321-78086A, May. 2015 & SHIMADZU ELECTRONIC BALANCE BLSERIES BL320S, BL620S, BL3200S, BL220H, BL320H, BL2200H, BL3200H(L) INSTRUCTION MANUAL SHIMADZU CORPORATION ANALYTICAL & MEASURING INSTRUMENTS DIVISION KYOTO, JAPAN Requests + Provide this manual to the next user in the event that the instrument is transferred, + To ensure safe operation, contact your Shimadzu Balance representative for installation, adjustment, or reinstallation after moving the instrument to a different site. Notices + The content of this manual is subject, without notice, to modifications for the sake of improve- ment + Every effort has been made to ensure that the content ofthis manual was correct at the time of creation. However, in the event that any mistakes or omissions are discovered, it may not bbe possible to correct them immediately + The copyright ofthis manual is owned by Shimadzu Corporation. Reproduction and duplica- tion of whole or part of the content without permission of the company are strictly prohibited. (©)2000-2015 Shimadzu Corporation, Al ights reserved Notation Conventions G Note This instruction manual uses the following notation conventions to indicate Safety Precautions and additional information. Fon Iiates a potently hazardous situation that ma L\ Caution Comte) y result in injury to personnel or equipment damage. o note Provides additional information needed to properly use the balance, Safety Precautions | tbesticty observed To ensure that you use the balance safely and correctly, read the folowing precautions carefully and observe them, ‘The levels of danger and damage that will arise ifthe balance is used incorrectly are classified and indicated as shown below. Indicates a potentially . Indicates potential, hazardous stuation whieh, PANU inot avoided, coud resutin | PANGLULE UIE not avoided, may resuit in minor to maderate injury oF ‘serious injury or possi iy or possibly dest equipment damage, Precautions are classified and explained by using one of the symbols below, depending on the nature of the precaution. Indicates an action that mustbe Indicates an action that must performed. NOT be performed. Never disassemble, modify or attempt to repair this product or any accessory. ‘You could sustain an electric shock or the product could operate abnormally. Ifyou beleve thatthe balance has fale, contact your Shimadzu representative Use the balance with the correct power supply and voltage. Use the balance with the attached AC adapter. lnsvetene Using the balance with an incorrect power supply or voltage will lead to fre or trouble withthe Balance. Note also that ithe power supply or voltage is unstable or ithe power supply capacity is insufcent, it wll not be possible to obtain satisfactory performance from the balance. Use the correct weighing units. Using incorrect weighing units can lead to accidents asa result of weighing eros. ‘Check that the weighing units are correct before starting weighing @ © © Do not use the balance outdoors or anywhere where it will be exposed to water. ‘You could sustain an electric shock or the product could operate abnormally. @ 4A\ CAUTION S ‘Avoid locations where the balance 9 & my ‘This could cause accidents or poor performance, Airflow fom an ai conditioner ventilator, door or window Pe + Extreme temperature changes fe * Vibration OS ue cae ey a + Dust, electromagnetic waves or a magnet fle Install the balance on a strong and stable flat table or floor in the room. Pacing the balance in an unstable site could lead to injury of trouble with the balance. |When selecting the installation site, take into account the combined weight ofthe balance and the iter tobe weighed ‘After a power outage, turn the power back ON. When a power outage occurs, the power is shutoff automaticaly. Therefore, begin ‘operation from 2. INSTALLATION (@)(~ page 4) again. ‘Treat the balance with care and respect. ‘The balance is a precision instrument. Subjectng it to impacts could cause itt fll |When moving the balance, remove pan and pan supporter, Grasp it frmly with bath hands to carry t Ifthe balance has tobe stored for along time, store it inthe packaging box in which it was delivered. Do not connect anything