100% found this document useful (3 votes)
11K views18 pages

Alcon IOL Catalog

The document is a product catalogue for IOLs (intraocular lenses). It includes sections on toric IOLs, multifocal IOLs, IOL accessories, and IOL delivery systems. The toric IOLs section provides details on the AcrySof IQ Toric lens models, including optic type, size, dioptric range, delivery system compatibility, and recommended cartridges.

Uploaded by

Meiliaty Angky
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
11K views18 pages

Alcon IOL Catalog

The document is a product catalogue for IOLs (intraocular lenses). It includes sections on toric IOLs, multifocal IOLs, IOL accessories, and IOL delivery systems. The toric IOLs section provides details on the AcrySof IQ Toric lens models, including optic type, size, dioptric range, delivery system compatibility, and recommended cartridges.

Uploaded by

Meiliaty Angky
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • IOL Product Catalogue Cover: The cover of the IOL Product Catalogue introducing Advanced Technologies and Cataract lenses.
  • Advanced Technologies: Overview of the advanced technologies in intraocular lenses, focusing on Toric, Multifocal IOLs, and their accessories.
  • Cataract: Details advancements in cataract solutions focusing on Monofocal IOLs technologies and models.

IOL Product Catalogue

ADVANCED CATARACT
TECHNOLOGIES
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES

I OLs

TOR IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

IOLs

Toric IOLs

Multifocal IOLs

IOL accessories

IOL Delivery Systems

Pictograms legend
Type of use

2 Disposable 2 Reusable

2
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®

OPTIC LENGTH HAPTIC DIOPTRIC


MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT2 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT3 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT4 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 2.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT5 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT6 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.75 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT7 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 4.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT8 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 5.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT9 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 6.00 D Cylinder
Aspheric
Haptics
2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


*Available in 0.5 D increments. **Available in 1.0 D increments.† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS MULTIFOCAL IOLs MONOFOCAL IOLs

3
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®

OPTIC LENGTH HAPTIC DIOPTRIC


MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Biconvex UV only filter +6.0 - +30.0 D*


SA6AT2 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 1.00 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT3 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 1.50 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT4 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 2.25 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT5 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 3.00 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT6 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 3.75 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT7 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 4.50 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT8 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 5.25 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT9 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 6.00 D Cylinder
2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


*Available in 0.5 D increments. **Available in 1.0 D increments.† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS MULTIFOCAL IOLs MONOFOCAL IOLs

4
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

TFNT00

AcrySof® IQ PanOptix® IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV filter


STABLEFORCE® Haptics +6.0 - +30.0 D
Diffractive +2.17 D intermediate and (0.5 D incr.)
TFNT00 6.0 13.0 0º 119.1† MONARCH® III 2 2
Aspheric +3.25 D near add power +31.0 - +34.0 D
Featuring ENLIGHTEN (1.0 D incr.) 2 2
technology

† Suggested a-constant for optical ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

5
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

TFNT20/ TFNT30/ TFNT40/ TFNT50/ TFNT60

AcrySof® IQ PanOptix® Toric IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT20 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.00 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT30 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.50 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT40 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
2.25 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT50 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.00 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT60 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.75 D Cylinder 2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

6
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

SN6AD1/ SV25T0/ SN6AD3 MN6AD1

AcrySof® IQ ReSTOR® IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD1 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+3.0 D add power
(1.0 D incr.) 2 2

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SV25T0 Diffractive 6.0 13.0 0º STABLEFORCE® 119.1† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+2.5 D add power
(1.0 D incr.) 2 2

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD3 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+4.0 D add power
(1.0 D incr.) 2 2

+6.0 - +30.0 D
Apodized Blue Light +
(0.5 D incr.)
UV filter MONARCH® III
MN6AD1 Diffractive 6.0 13.0 0º 119.2† 2 2
+31.0 - +34.0 D MONARCH® II
Aspheric +3.0 D add power
(1.0 D incr.) 2 2

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

7
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ ReSTOR® Toric +3.0

AcrySof® IQ ReSTOR® Toric +3.0 IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T2 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 1.00 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T3 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 1.50 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T4 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 2.25 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T5 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 3.00 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T6 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 3.75 D Cylinder 2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

