1 KPa ULS ‘must have a building wrap complying with NZBC Clause EQ/AS] Table 23, or a righ air barrie. + A building with any exposure to wind above a 1.1 KPa ULS ‘must have building wrap or 2 rigid air barrier (RAB) that has an airflow resistance of greater than 0.1 MNsji. + Abbuilding with exposure to wind on any part of its fagade above a 1.55 kPa ULS must use @ RAB as the backing for a cavity + A competent weathertightness specialist must design all Cladding penetration details for each project. 12.3 The Symonite New Zealand Cladding System when instaled in accordance with this Appraisal and the Technical Literature, prevents the penetration of moisture that could cause ‘undue dampness or damage to building elements, 12.4 The cavity must be sealed olf from the roof, inter-loor ‘and sub-floor spaces 10 meet code compliance with NZBC Clause €2.3.5. 12.5 The Symonite New Zealand Cladding System allows excess moisture present at the completion of construction to be dissipated without permanent damage to building elements to meet code compliance with NZBC Clause E2.3.6. 12.6 The details glven in the Technical Literature for weather sealing are based on the design principle of a drained ‘and ventilated cladding to prevent moisture entry for all joints, penetrations and junctions. Weathertightness details that are ‘developed by the designer are outside the scope ofthis Appraisal ‘and are the responsibilty of the designer for compliance with the NZBC, 12.7 Theuse of The Symonite New Zealand Cladding System wihere there is a designed cavity drainage path for moisture that penetrates the cladding, does not reduce the requirement for junctions and penetrations to remain weather resistant. General 13.1 Installation must be in accordance with the Symonite New Zealand Cladding System Technical Literature. 13.2 For inspection, reference must be made to the specific building design documentation and Symonite New Zealand Lia's installation information. Tests 14.1 Aweathertigntness test on the Symonite New Zealand Cladding System was performed at an IANZ accredited laboratory in accordance with AS/NZS 4284, in the presence of BRANZ commercial building weathertightness staff. The testing assessed the performance of the window head, jamb and sill details, compartmentalised vertical joint, drained horizontal joint, sttfener, internal and external comers and terminations. In addition to the weathertightness test, the details contained within the Technical Literature have been reviewed, and an opinion has been given by BRANZ technical experts that the details above will meet the performance requirements of the New Zealand Building Code External Moisture Clause E2, Third Edition June 2004, wren used within the scope ofthis Appraisal up to a ULS of 2.5 kPa Other Investigations 1.1 The Symonite New Zealand Cladding System Technical Literature has been reviewed by BRANZ and found to be satisfactory, 15,2. Site visits were carried out to assess the practicability of installation, and to examine completed installations. 15.3 Opinions on structural, weathertightness and durability aspects were given by BRANZ technical experts, 15.4 An assessment of the test method and results of fire testing carried out on Symonite panels has been made by BRANZ technical experts and an opinion given. 