Professional Documents
Culture Documents
REVISED 10/2023
Design Guide
Contents
4 M Series Ovens
16 E Series Ovens
30 Convection Steam Ovens
38 Speed Ovens
44 Microwave Ovens
58 Warming Drawers
64 Induction/Electric Cooktops
72 Gas Cooktops
78 Module Cooktops
88 Coffee System
94 Cup Warming Drawer
98 Vacuum Seal Drawer
104 Dual Fuel Ranges
108 Gas Ranges
112 Induction Ranges
116 Sealed Burner Rangetops
120 Outdoor Grills/Modules
132 Cooktop Ventilation Hoods
142 Downdraft Ventilation
148 Pro Ventilation Hoods
158 Wolf Warranty
wolfappliance.com | 3
M Series Ovens
SO3050TM/S/TH
DO3050TM/S/TH
PROFESSIONAL
SO3050PM/S/PH
DO3050PM/S/PH
CONTEMPORARY
SO3050CM/S SO3050CM/B
DO3050CM/S DO3050CM/B
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
wolfappliance.com | 5
M Series Ovens
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
wolfappliance.com | 7
M Series Ovens
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
Planning Information
The M Series Oven can be installed in a standard or flush ELECTRICAL REQUIREMENTS
inset application. If a cooktop is installed above an oven, a
Installation must comply with all applicable electrical codes.
minimum of 1/4" (6) is required between the units. The loca-
Locate the electrical supply flush with the back wall and
tion of the electrical supply within the oven opening may
within the shaded area shown in the illustrations on the
require additional cabinet depth.
following pages. For ease of installation, the electrical
Finish the edges of the opening. They may be visible when supply for the oven can be placed in an adjacent cabinet
the door is open. within reach of the conduit.
For standard installations, the face trim will overlap stiles Performance may be compromised if the electrical supply
and rails. Refer to the chart below. is less than 240 volts.
For flush inset installations, a minimum 1/8" (3) reveal is The oven is supplied with a conduit consisting of two
required on all sides. To ensure consistent reveals, each insulated hot lead conductors and a bare ground con-
corner of the opening must be exactly 90°. ductor. The wiring diagram covering the control circuit is
provided with the oven.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN ELECTRICAL REQUIREMENTS—SINGLE OVEN
Single Oven 250 lb (115 kg) Electrical Supply grounded, 240/208 VAC, 60 Hz
Double Oven 400 lb (181 kg)
Service 30 amp dedicated circuit
TRIM OVERLAP
Conduit 4' (1.2 m)
Top 1" (25)
Bottom 0" (0) Total Amps 22
Sides 11/16" (18)
Max Connected Load 5.4 kW
Two M Series Single Ovens can be installed side by side in a Electrical Supply grounded, 240/208 VAC, 60 Hz
standard or flush inset application. A dual installation kit is Service 50 amp dedicated circuit
required. To maintain appropriate airflow, the ovens must
Conduit 5' (1.5 m)
be installed into one opening. Any cosmetic or structural
material placed between the ovens will impede airflow and Total Amps 45
is not recommended. Refer to the illustrations on pages Max Connected Load 10.8 kW
14–15.
The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
showroom section of our website, wolfappliance.com.
wolfappliance.com | 9
M Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E
(127)
4"
(102)
27 1/2"
(699) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT
NOTE: Location of electrical supply within opening may require additional cabinet depth.
TOP VIEW
30 1/8" (765)
FLUSH INSET WIDTH***
5"
11/8" (29) (127) E
4"
(102)
28 3/4"
(730)
FLUSH INSET
HEIGHT***
13/16" (21) E
1/8" (3)
E
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com | 11
M Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E
(127)
4"
(102)
49 7/8"
(1267) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT
E
17" (432)
TYPICAL
NOTE: Location of electrical supply within opening may require additional cabinet depth.
TOP VIEW
30 1/8" (765)
FLUSH INSET WIDTH***
5"
11/8" (29) (127) E
4"
(102)
51 1/8"
(1299)
FLUSH INSET
HEIGHT***
13/16" (21) E
1/8" (3)
E
17" (432)
TYPICAL
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
wolfappliance.com | 13
M Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E 5" E
(127) (127)
4" 4"
(102) (102)
27 1/2"
(699)
OPENING 58 1/2" (1486)
HEIGHT OPENING WIDTH
E E
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
TOP VIEW
60 1/8" (1527)
FLUSH INSET WIDTH***
5" E 5" E
11/8" (29) (127) (127)
4" 4"
(102) (102)
28 3/4"
(730)
FLUSH INSET
HEIGHT***
13/16" (21)
1/8" (3)
E E
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** 7/8" (22) for transitional, professional and contemporary stainless steel models and 1" (25) for contemporary black glass model.
***Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
wolfappliance.com | 15
E Series Ovens
SO24TE/S/TH
SO3050TE/S/TH
DO3050TE/S/TH
PROFESSIONAL
SO3050PE/S/PH
DO3050PE/S/PH
7/8" 22"
(22) (559)
23 1/2" 23 1/4"
(597) (591)
wolfappliance.com | 17
E Series Ovens
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
2" (51)
1 3/8" (36)
28 1/2" CONDUIT 27"
(724) CHANNEL (686)
28 1/2"
(724)
2" (51)
1 3/8" (36)
CONDUIT
CHANNEL
28 1/2"
(724)
50 7/8" 49 3/8"
(1292) (1254)
wolfappliance.com | 19
E Series Ovens
Planning Information
The E Series Oven can be installed in a standard or flush DUAL INSTALLATION
inset application. If a cooktop is installed above an oven, a
Two 30" E Series Single Ovens can be installed side by
minimum of 1/4" (6) is required between the units. The loca-
side in a standard or flush inset application. A dual instal-
tion of the electrical supply within the oven opening may
lation kit is required. To maintain appropriate airflow, the
require additional cabinet depth.
ovens must be installed into one opening. Any cosmetic or
Finish the edges of the opening. They may be visible when structural material placed between the ovens will impede
the door is open. airflow and is not recommended. Refer to the illustrations
on the following pages.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart below. The dual installation kit is available through an authorized
Wolf dealer. For local dealer information, visit the find a
For flush inset installations, a minimum 1/8" (3) reveal is
showroom section of our website, wolfappliance.com.
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Oven 150 lb (68 kg)
30" Single Oven 250 lb (113 kg)
30" Double Oven 400 lb (181 kg)
Electrical Requirements
24" OVEN 30" OVEN
Installation must comply with all applicable electrical codes. Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
Locate the electrical supply as shown in the illustrations
within the shaded area shown in the illustrations on the
on the following pages. A separate circuit servicing only
following pages. For ease of installation, the electrical
this appliance is required. A ground fault circuit interrupter
supply for the oven can be placed in an adjacent cabinet
(GFCI) is not recommended and may cause interruption
within reach of the conduit.
of operation. Refer to the illustration below for minimum
power cord plug clearance. Performance may be compromised if the electrical supply
is less than 240 volts.
Performance may be compromised if the electrical supply
is less than 240 volts. The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground con-
ELECTRICAL REQUIREMENTS—24" OVEN ductor. The wiring diagram covering the control circuit is
provided with the oven.
Electrical Supply grounded, 240/208 VAC, 60 Hz
Total Amps 22
wolfappliance.com | 21
E Series Ovens
23" (584)
OPENING
DEPTH
TOP VIEW
E E
23 1/4"
(591)
OPENING
HEIGHT
22 1/8" (562)
OPENING WIDTH
24" (610)
FLUSH
INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
E E 3/8" (10)
23 3/4" (603)
FLUSH INSET
HEIGHT** 13/16" (21)
1/8" (3)
23 3/4" (603)
FLUSH INSET WIDTH**
wolfappliance.com | 23
E Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E
(127)
4"
(102)
27 1/2"
(699) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT
NOTE: Location of electrical supply within opening may require additional cabinet depth.
24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
30 1/8" (765)
FLUSH INSET WIDTH**
5"
11/8" (29) (127) E
4"
(102)
28 3/4"
(730)
FLUSH INSET
HEIGHT**
13/16" (21) E
1/8" (3)
E
wolfappliance.com | 25
E Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E
(127)
4"
(102)
49 7/8"
(1267) 28 1/2" (724)
OPENING OPENING WIDTH
HEIGHT
E
17" (432)
TYPICAL
NOTE: Location of electrical supply within opening may require additional cabinet depth.
24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
30 1/8" (765)
FLUSH INSET WIDTH**
5"
11/8" (29) (127) E
4"
(102)
51 1/8"
(1299)
FLUSH INSET
HEIGHT**
13/16" (21) E
1/8" (3)
E
17" (432)
TYPICAL
wolfappliance.com | 27
E Series Ovens
23 1/4" (591)
OPENING
DEPTH
TOP VIEW
5" E 5" E
(127) (127)
4" 4"
(102) (102)
27 1/2"
(699)
OPENING 58 1/2" (1486)
HEIGHT OPENING WIDTH
E E
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
60 1/8" (1527)
FLUSH INSET WIDTH**
5" E 5" E
11/8" (29) (127) (127)
4" 4"
(102) (102)
28 3/4"
(730)
FLUSH INSET
HEIGHT**
13/16" (21)
1/8" (3)
E E
*1" (25) minimum depth. Shaded areas will be visible and should be finished to match cabinetry.
** Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth. A dual installation kit is required for this installation.
wolfappliance.com | 29
Convection Steam Ovens
PROFESSIONAL
CSO3050PM/S/P CSO3050PE/S/P
CSOP3050PM/S/P CSOP3050PE/S/P
CONTEMPORARY
CSO3050CM/B/T
CSOP3050CM/B/T
CONTEMPORARY HANDLELESS
7/8" A
(22)
17 7/8" 17 1/2"
(454) (446)
14 3/16"
OPEN OVEN DOOR (360)
WIDTH W A
PROFESSIONAL
7/8" 28 3/8"
(22) (721)
17 7/8" 17 1/2"
(454) (446)
14 3/16"
OPEN OVEN DOOR (360)
wolfappliance.com | 31
Convection Steam Ovens
7/8" 28 3/8"
(22) (721)
17 7/8" 17 1/2"
(454) (446)
14 3/16"
OPEN OVEN DOOR (360)
CONTEMPORARY HANDLELESS
7/8" A
(22)
17 7/8" 17 1/2"
(454) (446)
W 22 1/2" (572)
WIDTH BEHIND FRAME
14 3/16"
OPEN OVEN DOOR (360)
WIDTH W A
Planning Information
The Convection Steam Oven can be installed in a standard INSTALLATION REQUIREMENTS
or flush inset application. The back of the base support Minimum Base Support 150 lb (68 kg)
must be open for water and drain line accessibility and
TRIM OVERLAP 24" MODEL 30" MODEL
routing. Refer to the illustration below.
Top 3/16" (5) 3/16" (5)
Finish the edges of the opening. They may be visible when Bottom 0" (0) 0" (0)
the door is open. Sides 5/8" (16) 11/16" (18)
BACK OF
CABINET
4" (102)
18"
(457)
CL
Base support
wolfappliance.com | 33
Convection Steam Ovens
Electrical Requirements
Installation must comply with all applicable electrical codes. ELECTRICAL REQUIREMENTS
For ease of installation, the electrical supply for the oven Electrical Supply grounded, 240/208 VAC, 60 Hz
should be placed in an adjacent cabinet within reach of the Service 20 amp dedicated circuit
conduit.
Conduit 4' (1.2 m)
Performance may be compromised if the electrical supply
Total Amps 18
is less than 240 volts.
Max Connected Load 4.2 kW
The oven is supplied with a conduit consisting of two
hot lead conductors and a ground conductor. The wiring
diagram covering the control circuit is provided with the
oven.
Plumbing Requirements
PLUMBED MODELS ONLY PLUMBING REQUIREMENTS
IMPORTANT NOTE: The unit needs minerals in the water Water Connection 6.5' (2 m) braided tubing with
to operate. Do not connect to a filtered water supply. 3/8" female compression fitting
wolfappliance.com | 35
Convection Steam Ovens
23" (584)
OPENING
DEPTH
TOP VIEW
E
17 11/16"
(449)
OPENING
HEIGHT
E
E
W
OPENING WIDTH
NOTE: Location of electrical supply within opening may require additional cabinet depth.
OPENING WIDTH W
24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
5/16" (8) E
18 1/8"
(460)
FLUSH INSET A
HEIGHT**
1/8" (3)
E
E
W
FLUSH INSET WIDTH**
OPENING WIDTH W A
wolfappliance.com | 37
Speed Ovens
Speed Ovens
MODELS
TRANSITIONAL
PROFESSIONAL
SPO30PM/S/PH SPO30PE/S/PH
CONTEMPORARY
SPO30CM/B/TH
Speed Ovens
TRANSITIONAL
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
WIDTH W
wolfappliance.com | 39
Speed Ovens
Speed Ovens
PROFESSIONAL
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
CONTEMPORARY
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
Planning Information
The Speed Oven can be installed in a standard or flush ELECTRICAL REQUIREMENTS
inset application.
Installation must comply with all applicable electrical codes.
Finish the edges of the opening. They may be visible when
Locate the electrical supply as shown in the illustrations on
the door is open.
the following pages. The receptacle may also be located
For standard installations, the face trim will overlap stiles in an adjacent cabinet within reach of the power cord. A
and rails. Refer to the chart below. separate circuit, servicing only this appliance is required. A
ground fault circuit interrupter (GFCI) is not recommended
For flush inset installations, a minimum 1/8" (3) reveal is
and may cause interruption of operation. Refer to the illus-
required on all sides. To ensure consistent reveals, each
tration below for minimum power cord plug clearance.
corner of the opening must be exactly 90°.
If the Speed Oven is installed above or below a Wolf E ELECTRICAL REQUIREMENTS
Series Oven in a flush inset application, a 1/4" (6) reveal is
Electrical Supply grounded, 240/208 VAC, 60 Hz
required.
Service 15 amp dedicated circuit
INSTALLATION REQUIREMENTS Receptacle NEMA 6-20R grounding type
BASE SUPPORT MIN Power Cord 6' (1.8 m)
24" (610) Model 125 lb (57 kg)
30" (762) Model 125 lb (57 kg)
1" (25)
MINIMUM
CORD
GROUNDED CLEARANCE
NEMA RECEPTACLE
wolfappliance.com | 41
Speed Ovens
Speed Oven
STANDARD INSTALLATION
23" (584)
OPENING
DEPTH
TOP VIEW
E
17 11/16"
(449)
OPENING
HEIGHT
W
OPENING WIDTH
NOTE: 24" (610) and 30" (762) models require the same opening dimensions.
OPENING WIDTH W
Speed Oven
FLUSH INSET INSTALLATION
24" (610)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
E 5/16" (8)
18 1/8"
(460)
FLUSH INSET
A
HEIGHT**
1/8" (3)
W
FLUSH INSET WIDTH**
wolfappliance.com | 43
Microwave Ovens
Microwave Ovens
DROP-DOWN DOOR MICROWAVES
TRANSITIONAL
PROFESSIONAL
MDD30PM/S/PH MDD30PE/S/PH
CONTEMPORARY
MDD30CM/B/TH
DRAWER MICROWAVE
TRANSITIONAL
MD24TE/S MD30TE/S
PROFESSIONAL
MD30PE/S
CONVECTION MICROWAVE
STANDARD MICROWAVE
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
WIDTH W
PROFESSIONAL
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
CONTEMPORARY
7/8" 21 3/16"
(22) (538)
17 7/8" 17 1/2"
(454) (446)
OPEN
14 3/16"
(360)
OVEN DOOR
wolfappliance.com | 45
Microwave Ovens
15 1/8" 14 5/8"
(384) (372)
W 21 7/8" (556)
WIDTH BEHIND FRAME OPEN DRAWER
16 5/8"
(422)
WIDTH W
*11/4" (32) for contemporary E series trim only. *11/4" (32) for contemporary E series trim only.
30" Trim 297/8" (759) 297/8" (759) 30" Trim 297/8" (759) 297/8" (759)
wolfappliance.com | 47
Microwave Ovens
Planning Information
DROP-DOWN DOOR MICROWAVE DRAWER MICROWAVE
The Drop-Down Door Microwave Oven can be installed in The Drawer Microwave Oven can be installed in a standard
a standard or flush inset application. or flush inset application. The location of the electrical
supply within the oven opening may require additional
Finish the edges of the opening. They may be visible when
cabinet depth.
the door is open.
Finish the edges of the opening. They may be visible when
For standard installations, the face trim will overlap stiles
the drawer is open.
and rails. Refer to the chart below.
For standard installations, the face trim will overlap stiles
For flush inset installations, a minimum 1/8" (3) reveal is
and rails. Refer to the chart below.
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°. For flush inset installations, a minimum 1/8" (3) reveal is
required on the top and sides and 11/16" (18) on the bottom.
INSTALLATION REQUIREMENTS To ensure consistent reveals, each corner of the opening
BASE SUPPORT MIN
must be exactly 90°. A sales accessory is required to direct
Drop-Down Door Microwave 125 lb (57 kg) air away from the unit. Accessories are available through
an authorized Wolf dealer. For local dealer information,
TRIM OVERLAP 24" MODEL 30" MODEL
visit the find a showroom section of our website,
Top 3/16" (5) 3/16" (5)
wolfappliance.com.
