You are on page 1of 120

LIMITLESS

POSSIBILITIES
Incredibly Reliable, Easy to Use, and Powerful!

Discover the limitless possibilities of GA700!

SUSTAINABLE FLEXIBLE

With a flexible motor control, power-


ful and extendable functionality, and
Connectivity
C ty
Advan
Advanced Motor Control the GA700 is the drive of choice for
Customizable almost any task, ranging from simple
transportation, presses and others up
Quick and Easy Setup to complex systems with network con-
Easy Installation nected drives or the demand for higher
levels of safety.
Functional Safety
Equally impressive to its robust, pow-
Global Certified
erful, and flexible design are innova-
Environmental Protection tive features like the tuning-less vector
control, the haptic keypad with guided
configuration and DriveWizard Mobile,
the app for smart phones and tablets.

Combine all this with modern safety


features and a variety of environmental
EASY solutions, and you will need to look no
further than GA700 for all your variable
speed needs.
OUR Effortless Network Integration
• Supports all major networks with a
new cost effective network integration

COMMITMENT
feature
• Maintain network communications
even during loss of main input power

TO YOU
One for All
• Precise and tuning-less motor control
with one drive controlling any induc-
tion, permanent magnet or synchro-
nous reluctance motor

Quick & Easy Set-up


• Reduce set-up time with an intuitive
keypad, navigation and start-up
wizards

Convenient Set-up
and Monitoring
• Safe programming without main power
connected
• Cloud-connected DriveWizard Mobile
app for drive management on smart-
phones and tablets.

Powerful Configuration Tools


• DriveWizard ® and DriveWorksEZ ® are
PC tools for drive management and
logic programming
• DriveWizard for drive management,
start-up and failure analysis
• DriveWorksEZ for extending
functionality by logic programming

Integrated Functional
Flexibility, ease of use and a sustainable Safety
• Increased safety and reliability
design for the best value proposition in with STO SIL3 functional safety

your application Meets Global Standards


• Local/global standards
• RoHS compliant

Flexible Package Design


• Designed with flexibility to simplify
installation and cabinet design
Effortless
network integration
GA700 drives support all the major industrial communications and connection
topologies (ring, star, line, etc.) to adapt to various factory automation
networks. Reduce wiring when connecting to an upper level controller or PLC
through available built-in protocols and/or dedicated communication options.

Network integration
benefits/features:
PLC Easy integration into your network
• Supports all major networks and topologies
• Network compliance tested
• Network up to 5 drives with a single com-
munication card

Cost savings with built-in protocols


ONE FIELD BUS OPTION CARD TO NETWORK 5 DRIVES
• RS-485 MEMOBUS/Modbus protocol
• 115.2 kbps communication speeds

Keep control during main power loss


• Embedded +24VDC input control power
standard
• Programming and monitoring without
main power

RS485

Cost Effective Integration Embedded +24VDC Input


Up to five GA700 drives can be ac- When supplying the GA700 through
cessed through only one fieldbus op- the built in 24 Vdc control power input,
tion card, thus providing a cost effec- network communications can be main-
tive solution with reduced wiring effort. tained even during main power loss,
thus allowing continuous monitoring
and faster start up on power recovery.
SUSTAINABLE FLEXIBLE

One for all EASY

The GA700 precisely controls induction, permanent magnet, and synchronous


reluctance motors providing versatility to run a variety of applications
with just one drive. The times of complex motor set-up are over. With the
new EZ vector mode, the GA700 can run all of these motor types without
comprehensive tuning.

Motor control
benefits/features:
INDUCTION Flexible Motor Control
MOTORS INTERIOR • Tuning-less with EZ vector
PERMANENT • Open/closed loop speed or torque
MAGNET control/synchronous reluctance
motors
• Induction/permanent magnet
SURFACE motors
PERMANENT
• 590 Hz output frequency *
MAGNET
• Zero speed control without encoder

Energy savings
SYNCHRO-
• Automatic energy efficiency
NOUS optimization function
RELUCTANCE

100
2 % IMPROVEMENT FOR PM MOTORS
90 Maximum Efficiency
80 By introducing motor speed control as a re-
placement of gears, valves or dampers the
70 GA700 unlocks great energy saving potential
Efficiency [%]

60 in various applications. In addition the it auto-


6 % INCREASE FOR INDUCTION
50 matically optimizes the motor efficiency for any
MOTORS AT 20 % SPEED
speed and load condition and so minimizes
40 overall losses.
GA700
30 WITHOUT OPTIMIZATION
GA700 lowers energy cost by running your ap-
20
0 20 40 60 80 100 plication at maximum efficiency.
Speed [%]

* Depends on Control Method


Quick & easy
set-up
The GA700 provides a user programming experience with an intuitively-
designed keypad and tactile user interface. Self-guiding navigation menus and
start-up wizards make the programming and set-up faster and easier than ever.
No manual? No problem. With DriveWizard Mobile the GA700 can easily be
managed and controlled from your smartphone or tablet. Parameter and failure
code description including including troubleshooting assistance are integrated.

Mobile Device Connectivity


Mobile device connectivity is achieved through using the built-in USB port or
wireless communication with the Bluetooth® LCD keypad option.

1. Bluetooth keypad optional


2. Supports Android
SUSTAINABLE FLEXIBLE

EASY

Keypad
Copy Function benefits/features:
Multiple sets of param-
eters can be stored Reduce set-up time
and easily transferred
(copied) to additional • Start-up wizard
drives • Favorite parameter/monitor
Micro SD Storage function
Micro SD for data • Copy function integrated into
logging storage the keypad
• Parameter set is backward
compatible with previous gener-
Hi-Resolution Display ation drive products
• Fast navigation
Contrast control offers
• Help function
clear and readable full-
text descriptions
Drive parameter management
Real-Time Clock • Storage of up to 4 drive
Real-time clock for parameter sets
time stamp of fault • Data logging with real time
information (battery stamp e.g. for fault analysis,
compartment load profile analysis etc. (up to
Automatic Backup
in back) 32 GB on a Micro SD card)
Function
• Fault logging with real time
Saves the current stamp for better analysis
parameter settings • Multiple parameter storage
after a period of user • Automatic parameter back-up
inactivity. After an
incident, settings can
Easy to use
be retrieved from the
keypad in a couple of Optional LCD • LCD keypad with Bluetooth®
seconds. KEYPAD WITH option
BLUETOOTH® • Display contrast control
Wireless commu- • Real-time clock with time stamp
nication capability • Tactile feel buttons
between the mobile • Remote mounting of keypad
device and drive using standard RJ45 extension
cable
Advanced
Keypad Navigation
Faster scrolling and function
unction
keys offer faster navigation
gation and
short-cuts reducing program-
ming time

Start-up Wizard
Reduce basic set-up time to minutes using the start-up wizard without any drive parameter knowledge
Powerful
configuration tools
DriveWizard® is an offline/online parameter and drive configuration tool. The
easy and intuitive tool is used for set-up, maintenance and troubleshooting
offering parameter editing, storing and file comparison as well as online
trending using the highly functional oscilloscope feature.

Easy Commissioning without Power


GA700 can be programmed without any power sup-
ply connected. Simply plug into a USB port of your
PC, start programming and enjoy the ease of com-
missioning.
SUSTAINABLE FLEXIBLE

Customizable EASY

The GA700 further enhances the programming experience with


DriveWorksEZ®. DriveWorksEZ® offers an icon-based, drag-n-drop
graphical environment to add programmable functions that can tailor
the drive to meet various machine and application requirements without
the cost of external controllers, such as PLCs or additional controller
hardware options.

Application Toolbox
benefits/features:
Drive Management
with DriveWizard®
• Parameter management
• Online manual
• Report generation and export data
• 6 channel scope function
• Real-time monitoring
• Access through USB, EtherNet/IP,
Modbus TCP/IP, or PROFINET
• Automatic parameter conversion
from previous series drives

Customizable
with DriveWorksEZ®
• Icon-based graphics
• Drag-n-drop graphical interface
• Select from 400+ function blocks
• Access to I/Os, network interfaces,
drive parameters and monitors
• Logic/math functions
• Timers/counters
• Subroutine creation
• Up to 200 connections

Easy Programming
DriveWorksEZ® is the intuitive graphi-
cal programming environment for the
GA700. You create the customized func-
tion for your application in shortest time
by dragging and droping function blocks.
The online diagnosis tool supports test-
ing.

DriveWizard® and DriveWorksEZ® are registered trademarks of Yaskawa


Convenient set-up and
monitoring
Using DriveWizard Mobile the GA700 can be set up, controlled and monitored
from your smartphone or tablet easily and intuitively. Connected with the
YASKAWA Drive Cloud, DriveWizard Mobile provides quick access to latest
product manuals and your drive data, anywhere and anytime.

DriveWizard Mobile app


DriveWizard Mobile turns your smartphone or tablet into a control center
for your GA700 drives. It allows parameter setup and drive control but
also backing up your drive data locally on your smart device or in the
YASKAWA cloud. With DriveWizard Mobile all information for parameter
setup and troubleshooting of your GA700 drives are in your pocket when
you need them.
Scanning the drive QR code can provide easy access to drive information
and status with the DriveWizard Mobile application software.
SUSTAINABLE FLEXIBLE

EASY

Convenient setup and


monitoring:
DriveWizard® Mobile app
• Quick and easy drive management
apps for smart devices
• Easy USB OTG cable or Bluetooth®
connection
• Drive registration via cloud by scan-
ning QR code
• Paperless and easy access to latest
online description of parameters
and faults
• Single-click parameter and active
troubleshooting tips
• Archive and retrieve parameter set-
tings with comments on your smart
device
• Worry-free data recovery: Param-
eter back-up/retrieval anytime via
cloud service for registered drives

Yaskawa Drive Cloud Service


• Online manual
• Complimentary storage for
parameter backup and organized
record-keeping comments
• Convenient drive data storage
accessible anywhere
Flexible
and reliable
No matter if put in a control cabinet or at a wall, in clean or harsh
environment, the flexible package design of the GA700 allows a reliable
operation under various environmental conditions.

CONVENTIONAL
DRIVE

Minimum Footprint Coated Board Protection


The small foot print of the GA700 provides best usage Coated PCBs as standard protect the electronics from dust
of available panel space. Optimized heat management or humidity and ensure reliable operation even in a harsh
results in an up to 50% smaller foot print compared to environment (IEC 60723-3-3, 3C2, 3S2).
previous drives.
SUSTAINABLE FLEXIBLE

EASY

CONVENTIONAL CONVENTIONAL CONVENTIONAL CONVENTIONAL

DRIVE DRIVE DRIVE DRIVE

Enhanced Product
REDUCED benefits/features:
CABINET
SIZE
Installation ease –
panel/enclosure
• IP20 standard
• NEMA Type 1 kit optional
• NEMA Type 12/IP55 protected heatsink
• Coated boards
Side-By-Side Mounting • Side-by-side mounting
• Built-in braking chopper
The GA700 can be mounted side-by-side with bottom entry (up to 75 kW (HD))
wiring to reduce cabinet size.
Reduce harmonics/
emissions
• Built-in EMC filter, possible to disable
• Built-in DC reactor
(22kW (HD) and above

Inside of Outside of
enclosure enclosure

Easy External Back Heatsink mounting


The GA700 with a integrated flange design
offers easy installation when mounting the
heatsink outside the cabinet to reduce cabi-
net size and cooling equipment. In addition,
the factory optional Type 12/IP55 heatsink
design can provide greater protection from
dust particles while reducing cooling require-
ments resulting in smaller cabinets.

Horizontal Mounting
The GA700 can be horizontally mounted
up to 75 kW (HD)

Mounting for External Heatsink


SUSTAINABLE FLEXIBLE

Integrated EASY

functional safety
With the a built in dual channel STO (safe torque off) circuit and EDM signal
(electronic device monitor) the GA700 provides the right tools for an easy
integration of emergency stop functions into machines, even when higher
levels of safety are required.

Functional Safety benefits/


features:
Risk reduction made easy
• STO with SIL3/PLe according to IEC
61800-5-2/IEC 61508/ISO 13849
• EDM monitor
• Lower number of parts reduces instal-
lation effort while increasing reliability
• TÜV Süd certified

CONVENTIONAL
DRIVE

SE D SA
EA F
E
R
C
T
IN

Embedded Functional Safety


The built-in STO replaces mechanical
emergency relays reducing parts. The
electronic sequencing improves reliability
and cost compared to mechanical com-
ponents.
Specifications

Operating Environment
Ambient temperature -10 to +50 °C; up to +60 °C with derating at 2% per degree rise in temperature
Storage temperature -40 to +70 °C
Humidity 95 % RH or less (non-condensing)
Altitude
Protection design IP20 standard, NEMA Type 1-Kit (optional), IP55/NEMA Type 12 external heatsink (factory option)
Mounting Horizontal (0.75 kW to 75 kW (HD))
Environmental conditions IEC 60721-3-3, Class 3CS (chemical gases), Class 3S2 (solid particles)
Conformity / Standards
Standards CE, UL, cUL, EAC, RoHS
Safe Torque Off (STO) according to IEC 61800-5-2, tested according IEC/EN61508 (SIL3) and
Functional safety
ISO/EN13849-1 (Pl e, Cat. 3); TÜV Süd certified
Power Ratings
Overload capacity

Rated voltage

Capacity range (ND)

Output frequency
Carrier frequency 400V Class: 2-15 kHz up to 55 kW (ND); 2-10 kHz from 75 kW to 220 kW (ND);
2 kHz from 250 kW to 355 kW (ND)
DC Choke built-in above 22 kW (HD)
Braking chopper built-in upto 75 kW (HD)
Control / Programming
8 digital (sink/source), 3 analog (current/voltage), 1 pulse (HTL, max. 32 kHz),
Control inputs
24 Vdc power supply for control cards
4 relay, 2 analog (current/voltage), 1 pulse (HTL, max 32 kHz), 24 Vdc for external sensors
Control outputs
available (max. 150 mA)
For connection of I/O functions without physical wiring
Virtual input/output
Multiple assignment of I/O functions for easier wiring
Programming interface Mini-USB on the front cover; digital operator with Bluetooth ®
Operator LCD with copy function for several parameter sets, real time clock, data logging
Specification overview