8
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ ReSTOR® Toric +2.5

AcrySof® IQ ReSTOR® Toric +2.5 IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
Diffractive
SV25T2 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 1.00 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T3 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 1.50 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T4 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 2.25 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T5 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 3.00 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T6 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 3.75 D Cylinder

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

9
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES Multifocal and Toric IOLs
TO R IC IO Ls
MONARCH® Cartridge Model/Diopter Range
M U LTIF O CA L IO Ls
Cartridge1 Cartridge2 Cartridge2
MN6AD1 6.0-34.0 D SN6AT2 6.0-30.0 D TFNT00 6.0-30.0 SN6AT2 6.0-27.0 D
I O L A CCES S O R IES 2 2 2 2 2 2 D TFNT00 6.0-27.0 D
SN6AT3 6.0-30.0 D TFNT20 6.0-30.0 D SN6AT3 6.0-25.0 D TFNT20 6.0-27.0 D
Cartridge2 SN6AT4 6.0-30.0 D SN6AT4 6.0-25.0 D
TFNT30 6.0-30.0 D TFNT30 6.0-25.0 D
I O L D EL I V ERY S Y S TEM S SN6AT2 6.0-34.0 D TFNT00 6.0-34.0 D SN6AT5 6.0-30.0 D TFNT40 6.0-30.0 D SN6AT5 6.0-25.0 D TFNT40 6.0-25.0 D
2 2
SN6AT3 6.0-34.0 D TFNT20 6.0-34.0 D SN6AT6 6.0-27.0 D TFNT50 6.0-30.0 D SN6AT6 6.0-23.0 D TFNT50 6.0-25.0 D
SN6AT4 6.0-34.0 D TFNT30 6.0-34.0 D SN6AT7 6.0-27.0 D TFNT60 6.0-30.0 D SN6AT7 6.0-23.0 D TFNT60 6.0-25.0 D
SN6AT5 6.0-34.0 D TFNT40 6.0-34.0 D SN6AT8 6.0-27.0 D SN6AD1 6.0-27.0 D SN6AT8 6.0-23.0 D SN6AD1 6.0-27.0 D
SN6AT6 6.0-34.0 D TFNT50 6.0-34.0 D SN6AT9 6.0-27.0 D SN6AD3 6.0-27.0 D SN6AT9 6.0-23.0 D SN6AD3 6.0-27.0 D
SN6AT7 6.0-34.0 D TFNT60 6.0-34.0 D SA6AT2 6.0-30.0 D SND1T2 6.0-30.0 D SA6AT2 6.0-27.0 D SND1T2 6.0-25.0 D
SN6AT8 6.0-34.0 D SN6AD3 6.0-34.0 D SA6AT3 6.0-30.0 D SND1T3 6.0-30.0 D SA6AT3 6.0-25.0 D SND1T3 6.0-25.0 D
SN6AT9 6.0-34.0 D SN6AD1 6.0-34.0 D SA6AT4 6.0-30.0 D SND1T4 6.0-30.0 D SA6AT4 6.0-25.0 D SND1T4 6.0-25.0 D
SA6AT2 6.0-34.0 D SND1T2 6.0-30.0 D SA6AT5 6.0-30.0 D SND1T5 6.0-30.0 D SA6AT5 6.0-25.0 D SND1T5 6.0-25.0 D
SA6AT3 6.0-34.0 D SND1T3 6.0-30.0 D SA6AT6 6.0-27.0 D SND1T6 6.0-30.0 D SA6AT6 6.0-23.0 D SND1T6 6.0-25.0 D
SA6AT4 6.0-34.0 D SND1T4 6.0-30.0 D SA6AT7 6.0-27.0 D SV25T0 6.0-30.0 D SA6AT7 6.0-23.0 D SV25T0 6.0-27.0 D
SA6AT5 6.0-34.0 D SND1T5 6.0-30.0 D SA6AT8 6.0-27.0 D SV25T2 6.0-30.0 D SA6AT8 6.0-23.0 D SV25T2 6.0-25.0 D
SA6AT6 6.0-34.0 D SND1T6 6.0-30.0 D SN6AT9 6.0-27.0 D SV25T3 6.0-30.0 D SA6AT9 6.0-23.0 D SV25T3 6.0-25.0 D
SA6AT7 6.0-34.0 D SV25T0 6.0-34.0 D SV25T4 6.0-30.0 D SV25T4 6.0-25.0 D
SA6AT8 6.0-34.0 D MA60AC 6.0-34.0 D SV25T5 6.0-30.0 D SV25T5 6.0-25.0 D
SA6AT9 6.0-34.0 D MN60AC 6.0-34.0 D SV25T6 6.0-30.0 D
MN6AD1 6.0-34.0 D

