Professional Documents
Culture Documents
3 Phase AC Contactors
AC Motor Reversing
Contactors
DC Motor Reversing
Contactors
www.crydom.com
DRA Series Contactors
DRA Series
3 Phase AC Contactors & AC Motor Reversing Contactors
Ideal for applications up to 2 Horse Power
45 mm wide 3 phase, 2 or 3 controlled legs versions available
62 mm wide motor reversing DIN rail mountable versions available
400 VAC and 480 VAC Operating Voltage available
5 VDC, 24 VDC, 48 VAC, 120 VAC & 230 VAC Input Control Voltage options available
Protective Forward/Reverse interlock built-in function for Motor Reversing
UL and IEC Resistive & Motor ratings available
LED Status indicator for Input Control Voltage
No heat sink required & cage style screw terminals for easy installation & reliable wire connection
Input Specifications (A) DRA3P48Dx DRA3P48Ex DRA3P48Cx DRA3P48Bx DRA3P48Ax DRA3R4xDx DRA3R4xEx DRA3R4xCx DRA3R4xBx DRA3R4xAx
Input Control Voltage Range 4-6 VDC 18-28 VDC 36-60 VAC 90-140 VAC 200-265 VAC 4-6 VDC 18-32 VDC 36-60 VAC 90-140 VAC 200-265 VAC
Rated Input Control Voltage 5 VDC 24 VDC 48 VAC 120 VAC 230 VAC 5 VDC 24 VDC 48 VAC 120 VAC 230 VAC
Minimum Turn-On Voltage 4 VDC 18 VDC 36 VAC 90 VAC 200 VAC 4 VDC 18 VDC 36 VAC 90 VAC 200 VAC
Must Turn-Off Voltage 2 VDC 4 VDC 10 VAC 20 VAC 60 VAC 2 VDC 4 VDC 10 VAC 20 VAC 60 VAC
Maximum Reverse Voltage 6 VDC 28 VDC N/A N/A N/A 6 VDC 32 VDC N/A N/A N/A
Input Control Current Range [mA] 17-35 15-25 7.5-13.5 5-8 4.5-5.7 15-30 15-18 6-10 5-8 5.5-7.7
Nominal Input Impedance [Ohm] 120 1.2 K 4.2 K 16 K 46 K 100 1.2 K 4.8 K 16.4 K 36 K
Maximum Turn-On Time (K) 1/2 cycle 1/2 cycle 20 msec 20 msec 20 msec 100 ± 20 msec 100 ± 20 msec 100 ± 30 msec 100 ± 30 msec 100 ± 30 msec
Maximum Turn-Off Time 1/2 cycle 1/2 cycle 30 msec 30 msec 30 msec 10 msec 10 msec 20 msec 20 msec 20 msec
General Notes
(A) All parameters at 25ºC unless otherwise specified (H) AC-53a ratings for DRA3P48x2 (A,B & C suffix) are 0.25 KW @ 240 VAC, 0.37 KW @ 400
(B) Overvoltage protection included VAC & 0.55 KW @ 480 VAC
(C) Based on a vertical mounting position operation (J) AC-53a ratings for DRA3Pxxx2 (A,B & C suffix) is 0.37 KW @ 480 VAC
(D) Ratings are for 0 mm air gap to adjacent similar parts unless otherwise specified (K) Random switching Turn-On time is 0.1 msec (3P with E or D suffix only)
(E) Resistive Load Current rating for DRA3P48x4 (A, B & C suffix only) is 3.4 A (L) For low ambient temperature operation use Rated Input Control Voltage
(F) AC-53a Load Current rating for DRA3P48x2 (A, B & C suffix only) is 1.6 A @ 480 VAC and 1.8 A (M) 3 Controlled legs vesions only
@ 400 VAC
(G) 3 Channels operate simultaneously on DRA3P48xxx models. 2 Channels operate simultaneously