Motor Control
Motor types Induction Motor (IM), Permanent Magnet Motor (IPM/SPM), Synchronous Reluctance Motor (SynRM)
Control methods V/f and Vector control with/without encoder, EZVector
Speed control With and without speed encoder
Zero speed With and without speed encoder
Motor parameter tuning Automatic, rotating/static
Further Functions
Integrated PID controller with sleep function
Automatic load distribution for multiple axes (droop control)
Automatic main power loss ride through
Speed Search function for smooth start of coasting motors
Braking with over-magnetization for fast stop without braking resistors
Energy-saving function
Automatic restart after failure
Overvoltage suppression
Auto stand by mode selection for energy saving
Protection / Monitoring
Stall prevention, overload prevention, overtemperature prevention- and further protective
Protective functions
functions for the motor, the application and the inverter drive
Monitoring of main components (fans, IGBTs, capacitors, charging circuit) with alarm when
Self-monitoring
reaching a certain lifetime
Options Model code
CANopen SI-S3
CC-Link SI-C3
DeviceNet SI-N3
E t h erC AT SI-ES3
Ether net/IP SI-EN3
Communication M ECH ATR O LI N K -II SI-T3
M ECH ATR O LI N K -III SI-ET3
Modbus/TCP SI-EM3
PROFIBUS-DP SI-P3
PROFINET SI-EP3
Lonworks SI-W3
I n c re m e n t a l E n c o d e r ( L i n e D r i v e r ) PG-X3
Complimentary Encoder (HTL, Open-Collector) PG-B3
Motor feedback
Resolver Interface for TS2640N321E64 PG-RT3
Absolute Encoder: Endat 2.1/01,2.2/01, Endat 2.2/22 (Heidenhain) PG-F3
(0) 4 to AI-A3
Input/Output
Digital Input: 16 Digital inputs, +24 V, at 8 mA each, sink or source,
DI-A3
multi-function or frequency reference (16-bit binary or BCD)
DO-A3
Connection diagram

DC reactor
(option)
U X Braking resistor
Main (option)
Three-phase Switch Fuse 2 1 U/T1
R/L1 R/L1 - B1 B2 U/T1
power supply: V/T2
S/L2 S/L2 V/T2 M
200 to 240 VAC or W/T3
T/L3 T/L3 W/T3
380 to 480 VAC,
50/60 Hz
Drive

Ground
Forward Run / Stop S1 Option Card
Connector
Reverse Run / Stop S2 CN5-C

CN5-B

CN5-A
External fault S3
Fault reset S4
Multi-function Multi-speed step 1 S5
digital inputs
Multi-speed step 2 S6
Jog speed S7
External Baseblock S8
SN
SC
24 VDC Output SP
+24 VDC (150 mA)
MA Fault relay output
E (G)
MB 250 VAC, max. 1 A
Shield ground terminal
MC 30 VDC, max 1 A
Pulse Train RP Pulse Train Input (max 32 kHz)
Input V Power supply +10.5 VDC, max. 20 mA
M1
V Power supply, -10.5 VDC, max. 20 mA During Run
M2
Frequency
Reference A1
Multi-function 2 k: Multi-function
analog/pulse Relay Output
train inputs Frequency -10 to +10 VDC (20 k:)/ M3
Reference 0 to +10 VDC (20 k:) M4 Zero Speed
A2 250 VAC, max. 1 A
Bias 30 VDC, max 1 A
0 to 20 mA (250 :)/
4 to 20 mA (250 :)
Aux. Freq. Ref. M5
(PTC) A3 Speed Agree
M6

AC 0 V

24 VDC Control MP Multi-function pulse train output


Power Input AC [Output frequency]
(optional) PS External Power Input VDC 0 to 32 kHz (2.2 k:)
0V
D+
MEMOBUS/Modbus
comm. RS-485 D- FM Output
max. 115.2 kBps AC  Multi-function
FM Frequency Analog Output
-10 to +10 VDC,
AM Output 0 to +10 VDC,
H1  or 4 to 20 mA
AC AM Current
H2
Safety Inputs 0V
(STO SIL3) E (G)

HC
SN
control circuit terminal
main circuit terminal
Technical data

Model designation
GA70 D 4 004 A B A
Environmental Spec
Product Series A: Standard
GA700 Series Enclosure
Region Code B: IP20
D: India EMC filter option
A: Japan A: No built-in filter
Voltage Class B: C3 built-in
C: C2 built-in
Rated output current
See Ratings Table

Data
200 V Class

Catalog Max Applicable Rated Output


Dimensions [mm] Weight
Code Motor Power Current
[kg]
GA70D HD / ND [kW] HD / ND [A] H W D
2004 0.55 / 0.75 3.2 / 3.5
2006 0.75 / 1.1 5/6
2008 1.1 / 1.5 6.9 / 8 176 3.5
2010 1.5 / 2.2 8 / 9.6
2012 2.2 / 3 11 / 12.2 260 140
2018 3 / 3.7 14 / 17.5
3.9
2021 3.7 / 5.5 17.5 / 21
211
2030 5.5 / 7.5 25 / 30
4.2
2042 7.5 / 11 33 / 42
2056 11 / 15 47 / 56 300 180 202 6.0
2070 15 / 18.5 60 / 70 8.5
350 220 227
2082 18.5 / 22 75 / 82 9.0
2110 22 / 30 88 / 110 400 240 20
280
2138 30 / 37 115 / 138 450 255 35
2169 37 / 45 145 / 169
543 264 335 40
2211 45 / 55 180 / 211
2257 55 / 75 215 / 257
700 312 420 80
2313 75 / 90 283 / 313
2360 90 / 110 346 / 360
800 440 472 120
2415 110 / - 415 / -
Data
400 V Class

4 6 0 VA C >400
460V V
Class
AC Dimensions [ mm] Dimensions [ mm]
Catalog
plica- Rated Output Max Applica- Rated Output Max Applica- Rated Output Weight Weight
Code
or Current ble Motor Current ble H
Motor W Current D [kg] H W D [kg]
GA70D
D [kW] HD / ND [A] HD / ND [kW] HD / ND [A] HD / ND [kW] HD / ND [A]
0.75 1.8 4002
/ 2.1 0.55 / 0.75 1.6
1.8 / 2.1 0.55 / 0.75 1.6 / 2.1
1.5 3.4 4004
/ 4.1 0.75 / 1.5 3.4
2.1/ /4.1
3 0.75 / 1.5 2.1176
/3 3.5 176 3.5
2.2 4.8 4005
/ 5.4 1.5 / 2.2 4.8 / 4.8
3.4 5.4 1.5 / 2.2 3.4 / 4.8
3.0 5,5 4007
/ 7.1 2.2 / 3.0 5.5 / 6.9
4.8 7.1 2.2 / 3.0 4.8 / 6.9
260 140 260 140
4.0 7.2 4009
/ 8.9 3.0 / 4.0 6.9
7.2 / 7.6
8.9 3.0 / 4.0 6.9 / 7.6 3.9 3.9
5.5 9.2 /4012
11.9 3.7 / 5.5 7.6/ /11.9
9.2 11 3.7 / 5.5 7.6 211
/ 11 211
7.5 14.8 4018
/ 17.5 5.5 / 7.5 14.8 17.5
11 / 14 5.5 / 7.5 11 / 14
4.2 4.2
11 18 /4023
23.4 7.5 / 11 18
14/ /23.4
21 7.5 / 11 14 / 21
15 24 4031
/ 31 11 / 15 21
24 / 27
31 11 / 15 21 / 27
300 180 202 6.0
300 180 202 6.0
18.5 31 4038
/ 38 15 / 18.5 27
31 / 34
38 15 / 18.5 27 / 34
/ 22 39 4044
/ 44 18.5 / 22 39 / 40
34 44 18.5 / 22 34 /227
40 7.5 227 7.5
350 220 350 220
30 45 /4060
59.6 22 / 30 4450/ /5592.6 22 / 30 40 /24
562 13 246 13
37 60 /4075
74.9 30 / 37 60
52/ /74.9
65 400
30 / 37 240 52 / 65 16
400 240 16
45 75 /4089
89.2 37 / 45 75
65/ /89.2
77 37 / 45 65 /280
77 280
450 255 35
450 255 35
55 91 /4103
103 45 / 55 91
77 // 103
96 45 / 55 77 / 96
75 112 4140
/ 140 55 / 75 96 //124
112 140 55 / 75 96 / 124
543 264 335 543
40 264 335 40
90 150 4168
/ 168 75 / 90 124
150 / 156
168 75 / 90 124 / 156
110 180 4208
/ 208 90 / 110 156
180 / 180
208 90 / 110 156 / 180
132 216 4250
/ 250 110 / 150
132 180
216 / 240
250 700
110 / 150 312 180 /420
240 80
700 312 420 80
160 260 4296
/ 296 150
132 / 185
160 240
260 / 302
296 150 / 185 240 / 302
200 304 4371
/ 371 185
160 / 220
200 302
304 / 361
371 185 / 220 302 / 361
800 440 472 800
120 440 472 120
220 371 4389
/ 389 220
200 / 260
220 361
371 / 414
389 220 / 260 361 / 414
250 414 4453
/ 453 260
220 / 300
250 414 / 477
453 260 / 300 414 / 477
315 453 4568
/ 568 300
250 / 335
315 477
453 / 515
568 1140
300 / 335 510 477 /480
515 1140
175 510 480 175
355 605 4675
/ 675 370
315 / 450
355 590
605 / 720
675 370 / 450 590 / 720
YASKAWA India Pvt. Ltd.,
17/A, 2nd Main, Electronic city, Phase 1
Hosur Road, Bangalore 560 100.

E-mail: info@yaskawa.in
Phone: 080 4244 1900
Web: www.yaskawaindia.in
Data sheet 3RH2122-1AP00

Contactor relay, 2 NO + 2 NC, 230 V AC, 50 / 60 Hz, Size S00, screw


terminal

product brand name SIRIUS


product designation Auxiliary contactor
product type designation 3RH2
General technical data
size of contactor S00
product extension auxiliary switch Yes
insulation voltage with degree of pollution 3 at AC rated 690 V
value
degree of pollution 3
surge voltage resistance rated value 6 kV
shock resistance at rectangular impulse
● at AC 7,3g / 5 ms, 4,7g / 10 ms
shock resistance with sine pulse
● at AC 11,4g / 5 ms, 7,3g / 10 ms
mechanical service life (switching cycles)
● of contactor typical 30 000 000
● of the contactor with added electronically optimized 5 000 000
auxiliary switch block typical
● of the contactor with added auxiliary switch block 10 000 000
typical
reference code acc. to IEC 81346-2 K
Substance Prohibitance (Date) 01.10.2009 00:00:00
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation -25 ... +60 °C
● during storage -55 ... +80 °C
Main circuit
no-load switching frequency
● at AC 10 000 1/h
● at DC 10 000 1/h
Control circuit/ Control
type of voltage of the control supply voltage AC
control supply voltage at AC
● at 50 Hz rated value 230 V
● at 60 Hz rated value 230 V
control supply voltage frequency
● 1 rated value 50 Hz
● 2 rated value 60 Hz
operating range factor control supply voltage rated

3RH21221AP00 Subject to change without notice


9.25.2021
Page 1/7 © Copyright Siemens
value of magnet coil at AC
● at 50 Hz 0.8 ... 1.1
● at 60 Hz 0.85 ... 1.1
apparent pick-up power of magnet coil at AC 37 V·A
inductive power factor with closing power of the coil 0.8
apparent holding power of magnet coil at AC 5.7 V·A
inductive power factor with the holding power of the 0.25
coil
closing delay
● at AC 8 ... 33 ms
opening delay
● at AC 4 ... 15 ms
arcing time 10 ... 15 ms
Auxiliary circuit
number of NC contacts for auxiliary contacts 2
● instantaneous contact 2
number of NO contacts for auxiliary contacts 2
● instantaneous contact 2
identification number and letter for switching 22 E
elements
operational current at AC-12 maximum 10 A
operational current at AC-15
● at 230 V rated value 10 A
● at 400 V rated value 3A
● at 500 V rated value 2A
● at 690 V rated value 1A
operational current at 1 current path at DC-12
● at 24 V rated value 10 A
● at 110 V rated value 3A
● at 220 V rated value 1A
● at 440 V rated value 0.3 A
● at 600 V rated value 0.15 A
operational current with 2 current paths in series at
DC-12
● at 24 V rated value 10 A
● at 60 V rated value 10 A
● at 110 V rated value 4A
● at 220 V rated value 2A
● at 440 V rated value 1.3 A
● at 600 V rated value 0.65 A
operational current with 3 current paths in series at
DC-12
● at 24 V rated value 10 A
● at 60 V rated value 10 A
● at 110 V rated value 10 A
● at 220 V rated value 3.6 A
● at 440 V rated value 2.5 A
● at 600 V rated value 1.8 A
operating frequency at DC-12 maximum 1 000 1/h
operational current at 1 current path at DC-13
● at 24 V rated value 10 A
● at 110 V rated value 1A
● at 220 V rated value 0.3 A
● at 440 V rated value 0.14 A
● at 600 V rated value 0.1 A
operational current with 2 current paths in series at
DC-13
● at 24 V rated value 10 A
● at 60 V rated value 3.5 A
● at 110 V rated value 1.3 A
● at 220 V rated value 0.9 A

3RH21221AP00 Subject to change without notice


9.25.2021
Page 2/7 © Copyright Siemens
● at 440 V rated value 0.2 A
● at 600 V rated value 0.1 A
operational current with 3 current paths in series at
DC-13
● at 24 V rated value 10 A
● at 60 V rated value 4.7 A
● at 110 V rated value 3A
● at 220 V rated value 1.2 A
● at 440 V rated value 0.5 A
● at 600 V rated value 0.26 A
operating frequency at DC-13 maximum 1 000 1/h
design of the miniature circuit breaker for short-circuit C characteristic: 6 A; 0.4 kA
protection of the auxiliary circuit up to 230 V
contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
contact rating of auxiliary contacts according to UL A600 / Q600
Short-circuit protection
design of the fuse link for short-circuit protection of the fuse gL/gG: 10 A
auxiliary switch required
Installation/ mounting/ dimensions
mounting position +/-180° rotation possible on vertical mounting surface; can be tilted
forward and backward by +/- 22.5° on vertical mounting surface
fastening method screw and snap-on mounting onto 35 mm standard mounting rail
height 57.5 mm
width 45 mm
depth 73 mm
required spacing
● with side-by-side mounting
— forwards 10 mm
— upwards 10 mm
— downwards 10 mm
— at the side 0 mm
● for grounded parts
— forwards 10 mm
— upwards 10 mm
— at the side 6 mm
— downwards 10 mm
● for live parts
— forwards 10 mm
— upwards 10 mm
— downwards 10 mm
— at the side 6 mm
Connections/ Terminals
type of electrical connection for auxiliary and control circuit screw-type terminals
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
Safety related data
B10 value with high demand rate acc. to SN 31920 1 000 000; With 0.3 x Ie
proportion of dangerous failures
● with low demand rate acc. to SN 31920 40 %
● with high demand rate acc. to SN 31920 73 %
failure rate [FIT] with low demand rate acc. to SN 31920 100 FIT
T1 value for proof test interval or service life acc. to 20 y
IEC 61508
protection class IP on the front acc. to IEC 60529 IP20
touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front
Certificates/ approvals

3RH21221AP00 Subject to change without notice


9.25.2021
Page 3/7 © Copyright Siemens
General Product Approval EMC

KC

Functional
Safety/Safety of Declaration of Conformity Test Certificates Marine / Shipping
Machinery

Type Examination UK Declaration of Type Test Certific- Special Test Certific-


Certificate Conformity ates/Test Report ate

Marine / Shipping

other

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RH2122-1AP00
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RH2122-1AP00
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RH2122-1AP00
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RH2122-1AP00&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RH2122-1AP00/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RH2122-1AP00&objecttype=14&gridview=view1

3RH21221AP00 Subject to change without notice


9.25.2021
Page 4/7 © Copyright Siemens
3RH21221AP00 Subject to change without notice
9.25.2021
Page 5/7 © Copyright Siemens
3RH21221AP00 Subject to change without notice
9.25.2021
Page 6/7 © Copyright Siemens
last modified: 12/15/2020

