You are on page 1of 1

A B B' B'' C D

0.03
0.43
A B C D A B C D
8.51 8.66 8.94

0.42 0.50 1.20 1.20 0.80


3.32 1.74 3.32 2.20 3.42 3.32 2.20 3.42
5 c-a T/PA T/PA c-a c-a S(x) c-a c-a c-c 5 5 c-a S(b) 2S3(a,x) c-a c-a 5 5 c-a T/PA c-a c-a 5
C1 C1 C1 C1 C1

c-e
C1

c-e
0.73 0.73 A A A T S(x) X

c-a

c-a

c-a
B T 0.54
0.70 S(a) S(a) 0.75
0.56 X X A
0.10 0.10
A A A 0.61 V 0.90 V-A 2.10
1.55 1.95 1.56 1.96 1.55 0.40

2.15 2.12 2.15 2.12 2.15 2.15


0.70 0.71 0.71 A A 1.10
1.20 0.76
1.21 1.27 1.69 0.97
c-a T/PA c-a 4' Y
0.50 0.50 A A
X
S(x) B V 1.00 V 1.00 V-A 2.10 V 1.00 V 1.00
X

c-a
c-a

c-a

c-a
1.68 1.66 1.80 0.20 1.80 0.80 0.40 1.66 1.80 0.20 1.80

c-k
c-k
0.10
4 40.03 4 4
0.03 4 0.73 4

c-b
c-a c-a c-a c-a

c-b

c-b

c-b
c-b
C2 C2 C1 0.33 C2 T
C2 C1 C2 c-a 2S(x,y) C2 T
C1
0.16

2S(a,b)
c-a

c-a

c-a
A A 0.38 S(a)

c-a

c-a
2S(a,b)

c-a
0.86 0.23 0.43
A
B 0.25 A A 0.13 0.37
0.39 A A 0.75

c-a
X

2S(a,b)
T 1.05
0.99 T 0.86 A
0.69 2.20 0.92 1.41 0.35 B B 0.34 B
A A 0.43 0.43 T/PA
0.76 0.49
2S (a,x)

c-a
1.20 3 A
1.50 0.95 T/PA

c-a
A
c-a c-a c-a 1.20 2S(a,b)
c-a T

C1
C2
C3
C4

C2
C3
C4
c-a

C1
X T T/PA
Y S(x) T
2.65 2.65 2.65 S(a)
0.84 0.84 0.60 0.60 2.65 2.65 2.65
1.12 B 1.72 0.48 TG-02 0.51
A 0.70 0.45
A
0.60 0.67 TG-03 1.51 1.51
T/PA T A 1.22 0.55 A
A T
A A
T
1.75 Y T 1.05
Y 0.10 T X

0.88 0.85 A A S(x) Y S(a)


1.70 2S3(a,x) S(y) 2S3(a,x)

2S(a,b)

2S(a,b)
2S (x,y) 0.93 2S (a,b)
1.87
B B X 3 3
0.40 0.77

c-e

c-e
0.35 S3(x)

c-a
c-a

c-a

c-a

c-a

c-a
c-a
X 0.22 2S3(a,b) T
X T/PA
0.97
T 2S(x,y) 1.20 1.63

C2
C1
C3
C4
C5
c-b

c-b
3 3 3 3 3 3

c-a
C1 c-a S(x) C1 C1 0.33 C1 0.70 0.70 C1 c-a C1 C1 C1 C1
1.30 0.80 c-a X 2.00
0.20
0.44 1.53 0.85

c-a

c-a
c-a

c-a

c-a

c-a

c-a

c-a
0.50 0.75x2.10m TG-01 T 1.07
Y T Y B Y
0.62 A T 0.63 0.66
A A S(x) T X A A
0.93 2S(a,b)

c-a
T

2S(x,y)
11.40 X
0.72 11.40 11.40 0.91 11.40 11.40 X 11.40
1.63 0.73 0.73 X 0.60 1.82 0.60
c-a
B 2S(a,b) A A S(y)
A A

c-a
1.70 A
c-a T/PA 0.91
T S(x) 2S (a,b)
B 3
0.37 0.45 1.63
X T/A X Y
3.45 3.35 3.45 3.35 3.45 0.83 X 3.35
T/PA c-a 2.56
1.00 Y 0.32 0.44 T 0.32
2S3(x,y) T/PA
Y A
T 0.47
B 2.15 2.07
B B X A A
CISTERNA 1.11 0.45
1.48 0.47
0.60 1.84 0.60 0.20 0.95
X 0.44 1.53 0.86 X

2S (a,b)
T/A T
1.70 2' 0.91 0.91 2' 2'

