You are on page 1of 5

■ MEMBER NAME : B3 [ Section : BOTH END ]

1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm

2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 217MPa

3. Section
(1) Section Size : 250 x 350mm ( R-Section )
(2) Cover : 40.00mm
(3) Compression : Considered
(4) Splicing Limit : 50%

250
40

350
40

4. Moments and Forces


(1) : 51.89kN·m
(2) : 13.16kN·m
(3) : 56.81kN

http://www.midasuser.com
1/5
5. Reinforcement
(1) Top Bar = 804mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(2) Bot Bar = 402mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(3) Stirrup = 157mm² )

6. Check Bending Moment Capacity ( Positive )


(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ = =
ㆍ = = 455mm, =2
ㆍ s = 134 < 455mm → O.K
(3) Calculate required ratio of reinforcement
ㆍ = =
ㆍ = = 0.0051
ㆍ = = 0.0034
ㆍ = = 0.0034
ㆍ Checked by doubly rebar
ㆍ = 0.0236
ㆍ = 0.0110
ㆍ = = 0.0347
(4) Check ratio of tensile reinforcement
ㆍ ρ = = 0.0055

(5) Calculate moment capacity
ㆍ a = 42.36mm
ㆍ ø = 0.900
ㆍ = 32.87kN·m
ㆍ = 29.58kN·m
(6) Calculate ratio of moment capacity
ㆍ = 0.445 → O.K

7. Check Bending Moment Capacity ( Negative )


(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ = =
ㆍ = = 455mm, =2
ㆍ s = 44.67 < 455mm → O.K
(3) Calculate required ratio of reinforcement
ㆍ = =
ㆍ = = 0.0051
ㆍ = = 0.0143
ㆍ = = 0.0051
ㆍ Checked by doubly rebar
ㆍ = 0.0236
ㆍ = 0.0055
ㆍ = = 0.0292
(4) Check ratio of tensile reinforcement
ㆍ ρ = = 0.0110

(5) Calculate moment capacity
ㆍ a = 49.20mm
ㆍ ø = 0.900
ㆍ = 59.17kN·m
ㆍ = 53.25kN·m
(6) Calculate ratio of moment capacity
ㆍ = 0.974 → O.K

http://www.midasuser.com
2/5
8. Check Shear Capacity
(1) Calculate shear strength by concrete
ㆍ ø = 0.750 d = 292mm
ㆍ = = 42.65kN

(2) Calculate required shear strength by shear reinforcement
ㆍ = = 18.88kN
ㆍ = = 110kN Refer to [ 11.4.5.3 ]
ㆍ = = 221kN

ㆍ = =
ㆍ = = 0.403mm²/mm
ㆍ = = 0.298mm²/mm
ㆍ = = 0.403mm²/mm
(3) Calculate shear strength by stirrup
ㆍ =2 = 78.50mm² ( d10 )
ㆍ = = 149kN
(4) Calculate ratio of shear capacity
ㆍ = = 192kN
ㆍ = 0.296 → O.K
(5) Calculate spacing limits for reinforcement
ㆍ = min [ d/2, 600mm ] = 146mm
ㆍ = = 389mm
ㆍ = = 146mm
ㆍ s = = 146mm → O.K

■ MEMBER NAME : B3 [ Section : MIDDLE ]

1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm

2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 217MPa

3. Section
(1) Section Size : 250 x 350mm ( R-Section )
(2) Cover : 40.00mm
(3) Compression : Considered
(4) Splicing Limit : 50%

http://www.midasuser.com
3/5
40 250

350
40

4. Moments and Forces


(1) : 9.220kN·m
(2) : 28.07kN·m
(3) : 13.65kN

5. Reinforcement
(1) Top Bar = 402mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(2) Bot Bar = 603mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(3) Stirrup = 157mm² )

http://www.midasuser.com
4/5
6. Check Bending Moment Capacity ( Positive )
(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ = =
ㆍ = = 455mm, =2
ㆍ s = 67.00 < 455mm → O.K
(3) Calculate required ratio of reinforcement
ㆍ = =
ㆍ = = 0.0051
ㆍ = = 0.0074
ㆍ = = 0.0051
ㆍ Checked by doubly rebar
ㆍ = 0.0236
ㆍ = 0.0055
ㆍ = = 0.0292
(4) Check ratio of tensile reinforcement
ㆍ ρ = = 0.0083

(5) Calculate moment capacity
ㆍ a = 43.75mm
ㆍ ø = 0.900
ㆍ = 45.92kN·m
ㆍ = 41.33kN·m
(6) Calculate ratio of moment capacity
ㆍ = 0.679 → O.K

7. Check Bending Moment Capacity ( Negative )


(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ = =
ㆍ = = 455mm, =2
ㆍ s = 134 < 455mm → O.K
(3) Calculate required ratio of reinforcement
ㆍ = =
ㆍ = = 0.0051
ㆍ = = 0.0024
ㆍ = = 0.0024
ㆍ Checked by doubly rebar
ㆍ = 0.0236
ㆍ = 0.0083
ㆍ = = 0.0319
(4) Check ratio of tensile reinforcement
ㆍ ρ = = 0.0055

(5) Calculate moment capacity
ㆍ a = 41.02mm
ㆍ ø = 0.900
ㆍ = 32.77kN·m
ㆍ = 29.49kN·m
(6) Calculate ratio of moment capacity
ㆍ = 0.313 → O.K

8. Check Shear Capacity


(1) Calculate shear strength by concrete
ㆍ ø = 0.750 d = 292mm
ㆍ = = 42.65kN

(2) Calculate shear strength by stirrup
ㆍ =2 = 78.50mm² ( d10 )
ㆍ = = 74.61kN
(3) Calculate ratio of shear capacity
ㆍ = = 117kN
ㆍ = 0.116 → O.K
(4) Calculate spacing limits for reinforcement
ㆍ = min [ d/2, 600mm ] = 146mm
ㆍ = = 146mm
ㆍ = = 146mm
ㆍ s = = 146mm → O.K

http://www.midasuser.com
5/5