You are on page 1of 17

LogTag® Recorders

What's new in LogTag® Analyzer 3.1


Tuesday, March 3, 2020 - relates to LogTag® Analyzer Version 3.1r9

We are pleased to announce the latest update for LogTag® Analyzer, now released as version 3.1.
This update supports new products, but also contains bug fixes and has some new features as well
as improved functionality. It introduces dew point calculations for humidity loggers and a new,
simplified wireless connection wizard.

We have compiled this information sheet for those who have already used earlier versions and
wish to familiarize themselves with the new functionality of version 3.1.

Please also refer to the LogTag® Analyzer User Guide, which can be found in the HELP menu of
the LogTag® Analyzer software. Both User Guide and Help File are continually updated so you can
access concise and accurate information about our products.

LogTag® Online
LogTag® Online (LTO) is a Cloud-based, real-time online monitoring system providing alarm
notifications, compliance, record storage and reporting functions.

LTO allows its users to download data from LogTag® data loggers, view the data in the cloud, and
allows the sharing and securing of the data based on users' permissions.

LogTag® Analyzer offers several integration features with LogTag® Online, allowing you to upload
data from loggers via your desktop interface cradle.

The LogTag® Analyzer User Guide details these integration features, particularly the connection to
LogTag® Drive, one of the features of LogTag® Online. You will learn how to:

l Sign in and out of your LogTag® Online account directly from Analyzer
l Upload files directly to the LogTag® Online Drive from Analyzer
l Upload data to LogTag® Online locations
l Opening files stored in the LogTag® Online Drive from Analyzer
l Working with multiple LogTag® Online Teams

Please refer to the section Integrating LogTag® Analyzer with LogTag® Online in the
LogTag®Analyzer User Guide or to the LogTag® website at logtagrecorders.com/online.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 1 of 17
Support for new Models in Revision 3.1r9
Version 3.1r9 adds support for a new multi-use USB PDF temperature logger with display and
external sensor, the UTRED-16.

UTRED-16
Multi-use USB PDF Temperature Logger with
Display and external sensor

Support for new Models in Revision 3.1r7


Version 3.1r7 adds support for a new single use logger, the USRID-16.

USRID-16
Single use USB PDF Temperature Logger with
Display

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 2 of 17
Support for new Models in Revision 3.1r6
UHADO-16 HASO-8
USB PDF Temperature and Single use Temperature and
Humidity Logger with Display Humidity Logger

Support for new Models in revision 3.1r5


UTRED30-16 UTRED30-Wifi TREL30-16
USB PDF 30-day Logger USB PDF 30-day Wireless Logger Low Temperature Logger
with Display with Display with Display

For more detailed information please refer to the User Guides for each specific product, available
from the LogTag® Recorders website at logtagrecorders.com/products.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 3 of 17
Addition of French, Japanese, Portuguese and
Simplified Chinese
We are delighted to announce that French, Japanese, Portuguese and Simplified Chinese have been
added to the list of display languages for LogTag® Analyzer version 3.1. This brings the list of fully
supported languages to 8:

l English
l French (introduced in version 3.1r5)
l German
l Japanese (introduced in version 3.1r7)
l Russian
l Portuguese (introduced in version 3.1r9)
l Simplified Chinese (introduced in version 3.1r7)
l Spanish

We would not be able to offer these translations without the help of our distributors, so a big thank
you to all involved for making this possible.

We will endeavor to support more languages in the near future.

Resettable Min/Max Display


(supported in version 3.1r5)

LogTag® Analyzer Version 3.1 adds support for a new feature, which has been introduced in to a
number of products, such as the TRED30-16R, TREL30-16, UTRED30-16 and UTRED30-Wifi. It will
allow these models to show trip minimum/maximum temperatures, which the user can reset while
the unit is still logging.

During configuration, you can enable this new feature for TRED30-16R and TREL30-16 loggers by
selecting Show user resettable Min/Max in the Advanced logger options. If enabled, two additional
screens are shown when reviewing the statistics on the device display, which contain the minimum
and maximum temperature values recorded since the device was started. These values can be
cleared on the device, and new Min/Max temperatures will be recorded from the time the values
were cleared.

UTRED30-16 and UTRED30-Wifi automatically display these values on the display during logging;
for these two products you can Allow a user to reset trip Min/Max values in the Advanced logger
options.

For more detailed information how the values are displayed and how you can clear them please
refer to the User Guides of the respective products, available from the LogTag® Recorders website
at https://logtagrecorders.com/products.