3
T T

c-a
B A A
X
T 1.50 T 0.47 0.45 0.45
c-a

c-a

c-a

c-a

c-a

c-a

c-a

c-a

c-a
0.48 0.48 2S3(a,x) A B A 2S3(a,x) B B T
T/A S3(x)
C2 3.08 0.10 C2 0.10 C2 0.10
2 C1 C1 C1 0.33 2 2 C1 C1 C1 2 2 C1 C1 0.59 1.82 0.48
C1 2
2.56

c-a

c-a
c-a

c-a
c-a

c-a

c-a

c-a

c-a

c-a
Y T/A
0.74 S(z) S(x) 0.80
B B 1.74 1.60 T

2S(x,y)
1.00 T
T
1.26 1.13
X X 2.07 Z
0.75 1.53 0.63 0.32 X X
T/A
1.20 0.80
T 0.30 1.20 0.80
1.50 0.10 T c-b
2S(x,y)
T
1.08 1.09 B A A
1.25 1.05 B B
X X

2S3(a,b)
3.15 Y 3.15 3.15 3.15 3.15 0.60 3.15
X 0.65
0.78 1.84 0.48
S(y)
2.90 X X
X X A A M - 2.90x2.80m M - 1.80x2.80m
2S3(a,b)
B B
1.40x2.80m

c-a
2 S(x) c-a

2S(a,b)
S(y)
1.41 c-b
Y
0.60 1.82 0.60 0.80 T/PA 0.40
T/PA
2S (a,b) 0.10 T Y 0.70 0.54
1.44 2S(x,y)
T/PA
3S(x,y,z) S(x) X X
PL1

PL1
0.44

c-a

c-a
Y T
c-a

c-a

c-a

c-a

c-a

c-a
1 2 z
0.22 Y Y
M - 2.65x2.80m
0.59 1.82 0.65 0.60
0.52 0.49 1.84 0.47
c-x

c-x

c-x

c-x
C1 C1 C1 C1 C1 C1 C1 C1c-a c-a C1 C1

c-a
1
1 1 1 1 1 1

c-a

c-a

c-a
wh
0.40 0.40
X X
0.44 T/PA
A A X X
0.40 0.40
0.75 1.84 0.48 1.84

3.32 2.20 3.42 3.32 2.20 3.42


3.32 2.31 3.29
8.94 8.94
8.94
A B C D A B C D
A B C D

PLANTA 1º PISO PLANTA 2º PISO PLANTA 3º PISO


A B C D
8.94
3.32 2.20 3.42
1.43 0.92

5 c-a c-a c-a 5


c-a

C1 T/PA C1
c-a

B 0.59
1.35 0.91 .40
A

2.15
T/PA
2.15
DETALLE DEL CALCULO DE CARGAS TG
DIAGRAMA UNIFILAR T.G-1D .05
CUADRO DE CARGAS DEL SISTEMA
A
.30 .20 .40 DISTRIBUCIÓN DEL ÁREA DE VIVIENDA 3°. PISO Y AZOTEA
C-1 ALUMBRADO 1ER. PISO LEYENDA
C-2 B AREA X CARGA P.I. M.D.
ALUMBRADO 1ER. PISO .05 DESCRIPCION
(m2 x w/m2) (w)
FACTOR DE DEMANDA (%)
(w)
c-a

2.52 M1
4 A 4 DIAGRAMA 1ER PISO C-3 ALUMBRADO 1ER. PISO 249.29 x 25 6,330.00 2 000.00 X 1.00 2 000.00
c-b

c-a
c-b

wh TG1-C - ALUMBRADO
C2
C3
C1

C2 C2 C1 MEDIDOR 4 - ÁREA COMÚN2 x


25 TABLERO DE DISTRIBUCION
1.80 ESPECIAL C 4,232.25X 0.40 1,692.90
A C-4 TOMACORRIENTE 1ER. PISO TD Borde Sup - OTRAS CARGAS 80 x 5 400.00
2 x6 mm2 TW+1x6 (T)mm2 TW 400.00
c-a

A
0.10
c-a

25mm Ø PVC - P ESPECIAL .15 .30 .15


1.22 TG-04 2 x 25 A C-5 wh CONTADOR DE ENERGIA 1.80 - 01 ELECTROBOMBA 1 500.00 100% 1 500.00
30 mA
S.T.D.-1(2do. Piso) TECHO OCT-100x40 ESC. S/E
C-6 SALIDA PARA CENTRO DE ALUMBRADO EN TECHO - 01 THERMA 1 500.00 100% 1 500.00
BORNERA PARA CONEXION
1.50 DE PUESTA A TIERRA
S.T.D.-1(3er. Piso) TECHO ESPECIAL CONDUCTOR DESNUDO
2S(a,b) C-7
SALIDA DE ALUMBRADO DICLOICO DE TECHO(12 SMD) 9,730.00 6,692.90
D/T
c-a CONECTOR DE BRONCE
S.T.D.-1(Azotea)
2.65 T/PA 2.65 C-8 SALIDA PARA ALUMBRADO EN PARED (BRAQUETE)
2.20 OCT-100x40
RESERVA ELECTRODO DE COBRE
T/PA
TECHO ESPECIAL .10
SALIDA PARA CENTRO DE ALUMBRADO COLGANTE

