You are on page 1of 33
ENVIRONMENTAL MONITORING REPORT | (JULY 2023) BHUBANESWAR, ODISHA. BIE ener cromte ine iyans INDEX Sl.No. Descriptions Page No. 1 Preamble 02 2. Details of Monitoring/ Sampling Stations 03-05 3. Results 06-30 TABLE Table No. Particulars Page No. a eee zy 1a ‘Scope of Work 24 Details of AAQ Monitoring Stations 3 22 Details of Fugitive Emission Monitoring Stations 3 23 Details of Noise (Ambient & Work Zone) Monitoring Stations 4 24 Details of Water Sampling Stations 4 25 Details of Meteorological Monitoring Stations 5 ANNEXURE Annexure No. | Descriptions Page No. a Meteorological Monitoring Report 68 2. ‘Ambient Air Quality Monitoring Report 9-15 3. Fugitive Emission Monitoring Report 16-19 4 ‘Ambient Noise Monitoring Report 20-21 5. ‘Work Zone Noise Monitoring Report 22:23, 6. Results of Surface Water Analysis 24-26 7 Result of Flow of Water Measurement 27-28 8 Result of Surface Run Off water Analysis 23-30 EMC Pvt Lid, Paget = ORME anger chromite ine 1.0 PREAMBLE Odisha Mining Corporation Limited (hereinafter termed as OMC), 2 Government of Odisha undertaking has engaged M/s Centre For Envotech And Management Consultancy Pvt. Ltd. (hereinafter termed as CEMC), Bhubaneswar, Odisha for carrying out various Environmental Monitoring and Analysis Work in different mine leases of OMC located in the district of Jajpur, Keonjhar and Sundergarh The laboratory division of M/s CEMC is assessed and Accreditated in accoradance with standard 'SO/EC 17025:2017 (General requirements for the Competence of Testing & Calibration ‘aboratories) in the field of TESTING by National Accreditation Board for Testing and Calibration Laboratories (NABL). The NABL Certificate Number is TC-6646 and is valid until 26.01.2024 Environmental Monitoring& Analysis Work of OMC includes monitoring analysis of various attributes of Air Quality, Water Quality, Noise Level, Waste Water Quality, Vehicular Emission and Soll Quality. Apart from these, various ether activities such as suggestions to control the pollution, This report presents the Environmental related data generated from the core and buffer zone of Bangur Chromite Mine of M/S OMC Ltd. located in district of Keonjhar, Odisha during “July 2023”. ‘Scope of the Work ‘The scope of work during “July 2023s as follows: | Ao, Partlutars | rrequency of monitoring | No.of stations | |. Ambient airquaity a _WeeieyTwice 2. Fugitive Emission (F) Weekly Twice 6 3. Ambient Noise Level Survey (N} es Monthly Once cr] 4. Work Zone Noise Level ‘Survey (WZN) Monthly Once 3 Surface Water Quality (SW) Se ES ee ere 6. Surface water Flow Messurement(SWEM) Monthly Once fra Meteorological Monitoring (M) | Hourly Basis 1 8. Surface Run Off Water (SRW) Rainy Season 4 Pal CEMC Pvt, Ltd. Page 2 2.0 DETAILS OF MONITORING/SAMPLING STATIONS. To carry out the Environmental Data Generation programme, CEMC in due consultation with OMC has identified different locations to collect the samples for various environmental components in and around the mining lease. The details of stations identified are tabulated below. The locations of monitoring/sampling stations are shown in Plate | & Il. ‘Ambient Air Quality (A) The prime objective of the ambient air quality study is to establish the existing ambient air quality in and around the mining lease area. The existing ambient air quality was monitored at six (6) locations. Monitoring was carried out for Particulate Matter (PMio & PMs) and Gaseous Pollutants (S02, NO; & CO). The monitoring is carried out as per the guideline stipulated by Central Pollution Control Board. Table No. 2.1: Details of AAQ Monitoring Stations Station Details Station Code eee I Longitude | Salandi Bihar A 2a1424"N | a6r19'01.08"E | Mine Office Near Gate-1 | arteogeeN —— g6r19°3456"E | Mine office Near Gate-2 3 21'15'55.98"N 86" 19/36. | BangurVilage AA ES'IB.03"N | "Sankhana Village AS 2I604.0"N Ber 1B4E72"E | Nuarugudl Village ne aaa0738°N 86" 2072898" Work Zone Air Quality (F) To assess the level of fugitive dust due to mining and allied activities, six (6) monitoring stations were selected within the lease considering the activity area. Fugitive emissions monitoring was carried out twice a week on 8 hriy basis. ___ Table