CardioTechTM

BP3T Blood Pressure Monitor

User Manual
Arm Type

MEM

SET

Thank you for purchasing this Ozeri Blood Pressure Monitor. Please read this
manual thoroughly before first use, and keep this manual handy for future
6755 Mira Mesa Blvd. reference.
Suite 123-239
San Diego, CA 92121
sales@ozeri.com
TABLE OF CONTENTS TABLE OF CONTENTS

Before Using Your Blood Pressure Monitor Technical Information


Introduction 4 Specifications 24
Important Safety Information 5 Accessories 25
Health and Blood Pressure Values 8 FCC Statement 26
Suggestions Before Measuring 9 Warranty 31
Customer Support 33
Getting to Know Your Unit
LCD Full Display 10
Device Components & Control Button Descriptions 11
Device and Control Button Descriptions 12
Battery Installation/Replacement 12
AC Power 12
Programming the Unit 13

Operating Instructions
Applying the Arm Cuff and Positioning 15
Measuring Your Blood Pressure 16
About Blood Circulation and Pressure 17
Irregular Heart Beat? 18
What is Arrhythmia? 19
Recalling Records 20
Deleting Records 21
Troubleshooting the Unit 22
Maintenance 23

2 3
INTRODUCTION IMPORTANT SAFETY INFORMATION

Thank you for purchasing the Ozeri BP3T Fully Automatic To ensure the correct use of this product, basic safety
Blood Pressure Monitor. This device uses the oscillometric measures should always be followed. Read all information
method of blood pressure measurement which detects the in the instruction manual and any other literature included in
movement of blood through your brachial artery, and the box before using this device, and observe all Warnings
converts your blood pressure into a digital reading. The unit and Cautions.
is simple to use because no stethoscope is needed while
using an oscillometric monitor. This device automatically Warnings
stores 60 sets of 2 measurement values with date and time The following are warnings of potentially hazardous
data for 2 users (120 measurements total). You can access situations which, if not avoided, could result in death or
the stored data simply by pressing the MEM button. serious injury:

The BP3T Monitor includes the following items: ● DO NOT confuse self-monitoring with self-diagnosis. This
● Monitor unit allows you to monitor your blood pressure. Contact
● Cuff your physician for specific information about your blood
● Instruction manual printed in English pressure. Self-diagnosis and treatment using measured
● Carrying bag results may be dangerous. Follow the instructions of your
● 4 AAA batteries physician or licensed healthcare provider.
● Consult your physician before measuring blood pressure,
especially if you have any of the following conditions:
Hypertension, Diabetes, Arteriosclerosis, Kidney or
Vascular Disease, or any conditions affecting circulation.
● DO NOT adjust medication based on measurement results
from this blood pressure monitor. Take medication as
prescribed by your physician. Only a physician is qualified
to diagnose and treat High Blood Pressure.
● The monitor is not intended to be a diagnostic device.

4 5
IMPORTANT SAFETY INFORMATION (CONTINUATION) IMPORTANT SAFETY INFORMATION (CONTINUATION)
BEFORE YOU START

● This device is intended for use in measuring blood ● Operate this device only as it is intended. Do not use this
pressure and heart rates for adults only. Do not use on device for any other purpose.
infants or persons who cannot express their intentions. ● Do not use a cellular phone near this device. Cell phones
● This unit is not suitable for continuous monitoring during may inhibit the accuracy of this device.
medical emergencies or operations. ● Do not disassemble or attempt to repair this device or any
● The equipment is not AP/APG equipment and not suitable of its components. Doing so will void the warranty.
for use in the presence of a flammable anesthetic mixture ● Do not use this device where flammable gases (such as
with air, oxygen, or nitrous oxide. anesthetic gas, oxygen or hydrogen) or flammable liquids
● If battery fluid should get in your eyes, immediately rinse (such as alcohol) are present.
with plenty of clean water. Contact a physician ● This device is intended for non-invasive measuring and
immediately. monitoring of arterial blood pressure. It is not intended for
use on extremities other than the upper arm or for
Precautions functions other than obtaining a blood pressure
The following are Precautions of potentially hazardous measurement.
situations which, if not avoided, may result in minor or ● If you are taking medication, consult your physician to
moderate injury to the user or patient or damage to the determine the most appropriate time to measure your
equipment or other property: blood pressure.
● If the cuff pressure exceeds 40 kPa (300 mmHg),the unit
● Read all of the information in the instruction manual and will automatically deflate. Should the cuff not deflate when
any other literature in the box before operating the unit. pressures exceeds 40 kPa (300 mmHg), detach the cuff
● Dispose of the device, components and optional from the wrist and press the stop button to stop inflation.
accessories according to applicable local regulations.
Unlawful disposal may cause environmental pollution.
● Use only Ozeri authorized parts and accessories. Parts
and accessories not approved for use with the device may
damage the unit.