1.14 2.71 ESPECIFICACIONES TECNICAS


DIAGRAMA UNIFILAR S.T.D-1 PISCINA ESPECIAL
0.83 DIAGRAMA 2DO PISO D
SALIDA DE ALUMBRADO DICLOICO DE ACUÁTICA
DETALLE DE MEDIDOR
S(a) C-1 ALUMBRADO 2DO. PISO
STD-1 2DO. PISO
c-e
c-a

c-a

SALIDA PARA ALUMBRADO LINEAL LUCES PUNTUALES TECHO ESPECIAL SERAN DE COBRE ELECTROLITICO DE 99.9 % DE CONDUCTIBILIDAD ELECTRICA ;
2S(a,b)
y ALUMBRADO 2DO. PISO TENDRAN AISLAMIENTO TERMOPLASTICO TIPO TW-600 V. PARA ALIMENTADORES ,
0.64 C-2

3 C1 S(y) C1 C1 3 STD-1 C-3 T/A


SALIDA PARA TOMACORRIENTE ALTO 1.80
RECT.
100x55x50mm
CIRCUITOS DERIVADOS DE ALUMBRADO Y TOMACORRIENTES, SIENDO EL
2x ALUMBRADO 2DO. PISO CONDUCTOR MINIMO A UTILIZARSE EL 2.5mm² .
25
c-a
c-a

c-a

A
2 x6 mm2 TW+1x6 (T)mm2 TW RECT.
C-4 SALIDA PARA TOMACORRIENTE MONOF. DOBLE CON LINEA A TIERRA 0.40 / 1.10
A 25mm Ø PVC - P TOMACORRIENTE AZOTEA T T 100x55x50mm Circuitos de
2 x 25 A
MONOFASICO
Iluminacion SERAN DEL TIPO PVC - SEL ( STANDAR EUROPEO LIVIANO ); PARA EL SISTEMA
T/PA 30 mA C-5 SALIDA PARA TOMACORRIENTE A PRUEBA DE HUMEDAD CON
1.10
RECT.
RESERVA DE ALUMBRADO , TOMACORRIENTES Y COMUNICACIONES.
T/PA LINEA A TIERRA 100x55x50mm MEDIDOR
BORNERA PARA CONEXION
- DEL TIPO PVC - SAP ( STANDAR AMERICANO PESADO ); PARA EL ALIMENTADOR
RECT.
11.40 11.40 DE PUESTA A TIERRA S 2S 3S SALIDA PARA INTERRUPTOR DE UNO, DOS Y TRES GOLPES
1.40
100x55x50mm
2.50 PRINCIPAL Y EN ZONAS DONDE SE INDIQUE EN PLANO.

2.12 DIAGRAMA 3ER PISO DIAGRAMA UNIFILAR S.T.D-1 S3 2S 3 SALIDA PARA INTERRUPTOR DE CONMUTACION SIMPLE Y DOBLE
1.40 RECT.
100x55x50mm
SERAN DE Fº Gº DE 1.5 mm DE ESPESOR DE PLANCHA, PARA TODAS LAS SALIDAS
STD-1 2DO. PISO CUAD. Circuitos de
2x ALUMBRADO 3ER. PISO SALIDA PARA CAJA DE PASE CUADRADA CON TAPA 0.40
Tomacorrientes PROYECTADAS EN PLANO.
C-1 100x100x40mm
1.01 2 x6 mm2 TW+1x6 (T)mm2 TW
25
A

3.45 2.38 3.35 25mm Ø PVC - P ALUMBRADO 3ER. PISO SALIDA DE FUERZA 0.40 CUAD-100x55
C-2
2.00 1.80
SERAN DEL TIPO PARA EMPOTRAR EN MUROS EQUIPADO CON INTERRUPTORES
T/PA STD-1 C-3 DEL TIPO NO FUSE TERMOMAGNETICOS CON CAP. DE RUPTURA DE 10 KV. EN 220 VAC.
ALUMBRADO 3ER.PISO SUELO
POZO DE PUESTA A TIERRA (VER DETALLE EN PLANO)
BORNERA PARA CONEXION - LOS INTERRUPTORES DEBERAN TENER CONTACTOS DE PRESION ACCIONADOS
T/PA DE PUESTA A TIERRA
Conexion
C-4 TOMACORRIENTE AZOTEA POR TORNILLOS PARA RECIBIR LOS CONDUCTORES.
2 x 25 A NUMERO DE CONDUCTORES Domiciliaria - EL INTERRUPTOR DIFERENCIAL DEBE SER DE 30 mA-220V, SERA DEL MISMO TIPO
30 mA C-5
RESERVA 1.00 Y MODELO DEL INTERRUPTOR .
CONDUCTOR PARA TIERRA
A 0.98 B - LOS TABLEROS ESTARAN PROVISTOS DE BARRA DE PUESTA A TIERRA , PUERTA ,
2' .80 CHAPA Y LLAVE.
c-a