IOL Delivery Systems


Cartridges

8065977757 MONARCH® A Cartridges - 2 2


2 2
8065977758 MONARCH® B Cartridges - 2 2
2 2
8065977762 MONARCH® C Cartridges - 2 2
2 2
8065977763 MONARCH® D Cartridges - 2 2
2 2

2 2 2 2 2 2 2 2
Injectors

8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2 2

8065977771 MONARCH® II IOL Injector Green (use with A/B/C Cartridges) 2 2

B C D

A B C

Handpiece

8065-751755 INTREPID® AUTOSERT® Handpiece 2 2

1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.

MULTIFOCAL IOLs TORIC IOLs MONOFOCAL IOLs IOL ACCESSORIES

10
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT

M O N O F O C A L I O Ls

Monofocal
IOLs

AcrySof® IQ

Clareon® AutonoMe®

AcrySof® Single-Piece

AcrySof® Multipiece

Single-Piece PMMA

IOL Delivery Systems

Pictograms legend
Type of use
2 Disposable 2 Reusable

11
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof IQ ® Advan
CATARACT SUR
ASPHERIC IOL
M O N O F O C A L I O Ls

AU00T0 /ACU00T0

SN60WF SA60WF

AcrySof® IQ IOLs
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV +6.0 - +30.0 D


Aspheric filter (0.5 D incr.)
SN60WF Asymmetric 6.0 13.0 0º 118.7† MONARCH® III C D 2
Biconvex STABLEFORCE® +30.0 - +40.0 D
Haptics (1 D incr.)
UV filter +6.0 - +30.0 D
Aspheric
(0.5 D incr.)
SA60WF Asymmetric 6.0 13.0 0º STABLEFORCE® 118.7† MONARCH® III C D 2
Biconvex Haptics +30.0 - +40.0 D
(1 D incr.)
Blue Light + UV
Aspheric filter +6.0 - +27.0 D* Pre-Loaded
AU00T0 Asymmetric 6.0 13.0 0º 27.5 - +30D** 118.7† UltraSert IQ 2
UltraSert ®
STABLEFORCE ®
Biconvex (0.5 D incr.) BLF+UV only
Haptics

Aspheric UV filter +6.0 - +27.0 D* Pre-Loaded


ACU00T0 Asymmetric 6.0 13.0 0º STABLEFORCE® 27.5 - +30D** 118.7† UltraSert 2
UltraSert®
Biconvex Haptics (0.5 D incr.) UV only

Blue Light + UV
Aspheric filter
SN6CWS Asymmetric +6.0 - +30.0 D Pre-Loaded
6.0 13.0 0º 118.7† 2
AcrySert®
STABLEFORCE® (0.5 D incr.) AcrySert®
Biconvex
Haptics

*16.0 to +27.0 D D-Nozzle. **27.5 to+30D C-Nozzle. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

12
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls

CNA0T0

Clareon® AutonoMe®
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV
Aspheric filter +6.0 - +30.0 D Pre-Loaded
CNA0T0 Asymmetric 6.0 13.0 0º 119.1 2
STABLEFORCE® (0.5 D incr.) AutonoMe®
Biconvex
Haptics

Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

13
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®

M O N O F O C A L I O Ls

SN60AT SA60AT

AcrySof® Single-piece IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

+6.0 - +30.0 D
Anterior (0,5 D incr.)
Blue Light + UV
SN60AT Asymmetric 6.0 13.0 0º 118.4† MONARCH® III B C 2
filter +31.0 - +40.0
Biconvex
D (1.0 D incr.)
+6.0 - +30.0 D
Anterior (0,5 D incr.)
SA60AT Asymmetric 6.0 13.0 0º UV only filter 118.4† MONARCH® III B C 2
Biconvex +31.0 - +40.0
D (1.0 D incr.)