other than peripheral devices specified by ‘Shimadzu to the balance’s connector. Ifyou do, the balance may stop working normal In order to avoid trouble, always connect peripheral devices in accordance with the directions In this manual IFyou detect anything abnormal (e.g. a burning smell) disconnect the AC adapter immediately. Continuing to use the balance with an abnormality could lead to fre or an electric shock S @ S “We Action for Environment (WEEE) To all user of Shimadzu equipment in the European Union: Equipment marked with this symbol indicates that it was sold on or ater 13th August 2006, which means it should not be disposed of with general household waste. Note that our equip- ment is for industia/professional use only. Contact Shimadzu service representative when the equipment has reached the end of its life. ‘They will advise you regarding the equipment take-back With your co-operation we are aiming to reduce contamination from waste electronic and electrical equipment and preserve natural resource through re-use and recycling Do not hesitate to ask Shimadzu service representative, if you require further information. = WEEE Mark ve 6.1 1, 7 12 8, 9, 10. I. CONTENTS COMPONENTS AND THEIR NAMES. 1 INSTALLATION. 3 WARM-UP... 4 CAUTION NOTES . 5 MESURING PROCEDURE... 5 MENU SELECTION a 6 Menu selection when “F yn. $ £ t” isselected 8 6.2 Menu selection when “int F AE Eis selected 10 SENSITIVITY CALIBRATION... n Setting the value of sensitivity calibration weight... 1 Sensitivity Calibration 13 REGISTRATION, CANCEL, AND CHANGE OF UNIT 14 % SETTING 15 PCS (No. of pieces) SETTING 16 PERFORMANCE CHECKS... _17 MAINTENANCE... . 18 12, 13, 14, 15, 16, 16, 16, 16, 16, 17, TROUBLESHOOTING... SPECIFICATIONS... PARTS LIST... “ PERIPHERAL DEVICES.. sone 1 The EP-80 Flectronic Printet...mnimnmnninnnnnnnnnnnnannnn 22 2 The IFB-102A RS-232C Interface. 2B 3 Inputloutput Format 25 4 Command Code 26 Detailed Information on Unit Conversion... 27 COMPONENTS AND THEIR NAMES Components | Included with every balance are one of the following items, * Balance body ‘= AC adapier (option) « protection cover Pan ‘© Pansupporter © Instruction manual ‘+ Inspection certificate * Breeze guard (Only type, BL-220H and BL-2201D. oN Oo LP rapass longitudinal direction, a) ‘Atached only for BL-220H and BL-320H1, Place the hoe to slightly le and) — longitudinal direction. © Balance body © Pan © Pan supporter @ Pan shatt D Level gauge @ Power jack © Level screws @ places) © Protection cover © AC adapter (option) ® Data VO connector @ Breeze guard (OnlyBL-22011 and BL-3201) © Breeze guard cover (Only BL-220H and BL-3201) Display and keypad Display Sensitivity calibration mark (Communication mark FI N mg mom [ cq ctw Pr 20s BATT AP WARMUP Analog indicator Auto print mark Standby mark Unit marke Keypad {POWERIRK) key + Selects Operation/Warm-p. + Cancels calibration or ment CALMENT] key /—(EARE] (Taring) key + Performs calibration, 7 ‘Clears the display to zero, te) ce ara Fa a wy oy Gm Cy UNIT] key ‘+ Selects unit. / / + Sets % ot No.of pcces / «+ Sets value of sensitivity calibration weigh. / PRINT] key ‘+ Outputs the displayed value to a printer or other extemal equipment + Ses value of sensitivity calibration weight Check power voltage LX caution LX caution AXcaution LX caution LX caution Installation site Caution Note Installation (1) @) 2. INSTALLA’ = Use only the AC adapter provided by the distributor who is authorized by Shimadzu Corporation. ‘© Check the power supply voltage. ‘+ Check that the supplied power voltage satisfies the displayed value on the AC adaptor. ‘+ In order to prevent el 4 3P plug with a grounding line or a 2P plug after connecting the grounding wire to the screw at the back ofthe case. tric shock when connecting the power, use ‘* Do not place anything that makes it difficult to pull the AC adapter off the outlet. Install the balance on a strong and stable flat table or floor in the room, Avoid installing the balance in a place where: Its exposed to corrosive gas or flammable gas; It is exposed dust, wind, vibration, electromagnetic waves, ot @ ‘magnetic field; Itis exposed to direct sunlight or a sudden change in temperature; or