If the option is not presented in the Advanced Options Dialogue, the product does not
support this feature.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 4 of 17
Multi Chart Data Tab
(introduced in 3.1r5)

Data listings are now available when viewing a multi chart. Here, the data listings for the
individual loggers are combined into a single list, with each row representing one reading from a
single logger.

Marks, text and background colors are shown in the same way as for single file lists.

Readings are initially sorted and indexed chronologically, but can be sorted by clicking one of the
column headers. This can be useful, for example, when you want to look at all readings from a
specific logger. If you wish to return to the original chronological sort order, simply click the Index
column header.

You can add a comment for each reading. This comment will be stored against the reading when
you save the file. In the row for which you wish to add a comment, click in the Comment column
and type your text. Copy and Paste functions work identical to the single file data tab.

If you combine more than 10 charts into a multi chart, the data tab is not available. Dew
point readings are not shown in the multi chart data tab.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 5 of 17
Dew Point
(implemented in version 3.1r9)

Starting with version 3.1r9, dew point can now be shown on chart, data and summary tabs.

The dew point shows as an extra line on charts for temperature and humidity loggers, such as the
HASO-8, HAXO-8 or UHADO-16.

By default, this feature is disabled. You can enable it in Options in the section about Charts.

If the dew point line is enabled, you can toggle it off and on by right-clicking anywhere on
the chart and clicking the Dew Point entry:

If the dew point line is disabled, this menu entry is not available.

Dew point lines are not currently supported on multi-charts.

For more information, please refer to the LogTag® Analyzer User Guide or the built-in help
function.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 6 of 17
Printing Calibration Certificates
(introduced in 3.1r6)

You can now view and print a logger's factory calibration certificate directly from LogTag®
Analyzer.

You can access the certificate:

l by clicking Show Certificate from the


report tab after the logger was
downloaded

l by clicking Certificate of Calibration during


configuration of the logger

The certificate issue date is the date the logger


was first configured.

You can also access the factory calibration


certificate from the report tab when opening a
saved data file, provided the recorded data are
from the period during which the certificate was
still valid.

You will not be able to access the certificate:

l before the logger is configured for the first time. You will not be able to click Show Certificate
until the configuration is uploaded successfully to the logger
l after the logger was adjusted by a third-party calibration laboratory using LogTag® Calibrate
l if the logger is configured after the factory calibration certificate has expired
l if a logger was manufactured before 1. April 2019
l for indicator products
l on a multi chart report

If a logger was first configured with a version of LogTag® Analyzer prior to 3.1r6 you may
still be able to view the calibration certificate. Please note, however, that the certificate
date may differ from that on the certificate issued by your distributor. In this case, the
distributor issued certificate is correct.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 7 of 17
New email and file upload options
(introduced in version 3.1r5)

Office365 email support


LogTag® Analyzer can now connect to Office365's SMTP server using your Office365 account.

To use this method, select Email settings in Edit - Options - Automation.

Complete SMTP Server, Port and SSL/TLS fields as follows:

Server Name: smtp.office365.com

Port Number: 587

Encryption Method: Enable SSL/TLS

Click Use User Name and Password and type your Office365 account email into the User Name field
and your Office365 account password into the Password field.

Figure 1: Settings for Outlook 365

If you use two factor authentication for your Microsoft account you will need to perform extra
steps, or sending emails will fail:

1. You will need to generate an app password that specifically allows connection to
applications that are unable to accept two factor authentication passwords.

This is done on the Security basics page for your Microsoft account, in the More security
options section. Create a new app password (or use the existing one). Please refer to the
Microsoft documentation on this subject if you need further assistance generating this
password.

2. Once generated, enter this password in the Password field.

You can now complete the remaining entries in this window, then test the SMTP settings by
clicking Send Test Email .

Settings when connecting via SFTP


SFTP (SSH File Transfer Protocol) creates an FTP link using a secure data stream. In addition to
authentication via Username and Password, LogTag® Analyzer offers authentication via a
Public/Private Key Pair.

If you wish to know more about asymmetric cryptography please refer to one of the many
books or articles available on the topic.

When selecting Password, you provide the same details as you would for a standard FTP
connection, except that the default port is now 22.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 8 of 17
When selecting Private Key, the entries change to allow you to specify the key pair for the
authentication.

The key pair is provided via one of three methods:

1. They key pair is generated on the SFTP server, and the public key is added to the list of
authorized keys that the server allows by the server administrator.

