You are on page 1of 1

1 2 3

7840 5950

300
23
C1P
C C1 C2 C3

300
3

D1
DN

11
2

300 300
E
BL UE
H CACHEQ
RD

0 4.5 .892
2
PT P
DE TH TO
0M WI AT
2.5 ENCH VER
NG
1 EIVI )

74 1751
1 LV TR CO
T. /RECL SIDE .

22
R PL
LL
FO
HING TH 0M
WA AS ITC N (M 50
R.C ENCHR. SW ATIO .+0.

C1P
ST EL )
(FFL
TR R ST
PE

CH
C

.
0M
X = 210

EN
D1

50

E TR

RD P
EL FL)
.+0.

DE UE TO
BL
(F

0 M CHEQ R AT
H CA

VE
PT

CO
1 .S
.D.S )
LV

T.
D1

WITH
PL
HV SIDE

2.5
Y=
RM . .S.T
FO 0 M
AT 0.49 (B.E
PL

RM M.
.+
EL FL)

AT 490
(F

1050
B

EL FL)
FO
PL .+0.
(F
D2

UP 0
EL. 40

MP 1:1
RO TRIC
.1

RA OPE
+7

SL
UP
EL. 098
+7.

OM
5300

EC
00
41

EL
A
DN

00
41

C1P21 60
00

9 55
00

2 .11 56 52
00 EL. 140

13
+7.

.0 EL. 049

74 748
+7.
00
41
1
B-
PD
AC

2
M)
1(E&

1
UDB-
UP
EL. 235

X = 210
PDB-
1 +7.
UP
ELDB

1
LDB-

00
UP

59
C6 9
Y UP

P1
B

300
C1

00
59
C4 C5 ENTR
Y

EL. 140
+7.
0
08
+7.
L.
L.P E

AD
RO
H
AC
P RO
AP

KEY PLAN
SCALE - 1: 1000 THIS AREA

7900
1050
NOTES :
1) ALL DIMENSIONS ARE IN MILLIMETRES & LEVELS ARE IN METRES UNO.
2) DRAWING SHALL NOT BE SCALED, ONLY WRITTEN DIMENSIONS TO
BE FOLLOWED.
3) REINFORCEMENT STEEL SHALL BE OF GRADE Fe500 TMT BARS.
4) CONCRETE USED SHALL BE M30

5) CLEAR COVER TO MAIN REINFORCEMENT SHALL BE AS FOLLOWS

A C7 C8
a) PLINTH BEAM - 50mm

350
b) FLOOR BEAM - 40mm
LAYOUT OF PLINTH BEAM c) SLAB - 30mm

@ T.O.C. EL.(+)0.450 6) EL+(0.00) CORRESPOND TO R.L.+7.2M

LEGENDS :
1) FGL FINISHED GROUND LEVEL
SCHEDULE OF PLINTH BEAMS 2) FFL FINISHED FLOOR LEVEL
3) TYP TYPICAL
EASTING NORTHING 4) TOC TOP OF CONCRETE
C1 274189.274 2101766.900 5) UNO UNLESS NOTED OTHERWISE
C2 274196.110 2101770.739
C3 274201.268 2101773.652
C4 274191.869 2101762.279
REFERENCE DRAWING:
C5 274198.705 2101766.117 1) SEWRI INTERCHANGE ARCHITECTURAL PLANS, ---- MTHL-P04-SW-01-AR-451
ELEVATIONS, & SECTIONS OF SWITCHING
C6 274203.893 2101769.031
STATION BUILDING
C7 274202.573 2101759.229
C8 274207.761 2101762.142

1 2 3
P:\984-S-MTHL -Pkg IV\4\Sewri interchange\switching station\P0\MTHL-P04-SW-01-STR-451-P0-SH.1TO 3.dwg

PB1 (300x650) PB2 (300x650)


SECTIONA-A

DESIGNER: CONTRACTOR: IDC: GC: CLIENT: PROJECT: TECHNICAL


STRUCTCON DESIGNS PVT. LTD MUMBAI TRANS HARBOUR LINK
AS SHOWN
" STRABAG AG – SISS GMBH JV”
UNIT NO. 1205,1206,1207,12TH FLOOR
‘SUPREMUS - E WING AT I THINK TITLE: SEWRI INTERCHANGE 26-09-2023
TECHNO CAMPUS,KANJURMARG
ISSUED FOR APPROVAL 26-09-2023 KSB SSK AAY ASK (EAST),MUMBAI-400 042 RCC COLUMN PLINTH BEAM LAYOUT
SIGN.: SIGN.: SIGN.: SIGN.: FOR SWITCHING STATION BUILDING P0
REV DESCRIPTION DATE DESIGNED DRAWN CHECKED APPROVED

DRAWING NO. MTHL-P04- SW-01-STR-451 1 OF 3