Sgmr-sd-Arc-0078 Rev.01 - b01 l02, l05 & l07 Dry Wall Partition Layout - Aan

You might also like

You are on page 1of 7

27 SEP 2023

Refer to comments on the drawings

NU 06/10/23
B

B
CT TH
N
GENERAL NOTES:

IO
RE R
DI NO
01 02 03 04 05 06 1.THIS DRAWING IS THE COPYRIGHT OF ECC ENGINEERING
CONTRACTING Co.LLC AND MUST NOT BE RETAINED, COPIED
OR USED WITHOUT THE CONSULTANT'S AUTHORITY.

CT LA
N
IO
RE IB
DI QU
2.DO NOT SCALE FROM THE DRAWINGS.

3.ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN


METRESUNLESS NOTED OTHERWISE. ALL DIMENSIONS TO
BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

4.THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL AND CIVIL DRAWINGS AND ALL
RELEVANT SECTIONS OF THE SPECIFICATIONS.

5.LEVELS:
SITE DATUM ±0.0 = +4.48 DMD
OTB TIMBER DOOR SCHEDULE

970
DIMENSIONS (mm) KEY PLAN
CL

A 1765
(WET)
DW-01-OP 2
TYPE MARK

TD02
DESCRIPTION

SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS.
CLEAR WIDTH CLEAR HEIGHT STRUCTURAL STRUCTURAL

900 2130
WIDTH
1010
HEIGHT
2185

1165
975
100

IT
100 100 280

T LIM
PLO
T LIM
100

PLO
3330 1875 1865 4630 3290 3400 280 3400

IT
TD03 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185

785
1782
BUILDING 01 -PART 1 BUILDING 03 -PART 3
TD05 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 700 2130 810 2185
DW-02.2 B01 B03

2682
M.BEDROOM CL
(D/W) LIVING RM DW-02.8 TD06 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185

5310
CL CL
DW-02.1 (D/D) DW-02.1 DW-02.1
BATH (D/D) M.BEDROOM M.BEDROOM (D/D) TD07 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185
(D/D) BEDROOM

TD06
2300 1320 3010 1620 300 130

2555
910
BUILDING 02 -PART 2 BUILDING 04 -PART 4

4160
TD08 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 950 2130 1060 2185

4145
(D/W) (W/W)

3165
3340 280

100
B02 B04

3265
3330 720 1255 DW-02.2 DW-02.7 TD14 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 650 2200 730 2240 PLO

IT
T LIM
T LIM

PLO
IT

60
(D/D) 120 580

838
TD15 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 700 2200 780 2240
DW-02.1 DW-02.1 1865 100

1260
01 2000 1190 1300 2100 2100 1300

190
180
(D/D) TD16 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 750 2200 830 2240 CL
4205 1010 90
DW-02.1 (D/D)

620
DW-02.2 90

720
90 TD17 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 800 2200 880 2240

100

620

620
TD02 (D/D) DW-02.1 CONSULTANT STATUS:-

100

100
90 (D/W) DW-02.1 DW-02.1 DW-02.1

940
100 TD02 100

608
DW-02.7 (D/D) 2000 (D/D) (D/D) 2000

95
4005 1200 100 1865 280 650 3980 300 2190 1010 1300 1300 Approved A

1840
OTB 100
BATH
(W/W) 01
100 100

TD02
DW-02.1 CORRIDOR Approved as noted B

1200

1200

1010

1010
DW-02.2 CORRIDOR

TD06
OTB
2000

2000

910
(D/W) KITCH./DINING (D/D) 100 870 1620

2388
165 780 915 910 610 Not Approved - Resubmit C
DW-02.1

95
95

95
CORRIDOR

100

100
TD15 TD06

88
(D/D) (W/W)
TD06 TD06 Incomplete - Resubmit D

2810
BEDROOM DW-02.2 GENERAL NOTES
2300 1375 620 265 100 845 750 910
01
940 130 1260 910 870 280 870 910 1260 130

88 440 100 600


100

(D/W) DW-02.4 Information Record E

950
ONU
DW-02.3

1152
2BED ROOM-11 100

1200
BATH DW-02.2 DW-02.2 DW-02.2 DW-02.2

1235
OTB 190 DW-02.2 Structural height rule for all doors
288

1060 805 DW-02.3 BATH Structural width rule for all doors
100 (W/W) (D/W) (D/W) BATH (D/W) 190 (D/W) (D/W) REFERENCE DOCUMENT:

2010

1813

1810

1810
LAUNDRY 55+clear width+55 55+clear height

130
DB (W/W) DW-02.4
(D) 3140 1400 DW-02.4 (W/W)

120
1388

580 120
TD02

1010

DW-01-OP 1 DW-02.7 (W/W) S/N DATE DRAWING / DOCUMENT NO. REV.