You will need to obtain and import the private key into LogTag® Analyzer. To do this, click Load Key...
and browse to the private key file you have received. LogTag® Analyzer accepts OpenSSH
and PuTTYGen keys. If the key was sent to you in OpenSSH format the file name may not
have a file extension, and may not be displayed in the file explorer window that opens after
you click Load key... . In this case, click the down arrow next to Private Key File and select All
files.

The key may be protected by a password. You can enter this password in the Key Password
field.

Note: If the key is protected by a password, you must enter this in the password
field before you load the key, or you will receive an error message.

You should now be able to test your connection.

2. The key pair is generated by LogTag® Analyzer and the private key is instantly added to
LogTag® Analyzer.

Generate the key pair by clicking Generate keys . If you wish to protect the private key with a
password enter it before generating the key.

A file explorer window opens and you are asked to save the public key to a file. Browse to a
suitable location, enter the name for the key and click Save .

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 9 of 17
Forward this file to the administrator of the SFTP server, so you can be included in the list of
authorized users. LogTag® Analyzer generates a 2014-bit RSA key (stronger keys can be
generated via method 3).

We recommend you create a backup copy of the private key and store it in a safe location. To
do this, click anywhere in the private key field and press CTRL-A, then CTRL-C to copy the
key to the clipboard. Press the Windows button ( ) on your keyboard, type notepad and
press Enter. Press CTRL-V to insert the contents of the clipboard. Save the file to a private
location on your PC. Enter "yourkeyname.ppk" (including the quotation marks) as the file
name to save it as a Private PuTTY Key.

Testing your connection cannot be done until the server administrator has advised you that
the key has been added to the list of authorized users.

3. A third-party program is used to generate they key pair, such as PuTTYgen or SSH-keygen.
This would require you to generate the key pair, save send the public key to the server
administrator and import the private key into LogTag® Analyzer with the method described
above.

Please discuss any further issues with your network administrator.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 10 of 17
Improvements
As always, we have made some improvements and corrected some issues from previous versions. A
selection of these can be found here. Please refer to the release notes for a full list of changes.
Details for each feature can be found in the LogTag®Analyzer User Guide or via the built-in Help.

Improved time entry in configuration and profile dialogues


(implemented in version 3.1r9)

We received a lot of feedback from customers, unhappy with the way times are entered. We have
listened, and have now implemented the same simple entry as was present in LogTag®Analyzer
version 2:

Select seconds, minutes or hours, then change the number to suit. You can click the up or down
arrows, or type a number value directly.

If you want to use a log interval such as 1 minute 30 seconds, enter the number in full
seconds.

Exporting XLS files


(implemented in version 3.1r9)

You can now use Save as from the File menu and select the *.xls option. This creates a file that can
be opened directly with MS Excel. It contains two tabs, one with a listing of the readings, including
index, date, time, elapsed time, events and comments, the second with the contents of the
summary tab. Files from loggers with a day summary will contain a third tab showing that
summary.

Additional Zoom values


(implemented in version 3.1r9)

You can now select two additional default zoom values when opening charts:

l from last download mark to the end of the recorded data


l from last inspection mark to the end of the recorded data

Hiding readings on a multi chart


(implemented in version 3.1r9)

You can now hide all humidity readings, or all temperature readings on a multi chart. A tick will
indicate the readings that are hidden. To show these readings again, click the entry once more.

If the temperature readings are hidden, and you click Hide Humidity Readings, the
temperature readings will be shown and the humidity readings hidden.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 11 of 17
LogTag® Online Connection Wizard
(changed in version 3.1r9)

We have simplified the way you connect your products to the wirelss network. For up-to-date
information please view the documentation for the wizard.

Improved Chart Scaling for Humidity Loggers


(implemented in version 3.1r7)

We have improved the way we display a combined Humidity and Temperature chart by reducing
the overlap of the humidity and temperature graphs. This will make both graphs for HAXO-8,
HASO-8 and UHADO-16 models more readable.

Low-Battery Loggers
(implemented in version 3.1r7)

We have added an option so users can always block configuration of loggers with low battery. This
option can be enabled in the Automation tab of the Options window, available from the Edit menu.

Although we allow you to configure several logger models even with a low battery, so you can
maximize their use, you should enable this option, particularly if your loggers are used in
applications with long transit times.

Customizing the CSV date format


(implemented in version 3.1r7)

You can now customize the date format for exported CSV files. This makes it easier to integrate
the generated files with third-party applications requiring a specific format.

