Contec abpm50 user manual

Contec abpm50 instructions.

User Manuals, Guides and Specifications for your Contec ABPM 50 Medical Equipment.
Database contains 1 Contec ABPM 50 Manuals (available for free online viewing or downloading in PDF): Brief instructions . Software download link: www.dlsoftw.com Index code:05RK1069 Introduction Software functionPC software is connect to the device by USB interfaceCan download NIBP measure result of the terminal deviceCan display scoop-
shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.Can edit every piece of NIBP data, and add annotation to it.Can edit basic information,doctor's advice information, NIBP status instruction, current medicine-taken information, etc.Support print preview,print the report. Introduction ABPM50 is a hand-held
ambulatory blood pressure monitor, which is designed according to oscillography theory. The device could monitor human body blood pressure up to 24 hours continuously and dynamically, providing an accurate basis for the diagnosis. It is applicable for using in hospitals, clinics and other medical institutions. Features Product features:
1) Compact and portable, user-friendly interface, easy to use 2) Patient range: adult, pediatric, neonate 3) 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be recorded for once. 4) Perfect combination of automatic and manual measurement method, up
to 300 groups of data can be recorded for once by manual measure. 5) High-definition color TFT display, strong visibility 6) By data review interface such as "data list", "trend graph", "big font", NIBP data is clear at a glance 7) Display of low power prompt, error message and time 8) Supply two
kinds of unit: mmHg / kPa 9) Display interface can be switched between Chinese and English 10) Over-limit prompt function for parameters 11) Communicate with PC, PC software can achieve data review, measured results analysis, view of trend graph, reports printing and other functions Software features:
1) Connect to the device by USB interface. 2) Download NIBP measure result from the terminal device. 3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph. 4) Edit every piece of NIBP data, and add annotation to it. 5) Edit basic information, doctor's advice, NIBP status
instruction, current medicine-taken information, etc. 6) Support report printing and print preview. Prolonged non-invasive blood pressure measurements in Auto mode may be associated with purport, ischemia and neuropathy in the limb wearing the cuff. When monitoring a patient, examine the extremities of the limb frequently for normal color,
warmth and sensitivity. If any abnormality is observed, stop the blood pressure measurements. You must not perform NIBP measurements on patients with sickle-cell disease or under any condition which the skin is damaged or expected to be damaged. For a thrombasthenia patient, it is important to determine whether measurement of the blood
pressure shall be done automatically. The determination should be based on clinical evaluation. Do not apply the cuff to a limb that has an intravenous infusion or catheter in place. This could cause tissue damage around the catheter when infusion is slowed or blocked during cuff inflation. Tips and random notes Reinstall software Follow the steps
below to remove the program prior to running the setup program again. Uninstall the ABPM50 program from "Add & Remove Program," which can be found in control panel. As an alternative, go to Start >> All Programs >> ABPM50 Monitor >> Uninstall ABPM50 Monitor to remove the program. Connect the device to the computer via the USB
port. Right click on Computer, select Manager >> Device Manager. Look for CD Class example (under Other devices) or STM32 Virtual COM port Device (under Ports). If found, double click on the entry and select Driver tab and Uninstall. Run the ABPM50_Setup. A version of the program can be found in the download section above. Install driver
(Manual) If the installed software cannot find the ABPM50, the device driver may not be installed properly. To check for this possibility, plug in the ABPM50 in the computer USB port and make sure that it is turned on. Right click on "Computer" and select "Manage" > "Device Manager". If "STM32 Virtual COM port Device (COMx)" appears (see left
diagram below) , the device driver is installed properly; if "CD Class example" appears (see right diagram below), Windows finds the device but not the driver; if no extra entry is found, Windows cannot find the device. In the third case, there is a problem with the USB connection. Try a different USB cable and/or USB port. Get another USB device to
verify that the USB cable and USB port work. In the second case, follow the following steps to reinstall the driver.

