Professional Documents
Culture Documents
SMARTENG TECH
PRODUCT CATALOGUE
Website:www.smartenggroup.com
1302(A),13/F,Jiafu commercial Centre,982
Guangdong Road,Mong Kok,Kowloon.
-1-
COMPANY INSTRODUCTION
Core Values
Integrity:
Honesty, fairness & Transparency in our
Business Dealings & Conduct
Innovation:
Developing new products & expanding technical
support to improve service.
Excellence:
Striving to achieve highest standard in work,
process & quality of materials.
S
cooperation:
Excellence through Team work in Management, M
A
Employees & Departments.
R
SMARTENG TECH T
Hangzhou Smarteng Wanwei Technology Co.,Ltd, is one of the professional
E
N
manufacturers of power fittings and safety products in China. Smarteng has more
than 15 years experience in Power Fitting and Safety Product backed by a team of
experts and professionals with more than 25 years in this field
G
Smarteng has two manufacturer bases. One is located in Wenzhou, the other is
in Fuzhou, covers more than 60,000 square meter, more than 200 advanced
machines and equipments, more than 500 skilled workers and 80 professionals.
T
the qualify supplier for China State Grid, are the committee member of Insulation
Piercing Clamp International standard, owned over 40 national invention patents,
are awarded National High-Tech Enterprise. Our products exported to over 30
countries and regions such as, Russia, Brazil, Mexico, Indonesia, Argentina, India,
E
Australia, Southeast Asia, Middle East, Africa and so on.
Smarteng always embrace change and the new ideas, opportunities, and
growth .we aim to make a difference in the communities where we live and work,
with an aspiration to improve our lives.
-2-
Product Center
Power fitting
√Power Transmission & Distribution Hardwares & Fittings --------------------------------- P1-38
√Cable Lugs & Connectors ----------------------------------------------------------------------------- P39-57
√Earthing and Lightening -------------------------------------------------- P58-58
√Preformed Line product ------------------------------------------------------------------------------- P59-77
√Insulation piercing connectors ----------------------------------------------------------------------- P78-79
√Cable accessories ---------------------------------------------------------------------------------------- P80-95
√Electric Tools ----------------------------------------------------------------------------------------------- P96-102
Plastic products
√cable ties ------------------------------------------------------------------------------------------------------- P123-125
√clips ------------------------------------------------------------------------------------------------------------- P126-126
√glands ---------------------------------------------------------------------------------------------------------- P127-128
√cold pressing wiring terminal and connectors ---------------------------------------------------- P129-134
√Terminal blocks ---------------------------------------------------------------------------------------------- P135-138
Insulators
√Composite insulators --------------------------------------------------------------------------- P147-153
√Porcelain insulators ----------------------------------------------------------------------------- P154-163
New Products
√Smart Grid --------------------------------------------------------------------------------------------------- P164-169
√Smart intelligent water leakage control system ------------------------------------------------- P170-179
-3-
www.smartenggroup.com
Power Fittings
Part Three
Earthing and Lightening
1、 ER
2、 Coupling LJ
3、 Drill ZT
4、 Driving Head
- 58 -
High Voltage Products
High Voltage products
High-strength insulator
Upper contact---Ag/Ag,
stainless steel spring provides high contact pressure
High-strength silver-plated cast-copper trunnion Toggle jointGuarantee the reliable release after being switched off
Preventing the tube fuse wobbling in closing
For trunnion sleeve, the pipe is fixed at the hinge during closing.
Stainless steel spring board, for rapidly drawing the fuse wire out
General
Drop-out fuse and load-drawing drop-out fuse are the outdoor high voltage protective devices. They are mounted on the
high voltage side of distribution transformer or main or branch distribution circuits, to protect against short circuit and
overload and make and break load current of transformer and circuit. Hereinto, drop-out fuse is made up of insulator support
and fuse tube, its static contact is mounted at both ends of insulator support, and the moving contact is mounted at the both
terminals of fuse tube that is composed of inner arc extinguishing tube and outer phenol aldehyde laminated paper tuber or
epoxy glass cloth tube. The load-drawing drop-out fuse is provided with additional reinforced auxiliary contact and arc chute,
When the drop-out fuse works normally, the fuse tube forms the closing position by using the tension of fuse wire. If the
system has the trouble, the fault current will cause that the fuse is blown out rapidly, and bring electric arc, the arc
extinguishing tube is heated for arc, to decompose much gas, and produce high pressure in the tube, then, longitudinally
blown arc is formed along the pipeline, and the arc is extinguished for rapid lengthening. After the fuse wire is blown out, the
lower moving contact misses the pulling force and turns downwards, the locking mechanism releases the fuse tube to make it
drop out and form the obvious breaking position. When need to draw the load, the moving contact is drawn out with the
insulating rod, at this moment, the main moving and static contacts still keep contact, if need the insulation, the contact is
also drawn out with the insulating rod, meanwhile, the auxiliary contact separates, thus, electric arc presents among auxiliary
contacts, and the electric arc is drawn out in the slit of arc chute, at the same time, the arc chute produces the gas, when the
- 139 -
High Voltage Products
- 140 -
High Voltage Products
(二)Lightning Arresters
ZINC-OXIDE ARRESTER
Usage feature
General
Zno lighting arrester is a kind of world
advanced over-voltage protector at present,
due to its core components of resistance
applying Zno and other metal oxide to
make of, co mp a ri n g with tra d it ti o na l
carborundum arrester, it improves greatlyV-A
characteristics of resistance increases the
getting trough ability of resistance, thereby
it brings fundamental change to features of
arrester.