6 7
HEALTH AND BLOOD PRESSURE VALUES SUGGESTIONS BEFORE MEASURING

What is the standard blood pressure classification? 1. Rest for at least 5-10 minutes before taking your blood
This device refers to a blood pressure classification pressure.
developed by The World Health Organization (WHO) and 2. Avoid eating, smoking, exercising, bathing and drinking
the International Society of Hypertension (ISH). (especially alcohol, caffeine or tea) for at least 20-30
Diastolic Blood Pressur (mmHg) minutes before taking a measurement, and avoid talking
Severe hypertension while measuring your blood pressure.
110
Moderate hypertension
3. Make sure the wrist cuff is at heart level.
100 4. Stress raises blood pressure. Try to keep calm before
Mild hypertension
90 and during the measurement process.
Normal systolic value
85 5. Avoid a very cold environment.
Normal blood pressure
80
Optimal
6. Use the bathroom before taking measurement.
blood pressure
(target value)
7. Avoid excessive talking and hand movement.
120 130 140 160 180 Systolic Blood Pressure (mmHg)
8. Wait at least 20 min after taking bath or shower.
9. Wait 2-3 minutes before retaking your blood pressure
Your monitor will display the blood pressure classifications measurement.
as shown in the table below: 10. Keep the records for your physician and refer to your
physician for guidance. Remember that one reading
Blood
Level
does not provide a true blood pressure value; only
Pressure
(mmHg) long-term records will reveal a more accurate picture
130~139
SYS <120 120~129 140~159 160~179 >180
of your blood pressure. Try to take your
DIA 80~84 85~89 90~99 100~109
<80 >110
measurement at the same time each day to stay
consistent.
CAUTION
Only a physician can tell you your normal blood pressure range
and the point at which you are at risk. If the measurements taken
with this product consistently fall outside your normal range,
consult your physician for further testing.

8 9
LCD FULL DISPLAY DEVICE COMPONENTS & CONTROL BUTTON DESCRIPTIONS

CUFF

AIR HOSE

AIR CONNECTOR PLUG


SYMBOL DESCRIPTION EXPLANATION
Higher blood pressure produced by USER SELECT SWITCH
Systolic blood pressure
heart’s contraction
Diastolic blood pressure Lower blood pressure produced by
heart’s relaxation
Pulse Pulse per minute MEM

AC power socket
Deflating Cuff air is deflating
MEM/UP
Time (hour:minute) Currently time TOUCH KEY
START/OFF BUTTON
Memory Displays measurements stored in memory
LCD DISPLAY SET/DOWN TOUCH KEY
Measured unit of blood pressure
mmHg
(1mmHg=0.133kPa)

kPa Measured unit of blood pressure BATTERY COMPARTMENT


(1kPa=7.5mmHg)

Low battery Batteries are low and need to be replaced


Movement Detected Movements will result in inaccurate results

Average Average values of blood pressure and pulse

Recall Mode Recorded values are being displayed

Arrhythmia Irregular heartbeat


User A User A is active

User B User B is active


Blood Pressure Health Blood pressure classifications according to
the World Health Organization

10 11
BATTERY INSTALLATION / REPLACEMENT PROGRAMMING THE UNIT

To prevent the accidental


Setting Date, Time and Measurement
deletion of user programmed
settings and of the blood It is important to set the date and time before using your
pressure readings stored in blood pressure monitor, so that a time stamp can be
memory, please make sure that the device is turned off assigned to each record that is stored in the memory.
before installing or replacing the batteries.
1.With the unit off,
Use 4 “AAA” 1.5V Alkaline batteries only. Do not use other
press and hold the
types of batteries as this may damage the unit.
“SET” button for 3 START
Install the batteries as follows: STOP
seconds until the
1. Slide battery cover in direction of arrow to remove it. [YEAR] begins to
2. Install 4 “AAA” size batteries so that the + (positive) and flash.
– (negative) polarities match the polarities as indicated
in the battery compartment. Note: If you are programming the unit for the first time, the unit
3. Replace the battery cover. Replace the batteries when any of the following occur: will automatically enter programming mode once the batteries
The shows are inserted.
The display dims
The display does not light up
AC POWER 2.Press the “MEM”
button to advance
This unit has an optional AC Power Adapter the [YEAR] by START
which is available as an accessory. Use AC increments of one. STOP

