You are on page 1of 4

Firefox https://cstools.asme.org/Interpretation/InterpretationDetail.

cfm

Interpretation Detail
Standa BPV Section VIII Div 1
rd
Design
ation:

Edition
/Adden
da:

Para./F
ig.
/Table
No:

Subject Section VIII-1, Table UNF-23.2, Material Properties of


Descrip SB-75 Seamless Copper Tubes
tion:

Date 10/01/1984
Issued:

Record BC83-538
Numbe
r:

Interpr VIII-1-83-304
etation
Numbe
r:

Questio
n(s) Question: May the ends of SB-75 annealed
and copper tubes to be contained wholly in the
Reply(i expanded depth of tubesheet holes be
es): annealed to a yield strength below the
speci�ed minimum of 9.0 ksi as given in
Table UNF-23.2 of Section VIII, Division 1, if
the tubes are to be joined to the tubesheet
by expanding?

Reply: Yes.

1 di 4 13/03/2024, 14:05
Firefox https://cstools.asme.org/Interpretation/InterpretationDetail.cfm

Print to PDF

Standa BPV Section VIII Div 1


rd
Design
ation:

Edition
/Adden
da:

Para./F
ig.
/Table
No:

Subject Section VIII, Division 1, SB-111, Copper Alloy 706


Descrip
tion:

Date 01/18/1977
Issued:

Record NA
Numbe
r:

Interpr VIII-77-06
etation
Numbe
r:

Questio
n(s) Questions: Is light drawn tubing in
and accordance with SB-111, Alloy 706
Reply(i acceptable for Section VIII, Division 1
es): vessels? Are there problems in recognizing
hard drawn tubing?

Replies: SB-111, Alloy 706, light drawn


tubing is acceptable in Table UNF-23.2 of
Section VIII, Division 1. The Summer 1976
Addenda should have re�ected this in the
tabulation; however, this will be corrected in
the Winter 1976 Addenda in the Errata
portion. With regard to hard drawn tubing,
the Committee has not received a user
request for this material and, therefore, has
not addressed its inclusion in Section VIII,
Division 1.

2 di 4 13/03/2024, 14:05
Firefox https://cstools.asme.org/Interpretation/InterpretationDetail.cfm

Print to PDF

Standa BPV Section VIII Div 1


rd
Design
ation:

Edition
/Adden
da:

Para./F
ig.
/Table
No:

Subject Section VIII - Division 1, Maximum Allowable External


Descrip Working Pressure for Seamless Copper Alloy Tubes
tion:

Date 04/17/1980
Issued:

Record BC-79-763
Numbe
r:

Interpr VIII-80-27
etation
Numbe
r:

Questio
n(s) Question: Is it permissible to establish the
and maximum allowable external working
Reply(i pressure of seamless copper tubes
es): complying with SB-111 Alloy 19200 by the
formula in Code Case 1847?

Reply: No. Code Case 1847 is for special


tubes with integral �ns. Maximum allowable
external working pressure for all other tubes
shall be established using the rules of
UG-28.