You are on page 1of 3
3119724, 254 PM. Engine Crank But not starting / No Active code Communication History Staff Account (Simon Emerson) via channel ‘Email’ 19-03-2024 09:46 Hello Vinu, Based on your evidence, | suggest replacing Spark plug 3. If the issue is still ongoing, can you please follow the instructions in Service Manual 9000SRM1112 - DIAGNOSTIC TROUBLESHOOTING MANUAL. SECTION 9020 ENGINE > Group 30 Observed Symptoms > Engine Does Not Start/Engine is Hard to Start: A. FUEL TANK IS EMPTY. B. FAULTY CABLE CONNECTIONS. C. BATTERY STATE (DISCHARGED OR FAULTY). D. IGNITION SYSTEM PROBLEM (GASOLINE AND LPG ENGINES). E. GLOW PLUG PROBLEMS (KUBOTA 3.6L AND YANMAR DIESEL ENGINES ONLY). F. FUEL SYSTEM PROBLEM G. ENGINE SENSOR PROBLEM. H. ENGINE MECHANICAL PROBLEMS. |. INTAKE OR EXHAUST SYSTEM IS TOO RESTRICTIVE J. ENGINE OIL PROBLEMS K, LOW FUEL INDICATOR ILLUMINATED (LPG FUEL SYSTEM ONLY) Kind regards, Simon ‘ntps:ihyster-eu custhelp convappiaccountiquestionsidetal_|dl4837764 18 3119724, 254 PM Engine Crank But not starting / No Active code Customer (Vinu-H Puthan Malika) via channel ‘CSS Web’ 18-03-2024 14:28 Dear sir, ‘As during troubleshoot found no electrical connector for ignitor Please update is this machine model have that connection Waiting for your support and assistance machine down from more the 2 weeks Customer (Vinu-H Puthan Malika) via channel ‘CSS Web’ 16-03-2024 17:38 Dear Sir, As per the machine details Engine crank but not starting checked LPG line found LPG flow normal upto inlet . No active code occure during cranking . checked spark plug found spark not coming , Checked igniter coil resistence as per check steps in manual found with in specification. . done all possible checked as per attached file found normal except spark plug wire resistance spark plug wire resistance found in Kilo ohms as per bellow 1.) 8.4 kohms ; 2.) 11.2 Kohms ; 3.) OL; 4.) 16.2 Kohms Please advise us if we can change/replace the spark plug wire the above issue will solve? Additional Details Email Address vinu.malika@kanoo.com Reference Number 240316-000011 Status Waiting for Dealer Created 16-03-2024 17:38 Updated 19-03-2024 09:46 Product + Hyster Support Category + Service * Trucks + Engine / Fuel System / Exhaust File Attachments + SPARK PLUG WIRES CHECK.png (79.79 KB) ‘ntps:ihyster-eu custhelp convappiaccountiquestionsidetal_|dl4837764 218 119124, 2:54 PM Engine Crank But not starting / No Active code * Screenshot 2024-03-15 174322.png (155.23 KB) IT Incident Source Ask a Question Unit SIN L177810981D Truck Model H3.0FT Hourmeter (H/M) 11926 Status /Error Code CRANK BUT NOT STARTING / NO ACTIVE CODE Truck Application Construction Truck Down Yes Tech on Site Yes cc jayakumar j@kanoo.com;shubham.pandey@kaanoo.com;balraj.bawa@kanoo, comijagtar.singh@kanoo.com hitpssnyster-eu.custhelp.com/appfaccountquestionsdtali_ol4837764 a3

You might also like