Prioritize download over file generation


(implemented in version 3.1r5)

We have removed this configuration parameter for all USB loggers. It will now always get enabled
during configuration.

Expanded Temperature Ranges


(implemented in version 3.1r5)

We are able to adjust the lower limit of the temperature range of UTRIX-16, USRIC-8 and USRIC-16
loggers to -30 °C for product manufactured after 1 Jan 2019 due to an upgrade in one of the
components used in those products.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 12 of 17
Warning for unsupported configuration settings
(implemented in version 3.1r5)

We added more detailed information about unsupported configuration settings when using
configuration profiles or configuring multiple loggers.

When the configuration panel shows a warning, a tooltip now shows information which of the
settings cannot be applied for a specific logger, for example when configuring loggers with
different alarm capabilities:

Themes
(implemented in version 3.1r5)

Regrettably we had to remove the support for the selection of themes, as they were causing issues
with a number of the software's features, that we were unable to resolve.

USB Logger Description field


(implemented in version 3.1r6)

Until version 3.1r5, the description field in USB loggers only accepts ASCII characters due to a lack
of font support in the on-board PDF. Some clients found this too restrictive, so effective version
3.1r6, LogTag® Analyzer allows entry of Unicode characters into the description (and password)
fields. As a result, you may see unrecognizable characters in the on-board PDF file, while LogTag®
Analyzer will display the correct characters on-screen.

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 13 of 17
Bug Fixes
As with every release you, our clients, have identified several issues, which we fixed with this
release. Thank you to all who have brought these to our attention. Here is a complete summary of
the changes, including improvements made.

3.1 release 9

l Added support for new logger model UTRED-16


l Added dew point calculation for humidity data
l Log Interval and Start Delay can now be entered the same way as LogTag® Analyzer 2
l Upper and lower alarms can be configured separately for HAXO-8, SRIL-8/TRIL-8, TREL-8
and TREX-8
l Added export to MS-Excel XLS file for data tabs
l Humidity and temperature lines can now be switched off independently on multi charts
l Added options to automatically zoom opened charts from last download mark to end, or from
last inspection mark to end
l Added support for PDF language selection for USB PDF Loggers models that support this
option
l Allow profile configuration of UTRED30-Wifi without updating current WiFi settings
l Added Portuguese language support
l Add new improved version of Connection Wizard and allow to configure WiFi network
credentials from configuration dialog for UTRED30-Wifi
l Windows quick search will now find the Analyzer3 shortcut when searching for 'LogTag'
l Annotations can now be dragged outside the bounds of a chart
l An LTO password is not stored when "Remember password" is not selected
l Corrected time zone display in text-based file exports to match Analyzer display time zone
settings
l UTRED30-Wifi: Allow storage of SSID when WiFi password empty
l Replace unsupported characters in .ltd file name, before saving the file
l Use number format from Windows regional settings for new profile dialog
l Display re-calibrated readings markers for USRIC-4 models
l Improved application memory management to prevent "Out of memory" errors
l corrected HAXO-8 extra reading presented for specific logger configuration

3.1 release 8

l Corrected TRID30-7/TRED30-7/TRED30-16R consecutive alarm statistics calculation


l Digital Signature can be saved now for ltd file
l Allow auto-export for text files when export in .CSV not enabled
l Corrected view of humidity readings when humidity value match temperature upper limit
and had > symbol

3.1 release 7

l Added support for the new USRID-16 model

l Added Japanese and Chinese (simplified) language support

l Added user option to always block configuration of Loggers with low battery

l Added option to customize the date format for csv file exports

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 14 of 17
l Added display of Min/Max Reset markers to Multi Chart legend

l Adjusted logger specification lower limit for UTRIX-16, USRIC-8 and USRIC-16 loggers
manufactured after 1.1.2019

l Improved user experience when downloading a corrupted or unsupported logger, or opening


a corrupted file

l Improved chart scaling for HAXO-8, HASO-8 and UHADO-16 models

l Application can now be run with Windows FIPS Mode enabled, allowing files to be written
and opened

l Corrected application of "Default time interval to display" setting when opening a data file

l Aligned display of USRIC-4 readings with LogTag Analyzer version 2.9

l Corrected display of previously configured Date/Time start time for non-USB loggers

l Corrected problem with data files downloaded via HID or Wireless interfaces when stored in
Multi Chart file

l Added Summary statistics settings to text export function

3.1 release 6

l Option to view and print a calibration certificate is available for loggers manufactured after
April 2019