Bottom 0" (0) 0" (0)
Sides 11/16" (18) 37/8" (98)
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
24" Drawer Microwave 125 lb (57 kg)
30" Drawer Microwave 125 lb (57 kg)
wolfappliance.com | 49
Microwave Ovens
21 9/16"
(548)
OPENING
DEPTH
TOP VIEW
E
17 11/16"
(449)
OPENING
HEIGHT
W
OPENING WIDTH
NOTE: 24" (610) and 30" (762) models require the same opening dimensions.
OPENING WIDTH W
23" (584)
FLUSH INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
E 5/16" (8)
18 1/8"
(460)
FLUSH INSET
A
HEIGHT**
1/8" (3)
W
FLUSH INSET WIDTH**
wolfappliance.com | 51
Microwave Ovens
22" (559)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
E
14 3/4" (375)
OPENING
HEIGHT
W
OPENING WIDTH
NOTE: All drawer microwave ovens require the same opening dimensions.
OPENING WIDTH W
23 3/8" (594)
FLUSH INSET
1 3/8" (35) DEPTH
FINISHED
CLEATS*
TOP VIEW
ANTI-TIP BLOCK
E 7/16" (11)
15 15/16" (405)
FLUSH INSET A
HEIGHT**
3/4" (19)
W
FLUSH INSET WIDTH**
wolfappliance.com | 53
Microwave Ovens
20 1/8" (511)
OPENING
DEPTH
TOP VIEW
18 7/8" (479)
OPENING
HEIGHT
W
OPENING WIDTH
OPENING WIDTH W
23 1/4" (591)
FLUSH INSET
1" (25) DEPTH
FINISHED
CLEATS*
TOP VIEW
E 3/8" (10)
20 1/8" (511)
FLUSH INSET A
HEIGHT**
7/8" (22)
W
FLUSH INSET WIDTH**
wolfappliance.com | 55
Microwave Ovens
20" (508)
OPENING
DEPTH
TOP VIEW
17" (432)
OPENING
HEIGHT
W
OPENING WIDTH
OPENING WIDTH W
23 1/4" (591)
FLUSH INSET
1" (25) DEPTH
FINISHED
CLEATS*
TOP VIEW
E 11/16" (17)
18 1/2" (470)
FLUSH INSET A
HEIGHT**
13/16" (21)
W
FLUSH INSET WIDTH**
wolfappliance.com | 57
Warming Drawers
Warming Drawers
WARMING DRAWER FRONTS
M SERIES
E SERIES
TRANSITIONAL PROFESSIONAL
INTEGRATED
CUSTOM PANEL
Warming Drawers
DRAWER FRONT OPTIONS DIMENSIONS
Wolf Warming Drawer fronts allow for many design A
options, but the warming drawer itself will be the same
for all applications. A panel mounting kit is required when 10 3/8" 9"
(264) (229)
installing a custom panel. The panel mounting kit is avail-
able through an authorized Wolf dealer. For local dealer
information, visit the find a showroom section of our W B 22 3/4" (578)
WIDTH
website, wolfappliance.com.
28 1/4" (718)
The 2" (51) thick drawer front, in 30" and 36" widths, is
designed to be installed below a Wolf Sealed Burner
Rangetop or Outdoor Grill, so the panel aligns properly
with the front of the rangetop or grill. Dimensions for the
warming drawer remain the same, even though the drawer
front may be wider to match the Sealed Burner Rangetop
or Outdoor Grill.
211/2"
OPEN DRAWER (546)
M/E SERIES A B
Stainless 7/8" (22) 31/4" (83)
Black 1" (25) 33/8" (86)
Stainless (2" thick) 21/8" (54) 41/2" (114)
wolfappliance.com | 59
Warming Drawers
Planning Information
The Warming Drawer must be installed with a Wolf drawer INSTALLATION REQUIREMENTS
front, available through an authorized Wolf dealer. For Min Base Support 200 lb (90 kg)
local dealer information, visit the find a showroom section
Trim Overlap (top, bottom, sides) 5/8" (16)
of our website, wolfappliance.com. Specific installation
instructions are included with the drawer front.
The Warming Drawer can be installed in a standard or flush
inset application.
For a standard installation, the drawer collar and front
panel sit proud of the cabinet face frame. A recessed
installation requires the cabinetry be recessed by 3/16" (5)
so the collar is flush with the cabinet face frame but the
drawer front will sit proud. A flush inset installation requires
the drawer collar and front panel be recessed to be flush
with surrounding cabinetry. Refer to illustrations on the
following pages for minimum cabinet dimensions for your
specific installation.
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adja-
cent cabinet within reach of the power cord.
IMPORTANT NOTE: When installed outdoors, a ground
fault circuit interrupter (GFCI) is required to reduce the risk
of electrical shock.
ELECTRICAL REQUIREMENTS
wolfappliance.com | 61
Warming Drawers
Warming Drawer
STANDARD INSTALLATION
23" (584)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
91/8" (232)
OPENING
HEIGHT E
28 5/8" (727)
OPENING WIDTH
NOTE: Location of electrical supply within opening may require additional cabinet depth.
Warming Drawer
FLUSH INSET INSTALLATION
A
DRAWER 24" (610)
FRONT FLUSH INSET
DEPTH DEPTH
FINISHED
CLEATS*
TOP VIEW
ANTI-TIP BLOCK
3/4" (19)
E
30 1/8" (765)
FLUSH INSET WIDTH**
Custom front panel depth is dependent on panel thickness. Add 1/4" (6)
to the panel thickness to determine the drawer front depth.
wolfappliance.com | 63
Induction/Electric Cooktops
Induction Cooktops
MODELS
TRANSITIONAL
CI30460T/S CI36560T/S
CONTEMPORARY
CI30460C/B CI36560C/B
TRANSITIONAL FRAMED
CI243TF/S CI304TF/S
CI365TF/S
Induction Cooktops
30" TRANSITIONAL 36" TRANSITIONAL
21" 21"
(533) (533)
7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)
21" 21"
(533) (533)
7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)
wolfappliance.com | 65
Electric Cooktops
Electric Cooktops
MODELS
TRANSITIONAL
CE304T/S CE365T/S
CONTEMPORARY
CE304C/B CE365C/B
Electric Cooktops
30" TRANSITIONAL 36" TRANSITIONAL
21" 21"
(533) (533)
7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)
21" 21"
(533) (533)
7/8" 7/8"
11/4" (32) (22) 11/4" (32) (22)
wolfappliance.com | 67
Induction/Electric Cooktops
Planning Information
A minimum 2" (51) is required from the bottom of the MULTIPLE COOKTOPS
cooktop to combustible materials.
When multiple cooktops or modules are installed side by
Clearance is required for the conduit located at the right side, the countertop cutout width is determined by adding
rear of the cooktop. Refer to the illustrations on the the width of each unit, then subtracting 1" (25). Refer to the
previous pages for dimensions for Induction and Electric illustration below.
Cooktops. Refer to the illustrations on the following pages
IMPORTANT NOTE: Contemporary Induction and Electric
for additional minimum clearances.
Cooktops are not designed to be installed in combination
with other cooktops.
FLUSH INSTALLATION
Contemporary Induction and Electric Cooktops can be
mounted flush with the top of the countertop or as a
frameless standard installation sitting on top of the coun- 2 1/2" (64)
tertop surface. If the cooktop is to be mounted flush with
the countertop, a recessed area surrounding the cooktop 19 1/2"
cutout must be provided. (495)
CUTOUT
DEPTH
IMPORTANT NOTE: Flush mount installations are intended
for granite, solid surface, or stone countertop surfaces
2 1/2" (64)
only.
CUTOUT WIDTH
(COMBINED WIDTH OF COOKTOPS MINUS 1")
Countertop cutout
Electrical Requirements
Installation must comply with all applicable electrical codes.
Refer to the illustrations on the following pages for loca-
tion of the electrical supply for Induction and Electric
Cooktops. A separate circuit servicing only this appliance
is required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
When multiple cooktops are installed side by side, each
unit must have its own separate recommended electrical
circuit.
ELECTRICAL REQUIREMENTS
INDUCTION
Electrical Supply grounded 3-wire, 240/208 VAC, 60 Hz
Conduit flexible 4' (1.2 m)
ELECTRIC
Electrical Supply grounded 3-wire, 240 VAC, 60 Hz
Electrical Supply (208 V) grounded 3-wire, 208 VAC, 60 Hz
Conduit flexible 4' (1.2 m)
SERVICE
24" Induction 30 amp dedicated circuit
30" Induction/Electric 40 amp dedicated circuit
36" Induction/Electric 50 amp dedicated circuit
wolfappliance.com | 69
Induction/Electric Cooktops
2 1/2" (64)
W 19 1/2"
WIDTH (495)
2 1/2" (64)
COUNTERTOP CUTOUT
2"
(51)
4 1/2" (114)
3 1/2" (89) E
10" (254)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.