CONDUCTO EMBUTIDO EN TECHO O PARED PVC-L CENTROS DE LUZ


DIAGRAMA AZOTEA DIAGRAMA UNIFILAR S.T.D-1
c-a

c-a

c-a

CONDUCTO EMBUTIDO EN PISO O PARED PVC-P TOMACORRIENTES


STD-1 2DO. PISO DEBERAN SER DEL TIPO PARA ACEPTAR ENCHUFES TANTO CHATOS
2.67 c-j c-i C2 0.10 STD-1
2 C1 C1 C1 2 2x
25
C-1 ALUMBRADO AZOTEA CONDUCTO EMBUTIDO EN PISO O PARED PARA RED PRINCIPAL PVC-P
AMERICANOS COMO REDONDOS EUROPEOS 15 A - 220 V. SIMILAR A SERIE MAGIC
DE TICINO CON PLACAS DE ALUMINIO ANODIZADO.
A
S(x) 2 x6 mm2 TW+1x6 (T)mm2 TW
c-a

c-a

X C-2 TOMACORRIENTE AZOTEA


25mm Ø PVC - P INTERRUPTOR DIFERENCIAL : DE CAPACIDAD : Indicada
2.00 2.00 2 x 25 A DE SENSIBILIDAD : 30 mA
ESPECIFICACIONES TECNICAS
30 mA C-3 SERAN DEL TIPO BALANCIN OPERACION SILENCIOSA DE 5 A - 220 V. PARA
1.08 1.08 RESERVA POZO DE TIERRA INTERRUPTORES DE UN GOLPE Y DE 10 A -220 V. PARA INTERRUPTORES
BORNERA PARA CONEXION 1. LAS TUBERIAS SERAN DE PVC LIVIANO, SALVO INDICACION Y EL DIAMETRO MINIMO SERA DE
DE PUESTA A TIERRA DE DOS Y TRES GOLPES. SIMILAR A SERIE MAGIC TICINO.
1.39 15 mm.
2. LOS CONDUCTORES SERAN DE COBRE ELECTROLITICO CON AISLAMIENTO TW Y SECCION EN
T/PA mm². LA MINIMA SERA DE 2.5 mm² SALVO INDICACION. LAS TUBERIAS QUE VAYAN INSTALADAS POR JARDIN, IRAN EMPOTRADAS A 0.30m. DE
3. EL TABLERO GENERAL SERA GABINETE METALICO DE EMPOTRAR CON INTERRUPTORES PROFUNDIDAD E IRAN PROTEGIDAS CON DADO DE CONCRETO DE 0.10 m.
AUTOMATICOS TERMOMAGNETICOS.
A B T/PA TODO LO REFERENTE A LA EJECUCION DE LAS INSTALACIONES,CALIDAD Y CARACT. DE
3.15 3.15 4. LAS CAJAS SERAN DE F°G° DEL TIPO PESADO.
LOS MATERIALES A UTILIZARSE EN EL PROYECTO, DEBERAN CUMPLIR LO ESTABLECIDO
0.55 RECTANGULAR: 100 x 55 x 50 mm EN EL CODIGO NACIONAL DE ELECTRICIDAD -UTILIZACION 2006 Y RNE.
OCTOGONAL: 100 x 40 mm
CUADRADO: 100 x 40 mm
NOTA. Colocar Tomacorriente alto para extractor de aire Altura: 210 ver
1.60 en planos especiales Lámina IE- 02

1 1

3.32 2.31 3.29

8.94
A B C D

Proyecto: Especialidad: Proyectista: Propietario:

PLANTA AZOTEA INSTALACIONES ELECTRICAS


ING. ROJAS SOTO AMPARO HELEN CECILIA
Plano: VELENZUELA ROMANO
LUMINARIAS - TOMACORRIENTE
VIVIENDA DNI: 46870329
UNIFAMILIAR
Ubicación: Escala:
SECTOR LOS PATOS - URB ESTANCIA DE SANTA MARIA V INDICADA
MZ "B5" - LT 29 - AV ALAMEDA CENTRAL
OCTUBRE - 2023
IE:01
DISTRITO, PROVINCIA Y DEPARTAMENTO DE ICA

You might also like