TD17 LAUNDRY DW-02.2 (W/W) Structural width rule for laundry doors Structural height rule for laundry doors
1050

580
578
880
01

650
3605 400 100 WM 01
01 14-08-2023 J378- ECC- B01- SD- ARC- BW-ZZ- 10- 1119 01
(D/W) 40+clear width+40 40+clear width+40

400
90

1060
SHAFT
25 25
90

01 14-08-2023 J378- ECC- B01- SD- ARC- BW-ZZ- 10- 1120 01

100
130
84
250

280
81 300

B 3605 500 AS PER RFI 0004


883

670

DW-01-OP 1 DW-02.4 11 12 13

2066 (D) 2095 1200 100


(W/W)
1805 1710 1790
204
2B-11 TEL ELEC

2440
DW-02.8
LIVING (D/D)
KITCH./DINING
GC
3980

4070

670
2BED ROOM-9
100

10 9 8 7
203
TD08A TD08A TD08B TYPE WALL TYPE / FIRE ACOUSTIC
2B-9 DESCRIPTION WIDTH
DW-02.2 LEGEND RATING RATING
1400

(D/W) LOBBY
10480
1-LAYER OF 15MM GYPSMNA TUFF BOARD FIXING WITH
DW-01-OP 1 25MM NR NR
C
280

GYPSUM BONDING COMPOUND-METEX


This wall nib/ shelving
DW-02.6 DW-02.5
not required REVISION SCHEDULE
810

810

01
886

(D/D) (D/W) 1-LAYER OF 15MM GYPSMNA TUFF BOARD FIXED TO ONE SIDES OF
Partition wall – GA plans - General 1800
38MM MC STUDS INSTALLED 600MM CENTERS
Comments: DRESS DW-01-OP2 AND BRACED BACK TO BACKGROUND @600MM VERTICAL 30MM NR NR
2460
840

TD05

TD11
810

1.Drawings reviewed for partition wall general M.BEDROOM (D/D) BATH


(D/W) (W/W) CENTERS WITH U BRACKET
arrangement only. Comments on the typical DW-02.1 DW-02.5 DW-02.7 WM
details to be followed
OTB (D/D) (D/W)
01 25-09-2023 REVISED AS PER COMMENTS KH
BALCONY 01
810

764

DW-02.6 1100 120 580 DW-02.2 1-LAYER OF 15MM GYPSEMNA TUFF BOARD ON BOTH SIDES OF GYP 00 04-08-2023 ISSUED FOR APPROVAL BS
2.Contractor to ensure structural integrity of the (D/D) 130 1514 130
102MM NR 45dB
190
1590

DW-02.8 DW-02.1 70MM X 0.50MM WALL STUD, SPACED @600MM CENTERS WITH ONE Rev Date Description App. By
partition walls – Subject to relevant structural 46 01 LIFT 3(FIRE LIFT) LIFT 2 ROWS OF GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3
1796 814 910 144 2370 100 1400 305
calculation approvals. 9 8 7 6 5 4 3 2 1 Client
859

(D/D) STAIR 02
3.As per the discussion for partition walls in TD03
STORAGE
DW-02.1 1-LAYER OF 15MM GYPSEMNA REGULAR GYPSUM BOARD ON
79
190

1900

1900

thickness 102mm & 132mm to be centralized OTB 910 202 STAIR 02 ONE SIDES &1-LAYER OF 15MM GYPSEMNA REGULAR GYPSUM
840 2506 714 100 STORAGE
TD05

between the rooms. 3B-4


810

OTB DW-02.2 BOARD & 15MM THK MOISTURE RESISTANT GYPSUM BOARD 102MM NR 45dB
D
4.For overall dimension of the areas – strictly to 130 2370 100 285 830 285 305
OTHER SIDES OF GYP 72MM X0.50MM ALL STUDS SPACED @ 600MM
205 231

