Model Selector

03/26/24
Date
www.rulmecacorp.com
www.rulmeca.com
© Copyright - Rulmeca Group

Telephone Telefax e-mail

Project Name Conveyor Reference

REQUIRED POWER: 296.8 kW


Select Model
BELT PULL SUMMARY: Force (N)
Standard Loading Belt Pull 20 197
800M
Extra pull for Hopper (if any) 74 559 Check Radial Load (to prevent
Extra pull for Slider Bed (if any) internal damage to pulley) Force (N)
Extra pull for Diverter or Tripper (if any) Maximum Allowable Radial Load 73 600
TOTAL Required Belt Pull (Te): 94 755 Estimated Maximum Radial Load 189 511
Error: Selected model is incorrect.
Choose stronger or larger model to handle estimated radial load.
Check Pulley Diameter
RECOMMENDED OPTIONS (if any): (to prevent belt damage.)
1. Mechanical Backstop Minimum Acceptable Diameter is 610 mm
Selected Diameter is 800 mm
Selected diameter is appropriate for specified belt.
SPECIAL NOTES (if any): (This calculation does not check pulley/belt traction.)

Check Belt Tension Force (N)


Maximum Belt Tension (T1) 142 133
Go to Design Parameters Allowable Belt Tension 93 128
RECOMMENDED "SINGLE DRIVE" MOTORIZED PULLEY: Choose stronger belt to handle estimated maximum belt tension.
Power: Not Avail. kW Models Available:
Belt Speed: 3.15 m/s #N/A
Face Width: 1250 mm

RECOMMENDED "DUAL DRIVE" MOTORIZED PULLEY:


Power: Not Avail. kW/ea Models Available:
Belt Speed: 3.15 m/s #N/A
Face Width: 1250 mm