2011-1617, Quality 16.1 The manufacture of the Symonite sheets by Symonite Australia has not been examined by BRANZ, but the quality Control systems of Symonite Australia have been assessed by BRANZ and found to be suitable. 16.2 The manufacture of the Alucomat sheets by Jyi Shyang Industrial Co. Ltd has not been examined by BRANZ, but the quality control systems of Jyi Shyang Industrial Co. Ltd have been assessed and registered as meeting the requirements of 180 9001: 2000 by SGS, certicate TW03/015780A 16.3 The manufacture of Alcotex sheets by Dae Myung, Hwa Sung Co., Ltd has not been examined by BRANZ, but the quality control systems of Dae Myung Hwa Sung Co., Ltd nave been assessed and registered as meeting the requirements of ISO 9001 by the Korean Standards Association, Certificate QMs-1381 16.4 The processes and control used in the manufacture of cladding panels from Symonite and Alucomat sheet by Symonite New Zealand Ltd have been examined by BRANZ and found to be satisfactory 16.5 Symonite New Zealand Lid is responsible for the quality of product supplied. 16.6 Quality of panel installation onsite is the responsibility cof Symonite New Zealand Ltd 16.7 Designers are responsible for the building design, including structural design of the panels and fixings, and weathertightness design of penetrations, 16.8 Building owners are responsible for the maintenance of the Symonite New Zealand Cladding System in accordance with the instructions of Symonite New Zealand Ltd. Sources of Information = ASINZS 1170: 2002 Structural design actions. + AS/NZS 4284: 1995 Testing of building facades. + NZS 3602; 2003 Timber and wood-based products for use in building, + NZS 4515: 2003 Fire sprinkler systems for residential occupancies. + NZS 4541; 2008 Automatic fire sprinkler systems. * Compliance Document for New Zealand Building Code External Moisture Clause E2, Department of Building and Housing, Third Esition, July 2005. + New Zealand Building Code Handbook and Approved Documents, Building Industry Authority, 1992. + The Building Regulations 1992, up to, and including October 2004 Amendment S23 2011-1617 ‘Amendment No. 1, dated 2 April 2009. This Appraisal has been amended to update 1170. ‘Amendment No. 2, dated 17 November 2009. This Appraisal has been amended to incorporate a new sheet material and sealant and to update the pictures. reference from NZS 42 BRANZ In the opinion of BRANZ, The Symonite New Zealand Cladding System is fit for purpose and will comply with the Building Code to the extent specified in this Appraisal provided it is used, designed, installed and ined as set out in this Appraisal. ‘The Appraisal is issued only to Symonite New Zealand Ltd, and is valid until further notice, subject to the Conditions of Appraisal. a » ” > @ Conditions of Appraisal This Aspras rates only fo the product as dexrbed her, rust be rea, considered and used in fll together wth the echrial erate; oes not address any Legislation, Regulations, Codes or Standards, nol special named herein; |S copyright of BRANZ. Symone New Zealand Lic certiuos fo Rave the peduct viewed by BRANZ) hall oily BRANZ of any changes in Drsuetsprcfisten or quay assurance Imessures per 10 the product beng snarete, ‘sbiesy the BRANZ Appraisals Services “es and Conatons. Warrants that the product andthe ‘manufacturing pecass fo the product are ‘mantained ator above te standars, eels ‘nc qual assesod and found satisfactory by BRANZ pursuant to BRANZ's Apprasl othe product BRANZ makes no representation or warranty a ‘enatve