3RH21221AP00 Subject to change without notice


9.25.2021
Page 7/7 © Copyright Siemens
Data sheet 5SL4106-7RC

Miniature circuit breaker 240/415 V 10kA, 1-pole, C, 6A

Model
product brand name SENTRON
product designation Miniature circuit breaker
General technical data
number of poles 1
design of pole 1P
tripping characteristic class C
mechanical service life (switching cycles) / typical 10 000
overvoltage category III
degree of pollution 2
Voltage
type of voltage / of the operating voltage AC
insulation voltage (Ui)
● with single-phase operation / at AC / rated value 250 V
● with multi-phase operation / at AC / rated value 440 V
Supply voltage
supply voltage / at AC / rated value 415 V
operating voltage
● with multi-phase operation / at AC / maximum 440 V
● at DC / rated value / maximum 72 V
Protection class
protection class IP IP20, with connected conductors
Switching capacity
switching capacity current
● acc. to EN 60898 / rated value 10 kA
energy limitation class 3
Dissipation
power loss [W] / for rated value of the current / at AC / in 0.86 W
hot operating state / per pole
Current
operational current
● at 30 °C / rated value 6A
● at AC / rated value 6A
suitability for operation Residential buildings/infrastructure
Product details
product component / neutral conductor switching No
product feature / touch protection Yes
product feature
● halogen-free Yes

5SL41067RC Subject to change without notice


9.24.2021
Page 1/4 © Copyright Siemens
● sealable Yes
● silicon-free Yes
product extension / installable / supplementary devices Yes
Connections
connectable conductor cross-section / solid
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / stranded
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / finely stranded /
with core end processing
● minimum 0.75 mm²
● maximum 25 mm²
tightening torque / with screw-type terminals
● minimum 2.5 N·m
● maximum 3 N·m
Mechanical Design
height 90 mm
width 18 mm
depth 76 mm
installation depth 70 mm
number of modular width units 1
mounting position any
net weight 125 g
Environmental conditions
ambient temperature / during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature / during storage
● minimum -40 °C
● maximum 75 °C
Certificates
reference code
● acc. to DIN EN 61346-2 F
● acc. to IEC 81346-2 F
General Product Declaration of
Test Certificates other
Approval Conformity

Miscellaneous Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=5SL4106-7RC
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/5SL4106-7RC
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=5SL4106-7RC
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

5SL41067RC Subject to change without notice


9.24.2021
Page 2/4 © Copyright Siemens
5SL41067RC Subject to change without notice
9.24.2021
Page 3/4 © Copyright Siemens
5SL41067RC Subject to change without notice
9.24.2021
Page 4/4 © Copyright Siemens
Data sheet 5SL4206-7RC

Miniature circuit breaker 415 V 10kA, 2-pole, C, 6A

Model
product brand name SENTRON
product designation Miniature circuit breaker
General technical data
number of poles 2
design of pole 2P
tripping characteristic class C
mechanical service life (switching cycles) / typical 10 000
overvoltage category III
degree of pollution 2
Voltage
type of voltage / of the operating voltage AC
insulation voltage (Ui)
● with single-phase operation / at AC / rated value 250 V
● with multi-phase operation / at AC / rated value 440 V
Supply voltage
supply voltage / at AC / rated value 415 V
operating voltage
● with multi-phase operation / at AC / maximum 440 V
● at DC / rated value / maximum 72 V
Protection class
protection class IP IP20, with connected conductors
Switching capacity
switching capacity current
● acc. to EN 60898 / rated value 10 kA
energy limitation class 3
Dissipation
power loss [W] / for rated value of the current / at AC / in 0.86 W
hot operating state / per pole
Current
operational current
● at 30 °C / rated value 6A
● at AC / rated value 6A
suitability for operation Residential buildings/infrastructure
Product details
product component / neutral conductor switching No
product feature / touch protection Yes
product feature
● halogen-free Yes

5SL42067RC Subject to change without notice


9.25.2021
Page 1/4 © Copyright Siemens
● sealable Yes
● silicon-free Yes
product extension / installable / supplementary devices Yes
Connections
connectable conductor cross-section / solid
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / stranded
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / finely stranded /
with core end processing
● minimum 0.75 mm²
● maximum 25 mm²
tightening torque / with screw-type terminals
● minimum 2.5 N·m
● maximum 3 N·m
Mechanical Design
height 90 mm
width 18 mm
depth 76 mm
installation depth 70 mm
number of modular width units 1
mounting position any
net weight 252 g
Environmental conditions
ambient temperature / during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature / during storage
● minimum -40 °C
● maximum 75 °C
Certificates
reference code
● acc. to DIN EN 61346-2 F
● acc. to IEC 81346-2 F
General Product Declaration of
Test Certificates other
Approval Conformity

Miscellaneous Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=5SL4206-7RC
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/5SL4206-7RC
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=5SL4206-7RC
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

5SL42067RC Subject to change without notice


9.25.2021
Page 2/4 © Copyright Siemens
5SL42067RC Subject to change without notice
9.25.2021
Page 3/4 © Copyright Siemens
5SL42067RC Subject to change without notice
9.25.2021
Page 4/4 © Copyright Siemens
Data sheet 5SL4420-7RC

Miniature circuit breaker 415 V 10kA, 4-pole, C, 20 A

Model
product brand name SENTRON
product designation Miniature circuit breaker
General technical data
number of poles 4
design of pole 4P
tripping characteristic class C
mechanical service life (switching cycles) / typical 10 000
overvoltage category III
degree of pollution 2
Voltage
type of voltage / of the operating voltage AC
insulation voltage (Ui)
● with single-phase operation / at AC / rated value 250 V
● with multi-phase operation / at AC / rated value 440 V
Supply voltage
supply voltage / at AC / rated value 415 V
operating voltage
● with multi-phase operation / at AC / maximum 440 V
● at DC / rated value / maximum 72 V
Protection class
protection class IP IP20, with connected conductors
Switching capacity
switching capacity current
● acc. to EN 60898 / rated value 10 kA
energy limitation class 3
Dissipation
power loss [W] / for rated value of the current / at AC / in 2.17 W
hot operating state / per pole
Current
operational current
● at 30 °C / rated value 20 A
● at AC / rated value 20 A
suitability for operation Residential buildings/infrastructure
Product details
product component / neutral conductor switching No
product feature / touch protection Yes
product feature
● halogen-free Yes

5SL44207RC Subject to change without notice


9.25.2021
Page 1/4 © Copyright Siemens
● sealable Yes
● silicon-free Yes
product extension / installable / supplementary devices Yes
Connections
connectable conductor cross-section / solid
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / stranded
● minimum 0.75 mm²
● maximum 25 mm²
connectable conductor cross-section / finely stranded /
with core end processing
● minimum 0.75 mm²
● maximum 25 mm²
tightening torque / with screw-type terminals
● minimum 2.5 N·m
● maximum 3 N·m
Mechanical Design
height 90 mm
width 18 mm
depth 76 mm
installation depth 70 mm
number of modular width units 1
mounting position any
net weight 522 g
Environmental conditions
ambient temperature / during operation
● minimum -25 °C
● maximum 55 °C
ambient temperature / during storage
● minimum -40 °C
● maximum 75 °C
Certificates
reference code
● acc. to DIN EN 61346-2 F
● acc. to IEC 81346-2 F
General Product Declaration of
Test Certificates other
Approval Conformity

Miscellaneous Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/lowvoltage/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=5SL4420-7RC
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/5SL4420-7RC
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=5SL4420-7RC
CAx-Online-Generator
http://www.siemens.com/cax
Tender specifications
http://www.siemens.com/specifications

5SL44207RC Subject to change without notice


9.25.2021
Page 2/4 © Copyright Siemens
5SL44207RC Subject to change without notice
9.25.2021
Page 3/4 © Copyright Siemens
5SL44207RC Subject to change without notice
9.25.2021
Page 4/4 © Copyright Siemens
EF
High flow filter fan

CONNECT AND PROTECT

This vertical filter fan, EF, with a IP 54 protection


degree, is easy to install thanks to its click-in feature.
Unnecessary downtime is avoided, since water and dust
are prevented from entering the enclosure through the
filter, and the reliable fan motor will ensure constant
ventilation.

Description: Filter fan for forced ventilation. nVent HOFFMAN


filter fans save time on installation as they are installed with a
click-in system without screws. The hinged front cover can be
easily opened for quick and easy filter replacement. The airflow
direction and the connection position can easily be changed.
Material: Front cover manufactured from injection-
moulded thermoplastic, self-extinguishing, UL94V0.
Temperature range: -40 °C to +55 °C.
Protection: IP 54 | TYPE 12.
Finish: RAL 7035.
Pack quantity: One fan with filter.

IP 54 | TYPE 12

nVent HOFFMAN | 1 / 4
EF
High flow filter fan

CONNECT AND PROTECT

nVent HOFFMAN | 2 / 4
EF
High flow filter fan

CONNECT AND PROTECT

230 V AC, 50/60 Hz


Service
EF+EFA
Filter mat life L10 Bearing Noise Cut-out Weight Current Power
Air flow Filtration Fuse (A) Item no.
(EN779) (40ºC) type (dB) (mm) (kg) (A) (W)
(m³/h)
(h)
310 mm
19/24 12/14 G4 >90 52.500 Sleeve 33 92 × 92 0.55 0.07/0.06 12/11 6 EF100R5
cable
125 × Terminal
61/67 44/50 G4 >90 37.500 Sleeve 44 0.80 0.12/0.18 19/18 6 EF200R5
125 strip
177 × Terminal
98/108 73/80 G4 >90 37.500 Sleeve 40 1.05 0.12/0.18 19/18 6 EF220R5
177 strip
223 × Spring
125/138 93/102 G4 >90 40.000 Ball 40 1.45 0.12/0.10 18/17 6 EF250R5
223 type
223 × Spring
223/247 201/223 G4 >90 40.000 Ball 42 1.90 0.32/0.26 45/39 6 EF300R5
223 type
292 × Spring
480/480 370/370 G3 80-90 40.000 Ball 54 3.85 0.30/0.36 80/100 6 EF500R5
292 type
292 × Spring
640/653 445/445 G3 80-90 40.000 Ball 63 4.05 0.51/0.66 120/160 6 EF600R5
292 type
292 × Spring
845/875 560/625 G3 80-90 40.000 Ball 66 4.50 0.59/0.88 140/197 6 EF700R5
292 type

115 V AC, 50/60Hz


Service
EF+EFA
Filter mat life L10 Bearing Noise Cut-out Weight Current Power
Air flow Filtration Fuse (A) Item no.
(EN779) (40ºC) type (dB) (mm) (kg) (A) (W)
(m³/h)
(h)
310 mm EF100-
19/24 12/14 G4 >90 55.000 Sleeve 33 92 × 92 0.55 0.15/0.15 12/11 6
cable 115R5
125 × Terminal EF200-
61/67 44/50 G4 >90 40.000 Sleeve 44 0.80 0.24/0.23 20/20 6
125 strip 115R5
177 × Terminal EF220-
98/108 73/80 G4 >90 40.000 Sleeve 40 1.05 0.24/0.23 20/20 6
177 strip 115R5
223 × Spring EF250-
125/138 93/102 G4 >90 42.500 Ball 43 1.45 0.25/0.25 18/17 6
223 type 115R5
223 × Spring EF300-
223/247 201/223 G4 >90 40.000 Ball 46 1.90 0.50/0.50 40/40 6
223 type 115R5
291 × Spring EF500-
480/480 370 G3 80-90 40.000 Ball 52 3.85 0.66/0.80 75/90 6
291 type 115R5
291 × Spring EF600-
640/653 445 G3 80-90 40.000 Ball 64 4.10 0.96/1.40 110/160 6
291 type 115R5
291 × Spring EF700-
845/875 625 G3 80-90 40.000 Ball 69 4.50 1.23/1.71 140/195 6
291 type 115R5

24 V DC
Service
EF+EFA
Filter mat life L10 Bearing Noise Cut-out Weight Current Power
Air flow Filtration Fuse (A) Item no.
(EN779) (40ºC) type (dB) (mm) (kg) (A) (W)
(m³/h)
(h)
310 mm EF100-
19/24 12/14 G4 >90 70.000 Ball 33 92 × 92 0.25 0.10 2.40 6
cable 24R5
125 × 310 mm EF200-
61/67 44/50 G4 >90 62.500 Ball 44 0.45 0.21 5.00 6
125 cable 24R5
177 × 310 mm EF220-
98/108 73/80 G4 >90 62.500 Ball 40 0.70 0.21 5.00 6
177 cable 24R5
223 × Spring EF250-
125/138 93/102 G4 >90 70.000 Ball 40 1.40 0.20 4.70 6
223 type 24R5
223 × Spring EF300-
223/247 201/223 G4 >90 80.000 Ball 42 1.45 0.50 12.00 6
223 type 24R5

nVent HOFFMAN | 3 / 4
EF
High flow filter fan

CONNECT AND PROTECT

nVent HOFFMAN | 4 / 4
Manufacturer assumes no responsibility for a hazard or
damage caused by incorrect or non-application of any of the
instructions attached herein. Under no circumstance shall 1.Features
Larsen & Toubro be liable for any consequential or resulting
injury or for loss, damage or expense directly or indirectly from · Accuracy class 1 as per IEC 62053-21, class 0.5, 0.5S as per IEC 62053-22
the use of this product. Sufficient care is taken to provide all · True RMS measurement
INSTRUCTION MANUAL information regarding the product but Larsen & Toubro does
not claim any responsibility for the damage caused by using the · Password protection provision
product directly or indirectly. Use according to the operating · Site selectable for 3 Phase 4 Wire, 3 Phase 3 Wire, 1 Phase
Digital Panel Meter instructions, professional practices, wiring rules, codes, safety
regulations applicable to the given installation. · Site programmable CT/PT ratio
Basic Multifunction Meter · Auto-scaling of kilo, mega & giga values
During normal operation of this instrument ,hazardous · Positive accumulation of active energy
4400 LED series voltages are present at the rear terminals, which can cause · Autoscrolling & freeze mode provision is available
injury or death. Installation ,disconnection or removal of the
meter should be carried out only by qualified, trained · User selectable energy measurement : Wh/VAh
personnel, after de-energizing connected circuits. Improper
installation , including improper grounding will void warranty.
Product warranty void if seal is broken.