Itis exposed to extremely high or low temperature or humility Remove the protection seals (4 places) from the protection cover and then put it on the balance body. Tum the level screw so that the air bubble on the level gauge is positioned at the center of the red circle, Make sure thatthe balance never jolt For easy adjustment, insert the level serew on the right back foreibly to the balance body. Then while lightly pressing the balance top with your hand, adjust the horizontal level with the level serews on the right front and left front. Finally, in order to make the balance stable, adjust the right back serew to touch the floor. This procedure allows you to level the balance quickly. @ © @ ®) © Place the pan supporter on the pan shaft Z as a CHES ‘and then the pan on the pan supporter. ; Plug the AC adapter into the outlet. CHES The balance shows oF F after : self-checking. THET Press the [POWERIBRK ] key. All : displays light for one minute, Then oFF the display automatically shows "zero" 8888888 and the balance enters measurement ready state, noo Press the [POWERIBRK ] key again ‘The standby mark lights up and the sis balance enters standby state. Warm up the balance. Calibrate the sensitivity. Refer to “7. SENSITIVITY CALIBRATION”. Check the performance, Refer to “Il. PERFORMANCE CHECKS" ‘© Apply power in advance for one hour or more. This will allow you 10 immediately make an accurate ‘measurement. ‘+ Even if the balance is not used, keep the standby mark lit (warm-up state) by pressing the [POWERIBRK ] key without disconnecting the AC adapter. If the balance is not used for one month or more, disconnect the AC adapter. ‘© put water, metal pin or any thing in the balance; ‘= open the balance case ‘+ leave anything exceeding the weighing capacity on the pan; ‘© expose the balance to anything magnetized; ‘© connect anything other than the specified equipment to the connector on the rear side of the balance; and. ‘© give a shock to the pan. MEASUREMENT PROCEDURE Preparation ‘Warm up the balance. for Weighing Making a (1) | Press the [POWERIBRK ] key. The Peeeeee measure- standby mark goes off and all displays ment light. Check that there is no segment mode which isnot lt (2) | The balance shows zero and enters the > 288 ‘measurement mode Measurement | When using a tare, load the tare on the (2) | pan and press the [TARE ] key after a stability mark is lit = 123000 (2) | Check that the display shows zero. (3) | Load sample. When the stability mark is lit, read the display. If the total mass of the sample and tare exceeds the weighing capacity, oLwill be displayed. # Tat seosnnsnnnnninne A Sample container oF other «© Stability mark ().....Lights when the displayed value falls within the stability band, When the load change is slow, the displayed value will flucutate with the stability mark lit This balance is designed to permit selection of the measuring conditions to compensate for vibration and other conditions present at the installation site, This feather permits greater weighing efficiency and accuracy, and is referred to as “Menu Selection”. Also in BL series, seting the balance to “$ & -d” (standard measurement mode) ‘makes a normal measurement and requires no other setting. ‘The menu in the BL. series consists of thee classifications. Basically press the [TARE] key to go to lower hierarchy, and press the [POWER/BRK ] key to retum to upper hierarchy. ‘Continuously pressing the key retums the display to weight display from, cach hierarchy with single operation. Step (2) | _ Press the [CAL/MENU ] key during the weight display. @) | + £8 willbe displayed. @) | Every time the key is subsequently pressed, the display be changed in the order shown below (4) | Select the desired condition and press the [TARE] key. Then, it will be set or enter into the lower hierarchy. Bb08 Weight display CAL Sensitivity calibration mode St bS & Currently set condition Stad Standard mode | SAaPLE Sample pouring mode | He-Sktb High stability mode Func. SEL Enters second hierarchy menu, Advanced measurement, unit registration, and | individual setting mode Refer toSecton 61 Memuseesion wien" Fy nce, § E Liss” EAL SE & —_ Enterssccond hierarchy menu, Setting the value of sensitivity calibration weight | => Rete to Section 7.2 “Setting the value of sensitivity calibration weight”. tm EE ALE Enters second hierarchy menu. i | => Refer to Section 6.2 “Menu sel utfoutput format setting mode tion when on E F AE E “isselected”. eso) Weight splay + Ifthe measurement is done at severe measurement environment and the stability of the display is not so good, set the balance to“H + - 5 & &" (high-stability mode). © When the high-speed sample pouring mode is executed, or the small mount of sample pouring is done, set the balance to“ § Am P L E” (sample mode). 