on DRA3P48xxx2 models & DRA3R models
Complete specifications of these & other Crydom products available at: www.crydom.com
DRA Series Contactors
1.0
Function Control Voltage Switching Type (Only for 3P)
3P: 3 Phase D: 4-6 VDC Blank: Zero Voltage Turn-On 0.0
3R: Reversible E: 18-28 VDC R: Instantaneous Turn-On 0 10 20 30 40 50 60
A: 200-265 VAC Ambient Temperature (°C)
B: 90-140 VAC
C: 36-60 VAC Temp. DRA3P48x2 DRA3P48x4 DRA3R4xx2 DRA3R4xx4
Required for valid part number
40°C 1 HP (0.75 KW (H)) 2 HP (0.75 KW) 1 HP (0.75 KW) 2 HP (1.5 KW)
For options only and not required for valid part number 60° ¾ HP (0.55 KW (J) ) 1 HP (0.37 KW) ¾ HP (0.55 KW) 1 HP (0.75 KW)
DRA3P DRA3R
SSR-DC-4
SSR-AC-4A 480V 4.2A
480V 4.2A 2HP@480VAC
2HP@480VAC
2.91
[73.9]
2.91
[73.9]
2.22 2.22 ASSEMBLED
+F
L1 L2 L3
T1 T2 T3
CONTROL
IN MEXICO
AC LINE
5VDC
ASSEMBLED
LOAD
T1 T2 T3
[56.3]
L1 L2 L3
1102
-
-A1 +A2
IN MEXICO
DRA3R48D4
CONTROL
AC LINE
[56.3]
230VAC
LOAD
1.48
+R
1102
DRA3P48E4 R
1.48
[37.7]
[37.7]
2.04
1.37 3.53 [51.7]
3.53
[34.9] [89.6] 2.43
[89.6]
1.77 [61.7]
[44.9] Wiring Diagram
S1
Wiring Diagram F
~/+ -/~ -
T1 Source
R
T2 ~/- A
T3 S2
~/+ A
(M)
T1 L1
T1 T1
T2 L1
T3 T2 L2 T2
MOTOR L2
T3 L3 T3
T1 L3
MOTOR T2
T3
Block Diagram
Questions? America Tel.: +1 (877)502 5500 EMEA Tel.: +44 (0) 1202 416170 Asia Tel.: +86 (21) 2306 1648
Call or e-mail: e-mail: sales@crydom.com e-mail: sales-europe@crydom.com e-mail: sales-cn@crydom.com
DRA Series Contactors
DRA Series
DC Motor Reversing Contactors
54 mm wide motor reversing DIN rail mountable contactor package
90 VDC & 180 VDC Rated Operating Voltage
5 to 15 VDC & 15 to 32 VDC Input Control Voltage options available
Operational Current
Output Specifications (A) DRA4D100x12 DRA4D250x6 Part Number Nomenclature 6: 6 Amps/¼ HP @ 180 VDC
Operating Voltage Range [VDC] 1-100 1-250 Operating Voltage Range (250 suffix only)
Rated Operating Voltage [VDC] 90 180 100: 1-100 VDC 12: 12 Amps/¼ HP @ 90 VDC
Resistive Load Current (UL508/IEC 60947, DC-1) @ 40 °C [A] (D) 12/12 6 (N) /6 Series 250: 1-250 VDC (100 suffix only)
Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.001 0.02
Maximum Surge Current (10 ms) [A]
Maximum On-State Voltage Drop @ Rated Current [VDC]
110
0.1
91
0.1
DRA 4D 100 D 12
Maximum On-State Resistance (RDS-On) [mOhms] 10.5 48 Function Control Voltage
Maximum Operations per sec 5 5 4D: H-Bridge D: 5 VDC
Ratings per UL508 [HP] ¼ HP, 4 FLA @ 90 VDC ¼ HP, 2 FLA @ 180 VDC E: 24 VDC
Ratings per IEC 60947, DC-3 [KW] 0.36 KW, 4 FLA @ 90 VDC 0.36 KW, 2 FLA @ 180 VDC
DRA4D
Input Specifications (A) DRA4DxxxDxx DRA4DxxxExx
Input Control Voltage Range [VDC] 5-15 15-32
Mechanical Dimensions