CUTOUT WIDTH W
2 1/2" (64)
COUNTERTOP
PROFILE
5/16" (8) W
211/8" CUTOUT WIDTH 19 1/2"
(537) (495)
RECESS A
RECESS
COUNTERTOP CUTOUT
2"
(51)
4 1/2" (114)
3 1/2" (89) E
10" (254)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical supply location only applies to installations with built-in oven.
Outside corner radius 7/16 " (11).
CUTOUT WIDTH W A
wolfappliance.com | 71
Gas Cooktops
Gas Cooktops
MODELS
TRANSITIONAL FRAMED
CG243TF/S
TRANSITIONAL
CG304T/S CG365T/S
PROFESSIONAL
CG304P/S CG365P/S
CONTEMPORARY
CG365C/S
Gas Cooktops
24" TRANSITIONAL 30" TRANSITIONAL 36" TRANSITIONAL
21" 21"
(533) (533)
7/8" 7/8"
(22) (22)
36" CONTEMPORARY
20 15/16"
(532)
35 15/16" (913)
6 3/4" (171)
7/8"
(22)
wolfappliance.com | 73
Gas Cooktops
Planning Information
A minimum 2" (51) is required from the bottom of the GAS SUPPLY
cooktop to combustible materials. If the cooktop is
Installation must comply with all applicable gas codes.
installed above an oven, a minimum of 1/4" (6) is required
between the units. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
The Contemporary Gas Cooktop can be mounted flush
with the top of the countertop, or as a standard installation Wolf natural gas cooktops will function up to 10,250'
sitting on top of the countertop surface. If the cooktop is (3124 m) in altitude without adjustment and LP gas cook-
to be mounted flush with the countertop, a recessed area tops will function up to 8,600' (2621 m). If the installation
surrounding the cooktop cutout must be provided. The exceeds these elevations, contact an authorized Wolf
countertop must be able to withstand temperatures up to dealer for a high altitude conversion kit.
300°F (149°C).
GAS REQUIREMENTS
Control knobs for the Contemporary Gas Cooktop are
designed to be mounted on the front face of cabinetry Gas Supply 3/4" ID line
below the unit. Mounting holes must be drilled through the Gas Inlet 1/2" NPT male
cabinet face. Refer to the illustrations on pages 76–77 for
NATURAL GAS WC
the hole location.
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
ELECTRICAL REQUIREMENTS Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
ELECTRICAL REQUIREMENTS
2 1/2" (64)
W 19 1/2"
WIDTH (495)
2 1/2" (64)
COUNTERTOP CUTOUT
9"
(229)
4" (102)
3 1/2" (89) E G
10" (254)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical and gas supply location only applies to installations with built-in oven.
CUTOUT WIDTH W
wolfappliance.com | 75
Gas Cooktops
2 1/2" (64)
COUNTERTOP CUTOUT
9"
(229)
3 7(102)
4" /8" (98) MIN – 51/8" (130) MAX
2" (51) MIN – CL
5" (127) MAX 5"
(127) 11/4" (32)
DIAMETER
10"
(254)
CL E G
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines.
2 1/2" (64)
COUNTERTOP
PROFILE
5/64" (2) 35" (889)
21" CUTOUT WIDTH 20"
(533) MIN (508)
RECESS 36" (914) MIN
RECESS
COUNTERTOP CUTOUT
9"
(229)
3 7(102)
4" /8" (98) MIN – 51/8" (130) MAX
2" (51) MIN – CL
5" (127) MAX 5"
(127) 11/4" (32)
DIAMETER
10"
(254)
CL E G
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Maximum facade thickness 1" (25). 1" (25) thickness extends 17" (432) left and right and 2" (51) above and below centerlines.
Outside corner radius 3 /8 " (10).
wolfappliance.com | 77
Module Cooktops
Module Cooktops
MODELS
Module Cooktops
INDUCTION STEAMER FRYER GRILL
wolfappliance.com | 79
Module Cooktops
Planning Information
IMPORTANT NOTE: Wolf does not recommend the use MULTIPLE COOKTOPS
of downdraft ventilation with the Steamer, Fryer, or Grill
When multiple cooktops or modules are installed side by
Modules.
side, refer to the chart and illustration below for typi-
A minimum 2" (51) is required from the bottom of the cal configurations. The cutout dimensions provided will
module to combustible materials. For the Teppanyaki accommodate the use of an optional filler strip if desired.
Module, a minimum 7/8" (22) is required from the bottom of
For specific multiple cooktop and module configuration
the unit to any material.
options or the installation of more than six modules, con-
Refer to the illustrations on the following pages for instal- tact Wolf Customer Care at 800-222-7820.
lation of Module Cooktops.
COUNTERTOP CUTOUT W
W
CUTOUT WIDTH
2 1/2"
(64) min 191/2"
(495)
CUTOUT
2 1/2" DEPTH
(64) min
FRONT OF COUNTERTOP
Countertop cutout
Planning Information
ELECTRICAL DRAIN OUTLET
Installation must comply with all applicable electrical codes. Steamer and Fryer Modules require a method for draining
hot water and oil. For the Steamer Module, options include
Locate the electrical supply as shown in the illustrations on
connecting a drain hose from the 5/8" (16) outlet tied into
the following pages. A separate circuit servicing only this
an existing drain, a separate drain with freefall, or placing
appliance is required.
a heat-resistant receptacle under the drain outlet. For the
When multiple cooktops or modules are installed side by Fryer Module, the drain outlet must be accessible to drain
side, each must have its own separate electrical supply. oil into a heat-resistant receptacle.
ELECTRICAL REQUIREMENTS
ELECTRIC MODULES
Electrical Supply grounded 3-wire, 240/208 VAC, 50/60 Hz
Steamer, Fryer, Grill, Teppanyaki 15 amp dedicated circuit
Induction 20 amp dedicated circuit
Conduit flexible 4' (1.2 m)
GAS MODULES
Electrical Supply grounded, 120 VAC, 50/60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6' (1.8 m)
wolfappliance.com | 81
Module Cooktops
Planning Information
GAS SUPPLY GAS REQUIREMENTS
Installation must comply with all applicable gas codes. Gas Supply 3/4" ID line
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" Gas Inlet 1/2" NPT male
(19) ID flexible metal appliance connector is recommended. NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
When multiple gas cooktops or modules are installed side
Min Line Pressure 7" (17.5 mb)
by side, they can receive their gas supply from a common
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module. LP GAS WC
Supply Pressure 10" (25 mb)
Wolf natural gas cooktops will function up to 10,250' Min Line Pressure 11" (27.4 mb)
(3124 m) in altitude without adjustment and LP gas cook- Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
tops will function up to 8,600' (2621 m). If the installation
exceeds these elevations, contact an authorized Wolf
dealer for a high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Induction Module
STANDARD INSTALLATION
2 1/2" (64)
14" 19 1/2"
(356) (495)
2 1/2" (64)
COUNTERTOP CUTOUT
2"
(51)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
wolfappliance.com | 83
Module Cooktops
Steamer Module
STANDARD INSTALLATION
14" 19 1/2"
(356) (495)
COUNTERTOP CUTOUT
7"
(178)
7 7/8" 6"
(200) 12 3/8" (152)
(314)
DRAIN
OUTLET
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
WARNING
The Steamer Module must be installed at least 15" (381)
from a Fryer Module.
Fryer Module
STANDARD INSTALLATION
14" 19 1/2"
(356) (495)
COUNTERTOP CUTOUT
7"
(178)
7 7/8" 6"
(200) 12 3/8" (152)
(314)
DRAIN
OUTLET
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
WARNING
The Fryer Module must be installed at least 15" (381)
from any open-flame cooking device or a Steamer
Module.
wolfappliance.com | 85
Module Cooktops
14" 19 1/2"
(356) (495)
COUNTERTOP CUTOUT
7"
(178)
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
2 1/2" (64)
14" 19 1/2"
(356) (495)
2 1/2" (64)
COUNTERTOP CUTOUT
7"
(178)
E G
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
wolfappliance.com | 87
Coffee System
Coffee System
MODELS
24" TRANSITIONAL
EC2450TE/S
30" TRANSITIONAL
EC3050TE/S EC3050TM/S
30" PROFESSIONAL
EC3050PE/S EC3050PM/S
30" CONTEMPORARY
EC3050CM/S EC3050CM/B
Coffee System
DIMENSIONS
7/8"
(22)
17 7/8"
(454)
W 19" (483)
WIDTH BEHIND FRAME UNIT 181/4"
FULL EXTENSION (464)
WIDTH W
wolfappliance.com | 89
Coffee System
Planning Information
The Coffee System can be installed in a standard or flush COMBINATION INSTALLATIONS
inset application. The sides of the cabinet opening must
If a Coffee System is installed above a Cup Warming
be adequate to support installation of the mounting slides.