60 219

(D/D)
follow IFC GA layouts. Contractor to ensure
2000

TD17
130

100

DW-02.1 100 CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM THK
2330

Bath room fitting allocation within the toilets are 2370 1415
10 11 12 13 14 15 16 17 18 12Kg-M3
as per ID drawings/ approved shop drawings for BATH (W/W) DW-02.5
810

201 MINA RASHID PROPERTIES LLC


1230

(D/W)
TD05

DW-02.7 (D/W)
SD01

enlarged toilet layouts. Contractor to ensure BEDROOM 1 DW-02.2 2B-7


100

1100
1-LAYER OF 15MM GYPSEMNA TUFF MOLD &MOISTURE
330

provide required spacing between fittings Design & Supervision Consultant


50
220

1460 840 2600 620 SHAFT RESISTANT BOARD ON BOTH SIDES OF GYP 70MM X 0.50MM WALL
2740
180

coordinate with approved bathroom accessories (W/W) DW-02.3 102MM NR 45dB


STUD, SPACED @600MM CENTERS WITH ONE ROWS OF GYPSEMNA
45

DW-02.5 2370 BATH

1265
1215

TD03

sizes and any variation to be highlighted /will be 2BED ROOM-07 1165 DW-02.7
910

910

1825

(D/W) SHAFT AUDIO INSUL 50MM THK 12Kg/M3


1200

1200

01
contractor's responsibility. 4060
(D/D) LOBBY
POWDER ROOM (W/W)
85

5.All MEP pipes / electrical conduits fixing (D/W)

2695
(D/W) (D/W) M.BATH
130

330

DW-02.1 1-LAYER OF 15MM GYPSEMNA TUFFMOLD AND MOISTURE

2595

2595
130 796 810 764 100
115

DW-02.2 DW-02.3 DW-02.3 DW-02.2 DW-02.2


locations to be fully coordinated with MEP TD05
(W/W) RESISTANT BOARD ON BOTH SIDES OF GYP 100MM
1115 2600 1515
TD03

Contractor. Fixing heights to be coordinated KITCHEN/DINING X0.50MM WALL STUD, SPACED @600MM CENTERS WITH
910

910

1430

1430
DW-02.6
1215

ENTRY LD
(D/D) DW-02.2 DW-02.2 2695 DW-02.4 132MM NR 46dB
with approved typical wiring accessories
1100

1100

CORRIDOR 100 166 ONE ROWS OF GYPSEMNA AUDIO INSUL 50MM THK Main Contractor
(D/W) (D/W) 2050 4004 675 100 860 1815 972 813
190

65 160
100

elevation drawings / bathroom typical drawings 910 1686 880 12Kg/M3


390

100

100 TD06

100
TD16 TD06
100

6.DB and ONU cabinet wall arrangement and

95
TD03 TD17
2300 2600 620 790 830 910 100 1777 910 813
100

100
01 1-LAYER OF 15MM GYPSEMNA GYPSUM BOARD ON ONE SIDES

J378-ECC-AG-B01-SD-ARC-DRW-L02-10-3004
cabinet fixation heights to be comply with (D/W) 100 AS PER RFI 0059 175 106
OTB (D/W)
48 1512 1000
(D/W) &1-LAYER OF 15MM GYPSEMNA TUFF BOARD & 15MM THK
850

850

850

TD02
LD
1200

1010

1010
BEDROOM 2 DW-02.2 DW-02.3 DRESS
authority requirements. Partitioning to DB DW-02.2 DW-02.1
(W/W) DW-02.2 CORRIDOR GYPSEMNA TUFF MOISTURE RESISTANT GYPSUM BOARD
2000

1850
(D/D) 258 100 100
and ONU cabinet locations to be provided 2358 1215 2185
1800

BATH DW-02.2 810 100 95


DW-02.5 OTHER SIDES OF GYP 100MM X 0.50MM WALL STUDS SPACED @ 132MM NR 46dB
(D/D)
100
100

TD02
with fire rated gypsum boards as per 100
2500 (D/W)
01
600MM CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM
7050
950