No. 2. ls of Fugitive Emission Monitoring Stations | GPS Coordinates Station Detail: Stee — eee boca ae _Aatitude tongitude Near Incline 1 FL 21° 16'04.26"N 86" 19'38.01"E a aad Near ventilation Room (09.00N 86 19'38.94"E Near Time Office 21°16'06.18°N 86" 19'36.96"E Near Stack Yard aeassesrN 86103606" Near Substation 21° 1604.62"N 86° 19'36.12"E | Near weigh Bridge 21° 15'57.09N 86" 19/37.02"E Noise Level (N & WZN) Noise level monitoring was carried out in nearby areas under Ambient Noise Level Survey work as well as work zone area under Work Zone Noise Level survey. Six Ambient Noise Stations have been identified and is carried out for 24 hours on hourly interval once in a month. Three locations have been identified in working area within the mining lease and is measured on hourly interval for 8 hours once in a month. {diel cemceve ua Page 3 Bangur Chromite Mine | sulyzo2s a = zl Table No. 2.3: Details of Noise (Ambient & Work Zone) Monitoring Stations GPS Coordinates, Station Detais Staton Coe 5 aE | mm ‘Ambient Nolse | Pye 21s. nae | 21°16'08.64"N —_—86°19°34.56"E I tes aun Se RS OT SE TE rn |S _ Bangur Vila je N4 21°15'18.03"N 86°19'15.36"E |santhana Vilage SSNS ono |e awaa.73rE ‘Nuarugudi Village NG 21° 16'07.38"N 86° 20'28.98"E z Work Zone Noise 5 Ta NearTime Office wa ar ie061eN | eer i93698 Near Substation WZN2 (or 16'04.62"N. | 86° 19'36.12"E Near weigh Bridge (was 2 ss700"N_86"a9370r'€ ‘Water Quality Surface Water Quality (SW) & Surface Water Flow Measurement (SWFM) In order to assess the quality of surface water, four locations have been identified over Salandi river and Salandi Canal which is flowing on the western side of the mining lease area, The locations have been identified considering the discharge point of mine discharge water. One grab sample was collected from each point in a month and was analyzed various parameters as stipulated in the scope of work. The same locations are identified to measure the flow in the river. Surface Run Off water (SRW) In order to assess the quality of surface runoff water, four locations have been identified within the ‘mining lease through which runoffs gets discharged to the nearby streams/nala. Table No. 2.4: Details of Water Sampling Stations GPS Coordinates | Station Details Station Code = ee ae “Latitude Longitude | c Surface Water Quality/Surface Water Flow Measurement. a | Salandi River swa | 21°14’58.02"N | 86°18°54.00°E th 7 “_Sw2/SWFMA | 21°15'54.48"N86°19'41.76°E | Meeting pt. near U/s of Salandi Canal. SW3/SWFM2__21%14'33.24"N —86°19'01.92"E | Meeting pt. near D/s of Salandi Canal. SW4/SWFM3__21°14'46.08"N___86°19'44.16"E_ 7a Surface Runoff Water | Dump no.2 near maharanala sRWi. 211S'S0.1"N | Be°IS'aaaE Imp no.2 near ome village —srw2211saeN 8619442 imp no.1 near jauthabahali village SRW3 86°19'26.5"E ‘Dump no.1 near road site sRwa 86°19'28.0°E oe CEMC Pvt. Ltd. Page 4 July2023 igur Chromite Mine Meteorology ‘An Automatic Weather Monitoring Station is installed at the rooftop of OMC colony to collect the meteorological data on hourly basis continuously. The parameters recorded at the meteorological station are Temperature, Relative Humidity, Wind Speed, Wind Direction and Rainfall Table No. 2.5: Details of Meteorological Monitoring Stations Station Detail Station Code SPS Soeesintes | |e Pe _ latitude Longitude | Roof top of OMC Colony MM 21°14'47.76" N 86" 19°01.02"E die CEMC Pvt.Ltd. Page 5 E Bangur Chromite Mine | sulyzoza METEOROLOGICAL INITORING REPORT CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 80 9001-2015 & BS OHSAS 45001:2018 Certiied Company, Empanelied with OCCL, ORSAC end SPCB of Govt. of Odisha erected by NABET, QCl for EIA Studies az ‘A’ Category’ Consultant Organization. Empanclled with PCCF(Widife) & CWLW, Odicha Enlisted in Conetruction Industry Development Council (CDC), established by the Planning Commission (Govt. of India) fonment Laborstor/ under Environment (Protection) Act 18 Ref. No. CEMC/OMC/070823/M Date: 07.08.2023 SITE SPECIFIC METEOROLOGICAL DATA © NameoftheIndustries : M/s Odisha Mining Corporation Limited + NameoftheMine, + Bangur Chromite Mine © PeriodofMonitoring July 2023 © Monitored by 'M/sCentre For Envotech and Management