You are on page 1of 25
Catalogue 2.1 Localization- 2.2 Circular telegram and start. 3 Technical parameters- 3.1 Working condition— 3.2 Performance. 3.8 DISPLAY 4 Operations. 41 Starts to operate, main menu 4.2TE 4.3 Test Proces: 4.3.1 Insert distilled water- 4.3.3 Blank. 4.3.4 Standard- 4.4.3Time printing 6 PROGRAMMING---- 6.1Create New ‘Test-- 6.2Pump Parameter-- 6.3 Restore Parameter- 7 MAINTENANCE’ 7.1 General standard—~ 7.2 Suckers Service- 8 APPENDIXES AND REPLACEMEN’ 9 TROUBLES AND SOLUTION-- Installation Diagram 1 Introduction This instrument is a semi-auto biochemistry photometer, especially suitable for using in the clinical laboratory. | can does many complex works, makes the operation extremely simple through menu system and interface, so makes between the user and the instrument establishes the extremely harmonious relations. This instrument except provides the very strong reliability in optics, but also provides to the many kinds of measuring tool compatibility, such as Peristaltic system with flow cuvette, 18uL that thermostatization by Peltier system (23-40°C). PCcommunication software allowed more than 21 different determinations group examines parameter And it can save more than 100 different tests, ‘The photometer functionality is completely completed by a series of automatic computations methods that are decided by the selected biochemistry analysis method—End Point, Both Point Mode, Fixed Time and Delta Kinetics, for example 2 Installation In order to make the operation of the photometer reach to the best state, please install it according to the explanation of this chapter. 2.1 Localization The photometer is installed in the dry and non- corrosion environment. Moreover, cannot be approached to the electromagnetism radiant (for example, the motor and the centrifuge), heat source as well as direct absorption glare and sunlight places. It must be put on the roomy and firm platform, take care not have any goods block the fan, or affect the air circulation. Be left the recent wall at least 15cm The waste liquid bottle should be laid at the same high or lower than the photometer. 2.2 Circular telegram and start In this moment we will watch the state of the connection power source, and do some simple inspections. 2.2.1 Power source quality |tis very important that the photometer joins with a good electric system. Using special power source as far as possible, and the power source must have the GND port, If the photometer works abnormal (such as the program not work, the photometer reset occasionally and 's0 on), should check it whether approaches the centrifuge either the machine with motor or electro-magnet that can produce the strong electricity noise. At this kind of situation, the biochemistry photometer should be far away from the equipment. The voltage category is I! 2.2.2 Check voltage ‘The electric current that the photometer used is AC220V#10% 50Hz/60H2. Notices, the photometer works at the limit current will cause not working so as to be destroyed. When the power source does not conform to the instrument request, should be replaced or install the voltage regulator. 2.2.3 Connect with power source If the photometer voltage and power source is match, carries on according to the following step, First, Check the switch is whether on the closes (0) position Second, Connect the power cable, connect the photometer first, and then connect the power source. Third, Open the switch to (1) position. 3 Technical Parameters 3.1 Working conditions 3.1.1 Ambient temperature from 10°C to 30°C 3.1.2 Relative humidity less than 80% 3.1.3 Far away from the strong electromagnetic and noise 3.1.4 AC 220V-+22V S0Hz+ 1Hz 3.1.5 Avoiding the glare or the sunlight direct radiation 3.1.6 Good GND port 3.2 Performance 3.2.1 Reading filter correctness is £5 nm 3.2.2 Errors Analysis Method Range of ABS (A) Error % End Point Differential Mod 02-03 5 Delta Kineties $303 —_}___= Both Point. — |——— — _— >1.0—2.2 3.2.3 Absorbance Duplication Absorbance Duplication <=0.005 (A) 3.24 Stability 3.2.4.1 In 20 min, Change of the Absorbance<= 0.01 (A), 3.2.42 In 1 h, Change of the Absorbance<= 0.01 (A) 3.3 Temperature The cuvette permanent temperature is 25 C, 30 C and 37 C, temperature correctness is 40.5 and the range of temperature change is from -0.4°C to +04. 3.4 Carry over Flow cuvette carry over percentage <= 2% 3.5 Cuvette Peristatic system with flow cuvette, 18uL. 3.6 Sipping system ‘The flow system of peristaltic pumps which in the cabinet, Pump drove by Low voltage motor. Sipping volume can be setting from 800u! to S889ul Peristaltic system with flow cuvette, 18Ul, ‘Sample volume automatic calibrate, sample position automatic calibrate In order to assure the accurate test, suggest the sample volume is more than 800ul HWSPABC HOUND, MODE: Fp With Stan READING FILTER. Sitinm TEMPERATURE: 37(C FACTOR. STANDARD: UNITS: mmol INCUBATION TIME INTERVAL TIME SIPPING VOLUME Press ENTER to modify the READING FILTER Previous Nest Press ENTER, with CUTDOT UP, DOWN key to choice the required temperature, for exampie 25 ( press ENTER to enter the next item, IeSPABC ROUND.0-10) MODE: Eaupoin With Standunt READING FILTE:.$10nm TEMPERATURE 25 EACTOR. STANDARD: UNITS: mmol INCUBATION TINE INTERVAL (IME SIPPING VOLUME Press ENTFR to mociy the READING FILTER Previous Next Press ENTER to contirm modify the factor, press number keyboard to input parameter, for example 20, press C to delete the parameter, and press +/- corresponds A key to edit the positive factor and negative factor, then press ENTER to enter the next item; HSTABC ROLUND.0-10 MODE: Fingpoioe With Stand READING HLITR: $10nm ILMPERATURE: 37 FACTOR. STANDARD: UNITS: mmol INCUBATION TIM INTERVAL TIME SIPPING VOLUSH Press ENTER (0 modi the READING FILTER Previous Next Press ENTER to confirm modify the standard, press number keyboard to input parameter, for example 5, press C to delete the parameter, then press ENTER to enter the next item: HWSEABC BOUND. MODE: Endpoint With Standard READING FILTER, Stn TEMPERATURE. 37% FACTOR: 20 STANDARD: 5 UNITS. nmol INCUBATION TINH INTERVAL TIME SIPPING VOLUME Dress ENTER we mods dhe UNITS Previous Press ENTER to confirm modify the units, press CUTDOT Up or DOWN key to choice the units for example U/L, the units include, © mmol @ mgidt. @gt Ou © umoti © nkate © ukavl © gidt Press ENTER to enter the next item, TESEABC, ROUIND=0-10 MODI: ndpint With Stas READING FILTER, $10nm TEMPERALURE: 37 FACTOR: 20 STANDARD: 5 UNE Ut INCUBATION TIME INTERVAL LIME SIPPING VOLUME Press ENTER to modi INCUBATION HIME Previous Next Press ENTER to confirm modify the delay time, press number keyboard to input parameter, for example 16, press C to delete the parameter, then press ENTER to enter the next item Notes: the incubation time of the end point mode and differential Mode is stabil time, and the interval time of them is zero. TESEABC BOLIND:G-10 MODE: Endpoint With Standard READING FILTER: Winn TEMPERATURE: 37 FACTOR. 20 STANDARD: S UNITS: UL INCUBATION HIME: 15 INTERVAL TIME SIPPING VOLUME Pross ENTER to modify INTERVAL TIM Previous Next Press ENTER to confirm the test time, press number keyboard to input parameter, for example 0, press C to delete the parameter, then press ENTER to enter the next item

You might also like