Adaptor model UE08WCP-060100SPA The [YEAR] year


only! Pictured at right is where the optional can be set between
2000 and 2050.
AC adaptor plugs in. MEM

CAUTION 3.Once the correct


year has been
To get the best performance and to protect your monitor please selected, Press the START
use the correct batteries or power adapter. “SET” button to
STOP

Remove and store the batteries if this device will not be used for
save it. The unit will
an extended period of time (i.e., 3 months). The batteries can leak
successively
chemicals which can destroy electronic components in this device.
continue on to
Old batteries are harmful to the environment, so please dispose of
setting the date,
properly and follow your local recycling guidelines.
time, and units.

12 13
PROGRAMMING THE UNIT (CONTINUATION) APPLYING THE ARM CUFF AND POSITIONING

4.Repeat steps 2 and 3 to set the [Month] and [Day] Applying the cuff to your left arm
1.Make sure the air plug is securely
inserted into the main unit.
START START
STOP STOP

2.Apply the cuff to your upper left arm,


with the tube running downward along
START START your inner forearm. The base of the
STOP
cuff should be approximately 1”
STOP

above your elbow.


5. Next choose the time format of 12 or 24 hour . Press "MEM" to
change the time format. Press "SET" to confirm the time format. 3.The cuff should be snug but not tight.
You should be able to insert one
6.Repeat steps 2 and 3 to set the [Hour] and [Second] finger between the cuff and your arm.
4.Sit comfortably with your arm resting
START 1’ (2~3cm)
on a flat surface and the cuff level
START
STOP STOP

with your heart.


Note: Be careful not rest arm on air
START START
hose as this could restrict the units
STOP STOP airflow.
Applying the cuff to your
7.Repeat steps 2 and 3 to set the [Unit of Measurement] right arm
The default used unit of measurement in the USA is mmHg. You may also use your right arm for
measurement if you are unable to use
START START your left. The application of the cuff
STOP STOP
follows the same procedure as for the
left arm.
Note 1: It is important that you consistently use the same arm for
8.After the unit has been set it will measurements.
display the picture at right and
then turn off automatically. Note 2: This device features an angled LCD screen. If the LCD
screen is difficult to read while resting on the table, it may be that the
device is too far away or too close to you. Simply move the unit
forward or backward to adjust the viewing angle.
9.To restart the programming again, press and hold the "SET”
button for 3 seconds and continue with step 1.

14 15
MEASURING YOUR BLOOD PRESSURE ABOUT BLOOD CIRCULATION AND PRESSURE

START
1.Press the STOP to turn on the monitor. START
The unit will begin the entire measurement STOP Blood circulation is responsible for supplying the body with
automatically during which it will cycle through oxygen from the lungs. During each heartbeat cycle, the blood
the following screen displays: pressure exerted on the arteries varies between a maximum
(systolic) and a minimum (diastolic) pressure.

The systolic blood pressure value (higher pressure or top


LCD display value) represents the blood pressure produced by the heart
muscle when it contracts and pumps the blood out of the heart.

Unit is automatically
The diastolic blood pressure value (lower pressure or lower
performing a zero
adjustment in preparation
value) represents the blood pressure produced in between
for measurement. heartbeats when the heart muscle relaxes.

Systolic Blood Pressure Diastolic Blood Pressure


Inflating and measuring
automatically. Contraction of Relaxation of the
the heart muscle heart muscle

Blood outflow Blood returns to heart

Pressure increased Pressure decreased


on arteries on arteries
Display and save the Higher pressure Lower pressure
results automatically.

START
2.Press the STOP to power off
START
the monitor. The unit will also
STOP
turn off after 1 minute of
inactivity.

16 17
IRREGULAR HEARTBEAT? WHAT IS ARRHYTHMIA?

