Professional Documents
Culture Documents
ADVANCED CATARACT
TECHNOLOGIES
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
I OLs
TOR IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
IOLs
Toric IOLs
Multifocal IOLs
IOL accessories
Pictograms legend
Type of use
2 Disposable 2 Reusable
2
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT2 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT3 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 1.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT4 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 2.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT5 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.00 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT6 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 3.75 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT7 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 4.50 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT8 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 5.25 D Cylinder
Aspheric
Haptics
2 2
Blue Light +
Biconvex UV filter +6.0 - +30.0 D*
SN6AT9 Toric 6.0 13.0 0º +31.0 - +34.0 D** 119.0† MONARCH® III 2 2
STABLEFORCE® 6.00 D Cylinder
Aspheric
Haptics
2 2
3
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Toric IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
AcrySof® IQ Toric
AcrySof IQ Toric IOLs
®
4
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
TFNT00
5
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT20 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.00 D Cylinder 2 2
+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT30 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
1.50 D Cylinder 2 2
+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT40 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
2.25 D Cylinder 2 2
+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT50 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.00 D Cylinder 2 2
+6.0 - +30.0 D
Blue Light + UV filter (0.5 D incr.)
Diffractive STABLEFORCE® Haptics
TFNT60 6.0 13.0 0º +31.0 - +34.0 D 119.1† MONARCH® III 2 2
Aspheric +2.17 D intermediate and
+3.25 D near add power
(1.0 D incr.)
3.75 D Cylinder 2 2
6
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD1 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+3.0 D add power
(1.0 D incr.) 2 2
Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SV25T0 Diffractive 6.0 13.0 0º STABLEFORCE® 119.1† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+2.5 D add power
(1.0 D incr.) 2 2
Blue Light +
UV filter
+6.0 - +30.0 D
Apodized (0.5 D incr.)
SN6AD3 Diffractive 6.0 13.0 0º STABLEFORCE® 118.9† MONARCH® III 2 2
Aspheric Haptics +31.0 - +34.0 D
+4.0 D add power
(1.0 D incr.) 2 2
+6.0 - +30.0 D
Apodized Blue Light +
(0.5 D incr.)
UV filter MONARCH® III
MN6AD1 Diffractive 6.0 13.0 0º 119.2† 2 2
+31.0 - +34.0 D MONARCH® II
Aspheric +3.0 D add power
(1.0 D incr.) 2 2
7
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
8
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES
Multifocal IOLs
TO R IC IO Ls
M U LTIF O CA L IO Ls