2. LED Indication 3. Display of Parameters 4. Technical Specification


WL 4400
Display Meaning Total Watts 3 Ph 4 W, 3 Ph 3 W, 1 Ph
LL Voltage Line to Line PF Power Factor Type of Type True RMS, 64 samples
measurement per cycle 1 sec update
Lag (ON) Voltage Line to Neutral Active Energy Received time
M Mega Both on
41 5.0 P.P -

Kilo
{Giga Voltage RY Phase Load Hour Class 1 as per
K
IEC 62053-21
Reverse
Communication Voltage YB Phase Power Factor R Phase/Y Phase/B Phase Measurement
REV DO
Class 0.5 as per
ON
Voltage BR Phase VA - R Phase/Y Phase/B Phase accuracy IEC 62053-22
Digital Output PRG
Pulse
MULTIFUNCTION METER A Average Current Voltage R / Y / B Phase Class 0.5S as per
IEC 62053-22
To select the value F Frequency Current R / Y / B Phase 4 digit for instantaneous
To edit the
or accept the value
Display type LED
value/Parameter & 6 digits for cumulative
in programming in programming UA Total VA Watts R / Y / B Phase & resolution
mode mode

50 - 550 VLL Impulse voltage test ±6 kV as per IEC 62052-11


Insulation
PT Primary and Secondary user programmable AC voltage test 4 kV double insulation as per IEC 62053-21
Input voltage for LT and HT applications properties
Insulation resistance 500 V DC as per IS 13779
Burden: 0.2VA max per phase Operating temperature O
-10 C to +55 C
O

Measuring -/5A and -/1A site selectable Storage temperature O


-25 C to +70 C
O
Operating
circuit Current range from 10% to 120% of In (50mA-5A), conditions Humidity 5% to 95% relative humidity non-condensing
Input current Starting current : 0.4% of full scale
Recommended wire 2.5 sq mm
CT Primary and Secondary user Shock As per standard IEC 60068-2
programmable for LT and HT applications Mechanical Vibration 10 to 55 Hz, 0.15 mm amplitude
Frequency 40 - 70 Hz conditions
Casing Plastic mould protected to IP51 from front side
Aux voltage 80 - 300V AC/DC Measurement category CAT III
Auxiliary <5VA
circuit Aux burden Safety Pollution degree 2
Freq range 40 - 70 Hz Protection IP20 at terminals, IP51 on front
Test of power consumption as per IEC 62053-21 Product weight 300 gms
Electrical
Voltage dips and interrupts as per IEC 62053-21 Weight & Bezel dimension (W x H x D) 96 x 96 x 58 mm
requirements dimensions
Short time over current protection 10A max continuous, 20 times of In for 3 sec Panel cutout 92 x 92 mm +0.8
- 0.0
Fast transients burst test ±4 kV as per IEC 61000-4-4
Outputs Meter constant: 1250/(external CT ratio x PT ratio)
Immunity to ±8 kV air discharge, ±6 kV contact
electrostatic discharge discharge as per IEC 61000-4-2 Type RS485 port Modbus RTU
Electro- Radiated, Radio-frequency, Baud rate 2400, 4800, 9600, 19200 bps (site selectable)
10 V/m as per 61000-4-3
magnetic Electromagnetic field immunity test Parity Odd, Even, None
compatibility Immunity to electromagnetic HF Communication
10 V/m as per IEC 61000-4-6 Slave id 1 to 247 (programmable)
(EMC) fields through conducted lines
Surge immunity test ±6 kV as per IEC 61000-4-5 Isolation 2 kVAC isolation for 1 minute between
Rated power frequency magnetic fields 1 A/m as per IEC 61000-4-8 communication and other circuits
Emission Class B as per CISPR 22 Certifications CE, RoHS
5. Programming Mode 5.2.2. Programming Mode PT Secondary 4150P.S 415.0 50V to 550V
5.1 Programming keys · Press DOWN to enter Programming Mode
CT Primary 5000C.P 5.000 0.5A - 99kA
· Press UP key to select the Edit Mode
To select Edit Mode and save parameter  Blink indicates Edit Mode is ON CT Secondary 5000C.S 5.000 0.5A - 6A
DOWN to decrement value or parameter · Press DOWN to decrement values or Yes/No
to select from available options Reverse Lock No If YES it blocks energy accumulation in
5.2 General Programming Guide case the CT polarity reverse.
· Press UP to accept the value of the parameter
· Press UP + Down to enter Programming Mode · Press DOWN to edit next parameters till end Method of VA Selection:
VA Selection UE C.H UA. VECH Arithmetic /Vector harmonics /Vector
· Enter Password (default value 0000) after the configuration of last parameter display
· Blink indicates Edit Mode is ON screen will prompt “SAVE”, Display reads “Y” (YES) *Digital output 1 disable Single Phase/Wh/Under PF, F, A, V/ Over W, F, A, V
· Press DOWN to decrement value · Press DOWN to change to “ ” (NO) *Threshold value 1 1000 000-999.9 M
0/9/8/7/6/5/4/3/2/1 · Press UP to save *Digital Output Delay 3.000 1-180 sec
· Press UP to move to the next digit till 4th digit
If Password is correct, meter display reads 5.3. Display Baud Rate 9600 2400, 4800, 9600 19.2k
For Clear Mode move to step 5.2.1 First four digit : Parameter value Parity Even Even/Odd/none
For Programming Mode move to step 5.2.2 41 5.0 P.P 5th & 6th digit : Parameter to edit Slave Id 1 . 0 0 0 S L 1.000 1 to 247

5.2.1.Clear Mode Programming PASSWORD 0000 0000 to 9999


Default Option/Range
· Press UP to Enter Clear Mode Display reads “ ” Parameter Energy Resolution Resolution/Counter
· Press UP to clear parameter. Display prompts “ ” Pulse Output ON time 2 5 0 . 0 p o 250 50 to 500 msec
ConFIG
· Press DOWN to change for “y” (yes) to clear values Defines the 3P 4W Energy Selection Wh Wh/VAh
· Press UP to clear power system 3P 4W 3P 3W
configuration. * Optional for select product variants
1 Phase
If password is incorrect, meter will display next 5.4. Enabling and Disabling Auto Scrolling
parameter but cannot be edited. 100V-999kV Press DOWN for 6 secs
To set 33kV Set first four digits
PT Primary (3300) as explained above press Display Shows: EnbL. Au.
415 UP/DOWN key to place decimal point
Again press DOWN for 6 sec
4150P.P at appropriate location.
Letter K/M will indicate the Kilo/Mega. Display Shows: dSbL. Au.
M & K both LED will glow for Giga

6. Memory Map

Address Parameter Data type Address Parameter Data type Address Parameter Data type Address Parameter Data type

40101 Watts Total float 40123 PF B phase float 40137 VY B phase float 40151 Current R phase float
40103 Watts R phase float 40125 VA total float 40139 VB R phase float 40153 Current Y phase float
40105 Watts Y phase float 40127 VA R phase float 40141 VL N average float 40155 Current B phase float
40107 Watts B phase float 40129 VA Y phase float 40143 V R phase float 40157 Frequency float
40117 PF Avg (inst) float 40131 VA B phase float 40145 V Y phase float 40159 Wh float
40119 PF R phase float 40133 VL L average float 40147 V B phase float 40161 VAh float
40121 PF Y phase float 40135 VR Y phase float 40149 Current Total float 40217 Load Hours Unsigned long

7. Wiring Diagram 8. Mounting Dimensions


In case of complaint please contact

WL44000501A
+2.0
90 - 0.0 Steps for Mounting
CUSTOMER INTERACTION CENTRE (CIC)
Insert meter to panel
Received (Import) Delivered (Export) Received (Import) Delivered (Export) Received (Import) Delivered (Export) 1 TOLL-Free: 1800 233 5858, 1800 200 5858
without clamps
Telephone : 022 6774 5858
2 2
Load Line Load Line Load Line 1 Insert both clamps email: cic@LNTEBG.com
3

+2.0
90 - 0.0

L&T Electrical & Automation


AMF IP AMF IP AMF IP
240V AC 240V AC 240V AC

Electrical Standard Products


L&T Business Park, Tower 'B' / 3rd Floor
54mm
3 Saki Vihar Road, Powai Mumbai 400 072
3 Phase 4 Wire System 3 Phase 3 Wire System Single Phase System 4mm
Website: www.Lntebg.com
Manufacturer assumes no responsibility for a hazard or
damage caused by incorrect or non-application of any of the
instructions attached herein. Under no circumstance shall 1.Features
Larsen & Toubro be liable for any consequential or resulting
injury or for loss, damage or expense directly or indirectly from · Accuracy class 1 as per IEC 62053-21, class 0.5 as per IEC 62053-22
the use of this product. Sufficient care is taken to provide all · True RMS measurement
INSTRUCTION MANUAL information regarding the product but Larsen & Toubro does
not claim any responsibility for the damage caused by using the · Password protection provision
product directly or indirectly. Use according to the operating · Site selectable for 3 Phase 4 Wire, 3 Phase 3 Wire, 1 Phase
Digital Panel Meter instructions, professional practices, wiring rules, codes, safety
regulations applicable to the given installation. · Site programmable CT/PT ratio
Basic Multifunction Meter · Auto-scaling of kilo, mega & giga decimal value
During normal operation of this instrument ,hazardous · Positive accumulation of active energy
4400 LCD series voltages are present at the rear terminals, which can cause · Autoscrolling & freeze mode provision is available
injury or death. Installation ,disconnection or removal of the · User selectable energy measurement : Wh/VAh
meter should be carried out only by qualified, trained
personnel, after de-energizing connected circuits. Improper
installation , including improper grounding will void warranty.
Product warranty void if seal is broken.

2. LED Indication 3. Display of Parameters 4. Technical Specification


WC 4400
Display Meaning PF Power Factor 3 Ph 4 W, 3 Ph 3 W, 1 Ph
LL Voltage Line to Line Active Energy Received Type of Type True RMS, 64 samples
measurement per cycle 1 sec update
Voltage Line to Neutral Load Hour
time
Voltage RY Phase Power Factor R Phase/Y Phase/B Phase
Class 1 as per
Voltage YB Phase VA - R Phase/Y Phase/B Phase IEC 62053-21
Voltage R / Y / B Phase Measurement Class 0.5 as per
Voltage BR Phase accuracy IEC 62053-22
Pulse
A Average Current Current R / Y / B Phase
PRG Class 0.5S as per
MULTIFUNCTION METER F Frequency Watts R / Y / B Phase IEC 62053-22
Communication To edit the To select the value UA Total VA Display type LCD 4 digit for instantaneous
value/Parameter or accept the value
ON in programming in programming Total Watts and resolution & 7 digits for cumulative
mode mode

50 - 550 VLL Impulse voltage test ±6 kV as per IEC 62052-11


Insulation
PT Primary and Secondary user programmable AC voltage test 4 kV double insulation as per IEC 62053-21
Input voltage for LT and HT applications properties
Insulation resistance 500 V DC as per IS 13779
Burden: 0.2VA max per phase Operating temperature
O
-10 C to +55 C
O

Measuring -/5A and -/1A site selectable Storage temperature


O
-25 C to +70 C
O
Operating
circuit Current range from 10% to 120% of In (50mA-6A), conditions Humidity 5% to 95% relative humidity non-condensing
Input current Starting current : 0.6% of full scale
Recommended wire 2.5 sq mm
CT Primary and Secondary user Shock As per standard IEC 60068-2
programmable for LT and HT applications Mechanical Vibration 10 to 55 Hz, 0.15 mm amplitude
Frequency 40 - 70 Hz conditions
Casing Plastic mould protected to IP51 from front side
Aux voltage 80 - 300V AC/DC Measurement category CAT III
Auxiliary <5VA
circuit Aux burden Safety Pollution degree 2
Freq range 40 - 70 Hz Protection IP20 at terminals, IP51 on front
Test of power consumption as per IEC 62053-21 Product weight 300 gms
Electrical
Voltage dips and interrupts as per IEC 62053-21 Weight & Bezel dimension (W x H x D) 96 x 96 x 58 mm
requirements dimensions
Short time over current protection 10A max continuous, 20 times of In for 3 sec Panel cutout 92 x 92 mm +0.8
- 0.0
Fast transients burst test ±4 kV as per IEC 61000-4-4
Outputs Meter constant: 2500/(external CT ratio x PT ratio)
Immunity to ±8 kV air discharge, ±6 kV contact
electrostatic discharge discharge as per IEC 61000-4-2 Type RS485 port Modbus RTU
Electro- Radiated, Radio-frequency, Baud rate 2400, 4800, 9600, 19200 bps (site selectable)
10 V/m as per 61000-4-3
magnetic Electromagnetic field immunity test Parity Odd, Even, None
compatibility Immunity to electromagnetic HF Communication
10 V/m as per IEC 61000-4-6 Slave id 1 to 247 (programmable)
(EMC) fields through conducted lines
Surge immunity test ±6 kV as per IEC 61000-4-5 Isolation 2 kVAC isolation for 1 minute between
Rated power frequency magnetic fields 1 A/m as per IEC 61000-4-8 communication and other circuits
Emission Class B as per CISPR 22 Certifications CE, RoHS
5. Programming Mode 5.2.2. Programming Mode PT Secondary P.SY415.0 415.0 50V to 550V
5.1 Programming keys · Press DOWN to enter Programming Mode CT Primary 5.000 0.5A - 99kA
· Press UP key to select the Edit Mode
To select Edit Mode and save parameter  Blink indicates Edit Mode is ON CT Secondary C.SY5.000 5.000 0.5A - 6A
DOWN to decrement value or parameter · Press DOWN to decrement values or Yes/No
to select from available options Reverse Lock No If YES it blocks energy accumulation in
case the CT polarity reverse.
5.2 General Programming Guide · Press UP to accept the value of the parameter
· Press UP + Down to enter Programming Mode Method of VA Selection: Arithmetic /
· Press DOWN to edit next parameters till end VA Selection ua.uech VECH Vector harmonics /Vector
· Enter Password (default value 0000) after the configuration of last parameter display
· Blink indicates Edit Mode is ON
* Digital Output 1 disable disable, Wh, Under/Over - PF, V, A, F
screen will prompt “SAVE”, Display reads “Y” (YES)
· Press DOWN to decrement value · Press DOWN to change to “ ” (NO) * Threshold value 1000 0.001-999.9
0/9/8/7/6/5/4/3/2/1 · Press UP to save * Digital Output 2 2 disable disable, Wh, Under/Over - PF V, A, F
· Press UP to move to the next digit till 4th digit
If Password is correct, meter display reads 5.3. Display * Threshold value 2 2 1000 0.001-999.9
For Clear Mode move to step 5.2.1 First three digit : Parameter to edit * Digital Output Delay 3.000 1-180 sec
For Programming Mode move to step 5.2.2 4th to 7th digit : Parameter value
Baud Rate 9600 2400, 4800, 9600 19.2k
5.2.1.Clear Mode Programming Option/Range Parity Even Even/Odd/none
Parameter Default
· Press UP to Enter Clear Mode Display reads “ ” Slave Id sl1000 1.000 1 to 247
· Press UP to clear parameter. Display prompts “ ” ConFIG
Defines the 3P 4W PASSWORD 0000 0000 to 9999
· Press DOWN to change for “y” (yes) to clear values
power system 3P 4W 3P 3W Energy Resolution Resolution/Counter
· Press UP to clear configuration.
1 Phase Pulse Output ON Time p 0 2 5 0 . 0 250 50 to 500 msec
If password is incorrect, meter will display next parameter Energy Selection Wh Wh/VAh
but cannot be edited. 100V-999kV
PT Primary To set 33kV Set first four digits 5.4. Enabling and Disabling Auto Scrolling * optional for select product variants
(3300) as explained above press Press DOWN for 6 secs
415 UP/DOWN key to place decimal point
at appropriate location. Display Shows: EnbL. Au.
Letter K/M will indicate the Kilo/Mega. Again press DOWN for 6 sec
Display Shows: dSbL. Au.