58 1010 58
1050

400 3660 DW-02.1

620
authority requirements.
650

2BED ROOM-7 DW-02.1 01


810

THK 12Kg-M3
100

01 01
7.All load bearing accessories fixing location on (D/D)

100
2100 1125 250 1215 2285
the partition walls to be encountered and 1200 1400 100 25 25 1-LAYER OF 15MM GYPSEMNA TUFF BOARD ON
650

FOR CONTINUATION REFER TO DWG-NO :


DW-02.1 (D/D) DW-02.8
provide with extra support backing panels/ (W/D) DW-02.6 BOTH SIDES OF GYP 100MM X 0.50MM WALL STUD,
(D/D) DW-02.1
structural brazing. – Subject to relevant 825 2467 2633 620
DW-02.1
(D/D) SPACED @600MM CENTERS WITH ONE ROWS OF 132MM NR 46dB
3710

structural calculation approvals. 100 GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3
3965

8.All partition wall dimensions to be coordinated LIVING LIVING ROOM


3085

3085

1-LAYER OF 15MM GYPSEMNA TUFFMOLD AND MOISTURE

3315
BEDROOM M.BEDROOM 150MM
3155

3155

with as build block wall / shear wall dimensions, 1885 3190


RESISTANT BOARD ON BOTH SIDES OF GYP 50MM X
Sub Contractor
4100

any discrepancies of inner wall dimension to be (DRY) (DRY) DW-02.7 0.50MM WALL STUD, SPACED @600MM CENTERS WITH TO NR 46dB
highlighted in wall marking inspections. 100
DW-01-OP 1 DW-01-OP 1
ONE ROWS OF GYPSEMNA AUDIO INSUL 50MM THK 300MM
KITCHEN/DINING ROOM 5075 3325 300 3500 TEL : +971 4 2675229
9.Contractor to ensure all door opening sizes to 12Kg/M3 FAX : + 971 4 267 6629

door details. E
be coordinated with approved shop drawings for
1-LAYER OF 15MM GYPSEMNA TUFF BOARD BOARD ON 150MM
PO.BOX : 99525 , DUBAI - UAE
E-MAIL : INFO@ALAGHAGROUP.COM
1070

10.Contractor to ensure to follow approved WWW.ALAGHAGROUP.COM


1065

9260
BOTH SIDES OF GYP 50MM X 0.50MM WALL STUD, SPACED
system/ materials for sub-frame and Gypsum ? DW-02.8 TO NR 46dB AL AGHA GROUP
@600MM CENTERS WITH ONE ROWS OF
Boarding/ taping materials.
OTB OTB
BALCONY
GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3 300MM
Project Title
1-LAYER OF 15MM GYPSEMNA GYPSUM BOARD ON ONE SIDES
? ?
OTB &1-LAYER OF 15MM GYPSEMNA TUFF BOARD & 15MM THK 150MM MIXED USE RESIDENTIAL BUILDING:
DW-02.9 GYPSEMNA TUFF MOISTURE RESISTANT GYPSUM BOARD TO NR 46dB BLDG 1: B01+GFL+15, BLDG 2: B01+GFL+L06,
MATCH LINE - A

OTHER SIDES OF GYP 50MM X 0.50MM WALL STUDS SPACED @


600MM CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM
300MM BLDG 3:B01-GFL-10, BLDG 4:B01+GFL+L05
THK 12Kg-M3
Drawing Title

BUILDING-1
LEVEL02,05,07
DRY WALL PARTITION LAYOUT PART-1
LEVEL 02,05,07 DRYWALL PARTITION LAYOUT - B01 - PART - 01 06.10.23
Drawing reviewed for master bathroom wall nib addition only . Ensure previous NU
Scale Sheet Size Date Drawn by Checked by Approved by
1:125 A1 25-09-2023 SF SH KH
revision comments encountered in this submissions Drawing Number
Revision
J378-ECC-AG-B01-SD-ARC-DRW-L02-10-3003 01
CT TH
N
GENERAL NOTES:

IO
RE R
D I NO
1.THIS DRAWING IS THE COPYRIGHT OF ECC ENGINEERING

06 07 08 09 10 11 CONTRACTING Co.LLC AND MUST NOT BE RETAINED, COPIED


OR USED WITHOUT THE CONSULTANT'S AUTHORITY.