otlcivua examples batches of or ndvialinstalations of he peduct, Incidng methods and womans: the presence or absence of any part or ‘iat its subsisting inthe product or ny athe product my Bares ot waranty fed by 2ry referers otis Appa to any oer publication sal be read 38a rlerercs to {he version ofthe publication specie in this Appraisal BRANZprovdesaoceristion, puarartee, indemnity 0° waranty, 19 Symone New Talon Ut er any thie pary. For BRANZ t ar P Robeltson Chief Executive Date of issue: 31 July 2006 | Sa a meee | ee FA | 5 1 | 5 ee * | Bee tA oman renee @ Toe ce “This datas vall wend ee 4 Mpmmemenem — UnderFieslnig os Pery a ee eee ae a =H one enon nen a \: x z 4 om Ih Fin deanee Ponts (3) Alucobond panel detail re Alucobond panel detail2 Alucobond panel detail3 - vertical junction ST SST 132 CRETER. SUIMONITE SHEET 1.0 (2)) Renter ‘> Alucobond-precast junction Ore Rake sHmomiTe SHEET &) © 1 ‘no meena na SoS sm seein jes [st >> Plan & Elevation of Nose Structure. > Alucobond Gable End ; | ee Or REFEe SSWONIE Sheer 4.1 C142) DESIGNED | Riwm Cc ‘DATE oH my | frokkorme - - [NOTE = — re toe =a a ae OTAGO SETTLER'S MUSEUM smrmas | 'A64 05 2 cr 7 DUNEDIN CITY “SAL VERY AL - ibeRoo| ——— ; % = = Peoun cy STAGE ¢REDREL OPMENT (eon ere “aro FOR CONSTRUCTION 16.04.12 |+ —| Romar Tones ig == | ss | Isa anon oerA8.s AAOUND PFC Once ABOVE ENTIRE | | neta Paes Saran ae Siac eae Serre Pare = on 1) ee aaa —aa tl 4 Se | | Se See OS oe | fers tia tea | Cp See | (eee SE || aes sameeren | — =} @ FlushGlaze 100mm Window Head. | gases AND path to on reeaoaggmmaatrcice vemmre TT ae ‘ease ms aa an Oo i Stoo a FlushGlaze 150mm Window Head feeons won| one ' ) Owes ee ees a ‘ eras | WK on L ene a ee >» FlushGlaze 150mm Transom if Sesctetoame re Sts 5 - =e frau] ene pais Sao eee & Tl ze Barrimecrce ED pelt etee eat sae enaraman > Flushglaze Internal Corner eam eu Se cee ores eer ea ew Pc rarree ps 3 | | Amended Plan and/or aera | SSSaeeasaescecees | | | / FlushGlaze 100mm Sill CS sarrreaiceceerrantceerruneas an = me | OTAGO SETTLERS MUSEUM era aie eennanneprm—eemnemneenl a STAGE 4 REDEVELOPMENT emo - cow Dera. FOR CONSTRUCTION 11.11.11 = ROBERT TONGUE FNZIA ALUMINIUM COMPOSITE CLADDING SYSTEM TYPICAL DETAILS CONTENTS 1.0 TYPICAL VERTICAL JOINT/ EXT. CORNER 20 TYPICAL HORIZONTAL JOINT 30 LIGHT COMMERCIAL HEAD & SILL DETAIL 3.1 LIGHT COMMERCIAL OPEN HEAD & JAMB DETAIL 52 RESIDENTIAL HEAD & SILL DETAIL 33 RESIDENTIAL JAMB DETAIL 34 COMMERGIAL HEAD & SILL DETAR. 2:5 COMMERCIAL JAMB DETAIL 40 FASCIADETAL- SOFFIT BY OTHERS 44 PARAPET 8 SOFFIT DETAIL 42. SOFFITORIP EDGE DETALS 43. PARAPET WITH MINIMAL UPSTAND 50 BASEDETAL 54 BASEDETAIL 52 TYPICAL EYEBROW SILL DETAL 53 TYPICAL UPSTAND DETAIL 80 TYPICAL INTERNAL CORNER 6.4 FIBRE CEMENT INTERNAL CORNER, 62 VERTICAL PROFILED METAL INTERNAL CORNER, 63 HORIZONTAL PROFILED METAL INTERNAL CORNER 7.0 TYPICAL WALL / SOFFIT BY OTHERS 7.4 TYPICAL WALL / RAKING SOFFIT JUNCTION 7.2 WALL SOFFIT JUNCTION & DOWNPIPE PENETRATION 80 PRECAST CONCRETE WALL JUNCTION 8.1 PRECAST CONCRETE WALL JUNCTION 90 VERTICAL PROFILED METAL JUNCTION Framing note: Timber faring by thers i o be at 600 centers max for both studs & nogs. This may be required a closer centers subject to engineering requirement. Rigid alr barrier note: As per Symonte Branz Appraisal #528 section 122A buildin with exposure to wind on any part of ts facade above 1.55 kPa ULS must use a RAB as backing fr