An irregular heartbeat is defined as a heartbeat that A heartbeat is stimulated by electrical signals that cause
varies by 25% from the average of all heartbeat intervals the heart to contract. Arrhythmia is a condition where the
while the unit is measuring the systolic and diastolic blood
heartbeat rhythm is abnormal due to flaws in the
pressure.
bio-electrical system that drives the heartbeat. Typical
symptoms are skipped heartbeats, premature contraction,
an abnormally rapid (tachycardia) or slow (bradycardia)
pulse. This can be caused by heart disease, aging,
physical predisposition, stress, lack of sleep, fatigue etc.
The appearance of an irregular heartbeat symbol does
If an irregular rhythm is detected more than twice during
indicate arrhythmia. Arrhythmia and other heart conditions
measurement, the irregular heartbeat symbol with three
hearts will appear on the display along with the can only be properly diagnosed by a doctor through a
measurement results. medical examination.
Irregular
Heartbeat
Symbol

Note: If the irregular heartbeat symbol appears on the


screen, it is recommended you consult your physician for
further testing. Do not use this device as a substitute for
proper medical diagnosis and check-ups by your
physician.

18 19
RECALLING RECORDS DELETING RECORDS

1.With the monitor turned off, select user The following procedure will delete all records for a user.
A or B, and then briefly press the
“MEM” button to show the average of 1.With the monitor
the record. turned off, select
user A or B.
The “AVG” sign will MEM Press and hold
show in the right “MEM” for 3 seconds
corner, Indicating that until the display at
the average recorded right appears.
values of Systolic,
Diastolic, and Pulse
rate are displayed 2.If you do not want to delete the
records, press START
STOP
to escape.
2.Press the
“MEM” or “SET” UP
button to scroll Otherwise, press
up or down “SET” to confirm
through the DOWN
deleting and the
records. monitor will turn
off automatically.
The the record,
date, and time
will display Second of eight The corresponding The corresponding
alternately in records. date is October 11th. time is 10:38.
the lower right
corner of the 3.When the user’s
screen. record is empty the
display at right will
CAUTION show.
The most recent record is shown first. Each new measurement is
assigned to the first record. All other records are pushed back one
digit (e.g., 2 becomes 3, and so on), and the last record (60) is
dropped from the list.

20 21
TROUBLESHOOTING THE UNIT MAINTENANCE

The following table includes a list of error messages and In order to get the best performance and to maximize the life
the possible causes and solutions for problems you may of your unit please review the following tips:
encounter with your blood pressure monitor. If the product
is not operating as you think it should, please check here
before arranging for servicing.

PROBLEM INDICATION CAUSE REMEDY

No power
Display is dim or
will not light up.
Batteries are dead.

Batteries are inserted


incorrectly.
Replace with new batteries.

Insert the batteries


correctly.
X
Low Low battery Batteries are low. Replace with new batteries.
MEM

batteries symbol on screen

M
EM
The cuff is not secured Refasten the cuff and then
E1 properly. measure again. Store in a dry cool place and Do not drop or shake the unit,
Secure the air plug into avoid direct sunshine. and do not store objects on the unit.
Air plug disconnected.
the main unit.
E2 The cuff over inflated. Refasten the cuff and
then measure again.

E3 The cuff pressure is Relax for a moment


excessive. and then measure again.

Error E4 The monitor detected Movement can affect the MEM

massage motion while measuring. measurement.Relax for a MEM

moment and then


measure again.
Only use a clean dry cloth to wipe Avoid dusty and unstable
Eexx A calibration error Relax and retake the the unit. Do not use a damp temperature environments
occurred. measurement. If the or wet cloth
problem persists,
contact
support@ozeri.com for
further assistance. Refer
to the warranty for
contact information and
return instructions.