Under normal working voltage, the current
passing arrester only is uA class, when
bearing over voltage,the execellent non-
linear V-A features of arrester would make
effect, the curent passing through the
arrester increase high to th-ousands of
Ampere instant, the arrester is under getting
through state, to relesae over-voltage
energy, therefore it effective limits the
damage to power transmis-sion equipments
due to over Voltage.
Zn lighting arrester is a kind of protecting equipment preventing electric equipments in AC pewer system from high voltage and over-
voltage operation.
Model Description
Y H □ □ □ □ □ -□ /□ □
- 141 -
High Voltage Products
Main technical parameters
System Rated Continuous operating U1mAD.C Nominal discharging current Power frequency 2ms square wave
Product model
voltage kV voltage kV voltage kV ≮ kV residual voltage ≯ Kv reference voltage ≥ kV discharge capacity A
YH1.5W-0.28/1.3 0.22 0.28 0.24 0.60 1.3 0.28 75
YH1.5W-0.5/2.6 0.38 0.5 0.42 1.20 2.6 0.5 75
YH5WS-10/30 6 10 8 15 30 10 100,150
YH5WZ-10/27 6 10 8 15 27 10 100,400
YH5WR-10/27 6 10 8 15 27 10 100,400
YH5WS-17/50 10 17 13.6 25 50 17 100,150
YH5WZ-17/45 10 17 13.6 24 45 17 400
YH5WR-17/45 10 17 13.6 24 45 17 400,60
YH5WT-42/120 27.5 42 34 65 120 42 400,60
YH5WZ-51/134 35 51 41 73 134 51 400,60
YH5WZ-53/134 35 53 41 75 134 53 400,60
YH1.5W-30/85 35 30 30 48 85 330 400,60
YH10W-100/260 110 100 78 145 260 100 600,800
YH10W-102/266 110 102 80 148 266 102 600,800
YH1.5W-72/186 110 72 58 103 186 72 600,800
YH1.5W-73/200 110 73 60 105 200 73 600,800
YH10W-200/520 220 200 156 290 520 200 600,800
YH10W-204/532 220 204 159 296 532 204 600,800
YH1.5W-144/320 220 144 116 205 320 144 600,800
ZINC-OXIDE ARRESTER
- 142 -
High Voltage Products
5kA Gapless arrester electrical character
Aparkover voltage(KT)
Product model Rated voltage(KA) Mcov (KT) Power frequency Lightning impulse Lightning current impulse 2000μs square wave impluse 4/10μs high
current withstand current impulse
Y5C-3 3 2.55 5.0 7.8 9 100 65
Y5C-6 6 5.1 10.0 15.5 18 100 65
Y5C-9 9 7.65 16.5 24.5 27 100 65
Y5C-12 12 1.2 21.0 32.6 36 100 65
Y5C-15 15 12.7 25.0 38.8 45 100 65
Y5C-18 18 15.3 31.0 48.1 54 100 65
Y5C-21 21 17.0 34.0 52.7 63 100 65
Y5C-24 24 19.2 39.0 60.5 72 100 65
Y5C-27 27 21.9 45.0 69.8 81 100 65
Y5C-30 30 24.4 50.0 77.5 90 100 65
Y5C-33 33 26.8 55.0 85.3 99 100 65
Y5C-36 36 29 60.0 93.0 108 100 65
Y5C-42 42 34.1 70.0 108.5 126 100 65
- 143 -
High Voltage Products
三.Disconnecting Switch
General
GW4 outdoor disconnenting switch is AC 50Hz outdoor HV equiments, there are 40.5kV, 72.5kV, 126kV and 252kV rated
voltage grade for it, it can open and close the high voltage circuit under no-load conditions and perform the electric isolation
of tested high voltage bus, circuit breaker, charged high-voltage circuit, etc., it also can make and break the small capacitance
or inductive current.