Rated Input Control Voltage [VDC] 5 24
Tolerances: ± 0.02 in / 0.5 mm - All dimensions are in: inches [millimeters]
Minimum Turn-On Voltage [VDC] 5 15
Must Turn-Off Voltage [VDC] 2.5 2.9
Input Control Current Range [mA] 16-24.5 20.5-22
Nominal Input Impedance see note (P) see note (P) SSR-DC-E12
ASSEMBLED
General Specifications (A) Parameters 1.89
+F - +R
CONTROL
IN MEXICO
LOAD
24VDC 1102
[48.1] DRA4D100D12 R
General Notes +
M1 +
(A) All parameters at 25°C unless otherwise specified
- -
(D) Ratings are for 0 mm air gap to adjacent similar parts, except for DRA4D250x6 (see note M) S1 M2
(L) For low ambient temperature operation use Rated Input Control Voltage F
(N) Resistive Load Current rating for DRA4D250x6 is 5.5 A @ 0 mm air gap. For maximum ratings + - -
use 45 mm air gap R
S2
(P) Input circuit incorporates active current limitation
Block Diagram
FORWARD INPUT
Derating Curve Temp. DRA4D100x12 DRA4D250x6
STATUS CONTROL
40°C ¼ HP 4 FLA @ 90 VDC ¼ HP 2 FLA @ 180 VDC INDICATOR CIRCUIT +
60°C ¼6 HP 3 FLA @ 90 VDC ¼6 HP 1 FLA @ 180 VDC
Photo
12.0 F LED
receiver
10.0 M1
Photo
Load Current (Amps)
8.0 LED
receiver
6.0
DRA4D100x12 - INTERLOCK -
4.0 DRA4D250x6
Photo
LED
REVERSE receiver
2.0
STATUS
INDICATOR M2
0.0
0 10 20 30 40 50 60 Photo
R LED
receiver
Ambient Temperature (°C)
Complete specifications of these & other Crydom products available at: www.crydom.com
AMERICAS United States & Canada Southern & Central
2475 Paseo de las Americas American Countries
5014 San Diego, CA 92154 Tel. : +1 (877) 502 5500
Sales Support Fax : +1 (619) 210 1590
Tél. : +1 (877) 502 5500 sales@crydom.com
Fax : +1 (619) 210 1590
sales@crydom.com
Technical Support
Tél. : +1 (877) 702 7700
support@crydom.com
EUROPE, MIDDLE EAST United Kingdom Austria & Switzerland Germany Netherlands
Everdene House, Deansleigh Road Tel. : +44 (0) 1202 416170 Tel. : +49 (0) 180 3000 506 Tel. : +31 (0) 71 582 0068
& AFRICA Fax : +44 (0) 1202 416171
Wessex Fields, Bournemouth, Fax : +44 (0) 1202 416171 Fax : +44 (0) 1202 416171
Dorset BH7 7DU vertrieb@crydom.com vertrieb@crydom.com sales-europe@crydom.com
Sales Support
Tel. : +44 (0) 1202 416170 Belgium Italy Middle East, Africa
Fax : +44 (0) 1202 416171 Tel. : +32 (0) 2460 4413 Tel. : +39 (0) 2360 26567 & Other European
sales-europe@crydom.com Fax : +44 (0) 1202 416171 Fax : +44 (0) 1202 416171 Countries
sales-europe@crydom.com sales-europe@crydom.com Tel. : +44 (0) 1202 416170
Technical Support
Fax : +44 (0) 1202 416171
support-europe@crydom.com
France Spain sales-europe@crydom.com
Tel. : +33 (0) 1707 91389 Tel. : +434 902 876 217
Fax : +44 (0) 1202 416171 Fax : +44 (0) 1202 416171
sales-europe@crydom.com sales-europe@crydom.com
CAT/CR/DC/EN
Distributed by :