4) Perfect combination of automatic and manual measurement method, up to 300 groups of data can be recorded for once by manual measure. 5) High-definition color TFT display, strong visibility 6) By data review interface such as "data list", "trend graph", "big font", NIBP data is clear at a glance
7) Display of low power prompt, error message and time 8) Supply two kinds of unit: mmHg / kPa 9) Display interface can be switched between Chinese and English 10) Over-limit prompt function for parameters 11) Communicate with PC, PC software can achieve data review,
measured results analysis, view of trend graph, reports printing and other functions Software features: 1) Connect to the device by USB interface. 2) Download NIBP measure result from the terminal device. 3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph. 4) Edit every
piece of NIBP data, and add annotation to it. 5) Edit basic information, doctor's advice, NIBP status instruction, current medicine-taken information, etc. 6) Support report printing and print preview. Prolonged non-invasive blood pressure measurements in Auto mode may be associated with purport, ischemia and neuropathy in the limb
wearing the cuff. When monitoring a patient, examine the extremities of the limb frequently for normal color, warmth and sensitivity. If any abnormality is observed, stop the blood pressure measurements. You must not perform NIBP measurements on patients with sickle-cell disease or under any condition which the skin is damaged or expected to be
damaged.
For a thrombasthenia patient, it is important to determine whether measurement of the blood pressure shall be done automatically. The determination should be based on clinical evaluation. Do not apply the cuff to a limb that has an intravenous infusion or catheter in place. This could cause tissue damage around the catheter when infusion is slowed
or blocked during cuff inflation. Tips and random notes Reinstall software Follow the steps below to remove the program prior to running the setup program again. Uninstall the ABPM50 program from "Add & Remove Program," which can be found in control panel. As an alternative, go to Start >> All Programs >> ABPM50 Monitor >> Uninstall
ABPM50 Monitor to remove the program. Connect the device to the computer via the USB port. Right click on Computer, select Manager >> Device Manager. Look for CD Class example (under Other devices) or STM32 Virtual COM port Device (under Ports). If found, double click on the entry and select Driver tab and Uninstall. Run the
ABPM50_Setup. A version of the program can be found in the download section above. Install driver (Manual) If the installed software cannot find the ABPM50, the device driver may not be installed properly. To check for this possibility, plug in the ABPM50 in the computer USB port and make sure that it is turned on. Right click on "Computer" and
select "Manage" > "Device Manager". If "STM32 Virtual COM port Device (COMx)" appears (see left diagram below) , the device driver is installed properly; if "CD Class example" appears (see right diagram below), Windows finds the device but not the driver; if no extra entry is found, Windows cannot find the device. In the third case, there is a
problem with the USB connection. Try a different USB cable and/or USB port. Get another USB device to verify that the USB cable and USB port work. In the second case, follow the following steps to reinstall the driver. Download a new driver and save it to your hard disk. Run the exe file and extract the folder "abpm50" to a temporary location. The
folder contains two INF files, one is for 32-bit Windows and the other is for 64-bit Windows. In device manager, double click "CD Class example". Click the Driver tab, click Update Driver and follow the instructions. When Windows asks for the driver location, set it to the folder "abpm50" in the temporary location. Continue until the installation
finishes. Restart the PC. Software conflicts The programs running on your PC are interfering with each other in accessing the COM port.

3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph. 4) Edit every piece of NIBP data, and add annotation to it. 5) Edit basic information, doctor's advice, NIBP status instruction, current medicine-taken information, etc.
6) Support report printing and print preview. Prolonged non-invasive blood pressure measurements in Auto mode may be associated with purport, ischemia and neuropathy in the limb wearing the cuff. When monitoring a patient, examine the extremities of the limb frequently for normal color, warmth and sensitivity. If any abnormality is
observed, stop the blood pressure measurements. You must not perform NIBP measurements on patients with sickle-cell disease or under any condition which the skin is damaged or expected to be damaged.
For a thrombasthenia patient, it is important to determine whether measurement of the blood pressure shall be done automatically. The determination should be based on clinical evaluation. Do not apply the cuff to a limb that has an intravenous infusion or catheter in place. This could cause tissue damage around the catheter when infusion is slowed
or blocked during cuff inflation. Tips and random notes Reinstall software Follow the steps below to remove the program prior to running the setup program again. Uninstall the ABPM50 program from "Add & Remove Program," which can be found in control panel.
