You are on page 1of 160

Design Guide

REVISED 10/2023
Design Guide

Features and specifications are subject to change at any


time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
Throughout this guide, dimensions may vary by ± 1/8" (3).
Dimensions in parentheses are millimeters unless otherwise
specified.

2 | Wolf Customer Care 800.222.7820


Contents

Contents
4 M Series Ovens
16 E Series Ovens
30 Convection Steam Ovens
38 Speed Ovens
44 Microwave Ovens
58 Warming Drawers
64 Induction/Electric Cooktops
72 Gas Cooktops
78 Module Cooktops
88 Coffee System
94 Cup Warming Drawer
98 Vacuum Seal Drawer
104 Dual Fuel Ranges
108 Gas Ranges
112 Induction Ranges
116 Sealed Burner Rangetops
120 Outdoor Grills/Modules
132 Cooktop Ventilation Hoods
142 Downdraft Ventilation
148 Pro Ventilation Hoods
158 Wolf Warranty

wolfappliance.com | 3
M Series Ovens

M Series Built-In Ovens


MODELS
TRANSITIONAL

SO3050TM/S/TH

DO3050TM/S/TH

PROFESSIONAL

UPPER OVEN LOWER OVEN

SO3050PM/S/PH

DO3050PM/S/PH

CONTEMPORARY

SO3050CM/S SO3050CM/B

DO3050CM/S DO3050CM/B

4 | Wolf Customer Care 800.222.7820


M Series Ovens

30" M Series Built-In Ovens


TRANSITIONAL SINGLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 2 1/2" 23" (584)


(65) BEHIND FRAME OPEN OVEN DOOR 21 3/8"
(543)

TRANSITIONAL DOUBLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 2 1/2" 23" (584)


(65) BEHIND FRAME

wolfappliance.com | 5
M Series Ovens

30" M Series Built-In Ovens


PROFESSIONAL SINGLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 3 1/4" 23" (584)


(83) BEHIND FRAME OPEN OVEN DOOR 21 3/8"
(543)

PROFESSIONAL DOUBLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 3 1/4" 23" (584)


(83) BEHIND FRAME

6 | Wolf Customer Care 800.222.7820


M Series Ovens

30" M Series Built-In Ovens


CONTEMPORARY STAINLESS STEEL SINGLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 23" (584)


BEHIND FRAME OPEN OVEN DOOR 21 3/8"
(543)

CONTEMPORARY STAINLESS STEEL DOUBLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 23" (584)


BEHIND FRAME

wolfappliance.com | 7
M Series Ovens

30" M Series Built-In Ovens


CONTEMPORARY BLACK GLASS SINGLE OVEN

1" 8 5/8" 1 7/8"


(25) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 23" (584)


BEHIND FRAME OPEN OVEN DOOR 21 3/8"
(543)

CONTEMPORARY BLACK GLASS DOUBLE OVEN

1" 8 5/8" 1 7/8"


(25) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 23" (584)


BEHIND FRAME

8 | Wolf Customer Care 800.222.7820


M Series Ovens

Planning Information
The M Series Oven can be installed in a standard or flush ELECTRICAL REQUIREMENTS
inset application. If a cooktop is installed above an oven, a
Installation must comply with all applicable electrical codes.
minimum of 1/4" (6) is required between the units. The loca-
Locate the electrical supply flush with the back wall and
tion of the electrical supply within the oven opening may
within the shaded area shown in the illustrations on the
require additional cabinet depth.
following pages. For ease of installation, the electrical
Finish the edges of the opening. They may be visible when supply for the oven can be placed in an adjacent cabinet
the door is open. within reach of the conduit.
For standard installations, the face trim will overlap stiles Performance may be compromised if the electrical supply
and rails. Refer to the chart below. is less than 240 volts.
For flush inset installations, a minimum 1/8" (3) reveal is The oven is supplied with a conduit consisting of two
required on all sides. To ensure consistent reveals, each insulated hot lead conductors and a bare ground con-
corner of the opening must be exactly 90°. ductor. The wiring diagram covering the control circuit is
provided with the oven.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN ELECTRICAL REQUIREMENTS—SINGLE OVEN
Single Oven 250 lb (115 kg) Electrical Supply grounded, 240/208 VAC, 60 Hz
Double Oven 400 lb (181 kg)
Service 30 amp dedicated circuit
TRIM OVERLAP
Conduit 4' (1.2 m)
Top 1" (25)
Bottom 0" (0) Total Amps 22
Sides 11/16" (18)
Max Connected Load 5.4 kW

DUAL INSTALLATION ELECTRICAL REQUIREMENTS­—DOUBLE OVEN

Two M Series Single Ovens can be installed side by side in a Electrical Supply grounded, 240/208 VAC, 60 Hz
standard or flush inset application. A dual installation kit is Service 50 amp dedicated circuit
required. To maintain appropriate airflow, the ovens must
Conduit 5' (1.5 m)
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airflow and Total Amps 45
is not recommended. Refer to the illustrations on pages Max Connected Load 10.8 kW
14–15.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.

wolfappliance.com | 9
M Series Ovens

30" M Series Single Oven


STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E
(127)
4"
(102)
27 1/2"
(699) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

10 | Wolf Customer Care 800.222.7820


M Series Ovens

30" M Series Single Oven


FLUSH INSET INSTALLATION

7/8" (22) 24" (610)


OR FLUSH INSET
1" (25)** DEPTH
FINISHED
CLEATS*

TOP VIEW

30 1/8" (765)
FLUSH INSET WIDTH***

5"
11/8" (29) (127) E
4"
(102)
28 3/4"
(730)
FLUSH INSET
HEIGHT***

13/16" (21) E

1/8" (3)
E

SIDE VIEW FRONT VIEW

*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

wolfappliance.com | 11
M Series Ovens

30" M Series Double Oven


STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E
(127)
4"
(102)

49 7/8"
(1267) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT

E
17" (432)
TYPICAL

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

12 | Wolf Customer Care 800.222.7820


M Series Ovens

30" M Series Double Oven


FLUSH INSET INSTALLATION

7/8" (22) 24" (610)


OR FLUSH INSET
1" (25)** DEPTH
FINISHED
CLEATS*

TOP VIEW

30 1/8" (765)
FLUSH INSET WIDTH***

5"
11/8" (29) (127) E
4"
(102)

51 1/8"
(1299)
FLUSH INSET
HEIGHT***

13/16" (21) E

1/8" (3)
E
17" (432)
TYPICAL

SIDE VIEW FRONT VIEW

*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

wolfappliance.com | 13
M Series Ovens

30" M Series Single Oven


DUAL STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E 5" E
(127) (127)
4" 4"
(102) (102)
27 1/2"
(699)
OPENING 58 1/2" (1486)
HEIGHT OPENING WIDTH

E E

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

14 | Wolf Customer Care 800.222.7820


M Series Ovens

30" M Series Single Oven


DUAL FLUSH INSET INSTALLATION

7/8" (22) 24" (610)


OR FLUSH INSET
1" (25)** DEPTH
FINISHED
CLEATS*

TOP VIEW

60 1/8" (1527)
FLUSH INSET WIDTH***

5" E 5" E
11/8" (29) (127) (127)
4" 4"
(102) (102)
28 3/4"
(730)
FLUSH INSET
HEIGHT***

13/16" (21)

1/8" (3)
E E

SIDE VIEW FRONT VIEW

*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

wolfappliance.com | 15
E Series Ovens

E Series Built-In Ovens


MODELS
TRANSITIONAL

SO24TE/S/TH
SO3050TE/S/TH

DO3050TE/S/TH

PROFESSIONAL

SO3050PE/S/PH

DO3050PE/S/PH

16 | Wolf Customer Care 800.222.7820


E Series Ovens

24" E Series Built-In Oven


TRANSITIONAL SINGLE OVEN

7/8" 22"
(22) (559)

23 1/2" 23 1/4"
(597) (591)

23 1/2" 2 1/2" 21 1/2" (546)


(597) (64) BEHIND FRAME
18 1/8"
OPEN OVEN DOOR (460)

wolfappliance.com | 17
E Series Ovens

30" E Series Built-In Ovens


TRANSITIONAL SINGLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 2 1/2" 23" (584)


(65) BEHIND FRAME
OPEN OVEN DOOR 21 3/8"
(543)

TRANSITIONAL DOUBLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 2 1/2" 23" (584)


(65) BEHIND FRAME

18 | Wolf Customer Care 800.222.7820


E Series Ovens

30" E Series Built-In Ovens


PROFESSIONAL SINGLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)

28 1/2"
(724)

29 7/8" (759) 3 3/8" 23" (584)


(86) BEHIND FRAME
OPEN OVEN DOOR 21 3/8"
(543)

PROFESSIONAL DOUBLE OVEN

7/8" 8 5/8" 1 7/8"


(22) (218) (46)

2" (51)
1 3/8" (36)
CONDUIT
CHANNEL

28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)

OPEN OVEN DOOR 21 3/8"


(543)

29 7/8" (759) 3 3/8" 23" (584)


(86) BEHIND FRAME

wolfappliance.com | 19
E Series Ovens

Planning Information
The E Series Oven can be installed in a standard or flush DUAL INSTALLATION
inset application. If a cooktop is installed above an oven, a
Two 30" E Series Single Ovens can be installed side by
minimum of 1/4" (6) is required between the units. The loca-
side in a standard or flush inset application. A dual instal-
tion of the electrical supply within the oven opening may
lation kit is required. To maintain appropriate airflow, the
require additional cabinet depth.
ovens must be installed into one opening. Any cosmetic or
Finish the edges of the opening. They may be visible when structural material placed between the ovens will impede
the door is open. airflow and is not recommended. Refer to the illustrations
on the following pages.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below. The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
For flush inset installations, a minimum 1/8" (3) reveal is
showroom section of our website, wolfappliance.com.
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Oven 150 lb (68 kg)
30" Single Oven 250 lb (113 kg)
30" Double Oven 400 lb (181 kg)

TRIM OVERLAP 24" OVEN 30" OVEN


Top 1/4" (6) 1" (25)
Bottom 0" (0) 0" (0)
Sides 11/16" (17) 11/16" (17)

20 | Wolf Customer Care 800.222.7820


E Series Ovens

Electrical Requirements
24" OVEN 30" OVEN
Installation must comply with all applicable electrical codes. Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
Locate the electrical supply as shown in the illustrations
within the shaded area shown in the illustrations on the
on the following pages. A separate circuit servicing only
following pages. For ease of installation, the electrical
this appliance is required. A ground fault circuit interrupter
supply for the oven can be placed in an adjacent cabinet
(GFCI) is not recommended and may cause interruption
within reach of the conduit.
of operation. Refer to the illustration below for minimum
power cord plug clearance. Performance may be compromised if the electrical supply
is less than 240 volts.
Performance may be compromised if the electrical supply
is less than 240 volts. The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground con-
ELECTRICAL REQUIREMENTS—24" OVEN ductor. The wiring diagram covering the control circuit is
provided with the oven.
Electrical Supply grounded, 240/208 VAC, 60 Hz

Service 20 amp dedicated circuit


ELECTRICAL REQUIREMENTS—SINGLE OVEN
Receptacle NEMA 6-20R grounding-type Electrical Supply grounded, 240/208 VAC, 60 Hz
Power Cord 6' (1.8 m) Service 30 amp dedicated circuit

Conduit 4' (1.2 m)

Total Amps 22

Max Connected Load 5.4 kW

ELECTRICAL REQUIREMENTS­—DOUBLE OVEN

Electrical Supply grounded, 240/208 VAC, 60 Hz

1" (25) Service 50 amp dedicated circuit

Conduit 5' (1.5 m)


MINIMUM
CORD Total Amps 45
CLEARANCE
Max Connected Load 10.8 kW

Power cord clearance

wolfappliance.com | 21
E Series Ovens

24" E Series Single Oven


STANDARD INSTALLATION

23" (584)
OPENING
DEPTH

TOP VIEW

E E

23 1/4"
(591)
OPENING
HEIGHT

22 1/8" (562)
OPENING WIDTH

SIDE VIEW FRONT VIEW

22 | Wolf Customer Care 800.222.7820


E Series Ovens

24" E Series Single Oven


FLUSH INSET INSTALLATION

24" (610)
FLUSH
INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

E E 3/8" (10)

23 3/4" (603)
FLUSH INSET
HEIGHT** 13/16" (21)

1/8" (3)

23 3/4" (603)
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

wolfappliance.com | 23
E Series Ovens

30" E Series Single Oven


STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E
(127)
4"
(102)
27 1/2"
(699) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

24 | Wolf Customer Care 800.222.7820


E Series Ovens

30" E Series Single Oven


FLUSH INSET INSTALLATION

24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

30 1/8" (765)
FLUSH INSET WIDTH**

5"
11/8" (29) (127) E
4"
(102)
28 3/4"
(730)
FLUSH INSET
HEIGHT**

13/16" (21) E

1/8" (3)
E

SIDE VIEW FRONT VIEW

*Shaded areas will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

wolfappliance.com | 25
E Series Ovens

30" E Series Double Oven


STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E
(127)
4"
(102)

49 7/8"
(1267) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT

E
17" (432)
TYPICAL

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

26 | Wolf Customer Care 800.222.7820


E Series Ovens

30" E Series Double Oven


FLUSH INSET INSTALLATION

24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

30 1/8" (765)
FLUSH INSET WIDTH**

5"
11/8" (29) (127) E
4"
(102)