22 23
SPECIFICATIONS ACCESSORIES

Model BP3T Included in Box: Optional Components:


4 “AAA” alkaline batteries, or optional
Power Supply AC adaptor: 100-240V~, 50-60HZ,400mA
(Use AC Adaptor model
UE08WCP-060100SPA only! )

Display Digital LCD V.A. 5”(w) x 2”(h)) (125mm x 50mm)

Measurement Method Oscillographic method


Inflation Automatic by electric pump

Deflation Automatic pressure release valve

Measurement Range Pressure: 0~300mmHg(0~40kPa)


Pulse value:(40~199)times/minute

Accuracy Pressure:
15oC~25oCwithin±0.4kpa(3mmHg)
Adapter
10oC~40oC(out of 15oC~25oC) Type:UE08WCP-060100SPA
within ±0.8kpa (6mmHg) Input:100~240V,50~60Hz,400mA
Pulse value: ±5% Output:6V 1A

Operating Temperature / Temperature: 40oF ~ 104oF (10oC~40oC)


Humidity Relative humidity ≤80%
Contact Information
Storage & Transportation Temperature: -4oF ~ 140oF (-20oC~60oC)
Ozeri Customer Service
Temperature/Humidity Relative humidity:10%~93%
Customer service: 1-877-299-1296 or
Fits arm circumferences Email: support@ozeri.com
Arm Cuff Size 8.7" to 14.2" (22cm to 36cm) (OzeriTM and its subsidiaries assume no liability for damage caused by
Main Unit Weight Approx. 10.6 oz. (300g) excluding batteries
the use of the Ozeri Blood Pressure Monitor other than for its intended
use or as instructed above and in the User Manual.)
Main Unit External Approx. 7” (l) x 4” (w) x 1 ½ “ (h)
Dimensions (180mm x 100mm x 39mm)

Memory Up to 60 measurements per user

Note: These specification are subject to change without notice.


24 25
FCC STATEMENT FCC STATEMENT

Guidance and manufacturer’s declaration – electromagnetic emissions Immunity test IEC 60601 Compliance level Electromagnetic environment –
test level guidance
The BP3T is intended for use in the electromagnetic environment specified Electrostatic ± (2, 4, 6) ± (2, 4, 6) kV Floors should be wood,
below. The customer or the user of the BP3T should assure that it is used in discharge (ESD) kV contact contact concrete or ceramic tile. If floors
such an environment. ± (2, 4, 8) ± (2, 4, 8) kV are covered with synthetic
IEC 61000-4-2 kV air air material, the relative humidity
Emissions Compliance should be at least 30 %
Electromagnetic environment - guidance
test
Electrical fast ±2 kV for Not applicable Main power quality should be
The BP3T uses RF energy only for its internal transient/burst power that of a typical commercial or
RF emissions hospital environment.
function. Therefore, its RF emissions are very low
Group 1 IEC 61000-4-4 supply lines
and are not likely to cause any interference in nearby
CISPR 11 ±1 kV for
electronic equipment.
input/output
RF emissions lines
Class B ±1 kV
CISPR 11 Surge Not applicable Main power quality should be
differential that of a typical commercial or
Harmonic IEC 61000-4-5 mode hospital environment.
emissions ±2 kV common
Not applicable mode
The BP3T is suitable for use in all establishments,
including domestic establishments. Voltage dips, <5 % UT Not applicable Main power quality should be
IEC 61000-3-2
short (>95 % dip in that of a typical commercial or
Voltage interruptions and UT) hospital environment. If the user
fluctuations / voltage variations for 0,5 cycle of the BP3T requires continued
flicker emissions Not applicable on power supply operation during power mains
input lines 40 % UT interruptions, it is recommended
IEC 61000-3-3 (60 % dip in UT) that the BP3T be powered from
IEC 61000-4-11 for 5 cycles an uninterruptible power supply
or a battery.
70 % UT
Guidance and manufacturer’s declaration – electromagnetic immunity (30 % dip in UT)
for 25 cycles
The BP3T is intended for use in the electromagnetic environment specified below.
The customer or the user of the BP3T should assure that it is used in such an <5 % UT
(>95 % dip in
environment.
UT)
for 5 sec
Power frequency 3 A/m 3 A/m Power frequency magnetic
(50/60 Hz) fields should be at levels
magnetic field characteristic of a typical
location in a typical commercial
IEC 61000-4-8 or hospital environment.
NOTE: UT is the a.c. mains voltage prior to application of the test level.
26 27
FCC STATEMENT FCC STATEMENT

Guidance and manufacturer’s declaration – electromagnetic immunity NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation
The BP3T is intended for use in the electromagnetic environment specified is affected by absorption and reflection from structures, objects and people.
below.
The customer or the user of the BP3T should assure that it is used in such an Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio
environment.
broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
Immunity IEC 60601 Compliance Electromagnetic environment – assess the electromagnetic environment due to fixed RF transmitters, an
test test level level guidance electromagnetic site survey should be considered. If the measured field strength in the
Portable and mobile RF communications location in which the BP3T is used exceeds the applicable RF compliance level above,
equipment should be used no closer to the BP3T should be observed to verify normal operation. If abnormal performance is
any part of the BP3T, including cables, observed, additional measures may be necessary, such as reorienting or relocating the
than the recommended separation BP3T.
distance calculated from the equation
applicable to the frequency of the Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3
transmitter. V/m.