Drawer, specify one opening for both units. To achieve
Refer to the illustration below.
the minimum reveal between the units, place the Coffee
Finish the edges of the opening. System support rails on top of the Cup Warming Drawer,
then secure the rails to the sides of the cabinet. Any
For standard installations, the face trim overlaps stiles and
material between the units will increase the horizontal
rails. Refer to the chart below.
reveal between the two products.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. Each corner of the opening must be
exactly 90° to maintain consistent reveals.
INSTALLATION REQUIREMENTS
3/4" (19)
TYPICAL
14"
(356) 3" (76)
Slide support
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
wolfappliance.com | 91
Coffee System
Coffee System
STANDARD INSTALLATION
21 9/16"
(548)
SLIDE OPENING
SUPPORT DEPTH
TOP VIEW
17 11/16" (449)
SLIDE OPENING E
SUPPORT HEIGHT
W
OPENING WIDTH
NOTE: 24" (610) model and 30" (762) model require the same opening dimensions.
OPENING WIDTH W
Coffee System
FLUSH INSET INSTALLATION
23" (584)
SLIDE FLUSH
SUPPORT INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
5/16" (8)
18 1/8" (460)
SLIDE FLUSH INSET A E
SUPPORT HEIGHT**
1/8" (3)
W
FLUSH INSET WIDTH**
wolfappliance.com | 93
Cup Warming Drawer
CW24/S
STAINLESS
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Cup Warming Drawer 75 lb (34 kg)
COMBINATION INSTALLATION
To install a Cup Warming Drawer below a Coffee System,
one opening for both units must be specified. To achieve
the minimum reveal between the units, place the Coffee
System support rails on top of the Cup Warming Drawer,
then secure the rails to the sides of the cabinet. Any mate-
rial between the units will increase the horizontal reveal.
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
wolfappliance.com | 95
Cup Warming Drawer
22 1/2"
(572)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
5 1/2" (140) E
OPENING HEIGHT
22 1/8" (562)
OPENING WIDTH
23 1/2" (597)
FLUSH
INSET
7/8" (22) DEPTH
FINISHED
CLEATS*
TOP VIEW
1/8" (3)
ANTI-TIP BLOCK
23 3/4" (603)
FLUSH INSET WIDTH**
wolfappliance.com | 97
Vacuum Seal Drawer
Dimensions
VACUUM SEAL DRAWER DRAWER FRONT
5 1/2" 5 1/2"
(140) (140)
DRAWER FRONT W
wolfappliance.com | 99
Vacuum Seal Drawer
Planning Information
The Vacuum Seal Drawer can be installed in a standard or FILLER
flush inset application. Finish the edges of the opening.
A filler is required if installed below a countertop. The lid
They may be visible when the drawer is open.
is designed to remain open at 60°. Refer to the illustration
For standard installations, face trim will overlap stiles and below.
rails. Refer to the chart below.
For flush inset installations, a minimum 1/8" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
2" (51)
INSTALLATION REQUIREMENTS
TRIM OVERLAP
Top 0" (0)
Bottom 0" (0)
Sides 11/16" (18)
Filler
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
wolfappliance.com | 101
Vacuum Seal Drawer
22 1/2"
(572)
OPENING
DEPTH
TOP VIEW
ANTI-TIP BLOCK
5 9/16" (141) E
OPENING HEIGHT
22 1/8" (562)
OPENING WIDTH
23 1/2" (597)
FLUSH
INSET
7/8" (22)** DEPTH
FINISHED
CLEATS*
TOP VIEW
1/16" (2)
ANTI-TIP BLOCK
W
FLUSH INSET WIDTH***
wolfappliance.com | 103
Dual Fuel Ranges
DF36450C/S/P DF48450CG/S/P
DF36450G/S/P DF48450DG/S/P
DF48450F/S/P
29
291/12/"2"(749)
(749)
26
267/78/"8(683)
" (683)
60" RANGE 24"
24"(610)
(610)
36
361/12/"2" 35
351/12/"2"
(927)
(927) (902)*
(902)*
59
597/78/"8"(1521)
(1521) 26"
26"(660)
(660)
47
471/14/"4(1200)
" (1200)
*35
*351/12/"2(902)
" (902)MIN TO38"
MINTO 38"(965)
(965)MAX
MAX
wolfappliance.com | 105
Dual Fuel Ranges
Planning Information
IMPORTANT NOTE: When installing against a combustible GAS SUPPLY
surface, a minimum 10" (254) riser is required for a 36" dual
Installation must comply with all applicable gas codes.
fuel range with charbroiler or griddle and all 48" and 60"
models. Follow all minimum clearances to combustible If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
surfaces shown in the illustration on the following page. (19) ID flexible metal appliance connector is recommended.
A Wolf Pro Ventilation Hood is recommended with the Wolf natural gas ranges will function up to 10,250' (3124 m)
Dual Fuel Range. Refer to page 148 for Pro Ventilation. in altitude without adjustment and LP gas ranges will func-
tion up to 8,600' (2621 m). If the installation exceeds these
elevations, contact an authorized Wolf dealer for a high
ELECTRICAL REQUIREMENTS
altitude conversion kit.
Installation must comply with all applicable electrical codes.
GAS REQUIREMENTS
Locate the electrical supply flush with the wall or floor
and within the shaded area shown in the illustration on Gas Supply 3/4" ID line
the following page. A separate circuit servicing only this Gas Inlet 1/2" NPT female
appliance is required.
NATURAL GAS WC
If a power supply cord is used, the cord must be designated Supply Pressure 5" (12.5 mb)
for use with ranges and rated for 240 V, 30 or 50 amps Min Line Pressure 7" (17.5 mb)
(refer to the chart below), and must include 3 or 4 conduc- Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
tors. A 4-conductor cord is required for installations where LP GAS WC
grounding through the neutral is prohibited. Supply Pressure 10" (25 mb)
Performance may be compromised if the electrical supply Min Line Pressure 11" (27.4 mb)
is less than 240 volts. Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Total Amps 21
6"
(152)
W
OPENING WIDTH
ELECTRICAL
AND GAS IN A 8 1/2"
‘A’ LOCATION (216)
ONLY 4 7/8" E G
(124)
2"
(51) SIDE VIEW FRONT VIEW
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH W A
wolfappliance.com | 107
Gas Ranges
Gas Ranges
CONFIGURATIONS
30" RANGE 48" RANGE 60" RANGE
GR366 GR486G
GR364C GR484CG
GR364G GR484DG
9 1/4" 9 1/4"
Gas Ranges (235)
46" (1168)
(235)
46" (1168)
37" 36" 25 3/8" (645) 37" 37" 36" 25 3/8" (645) 37" 37" 36"
(940)* (914) (940)* (940)* (914) (940)*(940)* (914)
*37" (940) MIN TO 38" (965) MAX. *37" (940) MIN TO 38" (965) MAX.
28 3/8" (721)
27" (686)
56" (1422)
9 1/4"
(235)
46" (1168)
2 1/2"
(64)
wolfappliance.com | 109
Gas Ranges
Planning Information
When installing against a combustible surface, a minimum GAS SUPPLY
20" (508) riser is required. Follow all minimum clearances
Installation must comply with all applicable gas codes.
to combustible surfaces shown in the illustration on the
following page. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
A Wolf Pro Ventilation Hood is recommended with the Gas
Range. Refer to page 148 for Pro Ventilation. Wolf natural gas ranges will function up to 8,600' (2621 m)
in altitude without adjustment. If the installation exceeds
this elevation, contact an authorized Wolf dealer for a high
ELECTRICAL REQUIREMENTS
altitude conversion kit. LP models do not require conver-
Installation must comply with all applicable electrical codes. sion.
Locate the electrical supply flush with the wall or floor and
GAS REQUIREMENTS
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance Gas Supply 3/4" ID line
is required. Gas Inlet 1/2" NPT female
NATURAL GAS WC
ELECTRICAL REQUIREMENTS
Supply Pressure 5" (12.5 mb)
Electrical Supply grounded, 110/120 VAC, 60 Hz Min Line Pressure 7" (17.5 mb)
Service 15 amp dedicated circuit Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Receptacle 3-prong grounding-type
Supply Pressure 10" (25 mb)
Power Cord 6' (1.8 m) Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
Gas Range
INSTALLATION
6"
(152)
W
OPENING WIDTH
5 3/4" E
(146)
LOCATION OF GAS AND
ELECTRICAL EXTENDS
ON FLOOR 7 3/4" (197) 2" (51)
G
3" 12" 5"
(76) SIDE VIEW FRONT VIEW (305) GAS (127)
*Without ventilation hood, 42" (1067) minimum clearance countertop to combustible materials, charbroiler and GR488 require non-combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH W
wolfappliance.com | 111
Induction Ranges
Induction Ranges
CONFIGURATIONS
TRANSITIONAL
IR30450/S/T IR36550/S/T
PROFESSIONAL
IR30450/S/P IR36550/S/P
Induction Ranges
28 1/4" (718) 28 1/4" (718)
30" TRANSITIONAL 36" TRANSITIONAL
27 1/2" (699) 27 1/2" (699)
24 1/4" (616) 24 1/4" (616)
35 1/2" 35 1/2"
(902)* (902)*
SIDE VIEW—TRANSITIONAL
35 1/2" 35 1/2"
(902)* (902)*
SIDE VIEW—PROFESSIONAL
wolfappliance.com | 113
Induction Ranges
Planning Information
Follow all minimum clearances to combustible surfaces ELECTRICAL REQUIREMENTS
shown in the illustration on the following page.
