You are on page 1of 18

IOL Product Catalogue

ADVANCED CATARACT
TECHNOLOGIES
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES

I OLs

TOR IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

IOLs

Toric IOLs

Multifocal IOLs

IOL accessories

IOL Delivery Systems

Pictograms legend
Type of use

2 Disposable 2 Reusable

2
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®

OPTIC LENGTH HAPTIC DIOPTRIC


MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT2 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT3 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT4 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 2.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT5 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT6 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.75 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT7 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 4.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT8 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 5.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT9 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 6.00 D Cylinder
Aspheric
Haptics
2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


*Available in 0.5 D increments. **Available in 1.0 D increments.† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS MULTIFOCAL IOLs MONOFOCAL IOLs

3
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®

OPTIC LENGTH HAPTIC DIOPTRIC


MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Biconvex UV only filter +6.0 - +30.0 D*


SA6AT2 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 1.00 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT3 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 1.50 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT4 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 2.25 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT5 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 3.00 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT6 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 3.75 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT7 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 4.50 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT8 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 5.25 D Cylinder
2 2
Biconvex UV only filter +6.0 - +30.0 D*
SA6AT9 Toric 6.0 13.0 0º STABLEFORCE® +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
Aspheric Haptics 6.00 D Cylinder
2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


*Available in 0.5 D increments. **Available in 1.0 D increments.† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS MULTIFOCAL IOLs MONOFOCAL IOLs

4
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

TFNT00

AcrySof® IQ PanOptix® IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV filter


STABLEFORCE® Haptics +6.0 - +30.0 D
Diffractive +2.17 D intermediate and (0.5 D incr.)
TFNT00 6.0 13.0 0º 119.1† MONARCH® III 2 2
Aspheric +3.25 D near add power +31.0 - +34.0 D
Featuring ENLIGHTEN (1.0 D incr.) 2 2
technology

† Suggested a-constant for optical ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

5
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

TFNT20/ TFNT30/ TFNT40/ TFNT50/ TFNT60

AcrySof® IQ PanOptix® Toric IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT20 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.00 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT30 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.50 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT40 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
2.25 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT50 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.00 D Cylinder 2 2

+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT60 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.75 D Cylinder 2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

6
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

SN6AD1/ SV25T0/ SN6AD3 MN6AD1

AcrySof® IQ ReSTOR® IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD1 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+3.0 D add power
(1.0 D incr.) 2 2

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SV25T0 Diffractive 6.0 13.0 0º STABLEFORCE® 119.1† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+2.5 D add power
(1.0 D incr.) 2 2

Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD3 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+4.0 D add power
(1.0 D incr.) 2 2

+6.0 - +30.0 D
Apodized Blue Light +
(0.5 D incr.)
UV filter MONARCH® III
MN6AD1 Diffractive 6.0 13.0 0º 119.2† 2 2
+31.0 - +34.0 D MONARCH® II
Aspheric +3.0 D add power
(1.0 D incr.) 2 2

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

7
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ ReSTOR® Toric +3.0

AcrySof® IQ ReSTOR® Toric +3.0 IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T2 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 1.00 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T3 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 1.50 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T4 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 2.25 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T5 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 3.00 D Cylinder 2 2

Biconvex Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
SND1T6 Diffractive 6.0 13.0 0º STABLEFORCE® Spherical 118.9† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric +3.0 D add power 3.75 D Cylinder 2 2

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

8
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls

M U LTIF O CA L IO Ls

I O L A CCES S O R IES

I O L D EL I V ERY S Y S TEM S

AcrySof® IQ ReSTOR® Toric +2.5

AcrySof® IQ ReSTOR® Toric +2.5 IOLs


OPTIC LENGTH HAPTIC DIOPTRIC
MODEL OPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + +6.0 - +30.0 D


Apodized UV filter (0.5 D incr.)
Diffractive
SV25T2 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 1.00 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T3 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 1.50 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T4 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 2.25 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T5 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 3.00 D Cylinder
Blue Light + +6.0 - +30.0 D
Apodized UV filter (0.5 D incr.)
Diffractive
SV25T6 6.0 13.0 0º STABLEFORCE® Spherical 119.1† MONARCH® III 2 2
Aspheric Haptics Equivalent
Toric 2 2
+2.5 D add power 3.75 D Cylinder