6.1 Menu selection when “ Funf. SE selected Pressing the [TARE] key when the “Fynl. SEL” is ‘menu enters 2nd hierarchy ment. In this menu, ON/OFF of zero tracking, setting the stability detection band, registration/cancel of unit, ON/OFF of auto print, and ON/OFF of analog display are made. Key operation and each setting are made as follows. isplayed at Ist hierarchy Fone. S€tp ere Ere-on — Zerotacking ON | - la 1 Eres oF — Zerotracking OFF biped Stability detection band 1 count 1 ‘Stability detection band 5 counts ‘Stability detection band 10 counts Une & — eumit selection kg kg unit selection tunit selection No. of pieces unit selection 5% unit selection Troy oz unit select Penny weight unit selection Grain unit selection Hong-kong tail unit selection Singapore tail unit seltion ‘Taiwan tail unit seleeection Malaysia ail unit selection Japanese "monme” unit selection Lb pound) Taiwan tel? Taiwan tel* “Taiwan tel® Sawaran® 2 none Kyatst 3 none Custom* Auto printing is done. Auto printing is not done. Analog display is done. Analog display is not done (©) : Press the [TARE] key. (<) : Press the [POWERIBRK ] key. (Press the [CAL/MENU | key. When set ob ~ # , satisfactory for most use, the stability mark lights when the display stays within +1 unit (the resolution value of the balanes) fora fixed period time. When the display shows “Ere ces Bi 6+ 4, RP ee: Ad «SP ces”, the currently set conditions are displayed on + Zero tracking eliminates zero drift, and should be on ( tr ¢ - om ) for normal weighing. When measuring weight changes over time, or when slowly adding a liquid or powder fo the balance, tum off( kr ¢ - oF F )the zero tracking feature. * Itccan be selected in special Area only. 6.2 Menu play when sn E FACE selected Pressing the [TARE] key when the “in £ F ALE ” is displayed at Ist hierarchy ‘menu enters 2nd hierarchy ment, In this menu, the input/output format can be set. int FACE va, b: 3006 3006 1 boob It 12008 la e4o05 ly "aonb la 96005 1 tad: fe 7— be - Ia 4 tr It rte {t 1 10. P: non 1 10. 5: $2 L__ (2) : Press the [TARE ] key. (©) : Press the (ROWER BRE] key. (Y) : Press the [CALIMENU ] key. ‘+ When the display shows “ conditions are displayed on ws. -10- ad te, 300 Band a, 600 Bad rt, 1200 Ba te, 2800 Bad te, 800 Delimiter, AR Delite, Delimiter, CR and UF Dette, comma Pay. even Pay. xd Paty noe Srp bit Srp bit? ab 9% 60.0 64 10,P #8 10.5 98”, the currently set SENSITIVITY CALBRAT! ‘The electronic balance measures mass by electronicity compensating for terrestrial gravitation, Since gravitation varies slightly in different regions, span calibration (sensitivity calibration) is required when the balance is installed. Temperature also effects balance accuracy, and calibration must be performed whenever a significant change occurs. It is ‘good practice to calibrate the balance whenever the balance is moved or unexpected shock is applied to the balance such that an article drops on the pan, 7.1 Setting the value of sensitivity calibration weight In this balance, the value for sensitivity calibration weight can be set freely within the specified range. Using the weight having known value, sensitivity calibration can be made. Set the weight value using at sensitivity calibration as follows. Step (2) | Following the menu selection, press the — [ALIMENT] key 19 make the display EAL SEE CAL SEt ™ (2) | Press. the key to set the Balance to weight set mode @) | The weight value currently set is “200008 displayed and the digit to be set blinks, When the weight value is not changed, Ina} lca| le3| lea| lea] lea| press