6. Memory Map

Address Parameter Data type Address Parameter Data type Address Parameter Data type Address Parameter Data type

40101 Watts Total float 40123 PF B phase float 40137 VY B phase float 40151 Current R phase float
40103 Watts R phase float 40125 VA total float 40139 VB R phase float 40153 Current Y phase float
40105 Watts Y phase float 40127 VA R phase float 40141 VL N average float 40155 Current B phase float
40107 Watts B phase float 40129 VA Y phase float 40143 V R phase float 40157 Frequency float
40117 PF Avg (inst) float 40131 VA B phase float 40145 V Y phase float 40159 Wh float
40119 PF R phase float 40133 VL L average float 40147 V B phase float 40161 VAh float
40121 PF Y phase float 40135 VR Y phase float 40149 Current Total float 40217 Load Hours Unsigned long

7. Wiring Diagram 8. Mounting Dimensions


In case of complaint please contact

WC44000501A
+2.0 Steps for Mounting
90 - 0.0 CUSTOMER INTERACTION CENTRE (CIC)
Insert meter to panel
Received (Import) Delivered (Export) Received (Import) Delivered (Export) Received (Import) Delivered (Export) 1 TOLL-Free: 1800 233 5858, 1800 200 5858
without clamps
Telephone : 022 6774 5858
2 2
Load Line Load Line Load Line Insert both clamps email: cic@LNTEBG.com
1 3

+2.0
90 - 0.0

L&T Electrical & Automation


AMF IP AMF IP AMF IP
240V AC 240V AC 240V AC

Electrical Standard Products


L&T Business Park, Tower 'B' / 3rd Floor
3 Phase 4 Wire System 3 Phase 3 Wire System Single Phase System 54mm Saki Vihar Road, Powai Mumbai 400 072
3
4mm Website: www.Lntebg.com
Manufacturer assumes no responsibility for a hazard or
damage caused by incorrect or non-application of any of the
instructions attached herein. Under no circumstance shall 1.Features
Larsen & Toubro be liable for any consequential or resulting
injury or for loss, damage or expense directly or indirectly from · Accuracy class 1 as per IEC 62053-21, class 0.5, 0.5S as per IEC 62053-22
the use of this product. Sufficient care is taken to provide all · True RMS measurement
INSTRUCTION MANUAL information regarding the product but Larsen & Toubro does
not claim any responsibility for the damage caused by using the · Password protection provision
product directly or indirectly. Use according to the operating · Site selectable for 3 Phase 4 Wire, 3 Phase 3 Wire, 1 Phase
Digital Panel Meter instructions, professional practices, wiring rules, codes, safety
regulations applicable to the given installation. · Site programmable CT/PT ratio
Basic Multifunction Meter · Auto-scaling of kilo, mega & giga values
During normal operation of this instrument ,hazardous · Positive accumulation of active energy
4405 LED series voltages are present at the rear terminals, which can cause · Autoscrolling & freeze mode provision is available
injury or death. Installation ,disconnection or removal of the
meter should be carried out only by qualified, trained · User selectable energy measurement : Wh/VAh
personnel, after de-energizing connected circuits. Improper
installation , including improper grounding will void warranty.
Product warranty void if seal is broken.

2. LED Indication 3. Display of Parameters Total Watts 4. Technical Specification

Display Meaning PF Power Factor 3 Ph 4 W, 3 Ph 3 W, 1 Ph


Lag (ON)
Voltage Line to Line Active Energy Received Type of Type True RMS, 64 samples
Both on Mega measurement
Giga{ Kilo
230.5 L Voltage Line to Neutral
Load Hour per cycle 1 sec update
time
Power Factor R Phase/Y Phase/B Phase
5.000 A Voltage RY Phase
VA - R Phase/Y Phase/B Phase
Class 1 as per
IEC 62053-21
50.00 F Voltage YB Phase Measurement Class 0.5 as per
Voltage R / Y / B Phase
Voltage BR Phase accuracy IEC 62053-22
Communication Pulse Current R / Y / B Phase
ON
Average Current Class 0.5S as per
Watts R / Y / B Phase IEC 62053-22
To edit the To select the value Frequency Active energy received old 4 digit for instantaneous
value/Parameter or accept the value Display type LED
in programming in programming UA Total VA Load Hour Old & resolution & 6 digits for cumulative
mode mode

50 - 550 VLL Impulse voltage test ±6 kV as per IEC 62052-11


Insulation
PT Primary and Secondary user programmable AC voltage test 4 kV double insulation as per IEC 62053-21
Input voltage for LT and HT applications properties
Insulation resistance 500 V DC as per IS 13779
Burden: 0.2VA max per phase Operating temperature O
-10 C to +55 C
O

Measuring -/5A and -/1A site selectable Storage temperature O


-25 C to +70 C
O
Operating
circuit Current range from 10% to 120% of In (50mA-5A), conditions Humidity 5% to 95% relative humidity non-condensing
Input current Starting current : 0.4% of full scale
Recommended wire 2.5 sq mm
CT Primary and Secondary user Shock As per standard IEC 60068-2
programmable for LT and HT applications Mechanical Vibration 10 to 55 Hz, 0.15 mm amplitude
Frequency 40 - 70 Hz conditions
Casing Plastic mould protected to IP51 from front side
Aux voltage 80 - 300V AC/DC Measurement category CAT III
Auxiliary <5VA
circuit Aux burden Safety Pollution degree 2
Freq range 40 - 70 Hz Protection IP20 at terminals, IP51 on front
Test of power consumption as per IEC 62053-21 Product weight 300 gms
Electrical
Voltage dips and interrupts as per IEC 62053-21 Weight & Bezel dimension (W x H x D) 96 x 96 x 58 mm
requirements dimensions
Short time over current protection 10A max continuous, 20 times of In for 3 sec Panel cutout 90 x 90 mm +2-0
Fast transients burst test ±4 kV as per IEC 61000-4-4
Outputs Meter constant: 1250/(external CT ratio x PT ratio)
Immunity to ±8 kV air discharge, ±6 kV contact
electrostatic discharge discharge as per IEC 61000-4-2 Type RS485 port Modbus RTU
Electro- Radiated, Radio-frequency, Baud rate 2400, 4800, 9600, 19200 bps (site selectable)
10 V/m as per 61000-4-3
magnetic Electromagnetic field immunity test Parity Odd, Even, None
compatibility Immunity to electromagnetic HF Communication
10 V/m as per IEC 61000-4-6 Slave id 1 to 247 (programmable)
(EMC) fields through conducted lines
Surge immunity test ±6 kV as per IEC 61000-4-5 Isolation 2 kVAC isolation for 1 minute between
Rated power frequency magnetic fields 1 A/m as per IEC 61000-4-8 communication and other circuits
Emission Class B as per CISPR 22 Certifications CE, RoHS
5. Programming Mode · Press DOWN to decrement values or PT Secondary P.SEC 415.0 50V to 550V
5.1 Programming keys to select from available options CT Primary 5.000 0.5A - 99kA
· Press UP to accept the value of the parameter
To select Edit Mode and save parameter CT Secondary C.SEC 5.000 0.5A - 6A
· Press DOWN to edit next parameters till end
DOWN to decrement value or parameter after the configuration of last parameter display Yes/No
Reverse Lock no If YES it blocks energy accumulation in
screen will prompt “SAVE”, Display reads “YES” (YES) case the CT polarity reverse.
5.2 General Programming Guide · Press DOWN to change to “no” (NO)
· Press UP + Down to enter Programming Mode Method of VA Selection:
· Press UP to save VA Selection VA.SL VEC.H Arithmetic /Vector harmonics /Vector
· Enter Password (default value 0000)
· Blink indicates Edit Mode is ON Baud Rate 9600 2400, 4800, 9600 19.2k
· Press DOWN to decrement value 5.3. Display Parity Even Even/Odd/none
0/9/8/7/6/5/4/3/2/1 Slave Id 1.000 1 to 247
Row1: Options
· Press UP to move to the next digit till 4th digit PASSWORD 0000 0000 to 9999
If Password is correct, meter display reads
Row2: Parameter Energy Resolution Resolution/Counter
For Clear Mode move to step 5.2.1
For Programming Mode move to step 5.2.2 Pulse Output ON time 250 50 to 500 msec
Programming Energy Selection E . S E L Wh Wh/VAh
5.2.1.Clear Mode Default Option/Range
Parameter
· Press UP to Enter Clear Mode Display reads “SEt.CLr”
· Press UP to clear parameter. Display prompts “no” ConF
Defines the 3P 4W 5.4. Enabling and Disabling Auto Scrolling
· Press DOWN to change for “YES” (yes) to clear values power system Press DOWN for 6 secs
3P 4W 3P 3W
· Press UP to clear configuration. Display Shows: EnbL. AutO
1 Phase
Again press DOWN for 6 sec
If password is incorrect, meter will display next
100V-999kV Display Shows: dSbL. AutO
parameter but cannot be edited. To set 33kV Set first four digits
PT Primary (3300) as explained above press
5.2.2. Programming Mode 415 UP/DOWN key to place decimal point
P.p at appropriate location.
· Press DOWN to enter Programming Mode Letter K/M will indicate the Kilo/Mega.
· Press UP key to select the Edit Mode
 Blink indicates Edit Mode is ON

6. Memory Map

Address Parameter Data type Address Parameter Data type Address Parameter Data type Address Parameter Data type

40101 Watts Total float 40123 PF B phase float 40137 VYB phase float 40151 Current R phase float
40103 Watts R phase float 40125 VA total float 40139 VBR phase float 40153 Current Y phase float
40105 Watts Y phase float 40127 VA R phase float 40141 VLN average float 40155 Current B phase float
40107 Watts B phase float 40129 VA Y phase float 40143 V R phase float 40157 Frequency float
40117 PF Avg (inst) float 40131 VA B phase float 40145 V Y phase float 40159 Wh float
40119 PF R phase float 40133 VLL average float 40147 V B phase float 40161 VAh float
40121 PF Y phase float 40135 VRY phase float 40149 Current Total float 40217 Load Hours Unsigned long

7. Wiring Diagram 8. Mounting Dimensions


In case of complaint please contact

WL44050506A
+2.0
90 - 0.0 Steps for Mounting
CUSTOMER INTERACTION CENTRE (CIC)
Insert meter to panel
Received (Import) Delivered (Export) Received (Import) Delivered (Export) Received (Import) Delivered (Export) 1 TOLL-Free: 1800 233 5858, 1800 200 5858
without clamps
Telephone : 022 6774 5858
2 2
Load Line Load Line Load Line 1 Insert both clamps email: cic@LNTEBG.com
3

+2.0
90 - 0.0

L&T Electrical & Automation


AMF IP AMF IP AMF IP
240V AC 240V AC 240V AC

Electrical Standard Products


L&T Business Park, Tower 'B' / 3rd Floor
54mm
3 Saki Vihar Road, Powai Mumbai 400 072
3 Phase 4 Wire System 3 Phase 3 Wire System Single Phase System 4mm
Website: www.Lntebg.com
PRAGATI Instrument Transformers

RELIABLE
MEASUREMENT
& PROTECTION

www.pragtielectricals.com
ABOUT US

Pragati Electricals Pvt. Ltd. an ISO 9001-2008 certified company has been manufacturing wide range of Instrument Transformers
from 0.66 kV to 220 kV over last 35 years. Thousands of Instrument Transformers of our make are in service in various
applications like Power Generation, Transmission & Distribution Networks, Metering & Protection Circuits, Switchboards,
Metering Cubicles etc.

‘Pragati’ make Instrument Transformers are well-known for reliable measurement accuracy due to which in some laboratories
Pragati make CT’s & PT’s are even used as standards for calibration purpose.

‘Pragati’ has Three manufacturing plants with state-of-the-art design, production & testing facilities located at Thane, Rabale,
Murbad in the Thane, Navi Mumbai & Kalyan region of Maharashtra State of India.

INFRASTRUCTURE

Design & Engineering : Qualified & experienced engineering staff is trained


to communicate with customers & understand their requirement, so that
product manufactured shall meet not only technical specifications as per
required national / international standards but also specific needs of the
customers in terms of dimensions & other mechanical requirements.
Computer programms are used to perform Mechanical & Electrical
calculation to achieve highest accuracy in optimum design. Our engineers
are committed to accept modern & innovative concepts in product
designing by using modern computing tools available in the market.

Production Process : In ‘Pragati’ all production processes follow stringent


quality norms during each stage following are the modern manufacturing
facilities available at our works.

1. Core Manufacturing Facility


a) Toroidal Core manufacturing machines.
b) Distributed Gap Core manufacturing machine for efficient
performance of VT & Control Transformer.
c) Core annealing conveyor system machine for uniform heating &
faster delivery of cores.
2. Coil winding & taping machines.
3. PLC controlled Automatic Pressure Gelation casting machine for
manufacturing resin cast instrument transformers.
4. Vacuum drying & oil impregnation facility for manufacturing outdoor
oil cooled instrument transformers.

Testing & Quality Control : Our test laboratories are equipped to perform
acceptance tests of raw materials to finished product as per National &
International Standards. Latest equipments for automatic testing &
calibration of CTs, measurement of Partial Discharge & Dielectric Loss Factor
are used in our laboratories.
LOW TENSION INSTRUMENT TRANSFORMERS

‘Pragati’ manufactures all types of Indoor / Outdoor low tension current & voltage transformers

Low Tension CT’s


• IL 0.72/3 kV
• Ip Up to 5000 A
• Is = 5 or 1 A
• Ith Upto 50 kA
• Burden & Accuracy Class As Per IS, IEC, ANSI
(other standard on request)
• Tape Wound/Resin Cast Ring & Wound Primary Type
• Resin cast Embedded Bar Primary Type
• Bushing CTs for Power Transformers
• Slip on CTs for H.T. Switchgears
• Generator Busduct CTs
• Split Core Type
• Universal Auxiliary Transformer ( Multi Ratio CT )

Low Tension VT’s


• IL 0.72/3 kV
• Burden Upto 500 VA
• Accuracy Class As Per IS, IEC, ANSI
(other standard on request)
• Single or Three Phase
• Tape Wound / Resin Cast Type
• Isolation VT
• Residual Voltage Transformer (RVT).
• Phase Reversal VT

Special Purpose Low Tension Indoor CT’s & VT’s


• Summation CT.
• Core Balance Current Transformer.
• Precision Grade CT’s & VT’s.
• Interposing CT’s & VT’s.
• LT Control Transformer :
 Single or Three Phase
 Tape Wound / Resin Cast Type
 Dry Type Transformers – Up to 350 kVA with
class of insulation B, F, H according to
specifications.
 Isolation & Lighting Transformer : Up to 350 kVA
 Furnace & Rectifier Transformers : Up to 350 kVA

* We make wide range of Low Voltage Control Transformers with & without enclosure for various applications.
INDOOR EPOXY RESIN CAST INSTRUMENT TRANSFORMERS

‘Pragati’ offers indoor type Instrument Transformers in Epoxy Resin Cast up to 33 kV . Modern manufacturing process such as
Automatic Pressure Gelation method is used. All processes during casting are monitored by PLC, which gives excellent quality
product.