AcrySof® Toric Calculator: http://www.acrysoftoriccalculator.com/


† Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

DELIVERY SYSTEMS TORIC IOLs MONOFOCAL IOLs

9
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES Multifocal and Toric IOLs
TO R IC IO Ls
MONARCH® Cartridge Model/Diopter Range
M U LTIF O CA L IO Ls
Cartridge1 Cartridge2 Cartridge2
MN6AD1 6.0-34.0 D SN6AT2 6.0-30.0 D TFNT00 6.0-30.0 SN6AT2 6.0-27.0 D
I O L A CCES S O R IES 2 2 2 2 2 2 D TFNT00 6.0-27.0 D
SN6AT3 6.0-30.0 D TFNT20 6.0-30.0 D SN6AT3 6.0-25.0 D TFNT20 6.0-27.0 D
Cartridge2 SN6AT4 6.0-30.0 D SN6AT4 6.0-25.0 D
TFNT30 6.0-30.0 D TFNT30 6.0-25.0 D
I O L D EL I V ERY S Y S TEM S SN6AT2 6.0-34.0 D TFNT00 6.0-34.0 D SN6AT5 6.0-30.0 D TFNT40 6.0-30.0 D SN6AT5 6.0-25.0 D TFNT40 6.0-25.0 D
2 2
SN6AT3 6.0-34.0 D TFNT20 6.0-34.0 D SN6AT6 6.0-27.0 D TFNT50 6.0-30.0 D SN6AT6 6.0-23.0 D TFNT50 6.0-25.0 D
SN6AT4 6.0-34.0 D TFNT30 6.0-34.0 D SN6AT7 6.0-27.0 D TFNT60 6.0-30.0 D SN6AT7 6.0-23.0 D TFNT60 6.0-25.0 D
SN6AT5 6.0-34.0 D TFNT40 6.0-34.0 D SN6AT8 6.0-27.0 D SN6AD1 6.0-27.0 D SN6AT8 6.0-23.0 D SN6AD1 6.0-27.0 D
SN6AT6 6.0-34.0 D TFNT50 6.0-34.0 D SN6AT9 6.0-27.0 D SN6AD3 6.0-27.0 D SN6AT9 6.0-23.0 D SN6AD3 6.0-27.0 D
SN6AT7 6.0-34.0 D TFNT60 6.0-34.0 D SA6AT2 6.0-30.0 D SND1T2 6.0-30.0 D SA6AT2 6.0-27.0 D SND1T2 6.0-25.0 D
SN6AT8 6.0-34.0 D SN6AD3 6.0-34.0 D SA6AT3 6.0-30.0 D SND1T3 6.0-30.0 D SA6AT3 6.0-25.0 D SND1T3 6.0-25.0 D
SN6AT9 6.0-34.0 D SN6AD1 6.0-34.0 D SA6AT4 6.0-30.0 D SND1T4 6.0-30.0 D SA6AT4 6.0-25.0 D SND1T4 6.0-25.0 D
SA6AT2 6.0-34.0 D SND1T2 6.0-30.0 D SA6AT5 6.0-30.0 D SND1T5 6.0-30.0 D SA6AT5 6.0-25.0 D SND1T5 6.0-25.0 D
SA6AT3 6.0-34.0 D SND1T3 6.0-30.0 D SA6AT6 6.0-27.0 D SND1T6 6.0-30.0 D SA6AT6 6.0-23.0 D SND1T6 6.0-25.0 D
SA6AT4 6.0-34.0 D SND1T4 6.0-30.0 D SA6AT7 6.0-27.0 D SV25T0 6.0-30.0 D SA6AT7 6.0-23.0 D SV25T0 6.0-27.0 D
SA6AT5 6.0-34.0 D SND1T5 6.0-30.0 D SA6AT8 6.0-27.0 D SV25T2 6.0-30.0 D SA6AT8 6.0-23.0 D SV25T2 6.0-25.0 D
SA6AT6 6.0-34.0 D SND1T6 6.0-30.0 D SN6AT9 6.0-27.0 D SV25T3 6.0-30.0 D SA6AT9 6.0-23.0 D SV25T3 6.0-25.0 D
SA6AT7 6.0-34.0 D SV25T0 6.0-34.0 D SV25T4 6.0-30.0 D SV25T4 6.0-25.0 D
SA6AT8 6.0-34.0 D MA60AC 6.0-34.0 D SV25T5 6.0-30.0 D SV25T5 6.0-25.0 D
SA6AT9 6.0-34.0 D MN60AC 6.0-34.0 D SV25T6 6.0-30.0 D
MN6AD1 6.0-34.0 D