Recommended separation distance


d = 1,2 P

Conducted RF 3 Vrms Not applicable d = 1,2 P 80 MHz to 800 MHz


IEC 61000-4-6 150 kHz to d = 2,3 P 800 MHz to 2,5 GHz
80 MHz
Radiated RF 3 V/m where P is the maximum output power
IEC 61000-4-3 3 V/m rating of the transmitter in watts (W)
80 MHz to according to the transmitter manufacturer
2,5 GHz and d is the recommended separation
distance in meters (m).

Field strengths from fixed RF transmitters,


as determined by an electromagnetic site
survey,a should be less than the
compliance level in each frequency
range.b

Interference may occur in the vicinity of


equipment marked with the following
symbol:

28 29
FCC STATEMENT WARRANTY INFORMATION

Recommended separation distances between Your Ozeri Blood Pressure Monitor, excluding the arm
portable and mobile RF communications equipment and the BP3T cuff, is warranted to the original owner for 5 years from the
The BP3T is intended for use in an electromagnetic environment in which date of purchase against defects in material and
radiated RF disturbances are controlled. The customer or the user of the
workmanship under normal use. The arm cuff is warranted
BP3T can help prevent electromagnetic interference by maintaining a
minimum distance between portable and mobile RF communications to the original owner for 1 year to be free from defects in
equipment (transmitters) and the BP3T as recommended below, according to material and workmanship under normal use. Should your
the maximum output power of the communications equipment.
blood pressure monitor and/or arm cuff appear defective
Rated maximum
output power of Separation distance according to frequency of transmitter within the applicable period from the date of purchase,
transmitter
return the defective unit, freight prepaid along with an
W explanation of the claim to Ozeri. Please pack carefully to
Electrical fast 150 kHz to 80 80 MHz to 800 800 MHz to 2,5 avoid damages in transit. Under this warranty, Ozeri will
transient/burst MHz MHz GHz
d = 1,2 P d = 1,2 P d = 2,3 P
repair or replace any parts found to be defective due to a
IEC 61000-4-4
manufacturer’s defect. This warranty extends only to
0.01 0.12 0.12 0.23
personal use and does not extend to any product that has
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
been used for commercial use, or use which is not
10 3.8 3.8 7.3
intended. There are no warranties other than that
100 12 12 23 expressly set forth herein.
For transmitters rated at a maximum output power not listed above, the
recommended separation distance d in meters (m) can be estimated using
the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher
frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic
propagation is affected by absorption and reflection from structures, objects
and people.

30 31
WARRANTY INFORMATION CUSTOMER SUPPORT

This warranty is not transferable. Ozeri is not responsible Ozeri Customer Service
in any way for damages, losses or inconveniences caused Customer service: 1-877-299-1296 or
by equipment failure caused by user negligence, abuse, or Email: support@ozeri.com
use not in accordance with the “User Guide” or any (OzeriTM and its subsidiaries assume no liability for
additional safety, use, or warnings included in the product damage caused by the use of the Ozeri Blood Pressure
materials. Further, Ozeri is not liable for incidental or Monitor other than for its intended use or as instructed
consequential damages of any nature resulting from the above and in the User Manual.)
use of this product and any liability shall not exceed the
purchase price of the product.

This Warranty gives you specific legal rights.


You may also have other rights which vary from state to
state.

THIS WARRANTY DOES NOT APPLY TO THE


FOLLOWING:

• Damage due to accident, misuse, abuse,


alterations or vandalism.
• Improper or inadequate maintenance.
• Unauthorized modification or commercial use.
Ozeri Customer Service
• Damage in return transit.
Customer service: 1-877-299-1296 or
• Unsupervised use by children under 18 years of age.
Email: support@ozeri.com

32 33