ConsultancyPvt.Ltd. © Typeofinstrument _: Automatic Weather Monitoring it eters duly 2023 ‘Maximum 32.08 ‘Temperature (°C) ‘Minimum 24.17 Average 27.23 (Maximum 98.81 Relative Humidity (%) Minienurn 66.56 ‘Average 39.28 ‘Maximum 100 ee ‘Average 27 N 128 NNE on NE 1.87 ENE 201 E 547 ESE 632 se 632 SSE 417 Wind Direction (4) s 733 ssw 6.03 sw 575 > wsw. 6.03 w 216 WNW. 0.00 NW 0.00 NNW oa cAM 44.68 Monthly Total 25 palo No. of rainy days a Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, 4 Safety Studios, [RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mall- ceme_consultaney@yahoo.co.in, ceme122@gmail.com, website: www.cemc.in, Mobile: 8763703371 Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mail: comalab@yahoo.in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 190 900.2015 & BS OHSAS 45001:2018 Certified Company, Empanelled with OCCL, ORSAC and SPCS of Govt of Odisha Accredited by NABET, QCl for EIA Studies as ‘A’ Category Consultant Organization. Empanelled with PCCF(Wiife) & CWLW, Odisha Enlisted in Construction industry Development Council (CIDC), established by the Planing Commission (Govt. of India) MoEFECC, Govt of ina, Recognized Environment Laboratory under Environment (Protection) Act. 186 WINDROSE DIAGRAM ~ July 2023 ‘ype : 24 Hrly; Direction : From) 2 aut 302 Stray Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. ¥ This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Suides, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultancy@yahoo.co.in, cemc122@gmail.com, website: www.cerc.in, Mobile: 8763703371 [Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mat: comelab@yahoo.in, Mobile: 7752014842 ‘Bangur Chromite Mine Ambient Air Quality Monitoring Report bisa CEMC Pvt Lid. Page 9 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 8001-2015 & BS OHSAS 45001:2018 Certiied Company, Empanelled with OCCL, ORSAC and SPCB of Govt of Odi ‘Accredited by NABET, GCI for EIA Studies as ‘A’ Category Consultant Organization. Empanelled with PCCE (Wile) & WLM, Odisha Enlisted in Construction Industry Development Counel (CI0C), established by the Planning Commission (Govt of Indl) MoEFECC, Govt of india, Recognized Environment Laborstory under Environment (Protection) Act, 1996. Ref. No. CEMC/OMC/070823/AAQ Date: 07.08.2023 ANAL 1 [Station Name (Station Code) : Salandi Bihar (A1)] ‘+ Nameofthe industries: M/sOdisha Mining Corporation Limited + NameoftheMine — : Bangur Chromite Mine * Periodof Monitoring: July2023, © Durationofmonitoring : 24hrs + SampleCollectedby —_: M/sCentre For EnvotechandManagement Consultancy Pvt.Ltd. + Typeofsample + Ambient Air Quality sil. | Date PMio (ug/m") PMs SO, NO, co No. (ug/m*) Mugs) (ugh) (mg/m?) 4 | e3072035 48 26 72 125 BDL 2 [oxo72008 ‘Monitoring not done due to rain 3 | to07 2033 4 20 66 104 BOL | Baoraa Monitoring not done due to rain 5 ao7208 2 7 54 10.1 BL 6_| 2007-2073 ‘Monitoring not done due to rain 7_| 2a07.2073 40 5 48 96 BDL | ror aes : hor Monitoring not done due to rain Max 8 26 72 125 BOL Min. 40 15 48 36 BDL ae B50 19.50 6.00 10.65 BDL CPEB Sendard 100ye/m? ‘Oue/m> ‘80 ua/m> 0 ue/ms ‘4me/m> Testing “posi “posi | Mmmegetwet | Mice | Specrwyiso Method (areas) Raan19 (rary Raams — (Setrsenit) "sKa(Part 10) — sSOstE ar RA2v09 ns Ra 2012 Te BI of 50, <8 pal, NOS palm, COD a seb sea Au ratory Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent ofthe laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultaney@yahoo.co.in, cemc122@gmail.com, website: www.ceme.in, Mobile: 8763703371 Laboratory At: Plot No. 80011274, Johal, Pahal, Bhubaneswar-752101, E-malt: cemclab@vanod in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 9001-2015 & BS OHSAS 45001:2018 Certiied Company, Empanelled with OCCL, ORSAC and SPCB of Govt. of Odisha Accredited by NABET, GC! for EIA Studies as A’ Category Consultant Organization. Empanelied with PCCF(Widife) & CWLW, Odisha Enlisted in Construction Industry Development Counel (CIDC}, established bythe Planning Commission (Govt. of Ina) MoEFECC, Govt of india, Recognized Environment Laboratory under Environment (Protection) Act, 1986 Ref. No. CEMC/OMC/070823/AAQ Date: 07.08.2023 ANALYSIS RESULT OF AMBIENT AIR QUALITY [station Name (Station Code) : Mine