51 1/8"
(1299)
FLUSH INSET
HEIGHT**

13/16" (21) E

1/8" (3)
E
17" (432)
TYPICAL

SIDE VIEW FRONT VIEW

*Shaded areas will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

wolfappliance.com | 27
E Series Ovens

30" E Series Single Oven


DUAL STANDARD INSTALLATION

23 1/4" (591)
OPENING
DEPTH

TOP VIEW

5" E 5" E
(127) (127)
4" 4"
(102) (102)
27 1/2"
(699)
OPENING 58 1/2" (1486)
HEIGHT OPENING WIDTH

E E

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

28 | Wolf Customer Care 800.222.7820


E Series Ovens

30" E Series Single Oven


DUAL FLUSH INSET INSTALLATION

24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

60 1/8" (1527)
FLUSH INSET WIDTH**

5" E 5" E
11/8" (29) (127) (127)
4" 4"
(102) (102)
28 3/4"
(730)
FLUSH INSET
HEIGHT**

13/16" (21)

1/8" (3)
E E

SIDE VIEW FRONT VIEW

*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.

wolfappliance.com | 29
Convection Steam Ovens

Convection Steam Ovens


MODELS
TRANSITIONAL

CSO2450TE/S/T CSO3050TM/S/T CSO3050TE/S/T


CSOP2450TE/S/T CSOP3050TM/S/T CSOP3050TE/S/T

PROFESSIONAL

CSO3050PM/S/P CSO3050PE/S/P
CSOP3050PM/S/P CSOP3050PE/S/P

CONTEMPORARY

CSO3050CM/B/T
CSOP3050CM/B/T

CONTEMPORARY HANDLELESS

CSO2450CM/S CSO3050CM/S CSO3050CM/B


CSOP2450CM/S CSOP3050CM/S CSOP3050CM/B

30 | Wolf Customer Care 800.222.7820


Convection Steam Ovens

Convection Steam Ovens


TRANSITIONAL

7/8" A
(22)

17 7/8" 17 1/2"
(454) (446)

W 2 1/2" 22 1/2" (572)


WIDTH (64) BEHIND FRAME

14 3/16"
OPEN OVEN DOOR (360)

WIDTH W A

24" Transitional 231/2" (597) 211/2" (546)

30" Transitional 297/8" (759) 283/8" (721)

PROFESSIONAL

7/8" 28 3/8"
(22) (721)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 3 1/4" 22 1/2" (572)


(759) (83) BEHIND FRAME

14 3/16"
OPEN OVEN DOOR (360)

wolfappliance.com | 31
Convection Steam Ovens

Convection Steam Ovens


CONTEMPORARY

7/8" 28 3/8"
(22) (721)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 2 1/2" 22 1/2" (572)


(759) (64) BEHIND FRAME

14 3/16"
OPEN OVEN DOOR (360)

CONTEMPORARY HANDLELESS

7/8" A
(22)

17 7/8" 17 1/2"
(454) (446)

W 22 1/2" (572)
WIDTH BEHIND FRAME

14 3/16"
OPEN OVEN DOOR (360)

WIDTH W A

24" Contemporary Handleless 231/2" (597) 211/2" (546)

30" Contemporary Handleless 297/8" (759) 283/8" (721)

32 | Wolf Customer Care 800.222.7820


Convection Steam Ovens

Planning Information
The Convection Steam Oven can be installed in a standard INSTALLATION REQUIREMENTS
or flush inset application. The back of the base support Minimum Base Support 150 lb (68 kg)
must be open for water and drain line accessibility and
TRIM OVERLAP 24" MODEL 30" MODEL
routing. Refer to the illustration below.
Top 3/16" (5) 3/16" (5)
Finish the edges of the opening. They may be visible when Bottom 0" (0) 0" (0)
the door is open. Sides 5/8" (16) 11/16" (18)

For standard installations, the face trim overlaps stiles and


rails. Refer to the chart.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.

BACK OF
CABINET

4" (102)

18"
(457)

CL

Base support

wolfappliance.com | 33
Convection Steam Ovens

Electrical Requirements
Installation must comply with all applicable electrical codes. ELECTRICAL REQUIREMENTS

For ease of installation, the electrical supply for the oven Electrical Supply grounded, 240/208 VAC, 60 Hz
should be placed in an adjacent cabinet within reach of the Service 20 amp dedicated circuit
conduit.
Conduit 4' (1.2 m)
Performance may be compromised if the electrical supply
Total Amps 18
is less than 240 volts.
Max Connected Load 4.2 kW
The oven is supplied with a conduit consisting of two
hot lead conductors and a ground conductor. The wiring
diagram covering the control circuit is provided with the
oven.

34 | Wolf Customer Care 800.222.7820


Convection Steam Ovens

Plumbing Requirements
PLUMBED MODELS ONLY PLUMBING REQUIREMENTS

IMPORTANT NOTE: The unit needs minerals in the water Water Connection 6.5' (2 m) braided tubing with
to operate. Do not connect to a filtered water supply. 3/8" female compression fitting

Drain Connection 10' (3 m) corrugated tubing


Installation must comply with all applicable plumbing
codes. Pressure 15–145 psi (1–10 bar)

IMPORTANT NOTE: The drain connection must be able to


withstand temperatures up to 130°F (55°C).
The drain tube connection must be a minimum 2" (51)
below the unit and a minimum 4" (102) from the floor.
Locate the drain and water connections below the unit
or in an adjacent cabinet. Any opening into the adjacent
cabinet must meet the following: the longest dimension of
the opening shall not be more than 11/2" (38). The edges of
the opening must be smooth and round.
IMPORTANT NOTE: The drain location can vary, but must
be within reach of the corrugated tubing. Do not extend or
reduce the drain tubing. A drain line high loop is required.
Refer to the illustrations below.
Connect the water supply to a cold water house supply
with an easily accessible shut-off valve between the supply
and the unit.

2 3/4" (70) 2" (51)


TO 5" (127) MIN
2" (51)
MIN 2 3/4" (70)
TO 5" (127)
2" (51)
DRAIN TO
CONNECTION 27 1/2" 2" (51)
(699) TO
DRAIN 27 1/2"
CONNECTION (699)

Drain connection A Drain connection B

wolfappliance.com | 35
Convection Steam Ovens

Convection Steam Oven


STANDARD INSTALLATION

23" (584)
OPENING
DEPTH

TOP VIEW

E
17 11/16"
(449)
OPENING
HEIGHT
E

E
W
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

OPENING WIDTH W

24" Model 221/8" (562)

30" Model 281/2" (724)

36 | Wolf Customer Care 800.222.7820


Convection Steam Ovens

Convection Steam Oven


FLUSH INSET INSTALLATION

24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

5/16" (8) E
18 1/8"
(460)
FLUSH INSET A
HEIGHT**
1/8" (3)
E

E
W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

OPENING WIDTH W A

24" Model 233/4" (603) 13/16" (21)

30" Model 301/8" (765) 13/16" (21)

wolfappliance.com | 37
Speed Ovens

Speed Ovens
MODELS
TRANSITIONAL

SPO24TE/S/TH SPO30TM/S/TH SPO30TE/S/TH

PROFESSIONAL

SPO30PM/S/PH SPO30PE/S/PH

CONTEMPORARY

SPO30CM/B/TH

38 | Wolf Customer Care 800.222.7820


Speed Ovens

Speed Ovens
TRANSITIONAL

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

W 2 1/2" 21 1/2" (546)


WIDTH (64) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

WIDTH W

24" Transitional 231/2" (597)

30" Transitional 297/8" (759)

wolfappliance.com | 39
Speed Ovens

Speed Ovens
PROFESSIONAL

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 3 1/4" 21 1/2" (546)


(759) (83) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

CONTEMPORARY

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 2 1/2" 21 1/2" (546)


(759) (64) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

40 | Wolf Customer Care 800.222.7820


Speed Ovens

Planning Information
The Speed Oven can be installed in a standard or flush ELECTRICAL REQUIREMENTS
inset application.
Installation must comply with all applicable electrical codes.
Finish the edges of the opening. They may be visible when
Locate the electrical supply as shown in the illustrations on
the door is open.
the following pages. The receptacle may also be located
For standard installations, the face trim will overlap stiles in an adjacent cabinet within reach of the power cord. A
and rails. Refer to the chart below. separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
For flush inset installations, a minimum 1/8" (3) reveal is
and may cause interruption of operation. Refer to the illus-
required on all sides. To ensure consistent reveals, each
tration below for minimum power cord plug clearance.
corner of the opening must be exactly 90°.
If the Speed Oven is installed above or below a Wolf E ELECTRICAL REQUIREMENTS
Series Oven in a flush inset application, a 1/4" (6) reveal is
Electrical Supply grounded, 240/208 VAC, 60 Hz
required.
Service 15 amp dedicated circuit
INSTALLATION REQUIREMENTS Receptacle NEMA 6-20R grounding type
BASE SUPPORT MIN Power Cord 6' (1.8 m)
24" (610) Model 125 lb (57 kg)
30" (762) Model 125 lb (57 kg)

TRIM OVERLAP 24" MODEL 30" MODEL


Top 3/16" (5) 3/16" (5)
Bottom 0" (0) 0" (0)
Sides 11/16" (18) 37/8" (98) NEMA
PLUG

1" (25)

MINIMUM
CORD
GROUNDED CLEARANCE
NEMA RECEPTACLE

NEMA 6-20R receptacle Power cord clearance

wolfappliance.com | 41
Speed Ovens

Speed Oven
STANDARD INSTALLATION

23" (584)
OPENING
DEPTH

TOP VIEW

E
17 11/16"
(449)
OPENING
HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: 24" (610) and 30" (762) models require the same opening dimensions.

OPENING WIDTH W

24" Model 221/8" (562)

30" Model 221/8" (562)

42 | Wolf Customer Care 800.222.7820


Speed Ovens

Speed Oven
FLUSH INSET INSTALLATION

24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

E 5/16" (8)
18 1/8"
(460)
FLUSH INSET
A
HEIGHT**
1/8" (3)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

24" Model 233/4" (603) 13/16" (21)

30" Model 301/8" (765) 4" (102)

wolfappliance.com | 43
Microwave Ovens

Microwave Ovens
DROP-DOWN DOOR MICROWAVES
TRANSITIONAL

MDD24TE/S/TH MDD30TM/S/TH MDD30TE/S/TH

PROFESSIONAL

MDD30PM/S/PH MDD30PE/S/PH

CONTEMPORARY

MDD30CM/B/TH

DRAWER MICROWAVE
TRANSITIONAL

MD24TE/S MD30TE/S

PROFESSIONAL

MD30PE/S

CONVECTION MICROWAVE

MC24 (M/E SERIES TRIM)

STANDARD MICROWAVE

MS24 (M/E SERIES TRIM)

44 | Wolf Customer Care 800.222.7820


Microwave Ovens

Drop-Down Door Microwave Ovens


TRANSITIONAL

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

W 2 1/2" 20" (508)


WIDTH (64) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

WIDTH W

24" Transitional 231/2" (597)

30" Transitional 297/8" (759)

PROFESSIONAL

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 3 1/4" 20" (508)


(759) (83) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

CONTEMPORARY

7/8" 21 3/16"
(22) (538)

17 7/8" 17 1/2"
(454) (446)

29 7/8" 2 1/2" 20" (508)


(759) (64) BEHIND FRAME

OPEN
14 3/16"
(360)
OVEN DOOR

wolfappliance.com | 45
Microwave Ovens

Drawer Microwave Ovens


TRANSITIONAL / PROFESSIONAL 21 5/8" (549)

1 3/8" 13/4" POWER CORD 4 5/8"


(35) (45) CHANNEL (118)

15 1/8" 14 5/8"
(384) (372)

W 21 7/8" (556)
WIDTH BEHIND FRAME OPEN DRAWER
16 5/8"
(422)

WIDTH W

24" Model 237/8" (606)

30" Model 297/8" (759)

46 | Wolf Customer Care 800.222.7820


Microwave Ovens

Convection Microwave Oven Standard Microwave Oven


M/E SERIES TRIM M/E SERIES TRIM

24 3/4" (629) 1" (25) OR 24" (610) 1" (25) OR


FREESTANDING 11/4" (32)* FREESTANDING 11/4" (32)*

19 7/8" 14 7/8" 18 1/4" 13 3/8"


(505) (378) (464) (340)
WITH FREE- WITH FREE-
TRIM STANDING TRIM STANDING

W 18" (457) W 18" (457)


TRIM WIDTH BEHIND TRIM TRIM WIDTH BEHIND TRIM

*11/4" (32) for contemporary E series trim only. *11/4" (32) for contemporary E series trim only.