Indoor Epoxy Resin Cast Current Transformer


Indoor type current transformers are available in
following variation.
• Up to 33 kV
• Ip Up to 2500 A for Wound Primary Type & Up to
5000 A for Window Type
• Is = 5 or 1 A
• Ith up to 50 kA
• 1.2/50 µs LIV Up to 200 kVp
• Burden & Accuracy class as per IS, IEC, ANSI
(other standard on request)
• Block Type ( Post Type / Wound Type )
• Bar Type ( Embedded Bar )
• Window Type.

Indoor Epoxy Resin Cast VoltageTransformer


Indoor type voltage transformers are available in
following variations.
• Up to 33 kV
• Single pole VT
• Double pole VT
• Three phase VT
• Burden Up to 500 VA
• Voltage factor
1.2 Un continuous
1.5 Un 30s
1.9 Un 30s
1.9 Un 8h
• Accuracy & Protection Class as per IS, IEC, ANSI
(other standards on request)
• 1.2/50 µs LIV up to 200 kVp

‘Pragati’ manufactures VT’s with Distributed Gap Core for


better performance.

* We also make Resin Cast H.T. Control Transformars for Indoor & Outdoor applications.
OUTDOOR OIL COOLED INSTRUMENT TRANSFORMERS

‘Pragati’ offers Outdoor Oil Cooled type current transformers up to 220 kV in Dead Tank version, up to 132 kV both in Live Tank
& Dead Tank versions & voltage transformers up to 132 kV.
High quality oil paper insulation is achieved by using oil paper impregnation at controlled vacuum & temperature treatment.
Inside system is sealed from atmosphere .
Contraction & expansion of oil with temperature variation is taken care by stainless steel bellow / nitrogen cushioning.
Outer insulation consist of high quality porcelain insulators having standard /extended creepage distance . On request composite
insulator consisting fiber glass reinforced pipe & silicon rubber screens can be provided instead of porcelain insulator.

Main Features
Fully Type Tested as per IS, IEC at NABL Accredited Laboratories. Design passes Seismic withstand capability test at 0.5 g peak.

Outdoor Oil Cooled Current Transformer


• Up to 220 kV
• Construction Live Tank or Dead Tank Dead Tank Design Live Tank Design
• Ip up to 3600A for Live Tank Design & up to 1200A
for Dead Tank Design
• Is = 5 or 1 A
• Upto 5 Cores
• Ith up to 40 kA
• Burden & Accuracy class as per IS, IEC, ANSI
(other standard on request)
• 1.2/50 µs LIV up to 1050 kVp
• Ingress Protection of Secondary Terminal Box : IP 55

Outdoor Oil Cooled Voltage Transformer


• Up to 132 kV
• Single or Double pole VT (only upto 33 kv)
• Burden Up to 500 VA
• Voltage factor
1.2 Un continuous
1.5 Un 30s
1.9 Un 30s
1.9 Un 8h
• Accuracy & Protection Class as per IS, IEC, ANSI
(other standard on request)
• 1.2/50 µs LIV up to 650 kVp
• Ingress Protection of Secondary terminal Box : IP 55

Other Oil Cooled Products


• Outdoor Oil Cooled Combined CT/ PT Unit
• Outdoor Oil Cooled RVT
• Outdoor Oil Cooled 3 Phase VT.
• Oil Cooled HT & LT Control Transformers
INDOOR/ OUTDOOR CT/ PT METERING CUBICLE (KIOSK)

With the growing awareness of accurate metering of energy & wide sprade activities undertaken by Electric Energy Supply
companies the need has been felt for good quality reliable Metering Unit / Cubicles / Kiosk up to 33 kV.

• Up to 33 kV Features
• Indoor or Outdoor 1. Pilfer Resistant design .
• 1.2/50 µs LIV up to 170 kVp 2. Outdoor Type Metering Cubicle is completely
• Ref. Standard IS, IEC (other standard on request) Weather & Dust Proof.
• CT Specification 3. Very High Export Quality Resin Cast Instrument
 Ip up to 300 A Transformers of our own make used inside cubicles.
 Is = 5 or 1 A 4. No Exposure of Live Parts.
 Burden 5 ~ 20 VA 5. Available for 3 Ph-3 Wires / 3 Ph-4 Wires Measuring
 Ith Up to 26.2 kA Systems.
 Accuracy Class 0.2 / 0.5 6. Electronic Lock Arrangement (on request).
(0.2 S / 0.5 S on special request) 7. Type tested at NABL accredited laboratory.
• VT Specification
 Burden up to 100 VA / Phase
Advantages
 Accuracy Class 0.2 / 0.5
1. Excellent Quality.
 V.F. up to 1.5 for 30 sec
2. Fastest Delivery due to our own CTs / PTs &
Insulators etc.
3. Excellent After sales service.
4. Our own testing & calibration facility.

33 kV Indoor Metering Cubicle 33 kV Outdoor Metering Cubicle

1400

CT/VT CHAMBER
METER CHAMBER

CT/VT CHAMBER
1900

Danger Board

Rating Plate

1350
1400 1430
Incoming Outgoing
Cable Entry Cable Entry 1520
FRONT VIEW

FRONT VIEW

22 kV Indoor / Outdoor Metering Cubicle

Incoming Outgoing

“E”

1100±5
2150
FRONT VIEW
Incoming Outgoing
Cable Entry Cable Entry

*We also make Outdoor Oil Cooled Combined CT/PT Metering Sets for 3 Phase 3 Wires or 3 Phase 4 Wires applications.
OUTDOOR CYCLOALIPHATIC RESIN CAST INSTRUMENT TRANSFORMERS

‘Pragati’ manufactures Outdoor Cycloaliphatic Instrument Transformers up to 33 kV. Following are advantages & features.

Features
1. Compact Design
2. Weather & UV Resistant Insulation
3. Type tested at NABL accredited laboratory

Advantages
1. Maintenance free
2. Minimal risk of transit damage
3. Competitive price
4. Low lead time
5. High Mechanical strength

Outdoor Cycloaliphatic Resin Cast CT


• Up to 33 kV
• Ip Up to 1250 A
• Burden &Accuracy class as per IS, IEC, ANSI
(other standard on request)

Outdoor Cycloaliphatic Resin Cast VT


Indoor Type voltage transformers are available in
following variations.
• Up to 33 kV
• Single or Double pole VT
• Burden Up to 500 VA
• Accuracy & Protection Class as per IS, IEC, ANSI
(other standard on request)

SPECIALITY TRANSFORMERS

A ) High Current Ring Type Current Transformer


(Generator Bus Duct CT) up to 22 kV & 30000 A
B) High Current CT’s with Split core arrangement for
furnace duty Ip : Up to 60,000 Amp.
C) DC Current & Voltage Transformers up to 50,000
A & 3000 Volts
D) Epoxy Resin Cast Dry Type Transformers up to 22
kV & 85 kVA for applications such as Neutral
Grounding Transformer, Earthing Transformers,
Control Transformer.
Global Presence
U.S.A. Ethiopia Azerbaijan Indonesia
Germany Kuwait Vietnam Lebanon
Turkey Saudi Arabia Jordan Qatar
Egypt Sultanate of oman Srilanka Singapore
Kenya United Arab Japan Korea
Nigeria Emirates Malaysia Abu Dhabi
Ghanna Philipines Hong Kong Dubai
Zambia Bahrain Nepal

PRAGATI ELECTRICALS PVT. LTD.


Registered Office (RO) / Marketing Office (MO) and Rabale Works (RW)
R-230, TTC MIDC Industrial Area, Rabale, Navi Mumbai - 400 701, Maharashtra, India.
Phone : 91- 22- 3092 3500 (100 Lines) Fax : 91- 22- 2769 7225

Murbad Works (MW)


Plot No. A-2/16, MIDC Industrial Area, Murbad - 421 401. (Via Kalyan Rly. Stn.) Dist. : Thane, Maharashtra, India.
Phone : 91- 2524 - 660100 (100 Lines)

Head Office (HO) and Thane Works (TW)


280/3, 2nd Pokhran Road, Thane - 400 610. Maharashtra, India.
Phone : 91- 22- 3985 3500 (100 Lines) Fax : 91- 22- 2173 0945

E-mail : marketing@pragatielectricals.com / Website : www.pragatielectricals.com


3SB5 Datasheet

3SB5
Indicating lamps and push buttons

www.siemens.co.in
Index
Device Types Pg 03

Pg 04

Overview Pg 05

Pg 06

Pg 13

Pg 15

Pg 19

2
Device Types

Actuators Indicators Enclosures

Push Button

Mushroom Head Compact

Key Modular Enclosures

Selector Wide Band

Twin Pushbuttons

3
Contact Reliability SIGUT® Termination Snap Mounting

Contacts Blocks LVGP In Built Surge suppressors

4
Overview

Design

Standards

Connection Method

5
Pushbutton

Pushbuttons with holder


Opaque normal Red 3SB50 00-0AC01
3SB50 00-0AE01
3SB50 00-0AF01
3SB50 00-0AG01
3SB50 00-0AD01
3SB50 00-0AB01

Opaque raised Red 3SB50 00-0LC01


3SB50 00-0LE01
3SB50 00-0LF01
3SB50 00-0LG01
3SB50 00-0LD01
3SB50 00-0LB01

Illuminated normal Red 3SB50 01-0AC01-0PQ0


3SB50 01-0AE01-0PQ0
3SB50 01-0AL01-0PQ0
3SB50 01-0AF01-0PQ0
3SB50 01-0AG01-0PQ0
3SB50 01-0AD01-0PQ0
3SB50 01-0AH01-0PQ0

Illuminated raised Red 3SB52 18-0LC01-0PQ0


3SB52 18-0LE01-0PQ0
3SB52 18-0LL01-0PQ0
3SB52 18-0LF01-0PQ0
3SB52 18-0LG01-0PQ0
3SB52 18-0LD01-0PQ0
3SB52 18-0LH01-0PQ0

Mushroom pushbuttons with holder


Mushroom pushbuttons, Ø 40 mm 3SB50 00-1NB01
momentary Red 3SB50 00-1NC01

Mushroom pushbuttons, Ø 40 mm 3SB50 00-1CB01


push to trip, turn to release

Mushroom pushbuttons for emergency stop


Mushroom pushbuttons with 1NC Red 3SB52 03-0UC01
push to trip, turn to release

Mushroom pushbuttons, Ø 40 mm Red 3SB50 00-0UC01


push to trip, turn to release
Mushroom

Mushroom pushbuttons, Ø 40 mm Red 3SB50 00-0TC01


push to trip, key to release

6
Key Switches

Key-operated switches with holder


Key-operated switches with 2 keys & 2 switch positions
3SB50 00-4AC01

3SB50 00-4AA01

3SB50 00-4AB01

3SB50 00-4TA01

3SB50 00-4TC01

Key-operated switches with 2 keys & 3 switch positions


3SB50 00-4HA01

3SB50 00-4HC01

3SB50 00-4HB01

3SB50 00-4JA01

Selector switches with holder


2 position
Selector switches with 2 switch positions
Opaque 3SB50 00-2AB01
Maintained Red 3SB50 00-2AC01
Opaque 3SB50 00-2BB01
Momentary Red 3SB50 00-2BC01

Illuminated Red 3SB50 01-2AC01


Maintained 3SB50 01-2AE01
3SB50 01-2AF01
3SB50 01-2AD01
3SB50 01-2AH01
Illuminated Red 3SB50 01-2BC01
Momentary 3SB50 01-2BE01
3SB50 01-2BF01
3SB50 01-2BD01
3SB50 01-2BH01
3 position
Selector switches with 3 switch positions
Opaque 3SB50 00-2DB01
Maintained Red 3SB50 00-2DC01
Opaque 3SB50 00-2EB01
Momentary Red 3SB50 00-2EC01

Illuminated Red 3SB50 01-2DC01


Selector

Maintained 3SB50 01-2DE01


3SB50 01-2DF01
3SB50 01-2DD01
3SB50 01-2DH01
Illuminated Red 3SB50 01-2EC01
Momentary 3SB50 01-2EE01
3SB50 01-2EF01
3SB50 01-2ED01
3SB50 01-2EH01

7
Twin Push button

Twin pushbutton with holder


Opaque twin 3SB52 01-7EC01
pushbutton with 1NO & 1NC

Opaque twin 3SB50 00-7EC01


pushbutton modular

Illuminated twin1) 3SB52 34-7EC01


pushbutton with 1NO & 1NC

Illuminated twin 3SB50 01-7EC01


pushbutton modular

Contact blocks for front plate mounting


Contact blocks with one contact
3SB54 00-0B

3SB54 00-0C

Contact blocks with 2 contacts


3SB54 00-0A

3SB54 00-0E

3SB54 00-0F
Contact Blocks

8
Compact LED indicating lamp
Indicators

Red 3SB52 85-6HC01


3SB52 85-6HE01
3SB52 85-6HL01
3SB52 85-6HF01
3SB52 85-6HG01
3SB52 85-6HD01
3SB52 85-6HH01
@
Red 3SB52 85-6HC13
3SB52 85-6HE13
3SB52 85-6HL13
3SB52 85-6HF13
3SB52 85-6HG13
3SB52 85-6HD13
3SB52 85-6HH13
Red 3SB52 85-6HC02
3SB52 85-6HE02
3SB52 85-6HL02
3SB52 85-6HF02
3SB52 85-6HG02
3SB52 85-6HD02
3SB52 85-6HH02
@
Red 3SB52 85-6HC04
3SB52 85-6HE04
3SB52 85-6HL04
3SB52 85-6HF04
3SB52 85-6HG04
3SB52 85-6HD04
3SB52 85-6HH04
Red 3SB52 85-6HC03
3SB52 85-6HE03
3SB52 85-6HL03
3SB52 85-6HF03
3SB52 85-6HG03
3SB52 85-6HD03
3SB52 85-6HH03
@
Red 3SB52 85-6HC05
3SB52 85-6HE05
3SB52 85-6HL05
3SB52 85-6HF05
3SB52 85-6HG05
3SB52 85-6HD05
3SB52 85-6HH05
Wide band compact LED indicating lamps
Red 3SB52 35-6HC14
3SB52 35-6HE14
3SB52 35-6HL14
3SB52 35-6HF14
3SB52 35-6HG14
3SB52 35-6HD14
3SB52 35-6HH14
Modular indicating lamps
Red 3SB52 01-6BC00
3SB52 01-6BE00
3SB52 01-6BL00
3SB52 01-6BF00
3SB52 01-6BG00
3SB52 01-6BD00
3SB52 01-6BH00