Office Near Gate-1 (A2)] + Nameoftheindustries : M/s Odisha Mining Corporation Limited ‘+ NameoftheMine —_: Bangur Chromite Mine © Period ofMonitoring — : July2023 + Durationofmonitoring : 24hrs ‘© SampleCollectedby —_: M/sCentre For Envotechand Management Consultancy Pvt. Ltd. ‘© TypectSample : Ambient Air Qu Sl | Date PMio (ug/m") PMs S02 NO, co No. (ues) (ug/m’) (ug/m’) (engi?) a | 3072035 33 34 78 13.2 801 2_[ 06072073 Monitoring not done due to rain 3 [toor 2033 30 30 66 116 BOL 4070 Monitoring not done due to ain 3 [arora 46 7 61 104 coy &_| 2o072023 Monitoring not done due to rain 7 | 24072033 a 2 Sa io BOL &_| 7.072033 as Monitoring not done due to rain ax. 53 34 78 132 Bt Min. a2 2 54 10.1 sou aoe 4775 28.25 648 11.33 ca ‘CPCB Standard 00ug/m> ‘6Oug/m> 80 ye/m> 80 g/m? mg/m? resting “pos “most, | Impetiet | Tr | speemcnisO ‘Method (rare23) RAZ (Pare) Razwiy ai (Sa-Arsenite) ‘S182(Part 10) cn Sosa rar mans oa RA20I2 Ties WO of 50; < Spal, NOR nal, CODA GPT Bieta Authored Signatory Notes: > The results relate only to the sample tested, > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wide Management Plan, Hazardous & Safety Studies, Regd. Office: Plot No-22/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odish: RS & GIS, Baseline Survey, Hydrological & Geologleal Studies, Socio-economic Studies, DGPS & ETS Survey. E-mail- ceme_consultaney@yahoo.co.in, cemct22@gmail.com, website: www.cemc.in, Mobile: 8763703371 Laboratory At: Plot No. 800/274, Johal, Pahal, Bhubaneswar-752101, E-mail: cemetab@yahoo.in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND Ref. No. CEMC/OMC/070823/AAQ Date: 07.08.2023 RESULT OF AMBIENT. JALITY. [Station Name (Station Code) : Mine Office Near Gate-2 (A3)] + Nameoftheindustries = M/sOdisha Mining Corporation Limited * NameoftheMine ——: Bangur Chromite Mine * Period of Monitoring: July2023, * Durationofmonitoring : 24hrs ‘+ SampleCollectedby —_: M/sCentre For EnvotechandManagement Consultancy Pvt. Ltd ‘+ TypeotSample : Ambient Air Quality sl | Date PM (na/m") PMs SOp NO, co No. (ug/m' (ug/m") (ugh) (mg/m) a | 04072038 38 38 83 139 ot 2 | enor 20% ‘Monitoring not done due to rain 3 | tr072038 32 33 76 24 80 &_ | aao7 20% 47 28 61 12 co 5 | as072035 45 25 57. 105 Bt | 2072073 3 | sora Monitoring not done due train 3 | aor aR Max. 58 38 83 139 cy Min. 45 25 57 105 cy co 50.50 31.00 6.93 12.00 Bot PCR Standard 100ua/m? ‘oug/m? 20 peso 0 pe/m? 4 me/m3 i Gravee ‘Gravimetric ‘Moifed Tacob & Nie Testing 1s0siK Tsosis2 sapeaned Wet “ochhcier SpecreconytSO Method (rare) RA2019 (eareag mans oa (Ss-Arseite) ‘1sz(Part 10) se T5051 art prety ° (area) RA2017 Arey ‘Wote BOI of 50; <4 nal NOS pale, COBH maT Bion Au Signatory Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent ofthe laboratory. > ‘The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent ofthe laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultancy@yahoo.co.in, ceme122@gmail.com, website: wwrw.cemc.in, Mobile: 8763703371, Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mall: cemetab@yahoo.In, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 9001-2015 & BS OHSAS 45001-2018 Certified Company, Empanelled with OCCL, ORSAC and SPCB of Govt. of Odisha ‘Acetedited by NABET, CCI for EIA Stdles ae ‘A’ Category Consultant Organization. Empanelled wth PCC (Wdlfe)& CWLW, Odisha Enlisted in Construction industry Development Counel(CI0C). established by the Planning Commission (Govt of India) MoEFACC, Govt. of inda, Recognized Environment Laboratory under Environment (Protection) Act, 1986, Ref. No. CEIMC/OMC/070823/AAQ_ Date: 07.08.2023 ANALYSIS RESULT OF AMBIENT AIR QUALITY [station Name (Station Code) : Bangur Village (A4)] '* Nameoftheindustries : M/s Odisha Mining Corporation Limited. * NameoftheMine —: Bangur Chromite Mine © Period of Monitoring: July2023 ‘© Durationof monitoring: 24hrs ‘© SampleCollectedby —_: M/sCentre For Envotechand Management Consultancy Pvt. Ltd + Typeofsample : Ambient Air Quality si. Date PMc (Hg/m*) PMs, ‘$0; NO, co No. (ughm*) (ug/m*) (ug/mn*) {mg/m’) 1 | oan720%8 46 26 68 116 BL 2_[ o70720%8 Monitoring not done du to rain 3 [| auorze aL 23 Sa 105 BOL | e072023 38 20 Sa. 97, BOL 5 [ seo720%8 35 18 44 93 BOL &_[ aaora0m 7) a7 Monitoring nat done de to rain | peor 20% Max. 46 26 68 116 Bot Min. 35 18 44 33 Bot ae 40.00 2175 5.43 10.28 Bot (PCB Standerd 100y¢/m3 0ug/n> 80 g/m? 80 ug/m? Amgsm? Testing “goun Sean | tewetwet | nme” | aeceeto Method (rarezy Rains | Parez Razoiy | maGeake (Xs-Arseite) "iea(rar 10) =. 