CT LA
N
IO
RE IB
DI QU
2.DO NOT SCALE FROM THE DRAWINGS.

3.ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN


METRESUNLESS NOTED OTHERWISE. ALL DIMENSIONS TO
BE VERIFIED ON SITE & APPROVED BY THE ENGINEER.

4.THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH


J378-ECC-AG-B01-SD-ARC-DRW-L02-10-3003 OTHER RELEVANT ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL AND CIVIL DRAWINGS AND ALL
RELEVANT SECTIONS OF THE SPECIFICATIONS.

5.LEVELS:
SITE DATUM ±0.0 = +4.48 DMD

OTB OTB KEY PLAN


FOR CONTINUATION REFER TO DWG-NO :

4630 CL

100
2155
100 100

IT
PLO

T LIM
T LIM

PLO
IT

1765 1875 100 3330 TIMBER DOOR SCHEDULE

975
100 100
(D/D) DIMENSIONS (mm) BUILDING 01 -PART 1 BUILDING 03 -PART 3
3400 280 3400 3285 DW-01-OP 2

785
DW-02.1 B01 B03

1782

1782
(WET) TYPE MARK DESCRIPTION CLEAR WIDTH CLEAR HEIGHT STRUCTURAL STRUCTURAL CL
(D/W) WIDTH HEIGHT CL CL

2583
BATH DW-02.2

2682
(D/D) LIVING RM TD02 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 900 2130 1010 2185

5320
DW-02.1 DW-02.8 920 2300
(D/D) TD03 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185
M.BEDROOM M.BEDROOM BEDROOM BUILDING 02 -PART 2 BUILDING 04 -PART 4

3942
(D/D) DW-02.1

TD06
2785 505 1170 3400 M.BEDROOM

2555
B02 B04

910
TD05 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 700 2130 810 2185

4160
4155

620 IT

PLO
60
T LIM

T LIM
100
PLO

IT
(W/W)

3165
3340 280 TD06 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185

3265
(D/D) DW-02.7 DW-02.2
60 720 3330
(D/W) (D/D) TD07 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 800 2130 910 2185

838
DW-02.1 580 120 1165 CL
100

1260
1250
1190 1300 2100 2100 1300 1190 2000 300 DW-02.1

190

180
01
TD08 SINGLE SWING TIMBER DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. FIRE RATING AS PER THE FLS DRAWINGS. 950 2130 1060 2185
(D/D) 94 1010 4201 CONSULTANT STATUS:-
DW-02.1 (D/D) 100 90 90

100
DW-02.1 TD14 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 650 2200 730 2240

620
90
720

1010

610 100

100
620

620
(D/D) DW-02.1 TD02
DW-02.1 DW-02.1 DW-02.1 650 Approved A

100

100

942
TD02 100 TD02 1865 100 1200 4005
(D/D) 2000 (D/D) (D/D) 2000 TD15 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 700 2200 780 2240
95

95
1010 1300 1300 100 1010 2190 300 (D/D) B
100 Approved as noted
1840

01
100 100
01 DW-02.7
DW-02.1 OTB TD16 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 750 2200 830 2240
TD02

CORRIDOR C

TD02
(W/W) Not Approved - Resubmit

1010

1010

1200

1200
1010

CORRIDOR DW-02.2
OTB

2000
2800
(D/D)

910
TD06
100 870 1620 100 595 900 780 (D/W) TD17 DOUBLE TIMBER CUPBOARD DOOR, SIDE HINGED WITH ALL THE REQUIRED IRONMONGERY AS PER THE SCHEDULE. FINISHES AS PER THE ID DRAWINGS. 800 2200 880 2240