TRIM WIDTH M SERIES E SERIES TRIM WIDTH M SERIES E SERIES

27" Trim NA 267/8" (683) 27" Trim NA 267/8" (683)

30" Trim 297/8" (759) 297/8" (759) 30" Trim 297/8" (759) 297/8" (759)

wolfappliance.com | 47
Microwave Ovens

Planning Information
DROP-DOWN DOOR MICROWAVE DRAWER MICROWAVE
The Drop-Down Door Microwave Oven can be installed in The Drawer Microwave Oven can be installed in a standard
a standard or flush inset application. or flush inset application. The location of the electrical
supply within the oven opening may require additional
Finish the edges of the opening. They may be visible when
cabinet depth.
the door is open.
Finish the edges of the opening. They may be visible when
For standard installations, the face trim will overlap stiles
the drawer is open.
and rails. Refer to the chart below.
For standard installations, the face trim will overlap stiles
For flush inset installations, a minimum 1/8" (3) reveal is
and rails. Refer to the chart below.
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°. For flush inset installations, a minimum 1/8" (3) reveal is
required on the top and sides and 11/16" (18) on the bottom.
INSTALLATION REQUIREMENTS To ensure consistent reveals, each corner of the opening
BASE SUPPORT MIN
must be exactly 90°. A sales accessory is required to direct
Drop-Down Door Microwave 125 lb (57 kg) air away from the unit. Accessories are available through
an authorized Wolf dealer. For local dealer information,
TRIM OVERLAP 24" MODEL 30" MODEL
visit the find a showroom section of our website,
Top 3/16" (5) 3/16" (5)
wolfappliance.com.
Bottom 0" (0) 0" (0)
Sides 11/16" (18) 37/8" (98)
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Drawer Microwave 125 lb (57 kg)
30" Drawer Microwave 125 lb (57 kg)

TRIM OVERLAP 24" MODEL 30" MODEL


Top 5/16" (8) 5/16" (8)
Bottom 1/16" (2) 1/16" (2)
Sides 7/8" (22) 37/8" (98)

48 | Wolf Customer Care 800.222.7820


Microwave Ovens

Planning Information Electrical Requirements


CONVECTION / STANDARD MICROWAVES Installation must comply with all applicable electrical codes.
Convection and Standard Microwave Ovens can be Locate the electrical supply as shown in the illustrations on
installed in a standard or flush inset application using the following pages. The receptacle may also be located
accessory trim to match Wolf ovens. Trim kits are avail­able in an adjacent cabinet within reach of the power cord. A
through an authorized Wolf dealer. For local dealer infor- separate circuit servicing only this appliance is required. A
mation, visit the find a showroom section of our website, ground fault circuit interrupter (GFCI) is not recommended
wolfappliance.com. and may cause interruption of operation. Refer to the illus-
tration below for minimum power cord plug clearance.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
ELECTRICAL REQUIREMENTS
Convection and Standard Microwave Ovens can also be
Electrical Supply grounded, 120 VAC, 60 Hz
used freestanding. For freestanding applications, a mini-
mum 2" (51) space is required at the top, rear, and sides of Service 15 amp dedicated circuit
the microwave oven for air circulation. Receptacle 3-prong grounding-type

Power Cord 4' (1.2 m)


INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Convection Microwave 125 lb (57 kg)
Standard Microwave 125 lb (57 kg)

27" E SERIES TRIM OVERLAP CONVECTION STANDARD


Top 1/4" (6) 9/16" (14)
Bottom 3/4" (19) 11/16" (17)
Sides 13/16" (21) 13/16" (21)

30" M/E SERIES TRIM OVERLAP CONVECTION STANDARD


Top 1/4" (6) 9/16" (14) 3"
(76)
Bottom 3/4" (19) 11/16" (17)
Sides 13/16" (30) 13/16" (30)
MINIMUM CORD
CLEARANCE

Power cord clearance

wolfappliance.com | 49
Microwave Ovens

Drop-Down Door Microwave Oven


STANDARD INSTALLATION

21 9/16"
(548)
OPENING
DEPTH

TOP VIEW

E
17 11/16"
(449)
OPENING
HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: 24" (610) and 30" (762) models require the same opening dimensions.

OPENING WIDTH W

24" Model 221/8" (562)

30" Model 221/8" (562)

50 | Wolf Customer Care 800.222.7820


Microwave Ovens

Drop-Down Door Microwave Oven


FLUSH INSET INSTALLATION

23" (584)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

E 5/16" (8)
18 1/8"
(460)
FLUSH INSET
A
HEIGHT**
1/8" (3)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

24" Model 233/4" (603) 13/16" (21)

30" Model 301/8" (765) 4" (102)

wolfappliance.com | 51
Microwave Ovens

Drawer Microwave Oven


STANDARD INSTALLATION

22" (559)
OPENING
DEPTH

TOP VIEW

ANTI-TIP BLOCK

E
14 3/4" (375)
OPENING
HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: All drawer microwave ovens require the same opening dimensions.

OPENING WIDTH W

24" Model 22 1/8" (562)

30" Model 22 1/8" (562)

52 | Wolf Customer Care 800.222.7820


Microwave Ovens

Drawer Microwave Oven


FLUSH INSET INSTALLATION

23 3/8" (594)
FLUSH INSET
1 3/8" (35) DEPTH
FINISHED
CLEATS*

TOP VIEW

ANTI-TIP BLOCK

E 7/16" (11)
15 15/16" (405)
FLUSH INSET A
HEIGHT**
3/4" (19)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

24" Model 24 1/8" (613) 1" (25)

30" Model 30 1/8" (765) 4" (102)

wolfappliance.com | 53
Microwave Ovens

Convection Microwave Oven


STANDARD INSTALLATION WITH TRIM

20 1/8" (511)
OPENING
DEPTH

TOP VIEW

18 7/8" (479)
OPENING
HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

OPENING WIDTH W

27" Trim 251/4" (641)

30" Trim 271/2" (699)

54 | Wolf Customer Care 800.222.7820


Microwave Ovens

Convection Microwave Oven


FLUSH INSET INSTALLATION WITH TRIM

23 1/4" (591)
FLUSH INSET
1" (25) DEPTH
FINISHED
CLEATS*

TOP VIEW

E 3/8" (10)

20 1/8" (511)
FLUSH INSET A
HEIGHT**
7/8" (22)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

27" Trim 271/8" (689) 15/16" (24)

30" Trim 301/8" (765) 13/16" (30)

wolfappliance.com | 55
Microwave Ovens

Standard Microwave Oven


STANDARD INSTALLATION WITH TRIM

20" (508)
OPENING
DEPTH

TOP VIEW

17" (432)
OPENING
HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

OPENING WIDTH W

27" Trim 251/4" (641)

30" Trim 271/2" (699)

56 | Wolf Customer Care 800.222.7820


Microwave Ovens

Standard Microwave Oven


FLUSH INSET INSTALLATION WITH TRIM

23 1/4" (591)
FLUSH INSET
1" (25) DEPTH
FINISHED
CLEATS*

TOP VIEW

E 11/16" (17)

18 1/2" (470)
FLUSH INSET A
HEIGHT**
13/16" (21)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

27" Trim 271/8" (689) 15/16" (24)

30" Trim 301/8" (765) 13/16" (30)

wolfappliance.com | 57
Warming Drawers

Warming Drawers
WARMING DRAWER FRONTS
M SERIES

TRANSITIONAL PROFESSIONAL CONTEMPORARY

E SERIES

TRANSITIONAL PROFESSIONAL

INTEGRATED

CUSTOM PANEL

58 | Wolf Customer Care 800.222.7820


Warming Drawers

Warming Drawers
DRAWER FRONT OPTIONS DIMENSIONS
Wolf Warming Drawer fronts allow for many design A
options, but the warming drawer itself will be the same
for all applications. A panel mounting kit is required when 10 3/8" 9"
(264) (229)
installing a custom panel. The panel mounting kit is avail-
able through an authorized Wolf dealer. For local dealer
information, visit the find a showroom section of our W B 22 3/4" (578)
WIDTH
website, wolfappliance.com.
28 1/4" (718)
The 2" (51) thick drawer front, in 30" and 36" widths, is
designed to be installed below a Wolf Sealed Burner
Rangetop or Outdoor Grill, so the panel aligns properly
with the front of the rangetop or grill. Dimensions for the
warming drawer remain the same, even though the drawer
front may be wider to match the Sealed Burner Rangetop
or Outdoor Grill.

211/2"
OPEN DRAWER (546)

STAINLESS STEEL DRAWER FRONT


WIDTH W
30" Drawer Front 297/8" (759)
36" Drawer Front 357/8" (911)

M/E SERIES A B
Stainless 7/8" (22) 31/4" (83)
Black 1" (25) 33/8" (86)
Stainless (2" thick) 21/8" (54) 41/2" (114)

INTEGRATED DRAWER FRONT


CUSTOM PANEL W H D
Dimensions (typical) 297/8" (759) 103/8" (264) 3/4" (19)
Min Thickness 5/8" (16)

wolfappliance.com | 59
Warming Drawers

Planning Information
The Warming Drawer must be installed with a Wolf drawer INSTALLATION REQUIREMENTS
front, avail­able through an authorized Wolf dealer. For Min Base Support 200 lb (90 kg)
local dealer information, visit the find a showroom section
Trim Overlap (top, bottom, sides) 5/8" (16)
of our website, wolfappliance.com. Specific installation
instructions are included with the drawer front.
The Warming Drawer can be installed in a standard or flush
inset application.
For a standard installation, the drawer collar and front
panel sit proud of the cabinet face frame. A recessed
installation requires the cabinetry be recessed by 3/16" (5)
so the collar is flush with the cabinet face frame but the
drawer front will sit proud. A flush inset installation requires
the drawer collar and front panel be recessed to be flush
with surrounding cabinetry. Refer to illustrations on the
following pages for minimum cabinet dimensions for your
specific installation.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.

60 | Wolf Customer Care 800.222.7820


Warming Drawers

Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adja-
cent cabinet within reach of the power cord.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 3' (.9 m)

wolfappliance.com | 61
Warming Drawers

Warming Drawer
STANDARD INSTALLATION

23" (584)
OPENING
DEPTH

TOP VIEW

ANTI-TIP BLOCK

91/8" (232)
OPENING
HEIGHT E

28 5/8" (727)
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: Location of electrical supply within opening may require additional cabinet depth.

62 | Wolf Customer Care 800.222.7820


Warming Drawers

Warming Drawer
FLUSH INSET INSTALLATION

A
DRAWER 24" (610)
FRONT FLUSH INSET
DEPTH DEPTH
FINISHED
CLEATS*

TOP VIEW

ANTI-TIP BLOCK

10 5/8" 3/4" (19)


(270)
FLUSH INSET 3/4" (19)
HEIGHT**
E

3/4" (19)
E
30 1/8" (765)
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.

M/E SERIES DRAWER FRONT DEPTH A

Stainless 11/8" (29)

Black 13/8" (35)

Stainless (2" thick) 21/8" (54)

Custom front panel depth is dependent on panel thickness. Add 1/4" (6)
to the panel thickness to determine the drawer front depth.

wolfappliance.com | 63
Induction/Electric Cooktops

Induction Cooktops
MODELS
TRANSITIONAL

CI30460T/S CI36560T/S

CONTEMPORARY

CI30460C/B CI36560C/B

TRANSITIONAL FRAMED

CI243TF/S CI304TF/S

CI365TF/S

64 | Wolf Customer Care 800.222.7820


Induction Cooktops

Induction Cooktops
30" TRANSITIONAL 36" TRANSITIONAL

21" 21"
(533) (533)

30" (762) 36" (914)

CONDUIT 2" (51) CONDUIT 2" (51)

7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)

30" CONTEMPORARY 36" CONTEMPORARY

21" 21"
(533) (533)

30" (762) 36" (914)

CONDUIT 2 1/2" (64) CONDUIT 2 1/2" (64)

7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)

24" TRANSITIONAL FRAMED 30" TRANSITIONAL FRAMED 36" TRANSITIONAL FRAMED

21" 21" 21"


(533) (533) (533)

23 5/8" (600) 30" (762) 36" (914)

CONDUIT 2" (51) CONDUIT 2" (51) CONDUIT 2" (51)

7/8" 7/8" 7/8"


11/4" (32) (22) 11/4" (32) (22) 11/4" (32) (22)

wolfappliance.com | 65
Electric Cooktops

Electric Cooktops
MODELS
TRANSITIONAL

CE304T/S CE365T/S

CONTEMPORARY

CE304C/B CE365C/B

66 | Wolf Customer Care 800.222.7820


Electric Cooktops

Electric Cooktops
30" TRANSITIONAL 36" TRANSITIONAL

21" 21"
(533) (533)

30" (762) 36" (914)

CONDUIT 3 1/2" (89) CONDUIT 3 1/2" (89)

7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)

30" CONTEMPORARY 36" CONTEMPORARY

21" 21"
(533) (533)

30" (762) 36" (914)

CONDUIT 4" (102) CONDUIT 4" (102)

7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)

wolfappliance.com | 67
Induction/Electric Cooktops

Planning Information
A minimum 2" (51) is required from the bottom of the MULTIPLE COOKTOPS
cooktop to combustible materials.
When multiple cooktops or modules are installed side by
Clearance is required for the conduit located at the right side, the countertop cutout width is determined by adding
rear of the cooktop. Refer to the illustrations on the the width of each unit, then subtracting 1" (25). Refer to the
previous pages for dimensions for Induction and Electric illustration below.
Cooktops. Refer to the illustrations on the following pages
IMPORTANT NOTE: Contemporary Induction and Electric
for additional minimum clearances.
Cooktops are not designed to be installed in combination
with other cooktops.
FLUSH INSTALLATION
Contemporary Induction and Electric Cooktops can be
mounted flush with the top of the countertop or as a
frameless standard installation sitting on top of the coun- 2 1/2" (64)
tertop surface. If the cooktop is to be mounted flush with
the countertop, a recessed area surrounding the cooktop 19 1/2"
cutout must be provided. (495)
CUTOUT
DEPTH
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface, or stone countertop surfaces
2 1/2" (64)
only.
CUTOUT WIDTH
(COMBINED WIDTH OF COOKTOPS MINUS 1")

Countertop cutout

68 | Wolf Customer Care 800.222.7820


Induction/Electric Cooktops

Electrical Requirements
Installation must comply with all applicable electrical codes.
Refer to the illustrations on the following pages for loca-
tion of the electrical supply for Induction and Electric
Cooktops. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
When multiple cooktops are installed side by side, each
unit must have its own separate recommended electrical
circuit.

ELECTRICAL REQUIREMENTS
INDUCTION
Electrical Supply grounded 3-wire, 240/208 VAC, 60 Hz
Conduit flexible 4' (1.2 m)

ELECTRIC
Electrical Supply grounded 3-wire, 240 VAC, 60 Hz
Electrical Supply (208 V) grounded 3-wire, 208 VAC, 60 Hz
Conduit flexible 4' (1.2 m)

SERVICE
24" Induction 30 amp dedicated circuit
30" Induction/Electric 40 amp dedicated circuit
36" Induction/Electric 50 amp dedicated circuit

wolfappliance.com | 69
Induction/Electric Cooktops

24" / 30" / 36" Cooktop


STANDARD INSTALLATION

2 1/2" (64)

W 19 1/2"
WIDTH (495)

2 1/2" (64)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

2"
(51)

4 1/2" (114)
3 1/2" (89) E
10" (254)

36" (914) min


FLOOR TO
COUNTERTOP

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.