the caviy. ti he bulng designers responsibly to determine wind loading on the building and incorporate RAB into the detaling as required tothe specficatons ofthe RAB manufacturer. Cavity Battens are ot require withthe Symerite Now Zealand cavity system as a cavity I formed between the fking angles and Suctur with high impact paste packers (1 packers). Nominal cally death is 40mm trom structure to outer face of pane. n ‘some situations {when interfacing with residential joinery profes) tis cavity is may be deeper. Any instance where cavity is pushes beyond 60mm may requie the installation of 20mm cavily battens by others. YORE TEOHIMTOALGRAVIINGS 207: © SVONTE NEW ZEALAND LNTED 00 ‘Ranoal specication suet change wo pao natoe . ‘ 2011-1617,.4 1 WeW TERLAND) CLEATS AT PANEL FOLDS (Facron’ Fite) a 4 +H ge BREATHER TYPE BUILOING PAPER On TINDER FRAMING BY OTHERS ——— ALUCOMAT® PANEL BY SyHONTTE tick mpacT PLASTIC PACKERS BY SYHONITE | TyPICAL CORNER : wen ] | b | BREATHER TYPE BUILING PAPER | ON TMBER FRAMING BY OTFERS 11 | ALUMINIUM FRING ANGLES BY SYVONTE ee ay omens — - SEALANT ON PEE | | ROD BY SYMONITE TvPIcAL VERTICAL JOMT 2eM NOTE: TINGER FRAWING BY OTHERS TOBE AT 600 (CTRS MAX FOR BOTH STUDS & NOGS, MAY BE REQUIRED AT CLOSER CENTERS SUB.ECT TO ENGINEERING REQUIREMENTS S¥ONITE TECHNICAL DRAWINGS 202; © SYMONTE NEW 2EAANDLTED SSS “Technical specification subject to change without prior noice ALUMINIUM COMPOSITE CLADDING SYSTEM ALUCOMAT® PANEL BY SYMONITE HIGH IMPACT PLASTIC. PACKERS BY SYMONITE ALUMINIUM FIXING ANGLES. BY SYMONITE \ti SEALANT ON PEF ROD BY SYMONITE BUILDING PAPER ON TIMBER FRAMING BY OTHERS ‘TYPICAL HORIZONTAL JOINT 26M NOTE: TIMBER FRAMING BY OTHERS TO BE AT 600 ‘CTRS MAX FOR BOTH STUDS & NOGS. MAY BE REQUIRED AT CLOSER CENTERS SUBJECT TO ENGINEERING REQUIREMENTS ie BY OTHERS. ‘SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without prior notice 2.0 ALUMINIUM COMPOSITE CLADDING SYSTEM BUILDING PAPER ON TIMBER FRAMING BY OTHERS ALUCOMAT® PANEL ‘BY SYMONITE BUILDING PAPER LAPPED OVER HEAD FLASHING BY OTHERS, HEAD FLASHING BY JOINERY COMPANY AL. FIXING ANGLE & SEALANT ON PEF ROD BY SYMONITE, MM ORAINHOLE WITH GROMMETS JOINERY BY OTHERS. JOINERY SEALED TO PANEL BY SYMONITE 09MM AL. BACKFOLD ‘SUPPORT FACTORY FITTED CLEATS ‘AT PANEL FOLDS. 'SOAKERS AT PANEL JOINTS BY SYMONITE BUILDING PAPER ON TIMBER FRAMING BY OTHERS 2011-1617,+ T ) “an | vats 7 — Gis ey oTHERS Min, PANEL J OVERLAP TO 2 SOINERY ‘SUBCONTRACTOR IMPORTANT: ENSURE 164M MIN, CLEARANCE FROM INSIDE OF SILL TRAY ‘TO FLASHING TAPE, FOR PANEL UPSTAND }_— oie ey OTHERS. | seo | VARIES SILL DETAIL (LIGHT COMMERCIAL) OM ‘SYMONTE TECHNICAL DRAVINGS 2072 SYMONTTE NEWZEALANDUMTED———S~S Tethneal speceton suet Senge wnt por notes : ALUMINIUM COMPOSITE CLADDING SYSTEM BUILDING PAPER ON TIMBER FRAMING BY OTHERS, ALUCOMAT® PANEL BY SYMONITE HEAD FLASHING BY JOINERY COMPANY 16X16WM CONT. BLACK POWDERCOATED ALI ANGLE WITH VISIBLE SS yyy, pane FIXINGS @ 600 CTRS. OVERLAP TO JOINERY SMM DRAINHOLE. WITH GROMMETS JOINERY BY OTHERS \ AL. FIKING ANGLE & SEALANT i JAMB DETAIL (LIGHT COMMERCIAL) 12@M 'SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without prior notice ON PEF ROO BY SYMONITE Gib By OTHERS — ALUCOMAT® PANEL, BY SYMONITE, ~ BUILDING PAPER ON TIMBER FRAMING BY OTHERS. GIB BY OTHERS ALUMINIUM COMPOSITE CLADDING SYSTEM 2041-1647, Vy WeW TERLAND! STRAPPING BY OTHERS. MAY BE REQUIRED DEPENDING ON