I O L A CCES S O R IES
I O L D EL I V ERY S Y S TEM S
9
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
ADVANCED
TECHNOLOGIES Multifocal and Toric IOLs
TO R IC IO Ls
MONARCH® Cartridge Model/Diopter Range
M U LTIF O CA L IO Ls
Cartridge1 Cartridge2 Cartridge2
MN6AD1 6.0-34.0 D SN6AT2 6.0-30.0 D TFNT00 6.0-30.0 SN6AT2 6.0-27.0 D
I O L A CCES S O R IES 2 2 2 2 2 2 D TFNT00 6.0-27.0 D
SN6AT3 6.0-30.0 D TFNT20 6.0-30.0 D SN6AT3 6.0-25.0 D TFNT20 6.0-27.0 D
Cartridge2 SN6AT4 6.0-30.0 D SN6AT4 6.0-25.0 D
TFNT30 6.0-30.0 D TFNT30 6.0-25.0 D
I O L D EL I V ERY S Y S TEM S SN6AT2 6.0-34.0 D TFNT00 6.0-34.0 D SN6AT5 6.0-30.0 D TFNT40 6.0-30.0 D SN6AT5 6.0-25.0 D TFNT40 6.0-25.0 D
2 2
SN6AT3 6.0-34.0 D TFNT20 6.0-34.0 D SN6AT6 6.0-27.0 D TFNT50 6.0-30.0 D SN6AT6 6.0-23.0 D TFNT50 6.0-25.0 D
SN6AT4 6.0-34.0 D TFNT30 6.0-34.0 D SN6AT7 6.0-27.0 D TFNT60 6.0-30.0 D SN6AT7 6.0-23.0 D TFNT60 6.0-25.0 D
SN6AT5 6.0-34.0 D TFNT40 6.0-34.0 D SN6AT8 6.0-27.0 D SN6AD1 6.0-27.0 D SN6AT8 6.0-23.0 D SN6AD1 6.0-27.0 D
SN6AT6 6.0-34.0 D TFNT50 6.0-34.0 D SN6AT9 6.0-27.0 D SN6AD3 6.0-27.0 D SN6AT9 6.0-23.0 D SN6AD3 6.0-27.0 D
SN6AT7 6.0-34.0 D TFNT60 6.0-34.0 D SA6AT2 6.0-30.0 D SND1T2 6.0-30.0 D SA6AT2 6.0-27.0 D SND1T2 6.0-25.0 D
SN6AT8 6.0-34.0 D SN6AD3 6.0-34.0 D SA6AT3 6.0-30.0 D SND1T3 6.0-30.0 D SA6AT3 6.0-25.0 D SND1T3 6.0-25.0 D
SN6AT9 6.0-34.0 D SN6AD1 6.0-34.0 D SA6AT4 6.0-30.0 D SND1T4 6.0-30.0 D SA6AT4 6.0-25.0 D SND1T4 6.0-25.0 D
SA6AT2 6.0-34.0 D SND1T2 6.0-30.0 D SA6AT5 6.0-30.0 D SND1T5 6.0-30.0 D SA6AT5 6.0-25.0 D SND1T5 6.0-25.0 D
SA6AT3 6.0-34.0 D SND1T3 6.0-30.0 D SA6AT6 6.0-27.0 D SND1T6 6.0-30.0 D SA6AT6 6.0-23.0 D SND1T6 6.0-25.0 D
SA6AT4 6.0-34.0 D SND1T4 6.0-30.0 D SA6AT7 6.0-27.0 D SV25T0 6.0-30.0 D SA6AT7 6.0-23.0 D SV25T0 6.0-27.0 D
SA6AT5 6.0-34.0 D SND1T5 6.0-30.0 D SA6AT8 6.0-27.0 D SV25T2 6.0-30.0 D SA6AT8 6.0-23.0 D SV25T2 6.0-25.0 D
SA6AT6 6.0-34.0 D SND1T6 6.0-30.0 D SN6AT9 6.0-27.0 D SV25T3 6.0-30.0 D SA6AT9 6.0-23.0 D SV25T3 6.0-25.0 D
SA6AT7 6.0-34.0 D SV25T0 6.0-34.0 D SV25T4 6.0-30.0 D SV25T4 6.0-25.0 D
SA6AT8 6.0-34.0 D MA60AC 6.0-34.0 D SV25T5 6.0-30.0 D SV25T5 6.0-25.0 D
SA6AT9 6.0-34.0 D MN60AC 6.0-34.0 D SV25T6 6.0-30.0 D
MN6AD1 6.0-34.0 D
2 2 2 2 2 2 2 2
Injectors
8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2 2
B C D
A B C
Handpiece
1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.
10
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
M O N O F O C A L I O Ls
Monofocal
IOLs
AcrySof® IQ
Clareon® AutonoMe®
AcrySof® Single-Piece
AcrySof® Multipiece
Single-Piece PMMA
Pictograms legend
Type of use
2 Disposable 2 Reusable
11
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof IQ ® Advan
CATARACT SUR
ASPHERIC IOL
M O N O F O C A L I O Ls
AU00T0 /ACU00T0
SN60WF SA60WF
AcrySof® IQ IOLs
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS
Blue Light + UV
Aspheric filter
SN6CWS Asymmetric +6.0 - +30.0 D Pre-Loaded
6.0 13.0 0º 118.7† 2
AcrySert®
STABLEFORCE® (0.5 D incr.) AcrySert®
Biconvex
Haptics
*16.0 to +27.0 D D-Nozzle. **27.5 to+30D C-Nozzle. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.
NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS
12
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls
CNA0T0
Clareon® AutonoMe®
OPTIC DIOPTRIC
MODEL OPTIC LENGTH HAPTIC OTHER SUGGESTED DELIVERY RECOMMENDED
SIZE RANGE/
NUMBER TYPE (mm) ANG. FEATURES A-CONSTANT SYSTEM CARTRIDGES
(mm) INCREMENTS
Blue Light + UV
Aspheric filter +6.0 - +30.0 D Pre-Loaded
CNA0T0 Asymmetric 6.0 13.0 0º 119.1 2
STABLEFORCE® (0.5 D incr.) AutonoMe®
Biconvex
Haptics
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.
NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS
13
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®
M O N O F O C A L I O Ls
SN60AT SA60AT
+6.0 - +30.0 D
Anterior (0,5 D incr.)
Blue Light + UV
SN60AT Asymmetric 6.0 13.0 0º 118.4† MONARCH® III B C 2
filter +31.0 - +40.0
Biconvex
D (1.0 D incr.)
+6.0 - +30.0 D
Anterior (0,5 D incr.)
SA60AT Asymmetric 6.0 13.0 0º UV only filter 118.4† MONARCH® III B C 2
Biconvex +31.0 - +40.0
D (1.0 D incr.)
NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS
14
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs AcrySof ®
M O N O F O C A L I O Ls
MN60AC MA60AC
Anterior
Blue Light + UV +6.0 - +30.0 D
MN60AC Asymmetric 6.0 13.0 10º 118.4† MONARCH® II A 2
filter (0.5 D incr.)
Biconvex
Anterior
+6.0 - +30.0 D
MA60AC Asymmetric 6.0 13.0 10º UV only filter 118.4† MONARCH® II A 2
(0.5 D incr.)
Biconvex
-5.0 - +5.0 D
MA60MA Meniscus 6.0 13.0 5º UV only filter 118.9† MONARCH® II A 2
(1.0 D incr.)
NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS
15
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs PMMA
M O N O F O C A L I O Ls
CZ70BD MTA3U0
MTA4U0
MTA5U0
1. ACD is based on the Birkhorst relationship as presented in Holladay, J.T., Musgrove, K.H., Prager, T.C., Lewis, J.W., Chandler, T.Y., and Ruiz, R.S., “A three-part system for refining
intraocular lens power calculations,” Journal of Cataract and Refractive Surgery, Vol. 14, pp. 17-24, 1988. † Suggested a-constant for immersion ultrasound biometry.
Additional information on IOL constants obtained using ZEISS IOLMASTER‡ may be found at www.augenklinik.uni-wuerzburg.de/eulib/const.htm. This site is not maintained by
Alcon and is for reference only. Availability varies by market. Provided as a guideline only. +2.5 D A-Constant measured with optical coherence, +3.0 D A-Constant measured
through immersion. ‡IOLMASTER is a trademark of Carl Zeiss AG.
NON PRE-LOADED
MULTIFOCAL IOLs TORIC IOLs
DELIVERY SYSTEMS
16
ADVANCED CATARACT
TECHNOLOGIES
THERAPEUTIC AREA
CATARACT
Monofocal IOLs
M O N O F O C A L I O Ls
MONARCH® Cartridge Model/Diopter Range
A B C D
Injectors
8065977773 MONARCH® III IOL Injector Blue (use with B/C/D Cartridges) 2
B C D
A B C
1. Validated with the MONARCH® II IOL Delivery System. 2. Validated with the MONARCH® III IOL Delivery System.
17
AcrySof IQ PanOptix Toric
® ® Advancing
CATARACT SURGERY
P RES BY O P I A -C O RRE C T I N G I OL
AcrySof IQ ® Advancing
CATARACT SURGERY
ASPHERIC IOL