CUTOUT WIDTH W

24" Induction 221/8" (562)

30" Induction/Electric 29" (737)

36" Induction/Electric 35" (889)

70 | Wolf Customer Care 800.222.7820


Induction/Electric Cooktops

24" / 30" / 36" Cooktop


FLUSH INSTALLATION

2 1/2" (64)
COUNTERTOP
PROFILE
5/16" (8) W
211/8" CUTOUT WIDTH 19 1/2"
(537) (495)
RECESS A
RECESS

19/16" (40) min 2 1/2" (64)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

2"
(51)

4 1/2" (114)
3 1/2" (89) E
10" (254)

36" (914) min


FLOOR TO
COUNTERTOP

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.
Outside corner radius 7/16 " (11).

CUTOUT WIDTH W A

24" Induction 221/8" (562) 233/4" (603)

30" Induction/Electric 29" (737) 301/8" (765)

36" Induction/Electric 35" (889) 361/8" (918)

wolfappliance.com | 71
Gas Cooktops

Gas Cooktops
MODELS
TRANSITIONAL FRAMED

CG243TF/S

TRANSITIONAL

CG304T/S CG365T/S

PROFESSIONAL

CG304P/S CG365P/S

CONTEMPORARY

CG365C/S

72 | Wolf Customer Care 800.222.7820


Gas Cooktops

Gas Cooktops
24" TRANSITIONAL 30" TRANSITIONAL 36" TRANSITIONAL

21" 21" 21"


(533) (533) (533)

23 5/8" (600) 30" (762) 36" (914)

4" (102) 4" (102) 4" (102)

3/8" 7/8" 7/8"


(10) (22) (22)

30" PROFESSIONAL 36" PROFESSIONAL

21" 21"
(533) (533)

30" (762) 36" (914)

4" (102) 4" (102)

7/8" 7/8"
(22) (22)

36" CONTEMPORARY

20 15/16"
(532)

35 15/16" (913)

6 3/4" (171)

7/8"
(22)

wolfappliance.com | 73
Gas Cooktops

Planning Information
A minimum 2" (51) is required from the bottom of the GAS SUPPLY
cooktop to combustible materials. If the cooktop is
Installation must comply with all applicable gas codes.
installed above an oven, a minimum of 1/4" (6) is required
between the units. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
The Contemporary Gas Cooktop can be mounted flush
with the top of the countertop, or as a standard installation Wolf natural gas cooktops will function up to 10,250'
sitting on top of the countertop surface. If the cooktop is (3124 m) in altitude without adjustment and LP gas cook-
to be mounted flush with the countertop, a recessed area tops will function up to 8,600' (2621 m). If the installation
surrounding the cooktop cutout must be provided. The exceeds these elevations, contact an authorized Wolf
countertop must be able to withstand temperatures up to dealer for a high altitude conversion kit.
300°F (149°C).
GAS REQUIREMENTS
Control knobs for the Contemporary Gas Cooktop are
designed to be mounted on the front face of cabinetry Gas Supply 3/4" ID line
below the unit. Mounting holes must be drilled through the Gas Inlet 1/2" NPT male
cabinet face. Refer to the illustrations on pages 76–77 for
NATURAL GAS WC
the hole location.
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
ELECTRICAL REQUIREMENTS Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

Installation must comply with all applicable electrical codes. LP GAS WC


Supply Pressure 10" (25 mb)
Locate the electrical supply as shown in the illustrations Min Line Pressure 11" (27.4 mb)
on the following pages. A separate circuit servicing only Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 6' (1.8 m)

74 | Wolf Customer Care 800.222.7820


Gas Cooktops

24" / 30" / 36" Transitional / Professional Gas Cooktop


STANDARD INSTALLATION

2 1/2" (64)

W 19 1/2"
WIDTH (495)

2 1/2" (64)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

9"
(229)

4" (102)
3 1/2" (89) E G
10" (254)

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical and gas supply location only applies to installations with built-in oven.

CUTOUT WIDTH W

24" Transitional 23" (584)

30" Transitional/Professional 29" (737)

36" Transitional/Professional 35" (889)

wolfappliance.com | 75
Gas Cooktops

36" Contemporary Gas Cooktop


STANDARD INSTALLATION

2 1/2" (64)

35" (889) 20"


CUTOUT WIDTH (508)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

9"
(229)

3 7(102)
4" /8" (98) MIN – 51/8" (130) MAX
2" (51) MIN – CL
5" (127) MAX 5"
(127) 11/4" (32)
DIAMETER
10"
(254)
CL E G

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines.

76 | Wolf Customer Care 800.222.7820


Gas Cooktops

36" Contemporary Gas Cooktop


FLUSH INSTALLATION

2 1/2" (64)
COUNTERTOP
PROFILE
5/64" (2) 35" (889)
21" CUTOUT WIDTH 20"
(533) MIN (508)
RECESS 36" (914) MIN
RECESS

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

9"
(229)

3 7(102)
4" /8" (98) MIN – 51/8" (130) MAX
2" (51) MIN – CL
5" (127) MAX 5"
(127) 11/4" (32)
DIAMETER
10"
(254)
CL E G

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines.
Outside corner radius 3 /8 " (10).

wolfappliance.com | 77
Module Cooktops

Module Cooktops
MODELS

CI152TF/S SM15TF/S FM15TF/S GM15TF/S


INDUCTION STEAMER FRYER GRILL

TM15TF/S CG152TF/S MM15TF/S


TEPPANYAKI GAS MULTI-FUNCTION

78 | Wolf Customer Care 800.222.7820


Module Cooktops

Module Cooktops
INDUCTION STEAMER FRYER GRILL

21" 21" 21" 21"


(533) (533) (533) (533)

15" 15" 15" 15"


(381) (381) (381) (381)

CONDUIT 2" (51) 8 3/4" 5"


8 3/4" (127)
(222) (222)
7/8"
7/8"
11/4" (22) 7/8" 4" 7/8" 4"
(32) 11/4" (22)
(22) (102) (22) (102) (32)
DRAIN DRAIN
OUTLET OUTLET

TEPPANYAKI GAS MULTIFUNCTION

21" 21" 21"


(533) (533) (533)

15" 15" 15"


(381) (381) (381)

4" (102) 4" (102) 5" (127)

7/8" 7/8" 7/8"


(22) (22) (22)

wolfappliance.com | 79
Module Cooktops

Planning Information
IMPORTANT NOTE: Wolf does not recommend the use MULTIPLE COOKTOPS
of downdraft ventilation with the Steamer, Fryer, or Grill
When multiple cooktops or modules are installed side by
Modules.
side, refer to the chart and illustration below for typi-
A minimum 2" (51) is required from the bottom of the cal configurations. The cutout dimensions provided will
module to combustible materials. For the Teppanyaki accommodate the use of an optional filler strip if desired.
Module, a minimum 7/8" (22) is required from the bottom of
For specific multiple cooktop and module configuration
the unit to any material.
options or the installation of more than six modules, con-
Refer to the illustrations on the following pages for instal- tact Wolf Customer Care at 800-222-7820.
lation of Module Cooktops.
COUNTERTOP CUTOUT W

(2) 15" Modules* 29" (737)

(3) 15" Modules* 44" (1118)

(4) 15" Modules* 591/4" (1505)

(5) 15" Modules* 741/4" (1886)

(6) 15" Modules* 891/4" (2267)

24" Cooktop**/15" Module* 375/8" (956)

30" Cooktop/15" Module* 44" (1118)

30" Cooktop/(2) 15" Modules* 59" (1473)

36" Cooktop/15" Module* 50" (1270)

*Dimensions apply to CI152TF/S, CG152TF/S, SM15TF/S, FM15TF/S,


GM15TF/S, TM15TF/S and MM15TF/S.
**235/8" actual product width.

W
CUTOUT WIDTH

2 1/2"
(64) min 191/2"
(495)
CUTOUT
2 1/2" DEPTH
(64) min

FRONT OF COUNTERTOP

Countertop cutout

80 | Wolf Customer Care 800.222.7820


Module Cooktops

Planning Information
ELECTRICAL DRAIN OUTLET
Installation must comply with all applicable electrical codes. Steamer and Fryer Modules require a method for draining
hot water and oil. For the Steamer Module, options include
Locate the electrical supply as shown in the illustrations on
connecting a drain hose from the 5/8" (16) outlet tied into
the following pages. A separate circuit servicing only this
an existing drain, a separate drain with freefall, or placing
appliance is required.
a heat-resistant receptacle under the drain outlet. For the
When multiple cooktops or modules are installed side by Fryer Module, the drain outlet must be accessible to drain
side, each must have its own separate electrical supply. oil into a heat-resistant receptacle.

ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply grounded 3-wire, 240/208 VAC, 50/60 Hz
Steamer, Fryer, Grill, Teppanyaki 15 amp dedicated circuit
Induction 20 amp dedicated circuit
Conduit flexible 4' (1.2 m)

GAS MODULES
Electrical Supply grounded, 120 VAC, 50/60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)

wolfappliance.com | 81
Module Cooktops

Planning Information
GAS SUPPLY GAS REQUIREMENTS

Installation must comply with all applicable gas codes. Gas Supply 3/4" ID line

If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" Gas Inlet 1/2" NPT male
(19) ID flexible metal appliance connector is recommended. NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
When multiple gas cooktops or modules are installed side
Min Line Pressure 7" (17.5 mb)
by side, they can receive their gas supply from a common
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module. LP GAS WC
Supply Pressure 10" (25 mb)
Wolf natural gas cooktops will function up to 10,250' Min Line Pressure 11" (27.4 mb)
(3124 m) in altitude without adjustment and LP gas cook- Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
tops will function up to 8,600' (2621 m). If the installation
exceeds these elevations, contact an authorized Wolf
dealer for a high altitude conversion kit.

GAS REQUIREMENTS

Gas Supply 3/4" ID line

Gas Inlet 1/2" NPT male

NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

82 | Wolf Customer Care 800.222.7820


Module Cooktops

Induction Module
STANDARD INSTALLATION

2 1/2" (64)

14" 19 1/2"
(356) (495)

2 1/2" (64)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

2"
(51)

36" (914) min


FLOOR TO
COUNTERTOP

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.

wolfappliance.com | 83
Module Cooktops

Steamer Module
STANDARD INSTALLATION

2 1/2" (64) min

14" 19 1/2"
(356) (495)

2 1/2" (64) min

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

7"
(178)

7 7/8" 6"
(200) 12 3/8" (152)
(314)

DRAIN
OUTLET

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.

WARNING
The Steamer Module must be installed at least 15" (381)
from a Fryer Module.

84 | Wolf Customer Care 800.222.7820


Module Cooktops

Fryer Module
STANDARD INSTALLATION

2 1/2" (64) min

14" 19 1/2"
(356) (495)

2 1/2" (64) min

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

7"
(178)

7 7/8" 6"
(200) 12 3/8" (152)
(314)

DRAIN
OUTLET

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.

WARNING
The Fryer Module must be installed at least 15" (381)
from any open-flame cooking device or a Steamer
Module.

wolfappliance.com | 85
Module Cooktops

Grill / Teppanyaki Module


STANDARD INSTALLATION

2 1/2" (64) min

14" 19 1/2"
(356) (495)

2 1/2" (64) min

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

7"
(178)

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.

86 | Wolf Customer Care 800.222.7820


Module Cooktops

Gas / Multifunction Module


STANDARD INSTALLATION

2 1/2" (64)

14" 19 1/2"
(356) (495)

2 1/2" (64)

COUNTERTOP CUTOUT

13" 18" 30"


(330) (457) (762)

7"
(178)

E G

SIDE VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.

wolfappliance.com | 87
Coffee System

Coffee System
MODELS
24" TRANSITIONAL

EC2450TE/S

30" TRANSITIONAL

EC3050TE/S EC3050TM/S

30" PROFESSIONAL

EC3050PE/S EC3050PM/S

30" CONTEMPORARY

EC3050CM/S EC3050CM/B

88 | Wolf Customer Care 800.222.7820


Coffee System

Coffee System
DIMENSIONS

7/8"
(22)

17 7/8"
(454)

W 19" (483)
WIDTH BEHIND FRAME UNIT 181/4"
FULL EXTENSION (464)

WIDTH W

24" Model 231/2" (597)

30" Model 297/8" (759)

wolfappliance.com | 89
Coffee System

Planning Information
The Coffee System can be installed in a standard or flush COMBINATION INSTALLATIONS
inset application. The sides of the cabinet opening must
If a Coffee System is installed above a Cup Warming
be adequate to support installation of the mounting slides.
Drawer, specify one opening for both units. To achieve
Refer to the illustration below.
the minimum reveal between the units, place the Coffee
Finish the edges of the opening. System support rails on top of the Cup Warming Drawer,
then secure the rails to the sides of the cabinet. Any
For standard installations, the face trim overlaps stiles and
material between the units will increase the horizontal
rails. Refer to the chart below.
reveal between the two products.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. Each corner of the opening must be
exactly 90° to maintain consistent reveals.

INSTALLATION REQUIREMENTS

Minimum Base Support 100 lb (45 kg)

TRIM OVERLAP 24" MODEL 30" MODEL


Top 3/16" (5) 3/16" (5)
Bottom 0" (0) 0" (0)
Sides 11/16" (18) 37/8" (98)

3/4" (19)
TYPICAL

14"
(356) 3" (76)

Slide support

90 | Wolf Customer Care 800.222.7820


Coffee System

Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 6' (1.8 m)

wolfappliance.com | 91
Coffee System

Coffee System
STANDARD INSTALLATION

21 9/16"
(548)
SLIDE OPENING
SUPPORT DEPTH

TOP VIEW

17 11/16" (449)
SLIDE OPENING E
SUPPORT HEIGHT

W
OPENING WIDTH

SIDE VIEW FRONT VIEW

NOTE: 24" (610) model and 30" (762) model require the same opening dimensions.