IOL Delivery Systems


Cartridges

8065977757 MONARCH® A Cartridges - 2 2


2 2
8065977758 MONARCH® B Cartridges - 2 2
2 2
8065977762 MONARCH® C Cartridges - 2 2
2 2
8065977763 MONARCH® D Cartridges - 2 2
2 2

2 2 2 2 2 2 2 2
Injectors

8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2 2

8065977771 MONARCH® II IOL Injector Green (use with A/B/C Cartridges) 2 2

B C D

A B C

Handpiece

8065-751755 INTREPID® AUTOSERT® Handpiece 2 2

1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.

MULTIFOCAL IOLs TORIC IOLs MONOFOCAL IOLs IOL ACCESSORIES

10
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT

M O N O F O C A L I O Ls

Monofocal
IOLs

AcrySof® IQ

Clareon® AutonoMe®

AcrySof® Single-Piece

AcrySof® Multipiece

Single-Piece PMMA

IOL Delivery Systems

Pictograms legend
Type of use
2 Disposable 2 Reusable

11
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof IQ ® Advan
CATARACT SUR
ASPHERIC IOL
M O N O F O C A L I O Ls

AU00T0 /ACU00T0

SN60WF SA60WF

AcrySof® IQ IOLs
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV +6.0 - +30.0 D


Aspheric filter (0.5 D incr.)
SN60WF Asymmetric 6.0 13.0 0º 118.7† MONARCH® III C D 2
Biconvex STABLEFORCE® +30.0 - +40.0 D
Haptics (1 D incr.)
UV filter +6.0 - +30.0 D
Aspheric
(0.5 D incr.)
SA60WF Asymmetric 6.0 13.0 0º STABLEFORCE® 118.7† MONARCH® III C D 2
Biconvex Haptics +30.0 - +40.0 D
(1 D incr.)
Blue Light + UV
Aspheric filter +6.0 - +27.0 D* Pre-Loaded
AU00T0 Asymmetric 6.0 13.0 0º 27.5 - +30D** 118.7† UltraSert IQ 2
UltraSert ®
STABLEFORCE ®
Biconvex (0.5 D incr.) BLF+UV only
Haptics

Aspheric UV filter +6.0 - +27.0 D* Pre-Loaded


ACU00T0 Asymmetric 6.0 13.0 0º STABLEFORCE® 27.5 - +30D** 118.7† UltraSert 2
UltraSert®
Biconvex Haptics (0.5 D incr.) UV only

Blue Light + UV
Aspheric filter
SN6CWS Asymmetric +6.0 - +30.0 D Pre-Loaded
6.0 13.0 0º 118.7† 2
AcrySert®
STABLEFORCE® (0.5 D incr.) AcrySert®
Biconvex
Haptics

*16.0 to +27.0 D D-Nozzle. **27.5 to+30D C-Nozzle. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

12
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls

CNA0T0

Clareon® AutonoMe®
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

Blue Light + UV
Aspheric filter +6.0 - +30.0 D Pre-Loaded
CNA0T0 Asymmetric 6.0 13.0 0º 119.1 2
STABLEFORCE® (0.5 D incr.) AutonoMe®
Biconvex
Haptics

Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

13
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®

M O N O F O C A L I O Ls

SN60AT SA60AT

AcrySof® Single-piece IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS

+6.0 - +30.0 D
Anterior (0,5 D incr.)
Blue Light + UV
SN60AT Asymmetric 6.0 13.0 0º 118.4† MONARCH® III B C 2
filter +31.0 - +40.0
Biconvex
D (1.0 D incr.)
+6.0 - +30.0 D
Anterior (0,5 D incr.)
SA60AT Asymmetric 6.0 13.0 0º UV only filter 118.4† MONARCH® III B C 2
Biconvex +31.0 - +40.0
D (1.0 D incr.)