As an alternative, go to Start >> All Programs >> ABPM50 Monitor >> Uninstall ABPM50 Monitor to remove the program. Connect the device to the computer via the USB port. Right click on Computer, select Manager >> Device Manager. Look for CD Class example (under Other devices) or STM32 Virtual COM port Device (under Ports). If found,
double click on the entry and select Driver tab and Uninstall. Run the ABPM50_Setup. A version of the program can be found in the download section above. Install driver (Manual) If the installed software cannot find the ABPM50, the device driver may not be installed properly. To check for this possibility, plug in the ABPM50 in the computer USB
port and make sure that it is turned on. Right click on "Computer" and select "Manage" > "Device Manager". If "STM32 Virtual COM port Device (COMx)" appears (see left diagram below) , the device driver is installed properly; if "CD Class example" appears (see right diagram below), Windows finds the device but not the driver; if no extra entry is
found, Windows cannot find the device. In the third case, there is a problem with the USB connection. Try a different USB cable and/or USB port.
Features Product features: 1) Compact and portable, user-friendly interface, easy to use 2) Patient range: adult, pediatric, neonate 3) 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be recorded for once. 4) Perfect combination of automatic and manual
measurement method, up to 300 groups of data can be recorded for once by manual measure. 5) High-definition color TFT display, strong visibility 6) By data review interface such as "data list", "trend graph", "big font", NIBP data is clear at a glance 7) Display of low power prompt, error message and time
8) Supply two kinds of unit: mmHg / kPa 9) Display interface can be switched between Chinese and English 10) Over-limit prompt function for parameters 11) Communicate with PC, PC software can achieve data review, measured results analysis, view of trend graph, reports printing and other
functions Software features: 1) Connect to the device by USB interface. 2) Download NIBP measure result from the terminal device. 3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph. 4) Edit every piece of NIBP data, and add annotation to it.
5) Edit basic information, doctor's advice, NIBP status instruction, current medicine-taken information, etc. 6) Support report printing and print preview.

It is applicable for using in hospitals, clinics and other medical institutions. Features Product features: 1) Compact and portable, user-friendly interface, easy to use 2) Patient range: adult, pediatric, neonate 3) 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be
recorded for once. 4) Perfect combination of automatic and manual measurement method, up to 300 groups of data can be recorded for once by manual measure. 5) High-definition color TFT display, strong visibility 6) By data review interface such as "data list", "trend graph", "big font", NIBP data is clear at a
glance 7) Display of low power prompt, error message and time 8) Supply two kinds of unit: mmHg / kPa 9) Display interface can be switched between Chinese and English 10) Over-limit prompt function for parameters 11) Communicate with PC, PC software can achieve data review,
measured results analysis, view of trend graph, reports printing and other functions Software features: 1) Connect to the device by USB interface. 2) Download NIBP measure result from the terminal device. 3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph. 4) Edit every
piece of NIBP data, and add annotation to it. 5) Edit basic information, doctor's advice, NIBP status instruction, current medicine-taken information, etc. 6) Support report printing and print preview. Prolonged non-invasive blood pressure measurements in Auto mode may be associated with purport, ischemia and neuropathy in the limb
wearing the cuff. When monitoring a patient, examine the extremities of the limb frequently for normal color, warmth and sensitivity. If any abnormality is observed, stop the blood pressure measurements. You must not perform NIBP measurements on patients with sickle-cell disease or under any condition which the skin is damaged or expected to be
damaged. For a thrombasthenia patient, it is important to determine whether measurement of the blood pressure shall be done automatically. The determination should be based on clinical evaluation. Do not apply the cuff to a limb that has an intravenous infusion or catheter in place. This could cause tissue damage around the catheter when infusion
is slowed or blocked during cuff inflation. Tips and random notes Reinstall software Follow the steps below to remove the program prior to running the setup program again. Uninstall the ABPM50 program from "Add & Remove Program," which can be found in control panel. As an alternative, go to Start >> All Programs >> ABPM50 Monitor >>
Uninstall ABPM50 Monitor to remove the program. Connect the device to the computer via the USB port. Right click on Computer, select Manager >> Device Manager. Look for CD Class example (under Other devices) or STM32 Virtual COM port Device (under Ports). If found, double click on the entry and select Driver tab and Uninstall. Run the
ABPM50_Setup. A version of the program can be found in the download section above. Install driver (Manual) If the installed software cannot find the ABPM50, the device driver may not be installed properly. To check for this possibility, plug in the ABPM50 in the computer USB port and make sure that it is turned on. Right click on "Computer" and
select "Manage" > "Device Manager". If "STM32 Virtual COM port Device (COMx)" appears (see left diagram below) , the device driver is installed properly; if "CD Class example" appears (see right diagram below), Windows finds the device but not the driver; if no extra entry is found, Windows cannot find the device. In the third case, there is a
problem with the USB connection. Try a different USB cable and/or USB port. Get another USB device to verify that the USB cable and USB port work. In the second case, follow the following steps to reinstall the driver. Download a new driver and save it to your hard disk. Run the exe file and extract the folder "abpm50" to a temporary location. The
folder contains two INF files, one is for 32-bit Windows and the other is for 64-bit Windows. In device manager, double click "CD Class example". Click the Driver tab, click Update Driver and follow the instructions.