JOINERY PROFILE ALUCOMAT® PANEL BY SYMONITE HEAD FLASHING AND FLASHING TAPE BY OTHERS ‘4M FOLDED ACM PANEL FIXING LUGS BY SYMONITE AL. FIXING ANGLE \ BY SYMONITE vnupaner J SveRAP TO 2 SEY JOINERY BY OTHERS ~ MM DRAINHOLE WITH GROMMETS JOINERY SEALED TO : PANEL BY SYMONITE IMPORTANT: ENSURE 15MIN MIN. 09MM AL. BACKFOLD ‘SUPPORT FACTORY FITTED CLEATS ‘AT PANEL FOLDS. SOAKERS AT PANEL + JOINTS BY SYMONITE Tk HIGH IMPACT PLASTIC = PACKERS BY SYMONITE TY — BUILDING PAPER ON TIMBER FRAMING BY OTHERS ip By OTHERS FLASHING TAPE, PACKING & AIR SEAL BY OTHERS, FLASHING TAPE, PACKING & AIR SEAL BY OTHERS |_ CLEARANCE FROM INSIDE OF SILL TRAY ‘TO FLASHING TAPE, FOR PANEL UPSTAND ——— BUILDING PAPER ON TIMBER FRAMIN BY OTHERS. — STRAPPING BY OTHERS MAY BE REQUIRED DEPENDING SILL DETAIL (RESIDENTIAL JOINERY) 12@M ON JOINERY PROFILE SYMONITE TEGHNIGAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without prior notice 3.2 ) ALUMINIUM COMPOSITE CLADDING SYSTEM [STRAPPING BY OTHERS MAY BE REQUIRED DEPENDING ON JOINERY PROFILE ALUCOMAT® PANEL BY SYMONITE HEAD FLASHING AND FLASHING TAPE BY OTHERS. AL, FIXING ANGLE BY SYMONITE snc eaner sunt oRANHOLE — / 2 JOINERY BY OTHERS AL. FIXING ANGLE &@ —— SEALANT ON PEF ROD. BY SYMONITE JOINERY BY OTHERS FLASHING TAPE, PACKING. AND AIR SEAL BY OTHERS, ie EW TERUAND _—— auitoine PAPER ‘ON TIMBER FRAMING BY OTHERS GB BY OTHERS \__ FLasuine Tape, PACKING & AIR SEAL BY OTHERS, (2) ean vevan oPrion 2 (RESIDENTIAL JONERY) 12@ AE JAMB DETAIL (RESIDENTIAL JOINERY) 12@M ‘SYMONITE TECHNICAL DRAWINGS 2012; © SYMONITE NEW ZEALAND LIMITED “Tecnncal specification subject to change without pror notice ALUCOMAT® PANEL BY ‘SYMONITE ‘STRAPPING (BY OTHERS) MAY BE REQUIRED DEPENDING ON JOINERY PROFILE BUILDING PAPER BY OTHERS TIMBER FRAMING BY OTHERS, iB BY OTHERS. 3.3 2011-1617,_% BUILDING PAPER ON TIMBER FRAMING BY OTHERS hoo | varies ALUCOMAT® PANEL. BY SYMONITE BUILDING PAPER LAPPED OVER HEAD FLASHING BY OTHERS. HEAD FLASHING BY JOINERY COMPANY ACM LUGS BY SYMONITE 16x16¥M CONT. BLACK POWDERCOATED AL 7 ANGLE WITH VISIBLE SS. FIXINGS @ 600 CTRS Min, PANEL OVERLAPTO JOINERY MM DRAINHOLE ~ [5 wn WITH GROMMETS JOINERY, PACKING, AIR ‘SEALS FLEX. FLASHING TAPE ALL BY OTHERS TyPI JOINERY, PACKING, AIR SEALS FLEX. FLASHING. TAPE ALL BY OTHERS JOINERY SEALED TO PANEL BY SYMONITE O.9NM AL. BACKFOLD ‘SUPPORT FACTORY FITTED CLEATS ‘AT PANEL FOLDS [SOAKERS AT PANEL JOINTS BY SYMONITE BUILDING PAPER ON TIMBER FRAMING BY OTHERS TYPICAL COMMERCIAL SILLDETAIL 5 7@M IMPORTANT: ENSURE 15MM MIN SLEARANCE FROMINSEOFSLLTRAY | { = II TO FLASHING TAPE, FOR PANEL UPSTAND SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED “Technical specification subject to change without prior notice 3.4 AL. FIXING ANGLE 8 —— SEALANT ON PEF ROD. BY SYMONTE JOINERY, PACKING, AIR. SEALS FLEX. FLASHING TAPE ALL BY OTHERS ALUMINIUM COMPOSITE CLADDING SYSTEM A WEW TEALAND| ALUCOMAT® PANEL BY SYMONITE 154MM PANEL COVER TOVOWERY BUILDING PAPER ON TIMBER PRAMING BY \ yas omens \ min C 7D) TYPICAL COMMERCIAL JAMB DETAIL - 12@M 'SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED 35 “Technical specification subject to change without prior notice 2011-1647. 