l All Loggers: In File - Properties, corrected the "Data originally acquired" field In some cases
this could use the wrong time zone

l All USB Loggers: Improved robustness to recover from logger memory corruption. There will
be fewer instances of corrupt calibration errors

l All USB Loggers: Allow Unicode characters in USB/PDF logger description field to allow
localized content (Note: Unicode characters are not currently supported by USB logger
firmware, so PDF files generated may contain unrecognizable characters)

l USRIC-4: Add “push button start from hibernation" start mode to allow start delay to be
configured and used. Use this mode instead of standard push button start as current models
may start immediately even if start delay is configured in standard push button start mode

l USRIC-4: When a start delay is configured, automatically set to “Push button start from
hibernation" and disable pre-start logging. This works around an issue with current models

l USRIC-4/USRIC-8/UTRIX-16/UTRID-16: Corrected statistics for zoomed values for USB multi-


alarm loggers

l TRIL-8/TREL-8/SRIL-8: These loggers can no longer be configured together or with each


others profiles. This avoids unexpected results during configuration

l HAXO-8: Corrected behaviour where in rare circumstances an extra fictitious reading would
be shown

l TRID30-7/TRED30-16R: Upper and lower alarm thresholds now use more accurate values.
This prevents readings reported as acceptable to trigger an alarm and vice versa

l Several improvements to file open and save behaviour where non-existent, or invalid file

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 15 of 17
path are used

l Use correct decimal place symbol (e.g. comma ',' or period '.' character) as defined by the
local PC region settings. Effects both LogTag Analyzer and exported files

l All USB Loggers: The brand name displayed on the on-board PDF report and in the file names
is now as intended

3.1 release 5

l Added the option to generate Factory Calibration Certificates for loggers and files

l Added Data view for Multi-Charts with up to 10 files

l Added French Language for selection

l A configuration profile issue for USRIC-4 loggers has been resolved

l Corrected the number of starts displayed in Report for multi-use loggers

l Aligned data list display of alarm readings with LogTag® Analyzer version 2

l Corrected chart display of sensor disconnected readings for TREX-8 and TREL-8 loggers to
match the display of LogTag® Analyzer version 2

l Updated the Set Timezone method for Vaxtag® loggers

l Corrected various issues when importing and exporting option settings

l Aligned HAXO-8 low battery display with LogTag® Analyzer version 2

3.1 release 3

l Battery test during configuration of TRIL-8 and SRIL-8 loggers has been improved

3.1 release 2

l Corrected an issue where, in some cases, temperature loggers that were adjusted using
LogTag® Calibrate showed incorrect values near both ends of the product’s temperature
range

3.1 release 1

l Corrected download for USB loggers started via push button without start delay

l Update imported profiles to show correct start delay in edit profile dialog

l Corrected issue with temporary files that caused non-admin user being unable to open .ltd
files with Explorer double-click

3.1 release 0

l Added information about unsupported configuration settings when using configuration


profiles or configuring multiple LogTags together

l Added SFTP protocol for file upload

l Added support for new products TREL30-16, UTRED30-16 and UTRED30-Wifi

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 16 of 17
l Added support for user resettable Min/Max, including chart displays and Report Event info

l Corrected "Push button start from Hibernation" setting in profile

l Corrected Auto-download button behaviour according to configuration

l Corrected email settings that lead to rejection of support emails sent from Gmail accounts

l Corrected total log duration calculation in Configuration Log

l Fixed a bug with the 3.0r8 installer where additional user accounts are prompted to run the
installer again to verify files

l Fixed program freezing issue with Analyzer when a computer exited sleep mode

l HAXO chart: Show correct x-axis labels for humidity chart when temperature chart is
disabled

l Improved display markers for re-calibrated readings for USB-LogTags

l Improved display of sensor disconnected readings in file exports

l Improved handling of page margin units in Page Setup dialog

l Improved Hibernate function

l Improved overall stability of the application

l Improved PDF export: Removed empty pages, improved receiver notes, page number
positions

l Improved Report and PDF Report layout for languages German, Spanish and Russian

l Re-set HAXO re-calibrated markers on configuration

l Sending emails: Added support for Office365 mail servers

l Themes are no longer supported

l USB LogTags: Configuration now always enables the “Prioritise download over file
generation"

What's new in LogTag Analyzer 3.1 Copyright © 2004-2020, LogTag ® Recorders Page 17 of 17