Introduction ABPM50 is a hand-held ambulatory blood pressure monitor, which is designed according to oscillography theory. The device could monitor human body blood pressure up to 24 hours continuously and dynamically, providing an accurate basis for the diagnosis.
It is applicable for using in hospitals, clinics and other medical institutions. Features Product features: 1) Compact and portable, user-friendly interface, easy to use 2) Patient range: adult, pediatric, neonate 3) 24 hours ambulatory NIBP monitoring function, up to 350 groups of ambulatory NIBP data can be
recorded for once. 4) Perfect combination of automatic and manual measurement method, up to 300 groups of data can be recorded for once by manual measure. 5) High-definition color TFT display, strong visibility 6) By data review interface such as "data list", "trend graph", "big font", NIBP data is clear at a
glance 7) Display of low power prompt, error message and time 8) Supply two kinds of unit: mmHg / kPa 9) Display interface can be switched between Chinese and English 10) Over-limit prompt function for parameters 11) Communicate with PC, PC software can achieve data review,
measured results analysis, view of trend graph, reports printing and other functions Software features: 1) Connect to the device by USB interface. 2) Download NIBP measure result from the terminal device. 3) Display of scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph.
4) Edit every piece of NIBP data, and add annotation to it.
5) Edit basic information, doctor's advice, NIBP status instruction, current medicine-taken information, etc. 6) Support report printing and print preview. Prolonged non-invasive blood pressure measurements in Auto mode may be associated with purport, ischemia and neuropathy in the limb wearing the cuff.
When monitoring a patient, examine the extremities of the limb frequently for normal color, warmth and sensitivity. If any abnormality is observed, stop the blood pressure measurements.
You must not perform NIBP measurements on patients with sickle-cell disease or under any condition which the skin is damaged or expected to be damaged. For a thrombasthenia patient, it is important to determine whether measurement of the blood pressure shall be done automatically. The determination should be based on clinical evaluation.
Do not apply the cuff to a limb that has an intravenous infusion or catheter in place. This could cause tissue damage around the catheter when infusion is slowed or blocked during cuff inflation. Tips and random notes Reinstall software Follow the steps below to remove the program prior to running the setup program again. Uninstall the ABPM50
program from "Add & Remove Program," which can be found in control panel. As an alternative, go to Start >> All Programs >> ABPM50 Monitor >> Uninstall ABPM50 Monitor to remove the program. Connect the device to the computer via the USB port. Right click on Computer, select Manager >> Device Manager. Look for CD Class example
(under Other devices) or STM32 Virtual COM port Device (under Ports). If found, double click on the entry and select Driver tab and Uninstall. Run the ABPM50_Setup. A version of the program can be found in the download section above. Install driver (Manual) If the installed software cannot find the ABPM50, the device driver may not be installed
properly. To check for this possibility, plug in the ABPM50 in the computer USB port and make sure that it is turned on. Right click on "Computer" and select "Manage" > "Device Manager". If "STM32 Virtual COM port Device (COMx)" appears (see left diagram below) , the device driver is installed properly; if "CD Class example" appears (see right
diagram below), Windows finds the device but not the driver; if no extra entry is found, Windows cannot find the device. In the third case, there is a problem with the USB connection. Try a different USB cable and/or USB port. Get another USB device to verify that the USB cable and USB port work.