2011-1647 # A WEN TEACAND ALUMINIUM COMPOSITE CLADDING SYSTEM —— UNDERFLASHING ATONTS BY ArPANeLrows = Be : ALUCOMAT® PANEL 8 BY SYMONTTE z z suLoIG PAPER ON — |_______] ater TIMBER FRAMING BY I HHovES Sov FROM OTHERS } PANEL ENDS ai 23 — wemarane on purer oTreRs ich MpacT PLASTIC PACKERS OY SYMONE x te ‘SOFFIT BY ag omens : je | eran ante sn DRABHOLE 3 Sseauanton wit GROMMETS pernoo er SYWONITE S¥ANONITE TECHNICAL ORAWINGS 2012: SYMONITE NEW ZEALAND UTED 4.0 Technical specification subject to change without prior notice ALUMINIUM COMPOSITE CLADDING SYSTEM FACTOR FITTED CLEATS ‘AT PANEL FOLDS. HIGH IMPACT PLASTIC PACKERS BY SYMONITE BUILDING PAPER ON TIMBER FRAMING BY OTHERS ALUCOMAT® PANEL. BY SYMONITE 2011-16172" UNDERFLASHING AT JOINTS BY ‘SYMONITE [APRON FLASHING By OTHERS, TAKEN UP OVER PARAPET FRAMING MM DRAINAGE HOLES 50MM FROM PANEL ENDS — ROOF CLADDING BY OTHERS BUILDING PAPER ON TIMBER FRAMING BY OTHERS HIGH IMPACT PLASTIC ——] \ PACKERS BY SYMONITE tf WN awcowaroraner ——| /]|LMI < BY SYMONITE | i FACTOR FITTED CLEATS + + x ‘AT PANEL FOLDS te ae NN auworanHore ——-——“" 4 <2 WITH GROMMETS ‘AS REQUIRED +12. ACM FASCIA TO SOFFIT TOME AL FIKING ANGLE & SEALANT ON PEF ROD BY SYMONITE 'SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without pror notice 2011-1647 JE: BUILDING PAPER ON TIMBER FRAMING BY OTHERS. HIGH IMPACT PLASTIC PACKERS BY SYMONITE ALUCOMAT® PANEL BY SYMONITE FACTOR FITTED CLEATS ‘AT PANEL FOLDS. avenge ancte a SEALANT ON PEF ROD. | BY SYMONITE hey ‘MN DRAINHOLE WITH GROMMETS, ——As ReQuiED DRIP EDGE DETAIL 120M BUILDING PAPER ON TIMBER FRAMING BY OTHERS. HIGH IMPACT PLASTIC — PACKERS BY SYMONITE. ALUCOMAT® PANEL — BY SYMONITE FACTOR FITTED CLEATS + a $ s0M DIFFERENCE IN LEVEL FOR TOLERANCE / DRIP EDGE ‘MM DRAINHOLE vi eons \ texs64am conr. aLack, POWDERCOATED ALI ANGLE WITH VISIBLE SS FIXINGS @ 600 CTRS. OPEN FLUSH SOFFIT JOINT TOM 4.2 SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIM Technical specification subject to change without prior notice y ALUMINIUM COMPOSITE CLADDING SYSTEM 2011-1617. — screwenxine WITH SEALANT CONTINUOUS ACM, . PANEL CLOSER BY SYMONITE FACTOR FITTED CLEATS — ‘AT PANEL FOLDS, la g g S— sTaIiess STEEL ALUCOMAT® PANEL FIXINGS @ PANEL BY SYMONITE JOINTS MM DRAINAGE HOLES 50MM FROM HIGH iMPACT PANEL ENDS PLASTIC PACKERS MEMBRANE ON BY SYMONITE PLY BY OTHERS BUILDING PAPER ON TIMBER FRAMING BY OTHERS NOTE: FOR USE WITH LOW ROOF UPSTAND LAP ONLY (> panarer wars moans vesrano ¢ wen |__ TIMBER FRAMING BY OTHERS 'SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED “Technical specification subject to change without prior notice 4.3 2918: 1617..2: ike ew LEAUAND ALUMINIUM COMPOSITE CLADDING SYSTEM ALUCOMAT® PANEL ‘BY SYMONITE — GiB By OTHERS BUILDING PAPER ON TIMBER FRAMING BY OTHERS AL FIXING ANGLES 8 SYMONITE au DRAINAGE —— . HOLES «| NOTE: 300MM CLEARANCE + TO GROUND REQUIRED FOR. , g oO FIXING ACCESS, IF NOT EL |v avateasce, use veran 5. s “ ee CONCRETE SLAB BY OTHERS . oe [ADJACENT GROUND | eM. as, . | . . A. DETAIL @ BASE OF PANEL Wem SyAONITE TECHNVGAL DRAWINGS 2072; ©SYMONITE NEW ZEANDUMITED———SSOSSS*~«~O Tecmtal sucicaton sitet Carge whet po: notea ; ALUMINIUM COMPOSITE CLADDING SYSTEM ALUCOMAT® PANEL BY SYMONITE A EW TEALANE| > | — { 080 vagies TS j TIMBER FRAMING BY OTHERS. BUILDING PAPER LAPPED OVERCLOSER BY OTHERS FOLDED ACM CLOSER WITH PRE DRILLED DRAINAGE HOLES BY SYMONITE MM DRAINAGE HOLES SEALANT BED CONCRETE SLAB BY OTHERS ADJACENT GROUND > | 3 Le BE Lol |. 