9
Illumination module with integrated LED
Red 3SB54 00-7CC
3SB54 00-7CE
3SB54 00-7CL
3SB54 00-7CF
3SB54 00-7CG*
3SB54 00-7CD
Red 3SB54 00-7EC
3SB54 00-7EE
3SB54 00-7EL
3SB54 00-7EF
3SB54 00-7EG*
3SB54 00-7ED
@
Red 3SB54 00-7DC
3SB54 00-7DE
3SB54 00-7DL
3SB54 00-7DF
3SB54 00-7DG*
3SB54 00-7DD
Red 3SB54 00-7TC
3SB54 00-7TE
3SB54 00-7TL
3SB54 00-7TF
3SB54 00-7TG*
3SB54 00-7TD
@
Red 3SB54 00-7HC
3SB54 00-7HE
3SB54 00-7HL
3SB54 00-7HF
3SB54 00-7HG*
3SB54 00-7HD
Illumination module with BA9s LED
Red 3SB54 00-8CC
3SB54 00-8CE
3SB54 00-8CF
3SB54 00-8CD
#
Red 3SB54 00-8FC
3SB54 00-8FE
3SB54 00-8FF
3SB54 00-8FD
#
Red 3SB54 00-8SC
3SB54 00-8SE
3SB54 00-8SF
3SB54 00-8SD

3SB54 00-6CC
3SB54 00-6FH
3SB54 00-6LH

10
Accessories and spare parts

Pusher caps and lenses


Normal opaque Red 3SB59 10-0AC
3SB59 10-0AE
3SB59 10-0AF
3SB59 10-0AG
3SB59 10-0AD
3SB59 10-0AB
Raised opaque Red 3SB59 10-0BC
3SB59 10-0BE
3SB59 10-0BF
3SB59 10-0BG
3SB59 10-0BD
3SB59 10-0BB
Normal illuminated Red 3SB59 10-0CC
3SB59 10-0CE
3SB59 10-0CR
3SB59 10-0CF
3SB59 10-0CG
3SB59 10-0CD
3SB59 10-0CH
Raised illuminated Red 3SB59 10-0DC
3SB59 10-0DE
3SB59 10-0DR
3SB59 10-0DF
3SB59 10-0DG
3SB59 10-0DD
3SB59 10-0DH
Lenses Red 3SB59 10-1PC
3SB59 10-1PE
3SB59 10-1PR
3SB59 10-1PG
3SB59 10-1PD
3SB59 10-1PH

Lamps
3SB59 02-6C
3SB59 02-6D

Red 3SB59 02-3FK


3SB59 02-3GK
3SB59 02-3JK
3SB59 02-3HK

Protective caps1), degree of protection IP67


Protective caps 3SB59 02-0AK

Protective caps 3SB59 02-0AN

11
Holders for commanding and signalling elements
3SB59 12-0BA

3SB59 11-1AA

Inscription labels
3SB59 21-0AD

3SB59 21-0AB

Inscription plates
3SB59 01-2EL
3SB59 01-2EK
3SB59 01-2EB
3SB59 01-2EC
3SB59 01-2ED
3SB59 01-2EE
3SB59 01-2EF
3SB59 01-2ES
3SB59 01-2ER
Reverse 3SB59 01-2EG
3SB59 01-2AA
Trip 3SB59 01-2EA

Twin push button spares and accessories


3SB59 12-0BB

Other accessories
3SB59 21-0AE

Lamp extractors 3SB59 02-2AD

3SB59 11-1BA

3SB59 02-0AA

3SB59 12-0AN

3SB59 12-0BC

12
Holders Contact and lampholders

Connection methods Mounting

13
Pushbuttons and indicating lamps
Rated insulation voltage Ui

Rated operational voltage Ue

Back-up HRC fuse rating

Mechanical life 10 x 106 cycles


3 x 106 cycles
3 x 105 cycles
Electrical life
6

Switching frequency
Voltage limits
Degree of protection IP65
IP65

IP65
IP65
IP54
IP65

Permissible service temperature range


Terminal capacity

Continuous current, rated operational current Ie, contact blocks


Ie Ie e

1
1 1 1
1 1 1

3 3
3 3
Key 3 3
3 3

14
Overview

Enclosures

Standards

15
Metal enclosures
1 3SB58 01-8AA3

1 3SB58 01-8AN3

1 3SB58 01-8AM3

3SB58 02-8AC3

3SB58 02-0AE3

3 3SB58 03-8AH3

Plastic enclosures
1 3SB58 01-7AA3

1 3SB58 01-7AN3

1 3SB58 01-7AM3

3SB58 02-7AC3

3SB58 02-7AE3

3 3SB58 04-7AG3

16
Pendant mounting: Metal
3SB58 22-8AC3

3 3SB58 23-8AH3

Pendant Mounting: Plastic


1 3SB5821-7AA3

3SB5822-7AC3

3 3SB5823-7AH3

Empty enclosures

Empty enclosures, plastic


1 to 3 command positions, 1 3SB58 01-0AC3
4 and 6 command positions 3SB58 02-0AC3
3 3SB58 03-0AC3
4 3SB58 04-0AC3
6 3SB58 06-0AC3
1 3SB58 01-0AD3

Empty enclosures, metal


1 to 3 command positions 1 3SB58 01-4AC3
3SB58 02-4AC3
3 3SB58 03-4AC3

17
Lampholders and contact blocks

Screw terminals

BA9s lampholder
BA 9s lampholders
3SB54 20-2PF0
3SB54 20-2PL0

Contact blocks with one contact


Contact blocks with one contact
3SB54 20-0B

3SB54 20-0C

Accessories
Set of 11 labels 3SB59 01-3EA

3SB59 02-2BX

18
Project planning aids

19
20
1

3 150
4*
6*

21
22
23
Your partners
Ahmedabad Chennai Jaipur Mumbai

Nagpur
Baroda Coimbatore Jamshedpur

Kolkata
Gurgaon Pune
Bengaluru

Lucknow
Bhubaneswar Hyderabad Vishakhapatnam

Chandigarh

Territory managers:
Agra Haridwar Maraimalainagar Renukoot

Hospet Meerut Rourkela


Aurangabad

Belgavi
Mehsana
Hosur Rudrapur

Mysore

Hubli
Salem
Bharuch

Naidupeta
Jalandhar
Siliguri

Bhilai

Jodhpur
Nashik

Sonepat
Bhopal
Kanpur

Neemrana
Sriperumbudur
Khopoli
Boisar

Patna Surat

Cochin
Kolhapur

Pondicherry Trichy

Kota
Durgapur
Trissur
Raipur

Ludhiana
Gandhidham
Udaipur
Rajkot

Ludhiana
Gorakhpur
Vapi

Ranchi

Madurai
Guwahati
Vijayawada

www.siemens.co.in
Catalogue Cum Technical Specification
Power Saver LT Current Transformers & Bus Bar Supports.
CURRENT TRANSFORMERS

S alie nt F eatu res CURRENT TRANSFORMERS


D escrip tio n stick er w it h b ar co d e to en su re th at each C T h as p ass ed t h ro u gh all the te st in g pro ced u re s,
als o t race ability o f each C T
In d ivid ual Test C ertificat e w ith e ach CT
S tu d ty p e brass term in a ls fo r firm co nn ect io ns
Tran sp aren t P o ly carb onate sh ro ud w ith sea lin g p rov is io n fo r p ro te ct io n aga inst t ou ch a nd tem pe r
U se of h igh q uality CR GO Silico n s tee l co res , h avin g lo w relu ctan ce & lo w iro n lo sses
In h ou s e co re m an u factu ring to en su re co re q u ality an d d esire d B-H p aram et ers

NOTE ON CURRENT TRANSFORMER


Current Transformer
It transforms the high value current in primary circuit to low value current (e.g. 1A, 5A) in secondary circuit in respective
proportion. The ratio of primary current to secondary current is called CT ratio.
Application
To reduce the line current, to isolate & protect measuring instruments meters, relays etc. from direct line
Burden
Accuracy of a CT mainly depends upon the % of rated current & % of rated burden on it e.g. 100/5 5VA class 1.0 CT
_ 1%
At 5 VA if primary current =100 A, Then sec. current should be 5A +
If burden or rated current increases or decreases from it's rated value, the percentage deviation increases resulting
in poor accuracy class.
Accuracy Class
It is the accuracy of transformation of primary current to secondary current
e.g. 100/5 5 VA CT at 5VA if Primary current =100A
For Class 1.0 secondary current should be 5 +_ 1% i.e. 4.95-5.05 A
For Class 0.5 secondary current should be 5 +_ 0.5 % i.e. 4.975 -5.025 A
Measuring CTs are designed to use with Indicating, Measuring Instruments.
Protection CTs are designed to use with protective relays. These CTs are designed to comply its class of accuracy at 5 to 20
times primary current circuit. Three basic types are 5 P 5, 5 P 10 & 5 P 20 where 5 P shows Accuracy class & 5, 10, 20 shows
Accuracy Limit Factor i.e. 5, 10 & 20 times of primary rated current respectively
Difference between Measurement & Protection CT
Sec. current    Primary current till saturation (A CT is suppose to saturate if the secondary current does not increase in
proportion of primary current & becomes almost constant)
For Measuring CTs saturation current = 2 to 3 times of rated pri. Current
For Protection CTs saturation current = 5 to 20 times of rated pri. Current
Measurement / Protection CTs can be distinguished / checked by injecting current in its primary and corresponding
secondary current
PS class CT
These are Protection CTs for Special Purpose applications e.g. Distance protection systems, Balance protection system
Specification required for PS class CT
Knee point voltage
Max. exciting current
Turn Ratio
CT Selection (Measuring/Protection/PS)
CT Should be selected as per its application else it may cause malfunctioning of measuring /protection relays and hence
may affect the whole protection scheme.
If a measuring CT is selected in place of protection CT, during the fault when a large current
Protection CT
will flow through the primary i.e. 5 to 20 times of the rated primary, at a value of 2-3 times
of primary rated current, the CT will saturate and sec. current will become almost
constant and will not increase further in proportion of primary current. Measuring CT
Since the protective relay is set at higher value of sec. current, it will not actuate
and circuit breaking devices will not operate.

PS Class CTs are designed for specific applications as per their knee point voltage,
max, exciting current, Turn Ratio so, use of general protection CT may cause
malfunctioning of relays Ipri.
CURRENT TRANSFORMERS

RESIN CAST CURRENT TRANSFORMER


ACCURACY CLASS 1.0, SECONDARY 5A
M5
RESIN CAST WOUND PRIMARY (WPL) LTCTs Brass Stud

Primary Current Primary Brass


S. No. A B C D Stud. Size
(AMP)
1 2.5-25 70 55 100 100 M8
OB 5X10
2 30-80 70 55 100 100 M8 /Nos. 04

3 100 70 55 100 100 M 10

RESIN CAST RING & RECTANGULAR BAR PRIMARY (BPL) LT CTs


Primary OD Height Mounting
S. ID
Current TYPE 5VA 10/15 VA 5VA 10VA 15VA Hole Centre
No. M5
(AMP) A/A*A1 B*C B*C D D D E Brass Stud

1 100 Ring 30 90*90 90*90 40 40 * 65


10 mm
2 150 Ring 30 90*90 90*90 40 40 * 65 ΦA

3 200 Ring 35 80*80 80*80 40 40 50 55


4 250 Ring 45 90*90 90*90 40 40 50 65
5 300 Ring 55 90*90 90*90 40 50 50 65
6 400 Ring 55 90*90 90*90 35 40 40 65 M5X8
7 500 Ring 55 90*90 90*90 35 35 40 65 Insert

8 600 Ring 55 95*95 95*95 35 35 40 70


9 800 Ring 70 105*105 105*105 45 45 45 85
10 800 Rectangular 105*25 * 155*65 * 40 40 40 M5
Brass Stud
11 1000 Rectangular 105*25 * 155*65 * 40 40 40
12 1200 Rectangular 105*40 * 155*80 * 40 40 60 10 mm
13 1500 Rectangular 105*40 * 155*80 * 40 40 60
14 1600 Rectangular 105*40 * 155*80 * 40 40 60
15 2000 Rectangular 155*50 * 215*95 * 40 40 60
16 2500 Rectangular 155*50 * 215*95 * 40 40 60
17 3000 Rectangular 155*80 * 215*130 * 40 40 106 M5X8
18 3200 Rectangular 155*80 * 215*130 * 40 40 106 Insert

19 4000 Rectangular 155*80 * 215*130 * 40 40 106 All Dimensions are in mm


20 5000 Rectangular 230*80 * 310*160 * 40 40 100
21 6000 Rectangular 230*80 * 310* 160 * 40 40 100

TAPE WOUND RING & RECTANGULAR BAR PRIMARY (BPL) LT CTs


Primary
S. No. Current TYPE ID
(AMP)

1 50 Ring 20
2 60 Ring 20
3 75 Ring 20
4 100 Ring 30
5 150 Ring 30
6 200 Ring 35
7 250 Ring 45
8 300 Ring 55
9 400 Ring 55
10 500 Ring 55
11 600 Ring 55
12 800 Ring 70
13 800 Rectangular 105*25
14 1000 Rectangular 105*25
15 1200 Rectangular 105*40
16 1500 Rectangular 105*40
17 1600 Rectangular 105*40
18 2000 Rectangular 155*50
19 2500 Rectangular 155*50
20 3000 Rectangular 155*80
21 3200 Rectangular 155*80
22 4000 Rectangular 155*80
23 5000 Rectangular 230*80
24 6000 Rectangular 230*80
Remarks:-Up to 80A Tape wound CT Accuracy class shall be 5.0.
Note:- Please consider the cost of Ct’s with Sec. /1A as (above LP+15%)
CT'S ARE ALSO AVAILABLE IN ANY OTHER ID & ACCURACY CLASS AS PER CUSTOMER SPECIFICATION.
CURRENT TRANSFORMERS

ABS ENCAPSULATED
Salient Features
ABS case housing having working temp. 130 °C
DIN Rail mounting provision in WPL CTs hence easy mounting, saving of man power & time.
Provision for mounting clamp and screw to hold BPL CT with busbar
Sealing Provision in BPL CTs for protection against temper
Light weight , better finish & dimensional stability
Stud type brass terminals for firm connections
WOUND PRIMARY (WPL) LTCTs
Primary Current Primary Brass
S. No. A B C D Stud. Size
(AMP)
1 2.5-25 70 55 100 80 M8
2 30-80 70 55 100 80 M8
3 100 70 55 100 80 M 10

RING BAR PRIMARY (BPL) LT CTs


Primary OD Height
S. ID
Current TYPE 5VA 10VA 5VA 10VA
No.
(AMP) A B*C B*C D D E
1 100 Ring 30 100*90 100*90 45 45 128
2 150 Ring 30 100*90 100*90 45 45 128
3 250 Ring 55 100*90 100*90 45 45 128
Ø
4 300 Ring 55 100*90 100*90 45 45 128
5 400 Ring 55 100*90 100*90 45 45 128
6 500 Ring 55 100*90 100*90 45 45 128
7 600 Ring 55 100*90 100*90 45 45 128

Salient Features CONTROL & POTENTIAL TRANSFORMER


Description sticker with bar code to ensure the traceability of each transformer
Casting with Epoxy Resin for better mechanical /electrical strength & higher thermal insulation class
Stud type brass terminals for firm connections
Transparent Poly carbonate shroud with sealing provision for protection against touch and temper
Use of high permeable iron core, Lowlosses & Low Noise level design to maximize the saving
Control Transformers are used in switchgear and control gear to supply power to control or auxiliary equipments not intended
for direct connection to the main circuit. These are available in preffred ratings primary-240V, 415V and Secondary-
24V,48V,100V & 240 V, 25VA to 5kVA.
PTs are used with electrical measuring instruments and protective devices. These are available in single phase & three phase, 25
to 100VA.
Step Down Control Transformer Potential Transformer Single Phase
VA Rating VA Rating

25 25
50 50
100 100
150
200
250
300
400 Potential Transformer Three Phase Star/Star
500
VA Rating
750
1000 25
1250 50
1500 100
2000
2500
5000
BUSBAR SUPPORTS & INSULATORS

MOULDED SUPPORTS
Salient Features
 Better Fault Level in comparison with SMC.  Extra durability.
 Faster assembly, Hence time saving.  Push Fit type fitment.
 Better Strength due to more gripping area.  Compact & Unique design.
 Inventory management is easier.  Better Class of Flammibility.
 Lighter in weight due to less specific Gravity.  Hardware & Manpower saving.