2390
610 KITCH./DINING BATH DW-02.1 Incomplete - Resubmit D

100
95
CORRIDOR
95

95
100

100

100

100
TD06 BEDROOM

88
TD06 TD15
TD06
01 2BED ROOM-2A (W/W) Information Record E

3483
01 100 DW-02.2
130 130 620

3210
940 1260 910 870 280 870 910 1260 940 910 750 845

100
88 440 100 600
DW-02.4 DW-02.2

948
ONU (D/W) REFERENCE DOCUMENT:

1215
1315
1200
DW-02.2 DW-02.2 DW-02.2
1235

1235

DW-02.2 DW-02.2 190 DW-02.2 DW-02.2 (D/W)

288
BATH 100
BATH OTB

130
(D/W) (D/W) (D/W) 190 (D/W) (D/W) (D/W) (D/W) 265 1400 2740 400
1810

1810

1813
BATH

130
DW-02.4 100 DB S/N DATE DRAWING / DOCUMENT NO. REV.
DW-02.4 (W/W) GENERAL NOTES
120

TD02
(D/D)
580 120

1010
DW-02.7 (W/W) DW-02.3 01 14-08-2023 J378- ECC- B01- SD- ARC- BW-ZZ- 10- 1119 01
(W/W) DW-02.8

1050

1050
LAUNDRY
580
578

578

14-08-2023

TD15
4005

780
DW-02.2 02 J378- ECC- B01- SD- ARC- BW-ZZ- 10- 1120 01

695
01

650
01
(W/W) WM Structural width rule for all doors Structural height rule for all doors

88
88
(D/W) SHAFT 55+clear height
100

55+clear width+55

130

130

300

300
371
1060
B

913
(D/W) Structural width rule for laundry doors Structural height rule for laundry doors

650
11 12 13 14 15 16 17 18 19 20 DW-02.4 4105 40+clear width+40 40+clear width+40
130 DW-02.2
205 (W/W)
01
1380 280 2455 1060 1200 693 3412
2B-2A
TEL ELEC 100 AS PER RFI 0004

2440
(D/W)
STAIR 01 DW-02.2 LIVING

3925
UP

KITCH./DINING 2-BED ROOM-1

100
10 9 8 7 6 5 4 3 2 1
TYPE WALL TYPE / DESCRIPTION FIRE ACOUSTIC
WIDTH
TD08A TD08B 1518 662 LEGEND RATING RATING
206 LOBBY
2B-1
1-LAYER OF 15MM GYPSMNA TUFF BOARD FIXING WITH
DW-01-OP 1 25MM NR NR
GYPSUM BONDING COMPOUND-METEX
C REVISION SCHEDULE
400
(D/W) 1-LAYER OF 15MM GYPSMNA TUFF BOARD FIXED TO ONE SIDES OF

650
1130 DW-02.2
01 3970 2300 38MM MC STUDS INSTALLED 600MM CENTERS
3550 100 5210 DW-01-OP2 AND BRACED BACK TO BACKGROUND @600MM VERTICAL 30MM NR NR
Partition wall – GA plans - General Comments: CENTERS WITH U BRACKET
2130

LIVING ROOM 1.Drawings reviewed for partition wall general


01 25-09-2023 REVISED AS PER COMMENTS KH
OTB
arrangement only. Comments on the typical details to 1-LAYER OF 15MM GYPSEMNA TUFF BOARD ON BOTH SIDES OF GYP 00 04-08-2023 ISSUED FOR APPROVAL BS
1-BED ROOM-2

4140
650
01 KITCHEN/DINING be followed DW-02.1 70MM X 0.50MM WALL STUD, SPACED @600MM CENTERS WITH ONE 102MM NR 45dB Rev Date Description App. By

3410
100

2.Contractor to ensure structural integrity of the ROWS OF GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3
partition walls – Subject to relevant structural
LIFT 3(FIRE LIFT) LIFT 2 LIFT 1 Client
5 4 3 2 1
DW-02.2 (D/D)
STAIR 02 calculation approvals.
207 (D/W) DW-02.8 1-LAYER OF 15MM GYPSEMNA REGULAR GYPSUM BOARD ON
1450

1450

DW-02.6 (D/D) 3.As per the discussion for partition walls in thickness
1B-2 ONE SIDES &1-LAYER OF 15MM GYPSEMNA REGULAR GYPSUM
1320 1200 (D/D) 4195 DW-02.1 2530 OTB
102mm & 132mm to be centralized between the
90 600 100 440 90
DW-02.2 BOARD & 15MM THK MOISTURE RESISTANT GYPSUM BOARD 102MM NR 45dB
100