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

14
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®

M O N O F O C A L I O Ls

MN60AC MA60AC

AcrySof® Multipiece IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Anterior
Blue Light + UV +6.0 - +30.0 D
MN60AC Asymmetric 6.0 13.0 10º 118.4† MONARCH® II A 2
filter (0.5 D incr.)
Biconvex

Anterior
+6.0 - +30.0 D
MA60AC Asymmetric 6.0 13.0 10º UV only filter 118.4† MONARCH® II A 2
(0.5 D incr.)
Biconvex

AcrySof® Multipiece - Posterior Convex IOL


+6.0 - +30 .0 D
MA50BM Biconvex 6.5 13.0 10º UV only filter 118.9† MONARCH® II A 2
(0.5 D incr.)

AcrySof® Multipiece - Expand® Series IOL


Blue Light + UV -5.0 - +5.0 D
MN60MA Meniscus 6.0 13.0 5º 118.9† MONARCH® II A 2
only filter (1.0 D incr.)

-5.0 - +5.0 D
MA60MA Meniscus 6.0 13.0 5º UV only filter 118.9† MONARCH® II A 2
(1.0 D incr.)

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

15
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs PMMA
M O N O F O C A L I O Ls

CZ70BD MTA3U0
MTA4U0
MTA5U0

Single-piece PMMA IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY
SIZE RANGE/
NUMBER TYPE (mm) ANGULATION FEATURES A-CONSTANT SYSTEM
(mm) INCREMENTS

+10.0 - +30.0 D Implanting


CZ70BD Biconvex 7.0 12.5 5° SLANT™ UV only filter 118.8† 2
(0.5 D incr.) Forceps

Single-piece PMMA Anterior Chamber IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC SUGGESTED DELIVERY
SIZE RANGE/ ACD1
NUMBER TYPE (mm) ANGULATION A-CONSTANT SYSTEM
(mm) INCREMENTS

+5.0 - +30.0 D Implanting


MTA3U0 Convexoplano 5.5 12.5 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

+5.0 - +30.0 D Implanting


MTA4U0 Convexoplano 5.5 13.0 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

+5.0 - +30.0 D Implanting


MTA5U0 Convexoplano 5.5 13.5 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

1. ACD is based on the Birkhorst relationship as presented in Holladay, J.T., Musgrove, K.H., Prager, T.C., Lewis, J.W., Chandler, T.Y., and Ruiz, R.S., “A three-part system for refining
intraocular lens power calculations,” Journal of Cataract and Refractive Surgery, Vol. 14, pp. 17-24, 1988. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

16
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls
MONARCH® Cartridge Model/Diopter Range

A Cartridge1 B Cartridge2 C Cartridge2 D Cartridge2


MA50BM 6.0-30.0 D SN60WF 6.0-30.0 D SN60WF 6.0-30.0 D SN60WF 6.0-27.0 D
MA60AC 6.0-30.0 D SA60WF 6.0-30.0 D SA60WF 6.0-30.0 D SA60WF 6.0-27.0 D
MN60AC -5.0-5.0 D SN60AT 6.0-40.0 D SN60AT 6.0-27.0 D
MN60MA -5.0-5.0 D SA60AT 6.0-40.0 D SA60AT 6.0-27.0 D

IOL Delivery Systems


Cartridges

8065977757 MONARCH® A Cartridges - A 2

8065977758 MONARCH® B Cartridges - B 2

8065977762 MONARCH® C Cartridges - C 2

8065977763 MONARCH® D Cartridges - D 2

A B C D

Injectors

8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2

8065977771 MONARCH® II IOL Injector Green (use with A/B/C Cartridges) 2

B C D

A B C

1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.

MONOFOCAL IOLs MULTIFOCAL IOLs TORIC IOLs

17
AcrySof IQ PanOptix Toric
® ® Advancing
CATARACT SURGERY
P RES BY O P I A -C O RRE C T I N G I OL

AcrySof IQ ® Advancing
CATARACT SURGERY
ASPHERIC IOL

© 2019 Alcon 11/18 ACR-18-MK-CAT-001-EU

You might also like