Values
Properties Units
SMC Moulded
**
Short Circuit KA 65 80
Dielectric Strength KV/mm 11 26
Flammability Self extingushing FV0

Dimensions
Bus Bar Product Code (in mm) Std. Qty
A B C D E F per box

6mm x 3run MAMS-306 52.7 12.4 8 48.5 6.7 5.7 50


6mm x 6run MAMS-606 89.9 12.4 8 85.7 6.7 5.7 50
10mm x 3run MAMS-310 72 13 12.5 67.5 10.7 9.2 50
10mm x 4run MAMS-410 92 13 12.5 87.5 10.7 9.2 50
12mm x 2run MAMS-212 65 13 12.5 60.5 12.8 11.2 50
12mm x 4run MAMS-412 113 13 12.5 108.5 12.8 11.2 50
** Hole for Mounting should not be more than 8.7mm Dia.

Dimensions
Bus Bar Product Code (in mm) Std. Qty
per box
A B C D N Z Y Y1
10mm x 4run MAMS-FP-365X10 10.7 365 335 40 10.7 73 73 73 36
10mm x 4run MAMS-FP-415X10 10.7 415 385 40 10.7 80 87.5 87.5 36
12mm x 4run MAMS-FP-365X12 12.7 365 335 40 12.7 73 73 73 36
12mm x 4run MAMS-FP-415X12 12.7 415 385 40 12.7 80 87.5 87.5 36
6mm x 4run MAMS-FP-365X6 6.7 365 335 40 6.7 73 73 73 36
6mm x 4run MAMS-FP-415X6 6.7 415 385 40 6.7 80 87.5 87.5 36
10mm x 3run* MAMS-TPN-365X10 10.7 365 335 40 6.7 73 73 73 36
10mm x 3run* MAMS-TPN-415X10 10.7 415 385 40 6.7 80 87.5 87.5 36
12mm x 3run* MAMS-TPN-365X12 12.7 365 335 40 6.7 73 73 73 36
12mm x 3run* MAMS-TPN-415X12 12.7 415 385 40 6.7 80 87.5 87.5 36
* With 6mm x 1run for Neutral
BUSBAR SUPPORTS & INSULATORS

SMC & DMC BUSBAR SUPPORTS & INSULATORS


Salient Features
High die electric ,mechanical strength & temperature withstand capacity
Inserts are made of EN1A having better tensile strength as compared to MS & Brass
(e.g. ENIA- 600 MPa, MS-300 MPa, Brass – 150 MPa )
Insulators are available in SMC suitable up to 80KA (CPRI Tested) and DMC Suitable up to 25KA
Identification of mfg. / size on each support
Less combinations of mounting hole center to center distances, for common mounting
Matrix offers hexagonal insulators having below mentioned merits
o More creepage distance hence longer travel path for electric arc over surface
o Symmetrical on both ends hence equal stress on both ends
o Hexagonal Rib in center for holding the insulator to ensure proper tightness fromboth ends

NOTE ON SMC & DMC SUPPORTS & INSULATORS


All Switch gear & Electrical panels are combination of current carrying conductors & non current carrying structure. To separate
& support the current carrying busbars from the structure, busbar supports & Insulators are used. These supports / insulators
should be designed to bear electrical & mechanical stress during the normal & fault conditions. They should also comply other
features like Nonhygroscopic, Fire Retardant, Chemical & Corrosion Resistance
Matrix busbar supports & insulators are made of SMC ( Sheet Moulded Compound ) / DMC ( Dough Moulded Compound ) ,
manufactured with a combination of resin and other additives under controlled temperature and pressure, to produce
components with excellent alround properties and characteristics

Hexagonal Insulators A/F

Dimension in mm Normal Standard


Product Qty.
Insert Voltage
code
AC/DC Per Box
A/F R Hb H ΦR
MH 630 M6 34 25 10 30 600/750 100
MH 840 M8 35 28 15 40 1000/1200 100 Hb
MH 1050 M10 46 36 20 50 1200/1500 50
H

Conical Insulators

Dimension in mm Normal Standard HEX-BUSH


Product ΦRt
Insert Voltage Qty.
code
AC/DC Per Box
Rt Rb Hb H
MC 630 M6 25 30 10 30 600/750 200
MC 830 M8 25 30 10 30 600/750 200
MC 840 M8 33 40 15 40 1000/1200 100
MC 1040 M10 33 40 15 40 1000/1200 100 ΦRb
MC 1050 M10 40 50 20 50 1200/1500 50
MC 1250 M12 40 50 20 50 1200/1500 50
MC 1060 M10 42 60 20 60 1500/1800 25
MC 1260 M12 42 60 20 60 1500/1800 25

L-Support
Standard
Height (H) mm Product code Qty.
Per Box
60 ML 60 160
85 ML 85 125
100 ML 100 100
125 ML 125 80

* Conical & Hexagonal insulators (SMC) will be available in ivory colour.


BUSBAR SUPPORTS & INSULATORS

Finger Supports
Dimension Standard
Product
Busbar Qty.
code
A B C D E F Per Box

6mm x 1run M106 W 7.0 60 32 14 10 - 100


10mm x 1run M110 W 11.2 60 32 14 10 - 100
12mm x 1run M112 W 13.2 60 32 14 10 - 100
6mm x 1run M106 K 7.0 70 32 20 16 - 50
10mm x 1run M110 K 11.2 70 32 20 16 - 50
12mm x 1run M112 K 13.2 70 32 20 16 - 50
6mm x 1run M106 S 7.2 50 22 14 10 - 120
10mm x 1run M110 S 11.5 50 22 14 10 - 120
12mm x 1run M112 S 13.2 50 22 14 10 - 120

Dimension Standard
Product
Busbar Qty.
code
A B C D E F Per Box

6mm x 2run M206 W 7.0 60 32 14 10 5.5 100


10mm x 2run M210 W 11.2 60 32 14 10 9 100
12mm x 2run M212 W 13.5 60 32 14 10 11 100
6mm x 2run M206 K 7.0 70 32 20 16 5.5 50
10mm x 2run M210 K 11.2 70 32 20 16 9 50
12mm x 2run M212 K 13.7 70 32 20 16 11 50

Dimension Standard
Product
Busbar Qty.
code
A B C D E F Per Box

6mm x 3run M306 W 7.0 60 32 14 10 5.5 100


10mm x 3run M310 W 11.2 80 50 14 10 9 60
12mm x 3run M312 W 13.5 90 60 15 11 11 60
6mm x 3run M306 K 7.0 70 32 20 16 5.5 50
10mm x 3run M310 K 11.2 100 60 20 16 9 30
12mm x 3run M312 K 13.5 100 60 20 16 11 30

Dimension Standard
Product
Busbar Qty.
code
A B C D E F Per Box

6mm x 4run M406 W 7.0 80 50 14 10 5.0 60


6mm x 4run M406 K 7.0 100 60 20 16 5.0 30
10mm x 4run M410 K 11.2 130 60 20 16 9 25
12mm x 4run M412 K 13.5 130 60 20 16 11 25

Dimension Standard
Product
Busbar Qty.
code
A B C D E F Per Box

6mm x 5run M506 K 7.0 100 60 20 16 5 30


10mm x 5run M510 K 11.2 160 55 25 20 9 16
12mm x 5run M512 K 13.5 160 55 25 20 11.9 16
6mm x 6run M606 K 7.0 100 60 20 16 5 30
6mm x 8run M806 K 7.0 130 60 20 16 5 25

All Dimensions are in mm Slot Depth for busbar is 15mm Mounting Hole Dia is 8.5 mm
BUSBAR SUPPORTS & INSULATORS

MTPN Type Supports


Dimension Standard
Busabar Product
Qty.
code
A B C D N Z Y Per Box

6mmx1run/ph & 6mmx1run -N MTPN 107/30 7.2 300 280 50 7.2 65 52.5 52.5 26
10mmx1run/ph & 6mmx1run -N MTPN 111/30 11.5 300 280 50 7.2 65 52.5 52.5 26
12mmx1run/ph & 6mmx1run -N MTPN 114/30 13.7 300 280 50 7.2 65 52.5 52.5 26
6mmx1run/ph & 6mmx1run -N MTPN 107/35 7.2 350 328 50 7.2 75 62.5 62.5 16
10mmx1run/ph & 6mmx1run -N MTPN 111/35 11.5 350 328 50 7.2 75 62.5 62.5 16
12mmx1run/ph & 6mmx1run -N MTPN 114/35 13.7 350 328 50 7.2 75 62.5 62.5 16
6mmx1run/ph & 6mmx1run -N MTPN 107/42 7.2 420 396 60 7.2 100 52.5 62.5 16
10mmx1run/ph & 6mmx1run -N MTPN 111/42 11.5 420 396 60 7.2 100 52.5 62.5 16
12mmx1run/ph & 6mmx1run -N MTPN 114/42 13.7 420 396 60 7.2 100 52.5 62.5 16
MTPN-50 MTPN 50 - - - - - - - - 12

Rating Product Code Std. Qty


per box

63A /100A NL-100 20


32A NL-32 100

General Terms :
 All prices are ex-factory.
 Prices are inclusive of prevailing excise duty.
 Any other Duties & Sale Tax will be charged extra as per applicable.
 Prices are subject to revision without notice.
 All disputes are subject to Haryana Jurisdiction

Authorised Channel Partner


Adlec Power Pvt. Ltd.
Corporate Office:- Works:-
C-34/4, 2nd Floor, Lawrence Road, Delhi Rohtak Road, Decora Station Road,
Industrial Area, Delhi -110035 Behind IUP Jindal,Rohad, Distt. Jhajjar ,
PH. 45585064, 45585065, 45585066 Haryana - 124507
PH. 08607888150, 08607888111
E-mail : adlec@adlecpower.com
KUT 2.5

Approvals

General Data
Type KUT 2.5

Wire Termination Technology Screw Clamp

Ratings 800 V/24 A/2.5 sq mm/0.5 Nm

GTIN / Harmonize Custom Code 85389000

Standard Packing Qty (in No) 100

Country of Origin India

Screw Size M3

Dimensions & Weight


Height (mm) 41

Height (inches) 1.60

Width (mm) 42.50

Width (inches) 1.67 Inc

Thickness (mm) 6

Weight For Standard Packing Qty (Kg) 0.88


Material Data
Housing PA 6,6

Standard Colour Grey

Other Color Variants Black, Blue, Green, Grey, Khakhi, Red, Yellow

Rated Conductor Size


Stranded Wire - min (sq mm) 0.5

Stranded Wire - max (sq mm) 2.5

Solid Wire - min (sq mm) 0.5

Solid Wire - max (sq mm) 4

Ratings - IEC
Standard IEC 60947-7-1

Rated Voltage (V) 800

Rated Current (A) 24

Rated Cross Section (sq mm) 2.5

Short Time Withstand Current (kA) 0.48

Rated Impulse Withstand Voltage(kV) 8

Pollution Degree III

Ratings-ATEX
Certificate No 400

Rated Current (A) 20

Rated Cross Section (sq mm) 2.5

Ratings-CSA
Rated Voltage (V) 600

Rated Current (A) 25

Wire Cross Section - min (AWG) 20


Wire Cross Section - max (AWG) 12

Ratings-uL
Rated Voltage (V) 600

Rated Current (A) 25

Conductor Size - min (AWG) 20

Conductor Size - max (AWG) 12

Accessories
End Plate

KPNS

Height : 31 mm

Width : 36.50 mm

Thickness : 1.50 mm

Partition Plate Without Foot

KBM

Height : 37.50 mm

Width : 50.50 mm

Thickness : 1.50 mm

Partition Plate With Foot

KBXF

Height : 53.4 mm

Width : 54 mm

Thickness : 1.5 mm

Protection Cover
PCK3

Height : 28 mm

Width : 58.35 mm

Thickness : 1 mm

End Clamp

DCKN (Screwless - 35 mm Rail Mounted)

Height : 33 mm

Width : 43.50 mm

Thickness : 6 mm

DCKN10 (Screwless - 35 mm Rail Mounted)

Height : 33 mm

Width : 43.50 mm

Thickness : 10 mm

SCKN (35 mm Rail Mounted)

Height : 35.50 mm

Width : 50.60 mm

Thickness : 8 mm

SCUDD

Height : 50 mm

Width : 55.50 mm

Thickness : 10 mm
SCUN (Universal Rail Mounted)

Height : 35.50 mm

Width : 50.60 mm

Thickness : 9.50 mm

SCUSL

Height : 41 mm

Width : 47.50 mm

Thickness : 8 mm

Cross Connection Link Assembly

CCLK2.5

( 2W, 3W, 4W, 5W, 10W )

Comb-type Shorting Link

SLC4N

( 2 Way, 3 Way, 4 Way, 5 Way, 10 Way )

Marking Label

LABEL KN5.5
Group Marking Carrier

DCKNMLH

Height : 45.50 mm

Width : 43.50 mm

Thickness : 6 mm

SCKNMLH

Height : 45.50 mm

Width : 48 mm

Thickness : 8 mm

SCUNMLH

Height : 53.50 mm

Width : 50.60 mm

Thickness : 8 mm

Mounting Channel (Standard Lengths 300 mm, 500 mm, 1000 mm)

CHK

Height : 7.5 mm

Width : 35 mm

Thickness : 1 mm

CHKD

Height : 15 mm

Width : 35 mm

Thickness : 1.50 mm
CHKDS (Perforated)

Height : 15 mm

Width : 35 mm

Thickness : 1.50 mm

CHKS (Perforated)

Height : 7.5 mm

Width : 35 mm

Thickness : 1 mm

CHS

Height : 15 mm

Width : 32 mm

Thickness : 1.50 mm

Support for Protection Cover

UHDD

Height : 74.50 mm

Width : 55.82 mm

Thickness : 1.50 mm

Group Marking Holder

GMH 10

Height : 51 mm

Width : 41.50 mm

Thickness : 10 mm
GMH 20

Height : 51 mm

Width : 41.50 mm

Thickness : 20 mm

Window Partitions

SB1

Height : 16 mm

Width : 15.5 mm

Thickness : 0.6 mm

Note : Note : Technical specifications may change in line with technical advances and industry
standards

Note : Terminal block suitability for 1000 V rating is declared on basis of conducting dielectric
withstand voltage test as per standard IEC 60947-7-1 & IEC 60947-1.Test report can be provided
against request.

You might also like