OTB
rooms.
D OTHER SIDES OF GYP 72MM X0.50MM ALL STUDS SPACED @ 600MM
265

DB
4.For overall dimension of the areas – strictly to
100

ONU
4065
410

(W/W) CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM THK
45

01
1220
100

DW-02.3 follow IFC GA layouts. Contractor to ensure Bath 12Kg-M3


910

1230

(D/D)
TD03
TD17

13 14 15 16 17 18
LD
100 965

880

DW-02.6 room fitting allocation within the toilets are as per ID MINA RASHID PROPERTIES LLC
drawings/ approved shop drawings for enlarged toilet
40

1-LAYER OF 15MM GYPSEMNA TUFF MOLD &MOISTURE


100
40

222

95
208 TD06
100

130 Design & Supervision Consultant


50

2B-12 1485 940 620 layouts. Contractor to ensure provide required RESISTANT BOARD ON BOTH SIDES OF GYP 70MM X 0.50MM WALL
SHAFT DW-02.3 102MM NR 45dB
3330

(W/W) spacing between fittings coordinate with approved STUD, SPACED @600MM CENTERS WITH ONE ROWS OF GYPSEMNA
45

DW-02.3 DW-02.1 BEDROOM


BATH bathroom accessories sizes and any variation to be AUDIO INSUL 50MM THK 12Kg/M3
1265

(W/W) (D/W)
1165

DW-02.7 (D/D)
SHAFT
2000

2000

DW-02.5 highlighted /will be contractor's responsibility.


(W/W) (D/W) KITCH/DINING BATH 5.All MEP pipes / electrical conduits fixing locations 1-LAYER OF 15MM GYPSEMNA TUFFMOLD AND MOISTURE
2695

(D/W) (D/W) M.BATH


2595

2595

130
DW-02.2 DW-02.3 DW-02.3 DW-02.2 DW-02.2 2520 4065 to be fully coordinated with MEP Contractor. Fixing RESISTANT BOARD ON BOTH SIDES OF GYP 100MM
2BED ROOM-12
3390

(W/W) X0.50MM WALL STUD, SPACED @600MM CENTERS WITH


heights to be coordinated with approved typical wiring DW-02.4 132MM NR 46dB
1430

1430

LD (D/W)
95 280

2695
100 accessories elevation drawings / bathroom typical ONE ROWS OF GYPSEMNA AUDIO INSUL 50MM THK Main Contractor
675 100 860 100 1815 166 972 813 280 DW-02.2 2530 1975 3400 1605 1880 1710 12Kg/M3
507

507

(D/D)
01
130 DW-02.2
drawings
OTB
(D/D)
100

TD06
100

TD16 TD06
1010

1200

6.DB and ONU cabinet wall arrangement and


100

DW-02.8 1-LAYER OF 15MM GYPSEMNA GYPSUM BOARD ON ONE SIDES


95

CORR.
TD02

790 830 910 100 1777 910 813 01 DW-02.1 (D/W) 130
01 100
175 106 650 1880 1975 850 810 605 cabinet fixation heights to be comply with &1-LAYER OF 15MM GYPSEMNA TUFF BOARD & 15MM THK
910

910

670
TD06

AS PER RFI 0059 315 440 600


100

M.BATH
TD02
1200

1010

1010

95

DRESS authority requirements. Partitioning to DB and GYPSEMNA TUFF MOISTURE RESISTANT GYPSUM BOARD
108

1590

CORRIDOR (D/D) DB ONU


90

01
DW-02.5 NR 46dB
1850

615

ONU cabinet locations to be provided with fire 132MM


175

2358 258 100 1215 100 2185 (D/D) OTHER SIDES OF GYP 100MM X 0.50MM WALL STUDS SPACED @
DW-02.8 DW-02.2
720

TD17
620

880
895

895

723
810 100 95

(D/D) WM
LAUND.
TD02

rated gypsum boards as per authority


1115

DW-02.1 (D/W) 600MM CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM
100
100