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

14
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®

M O N O F O C A L I O Ls

MN60AC MA60AC

AcrySof® Multipiece IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES INCREMENTS A-CONSTANT SYSTEM CARTRIDGES
(mm)

Anterior
Blue Light + UV +6.0 - +30.0 D
MN60AC Asymmetric 6.0 13.0 10º 118.4† MONARCH® II A 2
filter (0.5 D incr.)
Biconvex

Anterior
+6.0 - +30.0 D
MA60AC Asymmetric 6.0 13.0 10º UV only filter 118.4† MONARCH® II A 2
(0.5 D incr.)
Biconvex

AcrySof® Multipiece - Posterior Convex IOL


+6.0 - +30 .0 D
MA50BM Biconvex 6.5 13.0 10º UV only filter 118.9† MONARCH® II A 2
(0.5 D incr.)

AcrySof® Multipiece - Expand® Series IOL


Blue Light + UV -5.0 - +5.0 D
MN60MA Meniscus 6.0 13.0 5º 118.9† MONARCH® II A 2
only filter (1.0 D incr.)

-5.0 - +5.0 D
MA60MA Meniscus 6.0 13.0 5º UV only filter 118.9† MONARCH® II A 2
(1.0 D incr.)

† Suggested a-constant for immersion ultrasound biometry.


Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

15
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs PMMA
M O N O F O C A L I O Ls

CZ70BD MTA3U0
MTA4U0
MTA5U0

Single-piece PMMA IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY
SIZE RANGE/
NUMBER TYPE (mm) ANGULATION FEATURES A-CONSTANT SYSTEM
(mm) INCREMENTS

+10.0 - +30.0 D Implanting


CZ70BD Biconvex 7.0 12.5 5° SLANT™ UV only filter 118.8† 2
(0.5 D incr.) Forceps

Single-piece PMMA Anterior Chamber IOLs


OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC SUGGESTED DELIVERY
SIZE RANGE/ ACD1
NUMBER TYPE (mm) ANGULATION A-CONSTANT SYSTEM
(mm) INCREMENTS

+5.0 - +30.0 D Implanting


MTA3U0 Convexoplano 5.5 12.5 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

+5.0 - +30.0 D Implanting


MTA4U0 Convexoplano 5.5 13.0 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

+5.0 - +30.0 D Implanting


MTA5U0 Convexoplano 5.5 13.5 0.5 3.39 115.3† 2
(0.5 D incr.) Forceps

1. ACD is based on the Birkhorst relationship as presented in Holladay, J.T., Musgrove, K.H., Prager, T.C., Lewis, J.W., Chandler, T.Y., and Ruiz, R.S., “A three-part system for refining
intraocular lens power calculations,” Journal of Cataract and Refractive Surgery, Vol. 14, pp. 17-24, 1988. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.

NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS

16
ADVANCED CATARACT
TECHNOLOGIES

THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls
MONARCH® Cartridge Model/Diopter Range

A Cartridge1 B Cartridge2 C Cartridge2 D Cartridge2


MA50BM 6.0-30.0 D SN60WF 6.0-30.0 D SN60WF 6.0-30.0 D SN60WF 6.0-27.0 D
MA60AC 6.0-30.0 D SA60WF 6.0-30.0 D SA60WF 6.0-30.0 D SA60WF 6.0-27.0 D
MN60AC -5.0-5.0 D SN60AT 6.0-40.0 D SN60AT 6.0-27.0 D
MN60MA -5.0-5.0 D SA60AT 6.0-40.0 D SA60AT 6.0-27.0 D

IOL Delivery Systems


Cartridges

8065977757 MONARCH® A Cartridges - A 2

8065977758 MONARCH® B Cartridges - B 2

8065977762 MONARCH® C Cartridges - C 2

8065977763 MONARCH® D Cartridges - D 2

A B C D

Injectors

8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2

8065977771 MONARCH® II IOL Injector Green (use with A/B/C Cartridges) 2

B C D

A B C

1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.

MONOFOCAL IOLs MULTIFOCAL IOLs TORIC IOLs

17
AcrySof IQ PanOptix Toric
® ® Advancing
CATARACT SURGERY
P RES BY O P I A -C O RRE C T I N G I OL

AcrySof IQ ® Advancing
CATARACT SURGERY
ASPHERIC IOL

© 2019 Alcon 11/18 ACR-18-MK-CAT-001-EU

You might also like