OPENING WIDTH W

24" Model 221/8" (562)

30" Model 221/8" (562)

92 | Wolf Customer Care 800.222.7820


Coffee System

Coffee System
FLUSH INSET INSTALLATION

23" (584)
SLIDE FLUSH
SUPPORT INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

5/16" (8)

18 1/8" (460)
SLIDE FLUSH INSET A E
SUPPORT HEIGHT**
1/8" (3)

W
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

24" Model 233/4" (603) 13/16" (21)

30" Model 301/8" (765) 4" (102)

wolfappliance.com | 93
Cup Warming Drawer

Cup Warming Drawer


MODEL

CW24/S
STAINLESS

94 | Wolf Customer Care 800.222.7820


Cup Warming Drawer

Cup Warming Drawer Planning Information


DIMENSIONS The Cup Warming Drawer can be installed in a standard
or flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
5 1/2"
(140)
For standard installations, the face trim will overlap stiles
23 1/2" (597) 7/8" 21" (533) and rails. Refer to the chart below.
(22) BEHIND FRAME
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Cup Warming Drawer 75 lb (34 kg)

DRAWER 19" TRIM OVERLAP


FULL EXTENSION (483) Top 0" (0)
Bottom 0" (0)
Sides 11/16" (18)

COMBINATION INSTALLATION
To install a Cup Warming Drawer below a Coffee System,
one opening for both units must be specified. To achieve
the minimum reveal between the units, place the Coffee
System support rails on top of the Cup Warming Drawer,
then secure the rails to the sides of the cabinet. Any mate-
rial between the units will increase the horizontal reveal.

ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 10 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 3' (.9 m)

wolfappliance.com | 95
Cup Warming Drawer

Cup Warming Drawer


STANDARD INSTALLATION

22 1/2"
(572)
OPENING
DEPTH

TOP VIEW

ANTI-TIP BLOCK

5 1/2" (140) E
OPENING HEIGHT

22 1/8" (562)
OPENING WIDTH

SIDE VIEW FRONT VIEW

96 | Wolf Customer Care 800.222.7820


Cup Warming Drawer

Cup Warming Drawer


FLUSH INSET INSTALLATION

23 1/2" (597)
FLUSH
INSET
7/8" (22) DEPTH
FINISHED
CLEATS*

TOP VIEW

1/8" (3)
ANTI-TIP BLOCK

5 3/4" (146) 13/16"


E 1/8" (3)
FLUSH INSET HEIGHT** (21)

23 3/4" (603)
FLUSH INSET WIDTH**

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Dimension provides minimum reveals.

wolfappliance.com | 97
Vacuum Seal Drawer

Vacuum Seal Drawer


DRAWER FRONTS

STAINLESS STEEL BLACK GLASS INTEGRATED

98 | Wolf Customer Care 800.222.7820


Vacuum Seal Drawer

Dimensions
VACUUM SEAL DRAWER DRAWER FRONT

5 1/2" 5 1/2"
(140) (140)

23 1/2" (597) 7/8" 21" (533) W


(22) BEHIND FRAME

DRAWER FRONT W

24" Drawer Front 231/2" (597)

30" Drawer Front 297/8" (759)

INTEGRATED DRAWER FRONT


DRAWER 17"
FULL (432) A panel mounting kit is required when installing a custom
EXTENSION
panel.
IMPORTANT NOTE: A handle cannot be installed on the
custom panel.
The panel mounting kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.

wolfappliance.com | 99
Vacuum Seal Drawer

Planning Information
The Vacuum Seal Drawer can be installed in a standard or FILLER
flush inset application. Finish the edges of the opening.
A filler is required if installed below a countertop. The lid
They may be visible when the drawer is open.
is designed to remain open at 60°. Refer to the illustration
For standard installations, face trim will overlap stiles and below.
rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
2" (51)

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN


60° 2" (51) FILLER
Vacuum Seal Drawer 75 lb (34 kg)

TRIM OVERLAP
Top 0" (0)
Bottom 0" (0)
Sides 11/16" (18)

Filler

100 | Wolf Customer Care 800.222.7820


Vacuum Seal Drawer

Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 10 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 3' (.9 m)

wolfappliance.com | 101
Vacuum Seal Drawer

Vacuum Seal Drawer


STANDARD INSTALLATION

22 1/2"
(572)
OPENING
DEPTH

TOP VIEW

ANTI-TIP BLOCK

5 9/16" (141) E
OPENING HEIGHT

22 1/8" (562)
OPENING WIDTH

SIDE VIEW FRONT VIEW

102 | Wolf Customer Care 800.222.7820


Vacuum Seal Drawer

Vacuum Seal Drawer


FLUSH INSET INSTALLATION

23 1/2" (597)
FLUSH
INSET
7/8" (22)** DEPTH
FINISHED
CLEATS*

TOP VIEW

1/16" (2)
ANTI-TIP BLOCK

5 3/4" (146) E 1/8" (3)


FLUSH INSET HEIGHT***
A

W
FLUSH INSET WIDTH***

SIDE VIEW FRONT VIEW

*Will be visible and should be finished to match cabinetry.


**Cleat depth assumes a stainless steel, black glass, or 3/4" (19) custom panel.
***Dimension provides minimum reveals.

FLUSH INSET WIDTH W A

24" Opening 233/4" (603) 13/16" (21)

30" Opening 301/8" (765) 4" (102)

wolfappliance.com | 103
Dual Fuel Ranges

Dual Fuel Ranges


CONFIGURATIONS
30" RANGE 48" RANGE 60" RANGE

DF30450/S/P DF48850/S/P DF60650CG/S/P

36" RANGE DF48650C/S/P DF60650DG/S/P

DF36650/S/P DF48650G/S/P DF60650F/S/P

DF36450C/S/P DF48450CG/S/P

DF36450G/S/P DF48450DG/S/P

DF48450F/S/P

104 | Wolf Customer Care 800.222.7820


Dual Fuel Ranges

Dual Fuel Ranges 29 1/2" (749) 29 1/2" (749)


26 7/8" (683) 26 7/8" (683)
30" RANGE 36" RANGE 24" (610) 48" RANGE 24" (610)

36 1/2" 35 1/2" 36 1/2" 35 1/2" 36 1/2" 35 1/2"


(927) (902)* (927) (902)* (927) (902)*

29 7/8" (759) 35 7/8" (911) 26" (660) 26" (660)


47 7/8" (1216)
47 1/4" (1200) 47 1/4" (1200)
*35 1/2" (902) MIN TO 38" (965) MAX *35 1/2" (902) MIN TO 38" (965) MAX *

29
291/12/"2"(749)
(749)
26
267/78/"8(683)
" (683)
60" RANGE 24"
24"(610)
(610)

36
361/12/"2" 35
351/12/"2"
(927)
(927) (902)*
(902)*

59
597/78/"8"(1521)
(1521) 26"
26"(660)
(660)
47
471/14/"4(1200)
" (1200)
*35
*351/12/"2(902)
" (902)MIN TO38"
MINTO 38"(965)
(965)MAX
MAX

SIDE VIEW—ALL RANGES

wolfappliance.com | 105
Dual Fuel Ranges

Planning Information
IMPORTANT NOTE: When installing against a combustible GAS SUPPLY
surface, a minimum 10" (254) riser is required for a 36" dual
Installation must comply with all applicable gas codes.
fuel range with charbroiler or griddle and all 48" and 60"
models. Follow all minimum clearances to combustible If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
surfaces shown in the illustration on the following page. (19) ID flexible metal appliance connector is recommended.

A Wolf Pro Ventilation Hood is recommended with the Wolf natural gas ranges will function up to 10,250' (3124 m)
Dual Fuel Range. Refer to page 148 for Pro Ventilation. in altitude without adjustment and LP gas ranges will func-
tion up to 8,600' (2621 m). If the installation exceeds these
elevations, contact an authorized Wolf dealer for a high
ELECTRICAL REQUIREMENTS
altitude conversion kit.
Installation must comply with all applicable electrical codes.
GAS REQUIREMENTS
Locate the electrical supply flush with the wall or floor
and within the shaded area shown in the illustration on Gas Supply 3/4" ID line
the following page. A separate circuit servicing only this Gas Inlet 1/2" NPT female
appliance is required.
NATURAL GAS WC
If a power supply cord is used, the cord must be designated Supply Pressure 5" (12.5 mb)
for use with ranges and rated for 240 V, 30 or 50 amps Min Line Pressure 7" (17.5 mb)
(refer to the chart below), and must include 3 or 4 conduc- Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
tors. A 4-conductor cord is required for installations where LP GAS WC
grounding through the neutral is prohibited. Supply Pressure 10" (25 mb)
Performance may be compromised if the electrical supply Min Line Pressure 11" (27.4 mb)
is less than 240 volts. Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

ELECTRICAL REQUIREMENTS—SINGLE OVEN

Electrical Supply grounded, 240/208 VAC, 60 Hz

Service 30 amp dedicated circuit

Total Amps 21

Max Connected Load 5.2 kW

ELECTRICAL REQUIREMENTS—DOUBLE OVEN

Electrical Supply grounded, 240/208 VAC, 60 Hz

Service 50 amp dedicated circuit

Total Amps 42.5

Max Connected Load 10.2 kW

106 | Wolf Customer Care 800.222.7820


Dual Fuel Ranges

Dual Fuel Range


INSTALLATION

13" 18" 30" (762) TO 36" (914)


(330) (457) TO BOTTOM OF
VENTILATION HOOD*

6"
(152)

W
OPENING WIDTH

ELECTRICAL
AND GAS IN A 8 1/2"
‘A’ LOCATION (216)
ONLY 4 7/8" E G
(124)
2"
(51) SIDE VIEW FRONT VIEW

*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.

OPENING WIDTH W A

30" Range 30" (762) 101/4" (260)

36" Range 36" (914) 161/4" (413)

48" Range 48" (1219) 181/4" (464)

60" Range 60" (1524) 181/4" (464)

wolfappliance.com | 107
Gas Ranges

Gas Ranges
CONFIGURATIONS
30" RANGE 48" RANGE 60" RANGE

GR304 GR488 GR606DG

36" RANGE GR486C GR606CG

GR366 GR486G

GR364C GR484CG

GR364G GR484DG

108 | Wolf Customer Care 800.222.7820


Gas Ranges

28 3/8" (721) 28 3/8" (721)

27" (686) 27" (686)


56" (1422) 56" (1422)

9 1/4" 9 1/4"
Gas Ranges (235)
46" (1168)
(235)
46" (1168)

30" RANGE 36" RANGE 41" 48"


(1041)
RANGE 41" (1041)

37" 36" 25 3/8" (645) 37" 37" 36" 25 3/8" (645) 37" 37" 36"
(940)* (914) (940)* (940)* (914) (940)*(940)* (914)

2 1/2" 2 1/2" 2 1/2"


(64) (64) (64)

29 7/8" (759) 35 7/8" (911) 43 3/8" (1102) 47 7/8" (1216)


43 3/8" (1102)

*37" (940) MIN TO 38" (965) MAX. *37" (940) MIN TO 38" (965) MAX.
28 3/8" (721)

27" (686)
56" (1422)

9 1/4"
(235)
46" (1168)

60" RANGE 41" (1041)

37" 36" 25 3/8" (645) 37"


(940)* (914) (940)*

2 1/2"
(64)

60 1/8" (1527) 43 3/8" (1102)

*37" (940) MIN TO 38" (965) MAX.

SIDE VIEW—ALL RANGES

wolfappliance.com | 109
Gas Ranges

Planning Information
When installing against a combustible surface, a minimum GAS SUPPLY
20" (508) riser is required. Follow all minimum clearances
Installation must comply with all applicable gas codes.
to combustible surfaces shown in the illustration on the
following page. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
A Wolf Pro Ventilation Hood is recommended with the Gas
Range. Refer to page 148 for Pro Ventilation. Wolf natural gas ranges will function up to 8,600' (2621 m)
in altitude without adjustment. If the installation exceeds
this elevation, contact an authorized Wolf dealer for a high
ELECTRICAL REQUIREMENTS
altitude conversion kit. LP models do not require conver-
Installation must comply with all applicable electrical codes. sion.
Locate the electrical supply flush with the wall or floor and
GAS REQUIREMENTS
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance Gas Supply 3/4" ID line
is required. Gas Inlet 1/2" NPT female

NATURAL GAS WC
ELECTRICAL REQUIREMENTS
Supply Pressure 5" (12.5 mb)
Electrical Supply grounded, 110/120 VAC, 60 Hz Min Line Pressure 7" (17.5 mb)
Service 15 amp dedicated circuit Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

LP GAS WC
Receptacle 3-prong grounding-type
Supply Pressure 10" (25 mb)
Power Cord 6' (1.8 m) Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

110 | Wolf Customer Care 800.222.7820


Gas Ranges

Gas Range
INSTALLATION

13" 18" 30" (762) TO 36" (914)


(330) (457) TO BOTTOM OF
VENTILATION HOOD*

6"
(152)

W
OPENING WIDTH

12" 10" (254)


(305)

5 3/4" E
(146)
LOCATION OF GAS AND
ELECTRICAL EXTENDS
ON FLOOR 7 3/4" (197) 2" (51)
G
3" 12" 5"
(76) SIDE VIEW FRONT VIEW (305) GAS (127)

*Without ventilation hood, 42" (1067) minimum clearance countertop to combustible materials, charbroiler and GR488 require non-combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.