the key. (4) | Pressing the [PRINT] key shifts the blinking digit. () | Pressing the key counts up the blinking displayed value. eb00o3 (6) | _ Repeats the steps (4) and (5) to set the ‘weight value, @) | When aborting the setting, press the Abort POWERIBRK]key. Then“ Ab orb ” is displayed for several seconds, the balance stops the setting of weight value and retums to weight display. ole 8) (9) (10) Afier the setting of weight value is completed, press the [TARE key. “SEE is displayed for several seconds and the balance retums to weight display When setting the weight value exceeding the specified range, “£20” is displayed and then the balance returns to weight display. ‘The settable weight value is follows. More than 150g and less than More than 150¢ and less than BL3208 BL320H weighing capacity weighing capacity ne More than 300g and tess than | 1 yoqy, | More than 1000g and less than weighing capaci weighing capacity waLs200s | More than 1500g and fess than ] yy sooqy | Mote than 1500 and les than weighing capacity weighing capacity Lott More than 100g and less than weighing capacity “12. 7.2 Sensitivity Calibration Perform the sensitivity calibration as follows. Step (2) | Warm up the balance well. Refer to“3. WARM-UP” @ | Check teveting ) | Unload the sample on the pan and press the 3a] Key to zero the display. @) | Following the menu selection, press the [CALIMENT] key to display“ CAL”. “aaa (5) | Press the [TARE] key to start the aa sensitivity calibration aPeonoo © | The set weight value appears and blinks, (7) | Make sure that the stability mark is lit, (8) | Place the calibration weight on the pan. ebonag At this time, the stability mark will ‘once disappear. (®) | When the stability mark is lit agsin, [Seno a00 press the [TARE] key. (20) | The display shows zero and blinks. Make sure that the stability mark is lit 2.8 8. (41) | Unload the weight =a (42) | When the stability mark is lit again, press the [TARE] key. (43) |< CRL End © is displayed for several seconds and the balance retwms — LEAL End to weight display. This completes the sensitivity calibration. (14) | If the different weight is used for this [EAL EY sensitivity calibration, * CALE 4” is displayed for several seconds and the balance returns to weight display. Check the weight and retry the sensitivity ealibration, -13- 8. REGBTRATION, CANCEL, AND CHANGE OF UNIT Step for registration (1) @ @) @ 6) Stepforcancel (1) Stepforchange (21) Press the [CALIMENU] key and select the Fun. SE t display. (Press the [TARE] key.) Press the [CALIMENU] key and select the (Press the [TARE] key.) ‘The registrable unit is displayed by every pressing the [CALIMENU] nok. SEL display key. The registerable units are three kinds which are selected from the following 14 kinds. 8, kg, ct. pes, %, 02, o2t, dwt, GN, Hong-kong tail, Singapore tail, ‘Taiwan tail, Maraysia tail, and Japanese "monme" However, % and pes (No. of pieces) cannot be registered simultaneously. ‘The stability mark is it on the unit display currently registered, Press the [TARE] key on the unit display to be registered, That unit is registred, ‘When three kinds of unit are already registered, a new registration deletes the oldest registration among the three registered units. However, % and pes (No. of pieces) cannot be registered simultaneously. Then deletes unnecessary one Continuously pressing the key returns the display to weight display. Carry out the same operation described (1) to (3) above to set unit display, Selecting the same one of the unit display which is currently registered (stability mark is li) cancels the registration. Pressing the [UNIT] key changes the unit which is already registered, However, even if the unit of % and pes is already registered, the display does not change to this unit unless making a setting of reference value, old This balance serves percent (%6) display by setting the reference sample to 100%. Step (2) | Register the % unit. (Refer to “8. Registration, cancel, and change of unit” ‘When % unit has been already registered, iis not necessary to register again (2) | Place the tare on the pan and press the Boo [TARE] key. Set io0% (3) | Load the reference sample. @) | Continuously