In the second case, follow the following steps to reinstall the driver. Download a new driver and save it to your hard disk. Run the exe file and extract the folder "abpm50" to a temporary location.
The folder contains two INF files, one is for 32-bit Windows and the other is for 64-bit Windows. In device manager, double click "CD Class example". Click the Driver tab, click Update Driver and follow the instructions. When Windows asks for the driver location, set it to the folder "abpm50" in the temporary location. Continue until the installation
finishes. Restart the PC. Software conflicts The programs running on your PC are interfering with each other in accessing the COM port. One fix is to remove the offending program; however this works only if you know this is the problem and the trick is to find out the offending programs. I am not aware of any easy way to determine the conflict.
There are a few things you can do to look for hints. Communication error messages (e.g. "Read COM failed") when running a program. This program is a partner involved in the conflict. Error messages during system or program startup. The program generating the error message is another potential candidate. Install the software on another PC
(preferably a clean PC without installed programs that uses the USB port).
For one particular case, on a computer we used for testing various devices, we finally decided to reinstall Windows to solve the problem. Possible fixes for resolving software conflicts are: Uninstall the offending program. Reinstall Windows Multi-boot: By installing multiple operating systems on the same computer, you can built a "clean" one and run
the software on this copy. The drawback is you would require extra disk space and at least two disk partitions, one for each copy. Virtual machine: See Microsoft Windows virtual PC, VMware virtual machine and Windows XP virtual machine. Each virtual machine would run within its own environment and would eliminate any interference. When
building a virtual machine, do not copy from one that contains the conflicting software. The application does not use a lot of resources. Any old computer running WXP would work. If you encounter any software conflict, just re-install Windows to get a clean machine. You should try to install the software on another computer first to verify the problem
before trying multi-boot or virtual machine. These two approaches, though not difficult, require some expertise in installing Windows. There are many other advantages in running multiple instances of Windows on one computer, which has saved us many times in the past. Cuff sizes The width of the cuff should be either 40% of the limb circumference
(50% for neonates) or 2/3 of the upper arm length. The inflatable part of the cuff should be long enough to encircle 50-80%of the limb. The wrong size of cuff can cause erroneous readings. If the cuff size is in question, then use a larger cuff. Make sure that the cuff edge falls within the range of mark <->. If it does not, use a larger or smaller cuff that
fits better. PatientLimb PerimeterCuff Width Infant10-19 cm8 cm Child18-26 cm10.6 cm Adult125-35 cm14 cm Adult233 - 47 cm17 cm Thigh46-66 cm21 cm ABPM CPT procedure codes CPT code 93784 thru 93790 may be used for billing purposes, including: DescriptionCPT Ambulatory blood pressure monitoring; including recording, scanning
analysis, interpretation and report.93784 Recording only93786 Scanning analysis with report93788 Physician review with interpretation and report93790 ABPM related IDC-9 codes ConditionIDC-9 Elevated blood pressure reading without diagnosis of hypertension (The only ICD-9 code covered by Medicare)796.2 Essential hypertension401 Essential
hypertension - Unspecified (Resistant)401.9 Hypertensive heart disease402 Hypertensive renal disease403 Nocturnal angina413.0 Ill-defined descriptions and complications of heart disease429 Orthostatic hypotension458 Hypotension, unspecified458.9 Hypertension complicating pregnancy, childbirth, and the puerperium642 Transient hypertension
of pregnancy642.2 Mild or unspecified pre-eclampsia642.4 Unspecified hypertension complicating pregnancy642.9 Maternal hypotension syndrome669.2 Syncope and collapse780.2 Other Hypertension (Episodic, Labile, Postural)997.91 Medicare has approved the use of ABPM under certain medical situations. Useful information on ambulatory blood
pressure monitor Ambulatory blood pressure monitoring, Barry P McGrath, and on behalf of the National Blood Pressure Advisory Committee of the National Heart Foundation of Australia, The Medical Journal of Australia Ambulatory blood pressure, Wikipedia Clinical applications of ambulatory blood pressure monitor, Michael E. Ernst, PharMD,
BCPS, George R. Bergus, MD, Medscape Today

You might also like