Structure defnation
The disconnecting switch consists of base, insulating post, conductive part and operating mechanism. Each pole has two
posts, and at the top of post, there are two conductive blades, the contact of two blades contacts are in the middle of two
posts; and at the bottom of post, there are bearing sheathes; by the auction of operating mechanism, the blade is able to
The disconnecting switch is of single-pole type, however, it can be formed into the interlinked three-pole type through
connecting the three poles with the connection rod. It is equipped with CS11 type or CS17 type manual operation mechanism,
hereinto, CS17 is used for the disconnecting switch with earthing device. In addition, CJ16 motor mechanism may be
On the basis of the abovementioned structure instruction, it is easy to see that the disconnecting switch has reasonable
structure and flexible operation, the single-pole type or three-pole type is used in available; it is featured with convenient
installation, large clearance of open contact blades and reliable insulation. According to customers' needs, it may be provided
- 144 -
High Voltage Products
Rated Rated 4S heat steady Shock steady Impulse withstand voltage (kV) Power-frequency withstand voltage(kV)
Type
voltage kV current (A) current (kA) current (kA) TO earth Across the isolating distance TO earth Across the isolating distance
GW4-40.5 35 630 1250 20 31.5 40 50 80 100 185 215 80 90
2000
GW4-72.5 66 630 1250 20 31.5 40 50 80 100 325 375 140 160
2000
GW4-126 110 630 1250 20 31.5 40 50 80 100 450 550 185 210
2000
GW4-145 145 630 1250 20 31.5 40 50 80 100 585 715 240 275
2500 2500
GW4-252 220 2000 2500 31.5 40 50 50 100 125 950 1050 395 460
3150
General
GW5 outdoor disconnenting switch is AC 50Hz outdoor HV equiments, there are 40.5kv, 72.5kv and 126kv rated voltage
grade for it, it can open and close the high voltage circuit under no-load conditions and perform the electric isolation of
tested high voltage bus, circuit breaker, charged high-voltage circuit, etc., it also can make and break the small capacitance or
inductive current.
- 145 -
High Voltage Products
Structure defnation
The disconnecting switch consists of base, insulating post, conductive part and operating mechanism. Each pole has a pair of
V-shaped posts, and at the top of post, there are two conductive blades, the contact of two blades contacts are in the middle
of two posts; at the bottom of post, there are bearing sheathes and bevel gear for driving; by the auction of operating
mechanism, the blade is able to rotate 90O,so as to meet the opening and closing requirements.
The disconnecting switch is of single-pole type, however, it can be formed into the interlinked three-pole type through
connecting the three poles with the connection rod. It is equipped with CS17 type manual operation mechanism, hereinto,
CS17D is used for the disconnecting switch with earthing device. In addition, CJ16 motor mechanism may be equipped
On the basis of the abovementioned structure instruction, it is easy to see that the disconnecting switch has reasonable
structure and flexible operation, the single-pole type or three-pole type is used in available. In addition, it may be installed
on side or installed reversely; it is featured with large clearance of open contact blades and reliable insulation. According to
customers' needs, it may be provided with the single-side earthing mode or double earthing mode.
Main technical parameters
Rated Rated 4S heat steady Shock steady Impulse withstand voltage (kV) Power-frequency withstand voltage(kV)
Type
voltage kV current (A) current (kA) current (kA) TO earth Across the isolating distance TO earth Across the isolating distance
GW5-40.5 35 630 1250 20 31.5 40 50 80 100 185 215 80 90
2000
GW5-72.5 66 630 1250 20 31.5 40 50 80 100 325 375 140 160
2000
GW5-126 110 630 1250 20 31.5 40 50 80 100 450 550 185 210
2000
GW5-145 145 630 1250 20 31.5 40 50 80 100 585 715 240 275
2500 2500
- 146 -
Insulators
Insulators
1、Composite insulators
- 147 -
Insulators
COMPOSITE
INSULATOR
End fittings are steel or forged iron. They are
crimped directly to the rodby a special process
originated by PHOENIX, and later adopted by
many other producers. the rod’s inherent tensile
strength. It requires no intermovement of the parts
to achieve high stength, nor does it introduce
potting compounds or adhesives.