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit servicing only this appliance
is required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 50 amps,
and must include 3 or 4 conductors. A 4-conductor cord
is required for installations where grounding through the
neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
Induction Range
INSTALLATION
6"
(152)
W
OPENING WIDTH
ELECTRICAL IN A 8 1/2"
‘A’ LOCATION (216)
ONLY 4 7/8" E
(124)
2"
(51) SIDE VIEW FRONT VIEW
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces.
Combustible materials cannot be located within this area.
For island installation, 12" (305) minimum clearance back of range to combustible rear wall above countertop.
OPENING WIDTH W A
wolfappliance.com | 115
Sealed Burner Rangetops
SRT364C SRT486G
SRT364G SRT484CG
SRT362W SRT484DG
SRT484W
28 1/2" (724)
27 1/2" (699)
9 1/4"
Sealed Burner Rangetops (235)
17 1/2" (445)
28 1/2" (724)
27 1/2" (699)
9 1/4"
36" RANGETOP (WOK MODEL SHOWN) (235) 17 1/2" (445)
11/2" (38)
12 1/2" (318)
9 1/4"
(235)
17 1/2" (445)
wolfappliance.com | 117
Sealed Burner Rangetops
Planning Information
The platform to support the Sealed Burner Rangetop must ELECTRICAL REQUIREMENTS
include a cutout for electrical and gas supply connections.
Installation must comply with all applicable electrical codes.
Refer to the chart below for minimum base support.
Locate the electrical supply within the shaded area shown
When installing against a combustible surface, a mini-
in the illustration on the following page. A separate circuit
mum 5" (127) riser is required for model SRT366, and a
servicing only this appliance is required.
minimum 10" (254) riser is required for 36" and 48" Sealed
Burner Rangetops with a charbroiler or griddle. Follow all
ELECTRICAL REQUIREMENTS
minimum clearances to combustible surfaces shown in
the illustration on the following page. Models SRT362W Electrical Supply grounded, 110/120 VAC, 60 Hz
and SRT484W cannot be installed against a combustible Service 15 amp dedicated circuit
surface.
Receptacle 3-prong grounding-type
A Wolf Pro Ventilation Hood is recommended with
Power Cord 6' (1.8 m)
the sealed burner rangetop. Refer to page 148 for Pro
Ventilation.
A downdraft can be used with Models SRT304 and SRT366. GAS SUPPLY
An accessory trim kit is necessary for this installation. Con- Installation must comply with all applicable gas codes.
tact an authorized Wolf dealer for details.
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4"
(19) ID flexible metal appliance connector is recommended.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN Wolf natural gas rangetops will function up to 10,250'
30" Rangetop 200 lb (91 kg) (3124 m) in altitude without adjustment and LP gas ran-
36" Rangetop 250 lb (113 kg) getops up to 8,600' (2621 m). If the installation exceeds
48" Rangetop 300 lb (136 kg) these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
PLATFORM MIN
Thickness 3/4" (19)
GAS REQUIREMENTS
NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
Min Line Pressure 7" (17.5 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
LP GAS WC
Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
6"
(152)
7 1/2" (191)
OPENING W
HEIGHT OPENING WIDTH
E G
16" (406)
ELECTRICAL
AND GAS
*Without ventilation hood, 36" (914) minimum clearance countertop to combustible materials, 44" (1118) for charbroiler.
NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,
combustible materials cannot be located within this area.
Electrical and gas supply located through bottom of platform.
For island installation, 12" (305) minimum clearance back of rangetop to combustible rear wall above countertop.
OPENING WIDTH W
wolfappliance.com | 119
Outdoor Grills/Modules
OG54
OUTDOOR MODULES
BM13 SB13
BURNER MODULE SIDE BURNER
27"
(686)
W 27 3/4" (705)
WIDTH
GRILL CART
12"
(305)
36 1/2"
24" (610) (927)
TO GRILL
PLATFORM
3" (76)
W 27 3/4" (705)
WIDTH
wolfappliance.com | 121
Outdoor Grills/Modules
Planning Information
For portable applications, Wolf grill carts are designed ELECTRICAL REQUIREMENTS
specifically to fit Grill Models OG30, OG36, and OG42
Installation must comply with all applicable electrical codes.
and the Side Burner. Model OG54 is designed for built-in
applications only. The electrical outlet must be located within reach of the
power cord. A separate circuit servicing only this appli-
For built-in applications, Wolf Outdoor Grills and the
ance is required. A ground fault circuit interrupter (GFCI) is
Burner Module are designed for easy placement into
required to reduce the risk of electrical shock.
a built-in enclosure. For outdoor grills, installation in a
combustible enclosure requires an insulating liner. For
ELECTRICAL REQUIREMENTS
the Burner Module, an insulating liner is not required.
The enclosure should be built according to specifica- Electrical Supply grounded, 120 VAC, 60 Hz
tions for your specific installation on the following pages. Service 15 amp dedicated circuit
If the Burner Module is installed next to an Outdoor Grill,
Receptacle 3-prong grounding-type, GFCI
a minimum of 12" (305) is required between the units on
the rotisserie motor side and 2" (51) on the opposite side. A Power Cord 6' (1.8 m)
rotisserie side conversion kit is available from an authorized
Wolf dealer.
Model BM13 does not include a tank retention system and
cannot be connected to a portable LP tank.
Optional stainless steel accessory doors and drawers are
available for built-in applications. Refer to pages 126–130.
Grill carts, insulating liners, and stainless steel doors and
drawers are available through an authorized Wolf dealer.
For local dealer information, visit the find a showroom sec-
tion of our website, wolfappliance.com.
Installation must comply with all applicable gas codes. Gas Supply 3/4" ID line
If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" Gas Inlet 1/2" NPT female
(19) ID flexible metal appliance connector is recommended. NATURAL GAS WC
Supply Pressure 5" (12.5 mb)
If the Outdoor Grill is being connected to a whole house
Min Line Pressure 7" (17.5 mb)
LP supply, the LP gas pressure regulator is not provided.
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
It can be purchased from an authorized Wolf dealer. For
local dealer information, visit the find a showroom section LP GAS WC
of our website, wolfappliance.com. Supply Pressure 10" (25 mb)
Min Line Pressure 11" (27.4 mb)
Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)
wolfappliance.com | 123
Outdoor Grills/Modules
Outdoor Grill
NON-COMBUSTIBLE INSTALLATION COMBUSTIBLE INSTALLATION
12" (305)
2 1/2" (64)
10 3/4"
13" G (273) C
24 1/4" (616) (330) TRIM 26" (660) L TRIM
OPENING OVERLAP OPENING G CL OVERLAP
DEPTH DEPTH 2 3/4" (70)
31/2" KNOCKOUT
5"
(127)
(89)
6" 12"
(152) (305)
W W
OPENING WIDTH OPENING WIDTH
13/16" 13/16"
(21) (21)
OPENING OPENING
COUNTERTOP COUNTERTOP
OVERHANG OVERHANG
NOTE: Shaded area above countertop indicates minimum clearance to NOTE: Shaded area above countertop indicates minimum clearance to
combustible surfaces, combustible materials cannot be located within this area. combustible surfaces, combustible materials cannot be located within this area.