TD02
1010

01
58 1010 58 DW-02.1 310 1995 1215 1000 700
requirements.
620

1523

THK 12Kg-M3
650

DW-02.1
180

01
100
810

100

343

01 100
(D/D) 01
7.All load bearing accessories fixing location on the
100

TD06 130 DW-02.1 1-LAYER OF 15MM GYPSEMNA TUFF BOARD ON


620

2100 1125 250 1215 2285 41 910 849 DW-02.7


100 25 25 01
(D/D) partition walls to be encountered and provide with
LIVING ROOM DW-02.6 BOTH SIDES OF GYP 100MM X 0.50MM WALL STUD,
DW-02.8 3315
100
1800
DW-02.2 1080 1485 (W/W)1240 315 745 extra support backing panels/ structural brazing. – NR 46dB
132MM
4080

(D/D) DW-02.1 (D/W) 100 SPACED @600MM CENTERS WITH ONE ROWS OF
Subject to relevant structural calculation approvals.
4395

(D/D)
2400

BEDROOM GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3


3710

BATH 8.All partition wall dimensions to be coordinated with


3965

2765

2750

as build block wall / shear wall dimensions, any 1-LAYER OF 15MM GYPSEMNA TUFFMOLD AND MOISTURE 150MM
3315

BEDROOM M.BEDROOM Sub Contractor


4955
3155

3155

2810 505 DW-02.2 DW-02.5 discrepancies of inner wall dimension to be RESISTANT BOARD ON BOTH SIDES OF GYP 50MM X
(D/W) (D/W) M.BEDROOM OTB TO NR 46dB
(DRY) (DRY) highlighted in wall marking inspections. DW-02.7 0.50MM WALL STUD, SPACED @600MM CENTERS WITH
100 DW-01-OP 1 DW-01-OP 1 9.Contractor to ensure all door opening sizes to be ONE ROWS OF GYPSEMNA AUDIO INSUL 50MM THK 300MM TEL : +971 4 2675229
3325 300 3500 280 2530 1975 290 coordinated
OTB with approved shop drawings for door 12Kg/M3 FAX : + 971 4 267 6629
details.
E PO.BOX : 99525 , DUBAI - UAE
2020

10.Contractor to ensure to follow approved system/ E-MAIL : INFO@ALAGHAGROUP.COM


1-LAYER OF 15MM GYPSEMNA TUFF BOARD BOARD ON 150MM
1460

2615 1240 WWW.ALAGHAGROUP.COM


materials for sub-frame and Gypsum Boarding/
1075

BOTH SIDES OF GYP 50MM X 0.50MM WALL STUD, SPACED


OTB OTB taping materials. DW-02.8 TO NR 46dB AL AGHA GROUP
@600MM CENTERS WITH ONE ROWS OF
BALCONY GYPSEMNA AUDIO INSUL 50MM THK 12Kg/M3 300MM
OTB OTB
Project Title
1-LAYER OF 15MM GYPSEMNA GYPSUM BOARD ON ONE SIDES
&1-LAYER OF 15MM GYPSEMNA TUFF BOARD & 15MM THK 150MM MIXED USE RESIDENTIAL BUILDING:
DW-02.9 GYPSEMNA TUFF MOISTURE RESISTANT GYPSUM BOARD TO NR 46dB BLDG 1: B01+GFL+15, BLDG 2: B01+GFL+L06,
MATCH LINE - A

OTHER SIDES OF GYP 50MM X 0.50MM WALL STUDS SPACED @


600MM CENTERS WITH ONE ROWS GYPSEMNA AUDIO INSUL 50MM
300MM BLDG 3:B01-GFL-10, BLDG 4:B01+GFL+L05
THK 12Kg-M3
Drawing Title
BUILDING-1
LEVEL02,05,07
Drawing reviewed for master bathroom wall nib addition only . Ensure previous 06.10.23 NU DRY WALL PARTITION LAYOUT PART-2
LEVEL 02,05,07 DRYWALL PARTITION LAYOUT - B01 - PART - 02
revision comments encountered in this submissions Scale Sheet Size Date Drawn by Checked by Approved by
1:125 A1 25-09-2023 SF SH KH
Drawing Number
Revision
J378-ECC-AG-B01-SD-ARC-DRW-L02-10-3004 01

You might also like