U212EN.DOC 17.01.06
1.1 Connections If shaft driven pumps (types RHP or HP) are used
they must be primed according to instruction 10602
Hoses are fitted with BSP -hydraulic connections. For
(SHP) or L3206 (HP, RHP).
process instrument connections refer to instruction
U213.
2.2 Cold start
1.2 Instruments To prevent cavitation and overloading of the pump the
viscosity of the oil at starting temperature should be
The instruments (pressure switch) are recommended to
< 2000 cSt.
be connected according to the N.C. (Normally Closed)
If the viscosity of chosen oil exceeds the allowed a
principle, that in case of wire damage a failure
thinner oil type can be selected on a case by case
message can be received.
basis. (Please contact Moventas Oy.) If the oil type
cannot be changed these are the alternatives:
2. Operating
• a different oil type can be selected for winter and
2.1 Preparing to start-up summer conditions or
Before start-up the following checks must be
completed: • an oil heater can be used (see section 2.3) or
• check the rotation direction of the of the oil pump • synthetic polyalphaolefin (PAO) based oil can be
(the right rotating direction is marked with an arrow) used.
• check all electrical protection devices and lockout
procedures for the possible instruments, as well as When the starting temperature drops temporarily,
the lock out procedures for the driving motor of the (e.g., at a downtime) difficulties in the starting of
gear unit. pressure lubricated gear units can be alleviated by
allowing the electric motor on the pump to run during
Start up is the critical moment for lubrication. It is the downtime.
important to monitor the operation of the pressure
lubrication system. If the system includes a by-pass valve, it automatically
opens on start up with cold oil; when the oil pressure
Always ensure the oil pump sucks oil and exceeds the set point. The valve will automatically
generates pressure to the system. close when the running temperature becomes steady.
Moventas Oy recommends first connecting the electric After start up the gear unit warms up quickly, the
motor for the pump, so that it starts up before the main maximum pressure valve closes and flow passes the
motor of the gear unit. It is also recommended to filter and cooler normally.
protect the oil pumps motor with a current relay.
Moventas Oy 1(2)
Pressure lubrication unit without cooler
U212EN.DOC 17.01.06
Moventas Oy 2(2)