Burner Module
INSTALLATION
12" (305)
G 3" (76)
6"
(152)
TOP VIEW
12" (305)
OPENING
10" (254)
OPENING 8"
G (203)
HEIGHT
7"
(178)
9/16"
(14)
MODULE
OPENING
COUNTERTOP
OVERHANG
FRONT VIEW
wolfappliance.com | 125
Outdoor Accessories
Outdoor Accessories
ACCESS DOORS ACCESSORY DRAWERS AND DOORS
SINGLE DRAWER
TRASH/RECYCLING
DRAWER
Access Doors
DIMENSIONS INSTALLATION
B 3 1/2" (89)
FINISHED
RETURN
2 3/4" (70)
W
TOP VIEW
A GRILL OPENING
1" (25) min
19" (483)
20 3/4" 18 3/4" OPENING
(527) (476) HEIGHT
W
OPENING WIDTH
DOOR WIDTH A B
FRONT VIEW
18" Single 18" (457) 161/4" (413)
wolfappliance.com | 127
Outdoor Accessories
24" 18"
(610) (457)
11 3/8" 9 1/2"
(289) (241)
20 3/4" 19"
(527) (483)
14 1/2" (368)
DRAWER/DOOR
28 1/2" (724)
19"
(483)
18"
2 3/4" (70) (457)
18" (457)
2 3/4" (70)
10" 8"
(254) (203) 30" (762)
20 3/4" 19"
(527) (483)
19 3/4"
(502)
D
2 3/4" (70)
2 3/4" (70)
24" (610)
18" (457)
26" 24"
34" 32" (660) (610)
(864) (813)
19 3/4"
(502)
2 3/4" (70)
36" (914)
20 3/4" 18 3/4"
(527) (476)
wolfappliance.com | 129
Outdoor Accessories
OPENING W H D
wolfappliance.com | 131
Cooktop Ventilation Hoods
Cooktop Hoods
MODELS
BLACK
VI42B ISLAND
STAINLESS
GLASS
Cooktop Hoods
WALL HOODS—BLACK
11 3/4" 10 1/4"
(298) (260)
29 1/8" (740)
TO 211/4"
39 1/4" (997)* (540)
21/4" (57)
W 19 1/4"
WIDTH (489)
WIDTH W
ISLAND HOOD—BLACK
13 3/4" 111/4"
(349) (286)
23 5/8" (600)
TO 23 1/4"
32" (813)* (591)
21/4" (57)
42" 26 1/2"
(1067) (673)
wolfappliance.com | 133
Cooktop Ventilation Hoods
Cooktop Hoods
WALL HOODS—STAINLESS
11 3/4" 10 1/4"
(298) (260)
6"
(152)
W 22"
WIDTH (559)
WIDTH W
ISLAND HOOD—STAINLESS
13 3/4" 111/4"
(349) (286)
6"
(152)
42" 26 1/2"
(1067) (673)
Cooktop Hoods
WALL HOODS—GLASS
11 3/4" 10 1/4"
(298) (260)
29 1/8" (740)
TO 211/4"
39 1/4" (997)* (540)
21/4" (57)
W 19 1/4"
WIDTH (489)
WIDTH W
ISLAND HOOD—GLASS
13 3/4" 111/4"
(349) (286)
23 5/8" (600)
TO 23 1/4"
32" (813)* (591)
21/4" (57)
45" 26 1/2"
(1143) (673)
wolfappliance.com | 135
Cooktop Ventilation Hoods
Planning Information
Wolf Cooktop Ventilation Hoods are recommended for ELECTRICAL REQUIREMENTS
use with Wolf Induction, Electric and Gas Cooktops, and
Installation must comply with all applicable electrical codes.
Modules. For Wolf Ranges and Rangetops, a Pro Ventilation
Hood is recommended. For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. For island
These hoods have a telescopic chimney flue. A flue exten-
hoods, locate the electrical supply on the ceiling inside the
sion is available through an authorized Wolf dealer.
top of the hood. A separate circuit servicing only this appli-
Installation of the cooktop hood should be 24" (610) to ance is required.
36" (914) from the bottom of the hood to the countertop.
ELECTRICAL REQUIREMENTS
Wall and island hoods require an internal, in-line, or remote
blower assembly, available through an authorized Wolf Electrical Supply grounded, 110/120 VAC, 60 Hz
dealer. For local dealer information, visit the find a show- Service 15 amp dedicated circuit
room section of our website, wolfappliance.com. Refer to
Ventilation Suggestions on pages 154–157. Cooktop Hoods
have a vertical discharge with 6" (152) round duct.
Consult a qualified HVAC professional for specific installa-
tion and ducting applications. LOCATE
ELECTRICAL
WITHIN
SHADED AREA E
20"
(508)
Ceiling-Mounted Hood
The Ceiling-Mounted Hood is our most contemporary CEILING-MOUNTED HOOD
ventilation offering, nearly disappearing into its surround- STAINLESS STEEL
ings. It comes in two widths and is available in stainless
steel or white glass. The hood ships with a remote control
and can be operated using the remote control or the con-
trol panel. The control panel is recessed into the right side
VC36S VC48S
of the hood. The dishwasher-safe filters can be removed
easily for cleaning.
WHITE GLASS
VC36W VC48W
wolfappliance.com | 137
Cooktop Ventilation Hoods
Ceiling-Mounted Hood
STAINLESS STEEL
A
13 1/4" 13 1/4"
(337) (337)
7 1/4" (184)
7 1/4" TO
(184)
12 3/4" (324)
5" (127)
DIMENSIONS W A
WHITE GLASS
A
13 1/4" 13 1/4"
(337) (337)
7 1/4" (184)
7 1/4" TO
(184)
12 3/4" (324)
5" (127)
DIMENSIONS W A
Planning Information
Installation of the Ceiling-Mounted Hood should be 36" RECIRCULATING APPLICATION
(914) to 84" (2134) from the bottom of the hood to the
The Ceiling-Mounted Hood with an internal blower only,
countertop.
can be installed in a recirculating application. The air dis-
The hood can be operated using the remote control or the charge must be a minimum of 40" (1016) from every side of
control panel located on the right side of the hood. the hood. Refer to the illustration below. The ductwork and
vent cover are not provided. A recirculation kit, available
The hood is shipped without a blower assembly. Inter-
through an authorized Wolf dealer, is required.
nal, in-line, and remote blowers are available through an
authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com. Refer to Ventilation Suggestions on
pages 154–157.
Ceiling-Mounted Hoods include a 6" (152) round discharge
for internal blowers and a 10" (254) round discharge for in-
line and remote blowers. For an internal blower, the blower
box can be rotated to discharge right, left, front, or rear.
For an in-line or remote blower, the discharge is vertical
only. 40" (1016)
MIN
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
Recirculating application
wolfappliance.com | 139
Cooktop Ventilation Hoods
Planning Information
ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. Allow a minimum 12" (305)
Romex® wire for connection. A separate circuit servicing
only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical location
Opening Dimensions
CEILING-MOUNTED HOOD
Refer to the chart and illustrations below for opening
dimensions and typical framing. Framing must be able to
support a minimum of 100 lb (45 kg).
HOOD W
20"
(508) W
Opening dimensions
wolfappliance.com | 141
Downdraft Ventilation
Downdraft Ventilation
MODELS
DD30 DD36
DD45
Downdraft Ventilation
DIMENSIONS
W 2"
DOWNDRAFT WIDTH (51)
6 3/4"
(172)
14"
(356)
2 3/8"
(60)
15"
(381)
13" 28 3/4" 10"
(330) (730) (254)
13"
(330)
A 2 1/2"
CHIMNEY WIDTH (64)
NOTE: Shown with front mounted internal blower with 6" (152) round discharge,
dashed line represents rear mount.
WIDTH W A
wolfappliance.com | 143
Downdraft Ventilation
Planning Information
Wolf Downdrafts can be installed with most Wolf cook- ELECTRICAL REQUIREMENTS
tops, but are not compatible with the Grill, Steamer, and
Installation must comply with all applicable electrical codes.
Fryer Modules. Downdrafts can be installed with Sealed
Burner Rangetop Models SRT304 and SRT366. Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
For installation with a Wolf cooktop, a minimum 251/8" (638)
this appliance is required. A ground fault circuit interrupter
deep flat countertop is required.
(GFCI) is not recommended and may cause interruption of
For installation with a Sealed Burner Rangetop or 30" (762) operation.
or 36" (914) contemporary cooktop, an accessory trim kit is
Certain installations may require the electrical supply be
required. Contact an authorized Wolf dealer for details. For
placed in an adjacent cabinet.
local dealer information, visit the find a showroom section
of our website, wolfappliance.com.
ELECTRICAL REQUIREMENTS
The remote-mounted control module can be positioned
Electrical Supply grounded, 120 VAC, 60 Hz
horizontally or vertically. It must be located within 9' (2.7 m)
of the downdraft assembly and a minimum 3" (76) from the Service 15 amp dedicated circuit
edge of the cooktop cutout. Receptacle 3-prong grounding-type
Consult a qualified HVAC professional for specific installa- Power Cord 21/2' (.8 m)
tion and ducting applications.
BLOWERS
Internal, in-line, and remote blowers are available through
an authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com. Refer to Ventilation Suggestions on
pages 154–157.
Internal blowers have a 6" (152) round discharge, can be
front or rear mounted, and can be discharged in any direc-
tion by rotating the blower box. In-line and remote blow-
ers have a 10" (254) discharge and can be discharged from
the front or rear.
Downdraft
INSTALLATION WITH STANDARD INSTALLED COOKTOP
W
DOWNDRAFT
CUTOUT WIDTH
2 11/16" (68) E
8 1/4" (210)*
COOKTOP CUTOUT
TOP VIEW
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.
CUTOUT WIDTH W
wolfappliance.com | 145
Downdraft Ventilation
Downdraft
INSTALLATION WITH FLUSH INSTALLED COOKTOP
W
DOWNDRAFT
CUTOUT WIDTH
2 5/16" (59) E
8 1/4" (210)*
COOKTOP CUTOUT
TOP VIEW
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.