press the [UNIT] key to SEE display" SEE 100%” ©) | After the stability mark is lit, press the Per oe TARE] key. (6) | “SEE ™ is displayed for several seconds and the balance enters the % unit display. Minimum displayed value changes as follows depending on reference sample weight (REF) Referense sample weight (REF) is count value which minimum displayed value rearranges If the % conversion is not possible, fone count. Eee 20 “is displayed for several seconds and the balance returns to weight display. ‘Type H. REF < Minimum diplayed value = 100 conversion impossible Minimum displayed value » 100 , REF. < Minimum displayed value « 1000, sre Minimum displayed value » 1000 REF. < Minimum displayed value «10000 100.0% Minimum displayed value» 10000 , = REF. < Minimum displayed value «100000 foams Minimum displayed value » 100000 = REF 100,000% ‘Type S REF. < Minimum displayed value = 100, conversion impossible Minimum displayed value » 100 ‘owes < REF. < Minimum displayed value « 1000, Minimum displayed value * 1000 REF « Minn dale vl» 10000 sone Minimum displayed value » 10000 = REE. 00.00% -15- 10. PCS (No. of pieces) SETTING ‘This balance can perform No. of pieces measurement (unit PCS). No. of standard pieces is 10 pes, 20 pes, 50 pes, or 100 pes. When the increased, the accuracy is improved. No. of pieees is, Step (2) | Register the PCS unit following the unit registration. (Refer to “8. Registration, cancel, and change of unit” When PCS unit has been already ica] lea| Ica| Ica| registered, it is not necessary to register [GEE 20 again, (2) | Place the tare on the pan and press the TARE] key. SEE @) | Load the standard sample with required pieces E cree (@) | Check that the stability mark is lit, () | When pressing the [UNIT] key continuously, the display will change as follows: “SEE 18 SEE 2a » “SEt SO “and“SEt Iga ” (6) | _ Select the desired PCS display and press the [TARE key. (7) | “SE” is displayed for several seconds and the balance enters the PCS unit display. of set pieces”, the PCS setting is not made. In this case, “ E + r 2 8” is displayed for several the balance returns to weight display. -16- ‘When the reference sample weight is less than “readability x No. seconds and 11, PERFORMANCE CHECKS Conduct performance checks in a room where the temperature does not change suddenly. ‘These checks are used to determine if the balance conforms to specifications, and should be performed with the greatest care, Preparation Repeatability @ @) ® ‘© Warm up the balance well ‘© Set the measurement condition as follows + Stand ebe stre-oFF Load and unload 10 successive times, ‘an weight which is near the capacity of the balance, Then record the following items Xi: Displayed value when the weight is loaded after stability mark is lit Yi: Displayed value when the weight is unloaded after stability mark is lit Calculate the standard deviation of ‘ox and cy using the formulas shown right. Balance operation is normal when the standard deviation is less than 1.5 times the value specified. oe aye [Sov “a where X, ¥ Average value Eccentric error @ @ When fouled: Prepare a sample which weights : crpsinacy 14 of he tne — [OO] capacity and move it on the pan in the Ore order as shown right. Record the Position of wel results of X1 to XS in this order. rw Posi a IF the difference (eccentric error) between readings at the center position and the off eenter positions is as follows: BL320H, 3200H, : Teounts BL H series: 4 counts BLS series: 2 counts ‘© When the balance becomes dirty, wipe it off using a soft cloth with ‘a small amount of mild detergent. ‘* Organic solvents or chemical dusters should not be used as they ‘may damage painted surfaces and the display panel ‘* When the balance is placed in a dusty or dirty environment, use the protection cover of standard accessory. ‘© The pan can be washed with water. Dry the pan sufficiently and ‘mount to the balance. “18. 