If you have technical problems, first contact your installer. The following information is required in
order to provide you with the necessary assistance:
PV Inverter
SUNNY BOY 2500/3000
User Manual
Installer contact
SB25_30-BA-BEN115030 | IMEN-SB25_30 | Version 3.0 EN
You can operate the display by tapping it (see section entitled "Operation").
Glossary
Symbols on the Type Label
Beware of hazardous voltage. AC
The inverter operates at high voltages. All electrical work Abbreviation for "Alternating Current".
on the inverter must be carried out by electrically qualified persons DC
only. Abbreviation for "Direct Current".
Beware of hot surface. Derating
The inverter can become hot during operation. Avoid contact during operation. Controlled reduction of power due to excessive temperature or the grid operator's specifications, e.g.
using the Power Reducer Box.
The inverter is protected against dust intrusion and water jets from any angle.
NOTICE! LEDs
Overvoltage in the inverter if yellow LED flashes 4 times.
Destruction of the inverter.
Operation
• Inform your installer immediately if the yellow LED should
start flashing and the following display message appears. Ground fault or varistor defective
Disturbance
Pac Generated AC power Disturbance, Disturbance. This message appears for safety reasons and prevents the inverter
disturbance from connecting to the grid. Inform your installer.
Riso Insulation resistance of the PV plant prior to the grid connection
Stop Operation interrupted.
Serial Number Inverter serial number
V-Const Constant voltage mode.
Mode Display of the current operating state
waiting The conditions for connecting are not (yet) fulfilled.
Vac Line voltage
Vpv PV input voltage
Vpv-Setpoint PV setpoint voltage