150m ar RA2009 Cor) pater ‘Woe: BOL of 50; <4 pal NOx wale? COOL male Le AuthortZed Signatory Ssakat { Laboratory Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent ofthe laboratory. The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (IA & EMP), Monitoring, Forest Diversion Planning, DPR. Wildlife Management Plan, Hazardous & Safety Studies, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, 'E-mail- ceme_consultancy@yahoo.co.in, cemc122@gmail.com, website: www.cemc in, Mobile: 8763703371 Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mall: cemelab@ivahoo In, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 800) Ref. No. CEMC/OMC/070823/AAQ Date: 07.08.2023 ANALYSIS RESULT OF AMBIENT AIR QUALITY [Station Name (Station Code) : Sankhana Village (A5)] * Nameofthe industries |: M/sOdisha Mining Corporation Limited © Nameofthe Mine +: Bangur Chromite Mine * Period of Monitoring * Durationofmonitoring : © SampleCollected by M/s Centre For Envotechand Management Consultancy Pvt. Ltd. © TypeotSample + Ambient AirQualty ‘Sh. Date PM (ug/m*) PMs ‘SO, NO, co No. (ugh) (ugh?) (ug/m’) (omg/e) Fa EE Tontorng not done due or 2. | 05.07.2023 44 24 66 10.9 BOL 3 on araon Taonga done oe a [ara m7 7 Sa 7 wo 5 [isera0 «| apara0n itoring not dane due ton 7] mara a wears 9, | 29.07.2023 32 1s 42 91 Bot Max, 44 24 66 10.9 C3 _, 32 15 42 91 oo Avg. 38.67 18.67 5.30 9.90 oo oan 100ug/m3 6Oug/m> (80 yg/m> ‘80 ye/m? 4mg/m? Testing “pos Spot | imegetwet | Miter | spamuontsO Method | qanrynams | earagnams | mmacaie | tne | Shennan osm | SOS Ow. wae cm, neta a BO FE RO pal OAT Sa Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai,Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultaney@yahoo.co.in, cemct22@gmail.com, website: www.cemc in, Mobile: 8763703371 Laboratory At: Pot No. 80011274, Johal, Pahl, Bhubaneswar-752101, E-mail: cemctab@yahoo.in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 80 8001-2015 & BS OHSAS 45001:2018 Certiied Company, Empanelied with OCCL, ORSAC and SPCB of Govt. of Odisha ‘Accredited by NABET, OCI for EIA Studies as ‘A’ Category Consultant Organization. Empaneled with PCCF(Widlife) & WLM, Odiha (i Enlisted in Construction Industry Development Counell(CIDC), established by the Planning Commission (Govt. of india) k ‘MoEFECC, Gov of nda, Recognized Environment Laborstery under Environment Proteton) Ac, 1988 Ref. No. CEMC/OMC/070823/AAQ. Date: 07.08.2023 ANALYSIS RESULT OF AMBIENT AIR QUALITY [station Name (Station Code) : Nuarugudi Village (A6)] ‘+ Nameoftheindustries |: M/s Odisha Mining Corporation Limited + Nameofthe Mine Bangur Chromite Mine '* Period ofMonitoring — : July2023 © Durationofmonitoring : 24hrs ‘+ SampleCollectedby —_: M/sCentre For EnvotechandManagement Consultancy Pvt. Ltd. © TypeotSample + Ambient Air Quality s_| Date Mio (ue/m") PMs ‘SO; NO, co No. (ue/m*) (ug/en’) (ughen’) (mg/mn*) i_| on072073 ‘onioring not done de to rain 2_| 05072033 % 7 63 4 80L 3 | enor aan onitoring not done dos ta ain a [aor 37 20 54 35, BOL 5 [ 07203 | s.07203%3 Monitoring nat done due to rain 7_[ 2.072033 &_ | 36072035 3. | 23072023 35 B a7 33 Bot Max. 46 27 69 14 ot Min. 35 13 47 33, Bot ae 39.33 20.00 5.67 10.07 cy CPC Standard 100ue/m> ‘6Oug/m? 80 g/m? ‘80 ue/m? 4ma/m? Gravimee Granimerne Mosiied Tab NDI Testing wsosie2 150 S142 —— “echlcser Spectrscopy1SO Method (wares) A209 (rarena) A209 (Streit) ‘ix2(Part 10) —— SOIR ar anos ‘are Ra 017 La ‘Note: BDL af $0, <4 pa/n?, NOx<9 g/m, COXD.11 mg/m? — eRe Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazerdous & Safety Studies, 'RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458 Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultancy@yahoo.co.in, ceme122@gmail.com, website: www.cemc.in, Mobile: 8763703371 Laboratory At: Pot No. 800/1274, Joha, Pehal, Bhubaneswar-752101, E-malt comelab@yahoo in, Mobile: 7752014842 | | suly 2023 = = I Bangur Chromite Mine