13. TROUBLESHOOT! For countermeasures having an asterisk, contact the nearest Shimadzu sales or service ‘The pan orth pan supporter isnot in place, center. Wiss What touble Cause Countermensure Before |» Nothing is displayed by connecting)» The AC adapter is disconnected. weighing | the AC adapter to the outlet. /+ The eletrcal board is wumed OFF. + Er DS is displayed. Je Thore isan internal errr in he lance, => * During |» of is displayed. [> The mast on the pan is too heavy. weighing + Sensitivity is not correct. = ot is displayed. The display fluctuates. “The display does not change from | zero even if a sample having the ‘weight nea readability is loaded. The display slowly changes when | « small amount of sample is loaded. (Normal: readability see.) (0 F F has appeared suddenly. ata communication cannot made. bel Influence from vibration or wind = Improve the instalation site = Change the measurement mode 1 Highs stability mode, Influence from electric nose or electromagnetic =Maintain a proper distance fiom the noise Zero tacking works. = Refer to 6, Mens Selection”. The # ode = Change the measurement mode if necessary “There hasbeen an instantaneous power alr = Press the Key (he balance ters weight display mode) Seating of communication parameters wrong = Refer to “164 Setng the inpuoupu format” Wiring oF RS-732C cable fs wrong aging processing is in High-stabilty During PCS| Eee 20 has displayed ‘Set value exceeds the specified range ERLEY has displayed. Jor % senting = Refer to“9.% setting” and “10, PCS setting”. During |» Does not proceed to next step. |» Influence from vibration or wind sensitivity | (The sablity mark does not ight) | => Improve the installation ste calibration => Change the measurement mode 10 High stability mode, ‘The weight used for sensit ‘wrong. =Check the weight and rey the sensitivity calibration There i an internal ero inthe balance = * ity calibration is -19- Moder BLS Laos BLIMOS Weighing capaci 3208, (20, 32008 Readability 001g Ole Ot Sanda deviation 1.006 001g 1.06 Lineaiy 001g 0.028 Og : 2008 3008 20003 Calibration weight eo an Son Pan diameter (mm) 700100 Iara Main body size mn ‘Approx. 170 QW) 240(D)= 75 (H) mm Main body weight ApprON. 2.2 kg Siability of sensi , (10°C - 35°C) #10ppm°C Applicable tem we perature range Rated electric Ros power supply Pollution Degree z ‘Overvotlage Category Caiegory Aiud Up 0 2000%m Installation Site device may only used indoors ‘AC adapter (primary) "ACIOO-240V. 40m 30/6042 Model BIa20H BLR20H wsian00H | _BLs200H1 Weighing capaci 220g 320g 22008. 32008 Readability C0Tg Doig Standaed deviation (0.0018 01g Tinea Tom; CO Oe 7 Calibation weight 200 3008 2000 30002 Pan diameter (mm) 10 100 (With the guaed) Taxi Main body size (mm | Approx. 170 (W)»240 (Dyx114 (fy mm Approx. 170QW) »240 (DTS GA mm Main body weight “Approx. 2.2 Stability of sensitiv | sremec me) sSPpmec Gece. | Same | Getee | Smmmre | antec) “Applicable tm sure perature range Rated electric pei, 01a power supply Pollution Degree 2 Overvoltage Category Category ‘Alude Up 1 20000 Tasallation Site device may only used indoors ‘AC adapter (primary) TACIO0-240, 40mA S0/60H7 #1: Refer to “7.1 Setting the Sensitivity C #2: 12VDC, 1A FOR BL-L (Backlight Type) libration Weight” -20- 15. PARTS LIST Optional accessories Peripheral devices Parts name Parts No, art Number for ROHS, Remarks Printer EP-100 321-73900-01 Printer EP-110 821-73900-02 Calibration weigh 200g | 321-5346 For BL220H, (OIML FI class inthe box) 3201 For BL3208 500g | 321-3447 For BL620S 2kg | 321-53449 For BL2200H, 32001) For BL 32008) HORS cable 321-71260-01 USB serial adapter 5321-62520 Printer EP-80 BreAC cannery | befelAe saspt0r) Printer EP-90 maintenance parts Parts name Pants No Remarks Pan (small): For 3205. 220H1, 3208 an (Large): Fer 6208, 32008, 2200H, 3200H (L) Dan supporter (Small): For 3208, 220H, 320H 321-53908-11 Pan supporter (Large): For 6205, 2200H 321-53908-01 Pan supporter (Large): Fer 32008, 3200H L) 321-53908.02 Gaara 321-53901-01 Guard cover 321-55654.02 Protection cover (Spe) 321-61226 Level screw 321-53530.30 2 16. PERIPHERAL DEVICES 16.1 The - Electronic Printer Connection When connecting this balance to the """™ , first be sure to pull up the AC adapter for the balance and sm» Then connect to data VO connector as shown below. electron printer Functions Manual ‘The displayed value is printed whenever the [PRINT] key is pressed. printing Autoprint In the g display of the