OPENING WIDTH W

30" Range 30" (762)

36" Range 36" (914)

48" Range 48" (1219)

60" Range 601/4" (1530)

wolfappliance.com | 111
Induction Ranges

Induction Ranges
CONFIGURATIONS
TRANSITIONAL

IR30450/S/T IR36550/S/T

PROFESSIONAL

IR30450/S/P IR36550/S/P

112 | Wolf Customer Care 800.222.7820


Induction Ranges

Induction Ranges
28 1/4" (718) 28 1/4" (718)
30" TRANSITIONAL 36" TRANSITIONAL
27 1/2" (699) 27 1/2" (699)
24 1/4" (616) 24 1/4" (616)

35 1/2" 35 1/2"
(902)* (902)*

29 7/8" (759) 35 7/8" (911)26 1/4" (667) 26 1/4" (667)


47 1/4" (1200) 47 1/4" (1200)
*35 1/2" (902) MIN TO 38" (965) MAX *35 1/2" (902) MIN TO 38" (965) MAX

SIDE VIEW—TRANSITIONAL

29 /2" (749)1 29 1/2" (749)


30" PROFESSIONAL 36" PROFESSIONAL
27 1/2" (699) 27 1/2" (699)
24 1/4" (616) 24 1/4" (616)

35 1/2" 35 1/2"
(902)* (902)*

29 7/8" (759) 35 7/8" (911)26 1/4" (667) 26 1/4" (667)


47 1/4" (1200) 47 1/4" (1200)
*35 1/2" (902) MIN TO 38" (965) MAX *35 1/2" (902) MIN TO 38" (965) MAX

SIDE VIEW—PROFESSIONAL

wolfappliance.com | 113
Induction Ranges

Planning Information
Follow all minimum clearances to combustible surfaces ELECTRICAL REQUIREMENTS
shown in the illustration on the following page.
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors. A 4-conductor cord
is required for installations where grounding through the
neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 240/208 VAC, 60 Hz

Service 50 amp dedicated circuit

114 | Wolf Customer Care 800.222.7820


Induction Ranges

Induction Range
INSTALLATION

13" 18" 30" (762) TO 36" (914)


(330) (457) TO BOTTOM OF
VENTILATION HOOD*

6"
(152)

W
OPENING WIDTH

ELECTRICAL IN A 8 1/2"
‘A’ LOCATION (216)
ONLY 4 7/8" E
(124)
2"
(51) SIDE VIEW FRONT VIEW

*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.

OPENING WIDTH W A

30" Range 30" (762) 101/4" (260)

36" Range 36" (914) 161/4" (413)

wolfappliance.com | 115
Sealed Burner Rangetops

Sealed Burner Rangetops


CONFIGURATIONS
30" RANGETOP 36" RANGETOP 48" RANGETOP

SRT304 SRT366 SRT486C

SRT364C SRT486G

SRT364G SRT484CG

SRT362W SRT484DG

SRT484W

116 | Wolf Customer Care 800.222.7820


Sealed Burner Rangetops

28 1/2" (724)
27 1/2" (699)

9 1/4"
Sealed Burner Rangetops (235)
17 1/2" (445)

30" RANGETOP 12 1/2" (318)

8 1/2" 7 1/2" 24 1/8" (613) 8 1/2"


(216) (191) (216)

29 7/8" (759) 26 1/8" (664)

28 1/2" (724)
27 1/2" (699)

9 1/4"
36" RANGETOP (WOK MODEL SHOWN) (235) 17 1/2" (445)
11/2" (38)
12 1/2" (318)

8 1/2" (216) 7 1/2" 24 1/8" (613) 8 1/2"


(191) (216)

35 7/8" (911) 26 1/8" (664)


28 1/2" (724)
27 1/2" (699)

9 1/4"
(235)
17 1/2" (445)

48" RANGETOP 12 1/2" (318)

8 1/2" 7 1/2" 24 1/8" (613) 8 1/2"


(216) (191) (216)

47 7/8" (1216) 26 1/8" (664)

SIDE VIEW—ALL RANGETOPS

wolfappliance.com | 117
Sealed Burner Rangetops

Planning Information
The platform to support the Sealed Burner Rangetop must ELECTRICAL REQUIREMENTS
include a cutout for electrical and gas supply connections.
Installation must comply with all applicable electrical codes.
Refer to the chart below for minimum base support.
Locate the electrical supply within the shaded area shown
When installing against a combustible surface, a mini-
in the illustration on the following page. A separate circuit
mum 5" (127) riser is required for model SRT366, and a
servicing only this appliance is required.
minimum 10" (254) riser is required for 36" and 48" Sealed
Burner Rangetops with a charbroiler or griddle. Follow all
ELECTRICAL REQUIREMENTS
minimum clearances to combustible surfaces shown in
the illustration on the following page. Models SRT362W Electrical Supply grounded, 110/120 VAC, 60 Hz
and SRT484W cannot be installed against a combustible Service 15 amp dedicated circuit
surface.
Receptacle 3-prong grounding-type
A Wolf Pro Ventilation Hood is recommended with
Power Cord 6' (1.8 m)
the sealed burner rangetop. Refer to page 148 for Pro
Ventilation.
A downdraft can be used with Models SRT304 and SRT366. GAS SUPPLY
An accessory trim kit is necessary for this installation. Con- Installation must comply with all applicable gas codes.
tact an authorized Wolf dealer for details.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN Wolf natural gas rangetops will function up to 10,250'
30" Rangetop 200 lb (91 kg) (3124 m) in altitude without adjustment and LP gas ran-
36" Rangetop 250 lb (113 kg) getops up to 8,600' (2621 m). If the installation exceeds
48" Rangetop 300 lb (136 kg) these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
PLATFORM MIN
Thickness 3/4" (19)
GAS REQUIREMENTS

Gas Supply 3/4" ID line

Gas Inlet 1/2" NPT female

NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

118 | Wolf Customer Care 800.222.7820


Sealed Burner Rangetops

Sealed Burner Rangetop


INSTALLATION

13" 18" 30" (762) TO 36" (914)


(330) (457) TO BOTTOM OF
VENTILATION HOOD*

6"
(152)

7 1/2" (191)
OPENING W
HEIGHT OPENING WIDTH

24" (610) MAX PLATFORM


PLATFORM PLATFORM
TOP VIEW
4"
(102) BACK WALL

E G
16" (406)
ELECTRICAL
AND GAS

SIDE VIEW FRONT VIEW

*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical and gas supply located through bottom of platform.
For island installation, 12" (305) minimum clearance back of rangetop to combustible rear wall above countertop.

OPENING WIDTH W

30" Rangetop 30" (762)

36" Rangetop 36" (914)

48" Rangetop 48" (1219)

wolfappliance.com | 119
Outdoor Grills/Modules

Outdoor Grills and Modules


OUTDOOR GRILLS

OG30 OG36 OG42

OG54

OUTDOOR MODULES

BM13 SB13
BURNER MODULE SIDE BURNER

120 | Wolf Customer Care 800.222.7820


Outdoor Grills/Modules

Outdoor Grills and Modules


OUTDOOR GRILL 30" (762)
HOOD CLOSED

27"
(686)

12 1/2" (318) 2 1/2"


(64)
TO GRILLING
CLEARANCE
SURFACE
FOR OPEN
HOOD

W 27 3/4" (705)
WIDTH

GRILL CART

12"
(305)

36 1/2"
24" (610) (927)
TO GRILL
PLATFORM

3" (76)

W 27 3/4" (705)
WIDTH

MAX DOOR/DRAWER CLEARANCE 22" (559)

BURNER MODULE / SIDE BURNER OUTDOOR GRILL W

OG30 30" (762)


30" (762)
OG36 36" (914)

OG42 42" (1067)


10 3/4" (273)
OG54 54" (1372)

13" 27 3/4" (705)


(330) GRILL CART W

CART30 30" (762)

CART36 36" (914)

CART42 42" (1067)

wolfappliance.com | 121
Outdoor Grills/Modules

Planning Information
For portable applications, Wolf grill carts are designed ELECTRICAL REQUIREMENTS
specifically to fit Grill Models OG30, OG36, and OG42
Installation must comply with all applicable electrical codes.
and the Side Burner. Model OG54 is designed for built-in
applications only. The electrical outlet must be located within reach of the
power cord. A separate circuit servicing only this appli-
For built-in applications, Wolf Outdoor Grills and the
ance is required. A ground fault circuit interrupter (GFCI) is
Burner Module are designed for easy placement into
required to reduce the risk of electrical shock.
a built-in enclosure. For outdoor grills, installation in a
combustible enclosure requires an insulating liner. For
ELECTRICAL REQUIREMENTS
the Burner Module, an insulating liner is not required.
The enclosure should be built according to specifica- Electrical Supply grounded, 120 VAC, 60 Hz
tions for your specific installation on the following pages. Service 15 amp dedicated circuit
If the Burner Module is installed next to an Outdoor Grill,
Receptacle 3-prong grounding-type, GFCI
a minimum of 12" (305) is required between the units on
the rotisserie motor side and 2" (51) on the opposite side. A Power Cord 6' (1.8 m)
rotisserie side conversion kit is available from an authorized
Wolf dealer.
Model BM13 does not include a tank retention system and
cannot be connected to a portable LP tank.
Optional stainless steel accessory doors and drawers are
available for built-in applications. Refer to pages 126–130.
Grill carts, insulating liners, and stainless steel doors and
drawers are avail­able through an authorized Wolf dealer.
For local dealer information, visit the find a showroom sec-
tion of our website, wolfappliance.com.

122 | Wolf Customer Care 800.222.7820


Outdoor Grills/Modules

GAS SUPPLY GAS REQUIREMENTS

Installation must comply with all applicable gas codes. Gas Supply 3/4" ID line

If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" Gas Inlet 1/2" NPT female
(19) ID flexible metal appliance connector is recommended. NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
If the Outdoor Grill is being connected to a whole house
Min Line Pressure 7" (17.5 mb)
LP supply, the LP gas pressure regulator is not provided.
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
It can be purchased from an authorized Wolf dealer. For
local dealer information, visit the find a showroom section LP GAS WC
of our website, wolfappliance.com. Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

wolfappliance.com | 123
Outdoor Grills/Modules

Outdoor Grill
NON-COMBUSTIBLE INSTALLATION COMBUSTIBLE INSTALLATION

12" (305)
2 1/2" (64)

10 3/4"
13" G (273) C
24 1/4" (616) (330) TRIM 26" (660) L TRIM
OPENING OVERLAP OPENING G CL OVERLAP
DEPTH DEPTH 2 3/4" (70)
31/2" KNOCKOUT
5"
(127)
(89)
6" 12"
(152) (305)

TOP VIEW TOP VIEW

W W
OPENING WIDTH OPENING WIDTH

11 3/4" 6" 12 5/8"


(298) (152) (321)
OPENING OPENING
HEIGHT 4" (102) G HEIGHT

13/16" 13/16"
(21) (21)

OPENING OPENING

COUNTERTOP COUNTERTOP
OVERHANG OVERHANG

FRONT VIEW FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to NOTE: Shaded area above countertop indicates minimum clearance to
combustible surfaces, combustible materials cannot be located within this area. combustible surfaces, combustible materials cannot be located within this area.

NON-COMBUSTIBLE ENCLOSURE W COMBUSTIBLE ENCLOSURE W

OG30 281/2" (724) OG30 331/2" (851)

OG36 341/2" (876) OG36 391/2" (1003)

OG42 401/2" (1029) OG42 451/2" (1156)

OG54 521/2" (1334) OG54 571/2" (1461)

124 | Wolf Customer Care 800.222.7820


Outdoor Grills/Modules

Burner Module
INSTALLATION

12" (305)

G 3" (76)

24 1/4" (616) MODULE


OPENING OVERLAP
DEPTH

6"
(152)

TOP VIEW

12" (305)
OPENING

10" (254)
OPENING 8"
G (203)
HEIGHT

7"
(178)

9/16"
(14)

MODULE
OPENING

COUNTERTOP
OVERHANG

FRONT VIEW

NOTE: Shaded area above countertop indicates minimum clearance to


combustible surfaces, combustible materials cannot be located within this area.
An insulating liner is not required.

wolfappliance.com | 125
Outdoor Accessories

Outdoor Accessories
ACCESS DOORS ACCESSORY DRAWERS AND DOORS

SINGLE DRAWER

SINGLE DOUBLE 2- OR 3-DRAWER DOOR/DRAWER

PAPER TOWEL DRAWER

SHORT DRY STORAGE

TALL DRY STORAGE

TRASH/RECYCLING
DRAWER

126 | Wolf Customer Care 800.222.7820


Outdoor Accessories

Access Doors
DIMENSIONS INSTALLATION

B 3 1/2" (89)
FINISHED
RETURN

2 3/4" (70)
W
TOP VIEW
A GRILL OPENING
1" (25) min

19" (483)
20 3/4" 18 3/4" OPENING
(527) (476) HEIGHT

W
OPENING WIDTH

DOOR WIDTH A B
FRONT VIEW
18" Single 18" (457) 161/4" (413)

30" Double 30" (762) 281/4" (718)


OPENING WIDTH W
36" Double 36" (914) 341/4" (870)
18" Single 161/2" (419)
42" Double 42" (1067) 401/4" (1022)
30" Double 281/2" (724)
54" Double 54" (1372) 521/4" (1327)
36" Double 341/2" (876)

42" Double 401/2" (1029)

54" Double 521/2" (1334)

IMPORTANT NOTE: The opening dimensions provided are


for a standard installation. For a flush installation, refer to
the overall dimensions and adjust the opening dimensions
accordingly.

wolfappliance.com | 127
Outdoor Accessories

Accessory Drawers and Doors


SINGLE DRAWER 2- OR 3-DRAWER

27" (686) 12" (305)

24" 18"
(610) (457)

2 3/4" (70) 2 3/4" (70)

30" (762) 13" (330)

11 3/8" 9 1/2"
(289) (241)
20 3/4" 19"
(527) (483)

PAPER TOWEL DRAWER

14 1/2" (368)
DRAWER/DOOR

28 1/2" (724)
19"
(483)

18"
2 3/4" (70) (457)

18" (457)

2 3/4" (70)
10" 8"
(254) (203) 30" (762)

20 3/4" 19"
(527) (483)

128 | Wolf Customer Care 800.222.7820


Outdoor Accessories

Accessory Drawers and Doors


TALL DRY STORAGE TRASH/RECYCLING DRAWER

22" (559) 16" (406)

19 3/4"
(502)
D

2 3/4" (70)

2 3/4" (70)
24" (610)

18" (457)

26" 24"
34" 32" (660) (610)
(864) (813)