CUTOUT WIDTH W
Downdraft
INSTALLATION WITH SEALED BURNER RANGETOP
W
DOWNDRAFT
CUTOUT WIDTH
2 11/16" (68) E
8 1/4" (210)*
RANGETOP OPENING
TOP VIEW
19" (483)
PLATFORM DEPTH
*6" (152) back from countertop cutout when internal blower is rear mounted.
NOTE: Internal blower 6" (152) round, side, rear, or bottom discharge. In-line and remote blower 10" (254) round, rear discharge.
Centerline indicates center of downdraft cutout.
CUTOUT WIDTH W
wolfappliance.com | 147
Pro Ventilation Hoods
Pro Hoods
MODELS
WALL HOODS
CHIMNEY OUTDOOR
ISLAND HOOD
ISLAND
HOOD LINER
19"/22" DEEP
Pro Hoods
LOW-PROFILE WALL HOOD
12"
(305)
10" (254)
4" (102)
W 22" (559)
WIDTH
18"
(457)
4" (102)
W 24" (610)
WIDTH
18"
(457)
4" (102)
W 27" (686)
WIDTH
WIDTH
LOW-PROFILE WALL HOOD W
30" (762), 36" (914), 42" (1067), 48" (1219)
wolfappliance.com | 149
Pro Ventilation Hoods
Pro Hoods
WALL CHIMNEY HOOD
18"
(457)
4" (102)
W 24" (610)
WIDTH
ISLAND HOOD
18"
(457)
4" (102)
W 34" (864)
WIDTH
HOOD LINER
12 1/8"
(308)
4" (102)
W 19 3/8" (492)
WIDTH 22 5/8" (575)
WIDTH
WALL CHIMNEY HOOD W
36" (914), 42" (1067), 48" (1219), 54" (1372)
ISLAND HOOD W
36" (914), 42" (1067), 54" (1372), 66" (1676)
HOOD LINER W
343/8" (873), 403/8" (1026), 463/8" (1178)
523/8" (1330), 583/8" (1483)
Pro Hoods
OUTDOOR WALL HOOD
13 9/16"
(346)
18"
(457)
4" (102)
W 33" (838)
WIDTH
WIDTH
OUTDOOR WALL HOOD W
36" (914), 48" (1219), 60" (1524)
wolfappliance.com | 151
Pro Ventilation Hoods
Planning Information
Pro Ventilation Hoods and hood liners are recommended RECIRCULATING APPLICATION
for use with all Wolf cooking appliances. Wall hoods should
Low-profile, 24" deep, and 27" deep wall hoods with an
be at least as wide as the cooking surface and island hoods
internal blower (600 CFM or less), 30" (762) and 36" (914)
should be 3" (76) wider on each side.
widths only, can be used in a non-ducted application with
For optimal performance in wall hood applications, a Pro a recirculating filter. In this installation, kitchen air is puri-
27" deep wall hood is recommended for use with ranges fied through the filters and returned as clean air into the
and rangetops with a charbroiler or griddle. room. A recirculation kit, available through an authorized
Wolf dealer, is required.
Installation of all Pro Hoods except the outdoor wall hood
should be 30" (762) to 36" (914) from the bottom of the
hood to the countertop. Installation of the outdoor wall CUSTOM HOOD APPLICATIONS
hood should be 36" (914) to 42" (1067) from the bottom of
Wolf Pro hood liners are for use in custom hood applica-
the hood to the countertop.
tions. The decorative hood can be created out of wood,
Pro Hoods and hood liners are shipped without a blower plaster, tile, or metal. The shape of the hood is not critical,
assembly. Internal, in-line, and remote blowers are avail- however, the bottom of the hood and liner must be on
able through an authorized Wolf dealer. For local dealer the same plane. The height of the liner does not need to
information, visit the find a showroom section of our accommodate the entire height of the decorative hood.
website, wolfappliance.com. The blower will vary in size
and is dictated by the cooking unit, volume of air, and
ELECTRICAL REQUIREMENTS
length of the duct run. Refer to Ventilation Suggestions
on pages 154–157. Installation must comply with all applicable electrical codes.
Pro Hoods accommodate a 10" (254) round duct. Low- Locate the electrical supply as shown in the illustrations
profile wall hoods allow for an adjustable discharge. All on the following page. A separate circuit servicing only this
other Pro Hoods have a vertical discharge. For the 24" and appliance is required.
27" deep wall hoods, a horizontal discharge kit is available For the outdoor wall hood, a ground fault circuit inter-
through an authorized Wolf dealer. rupter (GFCI) is required to reduce the risk of electrical
Consult a qualified HVAC professional for specific installa- shock.
tion and ducting applications.
ELECTRICAL REQUIREMENTS
Optional stainless steel duct covers in a variety of heights
are available for Pro wall and island hoods through an Electrical Supply grounded, 120 VAC, 60 Hz
authorized Wolf dealer. Service 15 amp dedicated circuit
Installation
LOW-PROFILE / 24" DEEP / 27" DEEP WALL HOOD OUTDOOR WALL HOOD
6" 6"
E (152) E (152)
5" 5"
(127) (127)
30" (762) TO 36" (914) BOTTOM EDGE TO COUNTERTOP 36" (914) TO 42" (1067) BOTTOM EDGE TO COUNTERTOP
6"
E (152)
5"
(127)
ISLAND HOOD
ELECTRICAL LOCATION
THROUGH TOP OF HOOD
HOOD LINER
DECORATIVE HOOD
E
121/2" 75/8"
(318) (194)
wolfappliance.com | 153
Ventilation Suggestions
Blower Assemblies
For Wolf Ventilation Hoods and Downdrafts that do not Ventilation suggestions on the following pages provide
include a blower assembly, an internal, in-line, or remote Wolf product CFM and blower options for each Ventilation
blower assembly must be selected to accommodate the Hood and Downdraft.
cooking appliance, CFM requirements, and homeowner
Refer to the illustrations below for dimensions of Wolf in-
preferences. Internal, in-line, and remote blowers are avail
line and remote blowers. Installation instructions shipped
able through an authorized Wolf dealer. For local dealer
with each Wolf ventilation product provide detailed
information, visit the find a showroom section of our
specifications. These instructions can also be found on our
website, wolfappliance.com.
website, wolfappliance.com/specs.
24 3/8" 24 7/8"
(619) (632)
11 3/4"
(298) 18"
(457) 12"
18 1/2" (305)
(470)
4 1/2"
(114)
8"
(203)
211/2"
(546) 12 1/4"
(311) 22" 18"
(559) (457)
21" (533)
20 3/4" 10"
(254)
28 1/4"
(527) 29 1/2"
(718) (749)
10" (254) 10" (254)
DIAMETER DIAMETER
15 1/2" 14 3/4"
(375) 29 1/2"
(394) 24 1/2" (749)
(622)
10 3/8"
14" (264)
(356)
4 3/4"
24 3/4" (121) 25" 7 1/4"
(629) (635) (184)
DF30450/S/P 500
GAS RANGE
GR304 500
INDUCTION RANGE
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
wolfappliance.com | 155
Ventilation Suggestions
INTERNAL BLOWER (CFM) 300 INT* 400 INT* 500 INT 600 INT 800 INT 1200 INT
COOKTOP HOOD
PW302210 PW362210 •
PW422210 PW482210 •
PRO 24" WALL HOOD
PW482418 PW542418 • • • • •
PW602418 PW662418 • • • • •
PRO 27" WALL HOOD
PW482718 PW542718 • • • • •
PW602718 PW662718 • • • • •
PRO WALL CHIMNEY HOOD
PWC362418 PWC422418 • • • • •
PWC482418 PWC542418 • • • • •
PRO ISLAND HOOD
PI363418 PI423418 • • • • •
PI543418 • • • • •
PI663418 • • • • •
PRO HOOD LINER
PL461912 PL462212 • • • • •
PL521912 PL522212 • • • • •
PL581912 PL582212 • • • • •
OUTDOOR WALL HOOD
IN-LINE / REMOTE BLOWER (CFM) 600 IL 1100 IL 600 REM 900 REM 1500 REM
COOKTOP HOOD
PW302210 PW362210 • • • • •
PW422210 PW482210 • • • • •
PRO 24" WALL HOOD
PW302418 • • • • •
PW602418 PW662418 • • • • •
PRO 27" WALL HOOD
PW302718 • • • • •
PW602718 PW662718 • • • • •
PRO WALL CHIMNEY HOOD
PWC362418 PWC422418 • • • • •
PWC482418 PWC542418 • • • • •
PRO ISLAND HOOD
PI363418 PI423418 • • • • •
PI543418 • • • • •
PI663418 • • • • •
PRO HOOD LINER
PL461912 PL462212 • • • • •
PL521912 PL522212 • • • • •
PL581912 PL582212 • • • • •
OUTDOOR WALL HOOD