1. THREE EQUIPMENT ONLY ALLOWED BY BATELEC TO ATTACHED
DIRECTLY TO THEIR POLE.
EQUIPMENTS CONSIDER ARE THE FF:
• NAP “NETWORK ACCESS POIN” (PLDT, CONVERGE)
• LCP/ CLOSURE “LOCAL CONVERGENCE POINT”/LOOP HOLDER
• TERMINAL / DP “DISTRIBUTION POINT” this 2 are for copper cable

2. ONLY 1 LOOP HOLDER ALLOWED BY MERALCO ATTACHED TO THEIR


POLE.
• POSITION OF LOOP HOLDER AND LCP/CLOSURE
Loop Holder / LCP/Closure will be installed on the level of FH messenger wire or
under Messenger wire and installed in the field position.
• MAXIMUM LOOP OF FOC “Fiber Optic Cable”
20 meters
3. FH NAP INSTALLED IN MERALCO POLE SHOULD NO MAINTENANCE
LOOP.

4. LCP/CLOSURE AND LOOP HOLDER SHOULD INSTALLED DIRECTLY TO


MERALCO POLE, BUT FOLLOW THE 3 EQUIPMENT RULES. “Note:
LCP/CLOSURE AND LOOP HOLDER COUNT AS 1 EQUIPMENT.

5. IN INSTALLATION OF MESSENGER WIRE AND FOC IT SHOULD BE


UNDER THE MERALCO TUBULAR AND PUT IT ON THE DESIGNATED RTA
POSITION.