SHORT DRY STORAGE DEPTH D

Single 191/2" (495)


34" (864)
Double 221/2" (572)

19 3/4"
(502)

2 3/4" (70)

36" (914)

20 3/4" 18 3/4"
(527) (476)

wolfappliance.com | 129
Outdoor Accessories

Accessory Drawers and Doors


INSTALLATION

OPENING W H D

Single Drawer 271/4" (692) 93/4" (248) 241/4" (616)

Paper Towel Drawer 143/4 (375) 81/4" (210) 191/4" (489)

2- or 3-Drawer 121/4" (311) 191/4" (489) 181/4" (464)


D Drawer/Door 283/4" (730) 191/4" (489) 181/4" (464)
OPENING
DEPTH
Tall Dry Storage 221/4" (565) 321/4" (819) 20" (508)

Short Dry Storage 341/4" (870) 19" (483) 20" (508)

Single Trash/Recycling 161/4" (413) 241/4" (616) 193/4" (502)


TOP VIEW
Double Trash/Recycling 161/4" (413) 241/4" (616) 223/4" (578)
W
OPENING WIDTH
BASE SUPPORT MIN
1" (25) min
2- or 3-Drawer 150 lb (68 kg)

Drawer/Door 150 lb (68 kg)

H Dry Storage 300 lb (136 kg)


OPENING
HEIGHT

IMPORTANT NOTE: The opening dimensions provided are


3 1/2" (89) for a standard installation. For a flush installation, refer to
FINISHED
RETURN the overall dimensions and adjust the opening dimensions
accordingly.
W
FRONT VIEW

130 | Wolf Customer Care 800.222.7820


Outdoor Accessories

wolfappliance.com | 131
Cooktop Ventilation Hoods

Cooktop Hoods
MODELS
BLACK

VW30B WALL VW36B WALL VW45B WALL

VI42B ISLAND

STAINLESS

VW30S WALL VW36S WALL VI42S ISLAND

GLASS

VW36G WALL VW45G WALL VI45G ISLAND

132 | Wolf Customer Care 800.222.7820


Cooktop Ventilation Hoods

Cooktop Hoods
WALL HOODS—BLACK

11 3/4" 10 1/4"
(298) (260)

29 1/8" (740)
TO 211/4"
39 1/4" (997)* (540)

21/4" (57)

W 19 1/4"
WIDTH (489)

*49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension.

WIDTH W

VW30B 30" (762)

VW36B 36" (914)

VW45B 45" (1143)

ISLAND HOOD—BLACK

13 3/4" 111/4"
(349) (286)

23 5/8" (600)
TO 23 1/4"
32" (813)* (591)

21/4" (57)

42" 26 1/2"
(1067) (673)

*51 1/8" (1299) to 59 1/2" (1511) with accessory flue extension.

wolfappliance.com | 133
Cooktop Ventilation Hoods

Cooktop Hoods
WALL HOODS—STAINLESS

11 3/4" 10 1/4"
(298) (260)

29 1/8" (740) 211/4"


TO (540)
39 1/4" (997)*

6"
(152)

W 22"
WIDTH (559)

*49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension.

WIDTH W

VW30S 30" (762)

VW36S 36" (914)

ISLAND HOOD—STAINLESS

13 3/4" 111/4"
(349) (286)

23 5/8" (600) 23 1/4"


TO (591)
32" (813)*

6"
(152)

42" 26 1/2"
(1067) (673)

*51 1/8" (1299) to 59 1/2" (1511) with accessory flue extension.

134 | Wolf Customer Care 800.222.7820


Cooktop Ventilation Hoods

Cooktop Hoods
WALL HOODS—GLASS

11 3/4" 10 1/4"
(298) (260)

29 1/8" (740)
TO 211/4"
39 1/4" (997)* (540)

21/4" (57)

W 19 1/4"
WIDTH (489)

*49 1/8" (1248) to 59 1/4" (1505) with accessory flue extension.

WIDTH W

VW36G 36" (914)

VW45G 45" (1143)

ISLAND HOOD—GLASS

13 3/4" 111/4"
(349) (286)

23 5/8" (600)
TO 23 1/4"
32" (813)* (591)

21/4" (57)

45" 26 1/2"
(1143) (673)

*51 1/8" (1299) to 59 1/2" (1511) with accessory flue extension.

wolfappliance.com | 135
Cooktop Ventilation Hoods

Planning Information
Wolf Cooktop Ventilation Hoods are recommended for ELECTRICAL REQUIREMENTS
use with Wolf Induction, Electric and Gas Cooktops, and
Installation must comply with all applicable electrical codes.
Modules. For Wolf Ranges and Rangetops, a Pro Ventilation
Hood is recommended. For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. For island
These hoods have a telescopic chimney flue. A flue exten-
hoods, locate the electrical supply on the ceiling inside the
sion is available through an authorized Wolf dealer.
top of the hood. A separate circuit servicing only this appli-
Installation of the cooktop hood should be 24" (610) to ance is required.
36" (914) from the bottom of the hood to the countertop.
ELECTRICAL REQUIREMENTS
Wall and island hoods require an internal, in-line, or remote
blower assembly, avail­able through an authorized Wolf Electrical Supply grounded, 110/120 VAC, 60 Hz
dealer. For local dealer information, visit the find a show- Service 15 amp dedicated circuit
room section of our website, wolfappliance.com. Refer to
Ventilation Suggestions on pages 154–157. Cooktop Hoods
have a vertical discharge with 6" (152) round duct.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications. LOCATE
ELECTRICAL
WITHIN
SHADED AREA E

20"
(508)

24" (610) TO 36" (914) BOTTOM EDGE TO COUNTERTOP

Electrical location for all wall hoods

136 | Wolf Customer Care 800.222.7820


Cooktop Ventilation Hoods

Ceiling-Mounted Hood
The Ceiling-Mounted Hood is our most contemporary CEILING-MOUNTED HOOD
ventilation offering, nearly disappearing into its surround- STAINLESS STEEL
ings. It comes in two widths and is available in stainless
steel or white glass. The hood ships with a remote control
and can be operated using the remote control or the con-
trol panel. The control panel is recessed into the right side
VC36S VC48S
of the hood. The dishwasher-safe filters can be removed
easily for cleaning.
WHITE GLASS

VC36W VC48W

wolfappliance.com | 137
Cooktop Ventilation Hoods

Ceiling-Mounted Hood
STAINLESS STEEL

A
13 1/4" 13 1/4"
(337) (337)

7 1/4" (184)
7 1/4" TO
(184)
12 3/4" (324)

5" (127)

W 1/16" (2) 21" (533)

DIMENSIONS W A

36" Hood 351/2" (902) 331/8" (841)

48" Hood 471/4" (1200) 441/8" (1121)

WHITE GLASS

A
13 1/4" 13 1/4"
(337) (337)

7 1/4" (184)
7 1/4" TO
(184)
12 3/4" (324)

5" (127)

W 1/4" (6) 21" (533)

DIMENSIONS W A

36" Hood 351/2" (902) 331/8" (841)

48" Hood 471/4" (1200) 441/8" (1121)

138 | Wolf Customer Care 800.222.7820


Cooktop Ventilation Hoods

Planning Information
Installation of the Ceiling-Mounted Hood should be 36" RECIRCULATING APPLICATION
(914) to 84" (2134) from the bottom of the hood to the
The Ceiling-Mounted Hood with an internal blower only,
countertop.
can be installed in a recirculating application. The air dis-
The hood can be operated using the remote control or the charge must be a minimum of 40" (1016) from every side of
control panel located on the right side of the hood. the hood. Refer to the illustration below. The ductwork and
vent cover are not provided. A recirculation kit, available
The hood is shipped without a blower assembly. Inter-
through an authorized Wolf dealer, is required.
nal, in-line, and remote blowers are avail­able through an
authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com. Refer to Ventilation Suggestions on
pages 154–157.
Ceiling-Mounted Hoods include a 6" (152) round discharge
for internal blowers and a 10" (254) round discharge for in-
line and remote blowers. For an internal blower, the blower
box can be rotated to discharge right, left, front, or rear.
For an in-line or remote blower, the discharge is vertical
only. 40" (1016)
MIN
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.

Recirculating application

wolfappliance.com | 139
Cooktop Ventilation Hoods

Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. Allow a minimum 12" (305)
Romex® wire for connection. A separate circuit servicing
only this appliance is required.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

36" (914) TO 84" (2134) BOTTOM EDGE TO COUNTERTOP

Electrical location

140 | Wolf Customer Care 800.222.7820


Cooktop Ventilation Hoods

Opening Dimensions
CEILING-MOUNTED HOOD
Refer to the chart and illustrations below for opening
dimensions and typical framing. Framing must be able to
support a minimum of 100 lb (45 kg).

HOOD W

36" Hood 341/2" (873)

48" Hood 461/4" (1175)

20"
(508) W

Opening dimensions

12 3/8" (314) MIN TO


17 3/4" (451) MAX

Support framing (typical)

wolfappliance.com | 141
Downdraft Ventilation

Downdraft Ventilation
MODELS

DD30 DD36

DD45

142 | Wolf Customer Care 800.222.7820


Downdraft Ventilation

Downdraft Ventilation
DIMENSIONS

W 2"
DOWNDRAFT WIDTH (51)

6 3/4"
(172)
14"
(356)

2 3/8"
(60)

15"
(381)
13" 28 3/4" 10"
(330) (730) (254)

13"
(330)

A 2 1/2"
CHIMNEY WIDTH (64)

NOTE: Shown with front mounted internal blower with 6" (152) round discharge,
dashed line represents rear mount.

WIDTH W A

DD30 30" (762) 261/2" (673)

DD36 36" (914) 321/2" (826)

DD45 45" (1143) 381/2" (978)

wolfappliance.com | 143
Downdraft Ventilation

Planning Information
Wolf Downdrafts can be installed with most Wolf cook- ELECTRICAL REQUIREMENTS
tops, but are not compatible with the Grill, Steamer, and
Installation must comply with all applicable electrical codes.
Fryer Modules. Downdrafts can be installed with Sealed
Burner Rangetop Models SRT304 and SRT366. Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
For installation with a Wolf cooktop, a minimum 251/8" (638)
this appliance is required. A ground fault circuit interrupter
deep flat countertop is required.
(GFCI) is not recommended and may cause interruption of
For installation with a Sealed Burner Rangetop or 30" (762) operation.
or 36" (914) contemporary cooktop, an accessory trim kit is
Certain installations may require the electrical supply be
required. Contact an authorized Wolf dealer for details. For
placed in an adjacent cabinet.
local dealer information, visit the find a showroom section
of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS
The remote-mounted control module can be positioned
Electrical Supply grounded, 120 VAC, 60 Hz
horizontally or vertically. It must be located within 9' (2.7 m)
of the downdraft assembly and a minimum 3" (76) from the Service 15 amp dedicated circuit
edge of the cooktop cutout. Receptacle 3-prong grounding-type

Consult a qualified HVAC professional for specific installa- Power Cord 21/2' (.8 m)
tion and ducting applications.

BLOWERS
Internal, in-line, and remote blowers are available through
an authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com. Refer to Ventilation Suggestions on
pages 154–157.
Internal blowers have a 6" (152) round discharge, can be
front or rear mounted, and can be discharged in any direc-
tion by rotating the blower box. In-line and remote blow-
ers have a 10" (254) discharge and can be discharged from
the front or rear.

144 | Wolf Customer Care 800.222.7820


Downdraft Ventilation

Downdraft
INSTALLATION WITH STANDARD INSTALLED COOKTOP

W
DOWNDRAFT
CUTOUT WIDTH

2 11/16" (68) E
8 1/4" (210)*

COOKTOP CUTOUT

TOP VIEW

8 1/4" 211/4" 211/4" 23 3/8"


(210)* (540) (540) (594)

SIDE VIEW FRONT VIEW

*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.

CUTOUT WIDTH W

DD30 271/2" (699)

DD36 331/2" (851)

DD45 391/2" (1003)

wolfappliance.com | 145
Downdraft Ventilation

Downdraft
INSTALLATION WITH FLUSH INSTALLED COOKTOP

W
DOWNDRAFT
CUTOUT WIDTH

2 5/16" (59) E
8 1/4" (210)*

COOKTOP CUTOUT

TOP VIEW

8 1/4" 211/4" 211/4" 23 3/8"


(210)* (540) (540) (594)

SIDE VIEW FRONT VIEW

*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.

CUTOUT WIDTH W

DD30 271/2" (699)

DD36 331/2" (851)

146 | Wolf Customer Care 800.222.7820


Downdraft Ventilation

Downdraft
INSTALLATION WITH SEALED BURNER RANGETOP

W
DOWNDRAFT
CUTOUT WIDTH

2 11/16" (68) E
8 1/4" (210)*

RANGETOP OPENING

TOP VIEW

19" (483)
PLATFORM DEPTH

211/4" 211/4" 23 3/8"


(540) (540) (594)
8 1/4"
(210)*

SIDE VIEW FRONT VIEW

*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.