balance, when the display is within zero + 3 count, the display is stabled when the sample over 20 counts of g display is loaded, the balance automatically prints out, Unload this sample and wait for the display falls into within zero = 3 counts, then load a next sample. Statistic Pressing the [STAT] key statistically calculates and prints the data calculation until next pressing of the [STAT] key. See Instruction Manual for Electronic Printer * for further details, 16.2 The 1/0 RS cabl This cable isused when the balance is connected to a personal computer. Connection ‘When connecting the cable to the balance, be sure to pull up the AC adapter for the balance, Then insert the plug of cable into the DATA VO connector of the balance. VORS cable Signal TaNo | Sigal [10 Funston Z| TXD | Oupat_| Dats our 3 RXD Input __| Data Input 3 _[ se Ground -23- 24. 16.3 Inputbutput Format — means space and [DE] means delimiter. Input data Output data Data format Command code + [DL Refer to “16.5 Command Code”. ‘ For mass display $+. 1000,008. [BE] Unit At L-byte: Unit + At2-byte: Unit At3-byte: Unit Polarity Atplus: Space (..) At minus Stability information (only at output with stability information) Atstable: S$ Atunstable: U Foro ot display Uonpemann Greyman Polarity Atplus: Space () Atminus: Minus) Stability information (only at output with stability information) Atstable:S Atunstable: U * ASCII (JIS) code ‘* Baud rate, parity, and delimiter change depending on menu sele -25- AXcaution 16.4 Command Code Described in this section are the command codes which can be used when your BL balance is connected to @ computer via the VO RS eahle ‘The use of characters other than those described here will cause errors in weighing and data transfer procedures. If'an improper code is mistakenly entered, disconnect the balance power cable for 10 seconds, then reconnect. ‘Command code Function Description T Tring TEquivalent to the TARE key Dos Print (output once) Equivalent to the PRINT key 06 A.utopeint Refer to “16.1 1#-100/110 Electronic Printer Dol Continuous output (#) Continuous output of data in the balance at every approx. 100 ms. For less than 1200 bps it becomes approx. 150 ms. Do» ‘Output stop Autoprnt of continuous output is canceled, por Single output with stability | Printing is made once with stability information information, os Continuous output with stability | Continuous printing is made with stability information information, Q ONIOFF selection ‘Toggles between standby state and measurement state, ca) cho back ‘Characters from these command codes until delimiter are received and transmitted by every character, By use this command, message of personal ‘computer is able to print out F-10118 Characters. length is under 16- characters, including delimiter, (@) Please set ‘nore than 4800 BPS, if you get data securely -26- Displayed during weighing Displayed during UnitDisplay Setup imam rs stl in be Om leer ouion 7 une “emcient | antrese menu |cuneried | maior” lottedopey. elev of [cece doy) eer | cou or es unt [9 Inone q 7 TOT Aunt (eo Inone ko 0.007] 0.00007] [itn vk Jet [rome carat 00 quia at |pes _|rone piece counting alin vk [% [rome percentage Unt 2 Irene fozrouncey TosezTa] 0.0005 Atin vt |ox [none Jozioy ouneay ‘Toaeiso7] 0.0004 Gimme ewe Jone eertpennyweighty TEGO Tay ZLitn at Jerome jan(Gramy Tea oA Tiina ve HI fz ong Kong teal Taaeri7al 0.0008] itinvk 5 |e 2 [Singapore tael 0.0264554) 0.0005} Tint t |e iz Fraiwan tel 0266867] 00008] Bink je Malaysia tae c.026a600] 0.0008] Tal in |mom — Jnone Imomme 0.266667] 0.005 [iin at [le |none Lb%poundy 700720462] 0.00006] itn vt ti |e BA Taiwan tae! 0.0266667| 0.0001 Aint tel 123 [Taiwan tael 0.0260667] 0.0002] Taint £3 |e 12,34 [Taiwan tael 0.026667 | 0.001 T[tin st i |none |r [Sawaran 0.1250156| 0.007 20 tin vt 2 |none j2 [Kyats 0.0602409) 0.001 Zin vt 3 [none [3 [Custom 0.085738] 0.0017 “Remark No.16~21 : It can be selected in special Area only. 2 E)\SHIMADZU CORPORATION Renee gay mi we ‘ipbrs mtesei a P hea Fee nays formes somagiagcancy, mn. gene ae at gh 2a FO From es Fe sane rene eo =a m ao suzy euro Pk Gn ingen DAT Da. FR Geran ‘Rose arate far ras FRE Ruane ts

You might also like