Annexure -3 Fug Emission Monitoring Report Page 16 Pal MC Put Lid Govt. of India, Reet lustry Development Counc (C10), established bythe Planning Commission (Govt. of na Environment Laboratory under Environment (Protection) Act 1986. Ref. No. CEMC/OMC/070823/FE ANALYSIS RESULT OF FUGITIVE EMISSION Name ofthe industries : M/s Odisha Mining Corporation Limited Date: 07.08,2023 *® Nameofthe Mine + Bangur Chromite Mine * PeriodofMonitoring :July2023 + Durationofmonitoring Bhs * Sample Collectedby M/sCentre For Envotech and Management ‘Consultancy Pvt. Ltd. * Tyrsotsimde + Fugitive Emission Near Incline-1 (F1) ‘Near Ventilation room (F2) S.No. | date of Monitoring Total Suspended Particulate ‘atter(TsPMresult in (ug/m*) z 03.07.2033, 265 382 2 (06.07.2023 ‘Monitoring not done due to rain ‘Monitoring not done due to rain 3. 10.07.2023 210 233, 4 13.07.2023 Monitoring not done due to rain Monitoring not done due to rain 5 17.07.2083 196 254 6 20.07.2023, Menioring not done due to rain | ~ Monitoring not done due torn 7 24.07.2023, 183 225 8. 27.07.2023 Monitoring not done due to rain Monitoring not done due to rain 9. 31.07.2023 Monitoring not done due to rain ‘Monitoring not done due to rain Max. 265 282 Min. 18 325 ‘Ave. 475 248.50 CPCB Standard 1200 pg/m* Testing Method Gravimetric Method P,P pot antithet any Notes: > The results relate only to the sample tested. v This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. ‘? consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, RS & GIS, Baseline Survey, Hydrological Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Colla, E-mail- ceme_consultancy@yahoo.co.in, ceme122@gmail.com, website: www. ‘This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written ‘Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, & Geological Studies, Socto-economic Studies, DGPS & ETS Survey. ahal, Bhubaneswar-752101, Odisha, .ceme.in, Mobile: 8763703371 Laboratory At: Plot No. 800/1274, Johal, Pahl, Bhubaneswar-752101, E-mail: cemdab@yahoo.in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 900.2015 & BS OHSAS 45001:2018 Certiled Company, Empanclied wth OCCL, ORSAC and SPCS of Gov. of Odishe EMC Accredited by NABET, GCI for EIA Studies a5 A’ Category Consultant Organization. Empanelied with PCCF (Wilds) & CWLW, Odishe Enlisted in Construction industry Development Covel (CIDC),extabllaned by the Planning Commission (Govt of Ila) Ref. No. CEMC/OMC/070823/FE Date: 07.08.2023 ANALY ULT OF FUGITIVE EMISSION ‘+ Nameofthe industries: M/s Odisha Mining Corporation Limited © NameoftheMine —: Bangur Chromite Mine © Period of Monitoring: July2023 + Durationofmonitoring : &hrs + SampleCollectedby —_: M/sCentre ForEnvotechandManagement Consultancy Pvt Ltd + TypeofSample + Fugitive Emission "Near Time Office (F3) "Near Stack Yard (F4) S.No, | detwof Monitoring Total Suspended Parisite Mater SPHresul in (ug/m) i (04.07.2023 302 324 2. (07.07.2023 Monitoring not done due to rain | Monitoring not done due to rain, 3. 11.07.2023 255. 231 4. 14.07.2023 216 210 5. 18.07.2023 247 249) 6. 21.07.2023 ‘Monitoring not done due to rain | Monitoring not done due to rain 7. 25.07.2023 Monitoring not done due to rain | Monitoring not done due to rain 8. 28.07.2023 ‘Monitoring not done due to rain | Monitoring not done due to rain Max. 302 324 Min. 216 210 ‘Ave. 255.00 253.50 PCB Standard 1200 ng/m™ Testing Method Gravimetric Method pers Authorized Signatory Notes: > The results relate only to the sample tested, ‘This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. ‘The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise. v * ‘This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Widife Management Plan, Hazardous & Safety Studies, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, OGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultancy@yahoo.co.in, comet22@gmail.com, website: www.cemc.in, Mobile: 8763703371 Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mail: cemelab@vahoo.in, Mobile: 7752014842 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 900.2015 & BS OHSAS 45001:2018 Certified Company, Empanelled with OCCL, ORSAC and SPCB of Govt. of Ouisha EMC Accredited by NABET, OC for EIA Studies as ‘A’ Category Consultant Organization. Empanelled with PCCF(Wlaife) & CWLW, Odisha e ‘Construction industry Development Counel (CIOC), established by the Planning Commission (Govt. of nc Govt of india Recognized Environment Laboratory under Environment (Protection) Act. 1988. Ref. No. CEMC/OMC/070823/FE Date: 07.08.2023 ANALYSIS RESULT OF Fi Nameofthe industries: M/s Odisha Mining Corporation Limited * NameoftheMine —_: Bangur Chromite Mine ‘+ Periodof Monitoring — : July2023 ‘© Duration ofmonitoring : 8hrs + SampleCollectedby —_: M/sCentre For nvotechandManagement ConsultancyPvt. Ltd. ‘© TypeofSample + Fugitive Emission "Near Substation (F5) ‘Near Weighbridge (F6) Sl.No. | date of Monitoring Total Suspended Particulate Matter TsPoapresit | in (ug/m’) 2 (01.07.2023 Monitoring not done due to rain | Monitoring not done due to rain 2. (05.07.2023 266, 325 3. (08.07.2023 ‘Monitoring not done due to rain | Monitoring not done due to rain 4. 12.07.2023 211 27 5. 15.07.2023 ‘Monitoring not done due to rain | __ Monitoring not done due to rain 6. 19.07.2023 ‘Monitoring not done due to rain | _ Monitoring not done due to rain 7. 22.07.2023 ‘Monitoring not done due to rain | _ Monitoring not done due to rain a 26.07.2023 ‘Monitoring not done due to rain | Monitoring not done due to rain 3. 29.07.2023 172 203 Max. 266 325 Min. 172 203 ‘Avg. 216.33 266.33 (CPCB Standard 1200 ne/m Testing Method Gravimetric Method aaa Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise, > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economle Studies, DGPS & ETS Survey. Regd. Office: Plot No-522/3458,Near Utkal Hyundai, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultaney@yahoo.co.in, cemet22@gmail.com, website: www.cemc.in, Mobile: 8763703371 Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101, E-mail: cemclab@wyahoo in, Mobile: 7752014842 | GME sancur chromite mine suly2023 Ambi e Monitoring Report CEMC Pvt Lid Page 20) CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 9001-2015 & BS OHSAS 45001:2018 Certified Company, Empanclied with OCCL, ORSAC and SPCB of Govt. of Odisha ‘Accredited by NABET, OCI for EIA Stucies as ‘A’ Category Consultant Organization. Empaneled with PCCF (Wildlife) & CWLW, Odea Enlisted in Construction ndutry Development Council (C106), established by the Planning Commission (Govt o India) MoEFSCC, Govt of india, Recognized Environment Laboratory under Environment (Protection) Act, 1986. Ref. No. CEMC/OMC/070823/NL Date: 07.08.2023 ANALYSIS RESULT OF AMBIENT NOISE LEVEL = Nameofthe Industries: M/s Odisha Mining Corporation Limited + NameoftheMine _: Bangur Chromite Mine * Periodof Monitoring: July 2023, © Durationofmonitoring : 24hrs * SampleCollectedby —_: M/sCentreFor Envotech and Management Consultancy Pvt. td. + Typeofsample Ambient Noise Night Time station name | Sion] Dateot| PayTimei96:00 | ant oci00 | category of Area Code | Monitoring} Hrs) max | min | avg* | max | min | avg* Salandi Bihar ni_ [17.07.2023 | 50.9 | 31.2 | 44.3 | 332 | Bot | 30.8 | Commercial [Mine Office Near Gate-1|N2__|18.07.2023 | 57.1 [ 319 | 49.7| 34.8 | BOL | 31.4| Industrial [Mine Office NearGate-2[N3__ [19.07.2023 | sa.9 | 32.3 | 51.1 | 35.1 | pot | 315 Industrial Bangur Village na [20.07.2023 [48.7 | 31.6 | 422 | 343 | BDL | 314| Residential [Sankhana Village ns [21.07.2023 [46.8 | 31.3 | 40.4 | 34.2| eo. | 31.1] Residential Nuarugudi Village né__ [22.07.2023 [49.1 | 31.6 | 420 | 336 | BOL | 309| Residential AMBIENT NOISE STANDARDS Day Timefas (ay | Night Time(es ay) Industral 75 70 Commercial 65 55 Residential 55 45 Sensitive 50 40 “Laparithnic Averages, BDL Lit The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified otherwise, » This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wildife Management Plan, Hazardous & Safety Studios, RS & GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economle Studies, DGPS & ETS Survey Regd. Office: Plot No-522/3458,Near Utkal Hyundal, Opposite APEX Collage,Pahal, Bhubaneswar-752101, Odisha, E-mail- ceme_consultancy@yahoo.co.in, cemet22@gmail.com, website: www.ceme in, Mobile: 8763703371 Laboratory At: Plot No, 800/1274, Johal, Pahl, Bhubaneswar-752101, E-mail: comclabé@vahoo.in, Mobile: 7752014842 | July 2023 GHME sangur chromite Mine Annexure -5 Work Zone Noise Monitoring Report Page 22 CEMC Pvt Lid CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An 180 8001-2075 , OHSAS 18001-2007 & $0 14001-2015 Certified Company, Empanelled with OCCL, ORSAC and SPCB of Govt. of - Odishe Accredited by NABET, QCl for EIA Studies as 'A° Category Consultant Organization. Empanelieg with PCCF Wife) & pcemd CWLW,Odish, Enlisted in Construction Industry Development Council (CIDC) established by the Planning Commission (GovL. of nda), x NABL Cortifed NoEF&CC, Gov of indi, Recognised Environment Laboratory under Environment (Protection) Act, 18. Ref. No. CEMC/OMC/070823/WZN Date: 07.08.2023 ANALYSIS RESULT OF WORK ZONE NOISE LEVEL ‘M/s Odisha Mining Corporation Limited Name ofthe Mine Bangur Chromite Mine PeriodofMonitoring — : July 2023 + Name ofthe Indust * Durationof monitoring : Bhrs SampleCollectedby —_: M/sCentreFor Envotech and Management Consultancy Pvt. Ltd. Type of ample : WorkZone Noise a ‘Station | Date of ‘Measurement ‘OHSAS No, | _ Station Name Code _| Monitoring ‘Values Standard 1._| NearTime Office | W2Ni (03.07.2023 456-632 2.__| Near Substation | WZN2 (04.07.2023 524-684 90 ‘Near Weighbridge | WZN3 05.07.2023 55.2706 Valeri dB Ae Notes: > The results relate only to the sample tested. > This Test Report shall not be reproduced wholly or in part without prior written consent of the laboratory. > The samples received shall be destroyed after two weeks from the date of issue of the Test Report unless specified A otherwise. > This Test Report shall not be used in any advertising media or as evidence in the court of Law without prior written consent of the laboratory. Environmental Studies (EIA & EMP), Monitoring, Forest Diversion Planning, DPR, Wikiife Management Plan, Hazardous & Safety Studies, ‘RS £ GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studles, DGPS & ETS Surve) Regd. Office: 1" Floor, N-5/305, IRC village, Nayapalli, Bhubaneswar-751015, Odisha, India, Mobile: 9861032826 E-mail- cemc_consultaney@yahoo.co.in, ceme122@gmall.com, website: www.cemc.in, Landline: 0674-2360344. Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-75210', E-mal: comdabi@yahoo.in, Mobile: 9937631956, 889517314 GAME "neue chromite mine July 2023 Annexure -6 Results of Surface Water Analysis Page 24 CENTRE FOR ENVOTECH AND MANAGEMENT CONSULTANCY PVT. LTD. ‘An $0 900.2015, OHSAS 18001:2007 & ISO 14001-2015 Cortifed Company, Empenelled with OCCL, ORSAC and SPCB of Govt. of Osisha Accredited by NABET, QCi for EIA Studies as A’ Catogary Concultant Organization. Empanlied with PCCF (Wife) & EMC. CWLM.Odisha, Enlisted in Construction Industry Development Council (CIDC) established by the Planning Commission (Govt. of Indi), NABL Geriied MoEF&CC, Govt af Indl, Recognised Environment Laboratory under Environment (Protection) Ack 1886, Ref. No. CEMC/OMC/070823/SW Date: 07.08.2023 ANALYSIS RESULT OF SERFACE WATER + Nameoftheindustries _ : M/s Odisha Mining Corporation Limited © NameoftheMine ——: Bangur Chromite Mine © Period ofMonitoring — : July 2023, + Date of sampling 12.07.2023 + Date of Analysis 13.07.2023 to 25.07.2023 * SampleCollectedby _: M/sCentreForEnvotechand Management Consultancy Pvt.Ltd. + TypeofSample Surface Water [ Salandi River{ SW1)] [U/G Mine Discharge Water (SW2] (Meeting pt.near U/s of Salandi Canal.(SW3)][Meeting pt.near D/s of Satandi Canal(sW/4)] Parameters Unit Testing Methods swi sw2 sw3 swa Tolar | s s s s Odour Unobjectionable | Tella et w/o w/o w/o ujo aoe meh | amas eamir ssw 2 a = = “Turiity NTU __| hgh 9 is a 2 Pivaloe = ANS aor eae a2 750 7:36 752 Temperature % a cop 7 19 16 2 Ta Grease Tel | ramevieneo s s s s (te reocin) sonar 200 "Ammorieal ah Dion Faved ry 288 258 Baa 2 ritrogen(as NI aruassta 2 ant Total Ki: Nirogenfas ra orarrpaale 36 24 38 26 NH) AMAT 0-00 Nao Total ardness as me Era mca Mee @ Cc 56 B on ARAB EasorY ene iron os) | 030 026 022 028 ‘chloride fase mah | tet acre 8 2 4 38 orde (as Dottie eee =| Forde ser met 7 056 032 62 038 i APA" 2017-40 Total Disoved Side | meh | Grima Mee 18 iz 134 146 ‘alcom Tas Ca) a 312 276 332 318 ‘Magnesium (as Mi mel | ae ven 106 92 4 38 Copperas Cu) ret | a ve

You might also like