CUTOUT WIDTH W

DD30 271/2" (699)

DD36 331/2" (851)

wolfappliance.com | 147
Pro Ventilation Hoods

Pro Hoods
MODELS
WALL HOODS

LOW-PROFILE 24"/27" DEEP

CHIMNEY OUTDOOR

ISLAND HOOD

ISLAND

HOOD LINER

19"/22" DEEP

148 | Wolf Customer Care 800.222.7820


Pro Ventilation Hoods

Pro Hoods
LOW-PROFILE WALL HOOD

12"
(305)

10" (254)
4" (102)

W 22" (559)
WIDTH

24" DEEP WALL HOOD


12"
(305)

18"
(457)

4" (102)

W 24" (610)
WIDTH

27" DEEP WALL HOOD


12"
(305)

18"
(457)

4" (102)

W 27" (686)
WIDTH

WIDTH
LOW-PROFILE WALL HOOD W
30" (762), 36" (914), 42" (1067), 48" (1219)

24" DEEP WALL HOOD W


30" (762), 36" (914), 42" (1067), 48" (1219)
54" (1372), 60" (1524), 66" (1676)

27" DEEP WALL HOOD W


30" (762), 36" (914), 42" (1067), 48" (1219)
54" (1372), 60" (1524), 66" (1676)

wolfappliance.com | 149
Pro Ventilation Hoods

Pro Hoods
WALL CHIMNEY HOOD

WIDTH MINUS 18" (457) 13 1/2"


(343)

18"
(457)

4" (102)

W 24" (610)
WIDTH

ISLAND HOOD

WIDTH MINUS 18" (457) 13"


(330)

18"
(457)

4" (102)

W 34" (864)
WIDTH

HOOD LINER

WIDTH MINUS 6" (152) 12"


(305)

12 1/8"
(308)
4" (102)

W 19 3/8" (492)
WIDTH 22 5/8" (575)

WIDTH
WALL CHIMNEY HOOD W
36" (914), 42" (1067), 48" (1219), 54" (1372)

ISLAND HOOD W
36" (914), 42" (1067), 54" (1372), 66" (1676)

HOOD LINER W
343/8" (873), 403/8" (1026), 463/8" (1178)
523/8" (1330), 583/8" (1483)

150 | Wolf Customer Care 800.222.7820


Pro Ventilation Hoods

Pro Hoods
OUTDOOR WALL HOOD

13 9/16"
(346)

18"
(457)

4" (102)

W 33" (838)
WIDTH

WIDTH
OUTDOOR WALL HOOD W
36" (914), 48" (1219), 60" (1524)

wolfappliance.com | 151
Pro Ventilation Hoods

Planning Information
Pro Ventilation Hoods and hood liners are recommended RECIRCULATING APPLICATION
for use with all Wolf cooking appliances. Wall hoods should
Low-profile, 24" deep, and 27" deep wall hoods with an
be at least as wide as the cooking surface and island hoods
internal blower (600 CFM or less), 30" (762) and 36" (914)
should be 3" (76) wider on each side.
widths only, can be used in a non-ducted application with
For optimal performance in wall hood applications, a Pro a recirculating filter. In this installation, kitchen air is puri-
27" deep wall hood is recommended for use with ranges fied through the filters and returned as clean air into the
and rangetops with a charbroiler or griddle. room. A recirculation kit, available through an authorized
Wolf dealer, is required.
Installation of all Pro Hoods except the outdoor wall hood
should be 30" (762) to 36" (914) from the bottom of the
hood to the countertop. Installation of the outdoor wall CUSTOM HOOD APPLICATIONS
hood should be 36" (914) to 42" (1067) from the bottom of
Wolf Pro hood liners are for use in custom hood applica-
the hood to the countertop.
tions. The decorative hood can be created out of wood,
Pro Hoods and hood liners are shipped without a blower plaster, tile, or metal. The shape of the hood is not critical,
assembly. Internal, in-line, and remote blowers are avail- however, the bottom of the hood and liner must be on
able through an authorized Wolf dealer. For local dealer the same plane. The height of the liner does not need to
information, visit the find a showroom section of our accommodate the entire height of the decorative hood.
website, wolfappliance.com. The blower will vary in size
and is dictated by the cooking unit, volume of air, and
ELECTRICAL REQUIREMENTS
length of the duct run. Refer to Ventilation Suggestions
on pages 154–157. Installation must comply with all applicable electrical codes.

Pro Hoods accommodate a 10" (254) round duct. Low- Locate the electrical supply as shown in the illustrations
profile wall hoods allow for an adjustable discharge. All on the following page. A separate circuit servicing only this
other Pro Hoods have a vertical discharge. For the 24" and appliance is required.
27" deep wall hoods, a horizontal discharge kit is available For the outdoor wall hood, a ground fault circuit inter-
through an authorized Wolf dealer. rupter (GFCI) is required to reduce the risk of electrical
Consult a qualified HVAC professional for specific installa- shock.
tion and ducting applications.
ELECTRICAL REQUIREMENTS
Optional stainless steel duct covers in a variety of heights
are available for Pro wall and island hoods through an Electrical Supply grounded, 120 VAC, 60 Hz
authorized Wolf dealer. Service 15 amp dedicated circuit

152 | Wolf Customer Care 800.222.7820


Pro Ventilation Hoods

Installation
LOW-PROFILE / 24" DEEP / 27" DEEP WALL HOOD OUTDOOR WALL HOOD

6" 6"
E (152) E (152)

5" 5"
(127) (127)

30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP 36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP

WALL CHIMNEY HOOD

6"
E (152)

5"
(127)

30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP

ISLAND HOOD

ELECTRICAL LOCATION
THROUGH TOP OF HOOD

30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP

HOOD LINER

DECORATIVE HOOD

E
121/2" 75/8"
(318) (194)

30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP

wolfappliance.com | 153
Ventilation Suggestions

Blower Assemblies
For Wolf Ventilation Hoods and Downdrafts that do not Ventilation suggestions on the following pages provide
include a blower assembly, an internal, in-line, or remote Wolf product CFM and blower options for each Ventilation
blower assembly must be selected to accommodate the Hood and Downdraft.
cooking appliance, CFM requirements, and homeowner
Refer to the illustrations below for dimensions of Wolf in-
preferences. Internal, in-line, and remote blowers are avail­
line and remote blowers. Installation instructions shipped
able through an authorized Wolf dealer. For local dealer
with each Wolf ventilation product provide detailed
information, visit the find a showroom section of our
specifications. These instructions can also be found on our
website, wolfappliance.com.
website, wolfappliance.com/specs.

600 CFM IN-LINE 1100 CFM IN-LINE

24 3/8" 24 7/8"
(619) (632)

11 3/4"
(298) 18"
(457) 12"
18 1/2" (305)
(470)

4 1/2"
(114)
8"
(203)
211/2"
(546) 12 1/4"
(311) 22" 18"
(559) (457)

600 / 900 CFM REMOTE 1500 CFM REMOTE

21" (533)

20 3/4" 10"
(254)
28 1/4"
(527) 29 1/2"
(718) (749)
10" (254) 10" (254)
DIAMETER DIAMETER

15 1/2" 14 3/4"
(375) 29 1/2"
(394) 24 1/2" (749)
(622)

10 3/8"
14" (264)
(356)
4 3/4"
24 3/4" (121) 25" 7 1/4"
(629) (635) (184)

154 | Wolf Customer Care 800.222.7820


Ventilation Suggestions

Wolf Product CFM

CFM COOKTOP HOOD DOWNDRAFT PRO HOOD


COOKTOP / MODULE

CI152TF/S CG152TF/S 300 600 300

SM15TF/S FM15TF/S GM15TF/S 300 300

TM15TF/S MM15TF/S 300 600 300

CI243TF/S CI243C/B CG243TF/S 300 300

CI30460T/S CI30460C/B CI304TF/S CI304T/S CI304C/B 300 600 300

CE304T/S CE304C/B 300 600 300

CG304T/S CG304P/S 300 600 300

CI36560T/S CI36560C/B CI365TF/S CI365T/S CI365C/B 300 600 300

CE365T/S CE365C/B 300 600 300

CG365T/S CG365P/S CG365C/S 300 600 300

DUAL FUEL RANGE

DF30450/S/P 500

DF36650/S/P DF36450C/S/P DF36450G/S/P 800

DF48850/S/P DF48650C/S/P DF48650G/S/P DF48450CG/S/P


DF48450DG/S/P DF48450F/S/P 1100

DF60650CG/S/P DF60650DG/S/P DF60650F/S/P 1500

GAS RANGE

GR304 500

GR366 GR364C GR364G 800

GR488 GR486C GR486G GR484CG GR484DG 1100

GR606CG GR606DG 1500

INDUCTION RANGE

IR30450/S/T IR30450/S/P 300 300

IR36550/S/T IR36550/S/P 300 300

SEALED BURNER RANGETOP

SRT304 600 500

SRT366 600 800

SRT364C SRT364G SRT362W 800

SRT486C SRT486G SRT484CG SRT484DG SRT484W 800

Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.

wolfappliance.com | 155
Ventilation Suggestions

Wolf Ventilation Blower Options

INTERNAL BLOWER (CFM) 300 INT* 400 INT* 500 INT 600 INT 800 INT 1200 INT
COOKTOP HOOD

VW30B VW36B VW45B VI42B • •

VW30S VW36S VI42S • •

VW36G VW45G VI45G • •


CEILING-MOUNTED HOOD

VC36S VC36W VC48S VC48W •


DOWNDRAFT

DD30 DD36 DD45 •


PRO LOW-PROFILE WALL HOOD

PW302210 PW362210 •

PW422210 PW482210 •
PRO 24" WALL HOOD

PW302418 PW362418 PW422418 • • • • •

PW482418 PW542418 • • • • •

PW602418 PW662418 • • • • •
PRO 27" WALL HOOD

PW302718 PW362718 PW422718 • • • • •

PW482718 PW542718 • • • • •

PW602718 PW662718 • • • • •
PRO WALL CHIMNEY HOOD

PWC362418 PWC422418 • • • • •

PWC482418 PWC542418 • • • • •
PRO ISLAND HOOD

PI363418 PI423418 • • • • •

PI543418 • • • • •

PI663418 • • • • •
PRO HOOD LINER

PL341912 PL342212 PL401912 PL402212 • • • • •

PL461912 PL462212 • • • • •

PL521912 PL522212 • • • • •

PL581912 PL582212 • • • • •
OUTDOOR WALL HOOD

PW363318O PW483318O PW603318O •


*For make-up air restricted applications. Capture and performance may be reduced.

156 | Wolf Customer Care 800.222.7820


Ventilation Suggestions

Wolf Ventilation Blower Options

IN-LINE / REMOTE BLOWER (CFM) 600 IL 1100 IL 600 REM 900 REM 1500 REM
COOKTOP HOOD

VW30B VW36B VW45B VI42B • •

VW30S VW36S VI42S • •

VW36G VW45G VI45G • •


CEILING-MOUNTED HOOD

VC36S VC36W VC48S VC48W • •


DOWNDRAFT

DD30 DD36 DD45 • •


PRO LOW-PROFILE WALL HOOD

PW302210 PW362210 • • • • •

PW422210 PW482210 • • • • •
PRO 24" WALL HOOD

PW302418 • • • • •

PW362418 PW422418 PW482418 PW542418 • • • • •

PW602418 PW662418 • • • • •
PRO 27" WALL HOOD

PW302718 • • • • •

PW362718 PW422718 PW482718 PW542718 • • • • •

PW602718 PW662718 • • • • •
PRO WALL CHIMNEY HOOD

PWC362418 PWC422418 • • • • •

PWC482418 PWC542418 • • • • •
PRO ISLAND HOOD

PI363418 PI423418 • • • • •

PI543418 • • • • •

PI663418 • • • • •
PRO HOOD LINER

PL341912 PL342212 PL401912 PL402212 • • • • •

PL461912 PL462212 • • • • •

PL521912 PL522212 • • • • •

PL581912 PL582212 • • • • •
OUTDOOR WALL HOOD

PW363318O PW483318O PW603318O • •

wolfappliance.com | 157
Warranty

Wolf Appliance Residential Limited Warranty


FOR RESIDENTIAL USE

FULL TWO YEAR WARRANTY*


For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or
replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service
provided by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise speci-
fied by Wolf Appliance, Inc. Service will be provided during normal business hours.

LIMITED FIVE YEAR WARRANTY


For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defec-
tive in materials or workmanship: gas burners (excludes appearance), electric heating elements, blower motors (ventilation hoods),
electronic control boards, magnetron tubes and induction generators. If the owner uses Wolf Factory Certified Service, the service
provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified
service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf
Appliance will not reimburse the owner for parts purchased from non-certified service or other sources.

TERMS APPLICABLE TO EACH WARRANTY


The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one
of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any
parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE,
EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL
NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY
OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf Factory Certified Service nearest you, contact Wolf Appliance, Inc., P.O. Box
44848, Madison, WI 53744; check the Product Support section of our website, wolfappliance.com, email us at customerservice@
subzero.com or call 800-222-7820.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty
for cosmetic defects.
*Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.

158 | Wolf Customer Care 800.222.7820


Warranty

Wolf Appliance Outdoor Limited Warranty*


FOR RESIDENTIAL USE

FULL ONE YEAR WARRANTY**


For one year from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace,
under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided
by Wolf Appliance under the above warranty must be performed by Wolf Factory Certified Service, unless otherwise specified by
Wolf Appliance, Inc. Service will be provided during normal business hours.

LIMITED FIVE YEAR WARRANTY


For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective
in materials or workmanship: stainless steel briquette trays, gas valves, drip pans, electronic control boards and electric heating ele-
ments. If the owner uses Wolf Factory Certified Service, the service provider will repair or replace these parts with the owner paying
for all other costs, including labor. If the owner uses non-certified service, the owner must contact Wolf Appliance, Inc. (using the
information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from
non-certified service or other sources.

LIMITED LIFETIME WARRANTY


For the life of the product, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or work-
manship: all stainless steel components (excludes surface corrosion, scratches, discoloration, weather and atmospheric related
staining and minor surface rust and oxidation). If the owner uses Wolf Factory Certified Service, the service provider will repair or
replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certified service, the owner
must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not
reimburse the owner for parts purchased from non-certified service or other sources.

TERMS APPLICABLE TO EACH WARRANTY


The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one
of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any
parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE,
EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL
NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY
OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf Factory Certified Service nearest you, contact Wolf Appliance, Inc., P.O. Box
44848, Madison, WI 53744; check the Product Support section of our website, wolfappliance.com, email us at customerservice@
subzero.com or call 800-222-7820.
*Product must be approved for outdoor use, designated by model and serial number.
**Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty
for cosmetic defects.

wolfappliance.com | 159
WOLFAPPLIANCE.COM

You might also like