3 ‘suit Seat g a BASE DET/ 12@M iB BY OTHERS, ‘SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED “Technical specication subject to change without rir noice 5.1 ALUMINIUM COMPOSITE CLADDING SYSTEM JOINERY, PACKING, ‘AIR SEAL ALL BY OTHERS: PANEL SEALED TO SILL TRAY BY ‘SYMONITE O.9MBA AL. BACKFOLD SUPPORT BY SYMONITE HIGH IMPACT PLASTIC. —~ PACKERS AS. REQUIRED UNDERFLASHING @ PANEL JOINTS BY ‘SYMONITE UNDERFLASHING @ PANEL — JOINTS BY SYMONITE FACTORY FITTED CLEATS AT PANEL FOLDS HIGH mePaCT PLASTIC PACKERS AS REQUIRED ‘ACM PANEL BY ‘SYMONITE BREATHABLE BUILDING: 16MM MIN CLEARANCE AT SILL _ TRAY FOR PANEL UPSTAND 4 COMM MIN CLEARANCE FROM BOTTOM OF SILL TRAY LEG TO FRAMING PAPER OVER TIMBER. FRAMING ALL BY OTHERS SMM DRAINAGE HOLES WITH GROMMETS, 50 MM FROM PANEL ENDS. f 40 v [vom 300 MIN TO ADJACENT GROUND. FOR FIXING ACCESS AL. FIXING ANGLE BY ‘SYMONITE PRECAST CONCRETE —— BY OTHERS. AQUACENT — GROUND ¢ Nr EYEBROW SILL DETAIL @ - agit 1614, JOINERY, PACKING, IIR SEAL ALL BY OTHERS. _SYMONITE TECHNICAL DRAWINGS 2072: © SYMONITE NEW ZEALAND LIMITED “Technical specification subject to change without peor notice 5.2 ALUMINIUM COMPOSITE CLADDING SYSTEM ‘ON PEF ROD BY SYMONITE, UNDERFLASHING @ PANEL JOINTS BY SYMONITE (Ge TYPICAL UNDERFLASHING DETAIL OD wen HIGH IMPACT PLASTIC PACKERS AS REQUIRED ‘ACM PANEL BY — SYMONTTE 2 AL. FIXING ANGLE & SEALANT é (ON PEF ROD BY SYMONITE. NS 8 UNDERFLASHING @ PANEL ee soa JOINTS BY SYMONITE \ oN maaro BREATHABLE BUILDING —§ —— PAPER OVER PLY [TIMBER FRAMING ALL BY OTHERS. eacrorvemmen — 2 CieaToarPane. | Fotos 7 ynii' 1647 Vy ew TEALANO| AL. FUKING ANGLE & SEALANT —|— breATHABLE BUILDING PAPER OVER PLY / TIMBER FRAMING ALL BY OTHERS, : 4 als TYPICAL UPSTAND DETAIL TOM ‘SYMONITE TECHNICAL DRAWINGS 2072: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without prior notice 5.3 aod ALUMINIUM COMPOSITE CLADDING SYSTEM i WEW TEAUAND jy GIB BY OTHERS. \ VV HIGH Impact PLasTic —/ PACKERS AS REQUIRED AL. FIXING ANGLE, HIGH IMPACT PLASTIC PACKER, & SEALANT ON BACKING ROO BY SYMONITE INTERNAL CORNER BACK — FLASHING BY OTHERS BUILDING PAPER ON TIMBER ~ FRAMING BY OTHERS ALUCOMAT® PANEL BY ‘SYMONITE | | TYPICAL INTERNAL CORNER TOM ‘SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED 6.0 “echnical specication subject to change without pir notice agit 16 t! was ALUMINIUM COMPOSITE CLADDING SYSTEM /-—— 618 BY OTHERS / FIBRE CEMENT SHEET —/ BY OTHERS: AL FIXING ANGLE. & SEALANT ON BACKING ROD BY SYNOMITE INTERNAL CORNER BACK —______/ | FLASHING BY OTHERS. BUILDING PAPER ON TIMBER FRAMING BY OTHERS ALUCOMATO PANEL BY SYMONE CORVER FARE CEMENT JUNTON an SHWORTTE TEOIWICAL ORAVONGS 07 @ SONTE NAW ZEA AND UNITED é4 Technical specification subject to change without prior notice @oricigay, ALUMINIUM COMPOSITE CLADDING SYSTEM yr GIB BY OTHERS: { avucomat® PANEL BY SYMONITE \____ aL. FIXING ANGLE & SEALANT ON BACKING ROD BY SYMONITE BREATHABLE BUILDING PAPER ON TIMER FRAMING ALL BY OTHERS. VERTICAL PROFILED METAL CLADDING BY OTHERS, — FLASHING By OTHERS NAMA. XA INTERNAL CORNER / VERTICAL PROFILED METAL JUNTION Co pitas coment venneas Prom aera 20M YWONITE TECHNICAL ORAMIINGS 207, © SYMONITE NEW ZEALAND UNITED 62 ‘Technical specification subject to change without prior notice . Vie WOW TEAURND ALUMINIUM COMPOSITE CLADDING SYSTEM /— Gite ey OTHERS. / HORIZONTAL PROFILED METAL CLADDING BY OTHERS COMPRESSIBLE FOAM SEAL BY OTHERS / AL. FIXING ANGLE, & SEALANT. —/ ‘ON BACKING ROD BY SYMONITE (CORNER FLASHING 7 BY OTHERS ALUCOMAT® PANEL BY SYMONITE BREATHABLE BUILDING PAPER ON — ee | _ TIMBER FRAMING ALL BY OTHERS ey INTERNAL CORNER / HORIZONTAL PROFILED METAL JUNTION : T2@AG : YUONITE TEGHNOAL DRAWINGS 2072, © AONE NEW ZEALAND UNITED 63 Teta! pecieton set change wo pr oe : 2ott-i647,. ALUMINIUM COMPOSITE CLADDING SYSTEM SOFFIT LINING BY OTHERS AL FIXING ANGLE, & SEALANT ON BACKING ROD BY SYMONITE. ALUCOMAT® PANEL BY SYMONITE EREATHABLE BUILDING PAPER ON. TIMBER FRAMING ALL BY OTHERS ‘TYPICAL WALL / SOFFIT JUNCTION TOA SYMONITE TECHNICAL ORAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED 7.0 ‘Tochnical specification subject to change without prior notice . wt ALUMINIUM COMPOSITE CLADDING SYSTEM rr SOFFIT LINING INSTALLED AFTER —/ [ACM PANEL BY OTHERS FLASHING BY OTHERS. FIXING ANGLE BY SYMONITE ALUCOMAT® PANEL BY SYMONITE TIMBER FRAMING ALL BY OTHERS BREATHABLE BUILDING PAPER ON | 40,60 VARIES | — | ! ! ne | WALL / RAKING SOFFIT JUNCTION - OPTION 1 TOA SOFFIT LINING —/ BY OTHERS, AL-FIKING ANGLE, & SEALANT —“~ ON BACKING ROD BY SYMONITE, ALUCOMAT® PANEL —— BY SYMONITE BREATHABLE BUILDING PAPER ON — TIMBER FRAMING ALL BY OTHERS. WALL RAKING SOFFIT JUNCTION - OPTION 2 T2@ As SYMONITE TECHNIGAL ORAWINGS 2012: ‘© SYMONITE NEW ZEALAND LIMITED TA “Technieal specication subject to change without prior notice ALUMINIUM COMPOSITE CLADDING SYSTEM A EW ERLANG] SOFFIT FRAMING TOBE AT 4s0Mnt CTRS MAX PENETRATIONTO — ‘BE CUT AROUND, ‘ON SITE AND. COVE SEALED BY ‘SYMONITE DOWNPIPE OR ——4 OVERFLOW BY OTHERS AL. FIXING ANGLE & 1 ‘SEALANT ON PEF ROD BY SYMONITE. ‘ACM PANEL BY ‘SYMONITE BREATHABLE BUILDING PAPER OVER TIMBER FRAMING ALL BY OTHERS (wats 1 sort JUNCTION & DOWNPIPE PENETRATION TOR ‘SYMONITE TECHNICAL DRAWINGS 2072: © SYMONITE NEW ZEALAND LIMITED 72 “Technical specication subject te change without prior notice . ALUMINIUM COMPOSITE CLADDING SYSTEM a fil AME ip BY OTHERS 7 " .po 4 : “TIGER FRAMING PRE CASTCONcRETE ———} <> By OTHERS WALL BY OTHERS 5 2 SCREW FIXING WITH we 7 NYLON PLUGS . — suiLoine PAPER BY OTHERS sige IMPACT PLASTIC PACKERS. BY SYMONTTE AL. FIXING ANGLE & SEALANT ON BACKING ROD BY SYMONTE ALUCOMAT® PANEL BY SYMONITE DETAIL AT PRE CAST CONCRETE WALL 72@M 8.0 ‘SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED ‘Technical specification subject to change without prior notice PRECAST CONCRETE ALUMINIUM COMPOSITE CLADDING SYSTEM WALL BY OTHERS 2011-1647 1 Wew TEAL AND) — GIB BY OTHERS BUILDING PAPER ON TIMBER FRAMING BY OTHERS BACK FLASHING SEALED TO NOTE: CHASED FLASHING IS RECOMMENDED AT ALL. VERTICAL CONCRETE JUNCTION DETAILS. 1S THE BUILDING DESIGNERS RESPONSIBILITY TO CHECK WITH APPLICABLE LOCAL BUILDING AUTHORITY AS TO WHETHER THIS IS REQUIRED DETAIL AT PRE CAST CONCRETE WALL 12@Mt ‘SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED ‘Technical specication subject to change without prior notice SAWCUT CHASE BY OTHERS. (RECOMMENDED) ALUCOMAT® PANEL. BY SYMONITE —— AL. FIXING ANGLE & SEALANT ‘ON BACKING ROD BY SYMONE 8.1 ALUMINIUM COMPOSITE CLADDING SYSTEM 4060 VARIES { \ i iB. ~ BY OTHERS | TIMBER FRAMING ——|—-| BY OTHERS. VERTICAL PROFILED METAL JUNCTION 5 12@A4 2011-1617, = Vey WEW LERURNO! ALUCOMAT® PANEL BY SYMONITE AL. FIXING ANGLE & ‘SEALANT ON BACKING ROD BY SYMONITE ‘COLORSTEEL FLASHING BY OTHERS, PRIOR TO INSTALLATION OF ACM, ‘COLOUR STEEL CLADDING ON BREATHER TYPE. BUILDING PAPER ON WALL. FRAMING ALL BY OTHERS 'SYMONITE TECHNICAL DRAWINGS 2012: © SYMONITE NEW ZEALAND LIMITED Technical specification subject to change without prior notice

You might also like