- 148 -
Insulators
General
The tension composite insulator is suitable for the polluted area, especially for the severe pollution area, featured with high
tensile strength, perfect antip- ollution performance, convenient operation and installation. It adopts various fitting
Structure height
Insulating (dry arcing) distance
φ18
φ92
18
16
Creepagedistance
- 149 -
Insulators
Main Technical Parameters
Rated Rated mechanical Shed dia× Structure height Insulating Min nominal creepage Lightning full wave impulse 1min Power frequency
Spec. & model
Voltage(kV) load (kV) Shed no(mm) ±10(mm) distance distance (mm) withstand voltage kV wet withstand voltage
FNB4-1/70XX 1~3 70 92×2 260 80 235 30 7
FNB4-6/70XX 6 70 92×3 300 120 335 60 25
FNB4-10/70XX 10 70 92×4 340 160 435 95 45
FNB4-15/70XX 15 70 92×5 380 200 535 110 60
FNB4-20/70XX 20 70 92×6 420 240 635 130 70
FNB4-24/70XX 24 70 92×7 460 280 735 150 75
FNB4-28/70XX 28 70 92×8 400 320 835 180 85
FNB4-33/70XX 33 70 92×9 540 360 935 205 90
FNB4-35//70XX 35 70 92×10 580 400 1035 230 95
General
This product for badly polluted areas, high mechanieal nical tension load, long small volume, unbreakable, anli-bend higt
- 150 -
Insulators
Rated Rated mechanical Structure Insulating distance Min nominal creepage Lighting impulse withstand 1min P.F. wet withstand voltage
Name
Voltage(kV) load (kV) height H.(mm) li.(mm) distance li. (mm) voitage (peak) (kV) (effective value) not less than
FXBW4-10/70 10 70 360 180 480 105 42
FXBW4-10/100 10 100 400 180 480 105 42
FXBW4-35/70 35 70 650 455 1250 230 95
FXBW4-35/100 35 100 690 455 1250 230 95
FXBW4-66/70 66 70 930 700 2100 410 185
FXBW4-66/100 66 100 970 700 2100 410 185
FXBW4-110/70 110 70 1200 1015 3200 550 230
FXBW4-110/100 110 100 1240 1015 3200 550 230
FXBW4-220/100 220 100 2155 1930 6300 1000 395
FXBW4-220/160 220 160 2240 1930 6300 1000 395
FXBW4-330/100 330 100 2990 2610 9075 1425 570
FXBW4-330/160 330 160 2990 2610 9075 1425 570
FXBW4-330/210 330 210 2990 2610 9075 1425 570
FXBW4-500/160 500 160 4450 4100 13750 2050 740
FXBW4-500/210 500 210 4450 4100 13750 2050 740
Precautions in installation
1. The insulator should be handled with care in carrying or installing, to avoid it colliding and fractioning with parts like the conductor, wiring board, tool as
well as sharp material.
2. When the composite insulator is hung, the rope should be tied at the end accessory (fitting), rather than the shed or sheath, if the rope has to touch the
shed and sheath, the contact part should be covered with the soft cloth.
3. Even if the material of this insulator shed has the rat-repelling property, some rat-proof measures should be still taken in the storing place just in case.
The damaged shed should be rejected.
- 151 -
Insulators
General
This product is applied to high voltage power ine service, with features of good hydrophobicity, anti-ageing, antiqeakage
trace and electrical erosion proof, tensile strength and bending strength, strong mechanical strength, shock resistance good
quakeproof and brittle failure proof,light weight, easy to install, and the installation size of top and base are the same with
Rated Rated mechanical Structure Insulating distance Min nominal creepage Lighting impulse withstand P.F.wet withstand voltage
Product model
Voltage(kV) load (kV) height H.(mm) li.(mm) distance li. (mm) voitage (peak) (kV) (virtual value)(kV)
FPQ-10/3T 10 4 215 120 300 95 42
FPQ-10/4T 10 4 250 160 360 105 42
FPQ-20/12.5 20 12.5 350 230 560 185 85
FPQ-35/4 35 4 430 315 1050 265 95
- 152 -
Insulators
General
This product is applied to high voltage power ine service, with features of good hydrophobicity, anti-ageing, anti-leakage
trace and electrical erosion proof, tensile strength and bending strength, strong mechanical strength, shock resistance good
quakeproof and brittle failure proof,light weight, easy to install, and the installation size of top and base are the same with
2、Porcelain insulators
- 153 -
Insulators
- 154 -
Insulators
- 155 -
Insulators
- 156 -
Insulators
- 157 -
Insulators
- 158 -
Insulators
- 159 -
Insulators
- 160 -
Insulators
- 161 -
Insulators
- 162 -
Insulators
- 163 -