1. Summary Coll Dimensions (mm) Cell Capacity (minimum, Ah) Voltage (nominal, V) Energy Content (nominal, Wh) Coll Weight (g) Energy Density (nominal, Whkg) Energy Density (nominal, WhiL) ‘Operating Temperature Storage Temperature Safety 38%200% 167 100 32 320 2360 140 2st 30" 61055" ¢ 40" C1060" c 1€062619; JET; UN38.3 oes Part 2.1 Capacity & Energy Test Condition: 25° C, 1.0C CC to 3.65V, 3.65V CV to 0.05C; Rest 5 min; 1.0C DC to 2.5V; Rest 5 min. ACNC Capacity Curve —Charge — Discharge (O20. 40 60 60 100) 120 Capacity(Ah) © Minimum discharge capacity is 100Ah @25° C, 1.0. © Minimum discharge energy is 320Wh @25° C, 1.0C. 2on9/n/s ACC Energy Curve _— Charge —Discharge 50 100 150 200 250 300 350 400 Energy/Wh 2.2 High & Low Temp. Capability Charge Condition: XX° C, 1C CCto 3.65V, 3.65V CV to 0.05C ischarge Condition: 1€ DC to 2.5V Discharge Capacity Rate-Voltage Discharge Capacity Rate-Temp. Rise Curve@ 36 HIL Temp. Sorc —25'¢ orc a 30 6 ze Eo a 20 ° 0% 20% 40% 60% 80% 100% 120% % Be AR Oh 80% 1K 12H Capacity Rate(%) Capacity Rato(%) eu Decne Le ucece Temp. (°C) 25 60 0 -20 -30 Capacity Retention 100% 103% 91% 78% 68% Temp. Rise(°C) 42 16 107 144 164 2197/5 2.3 Cycle Life Test Condition: 25° C& 45° C, 2.5V~3.65V(100%DOD), 1C/1C Cycle . + 25°C Cycle Life + 45°C Cycle Life ACH Cycle Curve@25°C 1C/C Cycle Curve@4s°C 105% 105% 100% Capacity retention!% 8 8 3 3 tention gg 8 eee 85% & 5% I | ort 20% ° 1000 2000 3000 4000, © 500 10001500 20002500 cycle NO, Cycle NO. @ 80% reversible capacity retention is still tested @ Prediction of cycle life @25° C is 3800cycle @ Prediction of cycle life @45° Cis 2000cycle x 3.1 Abuse Test Results Pe ee eee Ome ne -100%S0C, RT 1 Overcharge -1C charge 1h or voltage of one of cells reaches 1.5 times of charged ended voltage -100%S0C, RT; 2 Drop _-1.5 m height to concrete floor with both terminal downward, 1h observation ; a “300%806, RT -Nail diameter:5~Smm; Velocity:255mm/s, through the cell -100%S0C, RT, 4 Crush _-Crush head: 75mm, Crush to 30% displacement or OV or the crush force reaches to 200KN =100%S0C, RT 5 Hot box Heating from RT to 130:42°C atthe rate 5°C/min. Keep the temperature for 120min F Short -100%SOC, RT External resistance=50% Fire or Flame Rupture Explosion No effect ,No loss of functionality. No defect; no leakage; no venting, fire or flame; no rupture; ‘no explosion; no exothermic reaction or thermal runaway. cell reversibly damaged. Repair of protection device needed. No leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. cell irreversibly damaged. repair needed. no venting, fire, or flame; no rupture; no explosion; Weight oss<50% of electrolyte weight{electrolyte=solvent+salt) no fire or flame; no rupture; no explosion; Weight loss>=50% of electrolyte weight(electrolyte=solventssalt) no rupture; no explosion (i.e, no flying parts) no explosion, but flying parts of active mass Explosion(ie., disintegration of the cell) 100 N Ca Cpt Ut Qo ‘aaah ON _Gapechy ve. Colonie aot acs, ey re DoD e509

You might also like