Installation Guidelines

1 .5 m m Ca b le D isp la y Systems 800.753.9688 www.novadisplay.com

Concrete Wood Lathe & Plaster Plasterboard Suspended Ceiling


Ceiling beams
Toggle Bolt
Plumb-line

Battening
Rawlplug
Plumb-line

1 2 3 4 5

*** DO NOT INSTALL INTO PLASTERBOARD (DRYWALL) CEILINGS OR WALLS


IF YOUR APPLICATION INCLUDES GLASS SHELVING OR OTHER HEAVY ITEMS.

Top to Bottom (C101-4/C201-4)


Cable Installation
A

IMPORTANT: It is essential to check that the top ceiling


B fixings are strong enough to take the weight of the items being
displayed, while allowing for the tension in the cables.

CB-ST (Page #1) 1) Affix fitting (A) to ceiling:


Standard Base Support - for wooden ceilings use a wood screw.
- for cavity ceilings use a spring toggle bolt.
Die-cast Cable - for solid ceilings use a rawl plug and screw.
Crimping
2) Screw fitting (B) to fitting (A).
CF-T (Page #7)
Ceiling Coupling Cap 3) Using a plumb-line, descend from (A), and fix (F) to floor
using appropriate type of fixing.
4) Loosen the grub screws in fitting (E), using the Allen key
provided, and slide fittings (C), (D), and (E) up the cable.
5) Pull down and cut off excess cable as per diagram below.
6) Tighten (E) on the end of the cable.
2 mm Cable 7) Adjust the tension of the cable by screwing (C) into (F).
(Stainless Steel or Galvanized)
NOTE: It is important to check the strength of the top fixing. NOVA
DISPLAY® takes no responsibility for incorrect installation. This
responsibility rests with the installer.
CF-B (Page #8)
Floor Coupling Cap Cables are not supplied with fixing screws.

Compression Spring

PCP-02 (Page #11)


Cable Crimping
CB-ST (Page #1) C
Standard Base Support

F CUT
LINE

Expanded View Sectional View